DMV Series 50-250W For Combustible Dusts Champ H.I.D. Luminaires

DMV Series 50-250W For Combustible Dusts Champ H.I.D. Luminaires
DMV Series 50-250W
For Combustible Dusts
3L
Champ® H.I.D. Luminaires
Cl. II, Groups E, F, G; Cl. III &
Simultaneous Presence
(175W max)
Marine & Wet Locations
3, 3R, 4, 4X; IP66
Applications:
Options:
DMV series Champ luminaires are used:
The following special options are available
from the factory by adding suffix to luminaire
Cat. No.:
• In applications made hazardous by the
presence of combustible dusts
• In areas in which ignitible concentrations of
flammable gases or vapors will be present
only due to abnormal, unusual, or accidental
conditions
• In marine applications where water spray
and corrosive atmospheres are
considerations
• In areas where combustible dusts and
flammable vapors are present
simultaneously
• In elevated ambient temperatures often
found in industrial applications
• In installations where moisture, dirt, dust,
vibration, corrosion and rough usage are
problems
• Wherever the damaging effects of wind,
snow, sleet, or hot sun are found
• In grain handling, storage and processing
plants, coal preparation plants, coal
conveying areas, food processing plants,
manufacturing plants, refineries, chemical,
petrochemical, and other industrial process
facilities, waste or sewage treatment
facilities, offshore, dockside, and harbor
installations, and other heavy industrial
applications
Features:
3L
Cl. I, Div. 2, Groups A, B, C, D
Restricted Breathing Cl. I, Div. 2
& Zone 2 (Suffix S826)
Certified for IEC Zone 2
(Suffix S826TB)
• Cast copper-free aluminum construction
(less than 0.4 of 1% copper) and epoxy
powder finish provide excellent resistance
to corrosion.
• Seven mounting arrangements to suit any
lighting layout – pendant, flexible pendant,
ceiling, wall bracket, angle stanchion,
straight stanchion, and quad-mount.
• Wide range of light sources and wattages
to meet specifiers' needs: 50, 70, 100, 150
watt high pressure sodium (HPS); 70, 100,
175, 250 watt metal halide.
• Hinged ballast housing for ease of
installation and maintenance.
• All luminaires designed to perform in a 40°C
ambient temperature. Selected luminaires
are suitable for ambient temperatures up to
65°C.
• Superior gasketing seals between the
mounting module, housing, and optical
assembly for optimum performance in wet
and corrosive environments.
• Hubs with an integral conduit stop and
bushing to help prevent damage to field
wiring during installation.
• Low ambient capability to (–40°C.)
• Dome and 30° angle reflectors made of
bright white Krydon® material provide
superior reflectivity, with twist-on feature
requiring no tools or additional hardware.
Will not chip, peel, dent, rust, or corrode.
• Mogul base porcelain lamp socket.
• Stainless steel open bottom guard permits
direct access to the globe for easy
relamping.
www.crouse-hinds.com
US: 1-866-764-5454
Description
• Grounding wire for safety.
• Ballasts available in voltages of 120, 208,
240, 277, 347, 480, 600 and multi-tap.*
Certifications and
Compliances:
• NEC/CEC:
Class I, Division 2, Groups A, B, C, D
175W max – Class II, Class III &
Simultaneous Presence (Class I, Division 2
and Class II)
Class I, Zone 2
• IEC:
Zone 2 Ex nR IIC
• UL Standards:
844 Hazardous (Classified) Locations
1598 Luminaires
1598A Marine Locations
• CSA Standards:
C22.2 No. 137
• IEC Standards:
60079-15
Standard Materials:
• Ballast housings and mountings – copperfree aluminum (less than 0.4 of 1% copper)
• Guard and exterior hardware – stainless
steel
• Reflectors (dome and angle) – Krydon
fiberglass-reinforced polyester material
• Globes – heat and impact resistant,
internally fluted glass
Suffix
• Restricted Breathing Construction . . . S826
Class I, Division 2 & Zone 2
Suitabilty
Cooler Operating Temperatures
(T-Numbers)
• Restricted Breathing/Non-Sparking . . S865
Class I, Division 2 & Zone 2
Provides T3 code without conduit
or cable seals
• Certified for IEC Zone 2 . . . . . . . . . . S826TB
Furnished with terminal block,
crimp terminals and dedicated
voltage ballasts (no MT, DT or TT)
• Fused – to protect ballast and
capacitors against abnormal line
conditions . . . . . . . . . . . . . . . . . . . . . S658*
(Not available with /MT Ballast)
(Not for use in Canada)
(Not suitable for marine applications)
• Quick-Clip - Holds weight of housing
when closed. No need to support
luminaire while screwing the housing
to the cover . . . . . . . . . . . . . . . . . . . S890
• Ballast-Gard™ starter cut-out switch
– prevents starter pulsing when lamp
is cycling or inoperative; prolongs
ballast and ignitor life. Available for
use with 50–150W LX HPS only . . . .
BG
• Instant restrike – enables a hot HPS
lamp to immediately restrike after a
momentary loss of arc due to
voltage fluctuation or power outage.
It has no effect on the warm-up
period of cold lamps.
50–150W LX HPS only . . . . . . . . . IR
• Quartz auxiliary lighting – comes
to full brightness immediately and
remains lit until the HID lamp attains
60–70% of full illumination. For
non-hazardous locations only. (Note:
QTZ lamp not included; use 100W
single ended lamp – Q100DC,
Q100CL/DC, or 100Q/CL/DC)
Consult factory for top-hat
limitations . . . . . . . . . . . . . . . . . . . . . QTZ
• Factory assembled with H.I.D. lamps
installed for additional labor savings
FA
• TEFLON® coated globe for additional
protection against breakage. For use
with 50–150W HPS and 70–175W
MH (G303 only) . . . . . . . . . . . . . . . . . S808
Standard Finishes:
Note: Some T-numbers (operating temperatures) change.
See "Temperature Performance Data" section.
• Copper-free aluminum – epoxy powder
coat
• Krydon material – high reflectance white
• Stainless steel – natural
• Stainless steel insert – top hat with
stainless steel threaded insert to
attach ballast housing . . . . . . . . . . . S806
Electrical Ratings:
Accessories:
• 120, multi-tap* (120, 208, 240 and 277),
tri-tap (120, 277, 347) 480, 600 volts
• 50–250W HPS; 70–250W MH
• See pages 1022–1023 for complete listing.
CAN: 1-800-265-0502
Note: BG and IR options cannot be used together. IR and
QTZ options cannot be used together.
TEFLON is a registered trademark of E.I. duPont Co.
*When ordering fuses for luminaires, option S658, you
must specify the operating voltage. S658 cannot be
ordered with /MT in the catalog number.
Copyright© 2015 Eaton’s Crouse-Hinds Business
DMV Series 50-150W
High Pressure Sodium
For Combustible Dust Applications
Champ® H.I.D. Luminaires
Cl. I, Div. 2, Groups A, B, C, D
Restricted Breathing Cl. I, Div. 2
& Zone 2 (Suffix S826)
Certified for IEC Zone 2 (Suffix
S826TB)
Cl. II, Groups E, F, G; Cl. III
& Simultaneous Presence
Marine & Wet Locations
3, 3R, 4, 4X; IP66
3L
To complete the catalog #, include information in notes 1, 2 and 3 below. For guards and other optics see DMV Series - Ordering By Components page.
BASIC CATALOG NUMBER
Mounting
Hub
Lamp
With G303 Globe
With GR305 Glass
Style
Size
Watts
and P33 Guard
Refractor *
Pendant Mount
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
3
/4
3
/4
3
/4
50
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
3
/4
3
/4
3
/4
50
Stanchion Mount
25° Angle
Stanchion Mount
Straight
Flexible Pendant
Mount
Ceiling Mount
Thru-Feed
Wall Mount
Thru-Feed
Quad-Mount
Pendant,
Adjustable Thru-Feed,
25° Angle, 121/ 2° Angle
DMVS2A050GP
DMVS3A050GP
DMVS2A070GP
DMVS3A070GP
DMVS2A100GP
DMVS3A100GP
DMVS2A150GP
DMVS3A150GP
DMVS2HA050GP
DMVS2HA070GP
DMVS2HA100GP
DMVS2HA150GP
DMVS2A050GR305
DMVS3A050GR305
DMVS2A070GR305
DMVS3A070GR305
DMVS2A100GR305
DMVS3A100GR305
DMVS2A150GR305
DMVS3A150GR305
DMVS2HA050GR305
DMVS2HA070GR305
DMVS2HA100GR305
DMVS2HA150GR305
50
70
100
150
DMVS2C050GP
DMVS3C050GP
DMVS2C070GP
DMVS3C070GP
DMVS2C100GP
DMVS3C100GP
DMVS2C150GP
DMVS3C150GP
DMVS2TW050GP
DMVS3TW050GP
DMVS2TW070GP
DMVS3TW070GP
DMVS2TW100GP
DMVS3TW100GP
DMVS2TW150GP
DMVS3TW150GP
DMVS25Q050GP
DMVS25Q070GP
DMVS25Q100GP
DMVS25Q150GP
DMVS2C050GR305
DMVS3C050GR305
DMVS2C070GR305
DMVS3C070GR305
DMVS2C100GR305
DMVS3C100GR305
DMVS2C150GR305
DMVS3C150GR305
DMVS2TW050GR305
DMVS3TW050GR305
DMVS2TW070GR305
DMVS3TW070GR305
DMVS2TW100GR305
DMVS3TW100GR305
DMVS2TW150GR305
DMVS3TW150GR305
DMVS25Q050GR305
DMVS25Q070GR305
DMVS25Q100GR305
DMVS25Q150GR305
11/2
11/2
11/2
11/2
50
70
100
150
DMVSJ050GP
DMVSJ070GP
DMVSJ100GP
DMVSJ150GP
DMVSJ050GR305
DMVSJ070GR305
DMVSJ100GR305
DMVSJ150GR305
11/2
11/2
11/2
11/2
50
70
100
150
DMVSP050GP
DMVSP070GP
DMVSP100GP
DMVSP150GP
DMVSP050GR305
DMVSP070GR305
DMVSP100GR305
DMVSP150GR305
70
100
150
50
70
100
150
70
100
150
50
70
100
150
3L
* For GR302 Type II Refractor, change "GR305" at end of catalog number to "GR302". Ex. DMVS2A050GR302
For GR303 Type III Refractor, change "GR305" at end of catalog number to "GR303". Ex. DMVS2A050GR303
2. 150W HPS Luminaires: For 55V lamps - add suffix LX;
for 100V lamps - add suffix CE. 50W HPS luminaire
is dual tap only.
1. Add voltage suffix to end of catalog number
Standard Voltage Ballasts – 60Hz
NEC/UL
Voltage
Suffix
Multi Tap
/MT
Dual Tap
/DT
CEC/CSA (cUL)
120V
/120
480V
/480
Tri Tap
/TT
Dual Tap
/DT
600V CWI
/600CWI
220V 60Hz
/220
220V 50Hz
/220 50
Optional Voltage Ballasts - 50 or 60Hz
CEC/CSA (cUL) - CWI Isolated Ballasts
Voltage
Suffix
208V CWI
/208CWI
240V CWI
/240CWI
480V CWI
/480CWI
www.crouse-hinds.com
120V
/120
3. Options - Add the required option suffixes,
see page 980, in alpha-numeric order.
EXPORT
US: 1-866-764-5454
230V 50Hz
/230 50
240V 50Hz
/240 50
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
981
3L DMV Series - 150-250W
Pulse Start Metal Halide
Cl. I, Div. 2, Groups A, B, C, D
Restricted Breathing Cl. I, Div. 2
& Zone 2 (Suffix S826)
Certified for IEC Zone 2
(Suffix S826TB)
For Combustible Dust Applications
Champ® H.I.D. Luminaires
Cl. II, Groups E, F, G; Cl. III &
Simultaneous Presence
(175W max)
Marine & Wet Locations
3, 3R, 4, 4X; IP66
To complete the catalog #, include information in notes 1 and 2 below. For guards and other optics see DMV Series - Ordering By Components page.
Mounting
Style
Lamp
Watts
With G303 Globe
and P33 Guard
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
3
/4
3
/4
3
/4
150
DMVM2A150GP S828
DMVM3A150GP S828
DMVM2A175GP S828
DMVM3A175GP S828
DMVM2A200GP S828
DMVM3A200GP S828
DMVM2A250GP S828
DMVM3A250GP S828
DMVM2HA150GP S828
DMVM2HA175GP S828
DMVM2HA200GP S828
DMVM2HA250GP S828
DMVM2A150GR305 S828
DMVM3A150GR305 S828
DMVM2A175GR305 S828
DMVM3A175GR305 S828
DMVM2A200GR305 S828
DMVM3A200GR305 S828
DMVM2A250GR305 S828
DMVM3A250GR305 S828
DMVM2HA150GR305 S828
DMVM2HA175GR305 S828
DMVM2HA200GR305 S828
DMVM2HA250GR305 S828
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
3
/4
3
/4
3
/4
150
150
175
200
250
DMVM2C150GP S828
DMVM3C150GP S828
DMVM2C175GP S828
DMVM3C175GP S828
DMVM2C200GP S828
DMVM3C200GP S828
DMVM2C250GP S828
DMVM3C250GP S828
DMVM2TW150GP S828
DMVM3TW150GP S828
DMVM2TW175GP S828
DMVM3TW175GP S828
DMVM2TW200GP S828
DMVM3TW200GP S828
DMVM2TW250GP S828
DMVM3TW250GP S828
DMVM25Q150GP S828
DMVM25Q175GP S828
DMVM25Q200GP S828
DMVM25Q250GP S828
DMVM2C150GR305 S828
DMVM3C150GR305 S828
DMVM2C175GR305 S828
DMVM3C175GR305 S828
DMVM2C200GR305 S828
DMVM3C200GR305 S828
DMVM2C250GR305 S828
DMVM3C250GR305 S828
DMVM2TW150GR305 S828
DMVM3TW150GR305 S828
DMVM2TW175GR305 S828
DMVM3TW175GR305 S828
DMVM2TW200GR305 S828
DMVM3TW200GR305 S828
DMVM2TW250GR305 S828
DMVM3TW250GR305 S828
DMVM25Q150GR305 S828
DMVM25Q175GR305 S828
DMVM25Q200GR305 S828
DMVM25Q250GR305 S828
Stanchion Mount
25° Angle
11/2
11/2
11/2
11/2
150
175
200
250
DMVMJ150GP
DMVMJ175GP
DMVMJ200GP
DMVMJ250GP
S828
S828
S828
S828
DMVMJ150GR305
DMVMJ175GR305
DMVMJ200GR305
DMVMJ250GR305
S828
S828
S828
S828
Stanchion Mount
Straight
11/2
11/2
11/2
11/2
150
175
200
250
DMVMP150GP
DMVMP175GP
DMVMP200GP
DMVMP250GP
S828
S828
S828
S828
DMVMP150GR305
DMVMP175GR305
DMVMP200GR305
DMVMP250GR305
S828
S828
S828
S828
Pendant Mount
Flexible
Pendant
Mount
Ceiling Mount
Thru-Feed
Wall Mount
Thru-Feed
Quad-Mount
Pendant, Adjustable
Thru-Feed, 25° Angle,
121/ 2° Angle
3L
BASIC CATALOG NUMBER
With GR305 Glass
Refractor *
Hub
Size
175
200
250
150
175
200
250
175
200
250
150
175
200
250
* For GR302 Type II Refractor, change "GR305" at end of catalog number to "GR302". Ex. DMVM2A150GR302-S828
For GR303 Type III Refractor, change "GR305" at end of catalog number to "GR303". Ex. DMVM2A150GR303-S828
1. Add voltage suffix to end of catalog number
Standard Voltage Ballasts – 60Hz
NEC/UL
Voltage
Suffix
Multi Tap
/MT
CEC/CSA (cUL)
120V
/120
480V
/480
Tri Tap
/TT
230V 50Hz
/230 50
240V 50Hz
/240 50
120V
/120
Optional Voltage Ballasts - 50 or 60Hz
EXPORT
Voltage
Suffix
220V 60Hz
/220
220V 50Hz
/220 50
2. Options - Add the required option suffixes, see page 980, in alpha-numeric order.
982
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
DMV Series 70–250W
Metal Halide
Cl. I, Div. 2, Groups A, B, C, D
Restricted Breathing Cl. I, Div. 2
& Zone 2 (Suffix S826)
Certified for IEC Zone 2
(Suffix S826TB)
For Combustible Dust Applications
Champ® H.I.D. Luminaires
Cl. II, Groups E, F, G; Cl. III &
Simultaneous Presence
(175W max)
Marine & Wet Locations
3, 3R, 4, 4X; IP66
3L
To complete the catalog #, include information in notes 1, 2 and 3 below. For guards and other optics see DMV Series - Ordering By Components page.
BASIC CATALOG NUMBER
With GR305 Glass
Refractor *
Mounting
Style
Hub
Size
Lamp
Watts
With G303 Globe
and P33 Guard
Pendant Mount
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
3
/4
3
/4
3
/4
70
DMVM2A070GP
DMVM3A070GP
DMVM2A100GP
DMVM3A100GP
DMVM2A175GP
DMVM3A175GP
DMVM2A250GP
DMVM3A250GP
DMVM2HA070GP
DMVM2HA100GP
DMVM2HA175GP
DMVM2HA250GP
DMVM2A070GR305
DMVM3A070GR305
DMVM2A100GR305
DMVM3A100GR305
DMVM2A175GR305
DMVM3A175GR305
DMVM2A250GR305
DMVM3A250GR305
DMVM2HA070GR305
DMVM2HA100GR305
DMVM2HA175GR305
DMVM2HA250GR305
3
/4
1
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
1
3
/4
3
/4
3
/4
3
/4
70
3
100
70
100
175
250
DMVM2C070GP
DMVM3C070GP
DMVM2C100GP
DMVM3C100GP
DMVM2C175GP
DMVM3C175GP
DMVM2C250GP
DMVM3C250GP
DMVM2TW070GP
DMVM3TW070GP
DMVM2TW100GP
DMVM3TW100GP
DMVM2TW175GP
DMVM3TW175GP
DMVM2TW250GP
DMVM3TW250GP
DMVM25Q070GP
DMVM25Q100GP
DMVM25Q175GP
DMVM25Q250GP
DMVM2C070GR305
DMVM3C070GR305
DMVM2C100GR305
DMVM3C100GR305
DMVM2C175GR305
DMVM3C175GR305
DMVM2C250GR305
DMVM3C250GR305
DMVM2TW070GR305
DMVM3TW070GR305
DMVM2TW100GR305
DMVM3TW100GR305
DMVM2TW175GR305
DMVM3TW175GR305
DMVM2TW250GR305
DMVM3TW250GR305
DMVM25Q070GR305
DMVM25Q100GR305
DMVM25Q175GR305
DMVM25Q250GR305
Stanchion Mount
25° Angle
11/2
11/2
11/2
11/2
70
100
175
250
DMVMJ070GP
DMVMJ100GP
DMVMJ175GP
DMVMJ250GP
DMVMJ070GR305
DMVMJ100GR305
DMVMJ175GR305
DMVMJ250GR305
Stanchion Mount
Straight
11/2
11/2
11/2
11/2
70
100
175
250
DMVMP070GP
DMVMP100GP
DMVMP175GP
DMVMP250GP
DMVMP070GR305
DMVMP100GR305
DMVMP175GR305
DMVMP250GR305
Flexible
Pendant
Mount
Ceiling Mount
Thru-Feed
Wall Mount
Thru-Feed
Quad-Mount
Pendant, Adjustable
Thru-Feed, 25° Angle,
121/2° Angle
100
175
250
70
100
175
250
175
250
70
100
175
250
3L
* For GR302 Type II Refractor, change "GR305" at end of catalog number to "GR302". Ex. DMVM2A070GR302
For GR303 Type III Refractor, change "GR305" at end of catalog number to "GR303". Ex. DMVM2A070GR303
1. Add voltage suffix to end of catalog number
Standard Voltage Ballasts – 60Hz
NEC/UL
Voltage
Suffix
Multi Tap
/MT
120V
/120
CEC/CSA (cUL)
480V
/480
Tri Tap
/TT
120V
/120
220V 60Hz
/220
220V 50Hz
/220 50
Optional Voltage Ballasts - 50 or 60Hz
CEC/CSA (cUL) - CWI Isolated Ballasts - 175W and 250W MH only
Voltage
Suffix
208V CWI
/208CWI
240V CWI
/240CWI
600V CWI
/600CWI
EXPORT
230V 50Hz
/230 50
240V 50Hz
/240 50
2. 70W ballast not available in 480V.
3. Options - Add the required option suffixes, see page 980, in alpha-numeric order.
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
983
DMV Series –
Ordering by Components
3L
DMV luminaires are available in components.
A complete luminaire consists of:
I.
Champ Cover (Mounting Module)
II.
DMV Ballast Housing – Include voltage and required option(s)
III.
Globe, Refractor, Guard, Reflector
I. Champ Cover (Mounting Module):
Type
Pendant
Conduit
Cat. #
/4"
1"
APM2
APM3
Flexible Pendant
3
/4"
HPM2
Ceiling*
3
/4"
1"
CM2
CM3
Wall
3
/4"
1"
TWM2
TWM3
Stanchion – 25 Degree Angle
11/2"
JM5
Stanchion – Straight
11/2"
PM5
Quad-Mount
3
/4"
QM25
3
*Not available with V2PC photocell.
II. Ballast Housings:
Complete catalog number must have the voltage suffix (MT shown) and any options suffixes.
Lamp Watts
Cat. #
50
70
100
150
DMVS050/MT
DMVS070/MT
DMVS100/MT
DMVS150/MT LX
Metal Halide
70
100
175
250
DMVM070/MT
DMVM100/MT
DMVM175/MT
DMVM250/MT
3L
Lamp Type
High Pressure Sodium
III. Globe, Reflectors, Refractors, Guards:
Type
Cat. #
Globe
G303
Globe – Teflon Coated
G303S808
Globe Guard
P33
Reflector – Dome
RD739
Reflector – Angle
RA739
Refractor – Type 2
GR302
Refractor – Type 3
Refractor – Type 5
GR303
Large Plastic Refractor Type 2
PGR302
Large Plastic Refractor Type 3
PGR303
Large Plastic Refractor Type 5
PGR305
Refractor Guard
P23
High Bay Reflector/Lens
GRD4
www.crouse-hinds.com
GR305
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2015 Eaton’s Crouse-Hinds Business
DMV Series
3L
Family Tree
Champ® H.I.D. Luminaires
3L
*Plastic refractors are non-hazardous areas only (50-100W Max.)
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
985
3L
DMV Series
Temperature Performance Data
Champ® H.I.D. Luminaires
Rated
Ambient
°C
Lamp
Class II, Division 1
Class I, Zone 2
Cat. #
DMVS50
DMVS50
DMVS50
DMVS70
DMVS70
DMVS70
DMVS100
DMVS100
DMVS100
DMVS150
DMVS150
DMVS150
Wattage
50
50
50
70
70
70
100
100
100
150
150
150
Type
HPS
HPS
HPS
HPS
HPS
HPS
HPS
HPS
HPS
HPS
HPS
HPS
40
55
65
40
55
65
40
55
65
40
55
65
DMVM70
DMVM70
DMVM70
DMVM100
DMVM100
DMVM100
DMVM150
DMVM150
DMVM150
DMVM175
DMVM175
DMVM175
DMVM175
DMVM175
DMVM175
DMVM200
DMVM200
DMVM250
DMVM250
70
70
70
100
100
100
150
150
150
175
175
175
175
175
175
200
200
250
250
MH
MH
MH
MH
MH
MH
MH PS
MH PS
MH PS
MH
MH
MH
MH PS
MH PS
MH PS
MH
MH
MH
MH
40
55
65
40
55
65
40
55
65
40
55
65
40
55
65
40
55
40
55
T3C*
T3B*
T3A*
T3*
T3*
T2D*
T2B
T2A
T2A
T2B*
T2A*
T2A*
T2B*
T2A*
T2A*
T2
T1 (325)
T2
T1 (325)
T3C
T3C
T3A
T3A
T3A
T2D
—
—
—
T2
T2
T2
—
—
—
—
—
—
—
T3C
—
—
T3C
—
—
T4A
T4
T4
T3C
—
—
T4A
T4
T4
—
—
—
—
—
—
—
—
—
—
T4A
T4
T4
T3C
—
—
T4A
T4
T4
—
—
—
—
—
—
—
—
—
—
—
—
—
T2A
—
—
—
—
—
—
—
—
—
T6
T5
T5
T5
T5
T4
T4
T4
T4
T4
T4
T3
T4
T4
T4
T4
T3
T4
T3
T6
T5
T5
T5
T5
T4
T4
T4
T4
T4
T4
T3
T4
T4
T4
T4
T3
T4
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
T3
90
90
90
90
90
90
105
105
105
90
90
90
105
105
105
90
90
90
90
2 / 26 (52)
2 / 32 (64)
2 / 42 (84)
CF
CF
CF
40
40
40
T3
T3
T3A
—
—
—
T6
T6
T4A
—
T6
T4A
—
—
—
T6
T6
T4
T6
T6
T4
T3
T3
—
90
90
90
85
85
165
Induction
Induction
Induction
40
55
40
T3
T2D
T3
T3
T2D
—
T5
T4A
T2D
T5
T4A
—
—
—
T2D
T6
T5
T5
T6
T5
—
T5
T4
—
90
90
90
DMVF52
DMVF64
DMVF84
3L
Class I, Division 2
Globe
(G303)
w/ or w/o
Reflector
(RA739 or
RD739)*
T3A
T3
T3
T3A
T3
T3
T2D
T2C
T2C
T2B
T2B
T2A
DMVIG85
DMVIG85
DMVIG165
Refractor
(GR302 or
GR303 or
GR305)
T3A
T3
T3
T3A
T3
T3
T2D
T2C
T2C
T2B
T2B
T2B
Refractor
(G302 or
G303 or
G305) or
Globe
(G303)†
T6
T5
T4A
T6
T5
T4A
T5
T4A
—
T3C
—
—
Globe
(G303)
with
Reflector
(RA739 or
RD739)
T6
T5
T4A
T6
T5
T4A
T5
T4A
—
T3C
—
—
Simultaneous
Presence
Class I, Div. 2
Class II, Div. 1
(with G303
Globe only)
T3A
T3
T3
T3A
T3
T3
T3D
T2C
—
T2A
—
—
Restricted
Breathing
Suffix
S826 w/
Globe
(G303)
T6
T5
T5
T6
T5
T5
T6
T5
T4
T5
T4
—
Globe
(G303)
Factory
with
Sealed
Supply
Reflector
Suffix
Wire
(RA739 or S865 AEx Suitable
RD739)
nA nR II
for °C
T6
T3
90
T5
T3
90
T5
T3
90
T6
T3
90
T5
T3
90
T5
T3
90
T6
T3
90
T5
T3
90
T4
T3
90
T5
T3
90
T4
T3
90
—
T3
90
The Class I, Division 2 T-codes apply to luminaires without the restricted breathing (S826) or factory sealed (S865) options. These luminaires
are listed to UL 844. UL 844 specifies how the temperatures are measured.
The Class I, Zone 2 T-codes are for luminaires that are additionally listed to UL 60079-15 that specify a different method for measuring
temperatures. Since NEC® 501.1 states that equipment "...for use in Class I, Zone 0, 1, or 2 locations shall be permitted in Class I, Division 2
locations..." then these luminaires are suitable for Class I, Division 2 but with lower temperature ratings. They also have the advantage of
meeting the more rigorous mechanical tests of UL 844.
*All DMVM 175W and below MH luminaires provided with Catalog number G303-S808 have a T2A T-code.
†For use with refractor only when this table indicates by means of a T-code that the refractor is suitable for use with Class I, Division 2 luminaires.
986
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
Dimensions & Weights
DMV Series
3L
Champ® H.I.D. Luminaires
Net Luminaire Weights (lbs.):
Dimensions
In Inches:
Pendant Mount
Quad-Mount
Luminaire
Series
Lamp
Watts
Luminaire with
Globe, Guard
(lbs.)
Lamp
Watts
Luminaire with
Globe, Guard
(lbs.)
DMVS
50
100
23
241/16
70
150
231/16
261/8
DMVM
70
175
21
221/4
100
250
211/16
24
Type
Lbs.
Add for mounting modules:
Pendant
11/4
Ceiling
23/4
Quad Mount
31/2
Straight Stanchion
41/2
Type
Lbs.
Flexible Pendant
Wall
Angle Stanchion
11/2
41/2
31/2
Add for reflectors:
30° Angle
Dome
11/4
Deduct: 1 lb. for luminaire without P33 Guard.
Add: 51/2 lbs. for luminaire with GR305 refractor.
25° Angle
Stanchion Mount
Straight Stanchion Mount
Top View
Ceiling Mount
13/4
3L
Wall Mount
Luminaire with Globe, Guard, Reflectors
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Copyright© 2013 Eaton’s Crouse-Hinds Business
987
Photometric Data
DMV Series
3L
Champ® H.I.D. Luminaires
Lamp: 150W/E–23-1/2 clear high pressure sodium (HPS)
Total bare lamp lumens: 16000
NOTE: All data provided is for high pressure sodium luminaires with 150W/E–23-1/2 clear lamps. Use conversion factors (multipliers) shown below for other clear lamp types and wattages.
Consult Eaton's Crouse-Hinds for additional photometric data on any Champ series luminaires.
Luminaire with Globe and Dome Reflector
Multipliers (for use with candela
curve only).
ConLuminaire Lamp
version
Series
Watts Factor
50
70
100
DMVS
Isofootcandle Chart: Luminaire with Globe and
Dome Reflector
0.25
0.40
0.59
Luminaire spacing ratio: 1.90
Coefficient of Utilization
Effective Floor Cavity Reflectance 20%
3L
% Reflectance
Eff. Ceil.
Wall
Room Cavity Ratio
1
2
3
4
5
80
50
30
10
.759
.719
.683
.643
.582
.530
.551
.480
.424
.476
.400
.342
.418
.340
.283
70
50
30
10
.740
.703
.669
.627
.570
.523
.538
.471
.418
.465
.394
.338
.406
.334
.280
50
50
30
10
.703
.672
.645
.595
.548
.506
.512
.455
.408
.442
.381
.332
.388
.324
.276
30
50
30
10
.669
.646
.622
.567
.528
.492
.488
.439
.399
.422
.368
.325
.370
.314
.270
10
50
30
10
.640
.619
.600
.541
.508
.479
.466
.424
.389
.403
.356
.318
.354
.305
.265
0
0
.582
.459
.370
.299
.247
Room Cavity Ratio
6
7
8
9
10
80
50
30
10
.371
.296
.243
.330
.257
.208
.294
.224
.174
.267
.198
.151
.231
.164
.121
70
50
30
10
.362
.291
.238
.323
.252
.204
.288
.221
.173
.262
.195
.151
.226
.164
.121
50
50
30
10
.345
.283
.235
.309
.244
.201
.275
.215
.170
.250
.190
.148
.218
.159
.119
30
50
30
10
.331
.275
.231
.294
.239
.196
.265
.208
.168
.240
.184
.146
.209
.154
.116
10
50
30
10
.317
.266
.227
.284
.233
.193
.253
.203
.165
.231
.180
.143
.201
.150
.114
0
0
.210
.177
.149
.128
.100
% Reflectance
Eff. Ceil.
Wall
988
www.crouse-hinds.com
US: 1-866-764-5454
CAN: 1-800-265-0502
Isofootcandle Chart: Luminaire with Globe and 30°
Angle Reflector
Isofootcandle charts show illumination in footcandles on work plane
10 feet below light center. Multiply by factor shown to convert to
other mounting heights.
Height (Ft.)
Factor
Height (Ft.)
Factor
8
12
14
1.56
.694
.510
16
20
.391
.250
Copyright© 2013 Eaton’s Crouse-Hinds Business
Was this manual useful for you? yes no