Photoelectrics Diffuse-reflective Type PD30CND10....SA

Photoelectrics Diffuse-reflective Type PD30CND10....SA
Photoelectrics
Diffuse-reflective
Type PD30CND10....SA
•
•
•
•
•
•
•
•
•
•
•
Product Description
The PD30CND10 sensor
family comes in a compact
10 x 30 x 20 mm reinforced
PMMA/ABShousing.
The sensors are useful in
applications where highaccuracydetectionaswellas
smallsizeisrequired.
Compact housing and high
Miniature sensor range
Range: 1 m
Sensitivity adjustment by Potentiometer
Modulated, red light 625 nm
Supply voltage: 10 to 30 VDC
Output: 100 mA, NPN or PNP preset
Make and break switching function
LED indication for output, stability and power ON
Protection: reverse polarity, short circuit and transients
Cable and plug versions
Excellent EMC performance
Ordering Key
power LED for excellent
performance-sizeratio.
The Potentiometer function
foradjustmentofthesensitivity makes the sensors highly
flexible. The output type is
preset(NPNorPNP),andthe
output switching function is
NOandNCoutput.
PD30CND10NAM5SA
Type
Housing style
Housing size
Housing material
Housing length
Detection principle
Sensing distance
Output type
Output configuration
Connection type
Sensitivity adjustment
Type Selection
Housing
WxHxD
Range
Sn
10x30x20mm 1000mm
10x30x20mm 1000mm
Connection
Ordering no.
NPN
Make and break switching
Ordering no.
PNP
Make and break switching
Cable
Plug
PD 30 CND 10 NASA
PD 30 CND 10 NAM5SA
PD 30 CND 10 PASA
PD 30 CND 10 PAM5SA
Specifications
Rated operating distance (Sn) Upto1m,
referencetargetKodaktest
cardR27,white,90%
reflective,200x200mm
Blind zone
≤20mm@maximum distance
Sensitivity
Electricaladjustment 210˚
Mechanicaladjustment 240˚ Temperature drift
≤0.2%/ºC
Hysteresis (H) 5%to20%
Rated operational volt. (UB) 10to30VDC
(rippleincluded)
Ripple (Urpp) ≤10%
Output current
Continuous(Ie) ≤100mA
Short-time(I)≤100mA
(max.loadcapacity100nF)
No load supply current (Io) ≤25mA@UB max
Minimum operational current (Im) ≤0.5mA
Specificationsaresubjecttochangewithoutnotice(17.09.2012)
OFF-state current (Ir) ≤100µA
Voltage drop (Ud)≤2VDC@Ie max
Protection Short-circuit,reversepolarity
andtransients
Light source InGaAlP,LED,625nm
Light typeRed,modulated
Emitter angle
±2º@halfsensing distance
Light spot
1.5timesthesensingdistance 110mm Ambient light ≤10,000lux
Operating frequency (f)≤1000Hz
Response time
OFF-ON(tON)≤0.5ms
ON-OFF(tOFF) ≤0.5ms
Power ON delay (tv) ≤30ms
Output function
Opencollector NPNorPNPbysensortype
Output switching function N.O.andN.C.
1
PD30CND10....SA
Specifications (cont.)
Indication
OutputON LED,yellow
SignalstabilityONand
PowerONLED,green.Seecurvefor
conditionofstability
Environment
Installationcategory III(IEC60664/60664A;
60947-1)
Pollutiondegree 3(IEC60664/60664A;
60947-1)
DegreeofprotectionIP67(IEC60529;60947-1)
Ambient temperature
Operating -25° to+60°C(-13° to+140°F)
Storage -40° to+70°C(-40° to+158°F)
Vibration 10to150Hz,1.0mm/15G
(IEC60068-2-6)
Shock 30g/11ms,3pos,3neg
peraxis
(IEC60068-2-6,60068-2-32)
Rated insulation voltage ≤500VAC(rms)
Housing material
Body ABSLightGrey
FrontglasPMMARed
Trimmershaft POMDarkGrey
Connection
Cable PVC,black,2m
4x0.14mm2,Ø=3.3mm
Plug M8,4-pin(CON.54-series)
Weight Cableversion ≤50g
Plugversion ≤20g
CE-marking Yes
ApprovalscULus(UL508+CSA)
Operation Diagram
Tv=PowerONdelay
Power supply
ON
OFF
Break Output (N.C.)
Present
Not Present
Tv
ON
OFF
Make Output (N.O.)
ON
OFF
Object
Tv
Signal Stability Indication
Wiring Diagrams
NPN
2WH
4BK
Excess Gain
1.10
Operation level x 1.10
1.0
0.90
Operation level
Operation level x 0.90
Time
Green LED ON
Yellow LED ON
1BN
3BU
PNP
1BN
4BK
2WH
3BU
2
Specificationsaresubjecttochangewithoutnotice(17.09.2012)
PD30CND10....SA
Detection Diagram
Excess Gain
Sensor
Y
R27
Kodac test card
7,9
200
Distance (Inches)
Distance (Inches)
15,7
400
23,6
31,5
600
800
39,4
0,0
1.000
47,2
55,1
2,0
1,6
1,2
0,8
0,4
0,0
-0,4
-0,8
-1,2
-1,6
-2,0
1.000 1.200 1.400
Excess Gain
0,0
50
40
30
20
10
0
-10
-20
-30
-40
-50
0
(Inches)
(mm)
X
0,4
3,9
39,4
393,7
1.000,00
100
100,00
10
10,00
1,00
10.000
1
1
10
100
1.000
Distance (mm)
Distance (mm)
Dimensions
Plug version
10.6
20
20
10.6
Cable version
Output LED
Yellow
Power / Stability LED
Green
10.6
10.8
17
1.1
Two, 9.5 dia.
Lenses
Receiver
15
22
30
25.4
15
Two M3
Potentiometer
Two, 9.5 dia.
Lenses
5.5 5.5
Optical axis
5.5 5.5
22
30
Optical axis
Potentiometer
7
1.1
Receiver
25.4
10.6
10.8
17
Power / Stability LED
Green
7
Output LED
Yellow
Emitter
Emitter
Two M3
10.25
Installation Hints
To avoid interference from inductive voltage / Relief of the cable strain
current peaks, separate the proximity switch
cables from any other power cables. E.g.
Engine, contactor or solenoid cables
Protection of the sensing face
Sensor mounted on a mobile carrier
Incorrect
Incorrect
Incorrect
Correct
Correct
> 100 mm
The cable should not be pulled
A proximity switch should not serve
as mechanical stop
Any repetitive flexing of the
cable should be avoided
Accessories
Delivery Contents
• MountingbracketAPD30-MB1orAPD30-MB2tobe
purchasedseparately.
• Photoelectricswitch:PD30CND10...
• Screwdriver
• Packaging: Plasticbag
Specificationsaresubjecttochangewithoutnotice(17.09.2012)
3
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF