Datasheet Art.No. 56.703.0055.0 Feed-through terminal WKFN 2,5 /35 grey

Datasheet Art.No. 56.703.0055.0 Feed-through terminal WKFN 2,5 /35 grey
Datasheet
Art.No. 56.703.0055.0
Feed-through terminal WKFN 2,5 /35 grey
Feed-through DIN rail terminal block with spring clamp connection for mounting
on TS 35, nominal cross section 2.5 mm², width 5 mm, color gray
Art.No.
EAN
Order unit
56.703.0055.0
4015573718326
100 pieces
Approvals
Technical data
General
Nominal cross section
Colour
Number of levels
Number of clamp positions per level
Width/grid dimension
Insulating housing
Inflammability class of insulation material acc. with UL94
Explosion-tested version "Ex e"
Mounting method
Terminal blocks for electrical installations
2.5 mm²
Grey
1
2
5 mm
PA666
V0
Yes
DIN rail (top hat rail) 35/7.5 mm
Yes
Technical data
Rated current
Rated voltage
Rated impulse voltage
Pollution degree
Closing plate required
Length
Type of insulation material
24 A
800 V
8 kV
3
Yes
5 mm
Thermoplastic
Connection Data
Connection type 1
Connection type 2
Tension clamp connection
Tension clamp connection
Page: 1 of 3
fasis
Feed-through blocks with tension spring connection
WKFN 2,5/35
• Feed-through block with tension spring
connection for mounting on TS 35
• Nominal cross section 2.5 mm2
• E x e I/II ? II 2GD IM2
Follow the EX installation instructions on page 143
Description
Type
Part No.
Feed-through block, gray
Feed-through block, blue
WKFN 2,5/35
WKFN 2,5/35 BLAU
56.703.0055.0
56.703.0055.6
General data
Width / length / height, incl. TS 7.5
Wire strip length
Approvals
Technical data
Cross section fine-stranded
Cross section solid/stranded
Cross section, AWG
Rated current
Rated voltage
Rated impulse voltage
Pollution degree
Note
Accessories
End plate, gray
End plate, blue
Partition, gray
WKFN 2,5 D1/2/35
• Duo feed-through block with tension spring
connection for mounting on TS 35
• Nominal cross section 2.5 mm2
• E x e I/II ? II 2GD IM2
Follow the EX installation instructions on page 143
• Nominal cross section 2.5 mm2
• E x e I/II ? II 2GD IM2
Follow the EX installation instructions on page 143
22 A1)
550 V
1)
Type
Part No.
APFN 2,5
APFN 2,5 BLAU
TWFN 2,5
07.312.6755.0
07.312.6755.6
07.312.6855.0
Type
Part No.
56.703.5055.0
56.703.5055.6
General data
Width / length / height, incl. TS 7.5
Wire strip length
Approvals
Technical data
5 mm / 60 mm / 38 mm
11 mm
+LNJTMnD9 IEC
UL
EN 60 947-1-1
2
0.13 – 2.5 mm
0.13 – 4 mm2
22 – 12
24 A
20 A
800 V
600 V
8 kV
3
CSA
24 – 12
24 A
600 V
22 A1)
550 V
Type
Part No.
APFN 2,5 D1/2
APFN 2,5 D1/2 BLAU
TWFN 2,5 D1/2
07.312.6955.0
07.312.6955.6
07.312.7055.0
Type
Part No.
WKFN 2,5 D2/2/35
WKFN 2,5 D2/2/35 BLAU
56.703.5155.0
56.703.5155.6
Accessories
End plate, gray
End plate, blue
Partition, gray
24 – 12
24 A
600 V
for 40 K and
45 K
Std. Pack
Feed-through block, gray
Feed-through block, blue
CSA
100
100
PTB 04 ATEX 1051 U
?
EN 60 079-0/-7
0.2 – 2.5 mm2
0.13 – 4 mm2
1)
5 mm / 72 mm / 38 mm
11 mm
+LNJTMnD9 IEC
UL
EN 60 947-1-1
0.13 – 2.5 mm2
0.13 – 4 mm2
22 – 12
24 A
20 A
800 V
600 V
8 kV
3
10
10
10
Std. Pack
Description
General data
Width / length / height, incl. TS 7.5
Wire strip length
Approvals
Technical data
for 40 K and
45 K
Std. Pack
WKFN 2,5 D1/2/35
WKFN 2,5 D1/2/35 BLAU
Cross section fine-stranded
Cross section solid/stranded
Cross section, AWG
Rated current
Rated voltage
Rated impulse voltage
Pollution degree
Note
64
24 – 12
24 A
600 V
100
100
PTB 04 ATEX 1051 U
?
EN 60 079-0/-7
0.2 – 2.5 mm2
0.13 – 4 mm2
Feed-through block, gray
Feed-through block, blue
Accessories
End plate, gray
End plate, blue
Partition, gray
• Duo feed-through block with tension spring
connection for mounting on TS 35
CSA
Description
Cross section fine-stranded
Cross section solid/stranded
Cross section, AWG
Rated current
Rated voltage
Rated impulse voltage
Pollution degree
Note
WKFN 2,5 D2/2/35
5 mm / 47 mm / 38 mm
11 mm
+LNJTMnD9 IEC
UL
EN 60 947-1-1
2
0.13 – 2.5 mm
0.13 – 4 mm2
22 – 12
24 A
20 A
800 V
600 V
8 kV
3
Std. Pack
10
10
10
Std. Pack
100
100
PTB 04 ATEX 1051 U
?
EN 60 079-0/-7
0.2 – 2.5 mm2
0.13 – 4 mm2
22 A1)
550 V
1)
Type
Part No.
APFN 2,5 D2/2
APFN 2,5 D2/2 BLAU
TWFN 2,5 D2/2
07.312.7155.0
07.312.7155.6
07.312.7255.0
for 40 K and
45 K
Std. Pack
10
10
10
Minimum cross section solid
Maximum cross section solid
Minimum cross section fine stranded
Maximum cross section fine stranded
Wire strip length
0.13 mm²
4 mm²
0.13 mm²
2.5 mm²
11 mm
Technical Data UL/CSA
Cross section UL
Voltage UL
Current factory wiring
Current field wiring
Cross section CSA
Voltage CSA
Current CSA
22-12 AWG
600 V
20 A
20 A
24-12 AWG
600 V
24 A
Page: 2 of 3
Drawings
Page: 3 of 3
facts & data
Information about EX e
Technical information
• The information regarding cross sectional area and connection types pertains to unprepared wires without ferrules!
Ferrules are not necessary for secure connection. Whenever ferrules are used, make sure that the tools specified by the
manufacturer are used exclusively.
• The voltage ratings apply to the terminals in their intended application. When different products are mounted adjacent to
each other, the proper isolation distances must be adhered to.
• If the ground blocks are not used in block assemblies, but are mounted to the rail as single terminal blocks, end clamps
have to be used.
• A detailed description of technical data, the standards requirements, and the application conditions are available in the
flyer facts & DATA .
ATEX regulation

• For the use of DIN rail terminal blocks in Ex areas, the regulations of EN 60079-0 apply; whereas for increased safety Ex e
the regulations of EN 60079-7 must be followed. For an approximation of the laws of the EU member states, directive
94/9/EG was created, which is generally known as ATEX 100a and which is the basis for harmonization in this field.
ATEX stands for ”atmoshpere explosive” while 100a refers to the corresponding article of the EC contract.
• Directive ATEX 100a applies for protection against dust and gas explosions in all industrial Ex areas and in mining.
The testing and certificating institutes named in directive ATEX 100a must follow accreditation procedures which are the
same throughout Europe.
• In accordance with EN 60070-0/60079-7 and ATEX 100a, these certifying institutes write out EC certificates for proto­
type tests. These prototype test certificates for components together with the corresponding quality system certification
of the supplier are required to obtain the so-called ATEX approval.
• In combination with the  mark, the markings of the Wieland terminal blocks have the following meaning:
 Identification
II
Device group
2
Category
G D
Areas
KEMA Name of testing institute
ATEX... Certifcate, year of testing, number
Mounting instructions for Ex e applications
• If feed-through blocks are mounted directly adjacent to other feed-through blocks of a different size, or directly adjacent
to ground blocks, the open side of the block group of the same type must be covered by an end plate or partition.
• If adjacent DIN rail terminal blocks are jumpered or if jumpered DIN rail terminal blocks are positioned next to
unjumpered DIN rail terminal blocks, a partition plate must be inserted between the individual terminal block groups or
at the beginning and end of a laterally or longitudinally connected terminal block (group) in order to meet the specified
isolation distances. Notched out and jumpering cross connectors can not be used in Ex areas.
• If the terminal blocks are combined with other certified series and sizes and when their accessories are used, the
required creepage distances and clearances must be adhered to.
• The feed through terminal blocks and protective conductor terminal blocks are suitable for enclosures for use in
explosive gas atmospheres or for use in the presence of combustible dust. For explosive gas atmospheres these
enclosures must satisfy the requirements of EN 60079-0 and EN 60079-7. For combustible dust these enclosures must
satisfy the requirements of EN 61241-0 and EN 61241-1 rather EN 50281-1-1.
• If the DIN rail terminal blocks are installed in a housing with protection type “e” (increased safety) according to
EN 60079-7, the clearances and creepage distances stated in Table 1 must be adhered to..
• The indicated values for the current carrying capability refer to a maximum ambient temperature of 40 °C. When the
terminal blocks are loaded with the maximum rated current the temperature rise will be max. 45 K.
• Operating temperature range: -40° C ... +80° C, series WK(N)/M..., WKF -20° C ... +80° C, series WKFN
• If cables are used whose cross-section is smaller than the nominal cable cross-section, the corresponding lower current
must be specified in the EC prototype test certificate for the complete device.
• Due to the heat generated during operation at the specified current and at ambient temperatures of ≤ 40 °C, the DIN
rail terminal blocks can be installed in equipment (mainly distribution and connection boxes) suitable for temperature
class T6. If DIN rail terminal blocks are installed in equipment with a temperature class ranging from T1 to T5, it must
be ensured that the maximum temperature of the insulating parts does not exceed the maximum value in the operating
temperature range.
143