Model 3150

Model 3150
AUTOMATIC IRON FILTER SYSTEMS
MEDIUM FLOW COMMERCIAL 3150 SERIES
Standard Features:
Time Clock Control
2” Female Inlet/Outlet Connections
Fleck 3150 Lead-Free Brass Valve
Motor-Driven Piston-Operated
Fiberglass Resin Tank (s)
Ports for Pressure Gauges & Sample Valves
Birm Systems provide an effective method of removing dissolved iron and manganese from water supplies. It performs
best when there is a sufficient amount of dissolved oxygen in
the feed water supply.
Physical Properties
Color:
Mesh Size
Bulk Density
Black
10 x 40
40-45 lbs/cf
Operating Considerations
Feed Water pH Range
6.8 – 9.0
Free Chlorine
Less than 0.5 ppm
Dissolved Oxygen must equal 15% of iron content.
Alkalinity must be greater than 2x then combined sulfate and
chloride concentration
Model 3150TBI100HL
PRODUCT SPECIFICATIONS (per unit)
Model
Series
Media Qty
Cubic Feet
Sq. Ft.
Bed Area
Media Tank
Dia. X Ht
3150TBI1000HL
10
3.14
3150TBI500STD
15.0
3150TBI2000HL
3150TBI3000HL
Service Operating Conditions
Continuous Service
Flow
PSI
Drop
Max Drain Flow
Tank and Valve Dimension
Diameter x Height
24” x 72”
16 gpm
5
35
24” x 82”
4.91
30” x 72”
25 gpm
8
60
30” x 82”
20.0
7.07
36” x 72”
35 gpm
9
85
36” x 82”
30.0
9.62
42” x 88”
48 gpm
12
105
42” x 98”
Service fl ow rate is 3.5 to 5 gom/sq.ft. Intermittent fl ow rates and /or favorable local conditions may allow higher fl ow rates
Specifi cations are subject to change without notice
ADDITIONAL OPERATING INFORMATION
For use on potable water only.
Not intended to be used to treat water that is micro biologically unsafe or of unknown quality.
Installation must comply with all state and local codes.
psi
Tank dimensions are based on fiberglass only. Steel tanks dimensions will vary.
operating
Pressure drops are based on clean filter bed.
®
Operating Water Temperature Range
Operating Ambient Temperature Range
Operating Pressure Range
Electrical Requirements
Feedwater Turbidity
Chlorine
Iron
Max 100°
Max 120°
Max 125 psi
110V-60Hz primary
Minimum 35°
Minimum 35°
Minimum 20 psi
24v-60hz
5.0 N.T.U. Max
1.0 mg/l Max
>5 mg/l Consult Aqua Systems
Aqua Systems Commercial & Industrial • 114 Vista Parkway • Avon, Indiana 46123
317-272-6715 • 800-997-5492 • Fax 317-272-6728
www.aquasystemsci.com • e-mail: commercialindustrial@aquasys.biz