VID-02P-manual
UTP (unshielded twisted pair) Passive Video Transceiver
Installation Instructions
General
This manual is a guide to the installation and operation of the VID-02P model VIDIPAC UTP.
Please read the entire manual before installing.
Brief description
VID-02P model is a single channel passive transceiver with screw-less Terminal block and built-in transient protection. VID-02P
Passive Balun allows a single CCTV video signal to be transmitted via cost-effective Unshielded Twisted Pair (UTP) cable. Used
in pair, the UTP CCTV passive balun can connect the CCTV security and surveillance equipments using standard structured
cabling techniques for neater and more streamlined cabling instead of costly and bulky coaxial cable.
VID-02P is small in size and can be fixed with outer housing of a camera. It also works in conjunction with other VIDIPAC
passive transceivers and passive hubs.
Features of VID-02P
• PAL, NTSC, SECOM video compatible
• Passive device, no power required
• Transmission range: Colour signal up to 225m* working with passive transceivers
• Screw-less Terminal block reduces wiring time
• High crosstalk and noise immunity
• Compact size with BNC-male connector
• One year warranty
Technical specifications
Model
Vidipac VID-02P
Bandwidth
Video
Cable Type
Environmental
Insertion Loss
0.5dB
CMMR
Typical 60dB
Anti-transient Ability
6000V 1.2μS×50μS
Coaxial Cable
75ohm
Coaxial Connector
BNC-male
UTP Connection
Quick-connect screwless terminal block
Specification*
UTP 24AWG minimum, Cat-3 upwards, 225m* maximum
distance PAL & 300m maximum NTSC for CAT-5
Resistance
100ohm±20%
DC Loop Resistance
18ohm/100m
Differential Capacitance
62pf/m
Temperature
Operating: -20° to 70° C
Humidity
0~95%
Mechanical:
Mechanical
DC-6MHz
Weight Weight
Dimensions - overall of
Dimensions
balun
22g
22g
Length
!Width
20mm
62mm 62mm
(L) × 20mm
(W) × 18mm
(H)! Height 18mm
Mechanical Drawing
Mechanical Drawing
Installation
Caution
• Unshielded Twisted Pair (UTP) wires must be used. Note: Shielded
twisted pair wires cause impedance mismatch
• Make sure there are no untwisted wires as it may result in distorted
image and interference.
• Each video signal must use the same twisted pair.
Installation
Caution
• Unshielded Twisted Pair (UTP) wires must be used. Note: Shielded twisted pair wires cause impedance mismatch
• Make sure there are no untwisted wires as it may result in distorted image and interference.
• Each video signal must use the same twisted pair.
• Make sure there are no extra branch (or star connection) of twisted pair as it results in ghost image. Always connect the
transceivers with pointto-point Unshielded Twisted Pair wires.
• Coaxial cable length between the video equipment and the passive UTP transceiver balun must not exceed 1.8m.
Transceiver installation
• Connect the VID-02P passive transceivers as close as possible through the coaxial cable to the video equipments (Camera,
monitors, VCRs, DVRs, etc.)
• VID-02P passive transceivers have ‘+’ and ‘-’ terminals.
• Use a pair of Unshielded Twisted Pair (UTP) wires to connect the transceivers
• Make sure the ‘+’ of one transceiver is connected to the ‘+’ of another transceiver and vice versa for the ‘-’ terminal.
Connection Diagram
Transceiver performance table for UTP video within 225m
Transceiver
Receiver
Distance
Antiinference
Power
Supply
Floating
NO
NO
TransceiverVID-02P
performance table for UTP video within 225m
Surge
Protection
VID-03P
VID-02P
Transceiver
VID-Hub-04P
VID-Hub-08P
Receiver
Up to 225m
Distance
VID-Hub-16P
VID-02P
VID-02P
Troubleshooting
VID-02P
VID-03P
YES
Antiinference
Power
Supply
YES
Floating
Up to 225m
Up to 225m
• No Signal on the Monitor. Make sure
VID--HubUp to 225m
VID-02P
 Terminal are well
connected
04P
YES
NO
NO
 Same pair of UTP
wire is used
VID--HubVID-02P
Up to 225m
• Twisted
image. Make Sure08P
 ‘+’ terminal is connected
to ‘+’ and vice versa for ‘-’
VID--HubVID-02P
Up to 225m
16P red and a red bar moves downward. Make sure
• The video image is somewhat
 BNC connector is well connected
 Equipments are well grounded
• The video
is not stable and has ghost effect. Make sure
Troubleshooting
 There
are no
extra branch
(or star
connection)
from the
twisted pair
• No
Signal
on the
Monitor.
Make
sure
 A single length
UTP
wire
is
used
! Terminal are well connected
• Noisy image. Make sure
! Same pair of UTP wire is used
 There are no untwisted UTP wires to avoid interference
• Attenuated image. Make sure
• Twisted image. Make Sure
 Coax length is less than 1.8m
! ‘+’ terminal is connected to ‘+’ and vice versa for ‘-’
 UTP length is less than 225m
• Distorted image. Make sure
• The video image is somewhat red and a red bar moves downward.
 To use UTP wires Cat3 upwards to avoid impedance mismatch.
Make sure
! BNC connector is well connected
! Equipments are well grounded
•
Surge
Protection
The video is not stable and has ghost effect. Make sure
! There are no extra branch (or star connection) from the twisted
pair
YES
With sales and support from over 22 Locations
Was this manual useful for you? yes no
Thank you for your participation!