Firmware Update Version 0.34, 0.56
Release Notes & Installation Guide
Release Date: 23/12/2015
Compulite Systems (2000) Ltd.
9 Hanagar St. Neve Ne'eman B Industrial Zone Hod Hasharon, 45421, Israel
Tel: 972 9 744 6555 ~ Fax: 972 9 746 6515 ~ www.Compulite.com
Vector Wing 20 Firmware Update V0.34, V0.56
Copyright © 2015 Compulite Systems (2000) Ltd. All rights reserved.
This guide is delivered subject to the following conditions and restrictions:
This product or document is protected by copyright and distributed under
licenses restricting its use, copying, distribution and decompilation. No part of
this product or document may be reproduced in any form by any means without
the prior express written authorization of Compulite Systems (2000) Ltd. and its
licensors (if any). Information contained herein is subject to change without
notice.
1|
Table of Contents
1
Table of Contents
1
Table of Contents ........................................................................... 2
2
Version Highlights .......................................................................... 3
3
Installing Firmware ........................................................................ 4
Getting Started ........................................................................................ 4
|2
Vector Wing 20 Firmware Update V0.34, V0.56
2
Version Highlights
This version includes the following fix:

On Connection to a console, first 2 Playbacks jumped to full.
There are 2 types of Wing 20 panels:
1. Revision A-C.
2. Revision D.
The latest Firmware version for Revision A-C is T024V034.S.
The latest Firmware version for Revision D is T024V056.S.
In order to know which revision you have and get the Firmware version that fits
to your Wing 20 please contact support@compulite.com.
See installing new firmware instructions.
3|
Installing Firmware
3
Installing Firmware
The following procedure is for updating the Firmware on the Vector Wing 20.
Before proceeding please make sure of the following:

An alphanumeric keyboard is attached

An external mouse is connected to the Vector system
ATTENTION!

This update is ONLY for Vector software version 3.20R01 and above.

Make sure to follow the installation instructions in full.

To view the update progress, open the RT monitor by double clicking on the
cog-wheel sign.

If you encounter any problems, please contact your local distributor or
contact the Compulite support team: support@compulite.com
Getting Started
Before installing the Firmware update, please check that you have the
following:

A running and working Vector console or PC with software version 3.20R01
and above. The software version can be viewed from Tools ► RT Status.

The new Firmware file according to your Wing 20 revision (T024V034.S or
T024V056.S)

The Wing 20 needs to be connected via an Ethernet hub to the Vector
network (Data port):
To connect the Wing to the network hub
1. Connect a regular Ethernet cable from the Vector Data port or the
Ethernet port on a Vector PC to the Ethernet hub.
2. Connect a regular Ethernet cable from the Wing 20 to the same Ethernet
hub as the console or vector PC.
To install firmware
1. Save a copy of your show file.
2. Stop any DMX transmission via Ethernet (VC, Art-Net or sACN).
3. Copy the Firmware file to a USB stick or portable device.
Do not run the Firmware update from the USB or portable device!
|4
Vector Wing 20 Firmware Update V0.34, V0.56
4. Copy the Firmware file from the USB or portable device to the Vector
Updates folder:

For Vector console: D:\Program Files\Compulite Vector\Config\Updates

For Vector PC: C:\Program Files\Compulite\ Vector Pc\Config\Updates
5. Make sure the Vector console or Vector PC is ON.
6. From Vectors menu bar click on Tools ► Software Update.
The Update dialog window opens.
7. From the Update dialog box click on the Files of Type drop down list and select
Vector Firmware Files(*.s).
5|
Installing Firmware
8. Select the new Firmware update file (T024V034.S or T024V056.S) and
then click Open to start the Update.
NOTE: Select the new Firmware
version; T024V034.S or T024V056.S
9. The Update will begin and the message “Restarting RT…” will be displayed in
the command line.
The update takes approximately 1 minute. The update progress can be
monitored in the RT window.
Note: Some LED’s on the PC Wing may light up during the update and then
turn off when the update is complete.
Note: If the LED’s do not turn off after a while (2 min or more) then re-load
the firmware file again.
10. When the update is done shutdown the system and re-start the software.
|6