SELECTRONIC PROGRAMMING Innsbrook™

SELECTRONIC PROGRAMMING  Innsbrook™
SELECTRONIC
Innsbrook™
0.5 GPF urinal
PRODUCT NUMBER
A922265-0070A
10’ CONNECTION
CABLE
6520. Series
A950489-0070A
MULTI BOARD
738807-0070A
MULTI BOARD
CASE ASSEMBLY
M950169-0070A
PLUG-IN
POWER SUPPLY
738715-1000A
KIT 240
ELECTRONIC/SENSOR
ASSEMBLY
738708-0070A
BATTERY CASE
738233-XXXOA
COVER MOUNTING KIT
738709-0070A
PHOTO LITHIUM BATTERY
738232-XXXOA
URINAL COVER WITH
COVER MOUNTING KIT
A950508-0070A
STRAINER
47058-0070A
K-2 HANGERS
M962389-0070A
SOLENOID
A950510-0070A
SUPPLY STOP
47082-0070A
OUTLET
CONNECTION
A950503-0070A
MANIFOLD ASSEMBLY
738784-0070A
RUBBER GROMMET
738786-0070A
FLEX HOSE
738785-0070A
1/4 TURN SHUTOFF VALVE
738781-0070A
BACKFLOW PREVENTER
Replace the "XXX" with
appropriate finish code
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
1 (800) 442-1902
Weekdays 8:00 a.m. to 8:00 p.m. EST
WHITE
BONE
SILVER
LINEN
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
IN MEXICO 01-800-839-12-00
Product names listed herein are trademarks of American Standard Inc.
© American Standard Inc. 2006
8
020
021
165
222
PROGRAMMING
Connect the sensor to the battery / power supply. The sensor L.E.D. will flash for
5 seconds. After 5 seconds, the sensor will be ready for use.
Turn water supply back on and test the installation. Stand infront of the sensor for
at least 5 seconds then move away. Urinal should flush for the preset duration of
6 seconds.
If the urinal functions properly and the detection zone and duration is adequate,
run the wire through the slot on the Battery Pack housing and close Battery Pack
cover. It is recommended to use a sealant in the wire-through slot on the Battery
Pack housing. It is recommended to use a non-permanent sealant only (like
plumber’s putty) around the Battery Pack Cover and around the cover screw
slots. Tie up any excess wire for a “cleaner” installation and re-attach ceramic
cover (with washer/cap) using the special screw and screwdriver.
If there is a problem with the flush or the detection zone or the flush time needs
to be adjusted, disconnect the sensor from the battery / power supply and
proceed as listed below.
NOTE: Please read all the instructions prior to attempting to program the
sensor.
The Detection Zone (distance) and the Flush Time Settings can be easily
changed without a remote control device. The programming mode is activated for 5
seconds each time the power is connected to the sensor. If programming is required,
after the sensor has been in operation, the power (battery or mains) source must
first be disconnected. Start with the power disconnected from the sensor.
Setting the Detection Zone (Distance): Apply power to the sensor. While the
Sensor Control LED is blinking slowly, place your hand 30 –50 mm (1 – 2 in.) in
front of the sensor. When the LED stops blinking and stays “on,” stand just
beyond the desired detection distance (in line with the sensor). Stay at that
position until the LED begins to blink again. If the flush time also needs to be
changed, follow the next steps for “Setting the Time Period” as described below.
Setting the Time Period: Immediately after setting the distance while the LED is
blinking, again hold your hand in front of the sensor (distance about 30-50mm (1-2in.)).
The Sensor Control LED will turn off and then begin to flash very slowly (approximately
every 2 seconds). Each flash represents a time period value. - See below for time
period table. When the sensor has flashed the number of times correlating to the
desired time period, remove your hand from the detection zone of the sensor.
TIME PERIOD TAB LE
Urinal Function
Flash Number
Flush Time
1
2
3
4
4 sec
6 sec
8 sec
10 sec
9
TROUBLE SHOOTING GUIDE
1. CHECK POWER SUPPLY FIRST! Various problems can be caused by low dc supply voltage.
(a) Operating range is 5.4 to 6.4 volts.
(b) On units which contain a 6 volt battery pack, be sure that holder contains 1 Lithium Photocell Battery,
that battery contacts are not corroded, and electrical connections are secure. Battery replacement is
required if voltage is less than 5.4 volts.
(c) On units that use an external 6 volt dc supply, check that 6 volts dc supply voltage is present, and that
electrical connections are secure.
(d) Continuous double flashing indicates low battery.
2. DO PREVENTATIVE MAINTENCE:
Check that sensor area is clean. If needed, clean with soft cloth dampened with warm water or non-abrasive
glass cleaner.
3. TO ACTIVATE FLUSH CYCLE:
Stand to side of unit an place hand in front of IR sensor for 5 - 7 seconds, remove hand to activate flush cycle.
LISTEN for ON and OFF “clicks” from water control solenoid that control flush cycle.
CHECK IF VOLTAGE
IS GREATER THAN
5.4 VOLTS
NO FLUSH
NO
CHECK CONNECTIONS
OR
REPLACE BATTERIES
YES
IS SUPPLY
VALVE
FULLY OPEN?
NO
OPEN VALVE
YES
IS FILTER
CLOGGED?
YES
REPLACE OR CLEAN
FILTER
NO
YES
OK
CAN FLUSH
CYCLE BE
ACTIVATED NOW?
NO
ACTIVATE
FLUSH
CYCLE
DOES WATER
CONTROL SOLENOID
“CLICK” ON/OFF
REPLACE /REBUILD
WATER CONTROL
SOLENOID
NO
FLUSHES
CONSTANTLY
REPLACE SENSOR
MODULE
REPLACE/REBUILD
WATER CONTROL
SOLENOID
10
AMERICAN-STANDARD ONE-YEAR LIMITED WARRANTY
If inspection of this American-Standard plumbing product, within one year after its initial purchase, confirms that it is defective
in materials or workmanship, American-Standard will repair or, at its option, exchange the product for a similar model.
This warranty does not apply to local building code compliance. Since local building codes vary considerably, the purchaser
of this product should check with a local building or plumbing contractor to insure local code compliance before installation.
This warranty shall be void if the product has been moved from its initial place of installation; if it has been subjected to faulty
maintenance, abuse, misuse, accident or other damage; if it was not installed in accordance with American-Standard's
instructions; or if it has been modified in a manner inconsistent with the product as shipped by American-Standard.
American-Standard's option to repair or exchange the product under this warranty does not cover any labor or other costs of
removal or installation, nor shall American-Standard be responsible for any other incidental or consequential damages
attributable to a product defect or to the repair or exchange of a defective product, all of which are expressly excluded
from this warranty. (Some states or provinces do not allow the exclusion or limitation of implied warranties, so this exclusion
may not apply to you.)
This warranty gives you specific legal rights. You may have other statutory rights that vary from state to state or from province
to province, in which case this warranty does not affect such statutory rights.
For service under this warranty, it is suggested that a claim be made through the contractor or dealer from or through whom the
product was purchased, or that a service request (including a description of the product model and of the defect) be sent to the
following address:
In the United States:
American Standard Inc.,
P.O. Box 6820
Piscataway, New Jersey 08855
Attention: Director of Consumer Affairs
In Canada:
American-Standard,
2480 Stanfield Rd.,
Mississauga, Ontario
Canada L4Y 1S2
For residents of the United States, warranty
information may also be obtained by calling the
following toll free number: (800) 442-1902
Toll Free: (800) 387-0369
730795-100 Rev.D
11
In Mexico:
Customer Service Manager
Ideal Standard, S.A. de C.V.
Via Morelos #330
Col. Santa Clara
Ecatepec 55540 Edo. Mexico