Specification Optimizer P700
POWER OPTIMIZER
SolarEdge Power Optimizer
Module Add-On for Commercial Installations
P600 / P700
PV power optimization at the module-level
The most cost effective solution for commercial and large field installations
Up to 25% more energy
Superior efficiency (99.5%)
Balance of System costs reduction; 50% less cables, fuses and combiner boxes
Fast installation with a single bolt
Next generation maintenance with module level monitoring
Module-level voltage shutdown for installer and firefighter safety
Use with two PV modules connected in series
USA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - AUSTRALIA - THE NETHERLANDS - ISRAEL
www.solaredge.com
SolarEdge Power Optimizer Module Add-On
for Commercial Installations P600 / P700
P600
(for 2 x 60-cell PV modules)
P700
(for 2 x 72-cell PV modules)
600
700
W
96
125
Vdc
12.5 - 105
Vdc
Adc
%
%
INPUT
Rated Input DC Power(1)
Absolute Maximum Input Voltage
(Voc at lowest temperature)
MPPT Operating Range
Maximum Continuous Input Current (Isc)
Maximum Efficiency
Weighted Efficiency
Overvoltage Category
12.5 - 80
10
99.5
98.6
II
OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER)
Maximum Output Current
Maximum Output Voltage
15
85
Adc
Vdc
OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF)
Safety Output Voltage per Power Optimizer
1
Vdc
STANDARD COMPLIANCE
EMC
Safety
RoHS
Fire Safety
FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3
IEC62109-1 (class II safety)
Yes
VDE-AR-E 2100-712:2013-05
INSTALLATION SPECIFICATIONS
Compatible SolarEdge Inverters
Maximum Allowed System Voltage
Dimensions (W x L x H)
Weight (including cables)
Input Connector
Output Connector
Output Wire Length
Operating Temperature Range(3)
Protection Rating
Relative Humidity
(1)
(2)
(3)
Three phase inverters
SE15K & larger
Three phase inverters
SE16K & larger
1000
128 x 152 x 43 / 5 x 5.97 x 1.69
128 x 152 x 48 / 5 x 5.97 x 1.89
930 / 2.05
MC4(2)
MC4
1.2 / 3.9 (portrait orientation) or
1.2 / 3.9 (portrait orientation) or
1.8 / 5.9 (landscape orientation)
2.1 / 6.9 (landscape orientation)
-40 - +85 / -40 - +185
IP68 / NEMA6P
0 - 100
Vdc
mm / in
gr / lb
m / ft
˚C / ˚F
%
Rated combined STC power of 2 modules connected in series. Module of up to +5% power tolerance allowed.
For other connector types please contact SolarEdge.
For ambient temperature above +70˚C / +158˚F power de-rating is applied. Refer to “Power Optimizers Temperature De-Rating Application Note” for more details.
PV SYSTEM DESIGN USING A
SOLAREDGE INVERTER(4)(5)
Compatible Power Optimizers
Minimum String Length
Maximum String Length
THREE PHASE SE15K
AND LARGER
THREE PHASE SE16K
AND LARGER
P600
P600 & P700
Power Optimizers
PV Modules
Power Optimizers
PV Modules
Maximum Power per String
Parallel Strings of Different Lengths or Orientations
THREE PHASE
SE33.3K
13
26
30
60
11250(6)
12750(7)
Yes
(4)
(5)
(6)
P600 and P700 can be mixed in one string. It is not allowed to mix P600/P700 with P300/P350/P405/P500 in one string
In a case of odd number of PV Modules in one string it is allowed to install one P600/P700 power optimizer connected to one PV Module.
For SE27.6K: It is allowed to install up to 13,500W per string when 3 strings are connected to the inverter and when the maximum power difference between the strings is up to 2,000W;
inverter max DC power: 37,250W.
(7)
For SE33.3K: It is allowed to install up to 15,000W per string when 3 strings are connected to the inverter and when the maximum power difference between the strings is up to 2,000W;
inverter max DC power: 45,000W.
© SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE
are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein
are trademarks of their respective owners. Date: 06/2015. V.02. Subject to change without notice.
W
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising