ICON CP Manual
INSTALLATION AND OPERATION MANUAL
ICON-CP
IMPORTANT SAFETY INFORMATION
PRÉCAUTIONS DURANT UTILISATION
1.
Read these instructions.
1.
LISEZ ces instructions.
2.
Keep these instructions.
2.
Tenez ces instructions.
3.
Heed all warnings.
3.
Notez tous les avertissements.
4.
Follow all instructions.
4.
Suivez toutes les avertissements.
5.
Do not use this apparatus near water.
5.
N’utilisez pas ce produit près de l’eau (la piscine, la plage, le lac, etc.).
6.
Clean only with dry cloth.
6.
Nettoyez seulement avec une étoffe sèche.
7.
Do not block any ventilation openings. Install in accordance with the
manufacturer’s instructions.
7.
Ne bloquez aucuns troux de ventilation. Installez en accord avec
les instructions du manufacturier.
8.
Do not install near any heat sources such as radiators, heat registers,
stoves, or other apparatus (including amplifiers) that produce heat.
8.
9.
Do not defeat the safety purpose of the polarized or grounding-type plug.
A polarized plug has two blades with one wider than the other.
A grounding type plug has two blades and a third grounding prong.
The wide blade or the third prong are provided for your safety. If the
provided plug does not fit into your outlet, consult an electrician for
replacement of the obsolete outlet.
N’installez près aucunes sources de chaleur comme radiateurs, registres
de chaleur, fours ou les autres équipements (y compris amplificateurs)
qui produisent la chaleur.
9.
Ne défaites pas le but de sécurité de la fiche polarisée ou base-type.
Une fiche polarisée a deux tranchants avec un plus large que l’autre.
Une fiche de base type a deux a deux tranchants et une troisième
pointe de base, le tranchant large ou la troisième pointe est fourni
pour votre sécurité. Si la fiche donnée ne conforme pas votre prise
de contact, consultez un électricien pour remplacement de la prise
de contact obsolète.
10. Protect the power cord from being walked on or pinched particularly
at plugs, convenience receptacles, and the point where they exit from
the apparatus.
11. Only use attachments/accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by the
manufacturer, or sold with the apparatus. When a cart is used, use caution
when moving the cart/apparatus combination to avoid injury from tip-over.
13. Unplug this apparatus during lightning storms or when
unused for long periods of time.
14. Refer all servicing to qualified service personnel.
Servicing is required when the apparatus has been
damaged in any way, such as power-supply cord or plug
is damaged, liquid has been spilled or objects have fallen into the
apparatus, the apparatus has been exposed to rain or moisture, does
not operate normally, or has been dropped.
15. This appliance shall not be exposed to dripping or splashing water and
that no object filled with liquid such as vases shall be placed on the
apparatus.
16. Plug this apparatus to the proper wall outlet and make the plug to be
disconnected readily operable.
17. Main plug is used as disconnected device and it should remain readily
operable during intended use. In order to disconnect the apparatus from
the mains completely, the mains plug should be disconnected from the
mains socket outlet completely.
18. WARNING: To reduce the risk of fire or electric shock, do not expose this
apparatus to rain or moisture.
19. An appliance with a protective earth terminal should be connected to a
mains outlet with a protective earth connection.
10. Protegez le cordon de secteur contre être marchée dessus ou pincez
en particulier aux fiches, aux douilles de convenance, et au point où ils
sortent de l’appareil.
11. Seulement utilisez attachements/accessoires spécifiés par le
manufacturier.
12. Utilisez seulement avec un chariot, un stand, un trépied, un support
ou une table indiquée par le manufacturier, ou vendue avec l’appareil.
Quand un chariot est utilisé, faites attention en déplaçant la combinaison
d’appareil/chariot pour éviter de se déséquilibrer.
13. Arrachez la fiche du dispositif durant éclair et orage ou
quand pas utilisé pour longues périodes de temps.
14. Référez au personnel qualifié de service pour toutes
réparations. La réparation est donnée quand le système
a été endommagé à n’importe façon, par exemple un fil ou une fiche
endommagé(e) de la source d’alimentation. Avoir été exposé à pluie ou
humidité, n’opère pas normalement, ou avoir été tombé.
15. L’appareil ne doit pas être exposé aux écoulements ou aux éclaboussures
et aucun objet ne contenant de liquide, tel qu’un vase, ne doit être placé
sur l’objet.
16. Branchez l’appareil à une source appropriée et faire que la prise à
débrancher soit facilement accessible.
17. La prise du secteur ne doit pas être obstruée ou doit être facilement
accessible pendant son utilisation. Pour être complètement déconnecté
de l’alimentation d’entrée, la prise doit être débranchée du secteur.
18. AVERTISSEMENT: Pour éviter le risque d’incendie ou de chocs électriques,
ne pas exposer cet appareil à la pluie ou à l’humidité.
19. Un appareil avec la borne de terre de protection doit être connecté au
secteur avec la connexiion de terre de protection.
PAGE 2
ICON-CP MANUAL
INTRODUCTION AND CONTENTS
ICON-CP
INTRODUCTION
3
The ICON control panel is both elegant and ergonomic to suit
today’s modern installations.
ICON-CP AND REVOLUTION SERIES
4
The ICON CP controls a number of Australian Monitor products &
will also be compatible with a number of new products making the
unit flexible and future proof.
ICON-CP AND AMD100-200
5
ICON-CP AND IN600
6
The ICON control panel is programmable to allow for a host of
configurations and control options all from the one control panel.
DIMENSIONS
7
Revision 1.2 August 2010
WARNING!
TO PREVENT FIRE OR SHOCK HAZARD, DO NOT USE THE PLUG WITH
AN EXTENSION CORD, RECEPTACLE OR OTHER OUTLET UNLESS THE BLADES
CAN BE FULLY INSERTED TO PREVENT BLADE EXPOSURE.
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE
THIS APPLIANCE TO RAIN OR MOISTURE.
TO PREVENT ELECTRICAL SHOCK, MATCH WIDE BLADE PLUG TO WIDE SLOT, FULLY INSERT.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
The lightning flash with arrowhead symbol,
within an equilateral triangle, is intended
to alert the user to the presence of
uninsulated “dangerous voltage” within
the product’s enclosure that may be of
sufficient magnitude to constitute a risk
of electric shock to persons.
WARNING: TO REDUCE THE RISK
OF ELECTRIC SHOCK, DO NOT
REMOVE COVER (OR BACK).
NO USER SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL.
The exclamation point within an equilateral
triangle is intended to alert the user to
the presence of important operating and
maintenance (servicing) instructions in the
literature accompanying the appliance.
Rating plate and caution marking are marked on the back enclosure of the apparatus
ICON-CP MANUAL
PAGE 3
ICON-CP AND REVOLUTION SERIES
The Revolution series control panels (ICON-CP) have two banks of DIP switches
on the rear of the control panel. The first bank of switches labeled SW1 allows
the user to address the panel for RS485 communications. The second bank of
switches allows the user to set up the LED functions for the remote panel.
SW1:
RS485 addresses 1-240 are allowed. With any other address the unit will blink
its error LEDs.
1
2
4
8
16
32
64
128
SW1 Address
SW2 Func
A
B
C
D
ICON-CP Control Panel
fail or be broken it could simply be swapped out with a unit set to the same
address. All control panels are constantly polling the RS485 network for status.
This will allow the user to update settings via 3rd party, other control panels or
the software GUI and have all panels constantly up to date.
Each RS485 port on the Revolution series allows you to run up to 20 control
panels to a maximum distance of 500 metres. With each unit featuring two
RS485 ports, this allows the AV Revolution to run up to 40 ICON-CP’s on two
separate 500m runs. The 500m limitation of the control panels is due to power
loss over distance and not RS485 limitations therefore if lengths longer than
500m are required you need to inject power locally for greater distances.
SW2
A: ON = LED brightness varies based on ambient light, OFF = Fixed Brightness
B: ON = Low brightness (if switch A is on fixed brightnes mode), OFF = Normal
Brightness
C: Unused on Revolution series
D: Unused on Revolution series
The ICON-CP control panels do not hold any project data so if a panel was to
PAGE 4
ICON-CP MANUAL
ICON-CP AND AMD100-200
The ICON-CP can be used to control certain functions of the AMD100/200.
The set up the control panel all you need to do is address the panel on SW1.
Switch 1-8 represent a binary address. For example to address it to ID1 all you
need to do is have number 1 on, to address it to 3 have switch 1 and 2 on.
1. BGM 1
SW2 C and D do not do anything, A and B adjust the LED settings of the panel.
With switch A high ambient light adjustment will be turned on. With switch B on,
low brightness mode will be activated. Only one switch should be up at a time.
3. BGM 3
2. BGM 2
4. BGM 4
5. BGM Off
ID 1: (Switch 1 On)
6. BGM Mute
In this mode the first 5 buttons act as a source select (1-4 and off)
7. BGM Vol +
The 6th button acts as a mute control
Buttons 7 and 8 are volume up and volume down for the BGM source
8. BGM Vol -
NOTE:
BGM Off deselects all the BGM input.
BGM Mute toggles and maintains the selected BGM source for easy unmuting.
1. Mic\Line 1
2. Mic\Line 2
ID 2: (Switch 2 On)
3. Mic\Line 3
In this mode the panel acts as 6 individual volume controls.
4. Mic\Line 4
The first 6 buttons pick the volume you want to control and the bottom two buttons are
volume up and volume down.
5. BGM
6. Master
+ Volume
- Volume
1. Mic\Line 5
2. Mic\Line 6
ID 3: (Switch 1 and 2 On)
3. Mic\Line 7
This mode is the same as two but controls different sources.
Note, this is will work on AMD200 only.
4. Mic\Line 8
5. BGM
6. Master
+ Volume
- Volume
ICON-CP MANUAL
PAGE 5
ICON-CP AND IN600
With the ICON-CP’s DIP switch bank 2(FUNC) set with D on the ICON-CP will control the
AMAV IN600.
The control parameters are fixed to three different configurations. These are:
1. Source 1 (DVD1)
2. Source 2 (DVD2)
3. Source 3 (AUX1)
Address ID 1: (Switch 1 On)
With this setting you get control over selection of the sources and also volume control
of the source mixer. When a source is selected after already being active the unit will
switch the source to “Off”
4. Source 4 (AUX2)
5. Source 5 (PC1)
6. Source 6 (PC2)
Address ID 2: (Switch 2 On)
7. Source Volume Up
With this setting you have control over turning the projector on and off. You can also turn
each microphone on by triggering its mute control. The volume control will control the
mic mixer level on the unit.
8. Source Volume Down
Address ID 1: (Switch 1 On)
Address ID 3: (Switch 1 and 2 On)
With this setting selected you have the exact same controls as ID2 except the
microphone mute controls are inversed so that the active state will have the
microphone off.
1. Projector On
2.
Projector Off
3.
Mic 1 On
Powering the ICON-CP
The ICON-CP remote panels will need to be externally powered when being used with
the IN600. As these units have RJ45 looped in and outs we now provide a 24V DC
power injector that simply has a data in and a P+Data out. It is recommended that this
unit be placed close to the ICON-CP, all you need to do is run from the IN600 into the
power injector then out to your run of remote panels.
4. Mic 2 On
5. Mic 3 On
6. Mic 4 On
7. Mic Volume Up
Connecting to the IN600
8. Mic Volume Down
When wiring the ICON-CP panels we suggest simply using premade cables if possible
or if terminating your own to follow one standard the whole way that will allow your
connections to be pin to pin from the start to the end.
Address ID 2: (Switch 2 On)
The IN600 has a terminal block for the RS485 bus. The pin out needed to connect the
ICON-CP to the IN600 is below:
1. Projector On
Data line A = Pin 3 of the ICON-CP
2.
Projector Off
Data line B = Pin 6 of the ICON-CP
3.
Mic 1 Off
Gnd line = Pin 2 of the ICON-CP
4. Mic 2 Off
5. Mic 3 Off
6. Mic 4 Off
7. Mic Volume Up
8. Mic Volume Down
Shown with
locking clip
facing
White/Green 1
Green 2
White/Orange 3
Blue 4
White/Blue 5
Orange 6
White/Brown 7
Brown 8
Address ID 3: (Switch 1 and 2 On)
CABLE
568A configuration
PAGE 6
ICON-CP MANUAL
DIMENSIONS
ICON-CP MANUAL
PAGE 7
ENGINEERED BY AUSTRALIAN MONITOR
Address: 1 Clyde Street, Silverwater, Sydney NSW 2128 Australia. Private Bag 149, Silverwater NSW 1811 ABN 78 001 345 482
Website: www.australianmonitor.com.au International enquiries email: international@australianmonitor.com.au
DISTRIBUTED IN AUSTRALIA AND NEW ZEALAND BY HILLS SVL www.hillssvl.com.au
NSW
P: 02 9647 1411
E: nsw@hillssvl.com.au
QLD
P: 07 3852 1312
E: qld@hillssvl.com.au
ACT
P: 02 6260 4544
E: act@hillssvl.com.au
WA
P: 08 9204 0200
E: wa@hillssvl.com.au
VIC
P: 03 9890 7477
E: vic@hillssvl.com.au
SA
NZ
P: 08 8408 8300
P: 09 415 9426
E: sa@hillssvl.com.au E: sales@hillssvl.co.nz