S16000-0001-4 6/00 16000 Series Annunciators

S16000-0001-4 6/00 16000 Series Annunciators
®
Multi-Application Peripherals
and Accessories
Annunciator
16000 Series
ULC Listed
FEATURES:
•
•
•
•
•
•
Surface or Semi-Flush Mount
Shallow Wall Mounting
Long Life LEDs
Lamp Test
Power On LEDs
Audible and Visual Common Trouble
FIRE ALARM
ANNUNCIATOR
DESCRIPTION:
The 16000 series annunciator is a companion
to the 4002 series of fire alarm controls. It may also be
used in other applications where an LED type of annunciator is desired. The 16000 series
annunciator has a tamper proof face with no
exposed screws or fasteners.
®
Simplex
The zone LEDs are for use with 24VDC power
supplies. Power for their operation may be obtained from a
4002 control panel or from some other
compatible source.
Zone designations can be either numeric (‘Zone 1’, ‘Zone
2’, etc.) or custom descriptions (‘Main Lobby’, etc.).
© Simplex International Time Equipment Co. Ltd.
16000-9012 Annunciator
S16000-0001-4 6/00
W
D
H
Semi-Flush Backbox
D
W
H
Surface Backbox
S16000-0001-4 6/00 Page 2
D
W
FIRE ALARM
ANNUNCIATOR
H
®
Simplex
Surface/Semi-flush Annunciator
DIMENSIONS
IN INCHES
TYPE
MODEL NUMBER
ZONES
HEIGHT
WIDTH
DEPTH
16000-9011
16000-9012
16000-9013
16000-9014
16000-9015
8
16
34
52
70
13
13
13
20
20
9 5 16
9 5 16
14 12
14 3 4
14 3 4
1
SURFACE
MOUNT
BACKBOX
2975-9319C
2975-9320C
2975-9321C
8/16
34
52/70
13 3 16
13 3 16
20 3 16
9 12
14 1116
14 15 16
4
4
4
SEMI-FLUSH
MOUNT
BACKBOX
2975-9322C
2975-9317C
2975-9318C
8/16
34
52/70
11 3 4
11 3 4
18 3 4
8 116
13 14
13 12
4
4
4
SURFACE/
SEMI-FLUSH MOUNT
ANNUNCIATOR
1
1
1
1
2
2
2
2
2
S16000-0001-4 6/00 Page 3
Terminal Designation
Primary Block
G
POWER ON
R
TROUBLE
A
ZONE 1
ZONE 2
R
R
ZONE 3
ZONE 4
R
R
ZONE 5
ZONE 6
R
R
ZONE 7
ZONE 8
R
R
ZONE 9
ZONE 10
R
R
ZONE 11
ZONE 12
R
R
ZONE 13
ZONE 14
R
R
ZONE 15
ZONE 16
R
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
+24VDC COMMON POSITIVE
TROUBLE BUZZER POSITIVE
TROUBLE BUZZER NEGATIVE
0VDC FOR LAMP TEST
TROUBLE LIGHT POSITIVE
TROUBLE LIGHT NEGATIVE
0VDC FOR POWER ON LED
ZONE 1
ZONE 2
ZONE 3
ZONE 4
ZONE 5
ZONE 6
ZONE 7
NOTE: POSITIVE COMMON
ZONE 8
LED ANNUNCIATOR
ZONE 9
ZONE 10
ZONE 11
ZONE 12
ZONE 13
ZONE 14
ZONE 15
ZONE 16
*LAMP TEST OPTIONAL LOOP
Terminal Designation
Secondary Block
®
R
ZONE 1
ZONE 2
R
R
ZONE 3
ZONE 4
R
R
ZONE 5
ZONE 6
R
R
ZONE 7
ZONE 8
R
R
ZONE 9
ZONE 10
R
R
ZONE 11
ZONE 12
R
R
ZONE 13
ZONE 14
R
R
ZONE 15
ZONE 16
R
R
ZONE 17
ZONE 18
R
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
+24VDC COMMON POSITIVE
NOT USED
NOT USED
0VDC FOR LAMP TEST
CONNECTED INTERNALLY TO 1
ZONE 2
ZONE 1
ZONE 3
ZONE 4
ZONE 5
ZONE 6
ZONE 7
ZONE 8
ZONE 9
ZONE 10 NOTE: POSITIVE COMMON
LED ANNUNCIATOR
ZONE 11
ZONE 12
ZONE 13
ZONE 14
ZONE 15
ZONE 16
ZONE 17
ZONE 18
*LAMP TEST OPTIONAL LOOP
S16000-0001-4 6/00
2400 Skymark Avenue, Mississauga, Ontario L4W 5K5
Offices and Representatives Throughout the World
Visit us on the World Wide Web @www.simplexnet.com
All specifications and other information shown were current as of printing and are subject to change without notice.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising