UCS 50
riešenia na presné meranie
P.O. Box 27
4300 AA Zierikzee
The Netherlands
Tel. +31 111 413656
Fax. +31 111 416919
www.deltapowersupplies.com
DELTA ELEKTRONIKA B.V.
UCS 50 B
UCS 50
U - Series
UCS 50 CONSTANT CURRENT SOURCE
Models
Voltage range
Current range
UCS 50 (current source)
30 V
0 - 50 mA
• Input
• Transformer
: 230 / 115 V AC 48 - 62 Hz
: Split bobbin, potted, safety transformer
According to,VDE0551, EN60742
• Ripple + noise
• Test voltage
Input / Output
Input / Case
Output / Case
: 4000 Vrms (output case shorted)
: 4000 Vrms (output case shorted)
: 500 VDC
• Input to output
Leakage current
Coupling capacitance
Insulation resistance
Attenuation input spikes
• Output impedance
DC
• 1 kHz
• 10 kHz
• 100 kHz
: 10 MOhm
: 33 kOhm
: 3.3 kOhm
: 0.33 kOhm
: Typical 5 µA
: Less than 60 pF
: 1000 MOhm
: Better than 100 dB
• Recovery time
600 - 60 Ohm
Open voltage limit
Ambient temperature
: 10 µs
: 33 V +/- 5%
: -20 to +50 °C
• Current adjustment
• Programming input
• Current regulation
Load 600 - 0 Ohm
Line =/- 10 %
• Temperature coeff.
• Stability
: 0-50 mA
: By a 20-turn screwdriver adjustment
: By external potmeter 10 kΩ
: By 0-5 V analog programming
• Accessories
: 30 µA pp, measured
across 600 Ohm // 0.1 µF
: 0.005% per °C
: 0.01% per 8 hrs after 20
min warm up.
: P500 Eurocard for 2 units
Front panel F10-3 for P500.
For more details see also
U-series
: 0-5 V, full scale error ± 0.2%, offset error ≤ 20 µA
: Input impedance 500 kOhm.
Derating of max.
voltage at low
line voltage
: 3 µA
: 3 µΑ
Dimensions and Weight
• Height
: 35 mm
• Weight
: 0.4 kg
• Width
: 58 mm
• Depth
: 94 mm
UCS 50 with solder pins for PCB mounting
UCS 50 B with screw terminals for
mounting
wall or rail
http://www.elso.sk
Clamp for
rail mounting
Was this manual useful for you? yes no