Product Sheet for IP55 Weatherproof Digital Timer

Product Sheet for IP55 Weatherproof Digital Timer
WN/WNS Range of IP55
Weatherproof 13A wiring accessories
Products in the range
WNS - single module units
WNS50WA-C
Double pole switched socket
WNS50WN-C
Double pole switched socket with neon
WNS93WP-C
RCD fused spur unit
WNS94WA-C
Switched fuse spur unit with neon
WNS44WA-C
3 gang 10A two way switch
WNS33DT-C
24 hour digital timer
WNS34MT-C
24 hour mechanical timer
WNS35MT-C
7 day mechanical timer
WN - double module products
WN22MP-C
Twin RCD metalclad socket
WN33TS-C
24 hour timed socket
WN44WA-C
4 gang 10A two-way switch
WN55MA-C
Twin 13A socket
WN55WN-C
Twin switched socket with neon
WNGRID-C
4 way grid (for MK grid modules)
Additional information required As well as these general instructions you will need to read
the specific product/function information which has been
supplied with the following units.
WNS93WP-C
WNS33DT-C
WNS34MT-C
WNS35MT-C
Instructions for PowerBreaker H92
RCD spur unit
Instructions for T105-C timer
Instructions for T100-C timer
Instructions for T101-C timer
If this information has been mislaid see
www.greenbrook.co.uk in the ‘Products’ section.
General information
All WN/WNS products are suitable for use outdoors in
severe conditions of rain and water spray as well as dust
contamination to IP55 as defined by BS EN 60529.
All WN/WNS products are for use with a 230V 50Hz
supply.
The WNS enclosure (single module unit) has a plastic
protection piece in the cable entry port. This should be
removed in the case of sockets, but can be left in place
when there is no front cable entry. Removing this piece will
not reduce the IP rating below 55.
Installation Guide
This product should only be installed by a competent and
authorised person (e.g. a qualified electrician) in
accordance with the instructions supplied and in
accordance with the appropriate clauses of the current
edition of the IEE Wiring Regulations.
Important: Always disconnect the mains supply via the
switch in the main fuse board or consumer unit before
commencing any electrical work. Ensure that all terminal
screws are fully tightened and that earth wires are sleeved
and that no bare wires are showing.
Cable glands must be used which maintain the IP
rating. The warranty is invalid if the IP rating is not
maintained.
The mounting surface must be flat and free from grease,
dirt or loose material.
The socket, spur, switch or timer should be removed prior
to fixing the enclosure to the wall - by removing the two
front securing screws.
The enclosure can be offered up to the wall and the
fixing points marked through the mounting holes. At least
two diagonal fixing points should be used. Size 8 screws
should be used to fix the base to the wall.
Removing the lid of the WN double module
products - (The WNS single unit lids cannot be removed)
To remove the lid pull the lid to the right and lift the
left-hand side.
To replace the lid engage the righthand hinge first then the left-hand.
Opening the lid of the WN products
Squeeze the two catches
as shown and lift the lid.
Opening the lid of the WNS products
Pull the lid open at the
two catched as shown.
Cleaning
If the unit needs cleaning it should be disconnected from
the mains supply. Wipe the surface with a dry cloth. Do not
use a damp or wet cloth or a solvent based cleaning agent,
as this may damage or impair the safety of the product.