API Driver Manual of ACM120S
ACR120S
Contactless
Reader/Writer
Application Programming Interface
info@acs.com.hk
Subject to change without prior notice
www.acs.com.hk
Table of Contents
1.0.
Introduction ............................................................................................................... 3
2.0.
ACR120 ...................................................................................................................... 4
2.1.
2.2.
2.3.
Overview ................................................................................................................................4
Communication Speed ..........................................................................................................4
ACR120 API ..........................................................................................................................4
2.3.1.
Interface Function Prototypes .......................................................................................4
2.3.1.1. ACR120_Open............................................................................................................. 4
2.3.1.2. ACR120_Close ............................................................................................................ 5
2.3.1.3. ACR120_Reset ............................................................................................................ 5
2.3.1.4. ACR120_Select ........................................................................................................... 6
2.3.1.5. ACR120_Login............................................................................................................. 7
2.3.1.6. ACR120_Read............................................................................................................. 9
2.3.1.7. ACR120_ReadValue ................................................................................................. 12
2.3.1.8. ACR120_ReadEEPROM ........................................................................................... 13
2.3.1.9. ACR120_ReadLowLevelRegister .............................................................................. 15
2.3.1.10. ACR120_Write ......................................................................................................... 15
2.3.1.11. ACR120_WriteValue................................................................................................ 17
2.3.1.12. ACR120_WriteEEPROM ......................................................................................... 19
2.3.1.13. ACR120_WriteLowLevelRegister ............................................................................ 20
2.3.1.14. ACR120_WriteMasterKey........................................................................................ 20
2.3.1.15. ACR120_Inc............................................................................................................. 22
2.3.1.16. ACR120_Dec ........................................................................................................... 24
2.3.1.17. ACR120_Copy ......................................................................................................... 26
2.3.1.18. ACR120_Power ....................................................................................................... 28
2.3.1.19. ACR120_ReadUserPort .......................................................................................... 28
2.3.1.20. ACR120_WriteUserPort........................................................................................... 29
2.3.1.21. ACR120_GetID ........................................................................................................ 30
2.3.1.22. ACR120_ListTag...................................................................................................... 31
2.3.1.23. ACR120_MultiTagSelect ......................................................................................... 32
2.3.1.24. ACR120_TxDataTelegram ...................................................................................... 33
2.3.1.25. ACR120_RequestVersionInfo.................................................................................. 34
2.3.1.26. PICC_InitBlockNumber............................................................................................ 34
2.3.1.27. PICC_Xch_APDU .................................................................................................... 36
2.3.1.28. PICC_RATS............................................................................................................. 37
2.3.1.29. PICC_Deselect ........................................................................................................ 38
2.3.1.30. ACR120_ReadATQB............................................................................................... 39
2.3.1.31. ACR120_SetFWI ..................................................................................................... 40
2.3.1.32. ACR120_FlipUserPort ............................................................................................. 41
Appendix A.
Table of Error Codes.................................................................................. 42
Appendix B.
Sector Number Adaptation on Mifare 4K Card........................................ 43
Appendix C.
Physical and Logical Block/Sector Calculation ...................................... 44
Appendix C.1.
Appendix C.2.
Mifare 1K....................................................................................................................44
Mifare 4K....................................................................................................................44
Page 2 of 44
ACR120S Application Programming InterfaceDocument Title Here
Document
Title Here
Version 3.00
info@acs.com.hk
www.acs.com.hk
1.0. Introduction
This manual describes the use of ACR120 interface software to program the ACR120 readers. It
contains a set of library functions implemented for the application programmers to operate the
ACR120 readers and the presented cards. Currently, it is supplied in the form of 32-bit DLL (for
Windows 98/2K/XP). It can be programmed using the popular development tools like Visual C/C++,
Visual Basic, Delphi, etc… ACR120 readers can be connected to the PC via the RS/232 interface.
Application Program
ACR120
Reader
Driver Program
Windows
Operating System
Layer
READER
PC
RS-232
Figure 1:
Architecture of the ACR120 Library
Page 3 of 44
ACR120S Application Programming InterfaceDocument Title Here
Document
Title Here
Version 3.00
info@acs.com.hk
www.acs.com.hk
2.0. ACR120
2.1. Overview
ACR120 contains a set of high-level functions for the application software’s use. It provides a
consistent application programming interface (ACR120 API) for the application to operate on the
ACR120 reader and the corresponding presented card. ACR120 communicates with the ACR120
reader via the communication port facilities provided by the operating system.
2.2. Communication Speed
The ACR120 library controls the communication speed between the reader and the PC. The default
communication baud rate (factory setting) is 9600 bps, no parity, 8 bits and one stop bits. A higher
speed of 115200 bps can be achieved by using software command issuing from the host. If you are
not sure about the factory setting of your readers, you can use the Analyze Reader Function of
ACR120 Tools to detect the current ACR120 reader settings.
2.3. ACR120 API
The ACR120 Application Programming Interface (API) defines a common way of accessing the
ACR120 reader. Application programs invoke ACR120 reader through the interface functions and
perform operations on the presented card.
The header file ACR120.h is available for the program developer, which contains all the function
prototypes and macros described below.
2.3.1.
Interface Function Prototypes
Generally, a program is required to call ACR120_Open first to obtain a handle. The handle is required
for all ACR120 function call except for ACR120_Open.
Note: All Card API’s involving SECTOR and BLOCK parameters please refer to Appendix C
for further explanations.
2.3.1.1.
ACR120_Open
Format:
DLLAPI INT16 AC_DECL ACR120_Open (INT16 ReaderPort,
INT16 BaudRate);
Function Description:
This function opens the port (connection) to ACR120 reader.
Parameters
Description
ReaderPort
The port number where the ACR120 reader is connected
Available choices are “ACR120_COM1” to “ACR120_COM8”
BaudRate
The port baud rate
Available choices are “ACR120_COM_BAUDRATE_9600” to
“ACR120_COM_BAUDRATE_115200”
Return Value
INT16
Result code: 0 means success
Returns:
The return value is zero if the function is successful. Otherwise, it returns a negative value containing
Page 4 of 44
ACR120S Application Programming InterfaceDocument Title Here
Document
Title Here
Version 3.00
info@acs.com.hk
www.acs.com.hk
the error code. For the detailed meaning of the error code, please refer to Appendix A.
Example:
// open a port to an ACR120 reader connected at COM1 with a baud rate of
// 9600 bps.
INT16 rHandle;
rHandle = ACR120_Open(ACR120_COM1,
ACR120_COM_BAUDRATE_9600);
2.3.1.2.
ACR120_Close
Format:
DLLAPI INT16 AC_DECL ACR120_Close (INT16 rHandle);
Function Description:
This function closes the port (connection) to ACR120 reader.
Parameters
Description
rHandle
The handle to ACR120 reader returned by
ACR120_Open
Return Value
INT16
Result code: 0 means success
Returns:
The return value is zero if the function is successful. Otherwise, it returns a negative value containing
the error code. For the detailed meaning of the error code, please refer to Appendix A.
Example:
// close the port (connection) to ACR120 reader.
INT16 RetCode;
RetCode = ACR120_Close (rHandle);
2.3.1.3.
ACR120_Reset
Format:
DLLAPI INT16 AC_DECL ACR120_Reset (INT16 rHandle, UINT8 stationID);
Function Description:
This function resets the reader.
Parameters
rHandle
stationID
Return Value
Description
The handle to ACR120 reader returned by ACR120_Open
The Station ID of ACR120 Reader
INT16
Result code: 0 means success
Page 5 of 44
ACR120S Application Programming InterfaceDocument Title Here
Document
Title Here
Version 3.00
info@acs.com.hk
www.acs.com.hk
Returns:
The return value is zero if the function is successful. Otherwise, it returns a negative value containing
the error code. For the detailed meaning of the error code, please refer to Appendix A.
Example:
// reset the reader (reader stationID:1)
INT16 RetCode;
RetCode = ACR120_Reset (rHandle, 1);
2.3.1.4.
ACR120_Select
Format:
DLLAPI INT16 AC_DECL ACR120_Select ( INT16
UINT8
BOOL*
UINT8*
UINT8
rHandle,
stationID,
pHaveTag,
pTAG,
pSN[ACR120_SN_LEN]);
Function Description:
This function selects a single card in range and returns the card ID (Serial Number).
Parameters
rHandle
stationID
Description
The handle to ACR120 reader returned by ACR120_Open
The Station ID of ACR120 Reader
pHaveTag
Output Variable that will indicate whether the TAG Type Identification
is returned: (TRUE) or (FALSE)
pTAG
Output Variable that will contain the TAG Type Identification if
returned (*pHaveTag = TRUE)
pSN
Output Variable that will contain the card ID (Serial Number)
AC_MIFARE_SN_LEN_4 (4 bytes long)
AC_MIFARE_SN_LEN_7 (7 bytes long)
AC_MIFARE_SN_LEN (10 bytes long)
Return Value
INT16
Result code. 0 means success
Page 6 of 44
ACR120S Application Programming InterfaceDocument Title Here
Document
Title Here
Version 3.00
info@acs.com.hk
www.acs.com.hk
TAG Type Identification:
Tag Type Value
0x01
0x02
0x03
0x04
0x05
0x06
0x07
0x08
0x80
Tag Type Description
Serial Number Length
Mifare Light
Mifare 1K
Mifare 4K
Mifare DESFire
Mifare UltrLight
JCOP30
Shanghai Transport
MPCOS Combi
ISO type B, Calypso
4
4
4
7
7
4
4
4
4
Returns:
The return value is zero if the function is successful. Otherwise, it returns a negative value containing
the error code. For the detailed meaning of the error code, please refer to Appendix A.
Notes:
You have to select the card first before you can Login and manipulate the card.
When there’s more than one card in antenna range, you can use ACR120_MultiTagSelect.
Example:
// Select a single card in range (reader stationID: 1)
INT16 RetCode;
UINT8 SID;
BOOL pHaveTag;
UINT8 pTAG;
UINT8 pSN[3];
CString StrMsg;
SID = 1;
RetCode = ACR120_Select (rHandle, SID, &pHaveTag, &pTAG, pSN);
// Get Serial Number Returned
StrMsg.Format("Card Serial: %X %X %X %X",pSN[0],pSN[1],pSN[2],pSN[3]);
2.3.1.5.
ACR120_Login
Format:
DLLAPI INT16 AC_DECL ACR120_Login ( INT16
UINT8
UINT8
UINT8
INT
UINT8
rHandle,
stationID,
sector,
keyType,
storedNo,
pKey[ACR120_KEY_LEN]);
Function Description:
This function performs authentication to access one sector of the card. Only one sector can be
accessed at a time.
Page 7 of 44
ACR120S Application Programming InterfaceDocument Title Here
Document
Title Here
Version 3.00
info@acs.com.hk
www.acs.com.hk
Parameters
rHandle
stationID
Sector *
keyType
storedNo
pKey
Return Value
Description
The handle to ACR120 reader returned by ACR120_Open
The Station ID of ACR120 Reader.
The sector number to login in.
The type of key. It can be: ACR120_LOGIN_KEYTYPE_AA
ACR120_LOGIN_KEYTYPE_BB
ACR120_LOGIN_KEYTYPE_FF
ACR120_LOGIN_KEYTYPE_STORED_A
ACR120_LOGIN_KEYTYPE_STORED_B
The stored no. of key to use, IF keyType =
ACR120_LOGIN_KEYTYPE_STORED_A or
ACR120_LOGIN_KEYTYPE_STORED_B
The login key, IF keyType = ACR120_LOGIN_KEYTYPE_AA or
ACR120_LOGIN_KEYTYPE_BB
ACR120_KEY_LEN is 6 bytes long
INT16
Result code. 0 means success
* Please refer to Appendix Bfor logging in Mifare 4K cards.
Returns:
The return value is zero if the function is successful. Otherwise, it returns a negative value containing
the error code. For the detailed meaning of the error code, please refer to appendix A.
Notes:
If keyType = ACR120_LOGIN_KEYTYPE_AA, or
If keyType = ACR120_LOGIN_KEYTYPE_BB,
Then storedNo. will not be used and can be just zero. While pKey must contain the 6 bytes
key.
If keyType = ACR120_LOGIN_KEYTYPE_FF
Then the transport code: 0xFF 0xFF 0xFF 0xFF 0xFF 0xFF will be use.
If keyType = ACR120_LOGIN_KEYTYPE_STORED_A, or
If keyType = ACR120_LOGIN_KEYTYPE_STORED_B,
Then pKey will not bed use and can be just zero’s while storedNo is the keyNo of the
MasterKey you want to use. (Refer to ACR120_WriteMasterKey)
Before you can manipulate the card, e.g. read, write, copy, readvalue, writevalue, etc., you have to be
able to successfully login first to the card sector that you want to manipulate.
Example:
// Login to sector 1 using keyType ACR120_LOGIN_KEYTYPE_AA
// (reader stationID: 1)
INT16 RetCode;
UINT8 SID;
UINT8 sector;
UINT8 keyType;
Int storedNo;
UINT8
pKey[5];
SID = 1;
sector = 1;
keyType = ACR120_LOGIN_KEYTYPE_AA
storedNo = 0;
Page 8 of 44
ACR120S Application Programming InterfaceDocument Title Here
Document
Title Here
Version 3.00
info@acs.com.hk
www.acs.com.hk
pKey[0]
pKey[1]
pKey[2]
pKey[3]
pKey[4]
pKey[5]
=
=
=
=
=
=
255;
255;
255;
255;
255;
255;
RetCode = ACR120_Login(rHandle, SID, sector, keyType, storedNo, pKey);
// Login to sector 1 using keyType ACR120_LOGIN_KEYTYPE_FF
// (reader stationID: 1)
INT16 RetCode;
UINT8 SID;
UINT8 sector;
UINT8 keyType;
Int storedNo;
UINT8 pKey[5];
SID = 1;
sector = 1;
keyType = ACR120_LOGIN_KEYTYPE_AA
storedNo = 0;
RetCode = ACR120_Login(rHandle, SID, sector, keyType, storedNo, pKey);
// Login to sector 1 using keyType ACR120_LOGIN_KEYTYPE_STORED_A
// masterkey is stored to ( keyNo: 3 ) using the ACR120_WriteMasterKey
// (reader stationID: 1)
INT16 RetCode;
UINT8 SID;
UINT8 sector;
UINT8 keyType;
Int storedNo;
UINT8 pKey[5];
SID = 1;
sector = 1;
keyType = ACR120_LOGIN_KEYTYPE_STORED_A
storedNo = 3;
RetCode = ACR120_Login(rHandle, SID, sector, keyType, storedNo, pKey);
2.3.1.6.
ACR120_Read
Format:
DLLAPI INT16 AC_DECL ACR120_Read ( INT16
UINT8
UINT8
UINT8
rHandle,
stationID,
block,
pBlockData[ACR120_DATA_LEN]);
Page 9 of 44
ACR120S Application Programming InterfaceDocument Title Here
Document
Title Here
Version 3.00
info@acs.com.hk
www.acs.com.hk
Function Description:
This function reads a block within the sector where you Login.
Parameters
Description
rHandle
The handle to ACR120 reader returned by
ACR120_Open
stationID
The Station ID of ACR120 Reader.
block
The block number you want to read.
pBlockData
Output Variable that will Contain the data read.
ACR120_DATA_LEN is 16 bytes long.
Return Value
INT16
Result code. 0 means success.
Returns:
The return value is zero if the function is successful. Otherwise, it returns a negative value containing
the error code. For the detailed meaning of the error code, please refer to Appendix A.
Notes:
Memory Organization is based from Standard Card IC MF1 IC S50, which have 16 sectors with 4
blocks of 16 bytes each.
Byte Number within a Block
Sector
15
14
Block
3
2
1
0
3
2
1
0
:
:
:
:
:
1
:
3
2
1
0
3
2
1
0
0
0
1
2 3 4
Key A
5
6
7 8 9 10
Access Bits
11
12
13 14
Key B
Key A
Access Bits
Key B
Key A
Access Bits
Key B
Key A
Access Bits
Key B
15
For you to access the exact block, you have to multiply the sector number by 4 plus the block number:
Block = (Sector * 4) + BlockNumber
Page 10 of 44
ACR120S Application Programming InterfaceDocument Title Here
Document
Title Here
Version 3.00
info@acs.com.hk
www.acs.com.hk
Example:
// Read block 1 of sector 1 (reader stationID: 1)
// let’s assume we’ve successfully Login to sector 1
INT16 RetCode;
UINT8 SID;
UINT8 block;
UINT8 pBlockData[16];
CString StrMsg;
SID = 1;
block = (1 * 4) + 1
RetCode = ACR120_Read(rHandle, SID, block, pBlockData);
// Data Read
StrMsg.Format("Data Read: %X %X %X %X %X
%X
%X %X %X %X %X
%X %X %X %X %X",
pBlockData[0],pBlockData[1],
pBlockData[2],pBlockData[3],
pBlockData[4], pBlockData[5],
pBlockData[6], pBlockData[7]
pBlockData[8], pBlockData[9],
pBlockData[10],pBlockData[11],
pBlockData[12],pBlockData[13],
pBlockData[14],pBlockData[15]);
// Read block 2 of sector 4 (reader stationID: 1)
// let’s assume we’ve successfully Login to sector 4
INT16 RetCode;
UINT8 SID;
UINT8 block;
UINT8 pBlockData[16];
CString StrMsg;
SID = 1;
block = (4 * 4) + 2
RetCode = ACR120_Read(rHandle, SID, block, pBlockData);
// Data Read
StrMsg.Format("Data Read: %X %X %X %X %X
%X
%X %X %X %X %X
%X %X %X %X %X",
pBlockData[0],pBlockData[1],
pBlockData[2],pBlockData[3],
pBlockData[4], pBlockData[5],
pBlockData[6], pBlockData[7]
pBlockData[8], pBlockData[9],
pBlockData[10],pBlockData[11],
pBlockData[12],pBlockData[13],
pBlockData[14],pBlockData[15]);
Page 11 of 44
ACR120S Application Programming InterfaceDocument Title Here
Document
Title Here
Version 3.00
info@acs.com.hk
www.acs.com.hk
2.3.1.7.
ACR120_ReadValue
Format:
DLLAPI INT16 AC_DECL ACR120_ReadValue( INT16
UINT8
UINT8
INT32*
rHandle,
stationID,
block,
pValueData);
Function Description:
This function reads value block within the sector where you Login.
Parameters
rHandle
stationID
block
pValueData
Return Value
Description
The handle to ACR120 reader returned by ACR120_Open
The Station ID of ACR120 Reader
The value block number you want to read
Output Variable that will contain the value read
INT16
Result code; 0 means success
Returns:
The return value is zero if the function is successful. Otherwise, it returns a negative value containing
the error code. For the detailed meaning of the error code, please refer to Appendix A.
Notes:
Memory Organization is based on Standard Card IC MF1 IC S50, which have 16 sectors with 4 blocks
of 16 bytes each.
Byte Number within a Block
Sector
15
14
Block
3
2
1
0
3
2
1
0
:
:
:
:
:
1
:
3
2
1
0
3
2
1
0
0
0
1
2 3 4
Key A
5
6
7 8 9 10
Access Bits
11
12
13 14
Key B
Key A
Access Bits
Key B
Key A
Access Bits
Key B
Key A
Access Bits
Key B
15
Page 12 of 44
ACR120S Application Programming InterfaceDocument Title Here
Document
Title Here
Version 3.00
info@acs.com.hk
www.acs.com.hk
For you to access the exact block, you have to multiply the sector number by 4 plus the block number:
Block = (Sector * 4) + BlockNumber.
The difference between the ACR120_Read and ACR120_ReadValue is that the ACR120_Read reads
the 16 Bytes data within the block while ACR120_ReadValue reads the INT32 value in the value
block (block that was formatted by ACR120_WriteValue). “The block must be a value before
reading; refer to ACR120_WriteValue”
Example:
// Read value of block 1 of sector 1 (reader stationID: 1)
// Let’s assume logging into sector 1 was successful and a value is written
// to block 1 using ACR120_WriteValue
INT16 RetCode;
UINT8 SID;
UINT8 block;
UINT32 pValueData;
CString StrMsg;
SID = 1;
block = (1 * 4) + 1
RetCode = ACR120_ReadValue(rHandle, SID, block, &pValueData);
// Value Read
StrMsg.Format("Value Read: %d”,pValueData);
// Read value of block 2 of sector 4 (reader stationID: 1)
// Let’s assume logging into sector 4 was successful and a value is written
// to block 2 using ACR120_WriteValue
INT16 RetCode;
UINT8 SID;
UINT8 block;
UINT32 pValueData;
CString StrMsg;
SID = 1;
block = (4 * 4) + 2;
RetCode = ACR120_ReadValue(rHandle, SID, block, &pValueData);
// Value Read
StrMsg.Format("Value Read: %d”, pValueData);
2.3.1.8.
ACR120_ReadEEPROM
Format:
DLLAPI INT16 AC_DECL ACR120_ReadEEPROM ( INT16
UINT8
UINT8
UINT8*
rHandle,
stationID,
reg,
pEEPROMData);
Function Description:
This function reads the internal EEPROM of the ACR120 reader
Page 13 of 44
ACR120S Application Programming InterfaceDocument Title Here
Document
Title Here
Version 3.00
info@acs.com.hk
www.acs.com.hk
Parameters
rHandle
stationID
reg
pEEPROMData
Return Value
Description
The handle to ACR120 reader returned by ACR120_Open
The Station ID of ACR120 Reader
The register number
Output Variable that will Contain the EEPROM register’s value
INT16
Result code; 0 means success
Returns:
The return value is zero if the function is successful. Otherwise, it returns a negative value containing
the error code. For the detailed meaning of the error code, please refer to Appendix A.
Notes:
The details for the register map is shown below:
ACR120 Reader Module EEPROM Memory Organization
Register Number
Name
Description
00h…03h
Unique device ID (32bit)
This number is unique for each device and
therefore read only
04h
Station ID
Indicates the address ID for every station. The
ID is used for addressing within a party line
05h
Protocol Configuration
Set Protocol type, power on behavior.
00h -> ACR120 reader in ASCII mode
01h -> ACR120 reader in Binary mode
Defines Communication speed
00h -> 9600 baud
06h
Baud Rate Selection
01h -> 19200 baud
02h -> 38400 baud
03h -> 57600 baud
07h…0Fh
Reserved
10h…13h
User Date
Free Usage
Example:
// Read Baud rate (register 06h) of EEPROM (reader stationID: 1)
INT16 RetCode;
UINT8 SID;
UINT8 reg;
UINT8 pEEPROMData;
CString StrMsg;
SID = 1;
reg = 6;
Page 14 of 44
ACR120S Application Programming InterfaceDocument Title Here
Document
Title Here
Version 3.00
info@acs.com.hk
www.acs.com.hk
RetCode = ACR120_ReadEEPROM (rHandle, SID, reg, &pEEPROMData);
// Value Read
StrMsg.Format("EEPROM Data Read:: %d”,pEEPROMData);
2.3.1.9.
ACR120_ReadLowLevelRegister
Format:
ACR120_DLLAPI INT16 ACR120_DECLACR120_ReadLowLevelRegister(
INT16
hReader,
UINT8
stationID,
UINT8
reg,
UINT8*
pRegData);
* This command should be used under manufacturer’s recommendation.
Function Description:
This function reads the internal register value.
Parameters
Description
hReader
The handle to our reader returned by ACR120_Open
stationID
The station ID of our reader
reg
The register number
pRegData
Contains the register’s value
Return Value
INT16
Result code; 0 means success
2.3.1.10. ACR120_Write
Format:
DLLAPI INT16 AC_DECL ACR120_Write ( INT16
UINT8
UINT8
UINT8
rHandle,
stationID,
block,
pBlockData[ACR120_DATA_LEN]);
Function Description:
This function reads a block within the sector where you Login.
Parameters
rHandle
stationID
block
pBlockData
Return Value
Description
The handle to ACR120 reader returned by
ACR120_Open
The Station ID of ACR120 Reader
The block number where you want to write
The 16 bytes Data to Write
ACR120_DATA_LEN is 16 bytes long
INT16
Result code; 0 means success
Returns:
The return value is zero if the function is successful. Otherwise, it returns a negative value containing
the error code. For the detailed meaning of the error code, please refer to Appendix A.
Notes:
Page 15 of 44
ACR120S Application Programming InterfaceDocument Title Here
Document
Title Here
Version 3.00
info@acs.com.hk
www.acs.com.hk
Memory Organization is based on Standard Card IC MF1 IC S50, which have 16 sectors with 4 blocks
of 16 bytes each.
Byte Number within a Block
Sector
15
14
Block
3
2
1
0
3
2
1
0
:
:
:
:
:
1
:
3
2
1
0
3
2
1
0
0
0
1
2 3 4
Key A
5
6
7 8 9 10
Access Bits
11
12
13 14
Key B
Key A
Access Bits
Key B
Key A
Access Bits
Key B
Key A
Access Bits
Key B
15
For you to access the exact block, you have to multiply the sector number by 4 plus the block number:
Block = (Sector * 4) + BlockNumber
Example:
// Write to block 1 of sector 1 (reader stationID: 1)
// Let’s assume logging into sector 1 was successful
INT16 RetCode;
UINT8 SID;
UINT8 block;
UINT8 pBlockData[16];
CString StrMsg;
SID = 1;
block = (1 * 4) + 1
pBlockData[0]
pBlockData[1]
pBlockData[2]
pBlockData[3]
pBlockData[4]
pBlockData[5]
pBlockData[6]
=
=
=
=
=
=
=
255;
255;
255;
255;
255;
255;
255;
Page 16 of 44
ACR120S Application Programming InterfaceDocument Title Here
Document
Title Here
Version 3.00
info@acs.com.hk
www.acs.com.hk
pBlockData[7] = 255;
pBlockData[8] = 255;
pBlockData[9] = 255;
pBlockData[10] = 255;
pBlockData[11] = 255;
pBlockData[12] = 255;
pBlockData[13] = 255;
pBlockData[14] = 255;
pBlockData[15] = 255;
RetCode = ACR120_Write(rHandle, SID, block, pBlockData);
2.3.1.11. ACR120_WriteValue
Format:
DLLAPI INT16 AC_DECL ACR120_WriteValue( INT16
UINT8
UINT8
INT32
rHandle,
stationID,
block,
ValueData);
Function Description:
This function writes INT32 value to a block within the sector where you Login.
Parameters
rHandle
stationID
block
ValueData
Return Value
Description
The handle to ACR120 reader returned by ACR120_Open
The Station ID of ACR120 Reader
The block number where you want to write
The value you want to write
INT16
Result code; 0 means success
Returns:
The return value is zero if the function is successful. Otherwise, it returns a negative value containing
the error code. For the detailed meaning of the error code, please refer to Appendix A.
Notes:
Memory Organization is based on Standard Card IC MF1 IC S50, which are 16 sectors with 4 blocks
of 16 bytes each.
Page 17 of 44
ACR120S Application Programming InterfaceDocument Title Here
Document
Title Here
Version 3.00
info@acs.com.hk
www.acs.com.hk
Byte Number within a Block
Sector
15
14
Block
3
2
1
0
3
2
1
0
:
:
:
:
:
1
:
3
2
1
0
3
2
1
0
0
0
1
2 3 4
Key A
5
6
7 8 9 10
Access Bits
11
12
13 14
Key B
Key A
Access Bits
Key B
Key A
Access Bits
Key B
Key A
Access Bits
Key B
15
For you to access the exact block, you have to multiply the sector number by 4 plus the block number:
Block = (Sector * 4) + BlockNumber.
Example:
// write value to block 1 of sector 1 (reader stationID: 1)
// Let’s assume logging into sector 1 was successful
INT16 RetCode;
UINT8 SID;
UINT8 block;
UINT32 ValueData;
CString StrMsg;
SID = 1;
block = (1 * 4) + 1;
ValueData = 5000;
RetCode = ACR120_WriteValue(rHandle, SID, block, ValueData);
Page 18 of 44
ACR120S Application Programming InterfaceDocument Title Here
Document
Title Here
Version 3.00
info@acs.com.hk
www.acs.com.hk
2.3.1.12. ACR120_WriteEEPROM
Format:
DLLAPI INT16 AC_DECL ACR120_WriteEEPROM ( INT16
UINT8
UINT8
UINT8
rHandle,
stationID,
reg,
EEPROMData);
Function Description:
This function writes to internal EEPROM of the ACR120 reader.
Parameters
Description
rHandle
The handle to ACR120 reader returned by ACR120_Open
stationID
The Station ID of ACR120 Reader
reg
The register number
EEPROMData
The value to write at the ACR120 reader EEPROM reg
Return Value
INT16
Result code; 0 means success
Returns:
The return value is zero if the function is successful. Otherwise, it returns a negative value containing
the error code. For the detailed meaning of the error code, please refer to Appendix A.
Notes:
The details for the register map is shown below:
ACR120 Reader Module EEPROM Memory Organization
Register Number
Name
Description
00h…03h
Unique device ID (32bit)
This number is unique for each device and
therefore read only.
04h
Station ID
Indicates the address ID for every station. The
ID is used for addressing within a party line.
05h
Protocol Configuration
06h
Baud Rate Selection
07h…0Fh
Reserved
10h…13h
User Date
Set Protocol type, power on behavior.
00h -> ACR120 reader in ASCII mode
01h -> ACR120 reader in Binary mode
Defines Communication speed.
00h -> 9600 baud
01h -> 19200 baud
02h -> 38400 baud
03h -> 57600 baud
Free Usage
Page 19 of 44
ACR120S Application Programming InterfaceDocument Title Here
Document
Title Here
Version 3.00
info@acs.com.hk
www.acs.com.hk
Example:
// Write/Set Baud rate to 57600,
// stationID: 1)
(register 06h) of EEPROM (reader
INT16 RetCode;
UINT8 SID;
UINT8 reg;
UINT8 EEPROMData;
CString StrMsg;
SID = 1;
reg = 6;
EEPROMData = 3;
RetCode = ACR120_WriteEEPROM (rHandle, SID, reg, EEPROMData);
2.3.1.13. ACR120_WriteLowLevelRegister
Format:
ACR120_DLLAPI INT16 ACR120_DECLACR120_WriteLowLevelRegister(
INT16
hReader,
UINT8
stationID,
UINT8
reg,
UINT8
registerData);
Function Description:
This function writes the internal register.
Parameters
Description
hReader
The handle to our reader returned by ACR120_Open
stationID
The station ID of our reader
reg
The register number
registerData
Contains the register’s value to write
Return Value
INT16
Result code; 0 means success
* This command should be used under manufacturer’s recommendation.
2.3.1.14. ACR120_WriteMasterKey
Format:
DLLAPI INT16 AC_DECL ACR120_WriteMasterKey ( INT16
rHandle,
UINT8
stationID,
UINT8
keyNo,
UINT8
pKey[ACR120_KEY_LEN]);
Page 20 of 44
ACR120S Application Programming InterfaceDocument Title Here
Document
Title Here
Version 3.00
info@acs.com.hk
www.acs.com.hk
Function Description:
This function writes Master key to internal EEPROM of the ACR120 reader.
Parameters
Description
rHandle
The handle to ACR120 reader returned by AC120_Open
stationID
The Station ID of ACR120 Reader
keyNo
The master key number
pKey
6 bytes key to write
Return Value
IN16
Result code; 0 means success
Returns:
The return value is zero if the function is successful. Otherwise, it returns a negative value containing
the error code. For the detailed meaning of the error code, please refer to Appendix A.
Notes:
ACR120 reader currently can store up to 32 keys (0 - 31). Keys stored in the reader can be used to
Login to a card sector by using the KeyType ACR120_LOGIN_KEYTYPE_STORED_A or
ACR120_LOGIN_KEYTYPE_STORED_B.
Example:
// Write master key: AAh AAh AAh AAh AAh AAh ; keyNO:2 (reader stationID:
// 1)
INT16 RetCode;
UINT8 SID;
UINT8 keyNo;
UINT8 pKey(5);
CString StrMsg;
SID = 1;
keyNo = 2;
pKey[0]=170;
pKey[1]=170;
pKey[2]=170;
pKey[3]=170;
pKey[4]=170;
pKey[5]=170;
RetCode = ACR120_WriteMasterKey (rHandle, SID, keyNo, pKey);
Page 21 of 44
ACR120S Application Programming InterfaceDocument Title Here
Document
Title Here
Version 3.00
info@acs.com.hk
www.acs.com.hk
2.3.1.15. ACR120_Inc
Format:
DLLAPI INT16 AC_DECL ACR120_Inc (INT16 rHandle,
UINT8 stationID,
UINT8 block,
INT32
value,
INT32* pNewValue);
Function Description:
This function Increments a value block by adding a value to previously stored value.
Parameters
Description
rHandle
stationID
block
value
The handle to ACR120 reader returned by ACR120_Open
The Station ID of ACR120 Reader
Value Block Number
Value to be added to previously stored value in the block
pNewValue
The updated value after increment
Return Value
INT16
Result code; 0 means success
Returns:
The return value is zero if the function is successful. Otherwise, it returns a negative value containing
the error code. For the detailed meaning of the error code, please refer to Appendix A.
Page 22 of 44
ACR120S Application Programming InterfaceDocument Title Here
Document
Title Here
Version 3.00
info@acs.com.hk
www.acs.com.hk
Notes:
Memory Organization is based on Standard Card IC MF1 IC S50, which are 16 sectors with 4 blocks
of 16 bytes each.
Byte Number within a Block
Sector
15
14
Block
3
2
1
0
3
2
1
0
:
:
:
:
:
1
:
3
2
1
0
3
2
1
0
0
0
1
2 3 4
Key A
5
6
7 8 9 10
Access Bits
11
12
13 14
Key B
Key A
Access Bits
Key B
Key A
Access Bits
Key B
Key A
Access Bits
Key B
15
Block must contain a Value before Incrementing.
Please refer to ACR120_WriteValue.
Example:
// Increment value block 1 of sector 1 by 500. (reader stationID: 1)
INT16 RetCode;
UINT8 SID;
UINT8 block;
UINT8 value;
UINT8 pNewValue;
CString StrMsg;
SID = 1;
Block = ( 1 * 4 ) + 1;
value = 500;
RetCode = ACR120_Inc (rHandle, SID, block, value, &pNewValue);
// Updated Value after increment
StrMsg.Format("Incremented Value: %d”,pNewValue);
Page 23 of 44
ACR120S Application Programming InterfaceDocument Title Here
Document
Title Here
Version 3.00
info@acs.com.hk
www.acs.com.hk
2.3.1.16. ACR120_Dec
Format:
DLLAPI INT16 AC_DECL ACR120_Dec (INT16 rHandle,
UINT8 stationID,
UINT8 block,
INT32
value,
INT32* pNewValue);
Function Description:
This function decrements a value block by subtracting a value to previously stored value.
Parameters
Description
rHandle
stationID
block
value
The handle to ACR120 reader returned by ACR120_Open
The Station ID of ACR120 Reader.
Value Block Number.
Value to be subtracted to previously stored value in the block.
pNewValue
The updated value after decrement.
Return Value
INT16
Result code. 0 means success.
Returns:
The return value is zero if the function is successful. Otherwise, it returns a negative value containing
the error code. For the detailed meaning of the error code, please refer to Appendix A.
Page 24 of 44
ACR120S Application Programming InterfaceDocument Title Here
Document
Title Here
Version 3.00
info@acs.com.hk
www.acs.com.hk
Notes:
Memory Organization is based on Standard Card IC MF1 IC S50, which are 16 sectors with 4 blocks
of 16 bytes each.
Byte Number within a Block
Sector
15
14
Block
3
2
1
0
3
2
1
0
:
:
:
:
:
1
:
3
2
1
0
3
2
1
0
0
0
1
2 3 4
Key A
5
6
7 8 9 10
Access Bits
11
12
13 14
Key B
Key A
Access Bits
Key B
Key A
Access Bits
Key B
Key A
Access Bits
Key B
15
Block must contain a Value before decrementing.
“Refer to ACR120_WriteValue”.
Example:
// decrement value block 1 of sector 1 by 500. (reader stationID: 1)
INT16 RetCode;
UINT8 SID;
UINT8 block;
UINT8 value;
UINT8 pNewValue;
CString StrMsg;
SID = 1;
Block = ( 1 * 4 ) + 1;
value = 500;
RetCode = ACR120_dec (rHandle, SID, block, value, &pNewValue);
// Updated Value after decrement
StrMsg.Format("Decremented Value: %d”,pNewValue);
Page 25 of 44
ACR120S Application Programming InterfaceDocument Title Here
Document
Title Here
Version 3.00
info@acs.com.hk
www.acs.com.hk
2.3.1.17. ACR120_Copy
Format:
DLLAPI INT16 AC_DECL ACR120_Copy (INT16
UINT8
UINT8
UINT8
INT32*
rHandle,
stationID,
srcBlock,
desBlock,
pNewValue);
Function Description:
This function copies a value block to another block of the same sector.
Parameters
Description
rHandle
stationID
srcBlock
desBlock
The handle to ACR120 reader returned by ACR120_Open
The Station ID of ACR120 Reader
The source block number
The target block number
pNewValue
Return Value
The updated value after copy
INT16
Result code; 0 means success
Returns:
The return value is zero if the function is successful. Otherwise, it returns a negative value containing
the error code. For the detailed meaning of the error code, please refer to Appendix A.
Page 26 of 44
ACR120S Application Programming InterfaceDocument Title Here
Document
Title Here
Version 3.00
info@acs.com.hk
www.acs.com.hk
Notes:
Memory Organization is based on Standard Card IC MF1 IC S50, which are 16 sectors with 4 blocks
of 16 bytes each.
Byte Number within a Block
Sector
15
14
Block
3
2
1
0
3
2
1
0
:
:
:
:
:
1
:
3
2
1
0
3
2
1
0
0
0
1
2 3 4
Key A
5
6
7 8 9 10
Access Bits
11
12
13 14
Key B
Key A
Access Bits
Key B
Key A
Access Bits
Key B
Key A
Access Bits
Key B
15
Source block must contain a Value before copying to another block in the same sector. Refer to
ACR120_WriteValue
The destination or target block need not to be a value block.
Example:
// copy value block 1 of sector 1 to block 2 of sector 1. (reader
// stationID: 1)
// Lets assume that logging into sector 1 was successful and block one is a
value block. “Refer to ACR120_WriteValue”.
INT16 RetCode;
UINT8 SID;
UINT8 srcBlock;
UINT8 desBlock;
UINT8 pNewValue;
CString StrMsg;
SID = 1;
srcBlock = ( 1 * 4 ) + 1;
desBlock= ( 1 * 4 ) + 2;
RetCode = ACR120_Copy(rHandle, SID, srcBlock, desBlock, &pNewValue);
// Updated Value of target block after copy.
StrMsg.Format("Block 2 Value: %d”,pNewValue);
Page 27 of 44
ACR120S Application Programming InterfaceDocument Title Here
Document
Title Here
Version 3.00
info@acs.com.hk
www.acs.com.hk
2.3.1.18. ACR120_Power
Format:
DLLAPI INT16 AC_DECL ACR120_Power (INT16
UINT8
BOOL
rHandle,
stationID,
bOn);
Function Description:
This function is used to turn the antenna power on/off for reducing power consumption.
Parameters
RHandle
stationID
bOn
Return Value
Description
The handle to ACR120 reader returned by ACR120_Open
The Station ID of ACR120 Reader
Turn on (TRUE) or off (FALSE)
INT16
Result code; 0 means success
Returns:
The return value is zero if the function is successful. Otherwise, it returns a negative value containing
the error code. For the detailed meaning of the error code, please refer to Appendix A.
Notes:
The antenna power will be turned on automatically before TAG access commands like
"ACR120_Select" and "ACR120_MultiTagSelect".
Example:
// Turns antenna power off (reader stationID: 1)
INT16 RetCode;
UINT8 SID;
BOOL bOn;
SID = 1;
bOn = false;
RetCode = ACR120_Power (rHandle, SID,bOn);
// Turns antenna power on (reader stationID: 1)
INT16 RetCode;
UINT8 SID;
BOOL bOn;
SID = 1;
bOn = true;
RetCode = ACR120_Power (rHandle, SID,bOn);
2.3.1.19. ACR120_ReadUserPort
Format:
DLLAPI INT16 AC_DECL ACR120_ReadUserPort (INT16 rHandle,
UINT8 stationID,
UINT8* pUserPortState);
Function Description:
This function is used to read in the state of user port (PIN 14 of the OEM module).
Page 28 of 44
ACR120S Application Programming InterfaceDocument Title Here
Document
Title Here
Version 3.00
info@acs.com.hk
www.acs.com.hk
Parameters
RHandle
stationID
pUserPortState
Return Value
Description
The handle to ACR120 reader returned by ACR120_Open
The Station ID of ACR120 Reader
Contains the port state (only LSB is used)
INT16
Result code; 0 means success
Returns:
The return value is zero if the function is successful. Otherwise, it returns a negative value containing
the error code. For the detailed meaning of the error code, please refer to Appendix A.
Example:
// Read User port (reader stationID: 1)
INT16 RetCode;
UINT8 SID;
UINT8 pUserPortState;
SID = 1;
RetCode = ACR120_ReadUserPort (rHandle, SID, &pUserPortState);
2.3.1.20. ACR120_WriteUserPort
Format:
DLLAPI INT16 AC_DECL ACR120_WriteUserPort (INT16
UINT8
UINT8
rHandle,
stationID,
userPortState);
Function Description:
For ACR120S, this function sets the state of the LED.
For ACM120S-SM, a relay is tied to the LED control. An additional control is made available for
controlling the on board buzzer. This function sets the states of Relay (together with LED) and
Buzzer.
Note: The LED state of some readers may have been tied to indicate operation status by
software option in factory default. In this case, the user may not be able to change the
Relay/LED independently. To release this tie, please use the ACR120_WRITEEEPROM
function to write a value of 0x00 to a special EEPROM address of 0xFE then do a power
reset to the reader. Doing this operation only once is enough to change the option
permanently.
Page 29 of 44
ACR120S Application Programming InterfaceDocument Title Here
Document
Title Here
Version 3.00
info@acs.com.hk
www.acs.com.hk
Parameters
Description
RHandle
The handle to ACR120 reader returned by ACR120_Open
stationID
The Station ID of ACR120 Reader
userPortState
Return Value
Value
0x00
0x01
0x02
0x03
INT16
Action
Relay/LED and Buzzer OFF
Relay/LED ON, Buzzer OFF
Relay/LED OFF Buzzer ON
Relay/LED and Buzzer ON
Result code; 0 means success
Returns:
The return value is zero if the function is successful. Otherwise, it returns a negative value containing
the error code. For the detailed meaning of the error code, please refer to Appendix A.
Example:
// Clear User port (reader stationID: 1)
INT16 RetCode;
UINT8 SID;
UINT8 userPortState;
SID = 1;
userPortState = 0;
RetCode = ACR120_WriteUserPort (rHandle, SID, userPortState);
2.3.1.21. ACR120_GetID
Format:
DLLAPI INT16 AC_DECL ACR120_GetID (INT16 rHandle,
UINT8* pNumID,
UINT8* pStationID);
Function Description:
This function gets the station ID’s for all reader modules on the bus.
Parameters
rHandle
pNumID
pStationID
Return Value
Description
The handle to ACR120 reader returned by ACR120_Open
The number of station ID returned
Contains the list of station ID returned
INT16
Result code; 0 means success
Returns:
The return value is zero if the function is successful. Otherwise, it returns a negative value containing
the error code. For the detailed meaning of the error code, please refer to Appendix A.
Page 30 of 44
ACR120S Application Programming InterfaceDocument Title Here
Document
Title Here
Version 3.00
info@acs.com.hk
www.acs.com.hk
Example:
// Get station ID’s
INT16 RetCode;
UINT8 pNumID;
UINT8 pStationID[255];
RetCode = ACR120_GetID(rHandle, &pNumID, pStationID);
2.3.1.22. ACR120_ListTag
Format:
DLLAPI INT16 AC_DECL ACR120_ListTag( INT16
UINT8
UINT8*
BOOL*
UINT8*
UINT8*
rHandle,
stationID,
pNumTagFound,
pHaveTag,
pTAG,
pSN);
Function Description:
This function lists the serial numbers of all tags, which are in readable antenna range.
Parameters
rHandle
stationID
pNumTagFound
pHaveTag
pTAG
pSN
Return Value
Description
The handle to ACR120 reader returned by ACR120_Open
The Station ID of ACR120 Reader
Contains of number of TAG listed
Whether the TAG Type Identification is listed
The list of TAG Type Identification
If pHaveTag is false, this is an array of serial number length of the
cards detected.
If pHaveTag is true, this is an array of Tag type. The corresponding
serial number length could then be determined from the Tag type.
The flat array of serial numbers. All serial numbers are concatenated
with length of 4, 7 or 10 numbers. The lengths are indicated in
pTag field.
INT16
Result code; 0 means success
Returns:
The return value is zero if the function is successful. Otherwise, it returns a negative value containing
the error code. For the detailed meaning of the error code, please refer to appendix A.
Example:
// List all Tag’s in antenna range (stationID: 1)
INT16 RetCode;
UINT8 SID;
UINT8* pNumTagFound;
BOOL* pHaveTag;
UINT8* pTAG;
UINT8* pSN[199];
UINT8 ctr;
UINT8 ctr1;
SID=1;
Page 31 of 44
ACR120S Application Programming InterfaceDocument Title Here
Document
Title Here
Version 3.00
info@acs.com.hk
www.acs.com.hk
RetCode
pSN);
=
ACR120_ListTag(rHandle,
SID,
&pNumTagFound,
&pHaveTag,
&pTAG,
StrMsg.Format("Number of Tag Found: %d", pNumTagFound);
//Display Serial Numbers Found
// Loop to Number of TagFound (pNUmTagFound)
ctr1 = 0;
for( ctr = 0 ; ctr < pNumTagFound; ctr++)
{
StrMsg.Format("SN[%d]:
%X
%X
SN[ctr1+0],SN[ctr1+1],SN[ctr1+2],SN[ctr1+3]);
ctr1 += 4;
}
%X
%X",
ctr,
2.3.1.23. ACR120_MultiTagSelect
Format:
DLLAPI INT16 AC_DECL ACR120_MultiTagSelect( INT16
rHandle,
UINT8 stationID,
UINT8 pSN[ACR120_SN_LEN],
BOOL* pHaveTag,
UINT8*
pTAG,
UINT8 pResultSN[ACR120_SN_LEN]);
Function Description:
This function selects a single card in range and returns the card ID (Serial Number).
Parameters
rHandle
stationID
pSN
pHaveTag
pTAG
pResultSN
Return Value
Description
The handle to ACR120 reader returned by ACR120_Open
The Station ID of ACR120 Reader
Contains the serial number of the TAG to be selected. It’s
ACR120_SN_LEN is 4 bytes long.
AC_MIFARE_SN_LEN_4 (4 bytes long),
AC_MIFARE_SN_LEN_7 (7 bytes long),
AC_MIFARE_SN_LEN (10 bytes long).
Whether the TAG Type Identification of selected tag is returned
The TAG Type Identification of selected tag
The serial number of selected TAG. It’s ACR120_SN_LEN is 4 bytes
long.
AC_MIFARE_SN_LEN_4 (4 bytes long),
AC_MIFARE_SN_LEN_7 (7 bytes long),
AC_MIFARE_SN_LEN (10 bytes long).
INT16
Result code; 0 means success
Returns:
The return value is zero if the function is successful. Otherwise, it returns a negative value containing
the error code. For the detailed meaning of the error code, please refer to Appendix A.
Example:
// Select a card in range (reader stationID: 1)
// Let’s assume that there were 2 cards in range and you wanted to select
the one
// with serial number ( FFh FFh FFh FFh )
INT16 RetCode;
Page 32 of 44
ACR120S Application Programming InterfaceDocument Title Here
Document
Title Here
Version 3.00
info@acs.com.hk
www.acs.com.hk
UINT8 SID;
UINT8
pSN[3];
BOOL* pHaveTag;
UINT8* pTAG;
UINT8
pResultSN[3];
SID = 1;
pSN[0]=FF;
pSN[1]=FF;
pSN[2]=FF;
pSN[3]=FF;
RetCode = ACR120_MultiTagSelect(rHandle,
pResultSN);
SID,
pSN,
&pHaveTag,
&pTAG,
// Get Serial Number Returned
StrMsg.Format("Card Serial Selected: %X %X %X %X",
pResultSN[0], pResultSN[1],
pResultSN [2], pResultSN [3] );
2.3.1.24. ACR120_TxDataTelegram
Format:
ACR120_DLLAPI INT16 ACR120_DECL
ACR120_TxDataTelegram(
INT16
hReader,
UINT8
stationID,
UINT8
length,
BOOL
bParity,
BOOL
bOddParity,
BOOL
bCRCGen,
BOOL
bCRCCheck,
BOOL
bCryptoInactive,
UINT8
bitFrame,
UINT8*
data,
UINT8*
pRecvLen,
UINT8*
recvData);
Function Description:
This function transfers user specific data frames.
Parameters
Description
hReader
stationID
length
bParity
bOddParity
bCRCGen
bCRCCheck
bCryptoInactive
The handle to our reader returned by ACR120_Open
The station ID of our reader
The length of user specific data frame
TRUE if parity generation is enabled
TRUE if parity is odd; Otherwise it’s even
TRUE if CRC generation for transmission is enabled
TRUE if CRC checking for receiving is enabled
TRUE if Crypto unit is deactivated before transmission start
bitFrame
Bit Framing (number of bits from last byte transmitted)
data
pRecvLen
recvData
Contains the user specific data frame
It returns the length of response data received
Contains the response data received
INT16
Result code; 0 means success
Return Value
Page 33 of 44
ACR120S Application Programming InterfaceDocument Title Here
Document
Title Here
Version 3.00
info@acs.com.hk
www.acs.com.hk
2.3.1.25. ACR120_RequestVersionInfo
Format:
ACR120_DLLAPI INT16 ACR120_DECL
ACR120_RequestVersionInfo(
INT16
hReader,
UINT8
stationID,
UINT8*
pVersionInfoLen,
UINT8*
pVersionInfo);
Function Description:
This function gets the reader’s firmware version information.
Parameters
Description
hReader
The handle to our reader returned by ACR120_Open
pNumID
The number of station ID returned
pVersionInfoLen
It returns the length of the Firmware Version string
PVersionInfo
It returns the Firmware Version string
Return Value
INT16
Result code; 0 means success
2.3.1.26. PICC_InitBlockNumber
Format:
DLLAPI INT16 AC_DECL PICC_InitBlockNumber (INT16 FrameSizeIndex);
Function Description:
This function resets the block number to be used during the ISO 14443 part 4 (T=CL) communication.
This function also sets the frame length of the Card (PICC). By default the frame length is 16 bytes.
The frame length of the card is reported by the ATS in type A and the ATQB in type B cards.
Parameters
Description
Frame Size Index
Return Value
An index to a maximum frame size which the card can
accept
INT16
The actual frame length selected
The argument only accepts the followings:
Frame Size
Index
Frame Length (in
bytes)
0
1
2
3
4
5
6
7
8
otherwise
16
24
32
40
48
64
96
128
256
16
Page 34 of 44
ACR120S Application Programming InterfaceDocument Title Here
Document
Title Here
Version 3.00
info@acs.com.hk
www.acs.com.hk
Returns:
The actual frame length selected will be returned as a confirmation. E.g. if 4 is used as calling
parameter, the value 48 is returned.
Notes:
This function should be called after
ACR120_MultiTagSelect() function.
each
time
with
the
ACR120_Select()
or
It is suggested to execute this function for type A card or the function ACR120_READATQB for type B
card, just after the ACR120_Select operation, then call the PICC_InitBlockNumber according to
the result of the respective functions.
Example:
//=====================================================================
//'Selects a single card and returns the card ID (Serial Number)
//=====================================================================
//Variable Declarations
BYTE ResultSN[11];
BYTE TagType;
BYTE ResultTag;
char SN[100];
UINT8 SID=1;
BYTE DataLength, pData[10], ResponseDataLength, pResponseData[100];
INT16 TimeOut=50, i, CardFrameSize;
char pdata[500];
char *ATS_ATQB;
retcode = ACR120_Select(rHandle, SID, &TagType, &ResultTag, ResultSN);
//'Check if Retcode is Error
if (retcode >=0 )
{
if ((TagType == 4) || (TagType == 5)) {
// Type A cards
memcpy(SN,ResultSN, 7);
} else {
memcpy(SN,ResultSN, ResultTag);
}
// Get the Info Bytes, if it is a type B card
CardFrameSize=0;
pdata[0]='\0';
ResponseDataLength=0;
if (TagType==0x80) {
// Type B Cards
if (ACR120_ReadATQB(rHandle, SID, pResponseData)==0) {
ResponseDataLength=7;
CardFrameSize=pResponseData[10]>>4;
}
} else if (TagType < 0x80 || TagType == 0xff) {
// Type A Cards
if (PICC_RATS(rHandle, SID, 4, &ResponseDataLength,
pResponseData)>=0) {
CardFrameSize=pResponseData[1]&0x0f;
Page 35 of 44
ACR120S Application Programming InterfaceDocument Title Here
Document
Title Here
Version 3.00
info@acs.com.hk
www.acs.com.hk
}
}
PICC_InitBlockNumber(CardFrameSize); // Set communication frame
// size
} else
{
// Card Selection Error handling here
}
2.3.1.27. PICC_Xch_APDU
Format:
DLLAPI INT16 AC_DECL PICC_Xch_APDU (
INT16 rHandle,
UINT8 station_ID,
BOOL typeA,
INT16 *pTransmitLength,
UINT8 *pxData,
INT16 *pReceiveLength,
UINT8 *prData);
Function Description:
This function handles the APDU exchange in T=CL protocol. This routine will handle the Frame
Waiting Time Extension (WTX) and chaining for long messages.
Parameters
rHandle
station_D
typeA
pTransmitLength
pxData
pReceiveLength
prData
Return Value
Description
The handle to our reader returned by ACR120_Open
The station ID of our reader
A Boolean value indicates the card type,
TRUE for type A cards, FALSE for type B cards
A pointer to the location storing the length of the data to transmit, in
bytes
A pointer to the transmit data storage
A pointer to the location storing the length of the data received, in
bytes
A pointer to the receive data storage
INT16
Result code; 0 means success
Returns:
The return value is zero if the function is successful. Otherwise, it returns a negative value containing
the error code. For the detailed meaning of the error code, please refer to Appendix A.
Notes:
1) The function PICC_InitBlockNumber( ) should be called each time between the
ACR120_Select() or ACR120_MultiTagSelect() function and this function.
2) In many cases, the status code SW1 and SW2 are the last 2 bytes of the received data.
Example:
INT16
UINT8
BOOT
INT16
UINT
UINT8
INT16
rHandle;
SID;
typeA;
xLen, rLen;
rData[100];
Cmd[5]={0x94, 0xb2, 0x01, 0x3c, 0x1D};
RetCode;
Page 36 of 44
ACR120S Application Programming InterfaceDocument Title Here
Document
Title Here
Version 3.00
info@acs.com.hk
www.acs.com.hk
xLen=5;
SID=1;
typeA = FALSE;
// Type B card
//Selects a single card and returns the card ID (Serial Number)
retcode = ACR120_Select(rHandle, SID, &HaveTag, &tmpbyte, tmpArray);
if (retcode == 0)
{
// If a card is selected, proceed to issue an APDU of 94B2013C1D
PICC_InitBlockNumber(0);
retcode = PICC_Xch_APDU(rHandle,
rData);
//check if retcode is error
SID,
typeA,
&xLen,
Cmd,
&rLen,
if(retcode < 0){
// Exchange APDU failed
} else{
// Exchange APDU successful
}
}
2.3.1.28. PICC_RATS
Format:
DLLAPI INT16 AC_DECL PICC_RATS (
INT16 rHandle,
UINT8 station_ID,
UINT8 FSDI,
BOOL typeA,
UINT8 *pATSlen,
UINT8
*pATS);
Function Description:
This function is only valid for ISO 14443 type A cards. It requests an Answer-to-Select (ATS)
message from the card after doing the ACR120_Select( ) operation. It tells the card how many
bytes the reader can handle in a frame and also gets the operation parameters of the card when
communicating in ISO 14443 mode.
Parameters
Description
rHandle
station_ID
The handle to our reader returned by ACR120_Open
the station ID of our reader
An index to a maximum frame size which the reader can
accept. The value should not exceed 4, i.e. 48 bytes
A Boolean value indicates the card type. This value should
always be TRUE.
A pointer to the location storing the length of the ATS received
A pointer to the ATS received
INT16
Result code; 0 means success
FSDI
typeA
pATSlen
pATS
Return Value
Page 37 of 44
ACR120S Application Programming InterfaceDocument Title Here
Document
Title Here
Version 3.00
info@acs.com.hk
www.acs.com.hk
The FSDI to (Frame Size for proximity coupling Device) FSD conversion:
FSDI
FSD (in bytes)
0
1
2
3
4
5
6
7
8
otherwise
16
24
32
40
48
64
96
128
256
RFU
Returns:
The return value is zero if the function is successful. Otherwise, it returns a negative value containing
the error code. For the detailed meaning of the error code, please refer to Appendix A. For detailed
meaning of the ATS, please refer to corresponding documents.
Note:
There is no need for calling this function in type B cards.
2.3.1.29.
PICC_Deselect
Format:
DLLAPI INT16 AC_DECL PICC_Deselect(
INT16 rHandle,
UINT8 station_ID,
BOOL typeA);
Function Description:
This function sends DESELECT (card close) signal to the cards running ISO 14443 part 4 (T=CL )
protocol.
Parameters
rHandle
station_ID
typeA
Return Value
Description
The handle to our reader returned by ACR120_Open
the station ID of our reader
A Boolean value indicates the card type,
TRUE for type A cards, FALSE for type B cards
INT16
Result code; 0 means success
Returns:
The return value is zero if the function is successful. Otherwise, it returns a negative value containing
the error code. For the detailed meaning of the error code, please refer to Appendix A.
Page 38 of 44
ACR120S Application Programming InterfaceDocument Title Here
Document
Title Here
Version 3.00
info@acs.com.hk
www.acs.com.hk
2.3.1.30. ACR120_ReadATQB
Format:
DLLAPI INT16 AC_DECL ACR120_ReadATQB(INT16
rHandle,
UINT8 stationID,
UINT8 *pATQB);
Function Description:
This function reads the ATQB data from the card. This function only works after a successful Select
command on an ISO 14443 type B card.
Parameters
Description
rHandle
stationID
pATQB
The handle to ACR120 reader returned by ACR120_Open
The Station ID of ACR120 Reader
A pointer to a 7 byte data array containing the ATQB. The first 4
bytes and last 3 bytes being the Application Data and Protocol
Info respectively.
Returns:
The return value is zero if the function is successful. Otherwise, it returns a negative value containing
the error code. An error will return if the ACR120_Select command is not previously executed with
success on a type B card.
Notes:
This function only works after a successful Select command on an ISO 14443 type B card.
Example:
INT16 RetCode;
UINT8 SID;
UINT8 pSN[4]
UINT8 pATQB[7];
BOOL pHaveTag;
UINT8 pTAG;
SID=1;
// Select a type B card
RetCode = ACR120_Select (rHandle, SID, &pHaveTag, &pTAG, pSN);
RetCode = ACR120_ReadATQB (rHandle, SID, pATQB);
if (RetCode==0) {
StrMsg.Format(“Card ATQB = %02X%02X%02X%02X%02X%02X%02X”,
pATQB[0], pATQB[1], pATQB[2], pATQB[3], pATQB[4],
pATQB[5], pATQB[6]);
}
Page 39 of 44
ACR120S Application Programming InterfaceDocument Title Here
Document
Title Here
Version 3.00
info@acs.com.hk
www.acs.com.hk
2.3.1.31. ACR120_SetFWI
ACR120_SetFWI(
INT16 hReader,
UINT8 stationID,
UINT8 *pFWI)
Function Description:
This function alters the default Frame Waiting Index (FWI) which the ISO 14443 cards reported during
the initial card operation. The value of the reader is adopted through the ACR120_RATS() operation
in type A cards and the ACR120_Select() operation in type B cards. In some instances, the frame
waiting time may need to extend to wait for certain computation intensive operations on the card,
which the card will request for a Waiting Time Extension (WTX) inside the ISO 14443 part 4
communication.
This function is called by the ACR120_Xch_APDU() API and is usually not needed to be called by
high level application explicitly.
Parameters
RHandle
stationID
pFWI
Return Value
Description
The handle to ACR120 reader returned by ACR120_Open
The Station ID of ACR120 Reader.
Contains the new FWI to be set (value <= 0x0e)
INT16
Result code. 0 means success.
Returns:
The return value is zero if the function is successful. Otherwise, it returns a negative value containing
the error code. For the detailed meaning of the error code, please refer to appendix A. The new FWI
value is updated by the function.
Note: According to the ISO 14443 part 4 specifications, the maximum value of FWI is 0x0E.
The FWI value will be updated by the maximum value the card reader that can support.
The actual waiting time FWT is calculated by the following formula:
FWT = (256 * 16 / 13560000) * (2 ^ FWI)
which gives 4.94s if FWI = 14
Page 40 of 44
ACR120S Application Programming InterfaceDocument Title Here
Document
Title Here
Version 3.00
info@acs.com.hk
www.acs.com.hk
2.3.1.32. ACR120_FlipUserPort
Format:
DLLAPI INT16 AC_DECL ACR120_FlipUserPort(INT16 rHandle,
UINT8 stationID,
UINT8 PortFlipAction);
Function Description:
This function is added to ease the LED/Relay flipping and Buzzer sounding operation. The
ACR120_WriteUserPort only turns ON or OFF of the corresponding devices according to the
argument userPortState (c.f. ACR120_WRITEUSERPORT function), it could be difficult for the
controlling PC program to time the activation duration precisely. This function call activates the
LED/Relay and Buzzer for a precise duration defined in EEPROM values in address 0x07 and 0x08
respectively. This function will not take any action when called if the value is zero (0x00) in the
respective EEPROM locations.
Parameters
RHandle
stationID
userPortState
Return Value
Description
The handle to ACR120 reader returned by ACR120_Open
The Station ID of ACR120 Reader
Value
Action
0x00
No action
0x01
Turns on LED/Relay on for m
milliseconds
0x02
Turns on Buzzer on for m
milliseconds
0x03
Turns on LED/Relay and Buzzer on
for the respective durations
INT16
Result code; 0 means success
m = 200 ms x (the value in EEPROM location 0x07)
n = 200 ms x (the value in EEPROM location 0x08)
Returns:
The return value is always zero indicates a successful execution.
Page 41 of 44
ACR120S Application Programming InterfaceDocument Title Here
Document
Title Here
Version 3.00
info@acs.com.hk
www.acs.com.hk
Appendix A. Table of Error Codes
Code
Meaning
ERR_ACR120_INTERNAL_UNEXPECTED(1000)
Library internal
unexpected error
ERR_ACR120_PORT_INVALID(2000)
The port is invalid
ERR_ACR120_PORT_OCCUPIED(2010)
The port is occupied by
another application
ERR_ACR120_HANDLE_INVALID(2020)
The handle is invalid
ERR_ACR120_INCORRECT_PARAM(2030)
Incorrect Parameter
ERR_ACR120_READER_NO_TAG(3000)
ERR_ACR120_READER_READ_FAIL_AFTER_OP(3010)
ERR_ACR120_READER_NO_VALUE_BLOCK(3020)
No TAG in reachable
range / selected
Read fail after
operation
Block doesn’t contain
value
ERR_ACR120_READER_OP_FAILURE(3030)
Operation failed
ERR_ACR120_READER_UNKNOWN(3040)
Reader unknown error
ERR_ACR120_READER_LOGIN_INVALID_STORED_KEY_FORMAT(4010)
ERR_ACR120_READER_WRITE_READ_AFTER_WRITE_ERROR(4020)
ERR_ACR120_READER_DEC_FAILURE_EMPTY(4030)
Invalid stored key
format in login process
Reader can’t read after
write operation
Decrement failure
(empty)
Page 42 of 44
ACR120S Application Programming InterfaceDocument Title Here
Document
Title Here
Version 3.00
info@acs.com.hk
www.acs.com.hk
Appendix B. Sector Number Adaptation on Mifare
4K Card
Sector Number
on Card
0x00
0x01
0x02
0x03
0x04
0x05
0x06
0x07
0x08
0x09
0x0A
0x0B
0x0C
0x0D
0x0E
0x0F
0x10
0x11
0x12
0x13
0x14
0x15
0x16
0x17
0x18
0x19
0x1A
0x1B
0x1C
0x1D
0x1E
0x1F
0x20
0x21
0x22
0x23
0x24
0x25
0x26
0x27
Sector Number for
Log-in
0x00
0x01
0x02
0x03
0x04
0x05
0x06
0x07
0x08
0x09
0x0A
0x0B
0x0C
0x0D
0x0E
0x0F
0x10
0x11
0x12
0x13
0x14
0x15
0x16
0x17
0x18
0x19
0x1A
0x1B
0x1C
0x1D
0x1E
0x1F
0x20
0x24
0x28
0x2C
0x30
0x34
0x38
0x3C
Block Number
0x00-0x03
0x04-0x07
0x08-0x0B
0x0C-0x0F
0x10-0x13
0x14-0x17
0x18-0x1B
0x1C-0x1F
0x20-0x23
0x24-0x27
0x28-0x2B
0x2C-0x2F
0x30-0x33
0x34-0x37
0x38-0x3B
0x3C-0x3F
0x40-0x43
0x44-0x47
0x48-0x4B
0x4C-0x4F
0x50-0x53
0x54-0x57
0x58-0x5B
0x5C-0x5F
0x60-0x63
0x64-0x67
0x68-0x6B
0x6C-0x6F
0x70-0x73
0x74-0x77
0x78-0x7B
0x7C-0x7F
0x80-0x8F
0x90-0x9F
0xA0-0xAF
0xB0-0xBF
0xC0-0xCF
0xD0-0xDF
0xE0-0xEF
0xF0-0xFF
Card Type
Mifare 1K
Mifare 4K
Standard
sectors
Standard
sectors
Big sectors
Page 43 of 44
ACR120S Application Programming InterfaceDocument Title Here
Document
Title Here
Version 3.00
info@acs.com.hk
www.acs.com.hk
Appendix C. Physical and Logical Block/Sector
Calculation
Appendix C.1. Mifare 1K



Logical Sector is equal to Physical sector, which are 0 to 15.
Logical block of each sector is from 0 to 3.
Physical blocks = ((Sector * 4) + Logical block )
Appendix C.2. Mifare 4K

Case 1: If { 0 <= Logical Sector <= 31}
o Physical sector is equal to Logical.
o Logical block of each sector is from 0 to 3.
o Physical blocks = ((Sector * 4) + Logical block)

Case 2: If { 32 <= Logical Sector <= 39}
o
Physical Sector = Logical Sector + (( Logical Sector - 32) * 3)
o
Logical block of each sector is from 0 to 15.
o
Physical blocks = ((Logical Sector - 32) * 16) + 128 + Logical block
Page 44 of 44
ACR120S Application Programming InterfaceDocument Title Here
Document
Title Here
Version 3.00
info@acs.com.hk
www.acs.com.hk
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF