Fieldbus temperature transmitters Model T53.10, for FOUNDATION™ Fieldbus and PROFIBUS PA ®

Fieldbus temperature transmitters Model T53.10, for FOUNDATION™ Fieldbus and PROFIBUS PA ®
Electrical
temperature measurement
Fieldbus temperature transmitters
Model T53.10, for FOUNDATION™ Fieldbus and PROFIBUS® PA
WIKA data sheet TE 53.01
Applications
■■ Process industry
■■ Machine building and plant construction
Special features
■■ FOUNDATION™ Fieldbus ITK Version 4.61
■■ PROFIBUS® PA Profile 3
■■ Automatic switch between protocols
■■ Explosion protection, Ex i, instrinsically safe / FISCO
■■ Explosion protection, Ex n
Fieldbus Temperature Transmitter, Model T53.10.0IS
Description
The Fieldbus temperature transmitter model T53.10 with
FOUNDATION™ and PROFIBUS® PA Fieldbus Communication is suitable for temperature measurement with resistance
thermometers and thermocouples. Furthermore resistance
and mV measurements with or without customer specific
linearisation are possible. Difference, average or redundancy
temperature measurements can be realised.
The T53 is available at FOUNDATION™ Fieldbus
with LAS-Functionality (Link Active Scheduler) and
PID-Regulation. These functionalities allows for masterindependent regulations in the field housing.
The Fieldbus temperature transmitter model T53.10 has
a polarity-independent bus connection. Due to its small
dimensions the temperature transmitter is suitable for all
DIN Form B connection heads.
Delivered with a basic configuration (according to the ■
ordering options) or customer specific configuration in line
with the configuration options.
WIKA data sheet TE 53.01 ∙ 06/2010
Page 1 of 4
Specifications
Input
configurable
Resistance thermometers
Thermocouples
External CJC (cold junction compensation)
Resistance sensor
Potentiometric resistance sensor
mV-sensor
Basic configuration
Sensor current
Max. cable resistance
Measuring accuracy, at 24 °C ± 4 K
Error cold junction compensation (CJC)
Output
Version
Functionality
Function blocks
Execution time, PID-controller
Electromagnetic compatibility (EMC)
Ambient conditions
Ambient and storage temperature
Maximum permissible humidity
Vibration
Special features
Insulation voltage, test / operation
Response time (programmable)
Updating time
Execution time, analogue input block
Case
Material
Ingress protection
case
terminal
Cross section of terminal connectors
Weight
Page 2 of 4
Model T53.10
Sensor
Measuring range
Standard
Pt25 ... Pt1000 (α = 0.00385)
-200 ... +850 °C
IEC 60751
Pt25 ... Pt1000 (α = 0.003916)
-200 ... +850 °C
JIS C1604 (1989)
Ni25 ... Cu1000
-60 ... +250 °C
DIN 43760
Cu10 ... Cu1000
-50 ... +200 °C
α = 0.00427
B
+400 ... +1820 °C
IEC 584
E
-100 ... +1000 °C
IEC 584
J
-100 ... +1200 °C
IEC 584
K
-180 ... +1372 °C
IEC 584
L
-200 ... +900 °C
DIN 43710
N
-180 ... +1300 °C
IEC 584
R
-50 ... +1760 °C
IEC 584
S
-50 ... +1760 °C
IEC 584
T
-200 ... +400 °C
IEC 584
U
-200 ... +600 °C
DIN 43710
W3
0 ... +2300 °C
ASTM E988-90
W5
0 ... +2300 °C
ASTM E988-90
-40 ... +135 °C
0 ... 10 kΩ
0 ... 100 kΩ
-800 ... +800 mV
Pt100, 3-wire 0 ... 100 °C
typically 0.2 mA
50 Ω per wire
Sensor
Base accuracy
Temperature coefficient
Pt100 and Pt1000
≤ ±0.1 °C
≤ ±0.002 °C / °C
Ni100
≤ ±0.15 °C
≤ ±0.002 °C / °C
Cu10
≤ ±1.3 °C
≤ ±0.02 °C / °C
Lin. R.
≤ ±0.05 Ω
≤ ±0.002 Ω / °C
Volt
≤ ±10 µV
≤ ±0.2 µV / °C
TE type: E, J, K, L, N, T, U
≤ ±0.5 °C
≤ ±0.01 °C / °C
TE type: B, R, S, W3, W5
≤ ±1 °C
≤ ±0.025 °C / °C
≤ ±0.5 °C
FOUNDATION™ Fieldbus
PROFIBUS® PA
ITK version 4.61
EN 50170 vol. 2 / profile 3
Basic or LAS
2 analogue and 1 PID
2 analogue
< 200 ms
EMC directive 2004/108/EC, EN 61326 Emission (Group 1, Class B) and immunity (industrial
application) and NAMUR NE 21
-40 ... +85 °C
95 % relative humidity, without condensation
2 ... 100 Hz 4 g DIN EN 60068-2-6
AC 1.5 kV / AC 50 V
1 ... 60 s
< 400 ms
< 50 ms
for head mounting design, incl. spring-loaded mounting screws
Plastic, PBT, glass fibre reinforced
IP 68 per IEC 529 / EN 60529
IP 00 per IEC 529 / EN 60529
0.14 ... 1.5 mm²
approx. 0.05 kg
WIKA data sheet TE 53.01 ∙ 06/2010
Explosion protection / power supply
Model
Approvals
T53.10.0IS EC-type examination certificate:
KEMA 06ATEX0148X
Zone 0,1: II 1G Ex ia IIC T4/T5/T6
Zone 0,1: II 1D Ex iaD
CSA Approval 1807316
IS, Class I, Division 1, Group A, B, C, D
Permissible ambient/
storage temperature
(per temperature codes
and classes)
Safety-related maximum vales for■
Current loop
Sensor
-40 … +75 °C (T4)
-40 … +65 °C (T5)
-40 … +45 °C (T6)
Ui = DC 30 V
Ii = 300 mA
Pi = 1.3 W
-40 … +85 °C (T4)
-40 … +75 °C (T5)
-40 … +60 °C (T6)
-40 … +85 °C (T4)
-40 … +60 °C (T5)
FM Approval: 3027564 (Inst. Drg: 11175631) -40 … +45 °C (T6)
IS, Class I, Division 1, Group A, B, C, D
Non-Incendive, Class I, Division 2,
-40 … +85 °C (T4)
Group A, B, C, D
-40 … +60 °C (T5)
-40 … +45 °C (T6)
T53.10.0IS EC-type examination certificate:
KEMA 06ATEX0148X
Zone 0,1: II 2G (1) G Ex ib [ia] IIC T4/T5/T6
-40 … +85 °C (T4)
-40 … +75 °C (T5)
-40 … +60 °C (T6)
CSA Approval 1807316
IS, Class I, Division 1, Group A, B, C, D
-40 … +85 °C (T4)
-40 … +75 °C (T5)
FM Approval: 3027564 (Inst. Drg: 11175631)
-40 … +60 °C (T6)
IS, Class I, Division 1, Group A, B, C, D
Non-Incendive, Class I, Division 2,
Group A, B, C, D
-40 … +85 °C (T4)
T53.10.0NI EC-type examination certificate:
-40 … +75 °C (T5)
KEMA 06ATEX0148X
-40 … +60 °C (T6)
Zone 2: II 3GD Ex nA [nL] IIC T4/T5/T6
Zone 2: II 3GD Ex nL IIC T4/T5/T6
Zone 2: II 3GD Ex nA [ic] IIC T4/T5/T6
Zone 2: II 3GD Ex ic IIC T4/T5/T6
(connections 1 and 2)
Ci = 2 nF
Ui = DC 30 V
Li = 1 µH
Ii = 120 mA
Pi = 0.84 W
Ci = 2 nF
Li = 1 µH
Ui = DC 17.5 V
(FISCO)
Ii = 250 mA
Pi = 2.0 W
Ui = DC 15 V
Ii = beliebig
Pi = beliebig
Ci = 2 nF
Li = 1 µH
Ui = DC 30 V
Ii = 250 mA
Pi = 5.32 W
Ci = 2 nF
Li = 1 µH
Ui = DC 17.5 V
(FISCO)
Ii = beliebig
Pi = beliebig
Ci = 2 nF
Li = 1 µH
Ui = DC 32 V
FNICO (FISCO)
Ci = 2 nF
Li = 1 µH
Ui = DC 17.5 V
(connections 3
up to 6)
Uo = 5.7 V
Io = 8.4 mA
Po = 12 mW
Co = 40 µF
Lo = 200 mH
Power supply
UB 1)´/ current
consumption
DC 9 … 32 V/
< 11 mA
Ci = 2 nF
Li = 1 µH
CSA Approval 1807316
FM Approval: 3027564 (Inst. Drg: 11175631)
Non-Incendive, Class I, Division 2,
Group A, B, C, D
1) Depending on the safety-relevant upper limit values for the circle of current loop. (for this see also the type examination certificate).
1 Sensor
Potentiometric sensor
2099318.02
Designation of terminal connectors
2 Sensors
Clamp 1 and 2: Connection FOUNDATION™ Fieldbus or PROFIBUS® PA (protected against reverse polarity)
WIKA data sheet TE 53.01 ∙ 06/2010
Page 3 of 4
Dimensions in mm
2099288.02
Screw M4
approx. 30 mm
spring-loaded
Accessory
Field
Communicator
FC375
Field housing
HART®
Field Communicator FC375 English for
and FOUNDATION™ Fieldbus,
ATEX II 2G (1GD) EEx ia IIC T4, FM Class I, Division 1, Groups A, B, C, D ■
T4, CSA Ex ia IIC
NiMH battery, with power supply AC 90 ... 240 V, with EASY UPGRADE OPTION
Field housing, plastic (ABS), IP 65, for mounting of a head mounting transmitter, ■
permissible ambient temperature: -40 ... +80 °C,
82 x 80 x 55 mm (W x L x H), with two cable glands M16 x 1.5
Adapter, plastic/stainless steel, for mounting on a DIN rail
Adapter, steel tin galvanized, for mounting on a DIN rail
Order No.
2133702
3301732
3593789
3619851
The specifications given in this document represent the state of engineering at the time of publishing.
We reserve the right to make modifications to the specifications and materials.
Page 4 of 4
WIKA data sheet TE 53.01 ∙ 06/2010
WIKA Alexander Wiegand SE & Co. KG
Alexander-Wiegand-Straße 30
63911 Klingenberg/Germany
Tel.
(+49) 9372/132-0
Fax
(+49) 9372/132-406
E-mail info@wika.de
www.wika.de
06/2010 GB
Accessory (please order seperately)
Was this manual useful for you? yes no