Steady State, 1Ch, 3A, PAD2 4136/3 Ethernet operated CONTROLLER This package consists of:

Steady State, 1Ch, 3A, PAD2 4136/3 Ethernet operated CONTROLLER This package consists of:
CONTROLLER
Installation and users guide
Rev 1.1 (2012-09-24)
Steady State, 1Ch, 3A, PAD2 4136/3
Ethernet operated
This package consists of:
- PAD2 4136/3, Steady State control unit
- Power/trigger cable, 5m
Specifications
Voltage supply
Current requirement
Protection class
Operation temperature
Storage temperature
Storage humidity
24VDC (±10%)
max. 2A
IP30
0°C ....+65 °C
-40°C....+80 °C
max. 80%
Power output
Light intensity
Communication
max. 3A
0 to 100%.
Ethernet
Warning!
Do not connect to other than 24 V DC!
Power/trigger cable
Yellow
Brown
24 VDC
0V
Pin 1, 2
Pin 3, 4
Green
White
Trigger +
Trigger -
Pin 8
Pin 9
Trigger input: Optically isolated
Range: 5-24 VDC, 20mA.
LED indication
Light head connector:
Pull back the spring-loaded housing before
connecting and disconnecting.
EEC compatibility:
This product, PAD2 4136/3 follow the
EG-directive for EMC-compatibility, 897336,
additional 9321/EEG and 93/86//EEG
Copyright © 2009 LAT elektronik AB • www.latab.se
Member of the Polytec organization
LAT elektronik AB
Krossgatan 18
SE-162 50 Vällingby
Sweden
Phone +046 8704 9225 • e-mail: info@latab.se
CONTROLLER
Installation and users guide
Rev 1.1 (2012-09-24)
Page 2/2, PAD2 4136/3
Adjustable settings:
Long flash mode.
- Light Intensity; 0 - 100 %.
- Double Intensity Mode; 0 - 200 %.
- Ext. On/Off control (or Long Flash) Mode.
This unit can be remotely controlled; light head
ON/OFF, by using the long flash (LF) mode, turning ON and OFF the light by a trigger signal.
As long as the trigger signal is applied the light is
on.
PAD2 4136/3 control protocol
200% light intensity.
The control protocol is of binary type. The commands do NOT utilize header nor termination
characters. All are single byte commands except
”Set Intensity”, requiring two bytes.
The commands are listed below, presented in
HEX format.
1) = Command (cmd):
00 = Turn light head OFF.
01 = Turn light head ON.
02, 00 - FF = Set Intensity, 0 - 100%.
03 = Set External on/off (or LF) mode ON.
A trig. signal is required to turn on the
light. The unit will NOT respond to the on,
off commands in this mode.
04 = Set Double Intensity (DI) mode ON.
05 = Set Normal mode (LF & DI = OFF).
06 = Save settings. All settings stored in
EEPROM to be recalled at power-on.
Controller to host messaging (ASCII):
“OK”: Valid command received and executed.
“S1”: Start of 5 sec. light head shut-down.
“N1”: End of 5 sec. shut-down.
Trigger configuration
Positive edge
Negativ edge
At Double Intensity, 200% (DI) mode, the maximum ON-time is five seconds after which the
controller automatically turns OFF the light head
for five seconds in order to cool down.
Note:
Keeping the unit continuously set to the Double
Intensity mode combined with turned on light
head (from using either cmd 01 or 03 + trig. signal
applied) will result in a slow oscillation turning the
light on and off, in periods of five seconds each.
Ethernet interface:
The Ethernet interface concists of a module
with everything needed housed in a single RJ45
package manufactured by Lantronix.
The unit is factory configured for dynamic IP
addressing. However, a fixed address is recommended when installed in the application.
To assign/change IP address use special soft
ware “Device Installer” on Lantronix.com: http://
ltxfaq.custhelp.com/app/answers/detail/a_
id/644 or available on the USB-mem. stick delivered with the controller.
This software is also helpful when using LATAB
PC-control software. It detects the connected unit
and displays the assigned IP addresses which
is then to be entered into LATAB PC Control.
Please referr to ”ReadMeFirst.doc” for installation
guidence.
Factory default settings:
- IP address: dynamic (other on request).
- Port no 10001.
Copyright © 2009 LAT elektronik AB • www.latab.se
Member of the Polytec organization
LAT elektronik AB
Krossgatan 18
SE-162 50 Vällingby
Sweden
Phone +046 8704 9225 • e-mail: info@latab.se
Was this manual useful for you? yes no
Thank you for your participation!