29398 Optimux

Add to my manuals
12 Pages

advertisement

29398 Optimux | Manualzz

Data Sheet

Optimux-108, Optimux-106

Four-Channel E1/T1 and Ethernet Multiplexers

Fiber Multiplexers,

Transmit Any Traffic over Fiber

Four E1 or T1 channels and Fast Ethernet link multiplexed over a fiber optic link

Various fiber interfaces: multimode, single-mode (up to 120 km), and/or single-mode over single fiber, using SFP optical modules

Automatic link backup with optional hot-swappable second main link

Card versions enable connecting up to 24 remote units to one LRS-102 rack

(12 cards)

Power redundancy with optional second wide-range power supply

Management via ASCII terminal, dedicated Ethernet port, SNMP management station, or ConfiguRAD Web-based remote access terminal

The Optimux-108 and Optimux-106 multiplexers combine four E1 or T1 channels and an optional Ethernet link over a fiber optic uplink.

A pair of Optimux units provides a simple and low-cost solution for connectivity over distances of up to 120 km (74.5 miles).

For transmission reliability, an optional modular second link provides automatic backup upon link failure. An optional second power supply provides power redundancy for failsafe operation.

Each of the four signals of the tributary interface is transmitted independently, so that each channel can be set to a different clock source.

The Access Company

Optimux-108, Optimux-106

Four-Channel E1/T1 and Ethernet Multiplexers

STANDALONE UNITS

Uplink Interfaces

Optimux-108 and Optimux-106 support a variety of built-in optical uplink interfaces including:

• 850 nm VCSEL (Vertical Cavity Surface

Emitting Laser) for multimode fiber

• 1310 nm LED for multimode fiber

• 1310/1550 nm laser diode or long haul laser diode for extended range over single-mode fiber

• Single fiber (SF1, SF2 options) using a

1310 nm and 1550 nm laser diode transmitter with WDM technology, which enables the laser to transmit the signal at a different wavelength than the receive signal

• Single fiber (SF3 option) using SC/APC

(Angle-Polished Connector) technology, with a 1310 nm laser diode for single wavelength operation.

The basic models include a fiber optic uplink and four tributary E1/T1 links. The standalone units are supplied with balanced E1 and T1 interfaces.

Optimux-108 can be ordered with unbalanced E1 interfaces.

Optimux-108/106 can be ordered with an additional Ethernet user port, and with redundant uplink. Optimux-108 can also be ordered with a V.35 interface in place of the Ethernet user port.

Diagnostics

Optimux features comprehensive test and diagnostics capabilities that include local and remote loopbacks on the uplink interface and on each E1/T1 tributary link.

A local loopback is also supported on the optional V.35 user port.

To facilitate system diagnostics,

Optimux-108 and Optimux-106 feature

LED status indicators, AIS alarm generation and recognition, and dry contact closure upon link failure.

Management

Optimux-108 and Optimux-106 can be configured and monitored locally using an

ASCII terminal connected to the control port or remotely via the Ethernet management port using:

• RADview-EMS running in a

Windows or Unix environment

• ConfiguRAD Web-based remote access terminal

• Telnet.

Power

The power supply is a wide-range AC/DC power supply that can be connected to either an AC power source (100 to

240 VAC), or a DC power source

(–40 to -72 VDC). An optional second power supply provides redundancy. As an option, the devices can also be ordered with a non-redundant 24 VDC power supply (20 to 36 VDC).

Physical

Optimux-108 and Optimux-106 are compact standalone units, available in plastic or metal enclosures. Both enclosures are available in extended temperature versions. The optional rack mount adapter kits enable installation of one or two (side-by-side) units in a

19-inch rack.

Figure 1. Ethernet, Voice, Data and Video Services Over Fiber

Data Sheet

CARD MODULES

The OP-108C and OP-106C multiplexers are cards designed for operation in the

LRS-102 chassis. They combine up to eight E1 or T1 channels and two optional

Ethernet links over two fiber optic links from two remote units (up to four E1/T1 and 100 Mbps Ethernet traffic from each remote unit).

The LRS-102 chassis can contain up to

12 cards (24 links). An Optimux link provides a simple and low-cost solution for connectivity over distances of up to

120 km (74.5 miles).

Uplink Interfaces

Pluggable SFP units provide the uplink interfaces. A wide variety of optical interfaces are available for ordering as single, dual, or quad modules (see

Table 2

and

Ordering Options

).

It is strongly recommended to order this device with original RAD SFPs installed.

This will ensure that prior to shipping,

RAD has performed comprehensive functional quality tests on the entire assembled unit, including the SFP devices. RAD cannot guarantee full compliance to product specifications for units using non-RAD SFPs.

Redundancy

For transmission reliability, an optional modular second link provides automatic backup upon link failure. LRS-102 provides power redundancy for nonstop operation.

Diagnostics

OP-106C and OP-108C feature comprehensive test and diagnostics capabilities that include local and remote loopbacks on the uplink interface and on each E1/T1 tributary link.

To facilitate system diagnostics, the card versions feature LED status indicators and

AIS alarm generation and recognition.

Management

Setup, control, and diagnostics are performed by the LRS-102 management rack. The same management options are available as for the standalone versions.

Physical

Each card fits in a single slot of the

LRS-102 chassis.

Note:

For OP-106C/OP-108C cards operating in the Megaplex-4100 enclosure, refer to a separate OP-106C/OP-108C data sheet included into the Megaplex-4100 folder.

Power

The power for cards is provided by the

LRS-102 power supply.

Optimux-108, Optimux-106

Four-Channel E1/T1 and Ethernet Multiplexers

Specifications

TRIBUTARY INTERFACES

Number of E1/T1 Channels

Standalone: 4

Card: 2 x 4 E1/T1 channels

Data Rate

E1: 2048 kbps

T1: 1544 kbps

Line Code

E1: HDB3

T1: B8ZS

Impedance

120Ω, E1 balanced

100Ω, T1 balanced

75Ω, E1 unbalanced

Connectors

Optimux-108

E1 balanced: RJ-45

E1 unbalanced: two BNC

Optimux-106

T1: RJ-45

OP-108C

E1 balanced: DB-44 connector on the front module panel convertible to

80 balanced interfaces via adaptor cables

(see

Ordering Options

)

E1 unbalanced:

• DB-44 connector on the front module panel convertible to 80 unbalanced interfaces via adaptor cables (see

Ordering Options

)

• two BNC connectors for each E1 port on a special LRS-102 rack

OP-106C

DB-44 connector on the front module panel convertible to 80 balanced T1 interfaces via adaptor cables

(see

Ordering Options

)

Figure 2. Corporate Service Sharing

Data Sheet

Table 1. Standalone Fiber Optic Interface Characteristics (Optimux-108, Optimux-106 without the Ethernet port)

Wavelength

[nm]

850

1310

1310

1550

1310

1550

Fiber Type

[μm]

9/125 single mode

9/125 single mode

Tx: 1310 Rx 1550 9/125 single mode

Tx: 1550 Rx 1310 9/125 single mode

Tx/Rx: 1310 9/125 single mode

Transmitter Type

62.5/125 multimode Laser (VCSEL)

9/125 single mode Laser

62.5/125 multimode LED

9/125 single mode Laser

Laser (long haul)

Laser (long haul)

Laser WDM (SF1)

Laser WDM (SF2)

Laser (SF3)

Typical Power

Output

[dBm]

-7

-12

-18

-12

-2

-2

-12

-12

-12

Receiver

Sensitivity

[dBm]

-34 (see Note 2) 6

-34 47

-32

-34

7

47

-34

-34

72

120

-34

-34

-27

Typical Max. Range Connector Type

[km]

47

47

20

[miles]

3.7

29.2

4.3

29.2

44.7

74.5

29.2

29.2

12.4

ST, SC, FC/PC

ST, SC, FC/PC

ST, SC

ST, SC, FC/PC

ST, SC, FC/PC

ST, SC, FC/PC

SC

SC

SC/APC only

Note 1. Typical ranges are calculated according to attenuation of 3.5 dB/km for 850 nm multimode fiber, 0.4 dB/km for 1310 nm single mode fiber, and 0.25 dB/km for

1550 nm single mode fiber.

Note 2. The Receiver Sensitivity for units with the Ethernet port is 32 dBm.

Note 3

.

For information on Optimux-108, Optimux-106 with the Ethernet port, refer to the Optimux-106 Installation and Operation Manual and Optimux-108 Installation and Operation manual, respectively.

Optimux-108, Optimux-106

Four-Channel E1/T1 and Ethernet Multiplexers

Table 3. SFP Fiber Optic Interface Characteristics

Module Name

(Ordering

Option)

Wavelength Fiber Type

[nm]

Transmitter

Type

Typical Output

Power

[dBm]

Receiver

Sensitivity

[dBm]

Typical Max Range Connector

Type

[km] [miles]

SFP-1

SFP-2

SFP-3

SFP-4

SFP-10a

SFP-10b

SFP-18A

SFP-18B

1310

1310

1550

Tx –1310,

Rx –1550

Tx –1550,

Rx –1310

Tx – 1310,

Rx – 1550

Tx – 1550,

Rx – 1310 multimode

9/125 single mode

9/125 single mode

9/125 single mode

9/125 single mode

(single fiber)

9/125 single mode

(single fiber)

9/125 single mode

(single fiber)

9/125 single mode

(single fiber)

LED

Laser

Long haul laser

Long haul laser

Laser WDM

Laser WDM

Laser WDM

Laser WDM

-18

-12

-2

-2

-12

-12

-31

-31

-34

-34

-30

-30

6.5

38

70

120

40

40

4.0

23.6

43.4

74.5

24.8

24.8

LC

SFP-19A

SFP-19B

SFP-24

Tx – 1490,

Rx – 1550

Tx – 1550,

Rx – 1490

9/125 single mode

(single fiber)

9/125 single mode

(single fiber) multimode

Laser WDM

Laser WDM

VCSEL -7 -31 6.5

4.0

Note: Typical ranges are calculated according to attenuation of 0.4 dB/km for 1310 nm single mode fiber and 0.25 dB/km for 1550 nm single mode fiber.

LC

LC

LC

LC

LC

LC

FIBER OPTIC INTERFACES

Optimux-108/Optimux-106: See

Table 1

OP-108C/OP-106C: See

Table 2

MNG–ETH INTERFACE

(STANDALONE ONLY)

Type

10/100BaseT

Connector

Shielded RJ-45

USER-ETH INTERFACE

Type

10/100BaseT

Connector

Shielded RJ-45

Throughput

100 Mbps (Optimux-108, OP-108C)

75 Mbps (Optimux-106, OP-106C)

V.35 USER INTERFACE

(E1 STANDALONE ONLY)

Type

DCE

Connector

Smart Serial

Throughput

2 Mbps

CONTROL PORT (STANDALONE ONLY)

Type

RS–232 DCE asynchronous

Data Rate

9.6, 19.2, 38.4, 57.6, 115.2 kbps

Connector

Mini-USB 5

ALARM PORT (STANDALONE ONLY)

Type

Dry relay contacts for major and minor alarms

Connector

RJ-45

Data Sheet

Figure 3. Cellular Range Extension over Fiber

Optimux-108, Optimux-106

Four-Channel E1/T1 and Ethernet Multiplexers

STANDALONE INDICATORS

Front Panel

PWR

On (green): both power supplies OK

On (red): power supply A fault

On (yellow): power supply B fault

Off: power supply fault

LINK A/B

On (red): Sync/Signal Loss on Link A/B

On (yellow): AIS detected (products without Ethernet port only)

Off: normal operation

CH1 to CH4

On (red): Signal Loss on channel

On (yellow): AIS received on channel

Off: normal operation

Rear Panel

Sig Link A/B (on the fiber optic module)

On (green): signal exists on Link A/B

Off: no signal on Link A/B

LINK/ACT

On (yellow): link is up

Off: link is down

Flashes: frames are transmitted

100

On (green): 100 Mbps mode

Off: 10 Mbps mode

CARD INDICATORS

Link

OP A/B LOSS

On (red): Sync/Signal Loss on OP A/B

Off: Normal operation

OP A/B AIS

On (yellow): AIS detected

(only for operating opposite port)

Off: Normal operation

(OP A/B LOSS and AIS are on if the SFP is not inserted.)

Ethernet

OP A/B LINK/ACT

On (yellow): link is up

Off: link is down

Flashes: frames are transmitted

OP A/B 100

On (green): 100 Mbps mode

Off: 10 Mbps mode

Data Sheet

GENERAL

Standards

G.703, G.823 (E1), G.824 (T1), G.955,

IEEE 802.3, G.742 (Optimux-108 without

Ethernet ports)

Diagnostics

Local and remote loopbacks on uplink and on each E1/T1 tributary link

Local loopback on optional V.35 user port

(Optimux-108 only)

Timing

Uplink: internal

E1/T1 tributary: transferred transparently, independent for each channel

V.35: internal, external, loopback

(Optimux-108 only)

Power

Standalone:

Wide range power supply

• AC: 100 to 240 VAC

• DC: –48 VDC (–40 to –72 VDC)

24 VDC power supply

• 24 VDC (20 to 36 VDC)

Card: supplied by LRS-102

Power Consumption

Standalone:

• Wide range AC: 25 VA max

• Wide range DC (-48VDC): 9W max

• 24 VDC: 9W max

Card: 9W max

Physical

Standalone plastic enclosure:

Height: 4.37 cm (1.7 in)

Width: 21.7 cm (8.5 in)

Depth: 17.0 cm (6.7 in)

Weight: 0.5 kg (1.1 lb)

Standalone metal enclosure:

Height: 4.37 cm (1.7 in)

Width: 21.5 cm (8.4 in)

Depth: 15.3 cm (6.0 in)

Weight: 0.7 kg (1.5 lb)

Card: fits into the LRS-102 rack

Environment

Temperature: 0° to 50°C (32° to 122°F)

Extended temperature range

(standalone units, hardened version only):

-20° to 60°C (-4° to 140°F)

Note: The extended temperature range for

Optimux-108, Optimux-106 with V35 interface is

-10° to 60°C (14° to 140°F.)

Humidity: Up to 90%, non-condensing

Figure 4. Range Extension of 4xE1 over Fiber

Optimux-108, Optimux-106

Four-Channel E1/T1 and Ethernet Multiplexers

Ordering

STANDALONE UNITS

OP-108/~/

^

/%/!/#/+/$/*/?

Four-Channel E1 and Ethernet Multiplexer

OP-106/~/%/!/#/+/$/*/?

Four-Channel T1 and Ethernet Multiplexer

Uplink modules

OP-108-M/#/+/$/?

OP-106-M/#/+/$/?

Legend

~

Power supply (Default=AC/DC widerange power supply):

24 24 VDC

^

E1 connector:

B Balanced (RJ-45)

U Unbalanced (BNC)

% Redundant power supply:

(Default=one power supply)

R Redundant power supply of the same type

(not for 24 VDC)

! Optional user port:

ETH 10/100BaseT Ethernet

V35 V.35 (Optimux-108 only)

# Uplink interface connector

ST ST type connector

FC

SC

FC/PC type connector

SC type connector

Note: ST and FC connectors are not available for the single fiber options.

+ Fiber optic link interface:

85L 850 nm, multimode, VCSEL

13 1310 nm, multimode, LED

Note: Available with ST and SC connectors only.

13L 1310 nm, single mode, laser diode

15L 1550 nm, single mode, laser diode

SUPPLIED STANDALONE ACCESSORIES

AC power cord

DC adapter plug

CBL-MUSB-DB9F

Control port cable

CBL-RJ45-DB9/F

Alarm port cable long-haul laser diode long-haul laser diode

SF1 Transmit 1310 nm laser

(WDM), receive 1550 nm

SF2 Transmit 1550 nm laser

(WDM), receive 1310 nm

SF3 Transmit and receive at 1310 m laser diode

$ Extended temperature version

(Default=no extended temperature support):

H Extended temperature support

(13L, 15L, 13LH, 15LH fiber link versions only)

* Redundant uplink module

(Default=single uplink)

D Second uplink module (of same type as first uplink module)

Note: For single fiber applications, a device with SF1 interface is always used opposite a device with SF2 interface, and vice versa. An SF3 interface works only opposite another

SF3 interface.

? Enclosure (Default=plastic enclosure)

ME Metal enclosure

OPTIONAL STANDALONE ACCESSORIES

RM-33-2

Hardware kit for mounting one or two plastic units in a 19-inch rack

RM-35/@

Hardware kit for mounting one or two metal units in a 19-inch rack

Legend

@ Rack mount kit (Default=both kits):

P1 Mounting one unit

P2 Mounting two units

CBL-AMP-M34

Smart Serial (V.35) to M34 interface

CBL-AMP-DB25-ISO2110

Smart Serial (V.35) to ISO 2110 interface

CBL-AMP-DB25-TLBS

Smart Serial (V.35) to Telebras interface

CARD MODULES FOR LRS-102

Note: For OP-106C/OP-108C cards operating in the

Megaplex-4100 enclosure, refer to a separate

OP-106C/OP-108C data sheet included into the

Megaplex-4100 folder.

OP-108C/^/!/+

OP-106C/!/+

Legend

 

^ E1 connector:

B Balanced (RJ-45)

U Unbalanced (BNC connectors on a special LRS-102 rack, E1 only)

! Optional Ethernet user port:

(Default=no port)

ETH 10/100BaseT Ethernet port

+ SFP fiber optic link interface:

Note: It is strongly recommended to order this device with original RAD SFPs installed. This will ensure that prior to shipping, RAD has performed comprehensive functional quality tests on the entire assembled unit, including the SFP devices. RAD cannot guarantee full compliance to product specifications for units using non-RAD SFPs.

SFP1

SFP2

SFP3

SFP4

SFP10A

SFP10B

SFP24

SFP18A

SFP18B

LED, 1310 nm, multimode,

LC only

Laser, 1310 nm, single mode, LC only

Long-haul laser, 1310 nm, single mode, LC only

Long-haul laser, 1550 nm, single mode, LC only

Laser WDM, Tx –1310 nm,

Rx –1550 nm, single mode, single fiber, LC only

(SF1)

Laser WDM, Tx –1550 nm,

Rx –1310 nm, single mode, single fiber, LC only

(SF2)

VSCEL, 850 nm, multimode, LC only

Laser WDM, Tx –1310 nm,

Rx –1550 nm, single mode, single fiber, LC only

Laser WDM, Tx –1550 nm,

Rx –1310 nm, single mode, single fiber, LC only

SFP19A

SFP19B

2XSFP1

2XSFP2

2XSFP3

2XSFP4

Laser WDM, Tx –1310 nm,

Rx –1550 nm, single mode, single fiber, LC only

Laser WDM, Tx –1550 nm,

Rx –1310 nm, single mode, single fiber, LC only

Dual SFP1 modules

Dual SFP2 modules

Dual SFP3 modules

Dual SFP4 modules

2XSFP10A Dual SFP10A modules

2XSFP10B Dual SFP10B modules

2XSFP18A Dual SFP18A modules

2XSFP18B Dual SFP18B modules

2XSFP19A Dual SFP19A modules

2XSFP19B Dual SFP19B modules

2XSFP24 Dual SFP24 modules

4XSFP1 Quad SFP1 modules

4XSFP2 Quad SFP2 modules

4XSFP3 Quad SFP3 modules

4XSFP4 Quad SFP4 modules

4XSFP10A Quad SFP10A modules

4XSFP10B Quad SFP10B modules

4XSFP18A Quad SFP18A modules

4XSFP18B Quad SFP18B modules

4XSFP19A Quad SFP19A modules

4XSFP19B Quad SFP19B modules

4XSFP24 Quad SFP24 modules

Note: For single fiber applications, a device with

SFP-10A interface is always used opposite a device with SFP-10B interface, and vice versa.

Data Sheet

Data Sheet

Optimux-108, Optimux-106

Four-Channel E1/T1 and Ethernet Multiplexers

OPTIONAL CARD ACCESSORIES

CBL-G703-8/RJ45

Splitter cable for splitting the

44-pin card connector to 8 E1 or 8 T1 balanced RJ-45 connectors

CBL-G703-8/RJ45/X

Splitter cross-cable for splitting the

44-pin card connector to 8 E1 or 8 T1 balanced RJ-45 connectors

CBL-G703-8/COAX

Splitter cable for splitting the

44-pin OP-108C card connector to 8 pairs of unbalanced BNC connectors

CBL-G703-8/OPEN/2M

Open-ended cable with DB-44 connector on the LRS-102 side for balanced E1 or T1 applications

All cables are 2m (6.6 ft) long.

Table 3. Optimux Comparison Chart

Feature

Uplink

Optimux-108 Optimux-106 Optimux-34 Optimux-25 Optimux-45/45L Optimux-1551 Optimux-1553

Fiber Optic Fiber Optic E3, Fiber Optic Fiber Optic T3, Fiber Optic Copper,

STM-1/OC-3

Copper,

STM-1/OC-3

108 81 34 25 45 155 155 Bandwidth

(Mbps) trunks

Ethernet

4 E1

9

4 T1

9

Special Redundant, hot-swappable uplinks

Card version for

LRS-102

Redundant, hot-swappable uplinks

Card version for

LRS-102

16 E1

9

SFP-based uplinks

16 T1

9

SFP-based uplinks

21 E1

28 T1

21/42/63 E1

28/56/84 T1

3 E3

3 T3

– – –

Ring support

(Optimux-45)

Full redundancy Full redundancy

International Headquarters

24 Raoul Wallenberg Street

Tel Aviv 69719, Israel

Tel. 972-3-6458181

Fax 972-3-6498250, 6474436

E-mail [email protected]

North America Headquarters

900 Corporate Drive

Mahwah, NJ 07430, USA

Tel. 201-5291100

Toll free 1-800-4447234

Fax 201-5295777

E-mail [email protected]

www.rad.com

Order this publication by Catalog No. 803830

The Access Company

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Download PDF

advertisement