- No category
advertisement
R64G - Olympian Plus plug-in system
Pressure regulator
> Port size: 1/4” ... 3/4”
(ISO G/PTF)
> Non-rising adjusting knob has snap-action lock
> Diaphragm and balanced valve design ensure good regulation characteristics
Technical features
Medium:
Compressed air only
Maximum operating pressure:
17 bar (246 psi)
Pressure range:
(standard)
0,3 ... 10 bar (4 ... 145 psi)
(optional)
0,4 ... 4 bar ( 5 ... 58 psi),
0,7 ... 17 bar (10 ... 246 psi)
Port sizes:
1/4”, 3/8”, 1/2” or 3/4”
Gauge port:
1/8 PTF with PTF main ports
Rc1/8 with ISO G main ports
Flow:
See table below
Relieving:
With (standard)
Non-relieving (optional)
Ambient/Media temperature:
-20° ... +80°C (-4° ... +176°F)
Version with gauge:
-20° ... +65°C (-4° ... +149°F)
Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F).
Materials:
Body and yoke: Zinc alloy
Connection piece: Aluminium
Bonnet: Aluminium
Adjusting knob: Acetal resin
Elastomers: NBR
Technical data, standard models with relieving
Symbol Port size Size
G1/4
G3/8
G1/2
G3/4
—
—
Basic
—
Without yoke —
Pressure range
(bar)
0,3 ...10
0,3 ...10
0,3 ...10
0,3 ...10
0,3 ...10
Flow *
(dm 3 /s)
35
80
120
120
Adjustment
Knob
Knob
Knob
Knob
Knob
* Typical flow with 10 bar (145 psi) inlet pressure, and 6,3 bar (91 psi) set pressure and 1 bar (14.5 psi) drop from set.
Weight
(kg)
1,63
1,61
1,59
1,87
1,16
Model
R64G-2GK-RMN
R64G-3GK-RMN
R64G-4GK-RMN
R64G-6GK-RMN
R64G-NNK-RMN
Option selector
Port size
1/4”
3/8”
1/2”
3/4”
Without yoke
Thread
PTF
ISO G (standard)
Without yoke (standard)
Adjustment
Knob (standard)
T-bar (0,7 ... 17 bar)
Substitute
2
3
4
Substitute
A
6
N
Substitute
K
G
N
T *2)
R64G-˙˙˙-˙˙˙
Gauge
Wi h
Wi hout (standard)
Pressure range (bar) *1)
0,3 ...10 (standard)
0,3 ... 4
0,7 ... 17
Diaphragm
Relieving (standard)
Non-relieving
Substitute
G
N
Substitute
S*2)
Substitute
M
F
R
N
*1) Outlet pressure can be adjusted to pressures in excess of and less than, those specified. Do not use these units to control pressures outside of the specified ranges.
*2) Units with 17 bar (246 psi) outlet pressure range are available only with the
T-bar adjustment; therefore substitute T at the 7th digit and S at the 9th position.
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (1998 - 8078c) © 2015 IMI International s.r.o.
5/15 en 8.240.200.01
R64G - Olympian Plus plug-in system
Pressure regulator
Flow characteristics
Inlet pressure: 10 bar, port size: 1/2”
Pressure range: 0,3 ... 10 bar bar
6
5
4
3
8
7
2
1
0
0 30 60 90
Air flow
120
Accessories, service kit and gauges
150 dm 3 /s
4
8
Regulating characteristics
Port size: 1/2”
9
8
4
3
7
6
5
1,5 l / s
15,4 l / s
10,2 l / s
2
1
0
0
0,7 l / s
2
2,9 l / s
29,3 l / s
2,3 l / s
4
23,4 l / s
30,8 l / s
7,1 l / s
6
1 l / s
20,4 l / s
14,2 l / s
8
46,8 l / s
Inlet pressure
58,6 l / s
10 12 14 bar
5
2
6
1
3
Accessories
Models with G-thread
Single yoke Double yoke
3/2 Shut-off valve
Threaded inlet only Threaded outlet only
End connector kit
Rear entry bracket kit
Thread
G1/4
G3/8
G1/2
G3/4
1/4 PTF
3/8 PTF
1/2 PTF
3/4 PTF
5
Y64A-2GA-N1N
Y64A-3GA-N1N
Y64A-4GA-N1N
Y64A-6GA-N1N*
Y64A-2AA-N1N
Y64A-3AA-N1N
Y64A-4AA-N1N
Y64A-6AA-N1N*
Y64A-2GA-N2N
Y64A-3GA-N2N
Y64A-4GA-N2N
Y64A-6GA-N2N*
Y64A-2AA-N2N
Y64A-3AA-N2N
Y64A-4AA-N2N
Y64A-6AA-N2N*
*These yokes are supplied with two end connenctor kits as standard.
en 8.240.200.02
T64T-2GB-P1N
T64T-3GB-P1N
T64T-4GB-P1N
T64T-6GB-P1N
T64T-2AB-P1N
T64T-3AB-P1N
T64T-4AB-P1N
T64T-6AB-P1N
T64T-2GC-P1N
T64T-3GC-P1N
T64T-4GC-P1N
T64T-6GC-P1N
T64T-2AC-P1N
T64T-3AC-P1N
T64T-4AC-P1N
T64T-6AC-P1N
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (1998 - 8078c) © 2015 IMI International s.r.o.
—
—
74505-50
74505-53
—
—
74505-52
74505-55
8
—
—
—
18-026-981
—
—
—
—
5/15
Bracket mounting Nut
1
74504-50
30 3
4
74502-89
R64G - Olympian Plus plug-in system
Pressure regulator
Tamper resistant cap & seal wire
Yoke connector kit Porting block Adjustable pressure switch
Padlock with two keys
3
4355-51
9
74503-51 74507-50 4346-99 0613633 (brass)
R64G-KITR (for relieving version)
Gauges
Center back connection, white face
(full technical specification see datasheet
8.900.900)
6
Pressure range bar *1 MPa psi
0 ... 4
0 ... 10
0 ... 0,4 0 ... 58
0 ... 1 0 ... 145
50 mm
50 mm
0 ... 25 0 ... 2,5 0 ... 362 50 mm
*1) primary scale
R1/8
R1/8
12 1 14
18-013-013
Center back connection, black face for North America (full technical specification see datasheet
8.900.900)
6
Pressure range psig *1 bar MPa Ø Thread size Model
0 ... 60 0 ... 4 0 ... 0.4
2” (50 mm)
0 ... 160 0 ... 11 0 ... 1.1
2” (50 mm)
0 ... 400 0 ... 28 0 ... 2.8
2” (50 mm)
*1) primary scale
1/8 NPT
1/8 NPT
1/8 NPT
18-013-202
18-013-204
18-013-206
5/15
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (1998 - 8078c) © 2015 IMI International s.r.o.
en 8.240.200.03
R64G - Olympian Plus plug-in system
Pressure regulator
Basic dimensions
Standrad T-bar
5 or 3/16”
7
3
ø 47
157
105
1 15 1
Single yoke with bracket mounting
143
114
2,8
14,5
14,5
2,8
57 80
Dimensions in mm
Projection/First angle
66
# Minimum clearance required to remove unit from yoke
1 Main ports 1/4”, 3/8”, 1/2” or 3/4”
3
5
For main ports 3/4” only
Reduces by 4 mm with knob in locked position
7 Gauge port
Double yoke with bracket mounting
223
194 en 8.240.200.04
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (1998 - 8078c) © 2015 IMI International s.r.o.
5/15
Rear entry bracket
18-026-981
A A
20,5
41,5
8 +0,2 7,5
83,5
54,5
A-A
1
1 ‘O’-ring (included in scope of supply of bracket)
2
Adjustable pressure switch
4346-99
Voltage
Current
Pressure range
Repeatabillity
Average deadband
Electrical connection
(corresponding to choosen coil)
Degee of protection:
Adjustable
Material
24 V d.c./240 V a.c.
0,5 A (d.c.); 5 A (a.c.)
2 ... 10 bar
2% of full set point range at 20°C
0,8 ... 1,7 bar
EN 175301-803 - Form C, 15 mm
IP65
Standard
Body: Aluminium, Elastomers: NBR
3/2 Shut-off valve
Symbol
2
1 3
A
G1/4
G3/8
G1/2
G3/4
B
48
48
48
51
* B = Threaded inlet only, C = Threaded outlet only
ø C
27
27
27
33
Model
T64T-2G*-P1N
T64T-3G*-P1N
T64T-4G*-P1N
T64T-6G*-P1N
R64G - Olympian Plus plug-in system
Pressure regulator
Porting block
74507-50
Dimensions in mm
Projection/First angle
59
41
ø 22
G3/8
Pg 7
G1/4
7
73
OPEN
59 ø 22
41
6 Adjusting screw
B
6
Rc 1/8
17
7 Padlock hole 7,5 mm
27,5
13,5
Warning
These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under
»Technical features/data«.
Before using these products with fluids other than those specified, for non-industrial applications, life-support systems or other applications not within published specifications, consult IMI NORGREN.
Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes.
The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure.
System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided.
System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products.
5/15
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (1998 - 8078c) © 2015 IMI International s.r.o.
Diese Produkte sind ausschließlich in Druckluftsystemen zu verwenden.
Sie sind dort einzusetzen, wo die unter »Technische Merkmale/-
Daten« aufgeführten Werte nicht überschritten werden.
Berücksichtigen Sie bitte die entsprechende Katalogseite. Vor dem
Einsatz der Produkte bei nicht industriellen Anwendungen, in lebenserhaltenden- oder anderen Systemen, die nicht in den veröffentlichten
Anleitungsunterlagen enthalten sind, wenden Sie sich bitte direkt an
IMI NORGREN.
Durch Missbrauch, Verschleiß oder Störungen können in Pneumatiken 8.240.200.05
systemen verwendete Komponenten auf verschiedene Arten versagen.
Systemauslegern wird dringend empfohlen, die Störungsarten aller in Pneumatiksystemen verwendeten Komponententeile zu berücksichtigen und ausreichende Sicherheitsvorkehrungen zu treffen, um
Verletzungen von Personen sowie Beschädigungen der Geräte im
Falle einer solchen Störung zu verhindern.
Systemausleger sind verpflichtet, Sicherheitshinweise für den Endbenutzer im Betriebshandbuch zu vermerken, wenn der Störungsschutz nicht ausreichend gewährleistet ist.
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project