advertisement
INSTALLER / CONSUMER
SAFETY INFORMATION
PLEASE READ THIS MANUAL BE-
FORE INSTALLING AND USING
APPLIANCE.
WARNING!
IF THE INFORMATION IN THIS
MANUAL IS NOT FOLLOWED EX-
ACTLY, A FIRE OR EXPLOSION MAY
RESULT CAUSING PROPERTY
DAMAGE, PERSONAL INJURY OR
LOSS OF LIFE.
Radiance
Natural Vent Gas
Heater
Model RNVOD: 3340 thru 3349,
3355, 3356
—
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
—
WHAT TO DO IF YOU SMELL
GAS:
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in your building.
• Immediately call your gas supplier from your neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas supplier.
This appliance may be installed in an after market permanently located manufactured
(mobile) home where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate.
This appliance is not convertible for use with other gases unless a certified kit is used.
Homeowner’s Installation and Operating Manual
DESIGN
CER
TIFIE D
C E RT I F I E D
4409
CFM Specialty Home Products
410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777 www.majesticproducts.com • www.vermontcastings.com
INSTALLER: DO NOT DISCARD THIS MANUAL -LEAVE FOR HOMEOWNER
20004409 12/04 Rev. 10
Radiance Natural Vent Gas Heater
Table of Contents
PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE.
Thank you and congratulations on your purchase of a Vermont Castings stove.
IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty.
Installation & Operating Instructions
Stove Dimensions .............................................................................................................. 4
Clearance Requirements ................................................................................................... 5
Alcove Minimum Dimensions ............................................................................................. 5
Hearth Requirements ......................................................................................................... 5
Gas Specifications ............................................................................................................. 6
Gas Inlet and Manifold Pressures ...................................................................................... 6
High Elevations .................................................................................................................. 6
Venting Requirements and Options ................................................................................... 6
Vent Layout and Height Requirements .............................................................................. 6
Passing Through a Combustible Wall or Ceiling ................................................................ 7
Venting Requirements ........................................................................................................ 7
Assembly Procedures
Tools Required ................................................................................................................... 8
Parts Bag Contents ............................................................................................................ 8
Unpack and Assemble Legs .............................................................................................. 8
Install the Optional Fan (Serial #’s up to #1456 (RNVODRN), up to #1943(RNVODRP) .. 8
Install the Optional Fan (Starting with Serial #1457 (RNVODRN), #1944 (RNVODRP) .. 10
Venting System Assembly ............................................................................................... 12
Connect the Gas Supply Line .......................................................................................... 13
Burner Information ........................................................................................................... 13
Install ON/OFF Switch ...................................................................................................... 13
Thermostat Connection .................................................................................................... 14
Install the Mesh and Grille ................................................................................................ 14
Install Rear Bracket and Log Set ..................................................................................... 14
Operation
Operable Doors ................................................................................................................ 16
Your First Fire .................................................................................................................. 16
Pilot and Burner Inspection .............................................................................................. 16
Flame & Temperature Adjustment ................................................................................... 16
Flame Characteristics ...................................................................................................... 16
Lighting and Operating Instructions ................................................................................. 17
Troubleshooting ............................................................................................................... 18
Fuel Conversion Instructions ............................................................................................ 19
Maintenance
Annual System Inspection ................................................................................................ 21
Logset and Burner Cleaning and Inspection .................................................................... 21
Care of Cast Iron .............................................................................................................. 21
Cleaning the Glass ........................................................................................................... 21
Glass Replacement .......................................................................................................... 21
Gasket Replacement ........................................................................................................ 22
Inspect the Vent System Annually ................................................................................... 22
Check the Gas Flame Regularly ...................................................................................... 22
Wiring Diagrams ............................................................................................................... 23
Replacement Parts ....................................................................................................................... 24
Optional Accessories .................................................................................................................. 27
Warranty ....................................................................................................................................... 30
2 2 20004409
Radiance Natural Vent Gas Heater
Installation & Operating Instructions
The Radiance Natural Vent Room Heater, Model Nos. 3340 thru 3349, 3355, 3356 is a vented gas appliance listed to the
ANSI Standard Z21.88b-2001 and CSA-2.33b-2001 for Vented
Room Heaters, and CSA 2.17-M91, Gas-Fired Appliances For
Use at High Altitudes.
The installation of the Radiance Natural Vent Room Heater must conform with local codes, or in the absence of local codes, with National Fuel Gas Code, ANSI Z223.1/NFPA 54 — latest edition and CSA B-149.1 Installation Code. (EXCEPTION: Do not derate this appliance for altitude. Maintain the manifold pressure at 3.5 inches w.c. for Natural Gas and 10 inches w.c. for LP gas at maximum input.)
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified kit is used.
Installation and replacement of gas piping, gas utilization equipment or accessories, and repair and servicing of equipment shall be performed only by a qualified agency.
The term “qualified agency” means any individual, firm, corporation, or company that either in person or through a representative is engaged in and is responsible for (a) installation or replacement of gas piping, or (b), the connection, installation, repair, or servicing of equipment, who is experienced in such work, familiar with all precautions required, and has complied with all the requirements of the authority having jurisdiction.
The Radiance Natural Vent Room Heater should be inspected before use and at least annually by a qualified service agency. It is imperative that control compartments, burners, and circulating air passageways of the appliance be kept clean.
The Radiance Natural Vent Room Heater and its individual shutoff valve must be disconnected from the gas supply piping during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).
The Radiance Natural Vent Room Heater must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig.
An accessible tap is located above the pilot/On-Off knob for checking the inlet pressure.
This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate combustion and ventilation air.
This appliance must be properly connected to a listed 4”
(100mm) Type B venting system or to an approved masonry or factory-built chimney system. In Canada, a complete reline of
Class A chimneys is required. This heater is equipped with a vent safety shutoff system.
This appliance is approved for bedroom installations in the U.S.
and Canada.
This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes.
WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death.
The Radiance Natural Vent Room Heater, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code
ANSI/NFPA 70, (latest edition), or of the current Canadian Electrical Code C22.1.
Due to high temperatures this appliance should be located out of traffic and away from furniture and draperies.
WARNING: This appliance is hot while in operation. Keep children, clothing, and furniture away. Contact may cause burns or ignition of combustible materials.
Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. Young children should be carefully supervised when they are in the same room as the appliance.
Clothing or other flammable materials should not be placed on or near the appliance.
Any safety screen, glass or guard removed for servicing an appliance must be replaced prior to operating the appliance.
The appliance area must be kept clear and free from combustible materials, gasoline, and other flammable vapors and liquids.
The flow of combustion and ventilation air must not be obstructed. The installation must include adequate accessibility and clearance for servicing and proper operation.
WARNING: Do not operate the Room Heater with the glass panel removed, cracked or broken. Replacement of the panel should be done by a licensed or qualified service person.
Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
Do not burn wood, trash or any other material for which this appliance was not designed. This appliance is designed to burn either natural gas or propane only.
This gas appliance must not be connected to a chimney flue serving a separate solid-fuel burning appliance.
CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.
Verify proper operation after servicing.
* Aftermarket: Completion of sale, nor for purpose of resale, from the manufacturer.
Proposition 65 Warning: Fuels used in gas, woodburning or oil fired appliances, and the products of combustion of such fuels, contain chemicals known to the State of California to cause cancer, birth defects and other reproductive harm.
California Health & Safety Code Sec. 25249.6
20004409 3
Radiance Natural Vent Gas Heater
CL
4 ¹⁄₂ "
(114mm)
14 ⁷⁄₈ "
(378mm)
Stove Dimensions
4" Inner Dia.
(100mm)
29 ³⁄₄ "
(756mm)
31"
(787mm)
See Page 5 for Flue Collar
Centerline Dimensions.
R A D I A N C E
28"
(711mm)
5"
(127mm)
18
¹⁄₄
"
(464mm)
9 ¹⁄₂ "
(241mm)
Supply
Inlet
4409
Fig. 1 Radiance dimensions.
4 4 20004409
Radiance Natural Vent Gas Heater
Clearance Requirements
Minimum Clearances to
Combustible Materials
Measure side clearances as shown in Figures 2 through 5 from the outer edge of the cast iron stove top. Measure rear clearances from the rear sheet metal shroud.
The Radiance heater is approved for installation into an alcove constructed of combustible materials to the dimensions and clearances shown on this page.
The same clearances apply in a standard parallel installation.
Parallel Installation: Minimum Clearance and Flue Centerline
C
D A
Ceiling Clearances
46"
(1168mm)
74"
(1880mm)
R A D I A N C E
ST131b
Fig. 4 Minimum ceiling clearance: minimum alcove height.
Alcove Minimum Dimensions
42"
(1070mm)
4"
(100mm)
B
Stove Clearance
Pipe Centerline
A: 4” (100mm)
B: 6” (150mm)
C: 21
⁷⁄₈
“ (556mm)
D: 8 ¹⁄₂ ” (216mm) ST128b
Fig. 2 Parallel installation, minimum back and side clearances, and flue centerlines.
Corner Installation: Minimum
Clearance and Flue Centerline
B
A
B
A
Stove Clearance:
Pipe Centerline:
A: 6” (150mm)
B: 18” (460mm)
Fig. 3 Corner installation requirements.
ST129b
20004409
6"
(150mm)
6"
(150mm)
Fig. 5 The Radiance Natural Vent Stove is approved for installation into alcoves built of combustible materials.
Hearth Requirements
The Radiance Heater must be installed on rigid flooring. When the heater is installed directly on any combustible surface other than wood flooring, a metal or wood panel extending the full width and depth of the unit must be used as the hearth. There are no other hearth requirements.
WARNING:
• Always maintain required clearances (air spaces) to nearby combustibles to prevent fire hazard. Do not fill air spaces with insulation. All venting components must maintain a 1" (25mm) clearance to combustible materials. Maintain a 6” (150mm) clearance when using single wall pipe.
• The gas appliance and vent system must be vented directly to the outside of the building and never be attached to a chimney serving a separate solid fuel or gas-burning appliance.
• Refer to the manufacturer's instructions included with the venting system for complete installation procedures.
5
Radiance Natural Vent Gas Heater
Gas Specifications
Model Fuel
RNVODRN Nat
Gas Control
Millivolt
Max.
Min.
Input Input
BTU/h
35,000
BTU/h
25,000
RNVODRP Prop Millivolt 35,000 27,000
Weight: Fully assembled 350 lbs.
Gas Inlet and Manifold Pressures
Inlet Minimum
Inlet Maximum
Manifold Pressure
Natural
5.5” w.c.
14” w.c.
3.5” w.c.
LP (Propane)
11” w.c.
14” w.c.
10” w.c.
Radiance Natural Vent
Certified to:
ANSI Z21.88b-2001 / CSA Z2.33b-2001
Vented Gas Fireplace Heaters
The installation must conform with local codes or, in the absence of local codes, with the National Fuel
Gas Code, ANSI Z223.1 - latest edition.
(EXCEPTION: Do not derate this appliance for altitude. Maintain the manifold pressure at 3.5” w.c.
for Natural Gas and 10” w.c. for Propane.)
High Elevations
Input ratings are shown in BTU per hour and are certified without deration for elevations up to
4,500 feet (1,370m) above sea level.
For elevations above 4,500 feet (1,370m) in USA, installations must be in accordance with the current ANSI Z223.1/NFPA 54 and/or local codes having jurisdiction.
In Canada, please consult provincial and/or local authorities having jurisdiction for installations at elevations above 4,500 feet (1,370m).
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual for correct installation and operational procedures. For assistance or additional information consult a qualified installer, service agency, or the gas supplier.
Venting Requirements and Options
The Radiance must be properly connected to a listed
4” (102mm) Type B venting system or to an approved
Class A masonry or factory-built chimney system. In
Canada, a complete relining of Class A chimney systems is required.
The Radiance Natural Vent stove will accept decorative
6” (150mm) stove pipe around the Type B venting system, for aesthetic purposes.
Complete Type B vent systems are available from a number of manufacturers, and your dealer can usually supply one. Pipe sections from different makers are not interchangeable; do not mix pipe or vent sections from different makers. Follow the vent system manufacturer’s instructions exactly.
Decorative stove chimneys for B vent applications are available through vent dealers.
The vent system should conform to specifications of the National Fuel Gas Code, latest edition.
If connecting to a Class A chimney system, use 4”
(102mm) single wall or 4” Type B vent connector.
Single wall vent connector requires a minimum 6”
(153mm) clearance to combustible surfaces.
Exterior chimneys may be subject to flow reversal or condensation. To lessen these conditions, enclose
Type B vents in an insulated chase, or reline exterior
Class A chimneys.
An approved pass-through device is always required, whether the vent system passes through a wall or a ceiling. Use a pass-through device from the same maker who supplies the venting system.
Venting terminals shall not be recessed into a wall or siding.
Vent Layout and Height Requirements
Venting for a Radiance can rise vertically through the home, or can pass through an exterior wall and rise along the outside of the home. Some codes require that a Type B vent system rising on the outside of the home be enclosed in a chase. Check your local codes for requirements.
The minimum vent system height for the Radiance
Natural Vent Stove is 8 feet (2.43m), (Fig. 7) measured from the top of the stove. To determine the minimum height the vent system must extend through or past the roof, refer to the 1993 edition of the National Fuel Gas
Code.
6 6 20004409
Radiance Natural Vent Gas Heater
Passing Through a
Combustible Wall or Ceiling
An approved pass-through device is always required when a vent passes through a combustible wall or ceiling. Check with the maker of the vent system for the correct listed devices that are available. A listed pass-through device is required whether or not the installation includes decorative pipe around the Type B venting system. NOTE: It is essential to seal between the ceiling support (sometimes called a ‘firestop spacer’) and the decorative pipe, if installed, with a high-temperature silicone sealant. (Fig. 6)
Complete the venting system installation according to the manufacturer’s instructions.
Joists Air Space as
Required by
Code
Ceiling
Support
Hightemperature
Silicone Sealant
Decorative
6” Pipe
Trim
Collar
Hightemperature
Silicone
Sealant
ST361
Listed 4”
(102mm)
B-Vent
Air Space
Fig. 6 A ceiling pass-through, with decorative pipe around the vent.
Venting Requirements
12
10
8
6
20
18
16
14
4
2
28
26
24
22
36
34
32
30
A
B
1 2 4 6 8 10 12 14 16 18 20 22 24
Horizontal Run (in feet)
Venting Runs
NOTE: When venting staight vertical, without an elbow, a minimum of 8 ft. vertical is required off the top of the stove.
= Acceptable venting configuration
= Unacceptable venting configuration
A: Vertical installations up to 36 feet (12m) in
height. Up to an 18 ft. horizontal vent run can be
installed within the vent system using a
maximum of two 90-degree elbows or four
45-degree elbows.
B: Vertical installations up to 36 feet (12m) in
height. Up to a 24 ft. horizontal vent run can be
installed within the vent system using a
maximum of two 45-degree elbows.
(Ratio = 2/3, Hor./Vert.)
FP567b
Fig. 7 Vent termination window.
20004409 7
Radiance Natural Vent Gas Heater
Tools Required
Assembly Procedures
CAUTION: To prevent valve tubing from being crushed or damaged, make sure to rest valve on wooden pallet.
• Phillips screwdriver (stub)
• utility knife
• power drill
• reciprocating saw
• metal drill bit: size 28 (.140"/3.5mm)
Unpack and Set Up the Stove
The Radiance is shipped on its back. Cut the shipping straps and set stove upright.
Parts Bag Contents:
• On-Off switch, housing, and wiring harness
• 2 Bags of Lava Rock
• Pipe Support Bracket •
• 7 Screws
Fan Bracket*
• Door Handle (Operable) • Control Door Handle
• Owner Registration Card
• (4) CS, Hex Hd 3/8-16 x 1 GR 2-Z
• (4) Washer, FL 3/8-Z
*Used with stove’s having serials #’s starting at #1457
(RNVODRN), #1944 (RNVODRP).
Unpack and Assemble Legs
The Radiance is shipped upright. Cut the shipping straps and set stove upright.
1. Slide stove to the rear of the pallet just far enough to access rear leg holes. Make sure the stove does not tip over backwards. (Fig. 8)
ST721
Washer
Hex Head Bolt
Fig. 9 Carefully tip stove onto back legs. Leave pallet under stove to keep stove from falling fully forward.
4. Have your assistant attach one leg using the hardware described.
5. Move the pallet to allow access to the other front leg hole. Attach remaining leg.
6. Remove pallet and allow stove to gently rest on all four legs.
7. Adjust leg levelers to compensate for irregularities in the hearth.
WARNING
This appliance is equipped with a three-prong
(grounded) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug.
ST720
Fig. 8 Slide stove back just far enough to access rear leg holes.
2. Attach the rear legs using 3/8” hex head bolts and flat washer supplied. Tighten with a 9/16” wrench or socket.
3. Carefully tip the stove onto its rear legs. Adjust the pallet to allow access to one of the front leg holes.
Be sure to leave the pallet under the stove to prevent the stove from falling fully forward. (Fig. 9)
8 8
Install the Optional Fan
These instructions are for stoves with serial numbers up to #1456 (RNVODRN), #1943 (RNVODRP).
If you are installing the optional convection Fan Kit
#2767 (FK26), continue here. It is easiest to install fan kit before connecting gas line. If you are not installing a
Fan Kit, proceed to Venting System Assembly.
20004409
Radiance Natural Vent Gas Heater
1. The fan kit includes a Blower Assembly and a
Rheostat Assembly, connected by a cable. (Fig. 10)
The Blower Assembly mounts to the bottom rear of the stove, and the Rheostat mounts to the left side of the valve. The assembly includes a 'snapstat' which automatically turns the fan On (or Off) above (or below) approximately 109˚F. The Rheostat also provides a range of fan speed settings from Off
(which overrides the snapstat function) to High.
Unpack and inspect the Blower assembly. Confirm that the fan spins freely.
Snapstat
Assembly
Not Used
On
Radiance
Rheostat
Assembly
ST146
Fig. 10 Fan kit components.
2. Remove the rear shroud. (Fig. 11) Use work gloves to protect your hands. Remove the rear shroud cover plate. Remove the six sheet metal screws (‘A’, Fig. 9) surrounding the draft hood opening. Remove the shroud and set it aside.
Rear
Shroud
A
Rear shroud
Cover Plate
(Shipping
Position)
ST363
Fig. 11 Remove/replace rear shroud.
3. Position the fan behind the rear shroud. (Fig. 12)
Pass the fan rheostat assembly and snapstat assembly beneath the stove toward the front.
4. The rheostat control switch attaches to the left side of the valve bracket at the front of the stove. (Fig. 14)
• Remove the plug from the rheostat bracket.
• Insert the switch box shaft through the hole in the back of the right side of the valve bracket, aligning the locator pin with the smaller hole in that bracket.
• Attach the control knob to the rheostat shaft.
• Use the wire tie to secure the fan and rheostat wire harnesses together.
1/4”-
20x1/2”
Hex Bolts
Star
Washer
Snapstat
Housing
Snapstat
Bracket
Slot
Fan Shield
Hex Nuts
Edge ‘A’
ST369
Fig. 12 Position fan behind rear shroud.
5. Attach the snapstat housing to the snapstat bracket with two sheet metal screws and one #8 star washer.
(Fig. 12)
6. Attach the snapstat bracket, with the snapstat assembly attached to it, to the horizontal surface on the inside of the rear shroud. Use a sheet metal screw.
There are predrilled holes at each corner of the panel for this. The vertical part of the snapstat bracket should be 3/16” back from Edge ‘A’. (Fig. 12)
7. Attach the fan assembly to the rear shroud using two
1/4”-20 x 1/2” hex head bolts, two 1/4” -20 nuts and one 1/4” star washer. (Fig. 12)
8. Reattach the stove’s rear shroud.
9. Reattach the rear shroud cover plate by fastening it to the rear shroud as shown in Figure 13. The top edge of the cover plate goes inside the rear shroud. Reinstall and tighten the six sheet metal screws around the draft hood opening; see ‘A’, Figure 13. Use two screws from the fan kit to fasten the rear shroud to the fan shield; refer to ‘A’, Figure 13.
Plug the fan cord into a standard grounded 110 volt household outlet.
20004409 9
Radiance Natural Vent Gas Heater
Rear Shroud
Cover Plate
A
A
ST371
Fig. 13 Attach rear shroud cover plate to the rear shroud.
Rheostat
Rheostat
Retaining Collar
Rheostat Knob
Fig. 14 Attach the fan rheostat.
ST347a
Install the Optional Fan
These instructions are for stoves with serial numbers starting at #1457 (RNVODRN), #1944 (RNVODRP).
If you are installing the optional convection Fan Kit
#2767 (FK26), continue here. It is easiest to install fan kit before connecting gas line. If you are not installing a
Fan Kit, proceed to Venting System Assembly.
1. The fan kit includes a Blower Assembly and a
Rheostat Assembly, connected by a cable. The
Blower Assembly mounts to the bottom rear of the stove, and the Rheostat mounts to the left side of the valve. The assembly includes a 'snapstat' which automatically turns the fan On (or Off) above (or below) approximately 109˚. The Rheostat also provides a range of fan speed settings from Off
(which overrides the snapstat function) to High.
Unpack and inspect the Blower assembly. Confirm that the fan spins freely.
2. Loosen the four phillips head screws which secure the rear shroud to the stove sides. (Fig. 15)
3. Carefully pull the shroud assembly away from the rear of the stove.
4. With the rear shroud assembly in the upright position, set the bottom of the shroud on a padded surface to prevent scratching the surface. Unfasten the four phillips head screws which attach the outer shroud to the inner duct assembly.
10 10
Rear
Shroud
Assembly
ST713
Fig. 15 Remove rear shroud.
5. Attach the fan assembly to the fan bracket provided in the finish bag. Use the #10 sheet metal screws provided with fan kit. Do not remove finger guard screws. (Fig. 16)
Snapstat
Wire
Rheostat
Wire
Fan
Bracket
ST669 Finger Guard
Fig. 16 Attach the fan assembly to the fan bracket.
6. Connect snapstat leads. Disconnect the snapstat module from the leads inside the snapstat bracket.
(Fig. 17) Bend open the snapstat bracket. Use needle nose pliers to remove the black plastic grommet from the bracket. Discard the bracket.
Insert the grommet and wires into the large hole at the bottom right corner of the inner shroud. Feed the snapstat wire leads through the grommet into the stove interior. Connect the two wires to the two snapstat extension leads attached to the inner shroud or, on some models, in between the inner and outer shroud.
7. Position the fan assembly so the ducts slide between the inner and outer shroud. The inner shroud should engage with the two slots in the ends of the bracket so that bracket and shroud are interlocked. (Fig. 18)
Secure the bracket with the four sheet metal screws provided in the finish bag.
20004409
Snapstat Bracket
Snapstat Module
Pinch
Grommet to
Remove
Left Air Duct
Radiance Natural Vent Gas Heater
Snapstat
ST671
Fig. 19 Install the snapstat and connect the extension wire terminals. View is with top removed, however, access is available through the rear when installing fan befoe gas line connection.
ST670
Fig. 17 Remove the snapstat and grommet from the bracket and insert the grommet into the inner shroud.
Outer
Shroud
Slot
Inner Shroud
Slot
ST194
Fig. 18 Position the fan to engage the inner shroud with the fan bracket slots and secure with sheet metals screws.
8. Route the rheostat wire assembly to the right between the inner and outer shroud. Run the wire through the slots at the bottom right corner of the inner shroud. Some models have the extension wire assembly attached to the inner shroud.
9. Refasten the outer shroud to the inner duct assembly.
10. Install the snapstat by loosening the front screw on the inner side of the duct (Fig. 19) slide the snapstat under the head of the screw and tighten. Connect the leads to the snapstat. Make sure the snapstat assembly is mounted straight front to back.
11. Slide shroud assembly over the sides and fasten the four screws loosened earlier.
12. The rheostat control switch attaches to the left side of the valve bracket at the front of the stove. (Fig. 20)
• Remove the plug from the rheostat bracket.
• Insert the switch box shaft through the hole in the back of the right side of the valve bracket, aligning the locator pin with the smaller hole in that bracket.
20004409
Retaining Nut
Control Knob
ST347a
Fig. 20 Attach rheostat to left side of valve.
• Attach the control knob to the rheostat shaft.
• Use the wire tie to secure the fan and rheostat wire harnesses together.
12. Plug the power cord into a standard grounded 110 volt household outlet. If the fan control knob is not turned to the OFF position, the fan will turn on when the temperature at the snapstat reaches approximately 109
°
F.
MOTOR
BLK SNAPSTAT
BLK WHT
ON/OFF
RHEOSTAT
POWER
Fig. 21 #2767 / FK26 Fan wiring diagram.
ST196
11
Radiance Natural Vent Gas Heater
Venting System Assembly
Adjust the leg levelers as needed. They should not extend any further from the leg than necessary.
The venting collar is on the sheet metal draft hood/heat exchanger assembly, over the firebox. Use a B-vent adapter, from the same maker as the rest of the B-vent components, to join the first section of venting to the draft hood.
The RNVOD stove includes a vent safety switch.
Operating this stove when not connected to a properly installed and maintained venting system, or tampering with or disconnecting the vent safety switch can result in carbon monoxide (CO) poisoning and possible death.
The stove includes a bracket for installing decorative 6 inch (150mm) round stove pipe around the B-vent, for appearance purposes only. The decorative pipe need not be concentric with the vent pipe.
If the installation includes decorative stove pipe around the venting system, make a cardboard template of the decorative pipe by tracing its circumference. Put this template in the flue recess in the stove top. Position the template to fit well against the front of the recess.
(Fig. 22) Use this template to locate the bracket to hold the decorative pipe Depending on spacing, the bracket may fit inside the decorative pipe without interfering with the vent system. Fasten the bracket to the draft hood/heat exchanger assembly with a sheet metal screw.
Template
Sheet Metal
Screws
Bracket do not need to be fastened at each joint, other than slip sections. The decorative pipe need not be fastened to the locating bracket on the stove. If the layout includes a slip section, this should be the last section of pipe visible in the room at the ceiling. Refer to Page 7,
Figure 6, for details on joining the decorative pipe at the ceiling.
ST373
Fig. 23 Attach the B-vent adapter to the flue.
B-vent Pipe
Decorative Pipe
7FSSK Bracket
Fig. 24 Install decorative pipe over the B-vent pipe.
ST374
ST372
Fig. 20 Use a template to locate the bracket for decorative pipe to surround the B-vent pipe.
Insert the B-vent adapter into the flue collar and drill
1/8” (3mm) pilot holes through both the stove’s collar and the adapter. Attach the adapter to the flue collar with sheet metal screws. (Fig. 21)
Attach the first section of venting to the B-vent adapter.
Depending on the length of the individual venting sections and the lengths of the decorative pipe, you may need to slip the decorative pipe over the venting sections before attaching upper sections to lower ones.
The sections of decorative pipe should be oriented with their seams (if any) toward the wall; sections usually
12 12 20004409
Radiance Natural Vent Gas Heater
Connect the Gas Supply Line
Check the Rating Plate attached by a steel cable to the firebox, to confirm that you have the appropriate firebox for the type of fuel to be used. The Radiance may be converted from one gas to another using the appropriate Fuel Conversion Kit listed on Page 26.
CAUTION
This appliance should only be connected by a qualified gas technician. Test to confirm manifold pressures as specified below.
The Radiance Heater and its individual shutoff valve must be disconnected from the gas supply piping during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).
The Radiance Heater must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressure equal to or less than 1/2 psig.
There must be a gas shutoff between the stove and the supply.
In order to connect Natural Gas, use a fitting with a 3/8” NPT nipple on the valve side and 1/2” natural gas supply line with an input of 35,000
BTUs at a manifold pressure of 3.5” and a minimum inlet supply pressure of 5.5” w.c.
In order to connect Propane, use a fitting with 1/2”
NPT on the valve side and 1/2” propane gas supply line with an input of 35,000 BTUs at a manifold pressure of 10.0” and a minimum inlet supply pressure of 11.0” w.c.
In the U.S.; Gas connection should be made in accordance with current National Fuel Gas Code, ANSI
Z223.1. Since some municipalities have additional local codes, be sure to consult you local authority.
In Canada; consult the local authority and CSA-B149.1
installation code.
Connect the gas supply and test for leaks. Use a 50/50 solution of liquid soap and water to test for leaks at gas fittings and joints. Apply water/soap solution with brush only - do not over apply. NEVER test with an open
flame. Light the pilot according to the directions on page 16, before going to the next step.
Burner Information
The appliance must only use the gas specified on the rating plate, unless converted using a Fuel Conversion
Kit. To convert from LP to Natural Gas use Kit #000-
5009. To convert from Natural Gas to LP use Kit #000-
5010.
Conversion instructions are provided with each kit and beginning on Page 19 in this manual.
THIS APPLIANCE SHOULD BE CON-
NECTED TO THE GAS SUPPLY ONLY BY A
QUALIFIED GAS SERVICE TECHNICIAN.
FOLLOW ALL LOCAL CODES.
THERE MUST BE A GAS SHUT-OFF BE-
TWEEN THE STOVE AND THE SUPPLY.
In order to connect Natural Gas, use a fitting with a
3/8” NPT nipple on the valve side and 1/2” natural gas supply line with an input of 35,000 BTUs at a manifold pressure of 3.5” and minimum inlet supply pressure of
5.5” w.c.
In order to connect Propane, use a fitting with a 3/8”
NPT nipple on the valve side and 1/2” propane gas supply line with an input of 35,000 BTUs at a manifold pressure of 10.0” and minimum inlet supply pressure of
11.0” w.c.
Install ON/OFF Switch
The switch assembly parts are found in the parts bag.
1. Attach switch assembly to left rear side of stove shroud (when facing shroud) using two screws and existing holes in shroud. (Fig. 25)
2. Run wires down back of stove, under bottom of rear shroud to valve.
3. Attach wires to valve terminals. (Fig. 26)
Switch
Assembly
Existing
Holes
Screws
ST315
Fig. 25 Attach switch assembly to rear shroud.
20004409 13
Radiance Natural Vent Gas Heater
Install Rear Bracket and Log Set
1. Remove the logs from their packaging, and inspect each piece for damage. DO NOT INSTALL DAM-
AGED LOGS.
Rear Log
Bracket
ST228
Fig. 26 Attach switch wires to valve.
Thermostat Connection (optional)
Use only a thermostat rated for 500 - 750 millivolts.
Check the table below for the appropriate gauge thermostat wire to use for the length of lead required in your installation.
Thermostat
Wire / Gauge
18
20
22
Maximum Run
40 feet
25 feet
16 feet
1. Install the wall thermostat in the desired location and run the wires to the stove location. Terminate these leads with 1/4” female connectors.
2. Connect the thermostat wires to the valve. (Fig. 26)
Install the Mesh and Grille
Place the mesh and grille on the top of the Radiance stove to complete assembly.
LG158
Fig. 27 Radiance firebox and rear log bracket.
2. Install the left rear log by placing it on the rear log bracket at the back of the firebox. (Fig. 28) The left rear log should touch the back wall of the firebox.
Slide the left rear log to the left until the left side lines up with the left bracket. (Fig. 28) When the left rear log is in place the front left corner of the log should rest on the decorative grate.
3. Install the right rear log by placing it on the rear log bracket at the back toward the right. Make sure the right side of the right rear log lines up with the right bracket. (Fig. 29) NOTE: When the right and left rear logs are in place, they should touch the back of the firebox and each other.
4. Install the right log by engaging hole on the bottom left of the right log with pin on the front left of the right rear log. (Fig. 29) Set the bottom right of the right log on the bracket and bring the bottom right forward to come in contact with decorative grate on the right.
5. Loosely sprinkle the lava rocks directly on top of the burner just behind decorative grate. Use the lava rock to cover brackets on the burner. Do not place lava rocks toward back of burner. The lava rock is shipped inside the finish bag assembly. (Figs. 29,
30)
14 14 20004409
Radiance Natural Vent Gas Heater
Left Rear Log
Top View Right Rear
Log Right Rear Log
Left Rear Log
Right Log
Left
Bracket
Decorative
Grate
Right
Bracket
LG156
Fig. 28 Install the left and right rear logs and the right log.
Decorative
Grate
NOTE: Right log is not shown in this view.
Lava Rock may be placed in this area
LG160
Fig. 30 Place lava rock on top of burner just behind decorative grate.
Log rests on decorative grate
Fig. 29 Completed log installation.
Lava Rock LG155
20004409 15
Radiance Natural Vent Gas Heater
Operation
Operable Doors
The Radiance is shipped with the operable door front.
The stove may be operated with the doors either open or closed. To open the front doors, insert the handle into the door latch stub and turn it to the right and up.
(Fig. 31) When not in use, the handle may be stored in the handle holder on the right side of the rear shroud.
(Fig. 32)
Counterclockwise to Open
ST621a
Fig. 31 To open the front doors, turn handle counterclockwise.
Clockwise to Close
Pilot Assembly
ST476
Fig. 33 Pilot Assembly location.
Turn counterclockwise to decrease flame height
LO
HI
Turn clockwise to increase flame height
HV102
Fig. 34 Flame adjustment knob for Honeywell valve.
RADIANCE
Handle
Holder
Flame Characteristics
It is important to periodically perform a visual check of the pilot and burner flames. Compare them to Figures
35 and 36. If the flame patterns appear abnormal contact a qualified service provider for service and adjustment.
ST656
Fig. 30 When not in use, store handle in the handle holder.
Your First Fire
Read these instructions carefully and familiarize yourself with the burner controls shown on Page 16.
Locate the pilot assembly, Figure 33. Follow the lighting instructions on Page 17 exactly.
During the first fire, it is not unusual to smell some odor associated with new logs, paint and metal being heated. Odors should dissipate within an hour or so, however, you can open a window to provide fresh air to alleviate the condition.
Pilot and Burner Inspection
Each time you light your heater check that the pilot flame and burner flame patterns are as shown in
Figures 35 and 36. If flame patterns are incorrect, turn the heater off. Contact your dealer or a qualified gas technician for assistance. Do not operate the heater until the pilot flame is correct.
Flame & Temperature Adjustment
For units equipped with HI/LO valves, the flame adjustment is accomplished by rotating the HI/LO knob located near the center of the gas control valve. (Fig. 34)
Fig. 35 Correct pilot flame pattern. SIT pilot.
Red Glow
Fig. 36 Correct burner flame pattern.
CO105c
LG157
16 16 20004409
Radiance Natural Vent Gas Heater
Lighting and Operating Instructions
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING:If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
A. This heater has a pilot which must be lit manually. When lighting the pilot follow these instructions exactly.
B. BEFORE LIGHTING smell all around the heater area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any fireplace
• Do not touch any electric switch
• Do not use any phone in your building
• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the
Fire Department
C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it, call a qualified service technician. Applying force or any attempted repair may result in a fire or explosion.
D. Do not use this fireplace if any part has been under water. Immediately call a qualified service technician to inspect the heater and to replace any part of the control system and any gas control which has been under water.
Lighting Instructions
1. STOP! Read the safety information above.
2. Turn off all electrical power to the fireplace.
3. For MN/MP/TN/TP appliances ONLY, go on to
Step 4. For RN/RP appliances turn the On/Off switch to “OFF” position or set thermostat to lowest level.
4. Open control access panel.
5. Push in gas control knob slightly and turn clockwise to "OFF".
OFF
PILOT
PILOT ilo t
5
4
1
2
3
F
OFF
10. Push the control knob all the way in and hold.
Immediately light the pilot by repeatedly depressing the piezo spark ignitor until a flame appears. Continue to hold the control knob in for about one (1) minute after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 8.
3/8" - 1/2"
Euro SIT SIT NOVA Honeywell
6. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above. If you do not smell gas, go to the next step.
7. Remove glass door before lighting pilot. (See
Glass Frame Removal section).
8. Visibly locate pilot by the main burner.
9. Turn knob on gas control counterclockwise
to "PILOT".
• If knob does not pop up when released, stop and immediately call your service technician or gas supplier.
• If after several tries, the pilot will not stay lit, turn the gas control knob to "OFF" and call your service technician or gas supplier.
11. Replace glass door.
12. Turn gas control knob to “ON” position.
13. For RN/RP appliances turn the On/Off switch to
“ON” position or set thermostat to desired setting.
14. Turn on all electrical power to the fireplace.
To Turn Off Gas To Heater
1. Turn the On/Off switch to Off position or set the thermostat to lowest setting.
2. Turn off all electric power to the fireplace if service is to be performed.
3. Open control access panel.
4. Push in gas control knob slightly and turn clockwise to "OFF". Do not force.
5. Close control access panel.
20004409 17
Radiance Natural Vent Gas Heater
Troubleshooting / Honeywell #8420 Gas Control System
NOTE: Before troubleshooting the gas control system, be sure the external gas shutoff is in the “ON” position.
WARNING: REMOVE THE GLASS PANEL BEFORE PERFORMING ANY GAS CONTROL SERVICE WORK.
SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION
1. Spark ignitor will not light
2. Pilot will not stay lit after carefully following the lighting instructions
3. Pilot lights, no gas to burner, valve knob ON, remote switch (rocker switch) ON
4. Frequent pilot outage
A. Defective or misaligned electrode at the pilot
B. Defective ignitor (push button)
A. Defective pilot generator
(thermocouple)
B. Defective automatic valve operator
C.Defective safety switch
A. Remote switch or wires defective
B. Thermopile may not genate sufficient voltage
C. Plugged burner orifice
D. Defective automatic valve operator
A. Pilot flame may be too low or high, (blowing or lifting).
causing the pilot to drop out
B. Possible blockage of the vent terminal
Using a match, light [ilot. If pilot lights, turn off pilot and push the ignitor button again. If pilot will not light, check gap at electrode and pilot - it should be 1/8” to have a strong spark.
Push piezo ignitor button. Check for spark at electrode and pilot. If there is no spark at the pilot, and electrode wire is properly connected, replace ignitor.
Check pilot flame. It must impinge on the thermocouple or thermopile. NOTE: This pilot burner assembly uses both a thermocouple adn a thermopile. The thermocouple operates the pilot flame. Tighten the thermocouple. The thermopile operates the main valve. (ON and OFF) Clean and/or adjust pilot for maximum flame impingement on thermocouple and thermopile.
Turn valve knob to “Pilot”. Maintain flow to pilot; millivolt mete should read greater than 10mV. If the reading is okay and the pilot does not stay on, replace the gas valve. NOTE: An interrupter block (not supplied) must be used to conduct this test.
Check the continuity accross the safety limit switch with the unit cold. If there is no continuity, the safety switch needs to be replaced.
Check rocker switch and wires for proper connection
Use jumper wires across terminals at rocker switch. If burner lights, replace rocker switch. If okay, use jumper wires across rocker switch wires at the valve. If burner lights, wires are faulty or connections are bad.
1. Be sure wire connecitons from thermopile at gas valve terminals are tight and thermopile is fully inserted into pilot bracket.
2. One of the rocker switch wires may be grounded
Remove rocker switch wire form valve termianls. If burner now stays lit, trace rocker switch wiring from ground. It may be grounded to the appliance of the gas supply line.
3. Check the thermopile with a millivolt meter. Take reading at thermopile (“TP” and “TP/TH”) terminals of gas valve. Should read 325 millivolts minimum while holding valve knob depressed in PILOT position and with rocker switch OFF. Replace faulty thermopile if reading is below specified minimum.
Check burner orifices for debris, and remove.
Turn knob to ON, place rocker switch to ON. Millivolt meter should read greater than 10mV. If the reading is okay and the burner does not light, replace the valve.
Clean and/or adjust pilot flame for maximum flame impingement on thermocouple and thermopile.
Check the vent termianl for blockage.
18 18 20004409
Radiance Natural Vent Gas Heater
Fuel Conversion Instructions
WARNING! This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life. The qualified service agency is responsible for the proper installation of this kit. The installation is not proper and complete until the operation of the converted appliance is checked as specified in the manufacturer’s instructions supplied with the kit.
CAUTION: The gas supply shall be shut off prior to disconnecting the electrical power, before proceeding with the conversion.
6. Remove the right and left log bracket assembly by unfastening the two screws which hold the burner in place. (Fig. 38)
Remove Screws
Rear Log Bracket
Pilot
PILOT
OFF
Left & Right Log
Bracket Assembly ST350
Fig. 38 Remove rear log bracket and left and right log bracket assembly.
7. Hold the burner at the right hand side and lift to clear the right burner leg. Then pull to the right to clear the injectors on the left hand side.
8. Remove injector orifices from left burner leg using
1/2” wrench. (Fig. 39)
9. Install conversion orifices. (Refer to Table 1)
10. Remove cap from HI/LO knob. This can be accomplished by lifting the plastic cap off the screw. (Fig.
40)
11. Remove the screw from center of HI/LO knob with small screwdriver turning counterclockwise. (Fig. 40)
Main
Gas Line
Gas Supply Inlet
ST226
Fig. 37 Attach the gas line to the left side of the valve.
Conversion Precautions
This conversion must only be completed by qualified personnel. Before proceeding, turn control knob on valve to OFF and turn gas supply OFF. Turn OFF any electricity that may be going to the appliance.
Caution: Allow stove to cool completely before beginning conversion.
Conversion Procedure
1. Remove stove front. Lift stove front up and then swing bottom out and away to disengage from the stove body. (Page 22, Fig. 44)
2. Undo the right and left latches at the top of the glass frame. (Page 22, Fig. 45)
3. Pull the top edge of the glass and frame assembly away from the firebox face. Place the assembly out of the way on a flat, padded surface such as a counter protected by a towel.
4. Remove the logset from the firebox.
5. Remove the rear log bracket by unfastening the screw and pulling the bracket away. (Fig. 38)
90¡
Left Burner Leg
Injector Orifices
Fig. 39 Remove and replace injector orifices.
Cap
HI
Lift Open
L O
Hi-Lo
Knob Center Screw
Fig. 40 Remove center screw from HI/LO knob.
HI
L O
ST353a
CO100
20004409 19
Radiance Natural Vent Gas Heater
12. Insert blue painted screw when converting to natural gas and red painted screw when converting to LP.
13. Tighten screw (do not over tighten), replace cap.
14. Locate pilot. (Fig. 38)
15. Replace pilot orifice.
• Remove pilot hood by lifting up. (Fig. 41) NOTE: It is not necessary to remove the pilot tube for conversion.
Pilot Hood
Pilot
Bracket
CO105a
Fig. 41 Remove pilot hood.
• Remove pilot orifice with allen wrench. (Fig. 42)
• Install the conversion orifice.
• Reinstall pilot hood. Be sure to align hood with index tab.
Index Tab
Allen Wrench
16. Air shutter adjustment. The unit is shipped from the factory with the air shutter open 1”. For LP units only, the air shutter could be closed further. Refer to Table
3 for minimum air shutter opening. The air shutter is located on the bottom of the burner to the left. (Fig.
43)
17. Replace burner. Slide the burner in at an angle with left side lower than the right side. Slide the left side onto the injectors, making sure the burner leg remains at a 90
°
angle to the base. Lower the right hand side down in to place. Make sure the burner is as far left as possible and the injector shoulders are inside the burner.
NOTE: It is very critical to keep the left burner leg, which holds the injectors, at a 90
°
angle to the base.
(Fig. 39) This keeps the orifices aligned with the tubes inside burner. Failure to do so could affect the flame appearance and performance of the unit.
18. Place conversion label on valve.
19. Reinstall the right and left log bracket assembly.
20.Reinstall the rear log bracket.
21. Replace logs.
22.Replace glass and stove front.
Conversion is complete.
Refer to Table 2
Bottom of Burner Pan
Snap Ring
CO106a
Fig. 42 Remove pilot orifice.
Kit #
000-5009
ST667
Fig. 43 Adjust air shutter on bottom of heater, Refer to
Table 2 for correct position.
Table 2. Injector Orifice Size Matrix
Front
#51
Conversion to Natural Gas
Part # Rear Part #
30000449 #40
Input (BTU/h)
Minimum
20004263 25,000
Maximum
35,000
20 20
Kit #
000-5010
Front
#57
Conversion to LP
Part # Rear
20004587 #54
Part #
Input (BTU/h)
Minimum
20000130 27,500
Maximum
35,000
Table 3. Air Shutter Adjustment
Model
RNVOD
Minimum rear injector air inlet openings.
Natural Gas
1 ¹⁄₂ ”
LP
Fully Closed
20004409
Radiance Natural Vent Gas Heater
Maintenance
Your Radiance Gas Heater will provide years of service with minimal upkeep. The following procedures will help ensure that your stove continues to function properly.
Annual System Inspection
CAUTION
TURN THE PILOT OFF BEFORE PAINTING.
ALLOW THE HEATER TO COOL COMPLETELY
BEFORE PAINTING.
Have the entire heater and venting system inspected annually by a qualified gas technician. Replace any worn or broken parts.
Cleaning the Glass
Logset and Burner
Cleaning and Inspection
WARNING: Let the glass cool completely before attempting to clean.
Cleanliness is critical to the proper function of the heater. The logset and burner must all be kept free of dust and unobstructed by debris. Inspect these areas before each use and clean as necessary.
1. Turn the burner OFF and let the heater cool completely before cleaning.
2. Lift the Stove Front up and then swing the bottom out to disengage it from the heater shell. (Fig. 44)
3. Carefully remove the glass and frame assembly and place it out of the way on a flat, padded surface such as a counter protected by a towel.
4. Carefully inspect the Logs for damage. Contact your local dealer if any damage is evident.
5. Use a soft bristled brush to sweep dust or debris from the Logs, Pilot and Burner. Use care as the logs are fragile and susceptible to damage.
6. Replace the glass panel and frame assembly.
7. Replace the Stove Front.
It will be necessary to clean the glass periodically.
During start-up, condensation, which is normal, forms on the inside of the glass and causes lint, dust and other airborne particles cling to the glass surface. Also initial paint curing may deposit a slight film on the glass.
It is therefore recommended that the glass be cleaned two or three times with a non-ammonia household cleaner and warm water (we recommend gas fireplace glass cleaner). After that the glass should be cleaned two or three times during each heating season depending on the circumstances present.
Clean glass after first two weeks of operation.
Glass Replacement
Replace glass only with CFM Specialty Home Products approved parts. Refer to Page 25 for Replacement
Parts. Refer to Figure 43 for removal of the damaged glass frame.
Care of Cast Iron
An occasional dusting with a dry rag will help keep the painted surfaces looking new. Use high-temperature stove paints, available through your local dealer, to touch-up areas as needed. Clean areas to be painted with a wire brush and be sure to cover the logs, burner and valve assembly, glass and frame assembly. Apply the paint sparingly; two light coats of paint will give better results than a single heavy coat.
Clean porcelain enamel surfaces with a soft, damp cloth. Do not use abrasive cleaning agents. If necessary, use only a cleaning agent formulated especially for use on porcelain enamel surfaces.
ST139
Fig. 44 Remove the Stove Front.
20004409 21
Radiance Natural Vent Gas Heater
ST141
Fig. 45 Release the latches to remove the glass frame.
Gasket Replacement
The Radiance Gas Heater uses a ‘tadpole’ type gasket to seal between the glass panel and the frame. In time, this gasket can become brittle and compressed and should be replaced. New gasket is available from your dealer.
Shut off the gas supply and allow the stove to cool.
Wear safety goggles and a dust mask.
1. Remove the Front, Glass Frame and Glass Panel.
(Figs. 44 & 45) Remove the old gasket. Use a razor blade, with rounded corners, to separate the glass and gasket from the frame, and to clean the glass of any remaining cement or bits of gasket.
2. Determine the correct length of gasket by laying it out around the edge of the glass. Allow an extra 1 -
2” (25-50mm). Mark the spot to be cut. Use a utility knife.
3. Starting on a long edge, remove about 6” of the protective paper strip and apply the flat adhesive face of the gasket around the outside-facing edge of the panel. Continue around the panel, applying about 6” at a time being careful not to stretch the material. Do not overlap the gasket ends. (Fig. 46)
4. Apply a thin bead of high temperature silicone rubber sealant along the inside corner of the glass frame, all around the perimeter. Place the flat gasketed side of the glass panel back into the steel frame. Pinch the rounded inside-facing gasket material to bulk it up.
5. Replace the glass frame and front panel as previously described.
ST179
Fig. 46 Wrap the gasket material around the outside edge of the glass.
Inspect the Vent System Annually
Have the vent system inspected annually by a qualified technician. Shut off the main gas supply before inspecting the system. Both the inner exhaust pipe and the outer combustion supply pipe must be checked to confirm that they are unblocked and in good condition.
Check the Gas Flame Regularly
To ensure that the stove is operating properly, check the flames periodically to confirm that they match
Figure 47. The flames will be blue during the first 15-20 minutes of operation, and will gradually turn to yellow after that.
Do not use your stove if the flame pattern differs from that shown here. Contact your Vermont Castings dealer or a qualified technician for help.
Red Glow
Fig. 47 Correct flame pattern.
LG157
22 22 20004409
Radiance Natural Vent Gas Heater
On/Off Switch
Wiring
Wiring Diagrams
OFF ON
POWER
CORD
FAN
TP/TH
TP
TH
Black
Optional Thermostat
Wiring
TP/TH
TP
TH
Black
Fig. 48 On/off switch and optional thermostat circuit.
ST124c
NOTE: IF ANY OF THE ORIGINAL WIRE, AS SUP-
PLIED WITH THE APPLIANCE, MUST BE RE-
PLACED, IT MUST BE REPLACED WITH TYPE SF-
2, 200
°
C WIRE OR ITS EQUIVALENT.
Safety Limit
Switch
Valve
Thermostat
(Optional)
ST124b
ST665
Chassis
Ground
BLK
WHT BLK
GRN
BLK
BLK
FAN JUNCTION BOX
Strain Relief
ON / OFF
Rheostat
Snapstat
BLK
WHT
BLK
GRN
Chassis Ground RHEOSTAT / SNAPSTAT
BOX
ST153
Schematic Diagram
MOTOR
BLK
ON/OFF
RHEOSTAT
BLK
WHT
SNAPSTAT
ST234
Fig. 50 Stardance Fan circuit.
Fig. 49 Safety Limit Switch wiring.
20004409 23
Radiance Natural Vent Gas Heater
4
1a
6
7
2
1b
1c
8a,b,c,d
9a,b
10
11
3
12
15a,b
16
5
7a,b
PILO
T
OFF
HI
21
17
22 23
18a,b
13
14
35
19
26a,b, c,d
25
24
34
29
27
20
39
28
40
31
32
36 33a
30
33b
42
41 38
37
43
4409
CFM Specialty Home Products reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice.
Radiance Natural Vent Gas Heater (RNVOD)
Models: 03340 thru 3349, 3355, 3356
20004409 24 24
Radiance Natural Vent Gas Heater
Radiance Natural Vent (RNVOD)
(continued)
Models: 3340 thru 3349, 3355, 3356
Ref.
Description
1.
Log Set -RDVOD/RNVOD
1a.
Right Rear Log RDNOD/RNVOD
1b.
Left Rear Log RDVOD/RNVOD
1c.
Right Log RDVOD/RNVOD
2.
Manifold Assembly
3.
Lava Rock - Burner
4.
Frame, Glass RDV40
5.
Glass, Gasket Med. Knit - RDV40
6.
Glass, GFP Firebox
7a.
Valve RN Honeywell VS8420E 2038
7b.
Valve RP Honeywell VS8420E 2020
8a.
Pilot Assembly 3/BVent RN 0.199.705
8b.
Pilot Assembly 3/BVent RP 0.199.704
8c.
Pilot Assembly 3Way N/DV RN 0.199.706 Serial #’s starting at #1457 (RNVODRN)
8d.
Pilot Assembly 3Way N/DV RP 0.199.703 Serial #’s starting at #1944 (RNVODRP)
9a.
Thermocouple Serial #’s up to #1456 (RNVODRN), #1943 (RNVODRP)
9b.
Thermocouple 24” Serial #’s starting at #1457 (RNVODRN), 1944 (RNVODRP)
10.
Electrode Ignitor w/cable SIT 24
11.
Pilot Top Convertible
12.
Thermopile 18” RS
13.
Nut Electrode SIT #0.974.144
14.
Tubing Pilot w/ Fitting 1/8 x 24”
15a.
Orifice Pilot #62 NG Top Convertible
15b.
Orifice Pilot #35 - LP Top Convertible
16.
Burner Housing Assembly
17.
Burner Decorative Grate
18a.
Switch, Vent Safety
Serial #’s up to #1456 (RNVODRN), #1943 (RNVODRP)
18b.
Switch, Spill - RNVOD
Serial #’s starting at #1457 (RNVODRN) #1944 (RNVODRP)
19.
Wiring Harness - FSDV32RN/JDV
20.
Switch, ON/OFF JDV
21.
Front II RDVOD
22.
Door, Left, RDVOD
23.
Door, Right, RDVOD
24.
Control Door, RDVOD
25.
Handle Package, Ceramic w/SCR
26a.
Orifice Hood, #57 Front - LP
26b.
Orifice Hood, #51 Front - NG
26c.
Orifice Hood, #54 Rear - LP
26d.
Orifice Hood, #40 Rear - NG
27.
Bracket, Right Log
20005039
10002582
30000874
Refer to Enamel Parts Chart Page 26
Refer to Enamel Parts Chart Page 26
Refer to Enamel Parts Chart Page 26
Refer to Enamel Parts Chart Page 26
0004342
20004587
30000449
20000130
20004263
20005259
RNVOD
20004184
20004185
20004186
20004187
20003739
57897
1409112
1203702
1601290
10001782
10001759
10002389
10002390
10002264
10002265
54912
53373
7531137
10001297
10002266
51827
7533113
57886
10001296
10002268
10002269
20003526
20003536
51866
20004409 25
Radiance Natural Vent Gas Heater
Radiance Natural Vent (RNVOD)
(continued)
Models: 3340 thru 3349, 3355, 3356
Ref.
Description RNVOD
28.
Bracket, Left Log
29.
Base Pan Inner Gasket
30.
Bracket, Back Log - RDVOD
31.
Grille, RVF
32.
Screen, RVF
33a.
Vent Switch Wire Assembly - RNV40
Serial #’s up to #1456 (RNVODRN), #1943 (RNVODRP)
20005258
20004286
20003577
Refer to Enamel Parts Chart Page 26
1601933
30000108
33b.
Spill Switch Wire Assembly - RNVOD
34.
35.
36.
37.
Serial #’s starting at #1457 (RNVODRN), #1944 (RNVODRP)
Damper Steel Handle/Screw
Latch, Front DR - RDV
Control Door Handle Assy
Interrupter Block Serial #’s starting at #1457 (RNVODRN), #1944 (RNVODRP)
20005700
5004265
30001249
10004442
30000069
38.
Draft Hood Final Assembly Serial #’s starting at #1457 (RNVODRN), #1944 (RNVODRP) 20005118
39.
Left End Refer to Enamel Parts Chart Page 26
40.
Right End
41.
Leg
Refer to Enamel Parts Chart Page 26
Refer to Enamel Parts Chart Page 26
42.
Top
43.
Inner Shroud Grommet
Refer to Enamel Parts Chart Page 26
20005860
Fuel Conversion Kits
Conversion Kit, NG to LP - RDVOD/RNVOD NG
Conversion Kit, LP to NG - RDVOD/RNVODRP
Kit #000-5010
Kit #000-5009
Shell Enamel Part Numbers
Model Color Top Left Right Front Left Right Control Top Leg
Number End End Door Door Door Grille (4)
3340, 3345 Classic 1301235 30001751 30001752 30001376 30001378 30001377 30001413 1301192 30001753
3341, 3346 New Red 2321235 30001771 30001770 30001416 30001418 30001417 30001419 1301192 30001772
3342, 3347 Sand 1321235 30001774 30001773 30001420 30001422 30001421 30001423 1301192 30001775
3343, 3348 Moonlight 2371235 30001777 30001776 30001424 30001426 30001425 30001427 1301192 30001778
3344, 3349 Green 2311235 30001780 30001779 30001428 30001430 30001429 30001431 1301192 30001781
Suede
3355, 3356 Brown 30002513 30002512 30002511 30002514 30002516 30002515 30002517 1301192 30002518
26 26 20004409
Radiance Natural Vent Gas Heater
Optional Accessories
Fan Kits
FK26 Fan
The FK26 fan kit helps distribute heated air from within the firebox out into the room. The fan is controlled by a snapstat that turns power on and off as the firebox temperature rises above and falls below a preset temperature. A rheostat provides for variable fan speeds.
Specifications
115 Volt / 60Hz / .75 amps
Maintenance
The fan itself does not require regular maintenance, however, periodic cleaning of the fan and the surrounding area is required.
Installation
Refer to Page 8 for installation instructions.
Remote Controls
The remote control allows you to turn the heater on or off from anywhere in the room. Refer to Page 23 for wiring diagrams.
Model
MRC1
MRC2
MRC3
IMT
Functions Controlled
ON/OFF
ON/OFF and Temperature
ON/OFF and Temperature control with a digital display and a programmable 24 hour clock
Wall mounted thermostat control
Screen Kit
An optional screen, R40SK, is available for use with the operable doors to allow the doors to be left in the open position.
Warming Shelf
Warming shelves add versatility to your stove; they can be used to keep foods warm at mealtime.
Model Color
1560
1565
1562
1566
1567
Classic Black
Red
Sand
Green
Moonlight Blue
1568 Suede Brown
The shelf installation is accomplished in three stages.
First attach the shelf loosely to the stove, leaving the screws loose enough to allow final adjustments. Then, position the shelf and adjust the brackets so the shelf fits correctly. Finally, tighten the screws.
Refer to the instructions included with each warming shelf for complete installation procedures.
Decorative Rings
7” brass or charcoal gray rings are available to add a decorative touch to the exposed stove pipe.
Model Description
4FSDRP/4 4” Polished Brass Rings (4)
4FSDRB/4 4” Black Rings (4)
Outside Air Adapter
An outside air adpater, #5076, may be added to the stove to bring fresh air directly from outside the building into the stove.
20004409 27
Radiance Natural Vent Gas Heater
28 28 20004409
Radiance Natural Vent Gas Heater
20004409 29
Radiance Natural Vent Gas Heater
LIMITED LIFETIME WARRANTY
PRODUCT COVERED BY THIS WARRANTY
All Vermont Castings gas stoves, gas inserts, and gas fireplaces, and all Majestic or Northern Flame brand gas fireplaces equipped with an Insta-Flame Ceramic Burner, or standard steel tube burner.
BASIC WARRANTY
CFM Specialty Home Products (hereinafter referred to collectively as the Company) warrants that your new Vermont Castings or Majestic
Gas Fireplace/Stove is free from manufacturing and material defects for a period of one year from the date of purchase, subject to the following conditions and limitations.
EXTENDED LIFETIME WARRANTY
The heat exchanger, where applicable, and combustion chamber of every Vermont Castings or Majestic gas product is warranted for life against through wall perforation. All appliances equipped with an
Insta-Flame Ceramic Burner have limited lifetime coverage on the ceramic burner plaque. Warrantees are made to the original owner subject to proof of purchase and the conditions and limitations listed on this Warranty Document
COMPONENT WARRANTY
CAST IRON: All external and internal cast iron parts are warranted for a period of three years.
Note: On porcelain enamel finished external parts and accessories
The Company offers no Warranty on chipping of enamel surfaces.
Inspect all product prior to accepting it for any damage to the enamel.
The salt air environment of coastal areas or a high humidity environment can be corrosive to the porcelain enamel finish. These conditions can cause rusting of the cast iron beneath the porcelain enamel finish, which will cause the finish to flake off.
Dye lot variations with replacement parts and/or accessories can occur and are not covered by warranty.
GLASS DOORS: Glass doors are covered for a period of one year.
Glass doors are not warranted for breakage due to misuse or accident. Glass doors are not covered for discoloration or burned in stains due to environmental issues, or improper cleaning and maintenance.
BRASS PLATED PARTS AND ACCESSORIES: Brass parts should be cleaned with Lemon oil only. Brass cleaners cannot be used. Mortar mix and masonry cleaners may corrode the brass finish. The
Company will not be responsible for, nor will it warrant any brass parts which are damaged by external chemicals or down draft conditions.
GAS VALVES: Gas valves are covered for a period of one year
ELECTRONIC AND MECHANICAL COMPONENTS: Electronic and mechanical components of the burner assembly are covered for one year. All steel tube burners are warranted for one year.
ACCESSORIES: Unless otherwise noted all components and CFM
Specialty Home Products company supplied accessories are covered for a period of one year.
CONDITIONS AND LIMITATIONS
• This new Vermont Castings or Majestic product must be installed by a competent, authorized, service contractor. A licensed technician, as prescribed by the local jurisdiction must perform any installation/ service work. It must be installed and operated at all times in accordance with the Installation and Operating instructions furnished with the product. Any alteration, willful abuse, accident, or misuse of the product shall nullify this warranty.
• This warranty is non-transferable, and is made to the original owner, provided that the purchase was made through an authorized supplier of the Company.
• The customer must pay for any Authorized Dealer in-home travel fees or service charges for in-home repair work. It is the dealers option whether the repair work will be done in the customer’s home or in the dealer’s shop.
• If upon inspection, the damage is found to be the fault of the manufacturer, repairs will be authorized at no charge to the customer parts and/or labor.
• Any part and/or component replaced under the provisions of this warranty is covered for six months or the remainder of the original warranty, whichever is longest.
• This warranty is limited to the repair of or replacement of part(s) found to be defective in material or workmanship, provided that such part(s) have been subjected to normal conditions of use and service, after said defect is confirmed by the Company’s inspection.
• The company may, at its discretion, fully discharge all obligations with respect to this warranty by refunding the wholesale price of the defective part(s)
• Any installation, labor, construction, transportation, or other related costs/expenses arising from defective part(s), repair, replacement, or otherwise of same, will not be covered by this warranty, nor shall the
Company assume responsibility for same. Further, the Company will not be responsible for any incidental, indirect, or consequential damages except as provided by law.
• SOME STATES DO NOT ALLOW FOR THE EXCLUSION OR
LIMITATIONS OF INCIDENTAL AND CONSEQUENTIAL DAMAGES
OR LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS,
SO THE ABOVE LIMITATIONS MAY NOT APPLY TO YOUR
CIRCUMSTANCES. THIS WARRANTY GIVES YOU SPECIFIC
RIGHTS AND YOU MAY HAVE OTHER RIGHTS WHICH VARY
FROM STATE TO STATE.
• All other warranties-expressed or implied- with respect to the product, its components and accessories, or any obligations/liabilities on the part of the Company are hereby expressly excluded.
• The Company neither assumes, nor authorizes any third party to assume on its behalf, any other liabilities with respect to the sale of this Vermont Castings or Majestic product
• The warranties as outlined within this document do not apply to chimney components or other non CFM Specialty Home Products accessories used in conjunction with the installation of this product..
• Damage to the unit while in transit is not covered by this warranty but is subject to claim against the common carrier. Contact the dealer from whom you purchased your fireplace/stove (do not operate the appliance as this might negate the ability to process the claim with the carrier).
• The Company will not be responsible for: a) Down drafts or spillage caused by environmental conditions such as near-by trees, buildings, roof tops, hills, or mountains.
b) Inadequate ventilation or negative air pressure caused by mechanical systems such as furnaces, fans, clothes dryers, etc.
• This warranty is void if: a) The fireplace has been operated in atmospheres contaminated by chlorine, fluorine, or other damaging chemicals.
b) The fireplace has been subjected to prolonged periods of dampness or condensation c) Any damages to the fireplace, combustion chamber, heat exchanger or other components due to water, or weather damage, which is the result of but not limited to, improper chimney/venting installation.
d) Any alteration, willful abuse, accident, or misuse of the product has occurred.
IF WARRANTY SERVICE IS NEEDED…
1) Contact your supplier. Make sure you have your warranty, your sales receipt, and the model/serial number of your
CFM Specialty Home Products product.
2) DO NOT ATTEMPT TO DO ANY SERVICE WORK
YOURSELF.
30 30 20004409
PRODUIT COUVERT PAR LA PRÉSENTE GARANTIE
L’ensemble des cuisinières à gaz, des poêles encastrables et des foyers à gaz Vermont Castings, ainsi que l’ensemble des foyers à gaz de marque Majestic ou Northern Flame équipés d’un brûleur en céramique Insta-Flame ou d’un brûleur en acier standard.
GARANTIE DE BASE
La société CFM Specialty Products (ci-après la « Société ») garantit votre nouveau poêle/foyer au gaz Vermont Castings ou Majestic contre tous défauts de fabrication et de matières premières pour une période d’un an à compter de la date d’achat, sous réserve des conditions et limitations suivantes.
GARANTIE À VIE PROLONGÉE
L’échangeur de chaleur, s’il y a lieu, ainsi que la chambre à combustion de tout produit à gaz de la société Vermont Castings ou Majestic sont garantis pour la vie contre la perforation des parois. Tous les produits équipés d’un brûleur en céramique Insta-Flame comprennent une garantie à vie limitée de la plaque du brûleur en céramique.
Les garanties sont accordées à l’acheteur d’origine, le tout sujet à une preuve d’achat et aux conditions et limitations suivantes :
GARANTIE DES COMPOSANTS
FONTE : Toutes les pièces en fonte externes et internes sont garanties pour une période de trois ans.
Nota : Dans le cas des pièces et accessoires externes au fini en émail de porcelaine, la Société n’offre aucune garantie quant à l’écaillage des surfaces en émail. Avant d’accepter un produit, inspectez-le afin de vous assurer que les surfaces en émail ne sont pas endommagées.
L’atmosphère saline des zones côtières ou les environnements à forte humidité peuvent provoquer la corrosion du fini en émail de porcelaine. Ces conditions peuvent également faire rouiller la fonte sous le fini en émail de porcelaine, provoquant ainsi l’écaillement de la couche de fini.
Dans le cas des pièces et (ou) des accessoires de remplacement, les variations de lots de teinture sont possibles, mais elles ne sont pas couvertes par la garantie.
PORTES EN VERRE : Les portes en verre sont couvertes pour une période d’un an. Les portes en verre ne sont pas garanties contre le bris causé par un mauvais usage ou un accident. Les portes en verre ne sont pas couvertes contre la décoloration ni contre les taches imprégnées attribuables à des conditions environnementales ou à un nettoyage et un entretien inadéquats.
PIÈCES ET ACCESSOIRES PLAQUÉS EN LAITON : Les pièces en laiton ne doivent être nettoyées qu’avec de l’essence de citron. Les nettoyants pour le laiton ne doivent pas être utilisés, et les agents nettoyants pour le mortier et la maçonnerie peuvent provoquer la corrosion du fini laiton. La Société ne pourra être tenue responsable des dommages à toute pièce en laiton occasionnés par des conditions chimiques externes ou le refoulement, et elle n’offre aucune garantie à cet égard.
SOUPAPES À GAZ : Les soupapes à gaz sont couvertes pour une période d’un an.
COMPOSANTS ÉLECTRONIQUES ET MÉCANIQUES : Les composants électroniques et mécaniques du brûleur sont couverts pendant un an. Tous les brûleurs en acier sont garantis pendant un an.
ACCESSOIRES : À moins d’indication contraire, tous les composants et accessoires fournis par CFM Specialty Home Products sont couverts pendant une période d’un an.
CONDITIONS ET LIMITATIONS
• Ce nouveau produit Vermont Castings ou Majestic doit être installé par un entrepreneur de service autorisé et compétent. L’installation/le service doivent être assurés par un technicien breveté, conformément
à la juridiction locale. Le produit doit être installé et utilisé en tout temps selon les instructions d’installation et de fonctionnement fournies avec le produit. Toute altération ou tout abus volontaire, accident ou mauvais usage du produit annulera cette garantie.
• Cette garantie n’est pas transférable et est offerte à l’acheteur d’origine, à condition que l’achat ait été effectué par l’entremise d’un détaillant autorisé de la Société.
• Le client doit assumer les frais de déplacement à domicile de tout détaillant autorisé ou les frais de service relatifs à toute réparation effectuée à domicile. Le détaillant peut à son choix effectuer les réparations chez le client ou à son atelier.
• Si, lors de l’inspection, on constate que les dommages sont la faute du
20004409 fabricant, les réparations, les pièces et la main-d’œuvre seront autorisées sans frais pour le client.
• Toute pièce et (ou) tout composant remplacé en vertu des dispositions de la présente garantie est couvert pour une période de six mois ou jusqu’à l’expiration de la garantie originale, selon la dernière des
éventualités à survenir.
• Cette garantie est limitée à la réparation ou au remplacement de toute pièce trouvée défectueuse en matières premières ou main-d’oeuvre,
à condition que ladite pièce ait été sujette aux conditions normales d’usage et de service, après que ledit défaut a été confirmé par une inspection par la Société.
• La Société peut, à sa discrétion, se décharger entièrement de toutes obligations se rapportant à cette garantie en remboursant le prix de gros de toute pièce défectueuse.
• Tous les frais/dépenses d’installation, de main-d’oeuvre, de construction, de transport ou autres causés par toute pièce défectueuse, une réparation, un remplacement ou autre, ne seront pas couverts en vertu de la présente garantie, et la Société n’assume aucune responsabilité pour ceux-ci. De plus, la Société ne pourra être tenue responsable de tous dommages fortuits ou indirects, sauf là où prévu par la loi.
• CERTAINS PROVINCES NE PERMETTENT PAS L’EXCLUSION OU
LES LIMITATIONS RELATIVES AUX DOMMAGES CONSÉCUTIFS
OU INDIRECTS QUANT À LA DURÉE DE TOUTE GARANTIE IMPLI-
CITE, SI BIEN QU’IL EST POSSIBLE QUE LES LIMITATIONS
CI-DESSUS NE S’APPLIQUENT PAS DANS VOTRE CAS. LA PRÉ-
SENTE GARANTIE VOUS DONNE DES DROITS SPÉCIFIQUES, ET
IL EST POSSIBLE QUE VOUS AYEZ D’AUTRES DROITS QUI
PEUVENT VARIER D’UN ÉTAT À L’AUTRE.
• Toute autre garantie, expresse ou implicite, en ce qui a trait au produit et ses composants et accessoires, ou toute obligation/responsabilité de la part de la Société sont expressément exclues en vertu des présentes.
• La Société n’assume et n’autorise personne à assumer, en son nom, toute responsabilité en ce qui a trait à la vente de ce produit Vermont
Castings ou Majestic.
• Les garanties, telles qu’elles sont décrites dans le présent document, ne s’appliquent pas aux composants de cheminée ni à d’autres accessoires CFM Specialty Home Products utilisés conjointement avec l’installation de ce produit.
• Les dommages causés à l’unité tandis qu’elle est en transit ne sont pas couverts par la présente garantie, mais pourront être l’objet d’une réclamation contre le transporteur général. Communiquez avec le détaillant chez qui vous avez acheté votre foyer/poêle (n’utilisez pas l’appareil étant donné que cela pourrait annuler toute réclamation contre le transporteur).
• La Société n’engagera aucune responsabilité quant : a) au refoulement de cheminée ou débordement causé par les conditions environnementales (arbres, édifices, toits, coteaux ou montagnes adjacents); b) à une ventilation inadéquate ou une pression d’air négative causée par des systèmes mécaniques comme les fournaises, les ventilateurs, les sécheuses, etc.
• Cette garantie est nulle si : a) le foyer a été utilisé dans une atmosphère contaminée par du chlore, du fluor ou tout autre produit chimique; b) le foyer est assujetti à de longues périodes d’humidité ou de condensation; c) des dommages sont causés au foyer, à la chambre de combustion,
à l’échangeur de chaleur ou aux autres composants par de l’eau ou par la température qui est le résultat mais sans y être limité, d’une mauvaise installation de cheminée/ventilation; d) toute altération ainsi que tout abus volontaire, accident ou mauvais usage du produit annule la présente garantie.
SI UN SERVICE SOUS GARANTIE EST REQUIS…
1) Communiquez avec votre détaillant. Assurez-vous que vous avez votre garantie, votre reçu de caisse ainsi que le numéro de modèle/ série de votre produit CFM Specialty Home Products.
2) NE TENTEZ PAS D’EFFECTUER DES RÉPARATIONS VOUS-
MÊME.
31
CFM Specialty Home Products
410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777 www.majesticproducts.com • www.vermontcastings.com
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 4 Stove Dimensions
- 5 Clearance Requirements
- 5 Alcove Minimum Dimensions
- 5 Hearth Requirements
- 6 Gas Specifications
- 6 Gas Inlet and Manifold Pressures
- 6 High Elevations
- 6 Venting Requirements and Options
- 6 Vent Layout and Height Requirements
- 7 Passing Through a Combustible Wall or Ceiling
- 7 Venting Requirements
- 8 Tools Required
- 8 Parts Bag Contents
- 8 Unpack and Assemble Legs
- 12 Venting System Assembly
- 13 Connect the Gas Supply Line
- 13 Burner Information
- 13 Install ON/OFF Switch
- 14 Thermostat Connection
- 14 Install the Mesh and Grille
- 14 Install Rear Bracket and Log Set
- 16 Operable Doors
- 16 Your First Fire
- 16 Pilot and Burner Inspection
- 16 Flame & Temperature Adjustment
- 16 Flame Characteristics
- 17 Lighting and Operating Instructions
- 18 Troubleshooting
- 19 Fuel Conversion Instructions
- 21 Annual System Inspection
- 21 Logset and Burner Cleaning and Inspection
- 21 Care of Cast Iron
- 21 Cleaning the Glass
- 21 Glass Replacement
- 22 Gasket Replacement
- 22 Inspect the Vent System Annually
- 22 Check the Gas Flame Regularly
- 23 Wiring Diagrams
- 24 Replacement Parts
- 27 Optional Accessories
- 30 Warranty