Current/Voltage/Phase Monitors
Gross Automation (877) 268-3700 · www.carlogavazzisales.com · sales@grossautomation.com
MonitControlBro.indd 1
3/13/07 4:12:29 PM
When Technology and Experience Exceed Your Expectations
The standard high-performance DIN-rail housings
Plug-in versions for maximum flexibility
Monitoring is the art of knowledge.
The new compact DIN-rail mount housings
require minimal panel space
If the electrical parameters of the system are in
control, everything runs correctly, reducing down
time and maintenance costs. Our people at Carlo
Gavazzi learned this fundamental lesson through our
thirty years experience designing and manufacturing
monitoring relays. The most sophisticated measuring
techniques, together with the highest attention to make
the unit really easy to set up, make Carlo Gavazzi
Monitoring Relays the optimum solution wherever electrical parameters have to be measured.
The family is available with the same functions in three
different housings: the standard DIN-rail, mount
types, perfect for industrial panels, the Plug-in housing
to allow fast and safe replacement (without rewiring ),
and the new Mini-D housings for DIN-rail mounting,
which can be mounted in electrical panels as well as
in smaller panels for special industrial or non-industrial
applications.
2
Gross
Automation
(877)
268-3700
· www.carlogavazzisales.com
sales@grossautomation.com
Gross
Automation,
1725 South
Johnson
Road, New
Berlin, WI 53146 PH: 262-446-0000,· FAX:
262-446-0300, www.carlogavazzisales.com
MonitControlBro.indd 2
3/13/07 4:13:23 PM
Not all Applications are the
Same... So We are Always
Looking for New Solutions
Our way of developing products always starts from
listening. We begin from the final application, meeting
people to understand the critical issues. We design the
products so that they fulfill or exceed the monitoring
needs, The final result is outstanding performance.
A Guarantee of Reliability by
our Specialized Manufacturing
Centers
Our monitoring relays are manufactured in accordance
to the latest and most reliable techniques and are
100% tested to assure that when the unit is mounted
in the final application it will provide a real sense of
confidence for the user.
Certified Quality
The high quality of production is guaranteed by
the ISO9001 certification of our factory, as well as
continuously testing and improving the production
processes. CE tests, UL and CSA approvals, mean
various independent bodies have tested and approved
the units, a testament to the level of development and
production of our products. Some of them are also
provided with other specific and high demanding
approvals, such as Germanischer Lloyd.
3
Gross
Automation
(877)
268-3700
· www.carlogavazzisales.com
sales@grossautomation.com
Gross
Automation,
1725 South
Johnson
Road, New
Berlin, WI 53146 PH: 262-446-0000,· FAX:
262-446-0300, www.carlogavazzisales.com
MonitControlBro.indd 3
3/13/07 4:13:36 PM
Monitoring Solutions for Water and Pump Applications
Your Automation Challenge
What happens if my pump runs dry? What if the phase
sequence is not correct or one phase fails?
DWB01
Our Product Proposal
• DPA01, PPA01, DPA51: 3-Phase sequence
•
•
•
and loss monitoring relays
DWB01, PWB01: 3-Phase cosϕ monitoring
relays
DWB02, PWB02: 3-Phase active power
monitoring relays
DIB01, PIB01, DIB71: Current relays
Our Solution
DIB71
DPA51
Since it very seldom happens that there is human surveillance of pumps, minor failures may occur as incorrect
phase sequence cause major problems such as flooding. The DPA01, PPA01 and DPA51 detect for the
correct phase sequence and phase loss along with the
voltage regenerated by the pump’s motor; this means that
the maintenance department can easily and promptly be
notified before a system failure occurs.
It is also possible to monitor the load of the pump,
detecting if it is dry or blocked by some material just by
monitoring its electrical values. The DIB01, PIB01 or
DIB71 can be a solution to simply monitor for overloads.
For dry running and overload protection, the DWB01,
PWB01, DWB02 and PWB02 offer full protection.
4
Gross
Automation
(877)
268-3700
· www.carlogavazzisales.com
sales@grossautomation.com
Gross
Automation,
1725 South
Johnson
Road, New
Berlin, WI 53146 PH: 262-446-0000,· FAX:
262-446-0300, www.carlogavazzisales.com
MonitControlBro.indd 4
3/13/07 4:13:40 PM
Monitoring Solutions for Energy Generation Applications
Your Automation Challenge
With an increased use of generators in many applications, it’s absolutely necessary that the mains from the
generator are of high quality to prevent damage to the
connected load(s).
Our Product Proposal
• DPC01, PPC01: 3-phase mains quality relay
• DPC02: 3-phase voltage and frequency
•
monitoring relay
DUA52: Battery level monitoring relay
DPC02
Our Solution
DPC01
DUA52
Carlo Gavazzi’s 3-phase monitoring relays, the
DPC01 and PPC01, can guarantee that the voltage
level af all the phases (even the phase-neutral voltages)
are correct. With the DPC02 the user also knows if the
speed of the generator (that is the frequency of the mains)
is correct. If the generation system is used to sell energy
to the electricity company, the DPC02 can be used
as an interface relay to separate the generator from
the mains if this is required. Finally, the DUA52 can
monitor the voltage level of the start-up battery.
5
Gross
Automation
(877)
268-3700
· www.carlogavazzisales.com
sales@grossautomation.com
Gross
Automation,
1725 South
Johnson
Road, New
Berlin, WI 53146 PH: 262-446-0000,· FAX:
262-446-0300, www.carlogavazzisales.com
MonitControlBro.indd 5
3/13/07 4:14:19 PM
Monitoring Solutions for:
Material Handling Applications
Packaging Applications
Your Automation Challenge
Your Automation Challenge
All industrial applications where sophisticated mechanical machines are used to manufacture, package, mix,
etc. Require high quality mains. A faulty system can
cause poor product quality.
Industrial facilities using advanced technological
machines to optimize the productivity level and the
quality of the end product often need to monitor the
quality of the mains.
DPB01
DIA01
DPB01
DIA53
PPB01
DPB71
Our Solution
Our Solution
Carlo Gavazzi’s DPB01, DPB71 or PPB01 keep the
mains fully monitored, thus preventing dangerous working situations. Furthermore, the most important amperages of the process can easily be monitored by means
of the DIA53 (with transistor output) or the DIB01
(with relay output). These DIN rail mount devices with
their built-in, 12mm current monitoring through-hole, are
capable of measuring up to 100 Amps.
Using the DPB01/PPB01 or the new DPB71 (new
mini DIN-rail mount housing) it is possible to monitor
phase sequence-loss and over-under voltage of the mains
to set up a window comparator system for the mains.
It’s also possible to set an on-delay alarm from 0.1 - 30 sec.
to avoid nuisance tripping and stopping of the machine.
Our Product Proposal
• DIA53 and DIB01: Over current relays
• DIA01 and PIA01: Over current relays
• DPB01 and PPB01, DPB71: 3-phase over and
Our Product Proposal
• DPB01, PPB01 or DPB71: 3-phase over and
under voltage relays
under voltage relays
6
Gross
Automation
(877)
268-3700
· www.carlogavazzisales.com
sales@grossautomation.com
Gross
Automation,
1725 South
Johnson
Road, New
Berlin, WI 53146 PH: 262-446-0000,· FAX:
262-446-0300, www.carlogavazzisales.com
MonitControlBro.indd 6
3/13/07 4:14:42 PM
Monitoring Solutions for:
Elevator/Escalator Applications
HVAC Applications
Your Automation Challenge
Your Automation Challenge
For elevators, escalators and all people moving equipment, the direction of the motion must be 100% correct.
Phase sequence relays are a fast, reliable and easy to
maintain solution. Additionally with an overload, the
motor temperature can damage and eventually destroy
the motor itself.
Correct direction means higher efficiency of the compressor
(in some cases incorrect rotation means immediate breakdown). Furthermore, starting more than one compressor at
the same time can cause a high inrush current with several
problems like EMC noise or low mains voltage.
DTA01
Our Solution
DPA51
DAC51
DAA51
In addition to phase sequence, the DPA51 can detect
the voltage regenerated by the motor in case of phase
loss, which isn’t always detected by less expensive
units. This means that you’ll reduce the risk that your
motor won’t overheat, burn up or cause danger to
people. The DTA01, DTA02, PTA01 and PTA02
thermistor relays measure the temperature inside of
the motor, allowing prompt disconnection in case of
overheating.
Our Product Proposal
• DPA51: 3-phase sequence and phase loss with
•
•
regenerated voltage detection
DTA01: Thermistor relay for motor temperature
protection
DAA51: Multivoltage and multi-range ON delay
timer
Our Solution
DPA51
DPA53
A DAA51 timer is the most flexible solution for the
end user to set the delay times of the compressors. Our
smallest multivoltage phase sequence and loss relay,
the DPA51, prevents an incorrect rotation direction as
well as from single phasing, while the DPA53, with an
undervoltage setpoint, can let the compressor work at its
best. Finally, DAC51, (the smallest star-delta timer on the
market), helps reduce the required panel space.
Our Product Proposal
• DPA51: 3-Phase sequence and loss monitoring relay
• DPA53: 3-Phase sequence and loss monitoring
•
•
relay with undervoltage detection
DAA01, PAA01, DAA51: Delay on operate timers
DAC01, PAC01, DAC51: Star-delta timers
7
Gross
Automation
(877)
268-3700
· www.carlogavazzisales.com
sales@grossautomation.com
Gross
Automation,
1725 South
Johnson
Road, New
Berlin, WI 53146 PH: 262-446-0000,· FAX:
262-446-0300, www.carlogavazzisales.com
MonitControlBro.indd 7
3/13/07 4:14:55 PM
The Easy Way to Find Your Solution
Select your Function Level
Select Your
Measured
Value
Reacts when the
setpoint is eclipsed
or for major failures
(ie. phase sequence or loss)
Adding time delay, more ranges,
TRMS measurement and more
For complete monitoring
Two setpoints
Two relays output
DIA01
PIA01
DIA53*
DIB01 - DIB71*
PIB01 - DIB02
PIB02
DIC01
PIC01
DUA01
PUA01
DUA52*
DUA55*
DUB01 - DUB71*
PUB01 - DUB02
PUB02
DUB03 - PUB03
DPA01 - PPA01
DPA51* - DPA02
PPA02 - DPA53*
DPA51* - DPA55*
DPA71*
DPB01 - DPB71*
PPB01 - DPB02
PPB02
DPC01
PPC01
DPC02
DFB01
PFB01
DFC01
DUC01
PUC01
DTA01 - PTA01
DTA02 - PTA02
DWA01
PWA01
DWB01 - PWB01
DWB02 - PWB02
DWB03 - PWB03
Correct motor rotation
direction, ON/OFF
current monitoring,
motor overtemperature
Monitoring mains
quality, motor overload,
generator speed, pump
dry running
Typical Applications
First letter:
“D” = for DIN-rail;
“P” = for plug-in
* are Mini-D housings
Full mains monitoring,
sophisticated current and
voltage monitoring, full
generator parameters
8
Gross
Automation
(877)
268-3700
· www.carlogavazzisales.com
sales@grossautomation.com
Gross
Automation,
1725 South
Johnson
Road, New
Berlin, WI 53146 PH: 262-446-0000,· FAX:
262-446-0300, www.carlogavazzisales.com
MonitControlBro.indd 8
3/13/07 4:15:04 PM
Some Useful Information to Specify Your Part Number:
How to Determine the Complete Code of the Monitoring Relay You Need
A full part number listing is shown on the next page
The output
-add the code:
The power supply
- add the code:
C
D
724
748
B48
B23
SPDT relay
DPDT relay or
2xSPDT relays
solid state
S
Example:
24 VDC
48 VDC
24 & 48 VAC
115 & 230 VAC
DIA53 S 724 100A
The output add the code:
The power supply
- add the code:
C
D
M44
M23
M48
M60
M69
SPDT relay
DPDT relay or
2xSPDT relays
208
208
380
400
600
to
to
to
to
to
480
240
480
600
690
VAC
VAC
VAC
VAC
VAC
The range - add the code:
5MA
50MA
500MA
5A
10A
20A
50A
100A
150MV
10V
500V
AV0
1, 2 & 5 mA AC/DC
10, 20 & 50 mA AC/DC
100, 200 & 500 mA AC/DC
1, 2 & 5 A AC/DC
10 A AC/DC
20 A AC (DIA53 only)
50 A AC (DIA53 only)
100 A AC (DIA53, DIB01)
60 & 150 mV (DIB02, PIB02)
1, 2, 5 & 10 V AC/DC
20, 50, 200 & 500 V AC/DC
combined ranges
The current range (power relays
only) - add the code:
5A
5 AAC
10A
5 & 10AAC
Example:
DPA53 C M48
The output add the code:
The power supply
- add the code:
The output add the code:
C
D
M24
B48
B23
C
SPDT relay
2xSPDT relays
Example:
24 to 240 VAC
24 & 48 VAC
115 & 230 VAC
DFB01 C M24
SPST relay
2xSPDT relays
Example:
The power supply
- add the code:
724 24 VDC
024 24 VAC
115 115 VAC
230 230 VAC
DTA01 C 115
9
Gross
Automation
(877)
268-3700
· www.carlogavazzisales.com
sales@grossautomation.com
Gross
Automation,
1725 South
Johnson
Road, New
Berlin, WI 53146 PH: 262-446-0000,· FAX:
262-446-0300, www.carlogavazzisales.com
MonitControlBro.indd 9
3/13/07 4:15:11 PM
Our Monitoring Relays Portfolio
Current
DIA01C7245A
DIA01C7485A
DIA01CB485A
DIA01CB235A
DIA53S72420A
DIA53S72420AF
DIA53S72450A
DIA53S72450AF
DIA53S724100A
DIA53S724100AF
DIB01C7245MA
DIB01C7485MA
DIB01CB485MA
DIB01CB235MA
DIB01C72450MA
DIB01C74850MA
DIB01CB4850MA
DIB01CB2350MA
DIB01C724500MA
DIB01C748500MA
DIB01CB48500MA
DIB01CB23500MA
DIB01C7245A
DIB01C7485A
DIB01CB485A
DIB01CB235A
DIB01C72410A
DIB01C74810A
DIB01CB4810A
DIB01CB2310A
DIB02C724150MV
DIB02C748150MV
DIB02CB48150MV
DIB02CB23150MV
DIB71CB235A
DIB71CB235MA
DIB01CM24100A
DIB71CB2350MA
DIB71CB23500MA
DIB71CB485A
DIB71CB485MA
DIB71CB4850MA
DIB71CB48500MA
DIC01D724AV0
DIC01D748AV0
DIC01DB48AV0
DIC01DB23AV0
PIA01C7245A
PIA01C7485A
PIA01CB485A
PIA01CB235A
PIA53S72420A
PIB01C7245MA
PIB01C7485MA
PIB01CB485MA
PIB01CB235MA
PIB01C72450MA
PIB01C74850MA
PIB01CB4850MA
PIB01CB2350MA
PIB01C724500MA
PIB01C748500MA
PIB01CB48500MA
PIB01CB23500MA
PIB01C7245A
PB01C7485A
PIB01CB485A
PIB01CB235A
PIB01C72410A
PIB01C74810A
PIB01CB4810A
PIB01CB2310A
PIB02C724150MV
PIB02C748150MV
PIB02CB48150MV
PIB02CB23150MV
PIC01C724AV0
PIC01C748AV0
PIC01CB48AV0
PIC01CB23AV0
Voltage
3-phase
Power
DUA01C724500V
DUA01C748500V
DUA01CB48500V
DUA01CB23500V
DUA52C724
DUA52C748
DUA55CM44
DUB01C72410V
DUB01C74810V
DUB01CB4810V
DUB01CB2310V
DUB01C724500V
DUB01C748500V
DUB01CB48500V
DUB01CB23500V
DUB03CW24
DUB71CB4810V
DUB71CB2310V
DUB71CB48500V
DUB71CB23500V
DUB02CT23
DUC01D724500V
DUC01D748500V
DUC01DB48500V
DUC01DB23500V
PUA01C724500V
PUA01C748500V
PUA01CB48500V
PUA01CB23500V
PUB01C72410V
PUB01C74810V
PUB01CB4810V
PUB01CB2310V
PUB01C724500V
PUB01C748500V
PUB01CB48500V
PUB01CB23500V
PUB02CT23
PUB03CW24
PUC01C724500V
PUC01C748500V
PUC01CB48500V
DPA01CM44
DPA01CM60
DPA01DM23
DPA01DM48
DPA02CM23
DPA02CM40
DPA51CM44
DPA53CM23
DPA53CM48
DPA55CM44
DPA71DM23
DPA71DM48
DPB01CM23
DPB01CM48
DPB02CM23
DPB02CM48
DPB71CM23
DPB71CM48
DPC01DM23
DPC01DM48
DPC01DM69
DPC01DM23400HZ
DPC01DM48400HZ
DPC01DM49400HZ
DPC01DM69400HZ
DPC02DM23
DPC02DM48
DPC02DM49
DPC02DM69
PPA01CM44
PPA01CM60
PPA01DM23
PPA01DM48
PPA02CM23
PPA02CM40
PPB01CM23
PPB01CM48
PPB02CM23
PPB02CM48
PPC01DM23
PPC01DM48
PPC01DM69
DWA01CM235A
DWA01CM485A
DWB01CM2310A
DB01CM4810A
DWB01CM6910A
DWB02CM2310A
DWB02CM4810A
DWB02CM6910A
DWB03CM2310A
DWB03CM4810A
DWB03CM6910A
PWA01CM235A
PWA01CM485A
PWB01CM2310A
PWB01CM4810A
PWB01CM6910A
PWB02CM2310A
PWB02CM4810A
PWB02CM6910A
PWB03CM2310A
PWB03CM4810A
Frequency
DFB01CM24
DFC01DB48
DFC01DB23
PFB01CM24
Temperature
DTA01C024
DTA01C724
DTA01C115
DTA01C230
DTA02C024
DTA02C724
DTA02C115
DTA02C230
PTA01C024
PTA01C724
PTA01C115
PTA01C230
PTA02C024
PTA02C724
PTA02C115
PTA02C230
10
Gross
Automation
(877)
268-3700
· www.carlogavazzisales.com
sales@grossautomation.com
Gross
Automation,
1725 South
Johnson
Road, New
Berlin, WI 53146 PH: 262-446-0000,· FAX:
262-446-0300, www.carlogavazzisales.com
MonitControlBro.indd 10
3/13/07 11:21:58 PM
Accessories: Current Transformers, Shunts, Sockets
MI
AC current transformers for 5, 20, 100,
500 AAC. Output voltage (0.4-4 Vp) is
proportional to the measured current.
To be used with:
DUA01/PUA01, DIB02/PIB02, DIC01/
PIC01, DWA01/PWA01, DWB01/PWB01,
DWB02/PWB02.
TAD
Cable/bus-bar type current transformers
with DIN-rail/ bus-bar and panel mounting facilities. Rated primary current
from 40A to 4,000A.
To be used with
DIA01/ PIA01, DIB01/PIB01, DWA01/
PWA01, DWB01/PWB01, DWB02/
PWB02.
MP3
3-phase transformers for 5, 20, 100 or
500 AAC. Output voltage (0.4-4 Vp) is
proportional to the highest measured
current.
To be used with:
DUA01/PUA01, DIB02/PIB02, DIC01/
PIC01.
DER
Shunts for DC current in accordance
with DIN-Standard.
Ranges from 1A - 10,000A.
To be used with:
DIB02/ PIB02.
A 82
AC current metering transformer for 25,
50, 100, 250 or 500 AAC. Output current from the transformer is 0-20 mADC
or 4-20 mADC in accordance with IEC
60381. Power supply ON is indicated by
a green LED on the side of the housing.
To be used with:
DIB01/PIB01, DIC01/PIC01 or directly
connected to a PLC.
ZPD11
Socket for mounting on DIN-rail
(DIN EN 0022).
E 82-20
AC current metering transformer with
3 knob selectable ranges. Output from
the transformer is 4-20 mADC in accordance with IEC 60381. Power supply ON
is indicated by a green LED. 12 mm
hole for insulated current carrying wire
makes it suitable for most applications.
For mounting on DIN-rail or directly tp a
back panel with screws.
TADK
1-phase transformers with DIN-rail and
panel mounting facilities. Rated primary
current from 1A to 250A.
To be used with:
DIA01/PIA01, DIB01/PIB01, DWA01/
PWA01, DWB01/PWB01, DWB02/
PWB02.
11
Gross
Automation
(877)
268-3700
· www.carlogavazzisales.com
sales@grossautomation.com
Gross
Automation,
1725 South
Johnson
Road, New
Berlin, WI 53146 PH: 262-446-0000,· FAX:
262-446-0300, www.carlogavazzisales.com
MonitControlBro.indd 11
3/13/07 4:15:29 PM
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising