K-2355 ARCHER VITREOUS CHINA UNDERCOUNTER LAVATORY CUT-OUT TEMPLATE / INSTALLATION INSTRUCTION

K-2355 ARCHER VITREOUS CHINA UNDERCOUNTER LAVATORY CUT-OUT TEMPLATE / INSTALLATION INSTRUCTION
NOTE: before cutting countertop
Allow for handle clearance
FINISHED WALL / BACK SPLASH
50mm
CENTERLINE OF FITTING
63.5mm
K-2355
ARCHER
VITREOUS CHINA UNDERCOUNTER LAVATORY
CUT-OUT TEMPLATE / INSTALLATION INSTRUCTION
INSTALL THE LAVATORY
BEFORE YOU BEGIN
· Due to the nature of the installation, undercounter lavatories
should be installed by trained and experienced installers.
· Do not use adhesives or adhesive sealants with this product.
· Inspect the waste and supply tubing; replace if necessary.
· Prior to installation, unpack the new lavatory and inspect it for
damage. Return the lavatory to its protective carton until you
are ready to install it.
· Observe all local plumbing and building codes.
· Kohler lavatory is made according to American National Standard
that it can match the American lavatory fittings . Any other lavatory
fittings may not fit for kohler lavatory.
·
CLIP LOCATIONS
·
·
·
·
·
·
·
·
·
·
·
·
·
·
NOTE: Install so future removal from underneath the
countertop is possible to avoid damage to the
countertop.
·
· Check the desired lavatory location for clearance
between the backsplash, faucet, fixture, and cabinet.
· Cut out the template.
· Carefully position and trace the template on the
countertop as directed on the template.
· Mark the faucet hole centerline on the countertop.
· Drill a 13mm(1/2") pilot hole on the inside of the cut line.
· Cut out the countertop opening with a saber or keyhole
saw.
·
·
·
·
·
13
(1/2")
TOOLS AND MATERIALS
(
13
(1/2")
· Sealant
· Pencil
· Tape measure
· Sharp knife or scissors
· Keyhole or saber saw
· Drill (13mm(1/2") dia. drill bit or larger)
· Safety glasses
· Hammer
· Rags or paper toweling
NOTE: You may require different, more specialized tools to install this
lavatory to countertop materials other than wood or wood composites.
)
329.3mm
FOR WOOD COUNTERTOPS
· Mark and pre-drill the wood screw holes at the locations
shown on the template.
· Waterproof any exposed areas of wood.
·
·
Setting Tool
·
Marble
10
·
(3/8")
16
(5/8")
Anchor
ó
Foam
Padding
·
·
C
L of Fitting
·
610mm
76mm
10mm
·
256mm
192mm
Clamp
16mm
389mm
Sealant
203mm
Min
813mm
864mm
249mm
29mm
498mm
686mm
Min
11mm
Sealant
Wood
Marble
152mm
Max
·
Apply Sealant
25
Installation
Anchor Screw
(1")
Wood Screw
229mm
Min
·
191mm
356mm
Recommended ADA Installation
ADA
333mm
3/8 Hot
Note: Waterproof unprotected overhang
area on the underside of wood counter.
3/8 Cold
·
1-1/4 Qutlet
·
·
102mm
·
Roughing-In Notes
(ASME)A112.19.2M
*
K-8998
25
(1")
25
(1")
· Position the countertop upside down on foam padding to
protect the surface. Mark and drill 10mm(3/8") holes
16mm(5/8") deep at the locations shown on the template.
· Use a setting tool and hammer to secure the anchors.
FOR ALL INSTALLATIONS
ROUGH-IN
64mm
FOR MARBLE COUNTERTOPS
Fixture dimensions are nominal and conform to tolerances in ASME Standard A112.19.2M.
*Based on K-8998 with 25mm(1") of tailpiece exposed.
(
· If the countertop has not been installed, install it at this
time.
· Drill the faucet holes according to the faucet installation
instructions.
· Install the faucet to the countertop according to the
manufacturer s instructions.
· Install the drain to the lavatory according to the
manufacturer s instructions.
NOTE: Do not use adhesives or adhesive sealants.
· Apply a continuous bead of quality sealant to the
lavatory rim where it will contact the countertop.
NOTE: The screws provided should be used on countertops
with a minimum 25mm(1") thickness. For thinner
countertops, use appropriate anchors and fasteners.
· For wood, wood composite, and marble countertops,
install the lavatory to the countertop with the clamps and
screws provided. For other countertop materials, refer to
the countertop manufacturer s instructions for
recommended fasteners.
· Position the lavatory squarely under the cutout before
tightening the clamps. Draw the lavatory rim up to the
countertop until it is snug. Do not overtighten.
· Immediately wipe away any excess sealant.
· Make the final drain and faucet connections to complete
the lavatory installation. Be sure to follow all instructions
packed with the drain and faucet.
· Clean up with a non-abrasive cleaner.
IMPORTANT CONSUMER
INFORMATION (CARE AND CLEANING)
)
Supplied basin clamp assemblies require 25mm(1")
minimum countertop thickness. Installer must supply
anchors for thinner countertops.
To keep your lavatory looking new, make sure you rinse it out thoroughly
after each use. DO NOT USE ABRASIVES on this product, as they will
scratch and ruin the surface. Stubborn stains, paint, or tar can be removed
with turpentine or paint thinner.
CUT ALONG THIS LINE
RIM OF LAVATORY
6mm
NOTE: Using this template, the
overhung is about 6mm. Customers can
zoom the template by scale to meet
their requirement.
1080825-T01-A
106
443.6mm
2
324
200131
117215-T01-C
, 2007
ã
ã Copyright Kohler China Ltd., 2007
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising