IG_Sensor_DataSheets
SENSORS FRONIUS IG - SERIES
Page:
1/4
Date: 6/20/2003
AMBIENT TEMPERATURE SENSOR
By having a wide temperature measurement range, the
ambient temperature sensor is well suited for measuring
both outdoor and indoor temperatures.
TECHNICAL DATA
Sensor
PT1000
Measuring range
-40°C to +180°C; -40°F to 356°F
Accuracy
± 0.8°C (in the range -40°C to 100°C)
± 1.5 °F (in the range -40°F to 212°F)
Design
Sensor enclosed in a cylindrical housing of stainless steel
Dimensions
Length 2 in (50mm), ∅ 0.24 in (6mm)
Cable
Max. cable length (distance:
Sensor Card/Box – sensor)
Fronius Art. Nr.
9.8 ft (3m) Cu-cable, 7.8 x 2 mil (2 x 0,5 mm), silicon
isolated, ferrules, UV rated
65 ft (20m)
43,0001,1188
Installation tip: For this sensor, there are no special mounting requirements. The ambient
temperature sensor can simply be installed under the pv-modules.
SENSORS FRONIUS IG - SERIES
Page:
2/4
Date: 6/20/2003
MODULE TEMPERATURE SENSOR
This sensor measures the surface temperature of the pvmodules. By affixing the sensor to the backside of the pv-module,
the module temperature can be measured.
Module temperature can affect power output. By measuring
module temperature one can monitor the effects on the solar
system’s performance.
TECHNICAL DATA
Sensor
PT1000
Measuring range
-4 °F to +302 °F
Accuracy
Design
± 0.8°C (in the range –20°C to 100°C)
± 1.5 °F (in the range – 4 °F to 212 °F)
Sensor on an adhesive film for measurement on
module back sheets
Dimensions
2 x 1 in (50 x 100 mm)
Cable
9.8 ft (3m) Cu-cable, silicon isolated, ferrules, UV rated
Max. cable length (distance:
Sensor Card/Box – sensor)
Fronius Art. Nr.
65 ft (20m)
43,0001,1190
Installation tip: It is recommended to attach the sensor and cable
with additional strain-relief using heat resistant adhesive tape.
SENSORS FRONIUS IG - SERIES
Page:
3/4
Date: 6/20/2003
IRRADIATION SENSOR
This sensor is designed for measuring solar irradiated energy. In
most cases the sensor is mounted on the frame of the solar
module.
Comparing the amount of irradiated power with the power
produced by the inverter provides a detailed analysis on the
performance of the pv-system.
TECHNICAL DATA
Sensor
Sensor voltage
Mono crystalline Si-Sensor
approx. 70mV at 1000W/m2
(Calibration constant is written on the sensor)
Accuracy
± 5% (average over a year)
Ambient temperature
-40°C to +85°C; -40 °F to 185 °F
Design
Sensor is mounted on a Z-shaped aluminium profile
Dimensions
l x w x h = 14.2 x 1.6 x 1.6 in (110 x 40 x 40 mm)
Cable
9.8 ft (3m) Cu-cable, ferrules, UV rated
Max. cable length (distance: Sensor
Card/Box – sensor)
Fronius Art. Nr.
100 ft (30m)
43,0001,1189
Installation tip: The sensor comes attached to an aluminium profile
with an 0.315 in (8 mm) hole making it easy to attach to a fixed
surface like a module frame. Make sure that the sensor does not cast
any shadow on the module.
SENSORS FRONIUS IG - SERIES
Page:
4/4
Date: 6/20/2003
WIND SPEED SENSOR
The sensor measures the wind speed at a specific pv-system
location.
Used to determine wind load and analyze pv-system cooling
capacity, this sensor can be used in combination with other
sensors to make an almost complete weather station.
TECHNICAL DATA
Sensor
Cup Anemometer
Output signal
Rectangle: Low ≤ 0.5V / High ≥ 3.5V
Calibration factor
1.45 Hz = 1.6 mph (1km/h)
5.22 Hz = 3.28 ft/ sec (1m/s)
Threshold
8.2 ft/sec (2,5m/s) wind speed
Resolution
3.28 ft/sec; 0.621 mph(1m/s; 1km/h)
Accuracy
± 5% at wind speed ≥ 16.4 ft/sec (5m/s)
Protection Type
IP 54
Ambient temperature
-20°C to +60°C; -4 °F to 140 °F
Dimensions
3.35 x 3.66 x 4.53 in (85 x 93 x 115 mm)
Cable
6.56 yards (2m) Cu-cable, ferrules, UV rated
Max. cable length (distance: Sensor
Card/Box – sensor)
Fronius Art. Nr.
100 ft (30m)
42,0411,0027