R64G - Olympian Plus plug-in system

Pressure regulator

> Port size: 1/4” ... 3/4”

(ISO G/PTF)

> Non-rising adjusting knob has snap-action lock

> Diaphragm and balanced valve design ensure good regulation characteristics

Technical features

Medium:

Compressed air only

Maximum operating pressure:

17 bar (246 psi)

Pressure range:

(standard)

0,3 ... 10 bar (4 ... 145 psi)

(optional)

0,4 ... 4 bar ( 5 ... 58 psi),

0,7 ... 17 bar (10 ... 246 psi)

Port sizes:

1/4”, 3/8”, 1/2” or 3/4”

Gauge port:

1/8 PTF with PTF main ports

Rc1/8 with ISO G main ports

Flow:

See table below

Relieving:

With (standard)

Non-relieving (optional)

Ambient/Media temperature:

-20° ... +80°C (-4° ... +176°F)

Version with gauge:

-20° ... +65°C (-4° ... +149°F)

Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F).

Materials:

Body and yoke: Zinc alloy

Connection piece: Aluminium

Bonnet: Aluminium

Adjusting knob: Acetal resin

Elastomers: NBR

Technical data, standard models with relieving

Symbol Port size Size

G1/4

G3/8

G1/2

G3/4

Basic

Without yoke —

Pressure range

(bar)

0,3 ...10

0,3 ...10

0,3 ...10

0,3 ...10

0,3 ...10

Flow *

(dm 3 /s)

35

80

120

120

Adjustment

Knob

Knob

Knob

Knob

Knob

* Typical flow with 10 bar (145 psi) inlet pressure, and 6,3 bar (91 psi) set pressure and 1 bar (14.5 psi) drop from set.

Weight

(kg)

1,63

1,61

1,59

1,87

1,16

Model

R64G-2GK-RMN

R64G-3GK-RMN

R64G-4GK-RMN

R64G-6GK-RMN

R64G-NNK-RMN

Option selector

Port size

1/4”

3/8”

1/2”

3/4”

Without yoke

Thread

PTF

ISO G (standard)

Without yoke (standard)

Adjustment

Knob (standard)

T-bar (0,7 ... 17 bar)

Substitute

2

3

4

Substitute

A

6

N

Substitute

K

G

N

T *2)

R64G-˙˙˙-˙˙˙

Gauge

Wi h

Wi hout (standard)

Pressure range (bar) *1)

0,3 ...10 (standard)

0,3 ... 4

0,7 ... 17

Diaphragm

Relieving (standard)

Non-relieving

Substitute

G

N

Substitute

S*2)

Substitute

M

F

R

N

*1) Outlet pressure can be adjusted to pressures in excess of and less than, those specified. Do not use these units to control pressures outside of the specified ranges.

*2) Units with 17 bar (246 psi) outlet pressure range are available only with the

T-bar adjustment; therefore substitute T at the 7th digit and S at the 9th position.

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (1998 - 8078c) © 2015 IMI International s.r.o.

5/15 en 8.240.200.01

R64G - Olympian Plus plug-in system

Pressure regulator

Flow characteristics

Inlet pressure: 10 bar, port size: 1/2”

Pressure range: 0,3 ... 10 bar bar

6

5

4

3

8

7

2

1

0

0 30 60 90

Air flow

120

Accessories, service kit and gauges

150 dm 3 /s

4

8

Regulating characteristics

Port size: 1/2”

9

8

4

3

7

6

5

1,5 l / s

15,4 l / s

10,2 l / s

2

1

0

0

0,7 l / s

2

2,9 l / s

29,3 l / s

2,3 l / s

4

23,4 l / s

30,8 l / s

7,1 l / s

6

1 l / s

20,4 l / s

14,2 l / s

8

46,8 l / s

Inlet pressure

58,6 l / s

10 12 14 bar

5

2

6

1

3

Accessories

Models with G-thread

Single yoke Double yoke

3/2 Shut-off valve

Threaded inlet only Threaded outlet only

End connector kit

Rear entry bracket kit

Thread

G1/4

G3/8

G1/2

G3/4

1/4 PTF

3/8 PTF

1/2 PTF

3/4 PTF

5

Y64A-2GA-N1N

Y64A-3GA-N1N

Y64A-4GA-N1N

Y64A-6GA-N1N*

Y64A-2AA-N1N

Y64A-3AA-N1N

Y64A-4AA-N1N

Y64A-6AA-N1N*

Y64A-2GA-N2N

Y64A-3GA-N2N

Y64A-4GA-N2N

Y64A-6GA-N2N*

Y64A-2AA-N2N

Y64A-3AA-N2N

Y64A-4AA-N2N

Y64A-6AA-N2N*

*These yokes are supplied with two end connenctor kits as standard.

en 8.240.200.02

T64T-2GB-P1N

T64T-3GB-P1N

T64T-4GB-P1N

T64T-6GB-P1N

T64T-2AB-P1N

T64T-3AB-P1N

T64T-4AB-P1N

T64T-6AB-P1N

T64T-2GC-P1N

T64T-3GC-P1N

T64T-4GC-P1N

T64T-6GC-P1N

T64T-2AC-P1N

T64T-3AC-P1N

T64T-4AC-P1N

T64T-6AC-P1N

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (1998 - 8078c) © 2015 IMI International s.r.o.

74505-50

74505-53

74505-52

74505-55

8

18-026-981

5/15

Bracket mounting Nut

1

74504-50

30 3

4

74502-89

R64G - Olympian Plus plug-in system

Pressure regulator

Tamper resistant cap & seal wire

Yoke connector kit Porting block Adjustable pressure switch

Padlock with two keys

3

4355-51

9

74503-51 74507-50 4346-99 0613633 (brass)

R64G-KITR (for relieving version)

Gauges

Center back connection, white face

(full technical specification see datasheet

8.900.900)

6

Pressure range bar *1 MPa psi

0 ... 4

0 ... 10

0 ... 0,4 0 ... 58

0 ... 1 0 ... 145

50 mm

50 mm

0 ... 25 0 ... 2,5 0 ... 362 50 mm

*1) primary scale

R1/8

R1/8

12 1 14

18-013-013

Center back connection, black face for North America (full technical specification see datasheet

8.900.900)

6

Pressure range psig *1 bar MPa Ø Thread size Model

0 ... 60 0 ... 4 0 ... 0.4

2” (50 mm)

0 ... 160 0 ... 11 0 ... 1.1

2” (50 mm)

0 ... 400 0 ... 28 0 ... 2.8

2” (50 mm)

*1) primary scale

1/8 NPT

1/8 NPT

1/8 NPT

18-013-202

18-013-204

18-013-206

5/15

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (1998 - 8078c) © 2015 IMI International s.r.o.

en 8.240.200.03

R64G - Olympian Plus plug-in system

Pressure regulator

Basic dimensions

Standrad T-bar

5 or 3/16”

7

3

ø 47

157

105

1 15 1

Single yoke with bracket mounting

143

114

2,8

14,5

14,5

2,8

57 80

Dimensions in mm

Projection/First angle

66

# Minimum clearance required to remove unit from yoke

1 Main ports 1/4”, 3/8”, 1/2” or 3/4”

3

5

For main ports 3/4” only

Reduces by 4 mm with knob in locked position

7 Gauge port

Double yoke with bracket mounting

223

194 en 8.240.200.04

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (1998 - 8078c) © 2015 IMI International s.r.o.

5/15

Rear entry bracket

18-026-981

A A

20,5

41,5

8 +0,2 7,5

83,5

54,5

A-A

1

1 ‘O’-ring (included in scope of supply of bracket)

2

Adjustable pressure switch

4346-99

Voltage

Current

Pressure range

Repeatabillity

Average deadband

Electrical connection

(corresponding to choosen coil)

Degee of protection:

Adjustable

Material

24 V d.c./240 V a.c.

0,5 A (d.c.); 5 A (a.c.)

2 ... 10 bar

2% of full set point range at 20°C

0,8 ... 1,7 bar

EN 175301-803 - Form C, 15 mm

IP65

Standard

Body: Aluminium, Elastomers: NBR

3/2 Shut-off valve

Symbol

2

1 3

A

G1/4

G3/8

G1/2

G3/4

B

48

48

48

51

* B = Threaded inlet only, C = Threaded outlet only

ø C

27

27

27

33

Model

T64T-2G*-P1N

T64T-3G*-P1N

T64T-4G*-P1N

T64T-6G*-P1N

R64G - Olympian Plus plug-in system

Pressure regulator

Porting block

74507-50

Dimensions in mm

Projection/First angle

59

41

ø 22

G3/8

Pg 7

G1/4

7

73

OPEN

59 ø 22

41

6 Adjusting screw

B

6

Rc 1/8

17

7 Padlock hole 7,5 mm

27,5

13,5

Warning

These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under

»Technical features/data«.

Before using these products with fluids other than those specified, for non-industrial applications, life-support systems or other applications not within published specifications, consult IMI NORGREN.

Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes.

The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure.

System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided.

System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products.

5/15

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (1998 - 8078c) © 2015 IMI International s.r.o.

Diese Produkte sind ausschließlich in Druckluftsystemen zu verwenden.

Sie sind dort einzusetzen, wo die unter »Technische Merkmale/-

Daten« aufgeführten Werte nicht überschritten werden.

Berücksichtigen Sie bitte die entsprechende Katalogseite. Vor dem

Einsatz der Produkte bei nicht industriellen Anwendungen, in lebenserhaltenden- oder anderen Systemen, die nicht in den veröffentlichten

Anleitungsunterlagen enthalten sind, wenden Sie sich bitte direkt an

IMI NORGREN.

Durch Missbrauch, Verschleiß oder Störungen können in Pneumatiken 8.240.200.05

systemen verwendete Komponenten auf verschiedene Arten versagen.

Systemauslegern wird dringend empfohlen, die Störungsarten aller in Pneumatiksystemen verwendeten Komponententeile zu berücksichtigen und ausreichende Sicherheitsvorkehrungen zu treffen, um

Verletzungen von Personen sowie Beschädigungen der Geräte im

Falle einer solchen Störung zu verhindern.

Systemausleger sind verpflichtet, Sicherheitshinweise für den Endbenutzer im Betriebshandbuch zu vermerken, wenn der Störungsschutz nicht ausreichend gewährleistet ist.

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement