VSP737 LED Processor Quick Start
VIEWSIZE THE WORLD
–
For full installation, configuration, and operation details, refer to the
VSP737 user manual, which is available at www.rgblink.com.
This guide provides quick start instructions for an experienced installer to set
up and operate the VSP 737.
NOTE
Installation and Connection
Rear Panel
the on
NT for llati
A
T
m sta
OR k.co d in g the
P
n
i
IM gbl al an ctin
u
.r
.
ne
ww man con urce
w
e
r
o
s
r
to
se
o
r
fer e u bef we
Re plet ions e po
com truct to th
ins duct
o
pr
Interface
1 ~ 4
9 ~ 12
CVBS Input BNC
18 DVI+VGA Output DVI-I
5
6
Mini Switch
19 DVI Output DVI-I
25 Power port IEC-3
7
USB Control Port
RS232 Control Port
8
RJ-45 Port
26 Switch and Power
13 15 21 23 DVI Input DVI-I
14 16 22 24 VGA Input DB-15
17 20
USB Input
Step 1-Install
Power down all inputs and outputs.
Step 2-CVBS input port BNC
CVBS is for composite signal input
connection, support composite signal
include: PAL, NTSC and SECAM, and
CV5~CV8 is background signal source.
Step 3-VGA Input DB15
VGA input is for VGA player
connection, Composite with YPBPR, can
receive signal from DVD player, and
VGA3/4 is background signal source.
Step 4-DVI1/2 Input DVI-I
DVI1/2 input can receive HDMI from
HD player and computer video signal
via DVI connector.
Step 5-DVI3/4 Input Port
DVI3/4 input can receive computer
signal via DVI image. User can
receive DVI signal via DVI cable as
background image.
Step 6-Preview(DVI1+VGA) Output Port
Can connect display with DVI
port, and used to preview signal
state, or preview with VGA
monitor via tieline adapter.
One end of DVI to DVI+VGA
tieline is DVI-I or DVI-D
male port, and another end is
DVI-I or DVI-D female port
with a VGA male port.
One end of DVI to VGA tieline
is DVI-I male port, and another
end is VGA male port.
Step 7-Program(DVI2) Output Port
DVI output is for DVI display
connection or LED control system,
etc.
Add: S603-604 Weiye Building Torch Hi-Tech Industrial Development Zone Xiamen, Fujian Province, P.R.C
Tel: 00865925771197
Fax: 00865925771202
Email: [email protected]
http://www.rgblink.cn
VSP 737 Quick Start
Version 1.0
Page 1 of 3
Step 8
Lan Control Port
Local Control-Front Panel Operation
Apply the CAT5 crosswire, with T568A standard for
one end and T568B for the other, according to the
informational diagram below. User can apply the
RS232 or USB port to alter the default IP address
Step 1-Set Output Resolution
192.168.0.100 of device.
Tap output button to open the resolution setup menu,
End Terminal Definition of cross wire terminal CAT5
Termi
Color of T568A
Color of T568B
crosswire rotate the knob, select the required resolution and tap the
nal
knob of NEXT button to confirm, system will log out in
1
Geen-White
Orange-White
with
2
Green
Orange
seconds automatically.
T568A
3
Orange-White
Green-White
standard
NOTE 10 output resolutions as below are feasible for
4
Blue
Blue
VSP 737: 800x600x60Hz, 1024×768×60Hz ,
5
Bule-White
Blue-White
for one end
Orange-White
Green
Plug the cross 6
and T568B 1280×768×60Hz, 1280×1024×60Hz, 1366×768×60Hz,
Brown-White
Brown-White
cable into RJ- 7
1440x900x60_nrHz, 1440x900x60Hz, 1600x1200x60Hz,
for the
45 port
8
Brown
Brown
1600x1200x60_rHz,1920x1080x60Hz;
other
T568A
T568B
Step 9-USB Port
Step 2-Input signal programming
USB cable is for the connection between
VSP 737 and computer.
VSP 737 has 8 composite video inputs, 4 VGA inputs
(compatible of YPBPR), 4 DVI inputs(compatible of
Step 10-Serial Port
HDMI 1.3), 4 USB inputs, among these inputs, 4
For RS232-to-RJ11 cable, the RS232 end is to connect
composite inputs, 2 VGA inputs, 2 DVI inputs and 2
computer or other operating system, the RJ11 end is to
USB inputs are background input, corresponding to the
connect the RJ11 port on the rear panel of VSP 737.
inputting signals from ports.
Details as below:
VSP 737 supports 4 channel input programming: Use
Termi
Function
RS-232
Function
RS-422
nal
the PRO button and signal source composite button to
Sending(-)
2
TX
Sending
TXReceiving(-)
program on the inputting signal source, and
3
RX
Receiving
RXGround Signal
Ground Signalling
5
GND
GND
preliminarily monitor on the PREVIEW output port on
Receiving(+)
7
--Without Use
RX+
back panel, all programming is finished in the
Plug the
Sending(+)
8
--Without Use
TX+
cross cable
PREVIEW channel.
into
Programming steps as below: Tap PRO button, button
RS232/RS422 Termi RJ-11
Function
nal
light on, yellow background silkscreen effective,
port
1
--Without Use
present inputting signal sources of 4 channels are
2
RX
Receiving
3
TX
Sending
lighted on. The default input of LAYER A is: DVI1,
4
GND
Ground Signal
Plug cross cable
while LAYER B: DVI2, and BGA: DVI3, and BGB:
into RJ11 port
DVI4. Directly select the intended button to change for
Step 11
Power Port
other input signals, e.g. tag PRG button then CV2
VSP 737 use dual power backups to connect IEC port button to change DVI1 signal to CV2 signal, the LCD
to the power input port of VSP 737, 85-265 volt AC is screen will show CV2 LAYER A. The same goes for
available for VSP 737's power supply, and the present changing signals of other channels. After the setting,
worldwide power system is compatible for VSP 737. tap PRG button, log out the programming function,
button light off, inputting signal programming
finished.
NOTE The corresponding input signal sources of
these 4 channels are as below:
LAYER A:CV1,CV2,VGA1,DVI1, USB1;
LAYER B:CV3,CV4,VGA2,DVI2, USB2;
Power On
Turn on the mains switch, information about RGBlink BG A:CV5,CV6,VGA3,DVI3, USB3;
BG B:CV7,CV8,VGA4,DVI4, USB4;
company and the device will be displayed on LCD
screen in turn. After self-test, device goes into the ready
mode, LCD screen will in turn show input signal and
format/ output format/ software version and device
serial number. User can control or adjust the device via
buttons on front panel, TCP/IP, RS 232 or USB remote
operation.
ADD: S603 Weiye Building Torch Hi-Tech Industrial Development Zone, Xiamen, Fujian Province, P.R.C.
Fax:00865925771202
Email: [email protected]
http://www.rgblink.cn
VSP 737 Quick Start
Version 1.0
Page 2 of 3
Step 3-Input signal switching
Step 6-SAVE choose
There have three ways to switch :WIPE, CUT and MIX: VSP 737 support 10 user adjust saving modes. Push
WIPE :In WIPE menu there are many modes to choose. LOAD button and LOAD 1- LOAD10, buttons will
CUT: is the direct switch without transiting effect ; light on, push any one of them to save the setting. After
that user can push each of them to call the setting.push
MIX :fade in fade out, click this button can set the
the LOAD button again , the LOAD1-10 will light off ,
times of fade in fade out 。
and ESC .
NOTE User can program the signal or other setting
Step 7-Factory Reset
in the preview channel, after that ,click the WIPE,
Factory Reset: When there is wrong operation during
CUT or MIX button, can finish the singal swtch.
parameter adjustment, users can recall the device and
WIPE :WIPE switch have some transition effect ; readjust the parameter. Following the steps: Press
Control option in the menu bar, and click the submenu
Reset to initiate factory reset. LED will display in the
RESET FINISHED.
Step 4-SCALE
In the LAYER A or LAYER B,click the scale into the
Scale menu, rotate the knob,choose the Scale setting:
Scale Width;Scale Heigth;
Scale Pos X: posotion X; Scale Pos Y: position Y;
after adjust the scale , click the NEXT button ,and then
adjust the knob , after setting ,click the NEXT button
again ,and finish this setting
NOTE The fast operation of knob ,the fast if the
value of Scale。Rate of change will be from 1 to 10
and to 100.
Step 5-SAVE
VSP 737 support 10 user saving modes. Push SAVE
button and SVAE1-10,buttons will light on, push any
one of them to save the setting. After that user can
push each of them to call the setting.
NOTE SAVE1 setting is default user setting after
VSP 737 power on. the user settings will gone after
factory reset.
ADD: S603 Weiye Building Torch Hi-Tech Industrial Development Zone, Xiamen, Fujian Province, P.R.C.
Fax:00865925771202
Email: [email protected]
http://www.rgblink.cn
VSP 737 Quick Start
Version 1.0
Page 3 of 3
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement