7c ” VICON INSTRUCTIONS FOR INSTALLATION AND OPERATION

7c ” VICON INSTRUCTIONS FOR INSTALLATION AND OPERATION
SHEET
NOTES
” VICON
7c
X410
REV. ! SEC.
695
12
I
INSTRUCTIONS FOR
INSTALLATION AND OPERATION
MODEL VISLPG GROUNDED SURGE PROTECTOR
The VlSLpG Grounded Surge Protector provides protection to sensitive video equipment from power line
surges. The peak pulse power dissipation is 1500 W at
77’ F (25’ C) at 1 ms, and the response time from 0 V
to clamping is less than 5 nanoseconds.
The VlSLPG should be ihstalkd at the control-center
end of the video cable run. For example, if several
cameras are connected to a switcher, the surge protector
should be installed at the switcher end of the cable run.
Refer to Figure 1.
The VlSLPG is provided with one male and one female
BNC connector and a screw terminal clamp for the
ground. To install the protector, insert it in the video
line at the protected equipment and connect a ground
line from the screw clamp to a known good ground.
EARTH GROUND SCREW
Figure 1
V15LPG Installation Diagram
WARNING: TO PREVENT RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS UNIT TO RAIN OR MOISTURE.
Product specifications subject to change without notice.
Copyight 63 1995 Vice Industries Inc. All rights reserved.
Vicm part number 8006-8410-00-00
Vicon and its logo are registered trademarks of Vicon Industries Inc.
VICON INDUSTRIES INC. 525 BROAD HOLLOW ROAD, MELVILLE, N.Y. 11747 TEL: 516-293-2200 FAX: 516-293-2627
TOLL FREE: l-800-645-91 16 UK: 44/(O) 1489/577775 INFOFAX: 1-800-287-l 207
Shipping Instructions
Use the following procedure when returning a unit to
the factory:
1.
2.
Call or write Vicon for a Return Authorization
&A.) at one of the locations listed below. Record the name of the Vicon employee who issued
the R.A.
VICON INDUSTRIES INC.
525 Broad Hollow Rd.
Melville, NY 11747
516-293-2200 l-800-645-9116
For service or returns from countries in Europe,
contact
Attach a sheet of paper to the unit with the
following information:
a.
Name and address of the company returning
the unit
b.
Name of the Vicon employee who issued the
R.A.
C.
R.A. number
d.
Brief description of the installation
e.
Complete description of the problem and
circumstances under which it occurs
f.
Unit’s original date of purchase, if still under
WiUEUlty
VICON INDUSTRIES (U.K.) LTD
Brunel Way
Fareham, PO15 5TX
United Kingdom
44/(O) 1489/577775 Fax: 44/(O) 1489/578923
3.
Pack the unit carefully. Use the original shipping
carton or its equivalent for maximum protection.
4.
Mark the R.A. number on the outside of the
carton on the shipping label.
X410-695
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising