HP RELAYS HP TYPICAL APPLICATIONS 10 AMP POWER RELAY
HP
Discontinued as of August 31, 2012
10 AMP POWER RELAY
HP RELAYS
TYPICAL APPLICATIONS
Product to be discontinued.
FEATURES
1. High-capacity and long life
Mechanical life is more than 10 million
operations and, with electrical life of more
than 200,000 operations (resistive load
10 A; inductive load 7.5 A), the relay has
excellent inductive load durability.
2. Easy mounting and wiring
The terminal arrangement is apparent at
a glance and wiring is easy. Moreover,
quick tab terminal is also possible.
3. Operation indicator option
Optional operation indicators are
available for easy visual confirmation that
relays are operating. They simplify
maintenance.
4. UL/CSA approved
5. Wide range of sockets and terminal
sockets
To enable use with DIN rails, DIN
terminal sockets are also available.
HP relays enjoy wide use in various
applications, particularly in automation
controls and remote controls.
Applications include:
1. Industrial machinery
For controlling positioning, pressure, and
temperature in molding equipment,
boilers, pumps, charging pressure
equipment, measuring and evaluation
equipment, textile machines, etc.
2. Machine tools
Control of positioning and directional
change in turning machines, lathes,
borers, etc.
3. Food processing packing machines
Automatic control of packing equipment
for milk and seafood, bottling, canning,
and packaging
4. Office equipment
Control of copiers, time recorders, etc.
5. Coin operate machines
Control of food, cigarette, and other
vending machines
6. Measuring devices and equipment
For repeating installation of control
signals and in power amplifiers
7. Generators, transformers and
power receiving equipment.
Functional parts in protective equipment,
functional assistance in automatic
adjustment equipment, telemeters and
other remote monitoring equipment
8. Control of conveyance equipment
Control panels for elevators, escalators,
and other conveyance equipment, control
of all kinds industrial transport equipment
such as conveyors.
9. Amusement equipment
Control of equipment in amusement
parks, etc., control of bowling alley
equipment, control of fountains in public
parks
About Cd-free contacts
We have introduced Cadmium free type
products to reduce Environmental
Hazardous Substances. (The suffix “F”
should be added to the part number. The
Suffix “F” is required only for 4 Form C
contact type. The 2 Form C and 3 Form C
contact type is originally cadmium-free,
the suffix “F” is not required.)
Please replace parts containing
Cadmium with Cadmium-free products
and evaluate them with your actual
application before use because the life of
a relay depends on the contact material
and load.
ORDERING INFORMATION
HP
Contact arrangement
2: 2 Form C
3: 3 Form C
4: 4 Form C
Terminal arrangement
Nil: Standard plug-in terminal
TM: TM type (2 Form C only)
M: Direct mounting (3 Form C only)
Operation indication
Nil: Without indication
L: With indication
Coil voltage
AC 24, 48, 100, (115), 200, (220), (240) V
DC 12, 24, 48, 100, (110) V
Contact material
F: 4 Form C, Silver alloy (cadmium-free)
Nil: 2 Form C, 3 Form C (Silver)
With LED indicator type
Coil voltage: 12, 24 V AC 12, 24, 48 V DC
With neon lamp type
Coil voltage: 100, 115, 200, 220, 240 V AC 100, 110 V DC
ds_61C07_en_hp: 011111D
1
HP
Discontinued as of August 31, 2012
TYPES
1. Plug-in type
2 Form C
Part No.
HP2-AC24V
HP2-AC48V
HP2-AC100V
HP2-AC115V
HP2-AC200V
HP2-AC220V
HP2-AC240V
HP2-DC12V
HP2-DC24V
HP2-DC48V
HP2-DC100V
HP2-DC110V
Coil voltage
24V AC
48V AC
100V AC
115V AC
200V AC
220V AC
240V AC
12V DC
24V DC
48V DC
100V DC
110V DC
3 Form C
Part No.
HP3-AC24V
HP3-AC48V
HP3-AC100V
HP3-AC115V
HP3-AC200V
HP3-AC220V
HP3-AC240V
HP3-DC12V
HP3-DC24V
HP3-DC48V
HP3-DC100V
HP3-DC110V
4 Form C
Part No.
HP4-AC24V-F
HP4-AC48V-F
HP4-AC100V-F
HP4-AC115V-F
HP4-AC200V-F
HP4-AC220V-F
HP4-AC240V-F
HP4-DC12V-F
HP4-DC24V-F
HP4-DC48V-F
HP4-DC100V-F
HP4-DC110V-F
3 Form C
Part No.
HP3-L-AC24V
HP3-L-AC100V
HP3-L-AC115V
HP3-L-AC200V
HP3-L-AC220V
HP3-L-AC240V
HP3-L-DC12V
HP3-L-DC24V
HP3-L-DC48V
HP3-L-DC100V
HP3-L-DC110V
4 Form C
Part No.
HP4-L-AC24V-F
HP4-L-AC100V-F
HP4-L-AC115V-F
HP4-L-AC200V-F
HP4-L-AC220V-F
HP4-L-AC240V-F
HP4-L-DC12V-F
HP4-L-DC24V-F
HP4-L-DC48V-F
HP4-L-DC100V-F
HP4-L-DC110V-F
Standard packing (2 Form C): Carton: 20 pcs.; Case: 100 pcs.
Standard packing (3 Form C, 4 Form C): Carton: 10 pcs.; Case: 50 pcs.
2. Plug-in type (with LED indication)
Coil voltage
With LED indication
With neon lamp
With LED indication
With neon lamp
24V AC
100V AC
115V AC
200V AC
220V AC
240V AC
12V DC
24V DC
48V DC
100V DC
110V DC
2 Form C
Part No.
HP2-L-AC24V
HP2-L-AC100V
HP2-L-AC115V
HP2-L-AC200V
HP2-L-AC220V
HP2-L-AC240V
HP2-L-DC12V
HP2-L-DC24V
HP2-L-DC48V
HP2-L-DC100V
HP2-L-DC110V
Standard packing (2 Form C): Carton: 20 pcs.; Case: 100 pcs.
Standard packing (3 Form C, 4 Form C): Carton: 10 pcs.; Case: 50 pcs.
3. TM type and Direct mount type
2 Form C (TM type)
Part No.
HP2-TM-AC24V
HP2-TM-AC48V
HP2-TM-AC100V
HP2-TM-AC115V
HP2-TM-AC200V
HP2-TM-AC220V
HP2-TM-AC240V
HP2-TM-DC12V
HP2-TM-DC24V
HP2-TM-DC48V
HP2-TM-DC100V
HP2-TM-DC110V
Coil voltage
24V AC
48V AC
100V AC
115V AC
200V AC
220V AC
240V AC
12V DC
24V DC
48V DC
100V DC
110V DC
3 Form C (direct mount type)
Part No.
HP3-M-AC24V
HP3-M-AC48V
HP3-M-AC100V
HP3-M-AC115V
HP3-M-AC200V
HP3-M-AC220V
HP3-M-AC240V
HP3-M-DC12V
HP3-M-DC24V
HP3-M-DC48V
HP3-M-DC100V
HP3-M-DC110V
Standard packing: Carton: 10 pcs.; Case: 50 pcs.
4. Direct mount type (with LED indication)
Coil voltage
With neon lamp
100V AC
115V AC
200V AC
220V AC
240V AC
100V DC
110V DC
3 Form C
Part No.
HP3-ML-AC100V
HP3-ML-AC115V
HP3-ML-AC200V
HP3-ML-AC220V
HP3-ML-AC240V
HP3-ML-DC100V
HP3-ML-DC110V
Standard packing: Carton: 10 pcs.; Case: 50 pcs.
Notes: 1. Standard packaging is handled in units of inner cartons. Please specify if you require inner cartons to be boxed.
2. Sockets, terminal sockets and installation brackets are not included. Please order these separately.
3. For products compliant with international standards, please refer to the standards chart.
2
ds_61C07_en_hp: 011111D
HP
Discontinued as of August 31, 2012
RATING
1. Coil data
1) AC coils
Contact
arrangement
2 Form C
3 Form C
4 Form C
Nominal coil current
(mA)
50Hz
60Hz
94mA
78mA
46.5mA
39mA
25.3mA
21mA
23.1mA
18mA
12.4mA
11mA
10.6mA
9.5mA
10.0mA
9.0mA
148.7mA
130mA
74.2mA
65mA
36.4mA
32mA
32.5mA
28.5mA
18.2mA
16mA
16.0mA
14.2mA
15.8mA
13.9mA
456mA
400mA
229mA
200mA
108mA
95mA
57.3mA
50mA
47.6mA
42mA
28.5mA
25mA
23.8mA
21mA
23.3mA
20.5mA
Nominal operating
power (VA)
50Hz
60Hz
2.25VA
1.9VA
2.23VA
1.9VA
2.36VA
2.1VA
2.31VA
2.1VA
2.48VA
2.2VA
2.34VA
2.1VA
2.40VA
2.2VA
3.56VA
3.1VA
3.56VA
3.1VA
3.64VA
3.2VA
3.74VA
3.3VA
3.65VA
3.2VA
3.54VA
3.1VA
3.79VA
3.3VA
5.47VA
4.8VA
5.49VA
4.8VA
5.18VA
4.6VA
5.73VA
5.0VA
5.47VA
4.8VA
5.69VA
5.0VA
5.24VA
4.6VA
5.58VA
4.9VA
Inductance
(H)
50Hz
60Hz
0.753
0.776
3.055
3.106
12.60
12.03
16.70
15.83
48.03
45.81
61.28
57.90
69.00
66.26
0.0494
0.475
1.976
1.899
8.500
8.038
10.79
10.36
33.53
32.10
41.35
39.32
45.94
44.05
0.080
0.077
0.320
0.309
1.348
1.292
5.348
5.156
7.264
6.953
21.27
20.45
27.75
26.57
30.98
29.75
Nominal coil
voltage
Nominal coil current
(mA)
Nominal operating
power (W)
Coil resistance
()
12V DC
24V DC
48V DC
100V DC
110V DC
12V DC
24V DC
48V DC
100V DC
110V DC
12V DC
24V DC
48V DC
100V DC
110V DC
109mA
54.5mA
26.7mA
14.9mA
15.0mA
120mA
60mA
31mA
15.6mA
14.9mA
127mA
63mA
32.0mA
16.3mA
15.7mA
1.3W
1.3W
1.3W
1.5W
1.7W
1.4W
1.4W
1.5W
1.6W
1.6W
1.5W
1.5W
1.5W
1.6W
1.7W
110
440
1,800
6,700
7,300
100
400
1,560
6,400
7,450
95
380
1,500
5,950
7,000
Nominal coil
voltage
24V AC
48V AC
100V AC
115V AC
200V AC
220V AC
240V AC
24V AC
48V AC
100V AC
115V AC
200V AC
220V AC
240V AC
12V AC
24V AC
48V AC
100V AC
115V AC
200V AC
220V AC
240V AC
Pick-up voltage
(at 20C 68F)
Drop-out voltage
(at 20C 68F)
Max. allowable
voltage
(at 20C 68F)
80%V or less of
nominal voltage
(Initial)
30%V or more of
nominal voltage
(Initial)
110%V of
nominal voltage
80%V or less of
nominal voltage
(Initial)
30%V or more of
nominal voltage
(Initial)
110%V of
nominal voltage
80%V or less of
nominal voltage
(Initial)
30%V or more of
nominal voltage
(Initial)
110%V of
nominal voltage
Pick-up voltage
(at 20C 68F)
Drop-out voltage
(at 20C 68F)
Max. allowable
voltage
(at 20C 68F)
80%V or less of
nominal voltage
(Initial)
15%V or more of
nominal voltage
(Initial)
110%V of
nominal voltage
80%V or less of
nominal voltage
(Initial)
15%V or more of
nominal voltage
(Initial)
110%V of
nominal voltage
80%V or less of
nominal voltage
(Initial)
15%V or more of
nominal voltage
(Initial)
110%V of
nominal voltage
2) DC coils (20C 68F)
Contact
arrangement
2 Form C
3 Form C
4 Form C
Notes: 1. The rated current area is 15% (60Hz) [AC coils],. 10% (20C) [DC coils]
2. The coil resistance for DC operation is the value measured when the coil temperature is 20C 68F. Compensate 0.4% for every 1C change in temperature.
3. The relay operates in a range of 80% to 110% V of the voltage rating, but ideally, in consideration of temporary voltage fluctuations, it should be operated at the
rated voltage. In particular, for AC operation, if the impressed voltage drops to 80% V or more below the rated voltage, humming will occur and a large current will
flow leading possibly to coil burnout.
4. For use with 200 V DC, connect a 6.7k (10W) resistor, in series, to the 100 V DC relay [3 Form C type is .6.4k (5W); 4 Form C type is .6.2k (10W)].
5. As a general rule, only a pure DC voltage should be used for the coil drive.
However, a DC power supply that contains ripples has characteristics that differ from pure DC.
Therefore, please verify characteristics (operate voltage, release voltage, humming) using the actual circuit that will be used.
ds_61C07_en_hp: 011111D
3
HP
Discontinued as of August 31, 2012
2. Specifications
Characteristics
Contact
Rating
Item
Arrangement
Initial contact resistance, max
2 Form C, 3 Form C
Contact material
4 Form C
Nominal switching capacity
Min. switching capacity (Reference value)*1
Insulation resistance (Initial)
Between open contacts
Electrical
characteristics
Breakdown voltage
(Initial)
Between contact sets
Between contact and coil
Temperature rise
Operate time*2
Release time*2
Mechanical
characteristics
Expected life
Conditions
Functional
Destructive
Functional
Vibration resistance
Destructive
Mechanical
Shock resistance
Conditions for operation, transport and storage*3
Max. Operating speed
Unit weight
Specifications
2 Form C, 3 Form C, 4 Form C
Max. 15 m (By voltage drop 6 V DC 1A)
Ag
Ag alloy (cd free)
10A 250V AC (resistive load)
100mA 5V DC
Min. 100M (at 500V DC)
Measurement at same location as “Initial breakdown voltage” section.
1,000 Vrms for 1min (2 Form C, 4 Form C).
2,000 Vrms for 1min (3 Form C) (Detection current: 10mA.)
1,500 Vrms for 1min (2 Form C, 4 Form C).
2,000 Vrms for 1min (3 Form C) (Detection current: 10mA.)
1,500 Vrms for 1min (2 Form C, 4 Form C).
2,000 Vrms for 1min (3 Form C) (Detection current: 10mA.)
Max. 65C (By temperature method, at 40C, nominal current)
Max. 25ms (2 Form C), Max.30ms (3 Form C, 4 Form C)
(Nominal voltage applied to the coil, excluding contact bounce time.)
Max. 25ms (2 Form C), Max.30ms (3 Form C, 4 Form C)
(Nominal voltage applied to the coil, excluding contact bounce time.) (without diode)
Min. 98 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10s.)
Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 1 mm (Detection time: 10s.)
10 to 55 Hz at double amplitude of 2 mm
Min. 107
Ambient temperature: –50C to +40C –58F to +104F
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
20 cpm (at max. rating)
2 Form C: approx. 60g 2.12oz, 3 Form C: approx. 100g 3.53oz, 4 Form C: approx. 125g 4.41oz
*1This value can change due to the switching frequency, environmental conditions and desired reliability level, therefore it is recommended to check this with the actual load.
*2For the AC coil types, the operate/release time will differ depending on the phase.
*3The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to “6. Usage, Storage and Transport
Conditions“ in AMBIENT ENVIRONMENT section in Relay Technical Information.
3. Electrical life
1) AC load
Voltage
Load
Current
125V AC
Resistive (A) (cos=1)
Inductive (A) (cos=0.4)
—
—
10
7.5
5
3
1
0.7
250V AC
Resistive (A) (cos=1)
Inductive (A) (cos=0.4)
10
7.5
7.5
5
3
2
0.6
0.4
Expected life
Min. 2105
Min. 5105
Min. 106
Min. 2106
Note: When the electromagnet or exciting coil (Solenoid, etc.) is the load, the value of motor or lamp load is applicable.
2) DC load
Voltage
Load
Current
24V DC
Resistive (A)
—
7.5
5
1
125V DC
Inductive (A)
7
5
3
0.6
Resistive (A)
—
0.5
0.3
0.1
Inductive (A)
—
0.4
0.2
0.06
Expected life
Min. 2105
Min. 5105
Min. 106
Min. 2106
Notes:
1.
For DC inductive loads, use an arc suppressing circuit.
2.
Cautions at DC load use: when used under a DC load operating at high repetition rate with considerable arcing, corrosion of the contacts and/or the contact blades is
likely to occur.
4
ds_61C07_en_hp: 011111D
HP
Discontinued as of August 31, 2012
4. Life of LED and neon lamp (with operation indication)
Continuous
25,000 hours (approx. 3 years)
50,000 hours (approx. 5.5 years)
With neon lamp
With LED indication
With neon lamp
Use rating (ON time) 50%
Approx. 6 years
100,000 hours (approx. 11 years)
Schematic
Neon lamp
(Coil terminal No.)
Schematic
With LED indication
LED
LED
Coil terminal No. and polarity (DC type)
Protection diode
(Coil terminal No.)
Terminal
No.
Polarity
(+)
(–)
HP2
7
2
HP3
10
2
HP4
10
1
REFERENCE DATA
1. Life curve
AC resistive load
Mechanical life
more than 10,000,000
operations
900
Contact current, A
Operations, ×10
4
1,000
2. Max. switching capacity
800
700
600
500
400
10
AC inductive load
(cosϕ=0.4)
1 DC inductive
load
(L/R=7ms)
DC resistive
load
300
200
0
25
100
0
125 V A
VA
Cc
C cosϕ
osϕ = 1
5
=1
0.1
10
10
Load current, A
ds_61C07_en_hp: 011111D
100
500 1,000
Contact voltage, V
5
HP
Discontinued as of August 31, 2012
DIMENSIONS(mm inch)
CAD Data
Data from our Web site.
Download CAD
Plug-in type (2 Form C)
External dimensions
Schematic (Bottom view)
CAD Data
8
1
7
2
5 8
5
.197.315 .197
0.5
.020
6
3
5
4
44
1.732
51
2.008
7
.276
0.8
.031
25
.984
15
.591
Compatible with tab terminal
#205 series receptacle.
0.8
.031
8
1
7
6
2
3
5
4
5.26
.207
5.26
.207
0.8
.031
0.8
.031
9.5
.374
7.5 36
.2951.417
5.8
.228
Dimension:
Max. 2mm .079 inch:
2 to 9mm .079 to .354 inch:
9 to 20mm .354 to .787 inch:
Min. 20mm .787 inch:
5.3
.209
5.26 5.26
.207 .207
10
.394
Plug-in type (3 Form C)
External dimensions
CAD Data
Tolerance
0.2 .008
0.5 .020
1 .039
1.5 .059
Schematic (Bottom view)
5
8
5
.197 .315 .197
38
1.496
2
10
0.5
.020
44
1.732
11
3
1
9
6
4
8
7
5
5
.197
7
.276
36
1.417
3
.118
Compatible with tab terminal
#187 series receptacle.
38
1.496
11 11
.433 .433
4.75 4.75 4.75
.187 .187 .187
2.5 2.5
.098 .098
6
0.5
.020
5.75
.226
5.5
.217
0.5
.020
8.5
0.5 .020
.335 36
7.65 1.417
2 .079
.301
0.5 .020
4.1
2 .079
.161
Dimension:
Max. 2mm .079 inch:
2 to 9mm .079 to .354 inch:
9 to 20mm .354 to .787 inch:
Min. 20mm .787 inch:
Tolerance
0.2 .008
0.5 .020
1 .039
1.5 .059
ds_61C07_en_hp: 011111D
HP
Discontinued as of August 31, 2012
Plug-in type (4 Form C)
External dimensions
Schematic (Bottom view)
CAD Data
9
0.5
.020
15
11
2
10
44
1.732
51
2.008
1
8
14
7
6
12
3
5
4
7
.276
50
1.969
40
1.575
10
.394
0.8 0.8
.031 .031
0.8
.031
Compatible with tab terminal
#205 series receptacle.
0.8
.031
5.26
.207
5.26
.207
0.8
.031
0.8
.031
2
9
11
15
10
1
8
14
12
3
7
9
5
4
5.26 5.26
.207 .207
10
.394
Dimension:
Max. 2mm .079 inch:
2 to 9mm .079 to .354 inch:
9 to 20mm .354 to .787 inch:
Min. 20mm .787 inch:
5.3
.209
5.26 5.26
.207 .207
25
.984
10
.394
TM type
(2 Form C)
9.5
.374
36
7.5 1.417
.295
5.8
.228
External dimensions
Tolerance
0.2 .008
0.5 .020
1 .039
1.5 .059
Mounting hole diagram
2.8
.110
CAD Data
Relay space
(Area shown by the
broken line)
45.5
1.791
46.8
1.843
7
.276
2-M4 screw hole
or 2-4.5 dia. hole
2-M.157 screw hole
or 2-.177 dia. hole
5.5
.217
24.7
.972
2
.079
30
1.181
Tolerance: 0.1 .004
35.7
1.406
0.8
.031
Dimension:
Max. 2mm .079 inch:
2 to 9mm .079 to .354 inch:
9 to 20mm .354 to .787 inch:
Min. 20mm .787 inch:
Tolerance
0.2 .008
0.5 .020
1 .039
1.5 .059
15
.591
0.8
.031
5.26
.207
5.26
.207
0.8
.031
0.8
.031
2.25R .089R
5.26
.207
4.5
.177
10
.394
(Pitch for side-by-side mounting)
Compatible with tab terminal
#205 series receptacle.
9.5
.374
45.5
7.5 1.791 58
2.283
.295
5.8
.228
Installed relay
35.7
1.406
5.3
.209
5.26
.207
52.3
2.059
2-M4 screw
2-M.157
Schematic (Bottom view)
ds_61C07_en_hp: 011111D
8
7
1
2
6
5
3
4
Spring washer
Nut
Panel (chassis)
7
HP
Discontinued as of August 31, 2012
Direct mounting type
(3 Form C)
External dimensions
38
1.496
16
.630
4.2
.165
CAD Data
Relay space
(Area shown by the
broken line)
2.1R
.083R
44
1.732 60
2.362 73.5
7
2.894
.276 11
.433
3
.118
5
.197
Dimension:
Max. 2mm .079 inch:
2 to 9mm .079 to .354 inch:
9 to 20mm .354 to .787 inch:
Min. 20mm .787 inch:
Tolerance
0.2 .008
0.5 .020
1 .039
1.5 .059
60
2.362
2-M4 screw hole
(or 2-4.2 dia. hole)
2-M.157 screw hole
(or 2-.165 dia. hole)
2
.079
40
1.575
20.5
.807
2.1R
.083R
2.5
.098
Mounting hole diagram
Tolerance: 0.1 .004
4.2
36
.165
1.417
16
.630
38
Compatible with tab terminal
1.496
#187 series receptacle.
11 11
.433 .433
4.75 4.75 4.75
.187 .187 .187 2.5
5.75
.098 .226
0.5 .020
5.5
0.5
.217
.020 8.5
0.5 .020 .335 36
7.65 1.417
2 .079 .301
0.5 4.1
.020 .161
2
.079
(Pitch for side-by-side mounting)
Installed relay
2-M4 screw
2-M.157
Panel
(chassis)
Nut
Schematic (Bottom view)
5
.197
60
2.362
44
73.5
1.732
2.894
11
.433
2
10
11
3
1
9
6
4
8
7
5
Spring washer
20.5
.807
16
.630
38
1.496
7
.276
36
1.417
For Cautions for Use, see Relay Technical Information.
8
ds_61C07_en_hp: 011111D
HP
VDE
Discontinued
Discontinued as
as of
of August
August 31,
31, 2012
2012
Partial approval
ACCESSORIES
(Sockets and
Terminal sockets)
Socket for rectangular hold boring
HP RELAY
ACCESSORIES
Terminal socket for DIN rail assembly
Products to be discontinued.
TYPES
1. For DIN rail terminal sockets, hold-down clip included.
2. For square hole sockets, powerful hold-down clip included.
Type
Square hole socket
DIN rail terminal socket
Common part
No. of poles
Item
Part No.
2-pole
3-pole
4-pole
2-pole
3-pole
4-pole
2/3/4-pole (common)
HP2-square hole socket
HP3-square hole socket
HP4-square hole socket
HP2-DIN terminal socket
HP3-DIN terminal socket
HP4-DIN terminal socket
HP-hold down clip for socket
HP2-SRS
HP3-SRS
HP4-SRS
HP2-SFD
HP3-SFD
HP4-SFD
AW5806
Packing quantity
Carton
20 pcs.
10 pcs.
10 pcs.
10 pcs.
10 pcs.
5 pcs.
—
Case
100 pcs.
50 pcs.
50 pcs.
50 pcs.
50 pcs.
25 pcs.
50 pcs.
Note: Socket and terminal socket conform to UL, CSA as standard.
ds_61C07_en_hp: 011111D
9
HP
Discontinued as of August 31, 2012
DIMENSIONS (Unit: mm inch)
1. Socket for rectangular hold boring (hold-down clip included)
HP2-Socket (HP2-SRS)
Front surface mounting
Mounting dimensions
2-4.2 dia. hole (or 2-M4 screw hole)
2-.165 dia. hole (or 2-M.157 screw hole)
Hold-down clip
HP relay
52±3
2.047±.118
48±0.5
1.890±.020
34
1.339
Socket
M4 screw
M.157
Spring washer
14
.551
24
.945
When the socket is mounted from
the top of the panel (chassis).
Panel (chassis)
Tolerance: 0.1 .004
External dimensions
Hold-down clip
HP relay
Rear surface mounting
53±3
2.087±.118
5
.197
48±0.2
1.890±.008 38
56 1.496
2.205
22
.866
39
1.535
33
1.299
6.2
.244
1.0
.039
6
.236
13
.512
5.5
.217
30
1.181
13
.512
4.2
.165
31
1.220
When the socket is mounted from
below the panel (chassis).
5
.197
4.1
.161
Socket
M4 screw
M.157
Spring washer
52
2.047
Tolerance: 0.1 .004
Panel (chassis)
Notes: 1. Optimum space-saving panel cut-out.
2. Can be mounted from either the front or
the rear of the panel.
3. Hold-down clip is included in package.
General tolerance: 0.1 .004
HP3-Socket (HP3-SRS)
Front surface mounting
Mounting dimensions
2-4.2±0.1 dia. hole (or M4 screw hole)
2-.165±.004 dia. hole (or M.157 screw hole)
31+1
−0
1.220+.039
−0
Hold-down clip
HP relay
52±3
2.047±.118
48±0.5
1.890±.020
Socket
M4 screw
M.157
Spring washer
15.5
.610
31+1
−0
1.220+.039
−0
Panel (chassis)
Tolerance: 0.1 .004
External dimensions
Rear surface mounting
Hold-down clip
HP relay
48±0.2
5
1.890±.079
.197
56
22
38
.866 2.205 1.496
5
.197
3.5
.138
4.1
.161
45
1.772
3.5
.138
6.2
.244
1.0
.039
14.5
5.5 .571
.217
30
1.181
8
.315
General tolerance: 0.1 .004
10
53±3
2.087±.118
52
2.047
Socket
M4 screw
M.157
Spring washer
(48)
(1.890)
39 +1
−0
1.535 +.039
−0
4.2
.165
46+1
−0
1.811+.039
−0
Tolerance: 0.1 .004
14.5
.571
Panel (chassis)
Notes: 1. Optimum space-saving panel cut-out.
2. Can be mounted from either the front or
the rear of the panel.
3. Hold-down clip is included in package.
ds_61C07_en_hp: 011111D
HP
Discontinued as of August 31, 2012
HP4-Socket (HP4-SRS)
Front surface mounting
Mounting dimensions
2-M4 screw hole (or 4.2±0.1 dia. hole)
2-M.157 screw hole (or .165±.004 dia. hole)
Hold-down clip
HP relay
52±3
2.047±.118
34 +1
−0
1.339 +.039
−0
48 +1
−0
+.039
1.890 −0
Socket
M4 screw
M.157
Spring washer
14
.551
48±0.5
1.890±.020
Panel (chassis)
Tolerance: 0.1 .004
External dimensions
Rear surface mounting
Hold-down clip
HP relay
2-4.2 dia. hole
2-.165 dia.
5
.197
48±0.2
1.890±.008
38
56 1.496
2.205
22
.866
33
1.299
4.1
.161
1.0
.039
58
2.283
13
5.5 .512
.217
Socket
M4 screw
M.157
Spring washer
39 +1
−0
1.535 +.039
−0
48±0.2
1.890±.008
3
.118
5
.197
6.2
.244
53±3
2.087±.118
3
.118
6
.236
A
3
.118
13
.512
3
25
.118
.984
+1
58 −0
2.283 +.039
−0
General tolerance: 0.1 .004
Tolerance: 0.1 .004
Panel (chassis)
Notes: 1. Optimum space-saving panel cut-out.
2. Can be mounted from either the front or
the rear of the panel.
3. Hold-down clip is included in package.
* When using the former hold-down clip, it is necessary
to cut out the A section marked by the broken line
(not necessary with the powerful hold-down clip).
2. Terminal socket for DIN rail assembly (hold-down clip and installation screw included)
HP2-Terminal socket for DIN rail assembly (HP2-SFD)
External dimensions
23.8±0.6
.937±.024
10±0.6
.394±.024
* Installation screw block
(installation screw, hexagonal nut,
spring washer)
Hold-down clip
Schematic
M3.5 screw
M.138
22±0.6
.866±.024
15±0.2
.591±.008
4.1±0.3
4.1±.012
6±0.3
6±.012
2
80±1
3.150±.039
4
HP2 relay
3
6
69±0.5
2.717±.020
5
4
30
1.181 .157
5.8±0.2
.228±.008
33.8±0.6
1.331±.024
37.9±0.6
1.492±.024
8
80
3.150
69±1
2.717±.039
0.6±0.15
.024±.006
9.5±0.2
58±1
2.283±.039 .374±.008
7.5±0.2
36±1
.295±.008
1.417±.039
7
1
Mounting hole diagram
22±0.2 12±0.2 22±0.2
.866±.008 .472±.008 .866±.008
8±0.2
.315±.008
30±0.6
1.181±.024
2-M4 screw hole
(or 4.2±0.1 dia. hole)
2-M.157 screw hole
(or .165±.004 dia. hole)
Panel hole dimensions
for side-by-side installation
30
1.181
Notes: 1. For direct mounting, use the included installation screw block.
2. A hold-down clip is included with the terminal socket.
ds_61C07_en_hp: 011111D
11
HP
Discontinued as of August 31, 2012
HP3-Terminal socket for DIN rail assembly (HP3-SFD)
External dimensions
23.8±0.6
.937±.024
10±0.6
.394±.024
Schematic
2
* Installation screw block
(installation screw, hexagonal nut,
spring washer)
4.1±0.3
.161±.012
6±0.3
.236±.012
Hold-down clip
1
M3.5 screw
M.138
37±0.6
1.457±.024
69±1
1.75±0.15
2.717±.039 .069±.006
7.65±0.2
58±1
2.283±.039 .301±.008
8.5±0.2
36±1
.335±.008
1.417±.039
80±1
3.150±.039
10
3
4
5
37±0.2 12±0.2
37±0.2
1.457±.008 12±.008 1.457±.008
11
6
80
3.150
69±0.5
2.717±.020
9
7
8
4
45
1.772 .157
5.5±0.2
.217±.008
33.8±0.6
1.331±.024
37.9±0.6
1.492±.024
Mounting hole diagram
8±0.2
.315±.008
45±0.6
1.772±.024
HP3 relay
2-M4 screw hole
(or 4.2±0.1 dia. hole)
2-M.157 screw hole
(or .165±.004 dia. hole)
Panel hole dimensions
for side-by-side installation
45
1.772
Notes: 1. For direct mounting, use the included installation screw block.
2. A hold-down clip is included with the terminal socket.
HP4-Terminal socket for DIN rail assembly (HP4-SFD)
External dimensions
23.8±0.6
.937±.024
10±0.6
.394±.024
Schematic
* Installation screw block
(installation screw, hexagonal nut,
spring washer)
Hold-down clip
4.1±0.3
.161±.012
6±0.3
.236±.012
2
17
10
15
9
12 14
8
Mounting hole diagram
12±0.2
53±0.2
53±0.2 .472±.008
2.087±.008
2.087±.008
80
3.150
4
9.5±0.2
58±1
2.283±.039 .374±.008
7.5±0.2
36±1
1.417±.039 .295±.008
16
11
3
69±1
0.6±0.15
2.717±.039 .024±.006
80±1
3.150±.039
1
M3.5 screw
M.138
53±0.6
2.087±.024
15±0.2 15±0.2
.591±.008 .591±.008
8±0.2
.315±.008
5
6
69±0.5
2.717±.020
7
61
2.402
4
.157
61
2.402
5.8±0.2
.228±.008
33.8±0.6
1.331±.024
37.9±0.6
1.492±.024
HP4 relay
10±0.2
.394±.008
10±0.2
25±0.1
.394±.008
.984±.004
61±0.6
2.402±.024
Panel hole dimensions
for side-by-side installation
2-M4 screw hole
(or 4.2±0.1 dia. hole)
2-M.157 screw hole
(or .165±.004 dia. hole)
Notes: 1. For direct mounting, use the included installation screw block.
2. A hold-down clip is included with the terminal socket.
12
ds_61C07_en_hp: 011111D
HP
Discontinued as of August 31, 2012
NOTES
1. There are two types of HP relay: plugin and direct mounting (HP2-TM and
HP3-M only).
Avoid use of direct mounting types in
sockets or terminal sockets.
Note: Mounting measurements for direct mounting
types (HP2-TM and HP3-M) are shown in the
drawing on page 7.
2. The terminals are compatible with tab
terminals. Consequently, for direct
mounting types, in addition to soldering,
AMP terminals can be used.
Part number
HP2
HP3
HP4
Compatible tab terminal
#205 series
#187 series
#205 series
3. When tightening the fixing screws of
direct mounting types, use washers to
prevent damage or distortion.
The optimum torque range is 0.49 to 0.69
N·m, (5 to 7 kgf·cm).
To prevent loosening of direct mounting
types, terminal sockets and sockets, etc.,
when fixing the screws, use spring
washers, etc. Moreover, wiring
(soldering), should be done with care
while ensuring strong connections.
4. When tightening terminal socket fixing
screws, to prevent damage, the optimum
torque range should be 0.784 to 0.98
N·m, (8 to 10 kgf·cm).
5. Avoid use in adverse conditions, such
as where the relay will be subjected to
strong vibrations or shock, where there is
exposure to harmful gas, or where
ambient temperatures are high (more
than 40C).
6. Use in DC load
Abnormal wear of the contacts and
contact springs will occur when the
switching frequency is high and there are
large arcs. In particular, if high-frequency
operation in hot or humid conditions is
intended, use arc-suppressing circuits.
7. There is no particular specification for
HP relay mounting orientation.
8. Do not insert or remove relays into or
out of live circuits.
For Cautions for Use, see Relay Technical Information.
ds_61C07_en_hp: 011111D
13
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF