2016-35-140 Downconverter, 3.4 - 4.2 GHz, 140 MHz IF

2016-35-140 Downconverter, 3.4 - 4.2 GHz, 140 MHz IF
DATA SHEET
CROSS TECHNOLOGIES, INC.
REV. 0
2/20/13
2016-35-140 Downconverter, 3.4 - 4.2 GHz, 140 MHz IF
The 2016-35-140 Downconverter converts 3.4 to 4.2 GHz to 140 ± 36 MHz in 125 kHz steps (1 kHz steps, option X1005) with low group
delay and flat frequency response. Synthesized local oscillators (LO) provide low phase noise and ±0.01 ppm stability frequency selection.
Push button switches select the RF frequency, gain, and other parameters. Front panel LEDs provide indication of DC power (green), PLL
alarm (red), and remote operation (yellow). Gain is adjustable manually over a +30 to +50 dB range as adjusted by the front panel multifunction push-button switches. Remote operation allows selection of frequency and gain. Parameter selection and frequency and gain
settings appear on the LCD display. Connectors are BNC (female) for IF output and the 10MHz reference input and output, and Type N
(female) for the RF input. External 10 MHz is standard. A 10 MHz output connector contains either the internal or external 10 MHz
reference signal. Unit is powered by a 100-240 ±10% VAC power supply, and housed in a 1 3/4” X 19“ X 16” rack mount chassis.
MODEL 2016
DOWNCONVERTER
F = 3750.125
G = +30.0
MENU
CROSS TECHNOLOGIES INC.
EXECUTE
ALARM
REMOTE
POWER
Front Panel
EQUIPMENT SPECIFICATIONS*
Input Characteristics (RF)
Impedance/Return Loss 50Ω/20 dB typ; 18 dB min.
3.4
140
VAR
VAR
to
MHz
ATT
ATT
Frequency
3.4 to 4.2 GHz
4.2
OUT
GHz
Noise Figure, max.
15 dB (max gain)
IN
EXT
Level
-70 to -30 dBm
10 MHz*
Output Characteristics (IF)
Impedance/Return Loss 75Ω /20 dB typ., 18 dB min.
INT
10 MHz
Frequency
140 ± 36 MHz
F=3750.125
Level
-20 to 0 dBm
CONTROLLER
G=+30.0
1dB compression
+10 dBm
Channel Characteristics
Block Diagram
Gain range (adjustable) +30 to +50 dB, 0.5 ±0.5 dB steps
Image Rejection
> 50 dB, min
Spurious Response
<-55 dBC, typical;<-50 dBC, maximum
Frequency Response
±1.5 dB, 3.4-4.2 GHz ; ± 0.7 dB, 72 MHz BW
Available Options
Group Delay, max
0.0035 ns/MHz2 parabolic; 0.025 ns/MHz linear, 1 ns ripple
W7 - RF/IF Monitor Ports (Front)
Frequency Sense
Non-inverting
W31 - Ext. Temp 0C to +50C
Synthesizer Characteristics
X1005 - 1 kHz frequency step
Frequency Accuracy
± 0.01 ppm internal reference; external reference input
Remote M&C Interfaces:
Frequency Step
125 kHz minimum; (1 kHz steps, option X1005)
Q - RS485/422
10 MHz In/Out Level
3 dBm ± 3 dB
W8 - Ethernet; w/Web Browser (WB)
Phase Noise @ F (Hz) >
10
100
1K
10K
100K
1M
W18 - Ethernet; w/WB & SNMP
Standard-125kHz steps: dBC/Hz
-55
-70
-75
-80
-95
-105
W28 - Ethernet; w/TCP/IP, Telnet
X1005-1kHz steps: dBC/Hz
-60
-75
-85
-90
-105
-120
Connectors/Impedance
Controls, Indicators
STD. - 50Ω Type N (RF), 75Ω BNC (IF)
Freq/Gain Selection
direct readout LCD; pushbutton switches or remote selection
M - 50Ω Type N (RF), 50Ω BNC (IF)
Power; Alarm; Remote
Green LED; Red LED; Yellow LED
S - 50Ω SMA (RF), 50Ω BNC (IF)
Remote
RS232C, 9600 baud; RS485/422 or Ethernet optional
S7 - 50Ω SMA (RF), 75Ω BNC (IF)
Other
RF / IF Connectors
RF - Type N (female) / IF - BNC (female)
10 MHz Connectors
BNC (female), 75Ω, works with 50 or 75 ohms
Alarm/Remote Connector DB9 - NO or NC contact closure on Alarm
Size
19 inch, 1RU standard chassis 1.75” high X 16.0” deep
Power
100-240 ± 10% VAC, 47-63 Hz, 45 watts max
*10˚C to 40˚C; Specifications subject to change without notice
Cross Technologies, Inc.
•
6170 Shiloh Road • Alpharetta, GA 30005
www.crosstechnologies.com
• 770.886.8005 • FAX 770.886.7964
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project