MDM-2156_5hp_Specs

MDM-2156_5hp_Specs
MDM-2156 5HP
1
4
11
2
3
5
6
8
Non-contact Bearing System allows dry
run operation (CF models only)
Y
Simple, rugged design
Y
Corrosion resistant ETFE & PFA internals
Y
Spline/pinned impeller design (pat.
pending) provides positive locking of
impeller/inner magnet while still allowing
for individual replacement of each part
Y
PFA version temperatures to 302°F
(m) FT
10
7
Y
140
20% 30%
5.71"
9
40%
45%
50%
55%
40
60%
5.50"
Part
1
2
3
4
Material
EKK
ECF
Front casing
Containment shell
Impeller
Inner magnet assy
120
PKK
35
5.125"
CFRETFE
(carbon fiber reinforced
ETFE)
PFA
100
30
4.75"
High
density
carbon
High purity
alumina
ceramic
5 Bearing
6 Shaft
7 Front outboard thrust
collar
8 Front inboard thrust
collar
80
25
5 HP
4.375"
SiC
20
60
3 HP
PTFE
High purity
alumina
ceramic
9 Rear inboard thrust
collar
10 Rear outboard thrust
collar
11 Gasket
NPSHR
FT (m)
15
25 7
20 6
5
15
4
10 3
5 2
40
PTFE (filler charged)
PTFE
10
PTFE
TDH
20
Dimensions (inches) and Specifications
0
Note: Will vary by motor manufacturer
25
100
OUT
HC (3)
50
75
100
125
150
FLOW
C
M
200
300
400
500
600
AC (3)
X
O
L
K
IN
D
G2
H2 (5)
H3 (7)
A
11.0
2
AC(3)
B(3)
5.76
17.41
G1
F1
F2
D
B (3)
2E1
2E2
F1
7.09
8.66
9.45
6.89
H1 (6)
0.39"
F2
G1
13.68
0.60
G2
2.62
H1 (6)
0.55
2E1
2E2
A
H2 (5)
H3
0.63
0.63
HC (3)
O
X
Y
25.13
13.39
6.50
4.00
HP/Frame
Connection
Sizes
Min Flow/Max
Head
Standard
Capacity
Max
Capacity
Pump
Weight*
K
L
C
M
5/184TC
2 x 1.5
13/131
115
150
132
6.50
3.78
5.51
3.07
*Pump end only. Does not include motor.
IF20428.D 8/04
5 BOYNTON ROAD HOPPING BROOK PARK
HOLLISTON, MA 01746-1446 USA
TEL: 508-429-1440
FAX: 508-429-1386 WEBSITE: WWW.IWAKIAMERICA.COM
GPM
LPM
Was this manual useful for you? yes no