MODEL UCM ... FORCED DRAFT LIGHT OIL 25,200,000 BURNERS

MODEL UCM         ... FORCED DRAFT LIGHT OIL     25,200,000 BURNERS
MODEL UC M
GAS
FORCED DRAFT
LIGHT OIL
BURNERS
®
Power Flame’s
Versatile High Capacity
Ultra Low NOx
Gas / Oil Burner
Premix Firing Head
Produces optimum fuel-air
mixture within the primary
combustion zone and
minimizes blower
horsepower
8,400,000 –
25,200,000
BTU/HR
Ma x
The Power Flame Ultra
CMAX burner offers state-ofthe- art technology for minimal
NOx emissions (under 9 PPM
on natural gas), maximum
combustion efficiency and
operating performance when firing
all types of gaseous fuels and
light oils. Designed specifically for
today’s fire tube and water tube
boilers, the Ultra CMAX burner
utilizes an advanced firing head
that combines fuel staging and
premixing to provide stable
combustion over a wide turndown
range (5:1 on gas and oil).
Moderate amounts of induced
flue gas recirculation provide
minimal emissions on gaseous
and liquid fuels. The easy access
door on the burner blast tube
allows maintenance of the firing
head components and facilitates
a quick changeover from gas to
oil firing without disturbing the fuel
piping or electrical connections.
The bottom-entry, centrally
located gas manifold connection
facilitates left or right hand
configurations.
The modular concept that is the
basis for all Power Flame burners
produces added flexibility for a
wide range of optional features.
All packaged combustion systems
are factory fire-tested to ensure
cost effective installation and
start-up.
Optional
Nema 4
control panel
and
touchscreen
display with
custom graphics
Linkageless Controls
State-of-the-art electronic
controls accurately maintain
fuel air ratios throughout
the firing range for optimum
performance
C
UCM–0111
Unique
firing head
produces
stable
combustion
and ultra low
NOx when
firing natural
gas.
S TA N D A R D EQUIPMENT
3450 RPM Motor, backward inclined blower wheel,
for reduced blower motor horsepower
Control panel with Alpha System™ LED Indicators
(Power, Demand, Main Fuel, FSG Alarm & Customer
Selectable) and control switch.
Gas electric pilot and ignition transformer
Combustion air flow safety switch
Linkageless modulating controls with integral flame
safeguard
Manual/Auto switch & manual potentiometer
IFGR for low NOx operation
GAS BURNER
Pressure regulators, pilot and main gas cocks
Adjustable gas premix firing head
UV scanner
High & low gas pressure switches
Dual gas safety shut-off valves
ADDED FEATURES
AIR ATOMIZED OIL BURNER
DirectorTM graphic annunciator
Touch screen display with custom graphics
Nozzle assembly with oil and atomizing air trains
Air compressor
Remote pump assembly
IR scanner
Dual oil safety shut-off valves
MODEL UCM
DIMENSIONS
(Forced Draft Burner)
RATINGS & SPECIFICATIONS
(Inches) Standard Models
CAPACITY *
#2
NAT.
Burner
Model
UCM200–G(O)–30
UCM250–G(O)–30
UCM300–G(O)–30
UCM350–G(O)–30
UCM400–G(O)–30
UCM500–G(O)–30
UCM600–G(O)–30
A
B
C
D
E
F
G
I
J
K
L
707/8
10 5/ 8
26 7 / 8
113/4
1 9 1/ 2
15 7 / 8
201/8
241/2
123/4
423/4
269/16
751/2
751/2
791/2
791/2
791/2
115/16
115/16
305/16
305/16
343/16
343/16
343/16
13
135/8
141/4
165/8
173/8
237/8
253/4
275/8
297/8
321/8
241/2
241/2
241/2
241/2
241/2
123/4
123/4
123/4
123/4
123/4
45
45
467/8
467/8
467/8
303/16
303/16
32
32
34
707/8
10 5/ 8
12 5/ 8
12 5/ 8
12 5 / 8
26 7 / 8
121/4
19 3/ 16
1813/16
2311/16
21 3 / 4
22 1 / 2
2511/16
16 1 / 2
17 1 / 8
17 7 / 8
185/16
19 1 / 4
19 7 / 8
215/8
241/2
123/4
® PowerFlame Incorporated
2001 South 21st Street Phone 620-421-0480
Parsons, KS 67357
Fax 620-421-0948
423/4
269/16
M
S
OIL
GPH
MAX.
221/2
119/16
119/16
13
13
151/4
151/4
151/4
60
75
90
105
120
150
180
MIN.
24
261/4
28
30
321/4
341/2
GAS
MBH
MAX.
8,400
10,500
12,600
14,700
16,800
21,000
25,200
NOMINAL
BOILER
H.P.
MAX.
BLOWER
MOTOR
H.P.
GAS **
PRESS.
REQ’D
(PSIG)
200
250
300
350
400
500
600
7.5
10.0
15.0
20.0
20.0
25.0
30.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
Note 1: Dimensions can vary with optional equipment and system arrangements.
Final piping connections should be determined after installation.
2. PFI certified capacities listed are based on +3.00” w.c. combustion
chamber pressure.
3. Gas pressures listed are at the inlet to the main shutoff cock and
required to obtain PFI certified rating with the standard UL gas train.
Optional gas trains are available for lower pressures.
Web Site: http://www.powerflame.com
E-Mail: csd@powerflame.com
Copyright © Power Flame Incorporated 2011
Printed in U.S.A.