AOX2-Box-v06

AOX2-Box-v06
10/8/2006
4:40 PM
Page 1
Model AOX2
Professional-grade instruments for field service
AOX2-Box v06.qxd
Combustion Check
Accessory Head with Hi-Temp
Thermocouple and Pump
AOX2 Specifications
Function
Range
Accuracy /
Resolution
%CO2
0 to 25%
±0.3% / 0.1%
%O2
Temperature
0 to 25%
±0.3% / 0.1%
-58°F to 1000°F
±0.6%+3°F* / 0.1°
* System accuracy
(Accessory head + k-type thermocouple + meter after system field calibration)
AOX2 Combustion Head
Measure Products of Combustion
Measures %O2 (oxygen) and
flue gas temperature then calculates
%CO2 (carbon dioxide).
Gas and Oil Fuel Types
Just flip the switch to change between
gas and oil fuel combustion.
Temperature Advantages
Select between °F and °C
temperature scales. Calibrate
thermocouple by adjusting pot.
Connects to Fieldpiece Meters
Just snap the accessory head onto
meter or use deluxe silicone leads
for remote connection.
Auto Off
Auto off can be disabled for data
logging. Use with the DL2 Data Logger
to log %O2, %CO2, or flue gas temperature.
AOX2
Combustion Check
Accessory Head
with Thermocouple
and Pump
Combustion analysis?
With fuel prices being at an all time
high, it is important that combustion
be as efficient as possible. The
AOX2 accessory head allows you to
check the flue temperature as well as
the %O2 and calculated %CO2 of
combustion products. Many gas and
oil fired boilers and furnaces have
recommended flue temperatures and
levels for the %O2 and %CO2 that
should be present in the flue (as well
as CO ppm and NOx ppm).
The AOX2 is designed to allow you
to check if the equipment is within the
design criteria quickly and
inexpensively. The AOX2 also gives
you the basic measurements for more
sophisticated combustion analysis if
so desired.
AOX2
Combustion Check
Model: AOX2
Professional-grade
instruments for field service
72641 00179
Model AOX2
Combustion Check
Accessory Head with
Hi-Temp Thermocouple and Pump
Flue Gas
Measurement
O2 CO2 Temp
Pump
and Filters
Use the hand
pump to draw in
the flue gas.
Water trap with
filter keeps the
sensor clean and
free of moisture.
Includes extra
filters.
Other Fieldpiece
accessory heads
High temperature
K-type thermocouple
ATBF1
8
Fieldpiece accessory heads all
work in the same basic way so
it’s easy to expand
your toolkit when
you’re ready to.
Hi-Temp
Thermocouple
Combustion Head
AOX2
Pump with water trap
AOXP2
Clip the k-type
thermocouple onto
the pump’s snoot
to measure flue
gas temperature.
Extra O-ring, filters, and C-clips
RAOX9
Professional-grade
instruments for field service
Fieldpiece Instruments
Phone: (714) 257- 9060 Fax: (714) 257- 9069
www.fieldpiece.com
Fieldpiece accessory heads
measure contact temperature (dual),
IR temperature, RH%, wet bulb,
dew point, dry bulb, air velocity, CO,
milliohms, true RMS, high voltage,
vacuum (vacuum gauge), gas and
static pressure (manometer),
pressure, superheat, and
subcooling.
EHDL1 Electronic
Handle not included
H26-641