MEAN WELL - Catalogo Alimentatori

MEAN WELL - Catalogo Alimentatori
DIN Series
10~96W Miniature Single Output
MDR-20
M D R - 10
M D R -4 0
MDR-60
M D R -1 00
Features
•
•
•
•
•
•
Uni v ers al AC i nput / F ul l range
Ins tal l ed on DIN rai l T S 35 / 7.5 or 15
Protec ti ons : Short c i rc ui t / O v erl oad / O v er v ol tag e
No l oad power c ons um pti on < 0.75W (< 1W for MDR-100)
LED i ndi c ator for power on
NEC c l as s 2 / LPS c om pl i ant (s el ec ted model s )
•
•
•
•
•
•
Bui l t-i n ac ti v e PF C and ov er tem p. prot ec t i on (M DR-100)
DC OK s i gnal output (M DR-10/20)
DC OK r el ay c ontac t (MDR-40/ 60/100)
Cool i ng by free ai r c onv ec ti on
100% ful l l oad burn- i n tes t
3 y ears warranty
General Specification (Please refer to www.meanwell.com for detail spec.)
MDR-10
Mo d el No .
AC in p u t vo ltag e r an g e
MDR-20
M DR-40
85~ 264VAC, 120~ 370VDC
Col d s tart, 35A at 115VAC, Col d s ta rt, 2 0A at 115VAC,
AC in r u sh cu rr en t
DC ad ju stm en t r an g e
O ver lo ad p ro tectio n
M DR -100
M DR-60
70A at 230VAC
40A at 23 0VA C
Co l d s ta rt, 3 0A at 115VA C, 60 A at 2 30VAC
F i x ed
±10% rate d ou tput v ol tage
> 105% hi c c up mode,
105% ~ 16 0% c o ns ta nt c urre nt
auto-rec ov ery
l i mi ti ng, au to-rec ov e ry
O ver vo ltag e p ro tectio n
115% ~ 135% rated output v ol tage
Setu p , r ise, h o ld u p tim e
500ms , 30ms , 50ms at ful l l oad a nd 230VAC
With stan d vo ltag e
Wo r kin g tem p er atu re
I/P-O/P:3k VAC, I/P-F G:1.5k VAC, 1m i nu te
DC O K sig n al
Open c ol l ec tor
0 ~ + 2 0 % rated output v ol tage
10 5% ~ 150 % c o ns tan t c urrent l i m i ti n g, aut o-rec ov ery
125 % ~ 150 % rated output v ol tage
3000ms , 50m s, 50ms
-20~ + 70 O C (refer to output derati ng c urv e)
O pen c o l l ec tor
-10~+ 60 O C
Rel ay c on t act
UL508, T UV EN60950-1, UL60950-1(M DR-4 0/6 0) ap pro v e d , NEC c l a s s 2 com pl i ant (MD R-10/20, MD R-40-12/24/48,
Safety stan d ar d s
MDR-60-12/24/48, MDR-100-24/48)
EMC stan d ard s
EN55022 class B, EN61000-3-2,-3, ENV50204, EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN61000-6-2 heavy industry level (MDR-40/60/100)
Co n n ectio n
Dim en sio n (W xHxD)(m m )
I/P: 3 pol es , O/P: 3 pol es s c rew DIN term i nal
IP: 3 pol es, O /P: 6 pol es s c rew DIN term inal
22.5x 90x 100
40 x 9 0x 100
Packin g
72pc s / 13.2k g
72pc s / 1 4.7k g
MDR-10 Series
Model No.
MDR-10-5
MDR-10-12
MDR-10-15
MDR-10-24
4 2pc s / 13 .6k g
42pc s / 14.8k g
30pcs / 13. 6k g
MDR-60 Series
Output
5V, 0~2.0A
12V, 0~0.84A
15V, 0~0.67A
24V, 0~0.42A
Tol.
±5%
±3%
±3%
±2%
R&N
80mV
120mV
120mV
150mV
Effi.
77%
81%
81%
84%
Output
5V, 0~3.0A
12V, 0~1.67A
15V, 0~1.34A
24V, 0~1.00A
Tol.
±2%
±1%
±1%
±1%
R&N
80mV
120mV
120mV
150mV
Effi.
76%
80%
81%
84%
Output
5V, 0~6.00A
12V, 0~3.33A
24V, 0~1.70A
48V, 0~0.83A
Tol.
±2%
±1%
±1%
±1%
R&N
80mV
120mV
150mV
200mV
Effi.
78%
86%
88%
88%
Model No.
M DR-60-5
M DR-60-12
M DR-60-24
M DR-60-48
MDR-20 Series
Model No.
MDR-20-5
MDR-20-12
MDR-20-15
MDR-20-24
55x 90x 100
Output
5V, 0~10.0A
12V, 0~5.00A
24V, 0~2.50A
48V, 0~1.25A
Tol.
±2%
±1%
±1%
±1%
R&N
80mV
120mV
150mV
200mV
Effi.
78%
86%
88%
87%
MDR-100 Series
Output
Tol.
R&N
Effi.
M DR-100 -12
Model No.
12V, 0~7.5A
±1%
120mV
85%
M DR-100 -24
24V, 0~4.0A
±1%
150mV
86%
M DR-100 -48
48V, 0~2.0A
±1%
200mV
88%
MDR-40 Series
Model No.
MDR-40-5
MDR-40-12
MDR-40-24
MDR-40-48
Energy Saving —
We care about energy saving. This logo represents
that this model has "low no load power consumption"!
To satisfy our customers is our goal —
• High Quality
• Low Cost
• Prompt Delivery
• Best Service
22
DIN Series
1 5 ~ 1 0 0 W C l a s s II S i n g l e O u t p u t
Features
• Is ol ati on Cl as s II
• Uni v ers al AC i nput / F ul l range
• Protec ti ons : Short c i rc ui t / O v erl oad /
O v er v ol tage
• O v er temperature protec t i on (DR-100)
• No l oad power c ons umpti on< 1W (DR-100)
• No l oad power c ons umpti on< 0.5W (DR-15 )
• Ins tal l ed on DIN rai l T S35 / 7.5 or 15
• Cool i ng by free ai r c onv ec ti on
• LED i ndi c ator for power on
• 100% ful l l oad burn-i n t es t
• 3 y ears warranty
• Sui tabl e for bui l di ng automati on and control of
hous ehol d appl i anc e
NEW
D R -1 0 0
DR-60
DR-30
D R - 15
General Specification (Please refer to www.meanwell.com for detail spec.)
Mo d el No .
DR-15
AC in p u t vo ltag e r an g e
AC in r u sh cu rr en t (m ax.)
DC ad ju stm en t r an g e
DR-30
DR-60
Col d s tart,
Col d s ta rt,
Co l d s ta rt,
Co l d s ta rt,
65A at 230VAC
30A at 23 0VAC
36 A at 23 0VA C
45 A at 23 0VA C
NEW
85~ 264VAC, 120~ 370VDC
DR-100
8 8~ 26 4VAC, 124 ~370VDC
12 V: 1 2~ 15V, 15V: 15~ 18V, 24V:
±10% rated output v ol tage
24 ~ 29V
O ver lo ad
Ran g e
105% ~ 160%
10 5% ~ 135 %
Pr o tectio n
Typ e
c ons tant c urrent l i mi ti ng, auto-rec ov ery
O ver Vo ltag e
Ran g e
115% ~ 135% rated output v ol tage
Pr o tectio n
Typ e
Shut off, clamp by zener diode
125% ~ 155% rated out put vol tage
Shut down, re -power o n to rec ov e r
With stan d vo ltag e
I/P-O/P: 3k VAC
Wo r kin g tem p er atu r e
-20°C~ + 60°C (refer to output l oad derati ng c urv e)
Vib r atio n
10~ 500Hz , 2G 10 mi n./1 c y c l e, peri od for 60 mi n . eac h a l on g X, Y, Z ax es
Safety stan d ard s
UL60950-1, T UV60950-1 approv e d
EMC stan d ard s
EN55022 class B, EN61000-3-2,3, EN61000-6-2, EN61000-4-2,3,4,5,6,8,11, ENV50204, EN61204-3
I/P and O/P:
Co n n ectio n
I/P: 2 pol es ,
2 pol es s c rew DIN termi nal
O /P: 4 p ol e s s c rew DIN termi na l
Dim en sio n (W xHxD)(m m )
25x 93x 56
78x 9 3x 56
78 x 93 x 5 6
100x 93x 56
Case No .
985A
918B
9 18B
970A
Packin g
140pc s / 15.0k g
48pc s / 14.0 k g
48p c s / 1 5.4kg
36pc s / 13.6k g
15W
NEW
Model No.
DR-15-5
DR-15-12
Output
Tol.
R&N
60W
DR-15
DR-60
Effi.
Model No.
DR-60-5
R&N
Effi.
80mV
76%
±2%
80mV
77.0%
12V, 0~1.25A
±1%
120mV
84.0%
DR-60-12
12V, 0~4.5A
±1%
120mV
82%
15V, 0~4.0A
±1%
120mV
83%
24V, 0~2.5A
±1%
150mV
84%
DR-15-15
15V, 0~1.00A
±1%
120mV
83.5%
DR-15-24
24V, 0~0.63A
±1%
150mV
85.0%
DR-60-24
30W
DR-30
Model No.
Tol.
±2%
5V, 0~2.40A
DR-60-15
Tol.
R&N
Effi.
5V, 0~3.0A
±2%
80mV
74%
DR-30-12
12V, 0~2.0A
±1%
120mV
81%
DR-30-15
15V, 0~2.0A
±1%
120mV
82%
DR-30-24
24V, 0~1.5A
±1%
150mV
83%
DR-30-5
Output
5V, 0~6.5A
Output
100W
We provide specification, drawing, test report and more
information, please visit our website —
http://www.meanwell.com
DR-100
Model No.
Output
Tol.
R&N
Effi.
DR-100-12
12V, 0~7.5A
±2%
120mV
87%
DR-100-15
15V, 0~6.5A
±1%
120mV
87%
DR-100-24
24V, 0~4.2A
±1%
150mV
89%
Energy Saving —
We care about energy saving. This logo represents
that this model has "low no load power consumption"!
23
DIN Series
45~480W Single Output
Features
• Universal AC input / Full range (DR-45/75, DRP-240)
AC input selectable by switch (DR-120, DRP-480S)
AC input 180~264VAC only (DRP-480)
• Built-in active PFC function, PF>0.95(DRP-240)
• Built-in passive PFC function compliance to
EN61000-3-2 (480W models)
• Protections: Short circuit / Overload /
Over voltage / Over temperature
DR-45
DR-75
DR-120
• Cooling by free air convection
DRP-480
DRP-480S
DRP-240
• Can be installed on DIN rail TS35 / 7.5 or 15
• UL508 (industrial control equipment) listed
• 100% full load burn-in test
• LED indicator for power on
• 3 years warranty
General Specification (Please refer to www.meanwell.com for detail spec.)
Mo d el No .
DR-45
AC in p u t vo ltag e ran g e
85~264VAC(DR-45/75, DRP-240); 90~132/180~264VAC selectable by switch (DR-120, DRP-480S); 180~264VAC only (DRP-480)
AC in r u sh cu rr en t (230VAC)
56A
Col d s tart, 40 A at 230VAC
DC ad ju stm en t r an g e
±10%
12V: 12~ 14V, 2 4V: 24~ 28V, 48V: 48~ 5 3V
O ver lo ad p r o tectio n
105% ~ 150% c ons tant c urrent l i m i ti ng, a uto- re c ov ery
O ver vo ltag e
p r o tectio n
DR-75
DR-120
Ran g e
115% ~ 142% rated output v ol tage
Typ e
Shut off, AC rec y c l e to re-s tart
DRP-240
DRP-48 0
45A
DRP-480S
4 0A
45A
30~ 3 6 V for 24V model , 54~ 60V for 48V model
O ver tem p . p ro tectio n
Shut down output v ol tage, rec o v ers auto m ati c al l y af te r tem pe ratu re go es down
With stan d vo ltag e
I/P-O/P: 3k VAC, I/P-F G: 1.5k VAC, O /P-F G : 0 .5k VAC, 1 m i n ute
Wo r kin g tem p er atu re
-10°C~ + 50°C
-10°C~ + 60°C
-10° C~ + 7 0°C
- 20°C~ + 70°C
Safety stan d ard s
UL508, T UV EN60950-1 approv ed (UL6 095 0-1 a l s o for DR-12 0, DRP -240, DRP-480, DRP-480S )
EMC stan d ar d s
EN55022 class B, EN61000-3-2,3, ENV50204, EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 heavy industry level
Co n n ectio n
Dim en sio n (W xHxD)(m m )
I/P: 3 pol es , O/P: 4 pol es sc rew DIN te rm i n al
78x 93x 67
55.5x 125.2x 100
65.5x 12 5.2x 10 0
125 .5 x 125 .2x 100
227x 125.2x 100
Case No .
918A
923
92 1A
922 A
930
Packin g
48pc s / 16.1k g
20pc s / 13.0k g
20p c s / 1 6.5k g
12 pc s / 1 5.5k g
6pc s / 15 .0k g
DR-45 Series
Model No.
DR-4505
DR-4512
DR-4515
DR-4524
DRP-240 Series
Output
5V, 0~5.0A
12V, 0~3.5A
15V, 0~2.8A
24V, 0~2.0A
Tol.
±2%
±1%
±1%
±1%
R&N
100mV
200mV
240mV
480mV
Effi.
72%
77%
77%
80%
Output
12V, 0~6.3A
24V, 0~3.2A
48V, 0~1.6A
Tol.
±2%
±1%
±1%
R&N
100mV
150mV
240mV
Effi.
76%
80%
81%
Model No.
Output
Tol.
R&N
Effi.
DRP-240-24
24V, 0~10A
±1%
80mV
84%
DRP-240-48
48V, 0~5.0A
±1%
150mV
85%
Output
Tol.
R&N
Effi.
DRP-480-24
24V, 0~20A
±1%
120mV
89%
DRP-480-48
48V, 0~10A
±1%
120mV
89%
Tol.
±1%
±1%
R&N
120mV
120mV
Effi.
89%
89%
DRP-480 Series
DR-75 Series
Model No.
DR-75-12
DR-75-24
DR-75-48
6pcs / 16. 6kg
Model No.
DRP-480S Series
DR-120 Series
Model No.
Output
Tol.
R&N
Effi.
DR-120-12
12V, 0~10A
±2%
80mV
80%
DR-120-24
24V, 0~5.0A
±1%
80mV
84%
DR-120-48
48V, 0~2.5A
±1%
100mV
85%
Model No.
DRP-480S-24
DRP-480S-48
We provide specification, drawing, test report and more
information, please visit our website —
http://www.meanwell.com
Output
24V, 0~20A
48V, 0~10A
To satisfy our customers is our goal —
• High Quality
• Low Cost
• Prompt Delivery
• Best Service
24
DIN Series
1 2 0 ~ 9 6 0 W H i g h I n p u t Vo l t a g e
Features
• Input 340~ 550VAC, 3- phas e 4 wi res (si ngl e phase
for DRH- 120)
• Protec ti ons : Short c i rc ui t / O v erl oad / O v er
v ol t age / Ov er temperature
• Bui l t-i n c ons tant c urrent l i mi ti ng c i rc ui t
• Cool i ng by free ai r c onv ec ti on
• Can be i ns tal l ed on DI N rai l T S35 / 7.5 or 15
• UL508 (i ndus tri al c ontrol equi pment) l i s ted
DRH-120
(240~ 960W )
DRT-9 60
DRT-480
DRT-240
• EN61000-6-2 i ndus tri al i mmuni ty l evel
• O pti onal paral l el func ti on (1+ 1) (960W onl y )
• 100% ful l l oad burn-i n t es t
• LED i ndi c ator for power on
• 3 y ears warranty
General Specification (Please refer to www.meanwell.com for detail spec.)
Mo d el No .
DRH-120
DRT-240
340 ~ 550VA C, 3 -p h as e 4 wi res (dual -phas e op erati on pos s i bl e)
AC in p u t vo ltag e r an g e
340~ 550VAC, s i ngl e phas e
AC in r u sh cu r ren t (m ax.)
Col d s tart, 50A at 400VAC
DC ad ju stm en t r an g e
24V: 24~ 28V, 48V: 48~ 55V
O ver lo ad
p r o tectio n
O ver vo ltag e
p r o tectio n
Ran g e
105% ~ 160%
Typ e
Cons tant c urrent l i mi ti ng, au to-rec ov er y
Ran g e
24V: 30~ 36V, 48V: 59~ 66V
Typ e
Shut off, AC rec y c l e to re-s tar t
DRT-480
DRT-960
105% ~ 15 0%
105~ 125%
Co ns tan t c urren t l i mi t i ng, del ay s hu t
off after 3 s ec .
O ver tem p er atu re p ro tectio n
Shut down output v ol tage, rec o v ers auto m ati c al l y af te r tem pe ratu re go es down
With stan d vo ltag e
I/P - O /P: 3k VAC, I/P - F G : 1.5 k VA C, O /P - F G : 0.5k VAC, 1 m i nute
Wo r kin g tem p er atu r e
-20~ + 60°C
-20~ + 70 °C
UL60950-1 approv ed
UL508 , UL609 50-1, T UV EN6 095 0-1 appro v ed
Safety stan d ard s
-20~ + 60°C
EN55022 c l as s B, EN610 00-3 -2 ,3, ENV5020 4, EN61 000- 4-2,3,4 ,5 ,6 ,8,11, EN612 04-3,
EMC stan d ard s
EN61000-6-2 heav y i ndus try l e v el
Co n n ectio n (scr ew DIN term in al) I/P: 3 pol es , O/P: 4 pol es
Dim en sio n (W xHxD)(m m )
65.5x 125.2x 100
I/P: 4 po l e s , O /P : 4 po l e s
I/P: 4 pol e s , O/P: 6 pol es
125 .5x 125.2 x 1 00
2 76x 125.2x 100
227 x 125.2 x 100
Case No .
921
9 22A
930 A
934
Packin g
20pc s / 16.0k g
1 2pc s / 16.6k g
6p c s / 16 .0k g
4pcs / 14.2kg
DRH-120 (Single Phase)
Model No.
Output
DRT-480 (Three Phase)
Tol.
R&N
Effi.
Model No.
Output
Tol.
R&N
Effi.
24V, 0~20A
±1%
80mV
89%
48V, 0~10A
±1%
80mV
90%
DRH-120-24
24V, 0~5.0A
±1%
80mV
85%
DRT-480-24
DRH-120-48
48V, 0~2.5A
±1%
80mV
86%
DRT-480-48
DRT-240 (Three Phase)
DRT-960 (Three Phase)
Model No.
Output
Tol.
R&N
Effi.
Model No.
Output
Tol.
R&N
Effi.
DRT-240-24
24V, 0~10A
±1%
80mV
89%
DRT-960-24
24V, 0~40A
±1%
80mV
91%
DRT-240-48
48V, 0~5.0A
±1%
80mV
89%
DRT-960-48
48V, 0~20A
±1%
80mV
92%
We are a TQM (Total Quality Management) company
and ISO-9001 certified since 1994.
Best products also need best service.
We have authorized distributors all over the world. They have
sufficient stock for your prompt delivery. Also they can offer
you technical support & RMA services. Please contact your
local distributors for more product information. You can also
contact us at info@meanwell.com for information of your local
distributors.
Q.A.
Who can provide you better services and be a trustworthy
partner in the power industry?
— "MEAN WELL" tries to be —
48hrs delivery—
We keep enough stock for 95% of standard models at our
2400m 2 warehouse. We can arrange prompt delivery within
48hrs.
25
DIN Series
120~480W Wide Input Range
De Un
ve der
lop
me
n
Features
• W i de i nput range 180~ 550VAC
t
• Protec ti ons : Short c i rc ui t / Ov erl oad /
Ov er v ol tage / O v er tempe rature
• Cool i ng by free ai r c onv ec ti on
• Bui l t-i n c ons tant c urrent l i mi ti ng c i rcu i t
• Can be i ns tal l ed on DIN rai l T S-35/7.5 or 15
• UL508(i ndus t ri al c ont rol equi pme nt)
• EN61000-6-2(EN50082-2) industrial immunity level
W D R - 1 20
WDR-240
• Bui l t-i n DC O K rel ay c ontac t
W D R - 4 80
• 3 y ears warranty
General Specification (Please refer to www.meanwell.com for detail spec.)
Mo d el No .
WDR-120
AC in p u t vo ltag e r an g e
180~ 550VAC; 254~ 780VDC
AC in r u sh cu r ren t (m ax.)
Col d s tart, 50A at 230VAC
DC ad ju stm en t r an g e
12V: 12~ 15V (onl y for WDR-12 0), 24V: 24 ~ 29V, 48 V: 48~ 58 V
O ver lo ad p r o tectio n
105%~150% rated output voltage, constant current limiting, auto-recovery
O ver vo ltag e
p r o tectio n
O ver tem p er atu r e
p r o tectio n
UL / CUL / TUV / CE pending
W DR-240
WDR-480
Ran g e
16~ 18V for 12V model (onl y for WDR-120 ), 3 1~ 37 V for 2 4V m ode l , 60 ~ 67V for 48V model
Typ e
Shut down o/p v ol tage, re-power on to re c ov er
Ran g e
85 C±5 C (T SW : detect on hea ts i n k of p ower s wi tc h)
Typ e
Shut down output v ol tage, rec ov ers au tom a ti c al l y af te r te mp eratu re goes down
O
O
With stan d vo ltag e
I/P-O/P:3k VAC
Wo r kin g tem p er atu re
-25~ + 70 O C (Refer to output derati n g c u rv e)
I/P-F G :1.5k VA C
O /P-F G :0.5k VA C
Safety stan d ar d s
Des i gn refer to UL508, T UV EN60950 -1
Compl i anc e to EN55011(CISPR11)E N5 5022 Cl as s B, EN610 0 0-4 -2 ,3,4,5,6,8,11, ENV50204, EN61000-6-2
EMC stan d ar d s
(EN50082-2), EN61204-3, heav y i ndu s try l ev el
Co n n ectio n
I/P: 3 pol es , O/P: 4 pol es sc rew DIN te rm i n al
I/P: 3 po l es , O /P : 6 pol e s s c rew DIN termi n al
Dim en sio n (W xHxD)(m m )
40x 125.2x 113.5
63x 1 2 5.2x 11 3.5
120W
WDR-120
Model No.
Tol.
R&N
Effi.
12V, 0~10A
±1.5%
80mV
88%.
WDR-120-24
24V, 0~5A
±1.0%
80mV
89%.
WDR-120-48
48V, 0~2.5A
±1.0%
80mV
89%.
WDR-120-12
Output
240W
WDR-240
Model No.
Output
Tol.
R&N
Effi.
WDR-240-24
24V, 0~10A
±1.0%
120mV
90%.
WDR-240-48
48V, 0~5A
±1.0%
120mV
90%.
480W
WDR-480
Tol.
R&N
Effi.
WDR-480-24
Model No.
24V, 0~20A
±1.0%
100mV
94%.
WDR-480-48
48V, 0~10A
±1.0%
120mV
94%.
Q.A.
Output
Who can provide you better services and be a trustworthy
partner in the power industry?
— "MEAN WELL" tries to be —
To satisfy our customers is our goal —
• High Quality
• Low Cost
• Prompt Delivery
• Best Service
26
8 5.5x 125.2x 128. 5
DIN Series
120~480W Slim and High Efficiency
Features
NEW
• Hi gh eff i c i enc y up t o 94% (SDR-240/4 80 )
NEW
• Uni v ers al AC i nput / F ul l range
• Bui l t-i n ac ti v e PF C f unc t i on
• Protec ti ons : Short c i rc ui t / Ov erl oad /
Ov er v ol tage / O v er tempe rature
• Cool i ng by free ai r c onv ec ti on
• Can be i ns tal l ed on DIN rai l T S-35/7.5 or 15
• UL508(i ndus t ri al c ont rol equi pme nt) appro ved
• EN61000-6-2(EN50082-2) industrial immunity level
• Bui l t-i n DC O K rel ay c ontac t
• 150% peak l oad c apabi l i ty
S D R - 480 P
S D R - 24 0
S D R - 1 20
• Compl y wi th G L and SEM I F 47
• O pti onal c urr ent s hari ng (7+ 1) (SDR-480P )
• 3 y ears warranty
GL
General Specification (Please refer to www.meanwell.com for detail spec.)
SE
PQ
M
IF
47
Marine
Mo d el No .
SDR-120 NEW
S DR-240
SDR-480
AC in p u t vo ltag e r an g e
88~ 264VAC; 124~ 370VDC
AC in r u sh cu r ren t (m ax.)
Col d s tart, 70A at 230VAC
DC ad ju stm en t r an g e
12V: 12~ 14V (onl y for SDR-120), 2 4V: 2 4~ 28 V, 48V: 48~ 5 5V
NEW
90~ 264VAC; 127~ 370VDC
Co l d s tart, 65A at 23 0VAC
Col d s tart, 80A at 230VA C
Normally works within 110 ~ 150% rated output power for 3 seconds and then shut down output voltage with auto-recovery
O ver lo ad p ro tectio n
> 150% rated power or s hort c i rc u i t, c ons tan t c urre nt l i m i ti ng wi th auto -rec ov ery wi thi n 2 s ec onds and may cau s e
to s hut down i f ov er 2 s ec onds
Over voltage
protection
Over
temperature
protection
Ran g e
14~ 17V for 12V model (SDR-120 onl y ), 29 ~ 3 3V fo r 24 V mo del , 56~ 6 5V for 48V mode l
Shut down o/p v ol tage, re-power on
Typ e
Sh ut down o/p v ol ta ge wi th auto-re c o v ery
to rec ov er
O
O
95 C±5 C (T SW : detec t on heats i nk of pow er s wi tc h)
Typ e
Shut down output v ol tage, rec o v ers auto m ati c al l y af te r tem pe ratu re go es down
With stan d vo ltag e
I/P-O/P:3k VAC
I/P-F G:1.5k VAC
O /P-F G :0.5k VAC
O
105 C±5 C
O
Ran g e
(TSW : detect on heatsink of power switch)
O /P-DC O K :0.5k VAC
O
Wo r kin g tem p er atu r e
-25~ + 70 C (Refer to output derati ng c u rv e)
Safety stan d ar d s
UL508, T UV EN60950-1, GL approv ed (SDR-12 0 an d SD R-48 0 pend i ng)
Compl i anc e to EN55022 Cl as s B, EN61 000-4-2,3,4,5 ,6,8,11, ENV502 04, EN61000-6-2 (EN5008 2-2), E N61204-3,
EMC stan d ar d s
heav y i ndus try l ev el , SEMI F 47, G L
Co n n ectio n
I/P: 3 poles, O/P: 4 poles screw DIN terminal
I/P: 3 poles, O/P: 6 poles screw DIN terminal I/P: 3 poles, O/P: 8 poles screw DIN terminal
Dim en sio n (W xHxD)(m m )
40x 125.2x 113.5
63x 1 2 5.2x 11 3.5
120W
NEW
85.5x 125.2x 128.5
480W
SDR-120
NEW
SDR-480
Model No.
Output
Tol.
R&N
Effi.
Tol.
R&N
Effi.
SDR-120-12
12V, 0~ 10A
±1.0%
100mV
89 %
SDR-48 0
-2 4
2 4V, 0~ 20 A
±1.0%
100m V
94%
SDR-120-24
24V, 0~ 5A
±1.0%
100mV
91%
SDR-48 0
-4 8
4 8V, 0~ 10 A
±1.0%
120m V
94%
SDR-120-48
48V, 0~ 2.5A
±1.0%
120mV
90%
240W
Output
= b l ank , P ; Bl an k : bas i c fu nc ti on, P : wi th p ar al l el func ti on
SDR-240
Model No.
Output
Tol.
R&N
Effi.
SDR-240-24
24V, 0~ 10A
±1.0%
100mV
94 %
SDR-240-48
48V, 0~ 5A
±1.0%
120mV
9 4%
►
►Feature
Model No.
We provide specification, drawing, test report and more
information, please visit our website —
http://www.meanwell.com
Description
SDR family is our new slim DIN rail product series targeting at the growing demand of high performance DIN rail power supply in the market.
Featuring up to 94% of extreme high efficiency, they can provide 120W, 240W, or 480W continuously and 150% peak power for 3 seconds up to
60 O C by only free air convection. The slim design of 40mm(SDR-120) / 63mm(SDR-240) / 85.5mm(SDR-480) in width helps save the precious space
on the rail and also makes it 30.7%, 43% and 51.6% smaller in size compare to its predecessor model. To fulfill the requirements of marine and
semi-conductor related usage, the SDR family complies with GL and SEMI F47 norms in addition to UL, CUL, TUV, and CE certificates.
27
DIN Series
Peri pheral M odul e
40A DC UPS Module
20A Power Supply Redundant Module
• Battery controller for DIN rail UPS
system
• Parallel connected to DC BUS
• Suitable for 24V system up to 40A
• Installed on DIN Rail TS35 / 7.5 or 15
• Built-in battery test function
• Battery polarity protection
• Relay contact signal output and LED
indicator for DC BUS OK, Battery Fail,
and Battery Discharge
• Cooling by free air convection
• 3 years warranty
• Suitable for redundant operation of
24V system
CASE: 923C
55.5x 125.2x 100 mm
• Installed on DIN rail TS35 / 7.5 or 15
• Relay contact signal output and LED
indicator for input failure alarm
• Cooling by free air convection
• 3 years warranty
CASE: 923D
DC input voltage range ....... 21~28V, 20A max. x 2 channels
Reverse voltage ................ 30V
DC output current .............. 20A max.
DC output voltage drop ...... 0.5V max.
Input voltage alarm ............ When input is > 20V(±5%) or <30V(±5%),
relay contacts
Relay contact rating ........... 30VDC, 1A
Working temperature ......... -20~+70 O C
EMC standards ................. EN55022 class B, EN61000-4-2,3,4,5,6,8,
ENV50204
Connection ....................... I/P: 4 poles, O/P: 2 poles screw DIN terminal,
Single output: 4 poles
Packing ............................ 0.5Kg ; 20pcs / 11Kg / 1.29CUFT
Model No.
Output
DR-RDN20
24V, 20A
►
►Feature
Reverse Voltage
Current
30V max.
20A max.
55.5x 125.2x 100 mm
DC input / DC bus ............. 24~29V, 40A max.
Battery input voltage ......... 21~29V
Battery input Current ......... 0~40A
Charge current (typ.) ......... 2A
External battery (typ.) ....... 24V, 4AH / 7AH / 12AH
DC bus ok ........................ Relay status : Short when DC voltage between
21~29V(±3%), relay contacts
LED(Green) : DC bus OK : light;
DC bus fail : dark
Battery fail ....................... Relay status : Short when battery failure is
observed through the battery
test function, relay contacts
LED(Red) :
Battery over-discharge warning
or battery broken: light;
Battery OK: dark
Battery discharge ............. Relay status : Short when battery in discharge
condition, relay contacts
LED(Yellow) : Battery discharging: light;
Battery is not discharging or
discharging current <2A: dark
Working temperature ......... -20~+70 O C
EMC standards ................. EN55022 class B, EN61000-4-2,3,4,5,6,8,
ENV50204
Connection ...................... I/P: 2 poles, O/P: 2 poles screw DIN terminal,
Single output: 6 poles
Packing ............................ 0.55Kg ; 20pcs / 12Kg / 1.29CUFT
Description
DR-RDN-20 is a 20A redundancy (decoupling) module for the 24Vdc
power system. Containing 2 sets of 20A Or-ing diodes with wonderful heat
dissipation deployment, DR-RDN20 offers a safe option of 1+1 redundant
set-up. Not only perfectly decouple power sources from each other as well
as from the load, DR-RDN-20 also provides users monitoring signals for
both input channels through the built-in relays.
DR-UPS40 is a 40A max. DC UPS (battery control) module for the 24Vdc
power system. Accompany with external batteries, it can back-up up to
40A of current to critical loads for certain period of time depending on the
capacity of batteries. With complete monitoring signals / LED indicators for
DC BUS OK, Battery Fail, Battery Discharge, and the repeated Battery Test
function to check the situation of external batteries, users can customize
their own DC UPS system to back up critical loads and capture the status
of the whole system easily.
Model No.
DC BUS Voltage
DC BUS Current
DR-UPS40
24~29V
40A max.
Block Diagram
25Ax2
LOAD
Block Diagram
+
Vout +
B2
Detector
B
Com
+
CHARGE
CIRCUIT
LIMIT
INPUT
+
POWER
SUPPLY
Alarm B
24V
BATTERY
BAT.
TEST
B1
Vin B+
A2
Detector
A
+
DETECTION
CIRCUIT
Alarm A
A1
Vin A+
DR-UPS40
DC
OK
BAT
BAT
FAIL DISCHARGE
Example of Application
Example of Application
24V
PSU
Back up connection for
AC interruption
24V
PSU
DR-UPS40
24V
Battery
DR-RDN20
1+1 Redundancy :
Using 1 more PSU as the redundant unit
Vout
+
Load
28
-
BAT
+ -
DIN Rail
Power
24V
Load
DC
-
+
+
-
+
-
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising