SuperCat7 S

SuperCat7 S
SuperCat7_23_S_FTP_Install
22.07.2009
Page 1 of 3
SuperCat 7 HS23 Cat.7
S/FTP Installation Cable for Indoor/Outdoor use
Application
Indoor and Outdoor installations. Filled with compound to prevent water penetration
Primary (Campus), Secondary (Riser), Tertiary (Horizontal)
IEEE 802.3: 10Base-T; 100Base-T; 1000Base-T; 10GBase-T
IEEE 802.5 16 MB; ISDN; TPDDI; ATM
Standards
EN 50173-1; EN 50288-4-1
ISO/IEC 11801; IEC 61156-5
Water penetration rating
IEC 60794-1-2F5, methode B
Fire rating
Flame retardant and Halogen free:
Smoke classification : No
IEC 60332-1; IEC 60754-2
Construction
Conductor
Solid bare copper wire, Ø 0.55 mm (AWG 23)
Insulation
Foamskin PE, Ø 1.45 mm
Twisting
2 cores to the pair, WBC filled
Pair screen
Al-laminated plastic foil
Cable lay up
Screen
4 pairs (PiMF) to the core, swelling yarn and tape
Special Waterproofing/compound to prevent moisture migration*). To prevent water penetration and to ensure
electrical properties even in continous wet conditions.
Copper braid, tinned
Sheath
LSHF, Black, UV stabilized
Cable core filling
We reserve the right to alter this specification without notice
*)Patent Pending
SuperCat7_23_S_FTP_Install
22.07.2009
Page 2 of 3
SuperCat 7 HS23 Cat.7
Mechanical properties
Bending radius
During operation
4 x Outer diameter
During installation
8 x Outer diameter
Temperature range
During operation
-40°C to + 60°C
Maximum tensile load
During installation
During operation
During installation
-10°C to + 50°C
100 N
Electrical properties
at 20°C± 5°C
≤ 165 Ω/km
Loop resistance
≤ 2%
Resistance unbalance
≥ 2000 MΩ*km
Nom. 43 nF/km
Insulation resistance
(500 V)
Mutual capacitance
at 800 Hz
Capacitance unbalance
(pair/ground)
Characteristic impedance
(1-100 MHz)
≤ 1500 pF/km
(100 ± 15) Ω
(100 - 250) MHz
(100 ± 18) Ω
(250 - 600) MHz
(100 ± 25) Ω
Nominal velocity of propagation
ca. 79 %
Propagation delay
≤ 550 ns/100m
Test voltage
(DC, 1 min) core/core and core/screen
≤ 10 ns/100m
1000 V
Transfer impedance
at
1 MHz
≤ 20 mΩ/m
at 10 MHz
≤ 30 mΩ/m
Delay skew
at 30 MHz
≤ 40 mΩ/m
at 100MHz
≤ 200 mΩ/m
≥ 75 dB
Coupling attenuation
Electrical data (nominal)
at 20°C
F
(MHZ)
1.0
Attenuation
(dB/100m)
1.8
NEXT
(dB)
100
PS-NEXT
(dB)
97
ACR
(dB/100m)
98
PS-ACR
(dB/100m)
95
ELFEXT
(dB/100m)
105
PS-ELFEXT
(dB/100m)
105
Return loss
(dB)
-
4.0
3.4
100
97
97
94
105
102
27
10.0
5.4
100
97
95
92
97
94
30
16.0
6.8
100
97
93
90
93
90
30
20.0
7.7
100
97
92
89
91
88
30
31.2
9.6
100
97
90
87
87
84
30
62.5
13.7
100
97
86
83
81
78
30
100.0
17.4
100
97
83
80
77
74
30
125.0
19.5
95
92
75
72
75
72
26
155.5
21.9
94
91
72
69
73
70
26
175.0
23.3
93
90
70
67
72
69
25
200.0
25.0
92
89
67
64
71
68
25
250.0
28.1
90
87
62
59
69
66
24
300.0
30.9
89
86
58
55
67
64
24
450.0
38.3
87
84
48
45
64
61
23
600.0
44.8
85
82
40
37
61
58
22
750.0
52.0
83
80
31
28
59
56
21
900.0
59.4
82
79
23
20
58
55
20
We reserve the right to alter this specification without notice
*)Patent Pending
SuperCat7_23_S_FTP_Install
22.07.2009
Page 3 of 3
SuperCat 7 HS23 Cat.7
Technical Data
Product name
Colour
Black,
SuperCat 7 23 Cat.7 S/FTP 4P LSHF RAL9011
Outer diameter
Fire load
Weight
mm
MJ/km
kg/km
8,7
838
65
Delivery
form
Material code
DCN no.
El. no
x
1006237 00500DP
799580
x
We reserve the right to alter this specification without notice