Power Modules
These Versatile Rectifier Modules function as either power supplies or battery chargers for 12, 24 or 48 volt systems; positive,
negative or floating ground. They may be employed singly or in combination, enabling the installer to scale the system anywhere
from 500 to 10,000 watts per rack. Units may be paralleled for N + 1 redundancy and alarm contacts allow local or remote
monitoring. An optional DC quick connect wiring kit allows easy replacement of modules without system shutdown.
Power Modules may be used separately as a power
source, or they may be integrated with
the Power Function Manager
(see opposite page) to
greatly expand the
system capability with
other functions such as
digital output monitoring,
powering multiple loads
via circuit breaker
distribution and low
voltage battery disconnect.
Features
•
•
•
•
•
•
12, 24 or 48 volts output; pos., neg. or floating ground
115 or 230 VAC, 50-60 Hz input 560 & 1000 watt models
230 VAC only 2200 watt model
560, 1000 or 2200 watts per module (approx.)
Built-in oring diode for parallel or N + 1 configuration
Power supply or battery charger operation (DC UPS system)
Protection
Case Size
Centimeters
13.5 43.2 52.1
H
D
W
*19” and 23” mounting brackets provided
H
4
Newport Beach, CA W
USA
D
Output
@ Full Load
VDC
VDC
Amps
115/230V
V Out
V2
Cont.+
PM-12-40
8.5/4.3
13.6
14.3
PM-12-70
16/8
13.6
14.3
PM-24-20
8.5/4.3
27.2
PM-24-35
16/8
PM-48-10
8.5/4.3
PM-48-18
PM-48-50
Model
Mechanical/General
Inches
H
W* D 3.5
17
20.5
Battery charging options: three-step charging, gel/lead-acid switch, equalization and temperature compensation
Remote shutdown control option via TTL signal (except 2200 watt models)
Form C alarm contacts
19" or 23", 2 RU, flush or 6” forward rackmount
Input Amps
• Output fuse for reverse polarity
• Current limit
• Input circuit breaker
• Automatic high temp. output power reduction
• Forced air cooling with filter provided
• Anodized aluminum front panel
•Vinyl laminated base and cover
•19" or 23" Rackmount, brackets provided
• Wallmount via optional brackets
•IEC AC entry module. 6’ power cord with NEMA 5-15 plug, 115 VAC.
(560 watt models)
•6’ power cord with NEMA 6-15 plug, 230 VAC (1,000 watt models)
• 6’ power cord with NEMA 5-20 plug, 115
VAC also supplied (1,000 watt models)
• Hardwire junction box on 2200 watt units, no power cord provided
•1/4” -20 Output stud (560 watt models)
•Output bus bar (1,000 & 2200 watt models) with 1/4” - 20 studs
•Output "OK" L.E.D.
•Loss-of-output alarm contacts- Form C, plus loss of AC alarm contacts Form C
(2200 watt units only)
•Front panel voltage test points
•
•
•
•
Weight
Watts
Lbs
Kg.
40
560
12.2
5.5
70
1000
15.2
6.9
27.9
20
560
12.2
5.5
27.2
27.9
35
1000
15.2
6.9
54.4
55.1
10
560
12.2
5.5
16/8
54.4
55.1
18
1000
14.0
6.4
*/22
54.4
—
50
2200
34
15
VDC (V out) Measured at output terminal with oring diode
* 230 VAC input only
VDC (V2) Measured at direct output terminal
+ For parallel configuration/load sharing derate output 10%
Performance Specifications
Options
Design Standards
Temperature Rating
•
•
•
•
•
•
•
Input: 85-135/170-270 VAC (selectable), 47-63 Hz. 560 & 1000 watt models.
207-253 VAC only 2200 watt models
Power Factor: 0.7
Regulation: ± 1% at direct output (V2);
± 2% through "oring" diode (V out)
Ripple: 1% (Typical)
Efficiency: 80-85% @ full load
Front panel Output Voltage adjustment pot range: ±10%
Altitude Range: Full output to 5,000 feet.
Derate output current 4% per 1,000 feet to 10,000 feet max.
• UL 1950 / EN 60950 (Safety)
• EN 50082 (Immunity)
• EN 55014 (Conducted)
•
•
•
•
•
* 230 VAC input only
Three stage charger function with
gel/lead-acid selector Model: CFB
560 & 1000 watt units only
Temperature compensation (for battery charging). All models.
DC quick connect wiring kit, 560 & 1000 watt Models: QCK-3 (for 2-3 unit PM system), QCK-6 (for 4-6 unit PM system), CCK-4 (2200 watt models)
“Universal” mounting bracket; Model: UMB-PM (500 & 1KW models only)
Metering, alarms, LVD and distribution breakers (PFM-400 option)
560 & 1000 watt models: -40° C to +60° C;
Derate linearly from 100% load @ 50°C to
75% @ 60° C
2200 watt models: 0-50°C
Powering the Network