L2 L3 L1 T1 T2 T3
460-60-3
POWER SOURCE
11
52
51
4
5 PIN PLUG
FOR INDOOR
BLOWER MOTOR
5
L1 L2 L3
L1
L2
L3
4
Ground
Fuse
Fuse
19
T1
L2
T2
L3
T3
3
L2
L3
Compressor
10
YELLOW
53
39
4 5
BLACK/WHITE
6
GREEN
38
RED/WHITE
54
R
460V
BLACK/WHITE
55
C
COM
31
RED
15
Transformer
BLACK
45
10
RED
12 11 10 9 8 7 6 5 4 3 2 1
12 PIN
VENT PLUG
FOR ANTIFREEZE LOOP APPLICATIONS, CONNECT THE
1 LOW PRESSURE SWITCH WITH YELLOW LEADS IN PLACE
OF THE LOW PRESSURE SWITCH WITH BLUE LEADS. ONE
LEAD WILL CONNECT TO BROWN LEAD FROM THE FLOW
SWITCH, AND THE OTHER WILL CONNECT TO THE YELLOW
LEAD COMING FROM THE LPC TERMINAL OF THE
COMPRESSOR CONTROL MODULE.
REMOVE WIRE FROM TERMINAL
2 Y2 AND TAPE OFF WHEN LOWER
FULL LOAD CFM DESIRED
NO ERV
3.2
3.2
3.2
5
27
High Speed
Solenoid
BLACK/WHITE
PURPLE
48
Reversing
Valve
Three way
Valve
BLUE/WHITE
BLUE/BLACK
RED
L2
53
L1
35
20
35
1
3
2
G
6
9
12 PIN
VENT PLUG
27
3
5
4
6
2
A2 G1 Yo
A1 G Y
1
7
8
9
C
R C
12 LOW
VOLTAGE
STRIP
10
11
12
2
1 3
4
5 6
7
8 9 10 11 12
1
2 3
!
Step Down
Transformer
Low Pressure
Control
Wire Identification numbers
for Bard use only.
Compressor
6
DANGER
! WARNING
USE COPPER CONDUCTORS
ONLY SUITABLE FOR AT LEAST
75° C.
Factory Field Optional
BLUE
Flow Switch
Low Pressure
Control
5
*ELECTRICAL SHOCK HAZARD
*DISCONNECT POWER BEFORE
SERVICING.
99
YELLOW
4
6 PIN 27
CO2 PLUG
1
Hi Pressure
Control
14 DEHUM
RELAY
W
R
D
BLACK
L3
7
O
DEHUM
LOGIC
58
36
4
Y1
1
39
A
Y2
FREEZE
T-STAT
4 5
A
10 12 PIN PLUG FOR
THERMOSTAT
BLUE
STEPDOWN
TRANSFORMER
CLASS CC FUSE
C
1 2 3
BLUE
BLACK/WHITE
Y
OPTIONAL 3 PIN
PLUG FOR ERV
BLUE
27
BLACK/WHITE
460 VOLT PACKAGE
UNIT DIAGRAM
45
24
E
TWV
BLACK/
WHITE
27
18
BLACK/WHITE
39
Check Light
ALR
19
BLACK
32
R
LPC LPC
39
Compressor
Contactor
Fuse Block
6 PIN
CO2 PLUG 27
38
38
BROWN
ORANGE
T1 T2 T3
CC
YELLOW
3
YELLOW
HPC
B
L
Comp.
Control
Module
24
YELLOW/RED
RED
2
BLACK/WHITE
48
27
LPC
THREE WAY VALVE
YELLOW
BLUE/BLACK
2 12 3 1
BLACK
BLACK
1
RED/WHITE
C
Compressor
Control Module
REVERSING VALVE
37
L1 L2 L3
RED/
WHITE
38
ALR
LPC
BROWN
RED/
WHITE
42
43
BLACK
9
Y CC
R
34
BROWN
38
RED
41
BLACK
YELLOW
YELLOW
B
10
LOW
VOLTAGE
STRIP
L1 L2 L3
RED
A
10
10 13 14 15 6
HPC
PINK
44
BLUE
9
BLACK
12
C
Y
21 Phase Monitor
RED
7
RED/WHITE
W / ERV
5
5
7
7
C
Flow Switch
RED
6
RED
RED
GREEN
10
4
40
YELLOW
53
3
BLACK
10
PINK
MODEL
QW2S
QW3S
QW4S
QW5S
L3
Yo
Compressor
Contactor
Low Pressure
Switch
16 PIN PLUG FOR
INDOOR BLOWER MOTOR
10
Ground
Terminal
4
27
Yout
YELLOW/BROWN
56
1
GREEN
BLUE/BLACK
34
10
RED
DEHUM
10
RED
PURPLE
14 RELAY
BROWN
RED/WHITE
10
PINK
8 9 10 11 12
10
YELLOW
30
YELLOW
BLUE
5 Rotary Disconnect
BLACK/WHITE
57
10
BLUE
29
YELLOW
Brown
BROWN/WHITE
BLACK
46
Term.
Block
RED/WHITE
7
RED/WHITE
BLACK/WHITE
50
YELLOW
5 6
BLUE
BROWN
28
BROWN/WHITE
4
ORANGE
YELLOW
YELLOW
55
RED/YELLOW
BROWN/WHITE
L2
Y
19
High
Pressure
Switch
RED
PURPLE
2 3
RED/YELLOW
PURPLE
PURPLE
2
BROWN
1
ORANGE
54
L1
24VAC
53
PURPLE/WHITE
COM
Transformer
BLACK/WHITE
BLACK/WHITE
10
3
2
L1
460
12 PIN PLUG FOR
THERMOSTAT 10
1
230-60-1
Compressor Contactor
L1
4
Step Down
Transformer
Optional 3 Pin
Plug For ERV
11
5 Pin Plug
5 for Indoor
Blower Motor
460-60-3 POWER SOURCE
5 Circuit
Breaker
BLACK
GREEN
RED
3
BROWN
BLUE
GRAY
YELLOW
ORANGE
YELLOW
YELLOW
FREEZE
THRMOSTAT
PURPLE
DEHUM. CONTROL 49
BLACK
BLACK/WHITE
BLACK
14 12 15 3 1 10 6 9 13 2
RED/WHITE
16 PIN PLUG FOR
INDOOR BLOWER
MOTOR 10
High Voltage
Low Voltage
4113-301 D