DIGIHEAT IN LINE HEATERS
Installation and
operation manual for
Single & Three Phase Models
OFFICES - AUSTRALIA
NSW - Sydney
(HEAD OFFICE)
Tel : +61 2 9898 8686
VIC/ TAS - Melbourne
Tel : +61 3 9764 1211
WA - Perth
Tel : +61 8 9273 1900
QLD - Brisbane
Tel : +61 7 3299 9900
SA/ NT - Adelaide
Tel : +61 8 8244 6000
ACT Distributor
Tel : +61 2 6280 6476
OFFICES - OVERSEAS
Waterco USA
Augusta, USA
Tel : +1 706 793 7291
Waterco Canada
St-Hyacinthe, QC, Canada
Tel : +1 450 796 1421
Waterco (Europe) Limited
Sittingbourne, Kent. UK
Tel : +44(0) 1795 521 733
Waterco (NZ) Limited
Auckland, New Zealand
Tel : +64 9 525 7570
Waterco Limited ABN 62 002 070 733
(ZZM1397) 04/2011
DigiHeat 2.4kW - 10A
DigiHeat 3.6kW - 15A
DigiHeat 4.8kW - 20A
DigiHeat 6.0kW - 25A
DigiHeat 18kW - 25A/Phase
DigiHeat 24kW - 35A/Phase
Waterco (C) Limited
Guangzhou, China
Tel : +8620 3222 2180
Waterco (Far East) Sdn. Bhd.
Selangor, Malaysia
Tel : +60 3 6145 6000
PT Waterco Indonesia
Jakarta, Indonesia
Tel : +62 21 4585 1481
Waterco International Pte Ltd
Singapore
Tel : +65 6344 2378
! WARNING
This equipment must be installed and serviced by a qualified technician.
Improper installation may result in property damage, serious injury or death.
Improper installation and/or operation will void the warranty.
Notice to Installer
This manual contains important information about the installation, operation
and safe use of this product. Once the product has been installed this manual
must be given to the owner / operator of this equipment.
www.waterco.com
Waterco Digiheat In Line Heaters I pg 01
Table of
SAFETY INFORMATION
• The electrical wiring must be permanently hardwired by Qualified Electrician in accordance with
all local wiring rules.
SAFETY INFORMATION ----------------------------------------------01
• A residual current device (RCD) having a rated residual operating not exceeding 30 mA should be
fitted to this appliance.
ELECTRICAL & WIRING ----------------------------------------------02
• The DigiHeat unit has live wiring within the unit and must not be accessible to a person within
the spa or pool. Remote temperature controllers with low voltage not exceeding 12 V may be
positioned near the spa or pool.
HYDRAULICS & REQUIRED FLOW RATES -------------------------03
• The DigiHeat must be correctly earthed.
ADJUSTING THE PRESSURE SWITCH -----------------------------03
• The installation should be carried out in accordance to local safety standards and bylaws.
INSTALLATION --------------------------------------------------------04
• The user should ensure the installation has been carried out by a suitably qualified person and
that these instructions have been carefully read and followed. Incorrectly installed equipment
may fail, causing severe injury, death or property damage
IMPORTANCE OF WATER CHEMISTRY ----------------------------01
THE TOUCHPAD -----------------------------------------------------05
OPERATING THE DigiHeat -------------------------------------------06
TEMPERATURE CALIBRATION (bias) -------------------------------07
LOSS OF POWER ----------------------------------------------------07
EMPTYING THE SPA -------------------------------------------------07
• This appliance is not intended for use by persons with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge; unless they are under supervision or instruction
concerning the use of the appliance by a person responsible for their safety.
• To prevent the risk of injury or death do not permit children to use this appliance.
TROUBLESHOOTING ------------------------------------------------08
• Do not allow anyone to sit in the spa or pool if the water temperature is greater than 38°C/ 100°F
(normal body temperature). Hyperthermia may result.
SPECIFICATIONS -----------------------------------------------------09
• In the interests of personal health, it is advised persons should not to stay in the spa for more
than twenty (20) minutes at a time.
WARRANTY -----------------------------------------------------------09
• In the event of defective operation or fault please ensure that the unit is turned off from the power
mains and contact your nearest authorised service agent.
• Ensure ALL valves are open before turning ON power to the pump and the Digiheat.
IMPORTANCE OF WATER CHEMISTRY
The DigiHeat has been carefully designed to withstand the harsh environment of a spa system,
and non metallic materials are used extensively. Where metals parts are used however such as
heater elements it is important that the water is chemically balanced to ensure that the water is
not corrosive or scale forming. Waterco will not be responsible for damage caused be corrosion or
scaling.
The chemical balance of water is a relationship between its pH, total alkalinity, calcium hardness
and temperature. Your professional pool or spa shop can test the water to ensure it is chemically
balanced in accordance with the Langelier Saturation Index. The water must be maintained at all times as per the following:
pH level : between 7.2 & 7.8.
total alkalinity : between 80 & 150ppm.
calcium hardness
: between 150 & 300ppm.
And within these tolerances to be balanced to the Langelier Saturation Index within a range of :
-0.2 to +0.2
Waterco Digiheat In Line Heaters I pg 03
ELECTRICAL & WIRING
!
HYDRAULICS & REQUIRED FLOW RATES
This equipment must be installed and serviced by a qualified technician.
Improper installation may result in property damage, serious injury or death.
Improper installation and/or operation will void the warranty.
1. The electrical wiring must be permanently hardwired by qualified electrician in accordance with
all the local wiring rules.
2. The appliance shall be supplied through a residual current device (RCD) having a rated residual
operating current not exceeding 30mA.
3. The DigiHeat must be installed within an area not accessible by any water or persons from within
the spa or pool.
4. The External Earth Bonding point is available for connection to alleviate cathodolitic corrosion of
the element.
5. A properly rated isolating switch must be connected from the supply to the DigiHeat with a
minimum rated power circuit as specified on the table below.
6. Parts incorporating electrical components except remote control device must be located or fixed
so that they cannot fall into the spa or pool.
This equipment must be installed and serviced by a qualified technician.
Improper installation may result in property damage, serious injury or death.
Improper installation and/or operation will void the warranty.
!
• Water must flow from left to right (when facing the DigiHeat).
There are arrows marked on the housing to assist in
determining the correct direction.
• The DigiHeat should be positioned upstream from any
chemical dosing or chlorinator and a check valve should be
installed to prevent corrosive water from flowing back into the
DigiHeat.
• In the event of DigiHeat being installed more than 1.8m below the pool water level the
adjustable pressure switch will not work. A flow switch must be installed in place of the pressure
switch.
• Required flow rates table
7. To access and carry out the electrical connections the front cover with the digital controller needs
to be removed. The front cover of the DigiHeat is hinged from the bottom to make it easier to
remove and replace it.
To remove the front cover :
i) remove the 6 spring loaded quarter turn locking pins first
ii) pull the cover gently from the top
DigiHeat Model
Minimum Flow Rate
Maximum Flow Rate
2.4 kW
3.6 kW
4.8 kW
6.0 kW
18.0 kW
24.0 kW
100
100
100
100
150
150
350
350
350
350
450
450
(litres per minute)
(litres per minute)
iii) now slide the cover across to the left to disconnect the hinges.
Reverse the procedure above to ensure the cover is replaced correctly when all work is completed.
DigiHeat Model
Volts
Current Draw Minimum Circuit size
2.4 kW
240 Volts (single phase)
10 A
15 A
3.6 kW
240 Volts (single phase)
15 A
10 A
4.8 kW
240 Volts (single phase)
20 A
10 A
6.0 kW
240 Volts (single phase)
25 A
10 A
18.0 kW
415 Volts (single phase)
25 A/phase
30 A/phase
24.0 kW
415 Volts (single phase)
35 A/phase
30 A/phase
HYDRAULICS & REQUIRED FLOW RATES
!
This equipment must be installed and serviced by a qualified technician.
Improper installation may result in property damage, serious injury or death.
Improper installation and/or operation will void the warranty.
To adjust the pressure switch:
• Switch OFF the power to the DigiHeat.
• Remove front cover of DigiHeat.
• Ensure the filter is clean & run the pump with the filtration system as normal (FILTER MODE) until
all the air has been bled from the system.
• Turn the pump OFF and check that the pressure switch turns OFF immediately or after a short
delay (1 to 2 secs). If it is not possible to hear the pressure switch operate, connect an Ohmmeter
across the Pressure Switch terminals.
• If the pressure switch remains ON after the pump stops, increase the operating pressure by
turning the small adjusting screw slowly clockwise until the switch turns OFF.
DigiHeat Single Phase
DigiHeat 3 Phase
Waterco Digiheat In Line Heaters I pg 05
THE TOUCH PAD
• If the adjustment required is outside the
range of this switch then a different switch
or a flow switch will be needed to protect the
heater.
• Stop and start the pump several times
to check the correct operation. Repeat if
necessary.
• Replace front cover on DigiHeat.
pressure switch adjustment screw
1. Digital display. Displays the water temperature, bias setting and fault codes.
2. On/Off button. Used to switch the Digiheat On or Off.
3. Up arrow button.
Used to increase the desired water temperature and also increase the
bias setting. (refer to bias adjustment section.)
4. Down arrow button. Used to decrease the desired water temperature and also decrease
the bias setting. (refer to bias adjustment section.)
5. ˚C/ ˚F button. Use to toggle between Farenheit and Celcius.
6. ˚C indicator light. temperature displayed in ˚C
7. ˚F indicator light. temperature displayed in ˚F
INSTALLATION
DigiHeat single phase models can be mounted directly onto the pipework, fixed to a wall or base
mounted. Wall and base fittings are supplied.
3
5
Digiheat three phase units can be mounted directly onto the pipework or fixed to a wall.
Wall fittings are supplied with the unit.
1
Direct mounting onto pipework
- simply connect the Digiheat to the pipework. Ensure
the pipework is rigid and secure.
wall mounting
- use the 4 small mounting brackets supplied.
Slide two small mounting brackets into the channel
located on the top of the Digiheat and the same on the
bottom.
small mounting brackets
6
2
7
4
Digiheat Touch-Pad
base mounting
– use the 2 large mounting brackets supplied
(single phase model only).
Slide two large mounting brackets into the channel
located on the bottom of the DigiHeat
large mounting brackets
Waterco Digiheat In Line Heaters I pg 07
OPERATING THE DIGIHEAT
TEMPERATURE CALIBRATION (bias)
After familiarising yourself with the layout and settings of the touch pad (see previous section), fill the
spa or pool with water and follow the instructions below.
It is possible to have a temperature variation between the water in the spa or pool and the DigiHeat
controller. This is also referred to as the “Bias” adjustment setting. This adjustment can only be
carried out whilst the controller is set for “C” (centigrade).
We suggest that you instruct all the people who will use the spa or pool fitted with the DigiHeat on
how to operate it by either by giving them this manual or by showing them yourself.
Example: if the water in the pool or spa is 26º C and the DigiHeat control displays 24ºC.
Reading, understanding and following this guide should lead to trouble free operation of the DigiHeat
spa and pool heater.
To calibrate the temperature variation, set the bias to +2 with the following procedure:
1. Fill the spa or pool with water and then switch on the water pump.
2. With the use of an accurate thermometer read the pool or spa water temperature (e.g.: 26˚C).
2.Switch on the power to the DigiHeat. The controller will then display “OFF” or the water
temperature. If the pump is not running or if there is insufficient water flow, “nFL” will be displayed.
(Please refer to troubleshooting section of this manual for “nFL”)
3. If the display reads “OFF” press the on/off button to switch on the Digiheat, the temperature will
then be displayed.
4. Press and release the Up or Down button and the set temperature will be displayed with either
the ˚C or oF indicator LED flashing.
• To increase the desired set temperature press and hold the up button which will allow the
set temperature to be raised up to a maximum of 40˚C (104˚F). Release the button when the
desired temperature is displayed on the screen.
• To decrease the desired water temperature press and hold the down button. Release the
button when the desired temperature is displayed on the screen.
1. Switch on both the pump and the Digiheat.
3. Next read the temperature displayed on the DigiHeat control (eg: 24˚C).
4. To determine the bias setting subtract the pool or spa water temperature from the DigiHeat
Temperature.
Eg : 26 - 24 = 2˚C. Therefore we must compensate for the variation by setting the bias to +2.
If the temperatures were reversed eg; the water temperature was 24 and the Digiheat control was
26 we would require a bias setting of -2.
Eg : 24 - 26 = -2. Therefore we must compensate for the variation by setting the bias to -2.
5. Enter the programming mode by simultaneously pressing on the UP and DOWN arrows.
6. Once the temperature display is flashing press on the ON/OFF button.
7. Using the UP and DOWN arrows, enter the calibration value, (+2). In this case, by pressing the UP
arrow twice.(if the down arrow is used the bias will be a negative figure)
8. Once the bias has been entered wait until the calibrated temperature appears back on the display.
5. With an accurate thermometer check that the actual water temperarture in the pool or spa is the
same as the temperature displayed on the Digiheat.
If the displayed water temperature is different to the actual water temperature the controller will need
to be calibrated. This can only be done whilst the temperature is shown in ˚C. Refer to the following
section “temperature calibration”.
LOSS OF POWER
If the power supply to the Digiheat is lost, either by disconnecting it from the power supply or from
a “blackout”, when power is restored the DigiHeat will operate as follows,
1. If the Digiheat was “ON” prior to the power interruption, it will continue heating if the pump is
running and the set temperature is higher than the displayed temperature when the power is
restored. If the pump is not running the display will show nFL.
2. If the Digiheat was switched “OFF” prior to the power interruption, it will remain “OFF” when
power is restored.
EMPTYING THE SPA
If you intend emptying the water from the spa, disconnect the Digiheat and pump from the power
supply (isolating switch) to ensure the Digiheat will not be accidentally switched on while the spa is
empty. The pump can be damaged if it is run without water. Serious damage or injury may result.
Waterco Digiheat In Line Heaters I pg 09
TROUBLESHOOTING
Specifications
The spa pump should only be serviced by qualified service technicians. However, some problems
can be checked and rectified by the owner before making a service call. FAULT
Display is blank
nFL
o/t
POSSIBLE CAUSE
No power
Check the isolating switch is on and not
damaged.
Blown fuse
Check the power circuit fuse or circuit breaker
has not blown or tripped.
RCD tripped
Reset RCD.
Pump not on or pressure switch
needs to be adjusted
Switch on pump or adjust pressure switch.
Over-Temperature Reset Switch
tripped
See “Over-Tempture Resure Reset Switch
tripped” below.
Water inside Digiheat reached
45°C /113°F (spa water is still cold)
Over-Temperature
Reset Switch tripped
(touch pad power
indicator light
blinking)
ACTION
Water in spa reached
45°C /113°F
(touch pad shows lower
temperature)
Over-Temperature Sensor not
connected or faulty
Model
Weight Min
(kg)
Flow
Rate
(lpm)
2.4 kW
3.5
100
3.6 kW
3.5
100
4.8 kW
3.5
100
6.0 kW
3.5
100
18.0 kW
9.5
150
24.0 kW
9.5
150
Complies with EN60335.2.60 and AS3136/NZS6232.
312
Check for and remove blockages in the filter and
pipe-work. Check for blockages in the impeller
and call for service if items are found in the
pump/impeller. Press Over-Temperature RESET.
332
Properly secure sensor in housing (refer to
“Installing the Sensor” on page Press OverTemperature RESET.
Touch pad display
shows 00
Heater will not
operate
Over temperature Sensor not
connected.
240
Check sensor is connected to Control Box.
If not, call service to connect the sensor.
Temperature Sensor faulty.
Call for service to replace Temperature Sensor.
Water level too low
Add water to spa or pool to operate pressure
switch.
Faulty element
161
469
Re check Temperature Bias
(refer to “temperature calibration”)
Press Over-Temperature RESET.
Call service to connect or replace.
Over-Temperature
Reset Switch tripped
shortly after powerup
Max Supply frequency
amps
minimum
IP
Max
Flow Voltage
(Hz)
circuit rating Pressure
Rate (volts)
size
(kpa) @
(lpm)
(amps)
31m head
350
240
50
10
15
IP23
300
350
240
50
15
20
IP23
300
350
240
50
20
25
IP23
300
350
240
50
25
30
IP23
300
450
415
50
25 /phase
30
IP23
300
450
415
50
35 /phase
40
IP23
300
161
273
594
267
Call for service.
736
WARRANTY
Waterco DigiHeats are covered by a comprehensive 12 month warranty.
Please refer to Waterco’s warranty terms and conditions.