Enclosed Direct-On-Line Reversing and Non-Reversing Starters, A-B 105-C and 109

Enclosed Direct-On-Line Reversing and Non-Reversing Starters, A-B 105-C and 109
EC Declaration of Conformity
The undersigned, representing the manufacturer
Rockwell Automation
Buchserstr. 7
CH-5000 Aarau
Switzerland
and the authorised representative established within the
Community
Rockwell Automation BV
Rivium Promenade 160
2909 LM Capelle aan den IJssel
The Netherlands
herewith declare that the Products:
Enclosed Direct-On-Line Reversing and Non-Reversing
Starters
Product identification (brand and
catalogue number/part number):
Allen-Bradley 105-C and 109-C Series
(reference the attached list of catalogue numbers)
are in conformity with the essential requirements of the following EC Directive(s) when installed in accordance with
the installation instructions contained in the product documentation:
2006/95/EC
Low Voltage Directive
2004/108/EC
EMC Directive
and that the standards and/or technical specifications referenced below have been applied:
EN 60947-1:2007
Low-voltage switchgear and controlgear – Part 1: General rules
EN 60947-4-1:2001 + A1:2002
+A2:2005
Low-voltage switchgear and controlgear – Part 4-1: Contactors and motorstarters – Electromechanical contactors and motor-starters
EN 60947-5-1:2004 + A1:2009
Low-voltage switchgear and controlgear – Part 5-1: Control circuit devices
and switching elements – Electromechanical control circuit devices
EN 62208:2003
Empty enclosures for low-voltage switchgear and controlgear assemblies –
General requirements
Year of CE Marking (Low Voltage Directive):
2011
Manufacturer:
Authorised Representative in the Community:
Signature
Name:
Position:
Date:
Signature
Name:
Position:
Date:
Daniel L. Nachtigall
Supv – Product Certification Engineering
30-Apr-2012
Document Control Number: PCC-0388-B-EN
Viktor Schiffer
Engineering Manager
10-May-2012
1/2
Enclosed Direct-On-Line Reversing and Non-Reversing Starter
Catalogue Number Explanation
105 – C
109 – C
1
Position
Catalogue No. Suffix
1
105 – C
109 – C
2
09
12
16
23
30
37
43
3
4
V
K
L
One or two letters
5
E1C
E1D
E1E
E1F
6
No suffix
1
1M
7


2


3


4


5
-


6
Options/Descriptions
Base Catalogue Number of DOL Reversing Starters
Base Catalogue Number of DOL Non-reversing Starters
Contactor Code
100-C09 contactor
100-C12 contactor
100-C16 contactor
100-C23 contactor
100-C30 contactor
100-C37 contactor
100-C43 contactor
Enclosure Type
198E-A0S4 enclosure, ABS, IP66
198E-C0S4 enclosure, PC, IP66
198E-C2S4 enclosure, PC, IP66
Coil code (Indicates coil – voltage and – frequency)
AC coil code (conventional coil: 12...550V50 Hz)
AC coil code (conventional coil: 12...600V60 Hz)
AC coil code (conventional coil: 24...440V50/60Hz, double frequency)
Electronically controlled DC coil code: 24VDC
Overload Relay Code
193-E1C overload relay, 1.0…5.0 A
193-E1D overload relay, 3.2…16 A
193-E1E overload relay, 5.4…27 A
193-E1F overload relay, 9.0…45 A
Option Codes
No options
Start/Stop pushbuttons
Start/Stop multifunction pushbutton
Reset pushbutton
Document Control Number: PCC-0388-B-EN