KEM MKC/MKV
EK036A
Karl Fischer Moisture Titrator [Volumetric titration]
Karl Fischer Moisture Titrator [Coulometric titration]
MKV-710M
Option: Additional Burette KF (10mL)
MKC-710M
SUMMARY
Flagship model
4-channel multi connection/ High extensibility
Karl Fischer Moisture Titrator [Volumetric titration]
Option: Additional Burette KF (10mL)
Midrange model
Smooth operation with touch panel
Karl Fischer Moisture Titrator [Volumetric titration]
Option: Additional Burette KF (10mL)
Entry model
Simplify titration
Karl Fischer Moisture Titrator [Volumetric titration]
Standard: MS-710VP Magnetic Stirrer /
Automatic Solvent Change Unit
Flagship model
4-channel multi connection/ High extensibility
Karl Fischer Moisture Titrator [Coulometric titration]
Midrange model
Smooth operation with touch panel
Karl Fischer Moisture Titrator [Coulometric titration]
Entry model
Simplify titration
Karl Fischer Moisture Titrator [Coulometric titration]
Standard: MS-710C Magnetic Stirrer/
Manual Solvent Change Unit
FEATURE
Wireless connection between operation unit, touch panel, and titration unit/
Simultaneous measurement with up to 4 titration units
MKV-710M
MKC-710M
By the use of wireless adapters (Bluetooth®, Commercialized product),
the operation unit and the titration unit can be used together without
being connected to each other with a cable. You can carry out
titration of a sample, which emits poisonous gas, safely by keeping the
titration unit inside a draft chamber while keeping the operation unit
outside of it. You may place the operation unit on the opposite side of
aisle or hold it with your hand by connecting a battery (Commercialized
product) to it for operation. Attaching a monitor arm to the main
control unit allows for flexibility of its mounting position. (The arm
mount of the display is compliant with VESA standard 75mm x 75mm.)
Wireless 4ch Multi Connection
New-type burette unit
MKV-710M
MKV-710S
MKV-710B
The burette unit has the switching valve on top
of the cylinder. The structure reduces dead
space in the tube between the cylinder and the
switching valve. In addition to the reduction of
dead space in the cylinder, the structure
reduces amount of residual titrant to ease
replacement of titrant.
Option : Reagent Bottle
Maximum electrolysis speed 2.6mgH2O/min
MKC-710M
MKC-710S
Our unique technology
enables maximum
electrolysis speed of
2.6mgH2O/min. It
reduces pre-titration
time and measurement
time.
OPTION
Evaporator ADP-611
This unit vaporizes water content of solid samples,
which is unable to be put directly into the titration
cell, by heating them.
The vaporized moisture is bubbled into the titration
cell to be measured.
Evaporator for Oil Sample ADP-513
Multiple Sample Changer CHK-501
This unit is an evaporator for continuous measurement of
multi samples (24 samples).
Heating temperature can be set for each sample, thus,
different kinds of sample are able to be set at once.
(NON-CE)
Evaporator for Ores ADP-512
This unit is used to measure water content of lubricant
oil, grease, tar products, paints and other viscous liquids.
(NON-CE)
This unit vaporizes adherent water and combined water of
iron ores, manganese ores, clay, and other inorganic
compounds by heating them. (NON-CE)
Heat Extractor for Sugar Samples ADP-344
Evaporator for High Temperature ADP-512S
This unit extracts water content of a sample in the
dehydration solvent by heating the titration cell of
Volumetric Karl Fischer Moisture Titrator. This unit is
used to measure the water content of chocolates,
caramels and other sugar samples. (NON-CE)
This unit has heating capacity up to 1000℃ and is used
to measure combined water, etc.
(NON-CE)
SPECIFICATION
Specification
Contents
Type
Karl Fischer Moisture Titrator
Model
MKV-710M
MKV-710S
MKV-710B
Product configuration
MCU-710M+MKV-710+IDP-100+
MCU-710S+MKV-710+IDP-100+
MKV-710+IDP-100+Automatic Solvent
Automatic Solvent Change Unit
Automatic Solvent Change Unit
Change Unit
Measuring method
Measuring range
Karl Fischer Volumetric titration
1) Water content : 0.1 to 500mgH2O (depends on KF reagent factor)
2) Concentration : 10ppm to 100%H2O
Burette precision
Volume
: 10mL burette
Discharge precision : ±0.015mL Repeatability
Endpoint detection
EP sense method
Detection of potential level maintained during preset end time
End time range
Titration form
: ±0.005mL
By polarized potential level detected with a twin platinum electrode
: 1 to 99s
Normal titration / Back titration (Option additional burette required)
Required solvent
30 to100mL (in S-type titration vessel)
Method
120
Key operation
Touch panel
Sheet key
Displays
1) 8.4-inch color LCD 800 × 600 dots
1) White LED-backlit LCD
2) English / Japanese / Mandarin Chinese / Korean / Russian / Spanish /
2) English / Japanese / Mandarin Chinese
20
German / French
/ Korean / Russian / Spanish
3) Simultaneous 4-channel display
3) 1-channel display
3) 1-channel display
(Can also display Automatic
Potentiometric Titrator
simultaneously)
Calculation
Concentration of water content, statistics data processing (mean, SD and RSD) and automatic averaging of blank value and
factor value
Data storage
500 samples
GLP conformance
Registration of operator / User group administration Titrant: Reminder of factor
100 samples
Registration of operator / Record of
measurement date / Alarm to indicate remaining reagent / Reminder of piston
check results / Record of factor
replacement date / Reminder of reagent replacement date / History of factor
measurement / Management of
measurement Check performance: Reminder of scheduled check date / Record of
conduction time
check results
Management of conduction time : Display of operating time
External I/O
RS-232C port × 4
RS-232C port × 2
for Dot matrix printer, Electronic balance, Data Capture Software (SOFT-CAP),
for Dot matrix printer, Electronic balance,
Evaporator
Data Capture Software (SOFT-CAP)
USB×1
USB×1
for USB flash drive, Thermal printer, A4 printer, Keyboard, Barcode reader,
for USB flash drive, Thermal printer,
Foot switch, USB HUB
Keyboard, Barcode reader, Foot switch,
USB HUB, Android device
SS-BUS × 1 : for APB
LAN×1 : for Personal computer (PC)
Extensibility
Measuring instrument : Automatic
Potentiometric Titrator (AT-710),
Karl Fischer Moisture Titrator
(MKV-710/MKC-710); Three of these
instruments can be added.
Automatic piston burette : Can control max 2 burette drives (Including two built-in burette drives)
Evaporator ADP-611
Ambient condition
1) Temperature
: 5 to 35℃
2) Humidity
: 85%RH or below (no condensation)
Power source
AC100 - 240V ±10% 50/60 Hz
Power consumption
Main unit
: Approx. 30W
Main unit
: Approx. 20W
Printer
: Approx. 7W
Printer
: Approx. 7W
Dimensions
Weight
Conformity standard
Touch panel controller
: 225(W) × 190(D) × 42(H) mm
Titration unit
: 141(W) × 292(D) × 367(H) mm (not incl. tubing)
Stirrer
: 107(W) × 206(D) × 322(H) mm (not incl. Solvent Change unit)
Solvent Change Unit
: 240(W) × 140(D) × 400(H) mm (not incl. tubing)
Printer
: 106(W) × 180(D) × 88(H) mm
Touch panel controller
: Approx.1.5kg
Titration unit
: Approx.4.0kg
Stirrer
: Approx.2.0kg
Solvent Change Unit
: Approx.0.6kg
Printer
: Approx.0.4kg
CE marking EMC : EN61326-1 LVD: EN61010-1 RE Directive
Burette unit EBU FCC Part15 SubpartC FCC ID: 2ABSVEBU01
SPECIFICATION
Specification
Contents
Type
Karl Fischer Moisture Titrator
Model
MKC-710M
MKC-710S
Product configuration
MCU-710M+MKC-710+IDP-100+Manual
MCU-710S+MKC-710+IDP-100+Manual
MKC-710+IDP-100+Manual Solvent
Solvent Change Unit
Solvent Change Unit
Change Unit
Measuring method
Karl Fischer Coulometric titration
Measuring range
Water content / Bromine index : 10ug to 300mg (depends on reagent)
Measurement cell
2-Component or 1-Component
Precision
MKC-710B
Relative standard deviation : less than 0.3% (n=10)
*Per KEM standard measurement conditions and standard liquids
Display resolution
0.1ug
Control method
Constant current pulse time control
Endpoint detection
Alternate current polarization method with a twin platinum electrode
EP sense method
Selective drift stability or limit measurement time
Required solvent
Anolyte 100mL (max 150mL)
Catholyte 5mL
Method
120
Key operation
Touch panel
20
Sheet key
Displays
1) 8.4-inch color LCD 800 × 600 dots
1) White LED-backlit LCD
2) English / Japanese / Mandarin Chinese / Korean / Russian / Spanish /
2) English / Japanese / Mandarin Chinese
German / French
/ Korean / Russian / Spanish
3) Simultaneous 4-channel display
3) 1-channel display
3) 1-channel display
(Can also display Automatic
Potentiometric Titrator
simultaneously)
Calculation
Concentration of water content, statistics data processing (mean, SD and RSD) and automatic averaging of blank value
Data storage
500 samples
100 samples
GLP conformance
Registration of operator / User group administration Check performance with
Registration of operator / Check
standard substance: Reminder of scheduled check date / Record of check results
performance with standard substance /
External I/O
Reagent life control: Reminder of expiration / Reminder of reagent replacement
Reagent life control / Management of
date Management of conduction time : Display of operating time
conduction time
RS-232C port × 4
RS-232C port × 2
for Dot matrix printer, Electronic balance, Data Capture Software (SOFT-CAP),
for Dot matrix printer, Electronic balance,
Evaporator, Multiple sample changer
Data Capture Software (SOFT-CAP)
USB × 1
USB × 1
for USB flash drive, Thermal printer, A4 printer, Keyboard, Barcode reader, Foot
for USB flash drive, Thermal printer,
switch, USB HUB
Keyboard, Barcode reader, Foot switch,
USB HUB, Android device
LAN × 1 : for Personal computer (PC)
Extensibility
Measuring instrument : Automatic
Potentiometric Titrator (AT-710),
Karl Fischer Moisture Titrator
(MKV-710/MKC-710); Three of these
instruments can be added.
Evaporator : ADP-611
Multiple sample changer : CHK-501
Ambient condition
1) Temperature
: 5 to 35℃
2) Humidity
: 85%RH or below (no condensation)
Power source
AC100 - 240V ±10% 50/60 Hz
Power consumption
Main unit
: Approx. 30W
Main unit
: Approx. 20W
Printer
: Approx. 7W
Printer:
: Approx. 7W
Dimensions
Weight
Conformity standard
Touch panel controller
: 225(W) × 190(D) × 42(H) mm
Titration unit
: 141(W) × 292(D) × 244(H) mm
Stirrer
: 107(W) × 206(D) × 340(H) mm (not incl. Solvent Change unit)
Solvent Change Unit
: 240(W) × 140(D) × 405(H) mm (not incl. tubing)
Printer
: 106(W) × 180(D) × 88(H) mm
Touch panel controller
: Approx.1.5kg
Titration unit
: Approx.3.0kg
Stirrer
: Approx.2.0kg
Solvent Change Unit
: Approx.0.6kg
Printer
: Approx.0.4kg
CE marking EMC : EN61326-1 LVD: EN61010-1
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising