MORTARA Ambulo 2400 Specs

MORTARA Ambulo 2400 Specs
Ambulo 2400
AMBULATORY BLOOD PRESSURE MONITORING SYSTEM
PRODUCT FEATURES
• 24-hour Ambulatory Solution
24-hour ambulatory blood pressure monitoring system
offering state-of-the-art innovation, accuracy, and
reliability.
• Highly Accurate
Validated to stringent clinical accuracy standards including
the British Hypertension Society, AAMI SP-10, and the
global ISO standard.
• Trusted Technology
Patented oscillometric technology, along with powerful
Microsoft® Windows®-based software, enables
comprehensive setup, collection, analysis, and
documentation of blood pressure data.
• Actigraphy Option
Automatic determination of asleep/awake cycles based
on patented technology reduces reliance on diaries,
and enables synchronization of before/after studies in
clinical review.
• Full Disclosure
Detailed reporting of blood pressure measurements over
the circadian rhythm, as well as all events and errors.
• Impressively Comfortable
A compact, lightweight design, combined with gentle
linear bleed technology, enables patients to go about their
daily activities with comfort and minimal interruption.
ABPM
• Easy and Convenient
Quick, simple connection benefits clinicians and patients.
Quiet and smooth operation increases patient compliance
and aids in producing accurate measurement results.
• Safe and Secure Data Transfer
Mortara Web Upload enables secure and efficient upload
of ambulatory blood pressure data from virtually any
location. Healthcare and clinical research professionals
alike can share and expedite studies using this convenient
data transfer tool.
AMB U L O ™ 2 4 0 0 BP MONITOR ING S YS TE M
F E AT U R E
S P E C I F I C AT I O N *
DIME NS IONS
4.7 x 2 .7 x 1.2 " (119 x 68 x 32 mm)
WE IGHT
9.0 oz (2 53 g) (with batteries)
ME AS UR E ME NT P R INCIP L E
Patented oscillometric technique with linear deflation.
ME AS UR E ME NT R ANGE S
Systolic: 60 to 280 mmHg
Diastolic: 30 to 160 mmHg
Pulse R ate: 30 to 180 bpm
Blood Pressure: +_3 mmHg mean difference
+_8 mmHg standard deviation
+_3 bpm
Pulse R ate:
According to ANS I/AAMI S P-10 :200 2 & BHS
(Grade A/A) and ISO 810 60 -2 :2009
ME AS UR E ME NT ACCUR ACY
ME AS UR E ME NT INT E R VAL S
Optional configuration support for Phase I clinical trials
involving PK /PD dosing using discrete measurement
time points based on protocol requirements.
Measurements taken based on a sequence of time
points until completed.
Distributed by:
1-800-361-6991
www.mortara.com
Four adjustable intervals during 24 -hour periods, each
configurable to 0 , 5 , 10 , 15 , 20 , 2 5 , 30 , 4 5 , 60 , 75 ,
90 , 10 5 , or 120 - minute measurements. Optional
randomization factor up to 75 % within intervals.
Supports measurement over extended periods of time,
typically 24 hours, and up to 7 days.
IS O 134 8 5 CE R TIFIE D
AVAIL AB L E CUFFS
Regular, large and small adult cuffs included.
EasyWear™ cuff optional.
ACT IGR AP HY OP T ION
Recording of 3-axis of motion via accelerometer for
display and categorization of awake/asleep cycles via
application software.
ME MOR Y
S olid-state Flash technology. Sufficient for 2 ,700 blood
pressure measurements and 7 days of continuous actigraphy.
P C INT E R FACE
USB
B AT T E R Y P OWE R R E QUIR E ME NT S 2 x 1.2 V NiMH rechargeable batteries; 2 .4 V DC ;
Maximum current: 610 mA. Sufficient for approximately
300 measurements using regular adult cuff.
WAR R AN T Y + S E R VIC E
S OF T WAR E
Hypertension Diagnostics Suite requires PC running
Microsoft Windows XP SP2 , Windows Vista, or Windows 7
with a minimum graphics resolution of 10 24 x 768.
MAXIMUM NOIS E L E VE L
4 6 dBA during inflation; not measurable above ambient
level during deflation
*Specifications subject to change without notice.
Ambulo™ is a trademark of Mortara Instrument, Inc.
Microsoft® and Windows ® are registered trademarks of Microsoft Corporation in the United S tates and/or other countries.
R ef: 9513-182-01-E NG R ev 4