Open the cover of the detector (press it from both sides up to
the lines on the housing. see the picture)
Test button with LED
Attach the rear panel with the two provided screws to the de
sired location. Tighten the screws firmly, being sure that the
panel is not crooked.
Study the installation manual of the receiver unit (control panel) to learn how to enter the enrolling mode to enroll the de
tector.
The MD-2100R detects smoke and wirelessly transmits a
signal to a receiver (control panel). It also has a built in buzz
er to warn people in the immediate vicinity. For testing purpo
ses the detector is equipped with a testing button. The detector makes regular auto testing and reports its condition to the
system regularly for full supervision. The LED indicator can
be turn on/off upon your requirement.
Specifications
power 6 V DC
current: static 20Ua-40Ua,alarm 20mA
battery life time about 2 year
working environment indoor use , -5 to +50 humidity 10%-90%
battery low voltage indication: sound once in each 2 hours
self test indication: red LED turn on then buzzer sound 2 times
alarm output indication: red LED turn on 5 seconds then buzzer
sound
working frequency 433,92 MHz
working range max. 100 m (open area)
radiation of sensor max. 4 kBq
built in siren 95dB/1m
LED jumper: short circuit ON,open circuit OFF
Installation
The detector should be installed on the proper place, with the
distance from walls 0.6 m as a minimum. The detector should
not be installed in a place with poor air circulation. If you install
the MD-2100R in a large space, install at least two detectors.
A detector can cover an area of about 50 m3 of free space (no
partitions). The detector should not be installed close to any
fan, heating/cooling vent, fluorescent lamp or air ionizer. The
MD-2100R is not suitable for places with a high concentration
of paint solvents or car exhausts (fumes). While deciding where
to install the detector, keep in consideration that detector's batteries have to be replaced from time to time (approximately
once 2 year).
Note: the detector can also be triggered by heavy cigarette
smoke or fumes from cooking.
Connect batteries in the detector (removing the plastic tape).
The MD-2100R will transmit an enrollment signal and its buzzer will make a sound. From this moment the detector is ready to work. Now the LED will flash once in each minute.
Attach the detector's front cover to the rear panel so that both
tabs click. Check that the detector is fixed firmly.
Press and hold the testing button, the red LED will turn on and
the buzzer will sound twice. Also we can use the smoke to test it. When smoke is detected, the detector will start an alarm
(buzzer&repay). After the smoke concentration drops, the
detector will go to stand by mode again.
Enroll to receiver(control panel) and test
To enroll the detector to the receiver(control panel). Press and
hold the test button according to the prompt message or indication from the control panel. Conduct the test process, the detector will make an alarm sound and send a signal to the receiver(control panel) to trigger it.
Battery testing and replacement
The detector checks the condition of its batteries automatically.
If it is necessary to replace batteries, the detector give a low
voltage indication buzzer sound once in each 2 hours. After in
stallation of new batteries the detector's buzzer will make a sound to confirm that it is ready again.
Note: We recommend removing dust from the detector every 6
months. Use a dry cloth or blow on it gently. Do not open
the optical chamber.