4、Connection terminals
C3-400 Installation Instructions and Connection Guide
Vision:1. 0 .1
Date:O c t.2010
1.Cautions
Notes:
1)Meaning of LED indicators:
2)Recommended use of wires:
LINK indicator(green): always(green) indicates TCP/IP
communication is proper;
A Use 2-conducotor power cord
ACT indicator(yellow):its flashing indicates data is in transmitting
through TCP/IP communication.
B Use 6-conductor wire between wiegand reader and control panal
(RVVP 6*0.5mm) (To choose the proper cord according to the
interface you connect, such as 6,8,10 cord.)
TX indicator(yellow):its flashing indicates it is sending data through
RS485 communication.
C Use 4-conducotor lock power cord (RVV 4*0.75mm)
RX indicator(green):its flashing indicates it is receiving data through
RS485 communication.
Please note the following cautions.Mis-operation may lead to personal injury or equipment failure:
1) Do not energize the system before installation is complete; never carry out installation activities when
the system is energized.
2) All peripheral devices must be grounded.
3) It is preferred that all wires run through PVC or galvanized pipes.
Auxiliary output indicator(green):always(green) indicates it is in use.
Lock indicator(green):always(green) indicates lock is open.
D Use 2-conducotor switch power cord(RVV 2*0.5mm)
3)The auxiliary input may be connnected to infrared body detectors,
alam switches,etc.
4)The auxiliary output may be connected to door bells,alarms,etc.
POWER indicator(red): always(red) indicates control panel is power
on.
RUN indicator(green):its flashing indicates the system works normally.
CARD indicator(yellow):its flashing indicates card is punched on reader.
4) It is strongly recommended that the length of exposed part of any connection cable should not be longer
LINK
SD Card
avoid short-circuit or communication failure.
LAN
Ethernet interface
IN
GND
lock.
Advanced Access Control
TX
RX
D
Auxiliary input1
D
Auxiliary input2
D
Auxiliary input3
D
Auxiliary input4
+12V
GND
485485+
IN
BUTTON1
PC
RS485 interface
485+
485GND
EXT
constantly and the RUN indicator(green) flashes.
IN
GND
AUX4
5 6 7 8
Connect the system to the power supply.If the system works properly,the POWER indicator(red) is lit
GND
AUX3
ON
1 2 3 4
Dip switch
Description of normal working state:
IN
ACT
AUX2
6) It is recommended to use the power supply in case for control panel, and external power supply for each
AUX1
IN
GND
5) It is recommended that card readers and buttons should be installed at height of 1.4m-1.5m above ground.
{
{
{
{
than 4 mm. Professional clamping tools may be used to avoid unintentional contact of exposed wires to
TX
RX
+12V
GND
RUN CARD
B
2# Door
wiegand reader
D
3# Door Button
B
3# Door
wiegand reader
D
{
POWER
+12V
D
2# Door Button
{
WD1
WD0
GND
B
1# Door
wiegand reader
{
Power of control panel
BEEP
GLED
READER4
Fixed case
A
V+
V-
IN
GND
BUTTON4
1
Get through the thread hole
2
LOCK POWER
A
Power of lock
SEN
GND
NO
COM
NC
1
Door4
LOCK4
C
BEEP
GLED
WD1
WD0
GND
+12V
READER3
Thread hole
1
C
Door3
SEN
GND
NO
COM
NC
IN
GND
BUTTON3
3.Get through the thread hole
GND
+12V
1
C
Door2
SEN
GND
NO
COM
NC
BEEP
GLED
WD1
WD0
READER2
Appearance of case
LOCK3
{
{
{
{
Door1
SEN
GND
NO
COM
NC
IN
GND
1
C
Thread hole
NO
COM
NC
1# Door Button
{
{
{
{
D
Auxiliary output4
BUTTON2
Heat
dissipation
hole
BEEP
GLED
WD1
WD0
GND
+12V
D
{
Auxiliary output3
GND
READER1
D
LOCK2
Key hole
NO
COM
NC
LOCK1
Auxiliary output2
NO
COM
NC
AUXOUT4
D
AUXOUT3
Backup battery Power supply Control panel
NO
COM
NC
AUXOUT2
{
{
{
{
AUXOUT1
2.Components
D
Auxiliary output1
4# Door Button
B
4# Door
wiegand reader
5.RS485 address setting, Restore factory setting, Terminal resistance setting
7.Equipment communication
Set RS485 address through DIP switch:
1) Place 1-6 on DIP switch are for setting the number of control panel when communicating through
RS485, it is adopted for binary coding, and little endian, the address represented by place 1-6 are
shown as figurue(5-1).
2) Before setting the address, please keep the system is power off, Jump place 1-6 to desired status,
and the address number shall not be the same as another one in the network. For example: to set the
device number as 39 (39=1+2+4+32), the corresponding RS485 code is 111001, then Jump place 1,
ON
2,3 and 6 at “ON” status.
1
2
3
4
5
6
7
The background PC software is able to communicate with the system according to two protocols(RS485 and TCP/IP) for data
exchange and remote management. The communication cable should be away from high-voltage lines as far as possible. Do
not keep the communication cable in parallel with power cords or bind them together.
1.TCP/IP Communication
PC
8
Switch
3) Place 7 is for restoring factory default settings, Jump it for three times within 10 seconds and restart
the system, then all information in RAM of control panel will be cleared and the system restores factory
default settings.
1# control panel
LINK
LINK
SD Card
BUTTON1
READER1
BUTTON2
READER2
BUTTON3
READER3
BUTTON4
1
READER4
+12V
+12V
RUN CARD
GND
RUN CARD
GND
BUTTON4
READER4
485
LOCK POWER
Converter
serial line
485+
485+
485+
485-
485-
485-
GND
GND
GND
PC
LINK
SD Card
LAN
IN
READER1
BUTTON2
BUTTON3
BEEP
GLED
WD1
WD0
GND
+12V
READER3
IN
GND
BUTTON4
POWER
DIP switch
READER4
LOCK POWER
WD1
WD0
GND
7 8
READER2
LOCK4
V+
V-
IN
GND
BEEP
GLED
1
LOCK3
SEN
GND
NO
COM
NC
GND
+12V
1
LOCK2
SEN
GND
NO
COM
NC
BEEP
GLED
WD1
WD0
1
LOCK1
SEN
GND
NO
COM
NC
IN
GND
1
NO
COM
NC
SEN
GND
NO
COM
NC
GND
BEEP
GLED
WD1
WD0
GND
+12V
ON
GND
485485+
BUTTON1
NO
COM
NC
AUXOUT4
READER4
+12V
RUN CARD
NO
COM
NC
AUXOUT3
BUTTON4
POWER
AUXOUT2
READER3
LOCK POWER
WD1
WD0
GND
AUXOUT1
BUTTON3
IN
GND
NO
COM
NC
1 2 3 4 5 6
+12V
EXT
TX
RX
IN
GND
AUX4
PC
485+
485GND
GND
AUX3
5 6 7 8
Advanced Access Control
AUX2
IN
ACT
AUX1
ON
READER2
BEEP
GLED
WD1
WD0
GND
+12V
+12V
GND
BUTTON2
IN
GND
BEEP
GLED
1
LOCK4
V+
V-
GND
+12V
1
LOCK3
SEN
GND
NO
COM
NC
BEEP
GLED
WD1
WD0
READER1
LOCK2
SEN
GND
NO
COM
NC
IN
GND
BUTTON1
LOCK1
SEN
GND
NO
COM
NC
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
1
NO
COM
NC
SEN
GND
NO
COM
NC
IN
GND
1 2 3 4
EXT
GND
485485+
IN
GND
LAN
+12V
SD Card
TX
RX
1
AUXOUT4
READER4
RUN CARD
IN
GND
AUX4
NO
COM
NC
+12V
GND
AUX3
NO
COM
NC
AUXOUT3
BUTTON4
+12V
NO
COM
NC
AUXOUT2
READER3
WD1
WD0
GND
POWER
BUTTON3
1
BEEP
GLED
TX
RX
GND
TX
RX
AUXOUT1
READER2
IN
GND
485+
485GND
LINK
AUX2
Advanced Access Control
PC
BUTTON2
1
BEEP
GLED
WD1
WD0
GND
+12V
ACT
5 6 7 8
READER1
IN
GND
IN
AUX1
ON
1 2 3 4
BUTTON1
BEEP
GLED
WD1
WD0
GND
+12V
1
LOCK POWER
V+
V-
GND
1
LOCK4
AUX3
AUX4
+12V
+12V
GND
RUN CARD
1# control panel
2# control panel
8# control panel
EXT
GND
485485+
Notes:
READER2
BEEP
GLED
WD1
WD0
BUTTON2
IN
GND
READER1
BEEP
GLED
WD1
WD0
GND
+12V
BUTTON1
IN
GND
+12V
BEEP
GLED
WD1
WD0
GND
+12V
READER3
IN
GND
BUTTON4
1
WD1
WD0
GND
LED
1
2
3
4
5
Jumper
terminal
READER4
BEEP
GLED
POWER
BUTTON3
IN
GND
1
LOCK POWER
V+
V-
LOCK3
GND
IN
GND
GND
1
SEN
GND
NO
COM
NC
SEN
GND
NO
COM
NC
IN
IN
GND
AUX2
TX
RX
1
SEN
GND
NO
COM
NC
LOCK4
+
+
-
SEN
GND
NO
COM
NC
LOCK3
Lock power
input
SEN
GND
NO
COM
NC
LOCK2
FR107
NO
COM
NC
LOCK1
NC
NO
COM
NC
AUXOUT4
COM
Diode
NO
COM
NC
AUXOUT3
NO
NO
COM
NC
SEN
GND
NO
COM
NC
IN
GND
+12V
TX
RX
AUXOUT2
GND
485+
485GND
AUXOUT1
SEN
Advanced Access Control
PC
-
+
IN
ACT
5 6 7 8
Diode
ON
1 2 3 4
Enlarged diagram
of lock ports
SEN
GND
NO
COM
NC
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
AUX1
LAN
IN
GND
NO Lock
SEN
GND
NO
COM
NC
LOCK2
SD Card
IN
GND
FR107
NO
COM
NC
LOCK1
LINK
NO
COM
NC
AUXOUT4
the polarities.
NO
COM
NC
AUXOUT3
diode (equipped in the package) to prevent the self-inductance EMF affecting the system, do not reverse
NO
COM
NC
AUXOUT2
3) When the Electrical Lock is connected to the Access Control System, you need to parallel one FR107
GND
485485+
TX
RX
AUXOUT1
factory default setting is dry mode. For setting “dry mode” and “wet mode”, please refer to <<C3-100/
200/400 access control panel installation instructions>>.
TX
RX
+12V
EXT
PC
485+
485GND
SD Card
LAN
Advanced Access Control
AUX4
5 6 7 8
IN
GND
LINK
AUX3
ON
1 2 3 4
connecting “V+ V-” Input interfaces to supply power for locks, please shorten 2-3 and 4-5. Equipment
IN
GND
AUX2
IN
ACT
AUX1
IN
GND
2) Control panel supports “dry mode” and “wet mode” by setting the jumper, it is “wet mode” when
-
+
IN
GND
WD1
WD0
GND
POWER
RUN CARD
GND
-
BEEP
GLED
WD1
WD0
GND
+12V
485+
485GND
power is off, and closed when power is on, so COM and NC” interfaces should be used.
LOCK
IN
GND
BEEP
GLED
V+
V-
+12V
closed when power is off, so “COM and NO” interfaces should be used; For NC lock, it is open when
-
EXT
GND
+12V
1
LOCK POWER
+12V
BEEP
GLED
WD1
WD0
1
SEN
GND
NO
COM
NC
IN
GND
1) Control panel provides lock control output interfaces. For NO lock ,it is open when power is on, and
LOCK
IN
GND
1
SEN
GND
NO
COM
NC
LOCK4
READER4
SEN
GND
NO
COM
NC
LOCK3
BUTTON4
SEN
GND
NO
COM
NC
LOCK2
READER3
NO
COM
NC
LOCK1
BUTTON3
READER3
IN
GND
6.Connection of lock
+
GND
485485+
BEEP
GLED
WD1
WD0
GND
+12V
+12V
GND
AUX4
NO
COM
NC
AUXOUT4
READER2
+12V
POWER
NO
COM
NC
AUXOUT3
BUTTON2
V+
V-
NO
COM
NC
AUXOUT2
READER1
WD1
WD0
GND
AUXOUT1
BUTTON1
BEEP
GLED
AUX3
PC
EXT
IN
GND
AUX2
5 6 7 8
AUX4
BEEP
GLED
WD1
WD0
GND
+12V
TX
RX
AUX1
ON
AUX3
1 2 3 4
AUX2
IN
GND
485+
485GND
+12V
TX
RX
GND
+12V
1
LOCK POWER
RUN CARD
BEEP
GLED
WD1
WD0
1
LOCK4
SEN
GND
NO
COM
NC
IN
GND
1
LOCK3
SEN
GND
NO
COM
NC
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
1
SEN
GND
NO
COM
NC
+12V
+12V
GND
SEN
GND
NO
COM
NC
LOCK2
READER4
POWER
NO
COM
NC
LOCK1
BUTTON4
1
V+
V-
NO
COM
NC
AUXOUT4
IN
GND
WD1
WD0
GND
AUXOUT3
READER3
1
BEEP
GLED
WD1
WD0
GND
+12V
BEEP
GLED
NO
COM
NC
BUTTON3
IN
GND
NO
COM
NC
AUXOUT2
READER2
GND
+12V
AUXOUT1
BUTTON2
BEEP
GLED
WD1
WD0
READER1
IN
GND
BUTTON1
IN
GND
BEEP
GLED
WD1
WD0
GND
+12V
1
BUTTON3
BEEP
GLED
WD1
WD0
GND
+12V
WD1
WD0
GND
POWER
GND
485485+
TX
RX
1
LOCK POWER
READER2
1
LOCK4
IN
GND
BEEP
GLED
V+
V-
SEN
GND
NO
COM
NC
+12V
TX
RX
Advanced Access Control
GND
IN
GND
2.RS485 Communication
GND
+12V
1
LOCK3
SEN
GND
NO
COM
NC
SEN
GND
NO
COM
NC
BEEP
GLED
WD1
WD0
Advanced Access Control
485+
485GND
IN
ACT
BUTTON2
LOCK2
SEN
GND
NO
COM
NC
IN
GND
1
SEN
GND
NO
COM
NC
1
NO
COM
NC
LOCK1
figure( 5 -1)
NO
COM
NC
AUXOUT4
Restore
factory setting.
BEEP
GLED
WD1
WD0
GND
+12V
READER1
AUXOUT3
RS485
terminal
resistance.
GND
SEN
GND
NO
COM
NC
LOCK4
AUXOUT2
NO
COM
NC
IN
BUTTON1
NO
COM
NC
SEN
GND
NO
COM
NC
LOCK3
TX
RX
TX
RX
AUXOUT1
32
16
8
4
2
1
8
SEN
GND
NO
COM
NC
LOCK2
7
GND
485485+
NO
COM
NC
LOCK1
6
+12V
EXT
5
IN
GND
AUX4
4
PC
3
AUX3
5 6 7 8
2
Advanced Access Control
485+
485GND
AUX2
ON
1 2 3 4
1
IN
GND
NO
COM
NC
AUXOUT4
LAN
IN
GND
ACT
AUX1
IN
GND
NO
COM
NC
AUXOUT3
SD Card
AUXOUT2
LINK
AUXOUT1
ON
IN
GND
PC
TX
RX
Diagram of places of DIP switch.
GND
5 6 7 8
GND
485485+
ON
TX
RX
EXT
PC
485+
485GND
+12V
IN
ACT
IN
GND
GND
1 2 3 4
Advanced Access Control
AUX4
5 6 7 8
IN
GND
IN
GND
LAN
GND
IN
AUX3
ON
1 2 3 4
IN
ACT
SD Card
SD Card
IN
GND
AUX2
GND
LINK
AUX1
LAN
IN
LAN
IN
GND
NO
COM
NC
n# control panel
2# control panel
AUX1
4) Place 8 is for setting terminal resistance when communicating through RS485. Jump it at “ON” status,
then it is equivalent to have a terminal resistance of 120 ohm between 485+ and 485-.
+12V
1)Internationally accepted RVSP(shielded twisted-pair) wires should be used for communication to effectively avoid interference.
RS485 communication wires should be connected by means of bus cascade connection.
2)Considering stability of communication, it is recommended the length of RS485 bus is less than 600m
3)One RS485 BUS may hold 63 units of control panel, but it is not recommended to connect with more than 32 units.
access control panels.
4)When the bus is longer than 300m, to enhance the stability of communication, it is necessary to keep place 8 of DIP
+12V
GND
RUN CARD
NC Lock
switches of the first and the last control panel at “ON” status.
As shown in the figure above, place 8 of the DIP switches of units 1# and 8# is placed at "ON
“Wet mode” wiring diagram of lock connecting with external power supply.
ON
1 2 3 4 5 6 7 8
" status.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising