YORK Sunline Ultra DH 036, DH 048, DH 060 Air conditioner Technical Guide
Sunline Ultra DH 036, DH 048 and DH 060 are convertible single package air conditioners with a common cabinet and a common roof curb for the 3, 4 and 5 ton sizes. The units were designed for light commercial and commercial applications. They can easily be installed on a roof curb, slab, roof jack or frame.
PDF
Download
Document
Advertisement
Advertisement
036-21506-004-A-1105 ® DESCRIPTION YORK Sunline Ultra® units are convertible single package air conditioners with a common cabinet and a common roof curb for the 3, 4 and 5 ton sizes. The units were designed for light commercial and commercial applications. They can easily be installed on a roof curb, slab, roof jack or frame. TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS All units include: • Powder Paint finish that meets ASTM-B-117 1000 hour salt spray standards AIR CONDITIONERS • Permanently lubricated motors DH 036, 048 & 060 • Bottom or side air discharge configuration capability (field convertible) • Manufactured under the quality standards of ISO9001 • SimplicityTM Control Board • Copper tube/aluminum fin coils • Easy access to all components • Rigging holes in base rails for lifting • Fork lift slots on three sides • Single point power connection • Complete factory package - tested, charged and wired • Belt Drive Indoor Blower • CSA agency listing on all units AND SINGLE PACKAGE 3, 4 & 5 NOMINAL TONS 12.2 THROUGH 13.2 SEER WARRANTY • Factory Limited Parts Warranty • One-year parts warranty • A Five-year parts warranty on the compressor and electric heat elements. • Ten-year parts warranty on the gas-fired heat exchangers. FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE 036-21506-004-A-1105 TABLE OF CONTENTS DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 PRODUCT NOMENCLATURE . . . . . . . . . . . . . . . . . 3 LIST OF TABLES Tbl. # Pg. # FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 1 SOUND POWER RATING . . . . . . . . . . . . . . . . . . . . . . 15 FACTORY-INSTALLED OPTIONS . . . . . . . . . . . . . 12 2 CAPACITY RATINGS - (ARI 210/240) . . . . . . . . . . . . 15 FIELD-INSTALLED ACCESSORIES . . . . . . . . . . . 13 3 GAS HEAT RATINGS . . . . . . . . . . . . . . . . . . . . . . . . . 15 4 2 STAGE GAS HEAT RATINGS . . . . . . . . . . . . . . . . . 15 5 DH036 COOLING CAPACITIES (3 TON) . . . . . . . . . . 16 6 DH048 COOLING CAPACITIES (4 TON) . . . . . . . . . . 17 7 DH060 COOLING CAPACITIES (5 TON) . . . . . . . . . . 18 8 SUPPLY AIR BLOWER PERFORMANCE (3 TON BELT DRIVE) - SIDE DUCT APPLICATION . . . . . . . . . . . . . 19 9 SUPPLY AIR BLOWER PERFORMANCE (4 TON BELT DRIVE) - SIDE DUCT APPLICATION . . . . . . . . . . . . . 20 GUIDE SPECIFICATIONS . . . . . . . . . . . . . . . . . . . 33 LIST OF FIGURES Fig. # Pg. # 1 UNIT CUTAWAY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 2 TYPICAL FIELD POWER & CONTROL WIRING . . . . 26 3 UNIT DIMENSIONS (3 - 5 TON COOLING ONLY/ ELECTRIC HEAT) FRONT VIEW . . . . . . . . . . . . . . . . 27 4 UNIT DIMENSIONS (3 - 5 TON COOLING/GAS HEAT) FRONT VIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 5 UNIT WITH ECONOMIZER RAINHOOD . . . . . . . . . . . 28 6 UNIT WITH FIXED OUTDOOR AIR/MOTORIZED DAMPER RAINHOOD . . . . . . . . . . . . . . . . . . . . . . . . . 28 13 ELECTRIC HEATER CFM LIMITATIONS . . . . . . . . . . 22 7 UNIT DIMENSIONS (REAR VIEW) . . . . . . . . . . . . . . . 29 14 ELECT DATA - DH036, 048 & 060 BELT DRIVE WITHOUT POWR’D CONVENIENCE OUTLET . . . . . 23 8 DISCONNECT/BLOWER ACCESS LOCATION . . . . . 29 9 TYPICAL APPLICATIONS . . . . . . . . . . . . . . . . . . . . . . 30 15 ELECT DATA - DH036, 048 & 060 BELT DRIVE WITH POWR’D CONVENIENCE OUTLET . . . . . . . . . . . . . . 24 10 FOUR AND SIX POINT LOADING . . . . . . . . . . . . . . . . 31 16 PHYSICAL DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 11 ROOF CURB DIMENSIONS . . . . . . . . . . . . . . . . . . . . 32 17 ELECTRIC HEAT CORRECTION FACTORS . . . . . . 25 10 SUPPLY AIR BLOWER PERFORMANCE (5 TON BELT DRIVE) - SIDE DUCT APPLICATION . . . . . . . . . . . . . 21 11 BELT DRIVE BLOWER MOTOR AND DRIVE DATA . 21 12 STATIC RESISTANCES . . . . . . . . . . . . . . . . . . . . . . . 22 18 VOLTAGE LIMITATIONS . . . . . . . . . . . . . . . . . . . . . . 25 19 UTILITIES ENTRY . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 20 MINIMUM CLEARANCES . . . . . . . . . . . . . . . . . . . . . . 29 21 DH 4 AND 6 POINT LOADS WEIGHT DISTRIBUTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 22 CENTER OF GRAVITY . . . . . . . . . . . . . . . . . . . . . . . . 31 23 OPERATING WEIGHTS (LBS.) . . . . . . . . . . . . . . . . . . 32 2 Unitary Products Group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nitary Products Group 3 036-21506-004-A-1105 PRODUCT NOMENCLATURE - Continued 3-6T Sunline Model Number Nomenclature Standard Cabinet AA AB AC AD AE AF AG AH AJ AK AL AM AN AS CA CB CC CD CE CF CG CH CJ CK CL CM CN CP CQ CR CS CT CU CV CW CX JA JB JC JD JE JF JG JH JJ JK JL JM JN JP JQ 4 None Phase Monitor Coil Guard Dirty Filter Switch Phase Monitor & Coil Guard Phase Monitor & Dirty Filter Switch Coil Guard & Dirty Filter Switch Phase Monitor, Coil Guard, & Dirty Filter Switch SS Drain Pan SS Drain Pan & Phase Monitor SS Drain Pan & Coil Guard SS Drain Pan & Dirty Filter Switch SS Drain Pan, Phase Monitor, Coil Guard & Dirty Filter Switch Bottom Drain Connection CPC Controller with Dirty Filter Switch & Air Proving Switch CPC Controller, DFS, APS & Phase Monitor CPC Controller, DFS, APS & Coil Guard CPC Controller, DFS, APS, Phase Monitor, & Coil Guard CPC Controller, DFS, APS & Technicoat Cond. Coil CPC Controller, DFS, APS, Technicoat Cond. Coil, & Phase Monitor CPC Controller, DFS, APS, Technicoat Cond. Coil, & Coil Guard CPC Controller, DFS, APS, Technicoat Cond. Coil, Phase Monitor, & Coil Guard CPC Controller, DFS, APS & Technicoat Evap. Coil CPC Controller, DFS, APS, Technicoat Evap. Coil, & Phase Monitor CPC Controller, DFS, APS, Technicoat Evap. Coil, & Coil Guard CPC Controller, DFS, APS, Technicoat Evap. Coil, Phase Monitor, & Coil Guard CPC Controller, DFS, APS & Technicoat Evap. & Cond Coils CPC Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Phase Monitor CPC Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Coil Guard CPC Controller, DFS, APS, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard CPC Controller, DFS, APS, SS Drain Pan CPC Controller, DFS, APS, SS Drain Pan, Phase Monitor, & Coil Guard CPC Controller, DFS, APS, SS Drain Pan, & Technicoat Cond Coils CPC Controller, DFS, APS, SS Drain Pan, & Technicoat Evap Coil CPC Controller, DFS, APS, SS Drain Pan, & Technicoat Evap and Cond Coils CPC Controller, DFS, APS, SS Drain Pan, Phase Monitor, Coil Guard, & Technicoat Evap and Cond Coils Johnson UNT Controller with Dirty Filter Switch & Air Proving Switch Johnson UNT Controller, DFS, APS & Phase Monitor Johnson UNT Controller, DFS, APS & Coil Guard Johnson UNT Controller, DFS, APS, Phase Monitor, & Coil Guard Johnson UNT Controller, DFS, APS & Technicoat Cond. Coil Johnson UNT Controller, DFS, APS, Technicoat Cond. Coil, & Phase Monitor Johnson UNT Controller, DFS, APS, Technicoat Cond. Coil, & Coil Guard Johnson UNT Controller, DFS, APS, Technicoat Cond. Coil, Phase Monitor, & Coil Guard Johnson UNT Controller, DFS, APS & Technicoat Evap. Coil Johnson UNT Controller, DFS, APS, Technicoat Evap. Coil, & Phase Monitor Johnson UNT Controller, DFS, APS, Technicoat Evap. Coil, & Coil Guard Johnson UNT Controller, DFS, APS, Technicoat Evap. Coil, Phase Monitor, & Coil Guard Johnson UNT Controller, DFS, APS & Technicoat Evap. & Cond Coils Johnson UNT Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Phase Monitor Johnson UNT Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Coil Guard Unitary Products Group 036-21506-004-A-1105 Standard Cabinet JR JS JT JU JV JW JX HA HB HC HD HE HF HG HH HJ HK HL HM HN HP HQ HR HS HT HU HV HW HX NA NB NC ND NE NF NG NH NJ NK NL NM NN NP NQ NR NS NT NU NV NW NX TA TB TC Johnson UNT Controller, DFS, APS, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard Johnson UNT Controller, DFS, APS, SS Drain Pan Johnson UNT Controller, DFS, APS, SS Drain Pan, Phase Monitor, & Coil Guard Johnson UNT Controller, DFS, APS, SS Drain Pan, & Technicoat Cond Coils Johnson UNT Controller, DFS, APS, SS Drain Pan, & Technicoat Evap Coil Johnson UNT Controller, DFS, APS, SS Drain Pan, & Technicoat Evap and Cond Coils Johnson UNT Controller, DFS, APS, SS Drain Pan, Phase Monitor, Coil Guard, & Technicoat Evap and Cond Coils Honeywell Excel 10 Controller with Dirty Filter Switch & Air Proving Switch Honeywell Excel 10 Controller, DFS, APS & Phase Monitor Honeywell Excel 10 Controller, DFS, APS & Coil Guard Honeywell Excel 10 Controller, DFS, APS, Phase Monitor, & Coil Guard Honeywell Excel 10 Controller, DFS, APS & Technicoat Cond. Coil Honeywell Excel 10 Controller, DFS, APS, Technicoat Cond. Coil, & Phase Monitor Honeywell Excel 10 Controller, DFS, APS, Technicoat Cond. Coil, & Coil Guard Honeywell Excel 10 Controller, DFS, APS, Technicoat Cond. Coil, Phase Monitor, & Coil Guard Honeywell Excel 10 Controller, DFS, APS & Technicoat Evap. Coil Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. Coil, & Phase Monitor Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. Coil, & Coil Guard Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. Coil, Phase Monitor, & Coil Guard Honeywell Excel 10 Controller, DFS, APS & Technicoat Evap. & Cond Coils Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Phase Monitor Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Coil Guard Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard Honeywell Excel 10 Controller, DFS, APS, SS Drain Pan Honeywell Excel 10 Controller, DFS, APS, SS Drain Pan, Phase Monitor, & Coil Guard Honeywell Excel 10 Controller, DFS, APS, SS Drain Pan, & Technicoat Cond Coils Honeywell Excel 10 Controller,DFS, APS, SS Drain Pan, & Technicoat Evap Coil Honeywell Excel 10 Controller,DFS, APS, SS Drain Pan, & Technicoat Evap and Cond Coils Honeywell Excel 10 Controller,DFS, APS, SS Drain Pan, Phase Monitor, Coil Guard, & Technicoat Evap and Cond Coils Novar ETC-3 Controller with Dirty Filter Switch & Air Proving Switch Novar ETC-3 Controller, DFS, APS & Phase Monitor Novar ETC-3 Controller, DFS, APS & Coil Guard Novar ETC-3 Controller, DFS, APS, Phase Monitor, & Coil Guard Novar ETC-3 Controller, DFS, APS & Technicoat Cond. Coil Novar ETC-3 Controller, DFS, APS, Technicoat Cond. Coil, & Phase Monitor Novar ETC-3 Controller, DFS, APS, Technicoat Cond. Coil, & Coil Guard Novar ETC-3 Controller, DFS, APS, Technicoat Cond. Coil, Phase Monitor, & Coil Guard Novar ETC-3 Controller, DFS, APS & Technicoat Evap. Coil Novar ETC-3 Controller, DFS, APS, Technicoat Evap. Coil, & Phase Monitor Novar ETC-3 Controller, DFS, APS, Technicoat Evap. Coil, & Coil Guard Novar ETC-3 Controller, DFS, APS, Technicoat Evap. Coil, Phase Monitor, & Coil Guard Novar ETC-3 Controller, DFS, APS & Technicoat Evap. & Cond Coils Novar ETC-3 Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Phase Monitor Novar ETC-3 Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Coil Guard Novar ETC-3 Controller, DFS, APS, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard Novar ETC-3 Controller, DFS, APS, SS Drain Pan Novar ETC-3 Controller, DFS, APS, SS Drain Pan, Phase Monitor, & Coil Guard Novar ETC-3 Controller, DFS, APS, SS Drain Pan, & Technicoat Cond Coils Novar ETC-3 Controller, DFS, APS, SS Drain Pan, & Technicoat Evap Coil Novar ETC-3, DFS, APS, SS Drain Pan, & Technicoat Evap and Cond Coils Novar ETC-3 Controller, DFS, APS, SS Drain Pan, Phase Monitor, Coil Guard, & Technicoat Evap and Cond Coils Technicoat Condenser Coil Technicoat Condenser Coil & Phase Monitor Technicoat Condenser Coil & Coil Guard Unitary Products Group 5 036-21506-004-A-1105 Standard Cabinet TD TE TF TG TH TJ TK TL TM TN TP TQ TR TS TT TU TV TW TX TY TZ T1 T3 T4 T6 T7 T9 LA LB LC LD LE LF LG LH LJ LK LL LM LN LP LQ LR LS LT LU LV LW LX WA WB WC WD WE 6 Technicoat Condenser Coil & Dirty Filter Switch Technicoat Condenser Coil, Phase Monitor, & Coil Guard Technicoat Condenser Coil, Phase Monitor, & Dirty Filter Switch Technicoat Condenser Coil, Coil Guard, & Dirty Filter Switch Technicoat Condenser Coil, Phase Monitor, Coil Guard, & Dirty Filter Switch Technicoat Evaporator Coil Technicoat Evaporator Coil & Phase Monitor Technicoat Evaporator Coil & Coil Guard Technicoat Evaporator Coil & Dirty Filter Switch Technicoat Evaporator Coil, Phase Monitor, & Coil Guard Technicoat Evaporator Coil, Phase Monitor, & Dirty Filter Switch Technicoat Evaporator Coil, Coil Guard, & Dirty Filter Switch Technicoat Evaporator Coil, Phase Monitor, Coil Guard, & Dirty Filter Switch Technicoat Evaporator & Condenser Coils Technicoat Evaporator & Condenser Coils & Phase Monitor Technicoat Evaporator & Condenser Coils & Coil Guard Technicoat Evaporator & Condenser Coils & Dirty Filter Switch Technicoat Evaporator & Condenser Coils, Phase Monitor, & Coil Guard Technicoat Evaporator & Condenser Coils, Phase Monitor, & Dirty Filter Switch Technicoat Evaporator & Condenser Coils, Coil Guard, & Dirty Filter Switch Technicoat Evaporator & Condenser Coils, Phase Monitor, Coil Guard, & Dirty Filter Switch Technicoat Condenser & SS Drain Pan Technicoat Condenser Coil, SS Drain Pan, Phase Monitor, Coil Guard, & Dirty Filter Switch Technicoat Evaporator & SS Drain Pan Technicoat Evaporator Coil, SS Drain Pan, Phase Monitor, Coil Guard, & Dirty Filter Switch Technicoat Evaporator & Condenser Coils & SS Drain Pan Technicoat Evaporator & Condenser Coils, SS Drain Pan, Phase Monitor, Coil Guard, & Dirty Filter Switch Simplicity Intelli-Comfort Controller Simplicity Intelli-Comfort Controller, & Phase Monitor Simplicity Intelli-Comfort Controller, & Coil Guard Simplicity Intelli-Comfort Controller, Phase Monitor, & Coil Guard Simplicity Intelli-Comfort Controller, & Technicoat Cond. Coil Simplicity Intelli-Comfort Controller, Technicoat Cond. Coil, & Phase Monitor Simplicity Intelli-Comfort Controller, Technicoat Cond. Coil, & Coil Guard Simplicity Intelli-Comfort Controller, Technicoat Cond. Coil, Phase Monitor, & Coil Guard Simplicity Intelli-Comfort Controller, & Technicoat Evap. Coil Simplicity Intelli-Comfort Controller, Technicoat Evap. Coil, & Phase Monitor Simplicity Intelli-Comfort Controller, Technicoat Evap. Coil, & Coil Guard Simplicity Intelli-Comfort Controller, Technicoat Evap. Coil, Phase Monitor, & Coil Guard Simplicity Intelli-Comfort Controller, & Technicoat Evap. & Cond Coils Simplicity Intelli-Comfort Controller, Technicoat Evap. & Cond Coils, & Phase Monitor Simplicity Intelli-Comfort Controller, Technicoat Evap. & Cond Coils, & Coil Guard Simplicity Intelli-Comfort Controller, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard Simplicity Intelli-Comfort Controller, SS Drain Pan Simplicity Intelli-Comfort Controller, SS Drain Pan, Phase Monitor, & Coil Guard Simplicity Intelli-Comfort Controller, SS Drain Pan, & Technicoat Cond Coils Simplicity Intelli-Comfort Controller, SS Drain Pan, & Technicoat Evap Coil Simplicity Intelli-Comfort Controller, SS Drain Pan, & Technicoat Evap and Cond Coils Simplicity Intelli-Comfort Controller, SS Drain Pan, Phase Monitor, Coil Guard, & Technicoat Evap and Cond Coils Intelli-Comfort w/Mod Link Controller Intelli-Comfort w/Mod Link Controller, & Phase Monitor Intelli-Comfort w/Mod Link Controller, & Coil Guard Intelli-Comfort w/Mod Link Controller, Phase Monitor, & Coil Guard Intelli-Comfort w/Mod Link Controller, & Technicoat Cond. Coil Unitary Products Group 036-21506-004-A-1105 Standard Cabinet WF WG WH WJ WK WL WM WN WP WQ WR WS WT WU WV WW WX Intelli-Comfort w/Mod Link Controller, Technicoat Cond. Coil, & Phase Monitor Intelli-Comfort w/Mod Link Controller, Technicoat Cond. Coil, & Coil Guard Intelli-Comfort w/Mod Link Controller, Technicoat Cond. Coil, Phase Monitor, & Coil Guard Intelli-Comfort w/Mod Link Controller, & Technicoat Evap. Coil Intelli-Comfort w/Mod Link Controller, Technicoat Evap. Coil, & Phase Monitor Intelli-Comfort w/Mod Link Controller, Technicoat Evap. Coil, & Coil Guard Intelli-Comfort w/Mod Link Controller, Technicoat Evap. Coil, Phase Monitor, & Coil Guard Intelli-Comfort w/Mod Link Controller, & Technicoat Evap. & Cond Coils Intelli-Comfort w/Mod Link Controller, Technicoat Evap. & Cond Coils, & Phase Monitor Intelli-Comfort w/Mod Link Controller, Technicoat Evap. & Cond Coils, & Coil Guard Intelli-Comfort w/Mod Link Controller, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard Intelli-Comfort w/Mod Link Controller, SS Drain Pan Intelli-Comfort w/Mod Link Controller, SS Drain Pan, Phase Monitor, & Coil Guard Intelli-Comfort w/Mod Link Controller, SS Drain Pan, & Technicoat Cond Coils Intelli-Comfort w/Mod Link Controller, SS Drain Pan, & Technicoat Evap Coil Intelli-Comfort w/Mod Link Controller, SS Drain Pan, & Technicoat Evap and Cond Coils Intelli-Comfort w/Mod Link Controller, SS Drain Pan, Phase Monitor, Coil Guard, & Technicoat Evap and Cond Coils Hinged Filter Door & Toolless Access Cabinet BA BB BC BD BE BF BG BH BJ BK BL BM BN BS DA DB DC DD DE DF DG DH DJ DK DL DM DN DP DQ DR DS DT DU DV DW Hinged Filter Door & Toolless Access Panels Phase Monitor, Hinged Filter Door & Toolless Access Panels Coil Guard, Hinged Filter Door & Toolless Access Panels Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels Phase Monitor & Coil Guard, Hinged Filter Door & Toolless Access Panels Phase Monitor & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels Coil Guard & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels Phase Monitor, Coil Guard, & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels SS Drain Pan & Hinged Filter Door & Toolless Access Panels SS Drain Pan & Phase Monitor, Hinged Filter Door & Toolless Access Panels SS Drain Pan & Coil Guard, Hinged Filter Door & Toolless Access Panels SS Drain Pan & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels SS Drain Pan & Phase Monitor & Coil Guard, Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels Bottom Drain Connection, Hinged Filter Door & Toolless Access Panels CPC Controller with Dirty Filter Switch & Air Proving Switch, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS & Phase Monitor, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS & Coil Guard, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS & Technicoat Cond. Coil, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, Technicoat Cond. Coil, & Phase Monitor, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, Technicoat Cond. Coil, & Coil Guard, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, Technicoat Cond. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS & Technicoat Evap. Coil, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, Technicoat Evap. Coil, & Phase Monitor, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, Technicoat Evap. Coil, & Coil Guard, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, Technicoat Evap. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS & Technicoat Evap. & Cond Coils, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Phase Monitor, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Coil Guard, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, SS Drain Pan Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, SS Drain Pan, Phase Monitor, & Coil Guard Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, SS Drain Pan, & Technicoat Cond Coils Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, SS Drain Pan, & Technicoat Evap Coil Hinged Filter Door & Toolless Access Panels CPC Controller, DFS, APS, SS Drain Pan, & Technicoat Evap and Cond Coils Hinged Filter Door & Toolless Access Panels Unitary Products Group 7 036-21506-004-A-1105 Hinged Filter Door & Toolless Access Cabinet DX EA EB EC ED EE EF EG EH EJ EK EL EM EN EP EQ ER ES ET EU EV EW EX GA GB GC GD GE GF GG GH GJ GK GL GM GN GP GQ GR GS GT GU GV GW GX PA PB 8 CPC Controller, DFS, APS, SS Drain Pan, Phase Monitor, Coil Guard, & Technicoat Evap and Cond Coils Hinged Filter Door & Toolless Access Panels Johnson UNT Controller with Dirty Filter Switch & Air Proving Switch, Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS & Phase Monitor, Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS & Coil Guard, Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS & Technicoat Cond. Coil, Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS, Technicoat Cond. Coil, & Phase Monitor, Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS, Technicoat Cond. Coil, & Coil Guard, Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS, Technicoat Cond. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS & Technicoat Evap. Coil, Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS, Technicoat Evap. Coil, & Phase Monitor, Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS, Technicoat Evap. Coil, & Coil Guard, Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS, Technicoat Evap. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS & Technicoat Evap. & Cond Coils, Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Phase Monitor, Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Coil Guard, Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS, SS Drain Pan Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS, SS Drain Pan, Phase Monitor, & Coil Guard Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS, SS Drain Pan, & Technicoat Cond Coils Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS, SS Drain Pan, & Technicoat Evap Coil Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS, SS Drain Pan, & Technicoat Evap and Cond Coils Hinged Filter Door & Toolless Access Panels Johnson UNT Controller, DFS, APS, SS Drain Pan, Phase Monitor, Coil Guard, & Technicoat Evap and Cond Coils Hinged Filter Door & Toolless Access Panels Honeywell Excel 10 Controller with Dirty Filter Switch & Air Proving Switch, Hinged Filter Door & Toolless Access Panels Honeywell Excel 10 Controller, DFS, APS & Phase Monitor, Hinged Filter Door & Toolless Access Panels Honeywell Excel 10 Controller, DFS, APS & Coil Guard, Hinged Filter Door & Toolless Access Panels Honeywell Excel 10 Controller, DFS, APS, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels Honeywell Excel 10 Controller, DFS, APS & Technicoat Cond. Coil, Hinged Filter Door & Toolless Access Panels Honeywell Excel 10 Controller, DFS, APS, Technicoat Cond. Coil, & Phase Monitor, Hinged Filter Door & Toolless Access Panels Honeywell Excel 10 Controller, DFS, APS, Technicoat Cond. Coil, & Coil Guard, Hinged Filter Door & Toolless Access Panels Honeywell Excel 10 Controller, DFS, APS, Technicoat Cond. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels Honeywell Excel 10 Controller, DFS, APS & Technicoat Evap. Coil, Hinged Filter Door & Toolless Access Panels Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. Coil, & Phase Monitor, Hinged Filter Door & Toolless Access Panels Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. Coil, & Coil Guard, Hinged Filter Door & Toolless Access Panels Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels Honeywell Excel 10 Controller, DFS, APS & Technicoat Evap. & Cond Coils, Hinged Filter Door & Toolless Access Panels Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Phase Monitor, Hinged Filter Door & Toolless Access Panels Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Coil Guard, Hinged Filter Door & Toolless Access Panels Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels Honeywell Excel 10 Controller, DFS, APS, SS Drain Pan Honeywell Excel 10 Controller, DFS, APS, SS Drain Pan, Phase Monitor, & Coil Guard Honeywell Excel 10 Controller, DFS, APS, SS Drain Pan, & Technicoat Cond Coils Honeywell Excel 10 Controller,DFS, APS, SS Drain Pan, & Technicoat Evap Coil Honeywell Excel 10 Controller,DFS, APS, SS Drain Pan, & Technicoat Evap and Cond Coils Honeywell Excel 10 Controller,DFS, APS, SS Drain Pan, Phase Monitor, Coil Guard, & Technicoat Evap and Cond Coils Novar ETC-3 Controller with Dirty Filter Switch & Air Proving Switch, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS & Phase Monitor, Hinged Filter Door & Toolless Access Panels Unitary Products Group 036-21506-004-A-1105 Hinged Filter Door & Toolless Access Cabinet PC PD PE PF PG PH PJ PK PL PM PN PP PQ PR Novar ETC-3 Controller, DFS, APS & Coil Guard, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS & Technicoat Cond. Coil, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS, Technicoat Cond. Coil, & Phase Monitor, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS, Technicoat Cond. Coil, & Coil Guard, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS, Technicoat Cond. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS & Technicoat Evap. Coil, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS, Technicoat Evap. Coil, & Phase Monitor, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS, Technicoat Evap. Coil, & Coil Guard, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS, Technicoat Evap. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS & Technicoat Evap. & Cond Coils, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Phase Monitor, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Coil Guard, Hinged Filter Door & Toolless Access Panels Novar ETC-3 Controller, DFS, APS, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels PS Novar ETC-3 Controller, DFS, APS, SS Drain Pan PT Novar ETC-3 Controller, DFS, APS, SS Drain Pan, Phase Monitor, & Coil Guard PU Novar ETC-3 Controller, DFS, APS, SS Drain Pan, & Technicoat Cond Coils PV Novar ETC-3 Controller, DFS, APS, SS Drain Pan, & Technicoat Evap Coil PW Novar ETC-3, DFS, APS, SS Drain Pan, & Technicoat Evap and Cond Coils PX Novar ETC-3 Controller, DFS, APS, SS Drain Pan, Phase Monitor, Coil Guard, & Technicoat Evap and Cond Coils UA Technicoat Condenser Coil, Hinged Filter Door & Toolless Access Panels UB Technicoat Condenser Coil & Phase Monitor, Hinged Filter Door & Toolless Access Panels UC Technicoat Condenser Coil & Coil Guard, Hinged Filter Door & Toolless Access Panels UD Technicoat Condenser Coil & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels UE Technicoat Condenser Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels UF Technicoat Condenser Coil, Phase Monitor, & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels UG Technicoat Condenser Coil, Coil Guard, & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels UH Technicoat Condenser Coil, Phase Monitor, Coil Guard, & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels UJ Technicoat Evaporator Coil, Hinged Filter Door & Toolless Access Panels UK Technicoat Evaporator Coil & Phase Monitor, Hinged Filter Door & Toolless Access Panels UL Technicoat Evaporator Coil & Coil Guard, Hinged Filter Door & Toolless Access Panels UM Technicoat Evaporator Coil & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels UN Technicoat Evaporator Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels UP Technicoat Evaporator Coil, Phase Monitor, & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels UQ Technicoat Evaporator Coil, Coil Guard, & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels UR Technicoat Evaporator Coil, Phase Monitor, Coil Guard, & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels US Technicoat Evaporator & Condenser Coils, Hinged Filter Door & Toolless Access Panels UT Technicoat Evaporator & Condenser Coils & Phase Monitor, Hinged Filter Door & Toolless Access Panels UU Technicoat Evaporator & Condenser Coils & Coil Guard, Hinged Filter Door & Toolless Access Panels UV Technicoat Evaporator & Condenser Coils & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels UW Technicoat Evaporator & Condenser Coils, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels UX Technicoat Evaporator & Condenser Coils, Phase Monitor, & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels UY Technicoat Evaporator & Condenser Coils, Coil Guard, & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels UZ Technicoat Evaporator & Condenser Coils, Phase Monitor, Coil Guard, & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels U1 Technicoat Condenser & SS Drain Pan, Hinged Filter Door & Toolless Access Panels U3 Technicoat Condenser Coil, SS Drain Pan, Phase Monitor, Coil Guard, & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels U4 Technicoat Evaporator & SS Drain Pan, Hinged Filter Door & Toolless Access Panels U6 Technicoat Evaporator Coil, SS Drain Pan, Phase Monitor, Coil Guard, & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels U7 Technicoat Evaporator & Condenser Coils & SS Drain Pan, Hinged Filter Door & Toolless Access Panels U9 Technicoat Evaporator & Condenser Coils, SS Drain Pan, Phase Monitor, Coil Guard, & Dirty Filter Switch, Hinged Filter Door & Toolless Access Panels QA Simplicity Intelli-Comfort Controller with Hinged Filter Door & Toolless Access Panels QB Simplicity Intelli-Comfort Controller, & Phase Monitor, Hinged Filter Door & Toolless Access Panels QC Simplicity Intelli-Comfort Controller, & Coil Guard, Hinged Filter Door & Toolless Access Panels Unitary Products Group 9 036-21506-004-A-1105 Hinged Filter Door & Toolless Access Cabinet QD QE QF QG QH QJ QK QL QM QN QP QQ QR QS QT QU QV QW QX Simplicity Intelli-Comfort Controller, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, & Technicoat Cond. Coil, Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, Technicoat Cond. Coil, & Phase Monitor, Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, Technicoat Cond. Coil, & Coil Guard, Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, Technicoat Cond. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Simplicity Intelli-Comfort Controller, & Technicoat Evap. Coil, Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, Technicoat Evap. Coil, & Phase Monitor, Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, Technicoat Evap. Coil, & Coil Guard, Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, Technicoat Evap. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Simplicity Intelli-Comfort Controller, & Technicoat Evap. & Cond Coils, Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, Technicoat Evap. & Cond Coils, & Phase Monitor, Hinged Filter Door & Toolless Access Pan Simplicity Intelli-Comfort Controller, Technicoat Evap. & Cond Coils, & Coil Guard, Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolles Simplicity Intelli-Comfort Controller, SS Drain Pan Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, SS Drain Pan, Phase Monitor, & Coil Guard Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, SS Drain Pan, & Technicoat Cond Coils Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, SS Drain Pan, & Technicoat Evap Coil Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, SS Drain Pan, & Technicoat Evap and Cond Coils Hinged Filter Door & Toolless Access Panels Simplicity Intelli-Comfort Controller, SS Drain Pan, Phase Monitor, Coil Guard, & Technicoat Evap and Cond Coils Hinged Filter Door & Toolless Access Panels XA Intelli-Comfort w/Mod Link Controller, Hinged Filter Door & Toolless Access Panels XB Intelli-Comfort w/Mod Link Controller, & Phase Monitor, Hinged Filter Door & Toolless Access Panels XC Intelli-Comfort w/Mod Link Controller, & Coil Guard, Hinged Filter Door & Toolless Access Panels XD Intelli-Comfort w/Mod Link Controller, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access Panels XE Intelli-Comfort w/Mod Link Controller, & Technicoat Cond. Coil, Hinged Filter Door & Toolless Access Panels XF Intelli-Comfort w/Mod Link Controller, Technicoat Cond. Coil, & Phase Monitor, Hinged Filter Door & Toolless Access Panels XG Intelli-Comfort w/Mod Link Controller, Technicoat Cond. Coil, & Coil Guard, Hinged Filter Door & Toolless Access Panels XH Intelli-Comfort w/Mod Link Controller, Technicoat Cond. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access XJ Intelli-Comfort w/Mod Link Controller, & Technicoat Evap. Coil, Hinged Filter Door & Toolless Access Panels XK Intelli-Comfort w/Mod Link Controller, Technicoat Evap. Coil, & Phase Monitor, Hinged Filter Door & Toolless Access Panels XL Intelli-Comfort w/Mod Link Controller, Technicoat Evap. Coil, & Coil Guard, Hinged Filter Door & Toolless Access Panels XM Intelli-Comfort w/Mod Link Controller, Technicoat Evap. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolless Access XN Intelli-Comfort w/Mod Link Controller, & Technicoat Evap. & Cond Coils, Hinged Filter Door & Toolless Access Panels XP Intelli-Comfort w/Mod Link Controller, Technicoat Evap. & Cond Coils, & Phase Monitor, Hinged Filter Door & Toolless Access Pan XQ Intelli-Comfort w/Mod Link Controller, Technicoat Evap. & Cond Coils, & Coil Guard, Hinged Filter Door & Toolless Access Panels XR Intelli-Comfort w/Mod Link Controller, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard, Hinged Filter Door & Toolles XS Intelli-Comfort w/Mod Link Controller, SS Drain Pan Hinged Filter Door & Toolless Access Panels XT Intelli-Comfort w/Mod Link Controller, SS Drain Pan, Phase Monitor, & Coil Guard Hinged Filter Door & Toolless Access Panels XU Intelli-Comfort w/Mod Link Controller, SS Drain Pan, & Technicoat Cond Coils Hinged Filter Door & Toolless Access Panels XV Intelli-Comfort w/Mod Link Controller, SS Drain Pan, & Technicoat Evap Coil Hinged Filter Door & Toolless Access Panels XW Intelli-Comfort w/Mod Link Controller, SS Drain Pan, & Technicoat Evap and Cond Coils Hinged Filter Door & Toolless Access Panels XX Intelli-Comfort w/Mod Link Controller, SS Drain Pan, Phase Monitor, Coil Guard, & Technicoat Evap and Cond Coils Hinged Filter Door & Toolless Access Panels 10 Unitary Products Group 036-21506-004-A-1105 FEATURES switch on gas heat units. The unit control board will alarm on ignition failures, compressor lockouts and repeated limit switch trips. All models are available with a wide variety of factorymounted options such as stainless steel heat exchangers, electric heaters, phase monitor, convenience outlet, dirty filter switch, disconnect switch, smoke detectors, and coil guard to make them suitable for almost every application. All units are self-contained and assembled on full perimeter base rails with forklift holes on three sides and holes for overhead rigging. Every unit is completely piped, wired, charged and tested at the factory to simplify the field installation and to provide years of dependable operation. All models (including those with an economizer) are suitable for either bottom or horizontal duct connections. For bottom duct, remove the sheet metal panels from the supply and return air openings through the base of the unit. For horizontal duct, remove the supply and return air panels on the rear of the unit. • Nuisance Trip Protection- To prevent nuisance trouble calls, the control board uses a “three strikes, you’re out” philosophy. The high and low-pressure switches and the freezestats must trip three times within two hours before the unit control board will lock out the compressor. • On Board Diagnostics - Each alarm will energize a trouble light on the thermostat, if so equipped, and flash an alarm code on the control board LED. Each high and low-pressure switch alarm as well as each freezestat alarm has its own flash code. The control board saves the five most recent alarms in memory, and these alarms can be reviewed at any time. Alarms and programmed values are retained through the loss of power. All models are available with these “factory mounted” outdoor air damper options: All units have long lasting powder paint cabinets with 1000 hour salt spray test approval under ASTM-B117 procedures. • Single enthalpy economizer All models are CSA listed. • Motorized outdoor air damper • Warranty - All models include a one-year limited parts warranty on the complete unit. Compressors and electric heater elements carry a five-year warranty. Gas heat exchangers carry a 10-year parts warranty. • Gas Heat Operation - All single phase models with gas heat have minimum annual fuel utilization efficiency (AFUE) of 80%. All three phase models with gas heat have minimum steady state efficiency of 80%. Each section includes a durable heat exchanger with aluminized steel or optional stainless steel tubes, a redundant gas valve, spark ignition, power venting, an ignition module for 100% shut-off and all of the safety controls required to meet the latest ANSI standards. Supply air blowers are equipped with a belt drive that can be adjusted to meet the exact requirements of the job. All compressors are equipped with internal pressure relief. Every refrigerant circuit includes a liquid line filter-drier, a high pressure switch and a suction line with a freezestat and low pressure/loss of charge switch to protect all system components. • Simplicity™ Controls - Simplicity™ control boards have standardized a number of features previously available only as options or by utilizing additional controls. • Low Ambient - An integrated low-ambient control allows all units to operate in the cooling mode down to 0ºF outdoor ambient without additional assistance. Optionally, the control board can be programmed to lockout the compressors when the outdoor air temperature is low or when free cooling is available. • Anti-Short Cycle Protection - To aid compressor life, an anti-short cycle delay is incorporated into the standard controls. Compressor reliability is further ensured by programmable minimum run times. For testing, the anti short cycle delay can be temporarily overridden with the push of a button. • Fan Delays - Fan on and fan off delays are fully programmable and are independent of one another. All units are programmed with default values based upon their configuration of cooling and heat. • Safety Monitoring - The control board monitors the high and low-pressure switches, the freezestats, the gas valve, if applicable, and the temperature limit Unitary Products Group The gas supply piping can be routed into the heating compartment through a hole in the base pan of the unit or through a knockout in the piping panel on the front of the unit. • Electric Heat Operation - All electric heat models are wired for a single power source and include a bank of nickel chromium elements mounted at the discharge of the supply air blower to provide a high velocity and uniform distribution of air across the heating elements. Every element is fully protected against excessive temperature by thermal limit switches. The power supply wiring can be routed into the control box through a threaded pipe connection (field supplied) in the base pan of the unit or through a knockout in the wiring panel on the side of the unit. • BAS Controls - York’s Sunline™ series units offer factory mounted BAS controls such as SImplicity™ INTELLIComfort™, Novar, Honeywell, Johnson, and CPC. 11 036-21506-004-A-1105 FIGURE 1 - UNIT CUTAWAY FACTORY-INSTALLED OPTIONS • SINGLE INPUT ELECTRONIC ENTHALPY ECONOMIZERS - Includes a slide-in / plug-in damper assembly with fully modulating spring-return motor actuator capable of introducing up to 100% outdoor air with nominal 1% leakage type dampers. The enthalpy system contains one sensor that monitors the outdoor air and determines when the air is cool enough and dry enough to provide free cooling. The rainhood is painted to match the basic unit and must be field-assembled before installing. • MOTORIZED OUTDOOR AIR INTAKE DAMPER Includes a slide-in / plug-in damper assembly with a 2position, spring return motor actuator which opens to a pre-set position whenever the supply air blower is operating and will drive fully closed when the blower unit shuts down. The rain hood is painted to match the basic unit and must be field assembled before installing. • 12 PHENOLIC COATED EVAPORATOR AND CONDENSER COILS - Special coating process that utilizes Technicoat 10-1TM processes. Coating is applied by total immersion of the complete coil for maximum protection. • ELECTRIC HEATERS - Wired for single point power supply. These nickel chromium heater elements are provided with limit and automatic reset capability to prevent operation at excessive temperatures. • FILTER OPTIONS - Standard units are shipped with 1” throw-away filters installed. 2” pleated filters are offered as a factory installed option. • CONVENIENCE OUTLET - This 110 volt outlet can be “powered” by the unit with a stepdown transformer or the unit may be ordered with a “non-powered” convenience outlet that can be wired in the field. • DISCONNECT SWITCH - For gas heat units and cooling units with electric heat, a HACR breaker sized to the unit is provided. For cooling only units, a switch sized to the largest electric heat available for the particular unit is provided. Factory installed option only. • BAS - Building Automation System Controls Simplicity™ INTELLI-Comfort™ CONTROL - The York® Simplicity™ INTELLI-Comfort™ control is factory installed. It includes a supply air sensor, a return air sensor, and an outside air sensor. There are provisions for a field installed dirty filter indicator switch, an air-proving switch, an Outside Air Humidity sensor, a Return Air Humidity sensor, an Inside IAQ sensor, and an Outside Air IAQ sensor. Construction mode operation, 365-day real time clock with 7 day programming plus holiday Unitary Products Group 036-21506-004-A-1105 • • • • scheduling is built-in. Two different modes of demand ventilation are achieved through the INTELLI-Comfort™using CO2 sensors. It uses an inside CO2 sensor to perform Demand Ventilation. It can also use an Outside CO2 sensor to perform Differential Demand Ventilation. It uses a Patented Comfort Ventilation algorithm to provide comfortable ventilation air temperature. The patented economizer-loading algorithm will protect the equipment when harsh operating conditions exist. Humidity in the occupied space or return duct can be monitored and controlled via humidity sensors and the on-board connection for hot gas re-heat system. It uses the INTELLI-Start™ algorithm to maximize energy savings by recovering the building from the Unoccupied Setpoints to the Occupied Setpoints just in time for the Occupied Time Period to begin. The Simplicity™ INTELLI-Comfort™ balances space temperature, ventilation air temperature, CO2 and humidity for ultimate comfort. • STAINLESS STEEL DRAIN PAN - An optional rustproof stainless steel drain pan is available to provide years of trouble-free operation in corrosive environments. • BOTTOM DRAIN CONNECTION - An optional bottom drain connection is available for inside the curb connections for applications in cold environments to reduce freezing drain lines. • PHASE MONITORS - Designed to prevent unit damage. The phase monitor will shut the unit down in an out-ofphase condition. • DIRTY FILTER SWITCH - This kit includes a differential pressure switch that energizes the fault light on the unit thermostat, indicating that there is an abnormally high pressure drop across the filters. Factory installed option or field installed accessory. Simplicity™ INTELLI-Comfort™ with MOD LINK CONTROL - The York® Simplicity™ INTELLI-Comfort™ with Mod Link control is factory installed. It includes all the features of the INTELLI-Comfort™ control with an additional control to translate communications from MODBUS to the BACnet MSTP protocol. • HINGED FILTER DOOR/“TOOLLESS” BLOWER AND ACCESS PANELS (not hinged) - This option allows for easy access and maintenance. Novar® BAS CONTROL - The Novar® ETC-3 building automation system controller is factory installed. Includes supply air sensor, return air sensor, dirty filter indicator switch, and air proving switch. NOTE:Knobs are shipped inside the unit to prevent shipping damage. These must be field installed for tool-less operation. FIELD-INSTALLED ACCESSORIES • JOHNSON CONTROLS BAS CONTROL - The Johnson Control YK-UNT-1126 building automation system controller is factory installed. Includes supply air sensor, return air sensor, dirty filter indicator switch, and air proving switch. The enthalpy system contains one sensor that monitors the outdoor air and determines when the air is cool enough and dry enough to provide free cooling. CPC BAS CONTROL - The Computer Process Controls Model 810-3060 ARTC Advanced Rooftop building automation system controller is factory installed. Includes supply air sensor, return air sensor, dirty filter indicator switch and air proving switch. • HONEYWELL BAS CONTROL - The Honeywell W7750C building automation system controller is factory installed. Includes air supply sensor, return air sensor, dirty filter indicator switch, and air proving switch. • SMOKE DETECTORS - (supply air & return air) The smoke detectors stop operation of the unit by interrupting power to the control board if smoke is detected within the air compartment. • COIL GUARD - Customers can purchase a coil guard kit to protect the condenser coil from damage. This is not a hail guard kit. • STAINLESS STEEL HEAT EXCHANGER - For applications in corrosive environments, this option provides a full stainless steel heat exchanger assembly. Unitary Products Group SINGLE INPUT ELECTRONIC ENTHALPY ECONOMIZERS - Includes a slide-in / plug-in damper assembly with fully modulating spring-return motor actuator capable of introducing up to 100% outdoor air with nominal 1% leakage type dampers. The rainhood is painted to match the basic unit and must be field-assembled before installing. • MOTORIZED OUTDOOR AIR INTAKE DAMPER Includes a slide-in / plug-in damper assembly with a 2position, spring return motor actuator which opens to some pre-set position whenever the supply air blower is operating and will drive fully closed when the blower unit shuts down. The rain hood is painted to match the basic unit and must be field assembled before installing. • ELECTRIC HEATERS wired for single point power supply. These nickel chromium heater elements are provided with limit and automatic reset capability to prevent operation at excessive temperatures. 13 036-21506-004-A-1105 • • • • • Roof curbs are designed to fit inside the base rails of the unit and include both a wood nailing strip and duct hanger supports. BAROMETRIC RELIEF DAMPER - This damper accessory can be used to relieve internal building air pressure on units with an economizer without power exhaust. This accessory includes a rain hood, a bird screen and a fully assembled damper. With bottom duct connections, the damper should be mounted over the opening in the return air panel. With horizontal ductwork, the accessory should be mounted on the return air duct. • HIGH ALTITUDE NATURAL GAS - Burner orifices and pilot orifices are provided for proper furnace operation at altitudes up to 6,000 feet. ENTHALPY ACCESSORY CONTROL KIT - This kit contains the required components to convert a single enthalpy economizer to dual enthalpy. • BURGLAR BARS - Mount in the supply and return openings to prevent entry into the duct work. • FLUE EXHAUST EXTENSION KIT - In locations with wind or weather conditions which may interfere with proper exhausting of furnace combustion products, this kit can be installed to prevent the flue exhaust from entering nearby fresh air intakes. • CO2 SENSOR - Senses CO2 levels and automatically overrides the economizer when levels rise above the present limits. ROOF CURBS - Eight and fourteen-inch high roof curbs provide a water-tight seal between the unit and the finished roof. These full perimeter curbs meet the requirements of the National Roofing Contractors Association (NRCA) and are shipped knocked-down for field assembly. PROPANE - Burner orifices, pilot orifices and gas valve parts are provided to convert a natural gas furnace to propane. HIGH ALTITUDE PROPANE - Burner orifices and pilot orifices are provided for proper furnace operation at altitudes up to 6,000 feet. This accessory supplements the basic propane conversion kit. • LOW NOX KIT - Required to reduce the emission of nitrogen oxides below 40 nano grams per joule. • POWER EXHAUST - Our single input economizer options are available with power exhaust. Whenever the outdoor air intake dampers are opened for free cooling, the exhaust fan will be energized to prevent the conditioned space from being over-pressurized during economizer operation. • COIL GUARD - Customers can purchase a coil guard kit to protect the condenser coil from damage. This is not a hail guard kit. • HAIL GUARD - Hail Guard kit is available to prevent unit from hail damage. This is a sloped hood that fits above the coil. The power exhaust option can only be used on bottom duct configurations. • GAS PIPING KIT - This kit supplies all necessary fittings and shut off valve. 14 Unitary Products Group 036-21506-004-A-1105 TABLE 1: SOUND POWER RATING1 UNIT SIZE ESP SOUND POWER (db 10-12 Watts) BLOWER Octave Band Centerline Frequency (Hz) CFM IWG SPEED KW 63 125 250 500 1,000 2,000 4,000 8,000 SWL dB(A) dB(A) @ 10Ft.2 036 1,200 0.6 LOW 0.60 84 84 74 67 69 62 57 52 74 41 048 1,600 0.55 HIGH 0.80 85 85 75 68 70 63 58 53 75 42 060 2,000 0.45 HIGH 1.00 86 86 76 69 71 64 59 54 76 43 1. These values have been accessed using a model of sound propagation from a point source into the hemispheric\free field. The dBA values provided are to be used for reference only. Calculation of dBA values cover matters of system design and the fan manufacture has no way of knowing the details of each system. This constitutes and expectation to any specification or guarantee requiring a dBA value or sound data in any other form than sound power level ratings. 2. At a distance of 10 feet from the blower. TABLE 3: GAS HEAT RATINGS1 TABLE 2: CAPACITY RATINGS - (ARI 210/240)1 MODEL MBH EER2 SEER3 DH036 42.5 11.1 12.25 DH048 46.5 11.4 13.20 DH060 57.0 10.6 12.20 1. 80/67°F Indoor and 95°F outdoor. 2. EER = Energy Efficiency Ratio at full load - the cooling capacity in Btu’s per hour (Btuh) divided by the power input in watts, expressed in Btuh per watt (Btuh/watt). 3. SEER = Seasonal Energy Efficiency Ratio. MODEL MBH INPUT MBH OUTPUT AFUE (%) TEMP RISE ºF DH036N04 DH036N08 50 100 40 80 80.9 80.5 15 - 45 40 - 70 DH048N06 DH048N10 75 125 60 100 80.9 80.3 25 - 55 45 - 75 DH060N08 DH060N10 100 125 80 100 80.5 80.3 25 - 55 35 - 65 1. All units are single-stage heating. TABLE 4: 2 STAGE GAS HEAT RATINGS MODEL1 MBH INPUT MBH OUTPUT 1ST STAGE 2ND STAGE 1ST STAGE 2ND STAGE STEADY STATE EFFICIENCY 1ST STAGE 2ND STAGE RISE MIN. MAX. MINIMUM HEATING AIRFLOW (CFM) DH036D06 45 75 35.8 60.8 79.4 81.1 35 70 790 DH036D10 69 115 55.2 92 80.0 80.2 55 90 950 DH048D06 45 75 35.7 60.8 79.4 81.1 25 70 790 DH048D10 75 125 60.4 100.6 80.5 80.5 45 75 1230 DH060D06 45 75 35.8 60.8 79.4 81.1 35 70 1010 DH060D10 75 125 60.4 100.6 80.5 80.5 45 75 1230 1. Models are 3Ø only. Unitary Products Group 15 036-21506-004-A-1105 TABLE 5: DH036 COOLING CAPACITIES (3 TON) TEMPERATURE OF AIR ON CONDENSER COIL AIR ON EVAPORATOR COIL 85°F TOTAL 1 CFM 1500 1350 1200 1050 900 POWER CAP. MBH INPUT2 kW WB °F 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 55.2 49.1 44.7 42.4 55.2 49.1 44.7 42.4 51.9 46.1 42.0 39.8 49.4 43.9 40.0 37.9 46.9 41.7 38.0 36.0 3.18 3.13 3.05 3.05 3.18 3.13 3.05 3.05 3.15 3.10 3.02 3.03 3.12 3.07 2.99 3.00 3.09 3.04 2.96 2.97 95°F SENSIBLE CAPACITY1 ENTERING DRY BULB, °F TOTAL 1 SENSIBLE CAPACITY1 ENTERING DRY BULB, °F POWER 83 80 77 74 71 68 CAP. MBH INPUT2 kW 86 35.2 41.7 44.7 42.4 35.2 41.7 44.7 42.4 30.0 35.7 41.2 39.8 27.3 32.6 37.7 37.9 24.6 29.5 34.2 36.0 30.7 37.2 43.6 42.4 30.7 37.2 43.6 42.4 26.5 32.2 37.7 39.8 24.3 29.6 34.7 37.0 22.1 26.9 31.6 34.2 26.2 32.8 39.1 42.4 26.2 32.8 39.1 42.4 23.0 28.7 34.2 37.3 21.2 26.5 31.6 34.5 19.5 24.4 29.1 31.7 21.8 28.3 34.6 37.9 21.8 28.3 34.6 37.9 19.5 25.2 30.7 33.8 18.2 23.5 28.6 31.4 16.9 21.8 26.5 29.1 17.3 23.8 30.1 33.4 17.3 23.8 30.1 33.4 21.7 27.2 30.3 20.5 25.6 28.4 14.4 19.2 23.9 26.5 19.4 25.7 29.0 19.4 25.7 29.0 16.0 18.2 23.7 26.8 15.2 17.4 22.5 25.4 16.7 21.4 24.0 14.9 21.2 24.5 14.9 21.2 24.5 14.7 20.2 23-3 14.4 19.5 22.3 14.1 18.8 21.4 51.5 45.8 41.2 39.9 50.0 44.5 40.0 38.8 48.6 43.2 38.9 37.6 46.4 41.2 37.1 35.9 44.2 39.3 35.4 34.2 3.44 3.35 3.30 3.35 3.41 3.32 3.27 3.32 3.38 3.29 3.23 3.29 3.36 3.27 3.21 3.27 3.34 3.25 3.20 3.25 86 83 80 77 74 71 68 34.1 40.2 41.2 39.9 31.5 37.2 40.0 38.8 28.9 34.2 38.9 37.6 26.2 31.1 36.2 35.9 23.6 28.0 33.5 34.2 29.7 35.7 41.2 39.9 27.5 33.2 39.2 38.8 25.4 30.7 37.2 37.6 23.2 28.1 34.1 34.9 21.0 25.4 30.9 32.1 25.2 31.3 38.8 39.9 23.6 29.2 36.3 37.5 21.9 27.2 33.7 35.1 20.2 25.0 31.1 32.3 18.4 22.9 28.4 29.5 20.7 26.8 34.3 35.4 19.6 25.3 32.3 33.5 18.4 23.7 30.2 31.6 17.2 22.0 28.0 29.3 15.9 20.3 25.8 27.0 16.2 22.3 29.8 31.0 15.6 21.3 28.3 29.6 14.9 20.2 26.7 28.1 14.1 19.0 25.0 26.3 13.3 17.7 23.2 24.4 17.8 25.3 26.5 17.3 24.3 25.6 16.7 23.2 24.6 16.0 22.0 23.2 15.2 20.7 21.8 13.4 20.9 22.0 13.3 20.3 21.6 13.2 19.8 21.1 12.9 18.9 20.2 12.6 18.1 19.3 TEMPERATURE OF AIR ON CONDENSER COIL AIR ON EVAPORATOR COIL 105°F TOTAL 1 CFM 1500 1350 1200 1050 900 POWER CAP. MBH INPUT2 kW WB °F 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 47.6 42.5 38.0 37.4 46.5 41.6 37.1 36.5 45.4 40.6 36.2 35.7 43.2 38.7 34.5 34.0 41.1 36.7 32.8 32.3 3.65 3.56 3.49 3.54 3.62 3.53 3.46 3.52 3.60 3.51 3.44 3.49 3.57 3.48 3.41 3.47 3.54 3.45 3.39 3.44 115°F SENSIBLE CAPACITY1 ENTERING DRY BULB, °F TOTAL 1 SENSIBLE CAPACITY1 ENTERING DRY BULB, °F POWER 83 80 77 74 71 68 CAP. MBH INPUT2 kW 86 32.3 39.0 38.0 37.4 29.7 36.0 37.1 36.5 27.2 33.0 36.2 35.7 24.6 29.9 33.9 34.0 22.0 26.8 31.5 32.3 27.8 34.5 38.0 37.4 25.8 32.0 36.6 36.5 23.7 29.5 35.2 35.7 21.6 26.9 32.1 32.9 19.4 24.2 28.9 30.1 23.3 30.0 36.6 37.4 21.8 28.0 34.1 35.2 20.2 26.0 31.7 33.0 18.5 23.8 29.0 30.3 16.8 21.7 26.4 27.5 18.9 25.6 32.1 32.9 17.8 24.0 30.1 31.2 16.7 22.5 28.2 29.5 20.8 26.0 27.2 14.3 19.1 23.8 24.9 14.4 21.1 27.6 28.5 13.8 20.1 26.1 27.2 12.2 19.0 24.7 26.0 12.5 17.8 23.0 24.2 11.7 16.5 21.2 22.4 16.6 23.1 24.0 16.1 22.2 23.3 15.5 21.2 22.5 14.7 19.9 21.2 14.0 18.7 19.8 12.1 18.7 19.5 12.1 18.2 19.3 12.0 17.7 19.0 11.7 16.9 18.1 11.4 16.1 17.2 43.6 39.3 34.8 34.9 42.9 38.6 34.2 34.3 42.2 37.9 33.6 33.7 40.1 36.1 32.0 32.1 38.0 34.2 30.3 30.4 3.85 3.76 3.67 3.73 3.83 3.74 3.66 3.72 3.82 3.73 3.64 3.70 3.78 3.69 3.61 3.67 3.75 3.66 3.58 3.64 86 83 80 77 74 71 68 30.4 37.8 34.8 34.9 28.0 34.8 34.2 34.3 25.5 31.8 33.6 33.7 22.9 28.7 31.6 32.1 20.4 25.6 29.5 30.4 26.0 33.3 34.8 34.9 24.0 30.8 34.0 34.3 22.0 28.3 33.1 33.7 19.9 25.7 30.0 30.9 17.8 23.0 26.9 28.0 21.5 28.8 34.4 34.9 20.0 26.8 32.0 32.9 18.5 24.8 29.6 30.9 16.9 22.6 27.0 28.2 15.2 20.4 24.4 25.4 17.0 24.3 29.9 30.5 16.0 22.8 28.0 28.9 15.0 21.3 26.1 27.4 13.8 19.6 23.9 25.1 12.7 17.9 21.8 22.9 12.5 19.9 25.4 26.0 12.0 18.8 24.0 24.9 11.5 17.8 22.6 23.9 10.8 16.6 20.9 22.1 10.1 15.3 19.2 20.3 15.4 20.9 21.5 14.9 20.0 21.0 14.3 19.1 20.4 13.5 17.9 19.1 12.7 16.7 17.7 10.9 16.5 17.0 10.9 16.0 17.0 10.8 15.6 16.9 10.5 14.9 16.0 10.2 14.1 15.2 1. These capacities are gross ratings. For net capacity, determine the kW of the supply air blower from the SUPPLY AIR BLOWER PERFORMANCE Tables, multiply this value by 3.415 MBH/kW to determine the motor heat, and deduct this heat from the gross capacity of the unit. 2. These ratings include the compressor and the condenser fan motors but not the supply air blower motor. The total condenser fan motor power input is 0.36kW. Refer to SUPPLY AIR BLOWER PERFORMANCE Tables for the kW of the supply air blower motor. NOMINAL RATING 16 Unitary Products Group 036-21506-004-A-1105 TABLE 6: DH048 COOLING CAPACITIES (4 TON) TEMPERATURE OF AIR ON CONDENSER COIL AIR ON EVAPORATOR COIL TOTAL INPUT2 kW CFM WB °F CAP.1 MBH 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 59 53 47 47 58 53 47 46 57 52 46 45 54 49 43 43 51 46 41 40 3.3 3.2 3.2 3.1 3.3 3.2 3.2 3.1 3.3 3.2 3.2 3.1 3.2 3.1 3.1 3.1 3.2 3.1 3.1 3.0 2000 1800 1600 1400 1200 85°F 95°F SENSIBLE CAPACITY1 ENTERING DRY BULB, °F POWER TOTAL 86 83 80 77 74 71 68 CAP.1 MBH 46 53 47 47 42 50 47 46 39 47 46 45 35 43 43 43 32 39 41 40 40 49 47 47 37 46 47 46 34 42 46 45 31 39 43 43 29 35 41 40 34 43 47 47 32 41 46 46 30 38 45 45 27 35 42 41 25 32 38 38 28 38 42 41 27 35 41 41 25 33 41 40 23 31 38 37 22 28 35 34 23 32 36 35 22 30 36 35 21 29 36 36 19 27 34 33 18 25 31 31 26 30 29 25 31 30 24 32 31 23 30 29 21 28 27 21 25 24 20 26 25 19 27 27 19 26 25 18 24 24 55 49 44 43 54 48 43 42 53 48 42 41 51 45 40 39 48 42 38 37 SENSIBLE CAPACITY1 ENTERING DRY BULB, °F POWER INPUT2 kW 3.5 3.4 3.4 3.3 3.5 3.4 3.4 3.3 3.5 3.4 3.4 3.3 3.5 3.4 3.4 3.3 3.5 3.5 3.4 3.4 86 83 80 77 74 71 68 43 49 44 43 40 47 43 42 37 45 42 41 34 41 40 39 30 37 38 37 37 47 44 43 35 44 43 42 33 41 42 41 30 37 40 39 27 34 38 37 32 41 44 43 30 39 43 42 28 36 43 41 26 33 40 38 23 30 36 35 26 35 38 37 25 33 38 37 23 32 39 37 22 29 36 34 20 27 33 31 20 30 32 31 20 28 33 32 19 27 34 32 17 25 32 30 16 23 29 28 24 26 26 23 28 27 22 30 28 21 28 26 20 26 24 - - - - - TEMPERATURE OF AIR ON CONDENSER COIL AIR ON EVAPORATOR COIL 105°F TOTAL 1 CFM 1500 1350 1200 1050 900 POWER CAP. MBH INPUT2 kW WB °F 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 50 45 39 39 50 44 39 38 49 44 39 38 47 42 37 36 44 40 35 34 3.8 3.7 3.6 3.6 3.8 3.7 3.6 3.6 3.8 3.7 3.6 3.6 3.8 3.7 3.6 3.5 3.7 3.7 3.6 3.5 115°F SENSIBLE CAPACITY1 ENTERING DRY BULB, °F TOTAL 1 SENSIBLE CAPACITY1 ENTERING DRY BULB, °F POWER 83 80 77 74 71 68 CAP. MBH INPUT2 kW 86 41 45 39 39 38 44 39 38 35 43 39 38 32 39 37 36 29 36 35 34 35 44 39 39 33 41 39 38 31 39 39 38 28 35 37 36 25 32 35 34 30 39 39 39 28 36 40 38 26 34 41 38 24 31 38 35 22 29 34 32 24 33 34 33 23 31 35 33 21 30 37 33 20 27 33 31 18 25 30 28 18 27 28 27 18 26 30 28 17 25 32 29 16 23 29 27 15 21 27 25 22 22 22 21 25 23 20 27 24 19 25 23 18 23 21 16 17 16 16 20 18 16 23 19 15 21 18 14 20 18 45 40 35 35 45 40 35 34 45 40 35 34 43 38 33 33 41 36 32 31 4.0 4.0 3.8 3.8 4.0 4.0 3.9 3.8 4.1 4.1 3.9 3.8 4.0 4.0 3.8 3.7 3.9 3.9 3.8 3.7 86 83 80 77 74 71 68 39 40 35 35 36 40 35 34 33 40 35 34 30 37 33 33 27 34 32 31 33 40 35 35 31 39 35 34 29 37 35 34 26 34 33 33 24 30 32 31 28 37 35 35 26 34 37 34 24 32 39 34 22 29 35 31 20 27 32 29 22 31 30 29 21 29 32 29 20 27 34 30 18 25 31 27 17 23 28 25 16 25 24 23 16 24 27 24 15 23 30 25 14 21 27 23 13 20 25 22 20 18 18 19 22 19 18 25 20 17 23 19 16 21 18 - - - - - 1. These capacities are gross ratings. For net capacity, determine the kW of the supply air blower from the SUPPLY AIR BLOWER PERFORMANCE Tables, multiply this value by 3.415 MBH/kW to determine the motor heat, and deduct this heat from the gross capacity of the unit. 2. These ratings include the compressor and the condenser fan motors but not the supply air blower motor. The total condenser fan motor power input is 0.36kW. Refer to SUPPLY AIR BLOWER PERFORMANCE Tables for the kW of the supply air blower motor. NOMINAL RATING Unitary Products Group 17 036-21506-004-A-1105 TABLE 7: DH060 COOLING CAPACITIES (5 TON) TEMPERATURE OF AIR ON CONDENSER COIL AIR ON EVAPORATOR COIL TOTAL INPUT2 kW CFM WB °F CAP.1 MBH 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 82 70 67 66 78 67 64 63 75 64 61 60 72 62 59 58 69 59 56 55 4.3 4.2 4.0 4.0 4.3 4.2 4.0 4.0 4.3 4.2 4.0 4.0 4.3 4.2 4.0 4.0 4.2 4.1 4.0 4.0 2500 2250 2000 1750 1500 85°F 95°F SENSIBLE CAPACITY1 ENTERING DRY BULB, °F POWER TOTAL 86 83 80 77 74 71 68 CAP.1 MBH 56 67 67 66 53 63 64 63 49 58 61 60 44 53 59 58 40 48 56 55 50 61 67 66 47 57 64 63 43 53 61 60 40 49 57 57 36 44 53 54 43 54 66 66 41 51 62 63 38 48 58 59 35 44 53 55 32 40 49 50 37 48 59 59 35 45 56 57 33 42 52 54 30 39 48 50 28 36 44 46 30 41 52 52 29 39 50 51 27 37 47 49 25 34 44 45 24 32 40 42 34 46 46 33 44 45 32 42 43 30 39 40 28 36 37 28 39 39 27 38 39 26 36 38 25 34 36 23 32 33 76 65 62 61 73 62 60 58 70 60 57 56 67 58 55 54 65 56 53 52 SENSIBLE CAPACITY1 ENTERING DRY BULB, °F POWER INPUT2 kW 4.6 4.5 4.5 4.4 4.6 4.5 4.4 4.4 4.6 4.5 4.4 4.4 4.6 4.5 4.4 4.4 4.6 4.5 4.4 4.4 86 83 80 77 74 71 68 54 65 62 61 50 60 60 58 46 56 57 56 43 51 55 54 39 46 53 52 48 58 62 61 44 54 60 58 41 50 57 56 38 46 54 54 34 42 51 51 41 51 62 61 38 48 59 58 36 45 55 56 33 41 51 51 30 38 47 47 34 45 55 54 32 42 53 52 30 39 50 50 28 37 46 47 26 34 43 43 28 38 49 47 26 36 47 46 25 34 45 45 24 32 42 42 22 30 39 39 31 42 41 30 41 40 29 39 39 27 37 37 26 35 35 25 35 34 24 35 34 23 34 34 22 32 32 21 30 30 TEMPERATURE OF AIR ON CONDENSER COIL AIR ON EVAPORATOR COIL 105°F TOTAL 1 CFM 2500 2250 2000 1750 1500 POWER CAP. MBH INPUT2 kW WB °F 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 68 60 56 55 67 58 55 54 65 57 53 52 62 54 51 50 59 52 48 47 5.0 4.8 4.8 4.7 4.9 4.8 4.7 4.7 4.9 4.8 4.7 4.7 4.9 4.8 4.7 4.6 4.9 4.7 4.7 4.6 115°F SENSIBLE CAPACITY1 ENTERING DRY BULB, °F TOTAL 1 SENSIBLE CAPACITY1 ENTERING DRY BULB, °F POWER 83 80 77 74 71 68 CAP. MBH INPUT2 kW 86 51 60 56 55 48 57 55 54 44 54 53 52 40 49 51 50 36 44 48 47 44 55 56 55 42 52 55 54 39 48 53 52 35 44 50 50 32 40 47 47 38 49 56 55 36 46 54 53 33 43 52 52 31 40 48 48 28 36 43 43 31 42 49 48 30 40 48 47 28 38 46 46 26 35 43 43 24 32 39 39 25 35 43 42 24 34 42 41 23 32 41 41 21 30 38 38 20 28 35 35 29 36 35 28 36 35 27 36 36 25 33 33 24 31 31 22 29 28 22 30 29 22 30 30 21 29 29 20 27 27 61 55 50 49 60 54 49 49 60 54 49 48 56 51 46 46 53 48 43 43 5.3 5.1 5.1 5.0 5.3 5.1 5.0 5.0 5.2 5.1 5.0 5.0 5.2 5.0 5.0 4.9 5.2 5.0 4.9 4.9 86 83 80 77 74 71 68 48 55 50 49 45 53 49 49 42 52 49 48 38 47 46 46 34 43 43 43 41 53 50 49 39 50 49 49 36 47 49 48 33 42 46 46 30 38 43 43 35 46 50 49 33 44 49 49 31 41 48 48 28 38 44 44 26 34 40 40 28 39 43 43 27 38 43 43 26 36 43 42 24 33 39 39 22 30 36 36 21 33 37 36 21 32 37 37 20 30 37 37 19 28 34 34 18 26 32 31 26 30 29 26 31 31 25 32 32 23 30 29 22 27 27 20 23 23 20 25 25 20 26 26 19 25 25 18 23 23 1. These capacities are gross ratings. For net capacity, determine the kW of the supply air blower from the SUPPLY AIR BLOWER PERFORMANCE Tables, multiply this value by 3.415 MBH/kW to determine the motor heat, and deduct this heat from the gross capacity of the unit. 2. These ratings include the compressor and the condenser fan motors but not the supply air blower motor. The total condenser fan motor power input is 0.36kW. Refer to SUPPLY AIR BLOWER PERFORMANCE Tables for the kW of the supply air blower motor. NOMINAL RATING 18 Unitary Products Group 036-21506-004-A-1105 TABLE 8: SUPPLY AIR BLOWER PERFORMANCE (3 TON BELT DRIVE) - SIDE DUCT APPLICATION UNIT TONNAGE 3 1 UNIT TONNAGE 3 1 AVAILABLE EXTERNAL STATIC PRESSURE-IWG 2 0.60 0.40 0.50 AIR FLOW CFM RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS 2000 843 860 880 925 919 1005 956 1065 993 1145 1030 1195 1067 1235 1900 817 775 854 850 893 920 930 995 970 1065 1008 1125 1046 1170 1800 790 700 828 760 867 840 906 905 944 980 985 1040 1025 1100 1700 - - 802 670 840 745 881 815 920 900 961 970 1001 1030 1600 - - - - 818 665 858 740 898 820 940 890 980 950 1500 - - - - - - 842 695 882 755 922 835 962 895 1400 - - - - - - 833 650 867 705 904 765 942 820 1300 - - - - - - - - 858 665 893 725 932 785 1200 - - - - - - - - 847 640 880 680 916 730 0.20 0.30 0.70 AVAILABLE EXTERNAL STATIC PRESSURE-IWG 2 1.10 1.20 1.30 0.80 AIR FLOW CFM RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS 2000 1103 1270 - - - - - - - - - - - - 1900 1085 1210 - - - - - - - - - - - - 1800 1064 1145 1102 1180 - - - - - - - - - - 1700 1040 1075 1081 1115 1121 1140 - - - - - - - - 1600 1020 1005 1060 1050 1100 1085 - - - - - - - - 1500 1003 945 1044 995 1086 1035 - - - - - - - - 1400 982 880 1024 920 1067 965 1107 1000 - - - - - - 1300 970 835 1010 870 1053 920 1099 960 - - - - - - 1200 953 780 992 815 1034 855 1080 905 - - - - - - 0.90 1.00 1.40 1.50 1. For 208 Volts multiply values by 0.95. 2. Includes allowances for a wet evaporator coil, 1” filters, and the heat exchangers. Refer to STATIC RESISTANCE Table for resistance values on applications other than gas / electric units with side duct airflows. Unitary Products Group 19 036-21506-004-A-1105 TABLE 9: SUPPLY AIR BLOWER PERFORMANCE (4 TON BELT DRIVE) - SIDE DUCT APPLICATION UNIT TONNAGE 4 1 UNIT TONNAGE 4 1 AVAILABLE EXTERNAL STATIC PRESSURE-IWG 2 0.60 0.40 0.50 AIR FLOW CFM RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS 2000 843 860 880 925 919 1005 956 1065 993 1145 1030 1195 1067 1235 1900 817 775 854 850 893 920 930 995 970 1065 1008 1125 1046 1170 1800 790 700 828 760 867 840 906 905 944 980 985 1040 1025 1100 1700 - - 802 670 840 745 881 815 920 900 961 970 1001 1030 1600 - - - - 818 665 858 740 898 820 940 890 980 950 1500 - - - - - - 842 695 882 755 922 835 962 895 1400 - - - - - - 833 650 867 705 904 765 942 820 1300 - - - - - - - - 858 665 893 725 932 785 1200 - - - - - - - - 847 640 880 680 916 730 0.20 0.30 0.70 AVAILABLE EXTERNAL STATIC PRESSURE-IWG 2 1.10 1.20 1.30 0.80 AIR FLOW CFM RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS 2000 1103 1270 - - - - - - - - - - - - 1900 1085 1210 - - - - - - - - - - - - 1800 1064 1145 1102 1180 - - - - - - - - - - 1700 1040 1075 1081 1115 1121 1140 - - - - - - - - 1600 1020 1005 1060 1050 1100 1085 - - - - - - - - 1500 1003 945 1044 995 1086 1035 - - - - - - - - 1400 982 880 1024 920 1067 965 1107 1000 - - - - - - 1300 970 835 1010 870 1053 920 1099 960 - - - - - - 1200 953 780 992 815 1034 855 1080 905 - - - - - - 0.90 1.00 1.40 1.50 1. Models shown at 230/460 Volts with side duct connections. 2. Includes allowances for a wet evaporator coil, 1” filters, and the heat exchangers. Refer to STATIC RESISTANCE Table for resistance values on applications other than gas / electric units with side duct airflows. 20 Unitary Products Group 036-21506-004-A-1105 TABLE 10: SUPPLY AIR BLOWER PERFORMANCE (5 TON BELT DRIVE) - SIDE DUCT APPLICATION UNIT TONNAGE 5 1 UNIT TONNAGE 5 1 AVAILABLE EXTERNAL STATIC PRESSURE-IWG 2 0.60 0.40 0.50 AIR FLOW CFM RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS 2500 1059 1560 1077 1590 1095 1630 1114 1650 1134 1660 1158 1685 1181 1720 2400 1032 1405 1054 1470 1074 1525 1094 1560 1116 1595 1140 1620 1167 1640 2300 1005 1260 1024 1275 1049 1370 1069 1440 1090 1475 1116 1505 1142 1535 2200 980 1160 1002 1170 1022 1190 1044 1250 1066 1350 1090 1410 1117 1440 2100 930 1060 957 1070 983 1080 1010 1100 1039 1160 1064 1260 1092 1340 2000 877 950 908 975 941 1000 976 1020 1009 1050 1040 1100 1070 1225 1900 - - - - 894 885 940 940 980 980 1014 1020 1047 1095 1800 - - - - 855 815 903 860 950 905 988 940 1022 970 1700 - - - - - - 884 815 925 850 964 880 1001 910 1600 - - - - - - 864 770 908 805 948 835 987 870 1500 - - - - - - - - 882 740 926 780 965 830 0.20 0.30 0.70 AVAILABLE EXTERNAL STATIC PRESSURE-IWG 2 1.10 1.20 1.30 0.80 AIR FLOW CFM RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM 2500 - - - - - - - - - - - - - - 2400 1193 1665 - - - - - - - - - - - - 2300 1170 1580 1202 1620 - - - - - - - - - - 2200 1148 1480 1180 1530 - - - - - - - - - - 2100 1121 1385 1155 1425 1190 1475 - - - - - - - - 2000 1100 1285 1133 1340 1169 1385 1205 1445 - - - - - - 1900 1079 1180 1110 1240 1143 1280 1178 1330 1222 1375 - - - - 1800 1058 1060 1090 1135 1122 1190 1158 1240 1196 1295 - - - - 1700 1035 960 1071 1030 1103 1100 1134 1140 1164 1175 1197 1205 - - 1600 1020 900 1056 965 1088 1035 1118 1065 1145 1105 1170 1130 1198 1150 1500 1004 860 1038 880 1070 925 1101 980 1130 1045 1158 1075 1184 1110 0.90 1.00 1.40 1.50 WATTS 1. Models shown at 230/460 Volts with side duct connections. 2. Includes allowances for a wet evaporator coil, 1” filters, and the heat exchangers. Refer to STATIC RESISTANCE Table for resistance values on applications other than gas / electric units with side duct airflows. TABLE 11: BELT DRIVE BLOWER MOTOR AND DRIVE DATA MOTOR1 ADJUSTABLE MOTOR PULLEY BELT (NOTCHED) FIXED BLOWER PULLEY MODEL SIZE BLOWER RANGE (RPM) HP FRAME DESIGNATION OUTSIDE DIA. (IN.) PITCH DIA. (IN.) BORE (IN.) DESIGNATION OUTSIDE DIA. (IN.) PITCH DIA. (IN.) BORE (IN.) DESIGNATION PITCH LENGTH (IN.) QTY. 3 TON 790/1120 1 1/2 56 1VL40 2.7-3.7 2.4-3.4 5/8 AK61 5.9 5.7 1 A36 37.3 1 4 TON 790/1120 1 1/2 56 1VL40 2.7-3.7 2.4-3.4 5/8 AK61 5.9 5.7 1 A36 37.3 1 5 TON 850/1220 1 1/2 56 1VL40 2.7-3.7 2.4-3.4 5/8 AK56 5.4 5.2 1 A36 37.3 1 1. All motors have solid bases and are inherently protected. these motors can be selected to operate into their service factor because they are located in the moving air, upstream of any heating device. Unitary Products Group 21 036-21506-004-A-1105 TABLE 12: STATIC RESISTANCES RESISTANCE, IWG DESCRIPTION CFM 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 0.07 0.08 0.09 0.11 0.13 0.15 0.17 0.20 0.23 0.26 0.30 7-15KW 0.04 0.05 0.06 0.07 0.08 0.10 0.12 0.14 0.16 0.19 0.22 20-30KW 0.06 0.07 0.08 0.09 0.11 0.13 0.15 0.17 0.20 0.23 0.26 BOTTOM DUCT CONNECTIONS1 0.06 0.07 0.08 0.09 0.10 0.11 0.12 0.14 0.16 0.19 0.22 COOLING ONLY2 0.08 0.10 0.12 0.14 0.16 0.18 0.20 0.23 0.26 0.29 0.32 ECONOMIZER1 3 ELECTRIC HEATERS1 1. Deduct these resistance values from the available external static pressure shown in SUPPLY AIR BLOWER PERFORMANCE Tables. 2. Add these resistance values to the available static resistance values on SUPPLY AIR BLOWER PERFORMANCE Tables. 3. The pressure through the economizer is greater for 100% outdoor air than for 100% return air. If the resistance of the return air duct system is less than 0.25 IWG, the unit will deliver less CFM during full economizer operation. TABLE 13: ELECTRIC HEATER CFM LIMITATIONS MINIMUM SUPPLY AIR CFM UNITMODEL SIZE NOMINAL TONS 3 4 5 22 VOLTAGE HEATER SIZE NOMINAL KW 5 7 10 15 20 30 208/230-3-60 1100 1100 1200 1200 1300 - 460-3-60 - 1100 1200 1200 1300 - 575-3-60 - - 1200 1200 1300 - 208/230-3-60 1300 1300 1300 1300 1300 - 460-3-60 - 1300 1300 1300 1300 - 575-3-60 - - 1300 1300 1400 - 208/230-3-60 1600 1600 1600 1600 1600 1600 460-3-60 - 1600 1600 1600 1600 1600 575-3-60 - - 1600 1600 1600 1800 Unitary Products Group 036-21506-004-A-1105 TABLE 14: ELECT DATA - DH036, 048 & 060 BELT DRIVE WITHOUT POWR’D CONVENIENCE OUTLET 0RGHO 7RQQDJH &RPSUHVVRUV 9ROWDJH 5/$ (DFK /5$ (DFK 2')DQ ,'%ORZHU &RQY 0RWRU 0RWRU 2XWOHW )/$ )/$ $PSV (OHFWULF+HDWHU 0RGHO1R +HDWHU N: +HDWHU $PSV 0LQLPXP &LUFXLW $PSDFLW\ $PSV 0D[)XVH %5.5 6L]H $PSV 121( &( &( &( &( &( 121( &( &( &( &( &( 121( &( &( &( &( 121( &( &( &( &( &( 121( &( &( &( &( &( 121( &( &( &( &( 121( &( &( &( 121( &( &( &( &( &( &( 121( &( &( &( &( &( &( 121( &( &( &( &( &( 121( &( &( &( &( +$&57\SHSHU1(& 7KHVHHOHFWULFKHDWHUV'2127LQFOXGHDIXVHER[,IDIXVHER[LVUHTXLUHGWRPHHWDORFDOFRGHLH&KLFDJRWKHIXVHEORFNDFFHVVRULHV )%DQG)%DUHDYDLODEOHIRUILHOGLQVWDOODWLRQ Unitary Products Group 23 036-21506-004-A-1105 TABLE 15: ELECT DATA - DH036, 048 & 060 BELT DRIVE WITH POWR’D CONVENIENCE OUTLET -ODEL 4ONNAGE #OMPRESSORS 6OLTAGE 2,! %ACH ,2! %ACH /$&AN -OTOR &,! )$"LOWER -OTOR &,! #ONV /UTLET !MPS %LECTRIC(EATER -ODEL.O 121( &( &( &( &( &( 121( &( &( &( &( &( 121( &( &( &( &( 121( &( &( &( &( &( 121( &( &( &( &( &( 121( &( &( &( &( 121( &( &( &( 121( &( &( &( &( &( &( 121( &( &( &( &( &( &( 121( &( &( &( &( &( 121( &( &( &( &( (EATER K7 (EATER !MPS -INIMUM #IRCUIT !MPACITY !MPS -AX&USE "2+2 3IZE !MPS +$&57\SHSHU1(& 7KHVHHOHFWULFKHDWHUV'2127LQFOXGHDIXVHER[,IDIXVHER[LVUHTXLUHGWRPHHWDORFDOFRGHLH&KLFDJRWKHIXVHEORFNDFFHVVRULHV )%DQG)%DUHDYDLODEOHIRUILHOGLQVWDOODWLRQ 24 Unitary Products Group 036-21506-004-A-1105 TABLE 16: PHYSICAL DATA DH MODELS EVAPORATOR BLOWER EVAPORATOR COIL CONDENSER FANS CONDENSER COILS COMPRESSOR (Qty. Per Unit) AIR FILTERS CHARGE 036 048 060 Centrifugal Blower (Dia. x Wd. in.) 12 X 10 12 X 10 12 X 10 Fan Motor HP (Belt Drive) 1 1/2 1 1/2 1 1/2 Rows Deep 4 4 4 Fins Per Inch 13 13 13 Face Area (Sq. Ft.) 4.3 5.1 5.1 Propeller Dia. (in.) 24 24 24 Fan Motor Hp 1/2 1/2 1/2 4200 Nom. CFM 4500 4200 Rows Deep 2 2 2 Fins Per Inch 18 18 18 Face Area (Sq. Ft.) 17.1 17.1 17.1 Recip. Type 1 1 1 Quantity Per Unit (15” X 20” X 1” or 2“) 2 2 2 Quantity Per Unit (14” X 25” X 1” or 2“) 1 1 1 Total Face Area (sq. ft.) 6.3 6.3 6.3 Refrigerant 22 (lbs./oz.) 10/8 10/4 10/14 TABLE 17: ELECTRIC HEAT CORRECTION FACTORS NOMINAL VOLTAGE VOLTAGE kW CAP. MULTIPLIER MAX. 208/230-3-60 187 253 0.92 460-3-60 414 506 0.92 575-3-60 540 630 208 1.00 240 230 0.92 600 460 575 VOLTAGE POWER SUPPLY MIN. 208 480 TABLE 18: VOLTAGE LIMITATIONS1 1. Utilization Range “A” in accordance with ARI Standard 110. Unitary Products Group 25 036-21506-004-A-1105 TYPICAL POWER WIRING REFER TO THE ELECTRICAL DATA TABLES TO SIZE THE DISCONNECT SWITCH, OVERCURRENT PROTECTION AND WIRING. TYPICAL CONTROL WIRING COOLING / HEATING (24 VOLT THERMOSTAT) COOLING ONLY (24 VOLT THERMOSTAT) THERMOSTAT 1 TERMINALS THERMOSTAT1 UNIT TERMINAL TERMINALS STRIP TB1 ADD JUMPER R RV UNIT TERMINAL STRIP TB1 RC R Y Y1 24 VOLT TRANSFORMER Y1 YC RH 24 VOLT TRANSFORMER Y2 Y2 W W1 G GF W2 C 1 G C 24 VOLT THERMOSTAT 2TH07701024. TO CONTROL THE ECONOMIZER ON SECOND STAGE COOLING, USE THE THERMOSTAT 2TH0401224. 1 COOLING / HEATING (ELECTRONIC THERMOSTAT) MULTI STAGE THERMOSTAT1 TERMINALS ADD JUMPER RC UNIT TERMINAL STRIP TB1 RH R Y1 Y1 2 Y2 W1 4 ADD JUMPER C LED 1 X NOT USED RH ADD JUMPER OCC A1 T TO REMOTE SENSOR 2TH040702224 IF USED 2 SECOND STAGE COOLING IS NOT REQUIRED ON UNITS LESS ECONOMIZER. 3 SECOND STAGE HEATING IS ONLY REQUIRED ON UNITS WITH A TWO STAGE ELECTRIC HEATER OR 2 STAGE GAS HEAT. RC R Y Y1 W W1 G G 24 VOLT TRANSFORMER A2 ELECTRONIC PROGRAMMABLE THERMOSTAT 2ET04700224 (INCLUDES SUBBASE). UNIT TERMINAL STRIP TB1 C 4 1 4 THERMOSTAT1 TERMINALS 24 VOLT TRANSFORMER W2 G T 1 ELECTRONIC PROGRAMMABLE THERMOSTAT 2ET07701024 (INCLUDES SUBBASE). TO CONTROL THE ECONOMIZER ON SECOND STAGE COOLING, USE THERMOSTAT 2TH04700224. REMOVE JUMPER J2 FROM TERMINALS 4 AND 9 ON JUMPER PLUG CONNECTOR P6 ON UNITS WITH ECONOMIZER. TERMINALS A1 AND A2 PROVIDE A RELAY OUT-PUT TO CLOSE THE OUTDOOR ECONOMIZER DAMPERS WHEN THE THERMOSTAT SWITCHES TO THE SET-BACK POSITION. FIGURE 2 - 26 3 B COM COOLING / HEATING (ELECTRONIC THERMOSTAT) SINGLE STAGE Y2 G LED 2 24 VOLT THERMOSTAT 2ET07701024. TO CONTROL THE ECONOMIZER ON THE SECOND STAGE COOLING OR TO HAVE AN ELECTRIC HEAT ACCESSORY WITH TWO STAGES OF HEAT, USE THERMOSTAT 2TH0471024. W1 W2 G TYPICAL FIELD POWER & CONTROL WIRING Unitary Products Group 036-21506-004-A-1105 FIGURE 3 - UNIT DIMENSIONS (3 - 5 TON COOLING ONLY/ELECTRIC HEAT) FRONT VIEW FIGURE 4 - UNIT DIMENSIONS (3 - 5 TON COOLING/GAS HEAT) FRONT VIEW Unitary Products Group 27 036-21506-004-A-1105 DETAIL “A” FIGURE 5 - UNIT WITH ECONOMIZER RAINHOOD DETAIL “B” FIGURE 6 - 28 UNIT WITH FIXED OUTDOOR AIR/MOTORIZED DAMPER RAINHOOD Unitary Products Group 036-21506-004-A-1105 FIGURE 7 - UNIT DIMENSIONS (REAR VIEW) TABLE 20: MINIMUM CLEARANCES FILTER ACCESS BLOWER MOTOR ACCESS LOCATION CLEARANCE Front 24” (Cooling/Electric Heat) 32” (Gas Heat) Rear 12” (Less Economizer) 36” (With Economizer or Fixed Air/Motorized Damper) Left Side (Filter Access) 24” (Less Economizer) 36” (With Economizer) Right Side (Cond. Coil) 24” DOT PLUGS FIELD-SUPPLIED DISCONNECT SWITCH LOCATION MOUNTING BRACKET FOR DICONNECT SWITCH (Shipped attached to the blower housing inside the blower compartment) Below Unit A,B WIRING ENTRY (See Detail “B”) 0” 2 72” (For Condenser Air Discharge) Above Unit CONTROL BOX ACCESS DISCONNECT SWITCH LOCATION AND MOTOR ACCESS PANEL FOR UNIT WITH “BELT-DRIVE” OPTION FIGURE 8 - 1 DISCONNECT/BLOWER ACCESS LOCATION 1. Units may be installed on combustible floors made from wood or class A, B, or C roof covering material. 2. Units must be installed outdoors. Overhanging structures or shrubs should not obstruct condenser air discharge outlet. TABLE 19: UTILITIES ENTRY HOLE OPENING SIZE (DIA.) USED FOR A 7/8” KO1 Control Wiring2 B 2” KO1 Power Wiring C 1-5/8” KO Gas Piping (Front) D 1-1/2” KO Gas Piping (Bottom) Side Bottom Side Bottom 1. Opening in the bottom to the unit can be located by the side in the insulation. 2. Do not remove the 2” knockout ring. Unitary Products Group 29 036-21506-004-A-1105 FIGURE 9 - 30 TYPICAL APPLICATIONS Unitary Products Group 036-21506-004-A-1105 BACK OF UNIT A 447/8 BACK OF UNIT A 447/8 821/4 821/4 D B F X X B APPROXIMATE CENTER OF GRAVITY CONDENSER COIL END OF UNIT C Y FRONT OF UNIT C E APPROXIMATE CENTER OF GRAVITY CONDENSER COIL END OF UNIT D Y FRONT OF UNIT FIGURE 10 - FOUR AND SIX POINT LOADING TABLE 21: DH 4 AND 6 POINT LOADS WEIGHT DISTRIBUTION UNIT TOTAL 4-Point Loading (lb) 6-Point Loading (lb) A B C D A B C D E F 123 157 160 84 83 82 104 105 107 DH036 Cooling/ Electric 565 125 DH036N04 605 134 132 168 171 90 89 88 112 113 114 DH036D06 615 137 134 171 174 91 90 89 113 115 116 DH036N08 625 139 136 173 177 93 92 91 115 117 118 DH036D10 635 141 138 176 179 94 93 92 117 119 120 DH048 Cooling/ Electric 610 135 133 169 172 91 89 88 112 114 115 DH048(D,N)06 660 147 144 183 186 98 97 96 122 123 125 DH048(D,N)10 680 151 148 189 192 101 100 99 125 127 128 DH060 Cooling/ Electric 645 143 141 179 182 96 95 93 119 120 122 DH060D06 695 154 152 193 196 103 102 101 128 130 131 DH060N08 705 157 154 196 199 105 103 102 130 132 133 DH060(D,N)10 715 159 156 198 202 106 105 104 132 133 135 TABLE 22: CENTER OF GRAVITY DIMENSION 3 - 5 TON X 40-¾” Y 19-¾” Unitary Products Group 31 036-21506-004-A-1105 TABLE 23: OPERATING WEIGHTS (LBS.) MODEL SIZE 3 TON 4 TON 5 TON 565 610 645 N04 605 - - N06 - 660 - N08 625 - 705 DH (Cooling Only) BASIC UNIT DH (Gas/Electric) N10 - 680 715 D06 615 660 695 D10 635 680 715 Economizer Motorized Damper OPTIONS 5 - 7 kW Electric Heater 10 - 15 kW 20 - 30 kW Roof Curb ACCY. Barometric Relief / Fixed Air Damper 50 26 18 23 28 92 10 5 Belt-Drive Blower FIGURE 11 - ROOF CURB DIMENSIONS 32 Unitary Products Group 036-21506-004-A-1105 GUIDE SPECIFICATIONS GENERAL Units shall be manufactured by York International Unitary Products Group in an ISO 9001 certified facility. York's Sunline Ultra® units are convertible single package units. Although the units are primarily designed for curb mounting on a roof, they can also be slab-mounted at ground level or set on steel beams above a finished roof. Cooling only, cooling with gas heat and cooling with electric heat models are available with a wide variety of factory-mounted options and field-installed accessories to make them suitable for almost every application. All units are self-contained and assembled on full perimeter base rails with holes in the four corners for overhead rigging. Every unit is completely piped, wired, charged and tested at the factory to simplify the field installation and to provide years of dependable operation. All models (including those with an economizer) are suitable for either bottom or horizontal duct connections. Models with power exhaust are suitable for bottom duct connections only. For bottom duct, remove the sheet metal panels from the supply and return air openings through the base of the unit. For horizontal duct, remove the supply and return air panels on the rear of the unit. All non-Scroll compressors include crankcase heaters and all compressors have internal pressure relief. Every refrigerant circuit includes a liquid line filter-drier, a discharge line high pressure switch and a suction line with a freezestat and low pressure/loss of charge switch.The unit control circuit includes a 75 VA transformer, a 24-volt circuit breaker and a relay board with a compressor lockout circuit, a terminal strip for thermostat wiring, plus an additional set of pin connectors to simplify the interface of additional field controls. All units have long lasting powder paint cabinets with 1000 hour salt spray test approval under ASTMB117 procedures. All models are CSA listed. All models include a 1-year limited warranty on the complete unit. Compressors and electric heater elements carry a 5-year warranty. Aluminized steel and Stainless steel tubular heat exchangers carry a 10-year warranty. DESCRIPTION Units shall be factory-assembled, single packaged, Electric Cooling/Gas Heat, Electric Cooling/Optional Electric Heat and designed for outdoor mounted installation. The 3 ton, 4 ton and 5 ton units shall have minimum SEER ratings of 12.2, 13.2 and 12.2 respectively. They shall have built-in field convertible duct connections for down discharge supply/return or horizontal discharge supply/return, and be available with factory installed options or field installed accessories. The units shall be factory wired, piped, charged with R-22 refrigerant and factory tested prior to shipment. All unit wiring shall be both numbered and color coded. All units the cooling performance shall be rated in accordance with DOE and ARI test procedures. Units shall be CSA listed, classified to ANSI Z21.47, UL 1995/CSA No. 236 standards. Unitary Products Group UNIT CABINET Unit cabinet shall be constructed of G90 galvanized steel, with exterior surfaces coated with a non-chalking, powdered paint finish, certified at 1000 hours salt spray test per ASTMB117 standards. Indoor blower section shall be insulated with a minimum 1/2” thick insulation, coated on the airside. Aluminum foil faced insulation shall be used in the furnace compartment and be fastened with ridged fasteners to prevent insulation from entering the air stream. Cabinet panels shall be “large” size, easily removable for servicing and maintenance. Full perimeter base rails shall be provided to assure reliable transit of equipment, overhead rigging and proper sealing on roof curb applications. Disposable 1" filters shall be furnished and be accessible through a removable access door, sealed airtight. Units filter track shall be designed to accommodate either 1" or 2" filters. Fan performance measuring ports shall be provided on the outside of the cabinet to allow accurate air measurements of evaporator fan performance without removing panels or creating air bypass of the coils. Condensate pan shall be internally sloped and conform to ASHRAE 62-89 self-draining standards. Condensate connection shall be a minimum of 3/4” I.D. female and be a ridged mount connection. INDOOR (EVAPORATOR) FAN ASSEMBLY The indoor fan shall be a factory installed belt drive assembly that includes an adjustable pitch motor pulley. Job site selected (B.H.P.) brake horsepower shall not exceed the motors nameplate horsepower rating, plus the service factor. Units shall be designed not to operate above service factor. Fan wheel shall be double-inlet type with forward-curved blades, dynamically balanced to operate smoothly throughout the entire range of operation. Airflow design shall be constant air volume. Bearings shall be sealed and permanently lubricated for longer life and no maintenance. OUTDOOR (CONDENSER) FAN ASSEMBLY The outdoor fan shall be of the direct-driven propeller type, discharge air vertically, have aluminum blades riveted to a corrosion resistant steel spider bracket and shall be dynamically balanced for smooth operation. The outdoor fan motor shall be totally enclosed with permanently lubricated bearings, internally protected against overload conditions and staged independently. REFRIGERANT COMPONENTS Compressor: a. Shall be internally protected with internal high-pressure relief and over temperature protection. b. Shall have internal spring isolation and sound muffling to minimize vibration and noise, and be externally isolated on a dedicated, independent mounting. 33 036-21506-004-A-1105 Coils: GAS HEATING SECTION (SINGLE OR 2 STAGE) a. Evaporator and condenser coils shall have aluminum plate fins mechanically bonded to seamless internally enhanced copper tubes with all joints brazed. Special Phenolic coating shall be available as a factory option. b. Evaporator and Condenser coils shall be of the direct expansion, draw-thru, design. Refrigerant Circuit and Refrigerant Safety Components shall include: a. Thermal expansion devices (TXV’s). b. Filter drier/strainer to eliminate any moisture or foreign matter. c. Accessible service gage connections on both suction and liquid lines to charge, evacuate, and measure refrigerant pressure during any necessary servicing or troubleshooting, without losing charge. d. Shall be designed with induced draft combustion with post purge logic, energy saving direct spark ignition, and redundant main gas valve. Venter wheel shall be constructed of stainless steel for corrosion resistance. The heat exchanger shall be of the tubular type, constructed of T1-40 aluminized steel for corrosion resistance and allowing minimum mixed air entering temperature of 25°F. Burners shall be of the inshot type, constructed of aluminum coated steel and contain air mixture adjustments. All gas piping shall enter the unit cabinet at a single location through either the side or curb without any field modifications. Integrated control boards shall provide timed control of evaporator fan functioning and burner ignition. Heating section shall be provided with the following minimum protection: The refrigeration system shall provide at least 15°F of sub-cooling at design conditions. a. Primary and auxiliary high-temperature limit switches. b. Induced draft motor speed sensor. c. Flame roll out switch. d. Flame proving controls. ELECTRIC HEATING SECTION UNIT CONTROLS 34 a. Unit shall be complete with self-contained low-voltage control circuit protected by a resetable circuit breaker on the 24-volt transformer side. b. Unit shall incorporate a lockout circuit which provides reset capability at the space thermostat or base unit, should any of the following standard safety devices trip and shut off compressor. c. Loss-of-charge/Low-pressure switch. An electric heating section, with nickel chromium elements, shall be provided in a range of 5 thru 30 KW, offering two stages of capacity - 16 KW and above on 208/230 volt heaters and 20 KW and above on 460 and 575 volt heaters. The heating section shall have a primary limit control(s) and automatic reset to prevent the heating element system from operating at an excessive temperature. The heating section assembly shall slide out of the unit for easy maintenance and service. Units with Electric Heating shall be wired for a single point power supply with branch circuit fusing (where required). d. High-pressure switch. UNIT OPERATING CHARACTERISTICS e. Freeze-protection thermostat, evaporator coil. f. If any of the above safety devices trip, a LED (lightemitting diode) indicator shall flash a diagnostic code that indicates which safety switch has tripped. g. Unit shall incorporate “AUTO RESET” compressor over temperature, over current protection. h. Unit shall operate with conventional thermostat designs and have a low voltage terminal strip for easy hook-up. i. Unit control board shall have on-board diagnostics and fault code display. j. Standard controls shall include anti-short cycle and low voltage protection, and permit cooling operation down to 0°F. a. Unit shall be capable of starting and running at 125°F outdoor temperature, exceeding maximum load criteria of ARI Standard 210/240. The compressor, with standard controls, shall be capable of operation down to 0°F outdoor temperature. Unit shall be provided with fan time delay to prevent cold air delivery before heat exchanger warms up (Gas heat only). ELECTRICAL REQUIREMENTS All unit power wiring shall enter unit cabinet at a single factory provided location and be capable of side or bottom entry, to minimize roof penetrations and avoid unit field modifications. Separate side and bottom openings shall be provided for the control wiring. STANDARD LIMITED WARRANTIES k. Control board shall monitor each refrigerant safety switch independently. • Compressor 5 Years • Heat Exchanger 10 Years l. Control board shall retain last 5 fault codes in non volatile memory which will not be lost in the event of a power loss. • Electric Heat Element 5 Years • Other Parts 1 Year Unitary Products Group 036-21506-004-A-1105 OPTIONAL OUTDOOR AIR (Shall be made available by either/or): • • ELECTRONIC ENTHALPY AUTOMATIC ECONOMIZER- Outdoor and return air dampers that are interlocked and positioned by a fully-modulating, spring return damper actuator. The maximum leakage rate for the outdoor air intake dampers shall not exceed 2% when dampers are fully closed and operating against a pressure differential of 0.5 IWG. A unit-mounted potentiometer shall be provided to adjust the outdoor and return air damper assembly to take in CFM of outdoor air to meet the minimum ventilation requirement of the conditioned space during normal operation. During economizer operation, a mixed-air temperature control shall modulate the outdoor and return air damper assembly to prevent the supply air temperature from dropping below 55°F. Changeover from compressor to economizer operation shall be provided by an integral electronic enthalpy control that feeds input into the basic module. The outdoor intake opening shall be covered with a rain hood that matches the exterior of the unit. Water eliminator/filters shall be provided. Simultaneous economizer/compressor operation is also possible. Dampers shall fully close on power loss. MOTORIZED OUTDOOR AIR DAMPERS - Outdoor air dampers are positioned by a 2-position, spring-return damper actuator. The maximum leakage rate for the outdoor air intake dampers shall not exceed 2% when dampers are fully closed and operating against a pressure differential of 0.5 IWG. A unit-mounted potentiometer shall be provided to adjust the outdoor damper assembly to take in the design CFM of outdoor air to meet the ventilation requirements of the conditioned space during normal operation. Whenever the indoor fan motor is energized, the dampers open up to one of two pre-selected positions - regardless of the outdoor air enthalpy. Dampers return to the fully closed position when the indoor fan motor is de-energized. Dampers shall fully close on power loss. • HIGH ALTITUDE - PROPANE GAS - Contains orifices required for applications between 2000 and 6000 feet altitude. Must be used with propane conversion kit. • LOW NOX - Required to reduce the emission of nitrogen oxides below 40 nanograms per joule. • GAS PIPING - Contains 1/2” pipe nipples, fittings and gas cock (including panel assess gaskets) required for bottom gas supply connection with external shut off. • POWER EXHAUST OPTION - To work in conjunction with economizers. • ELECTRIC HEATERS • ECONOMIZER/MOTORIZED DAMPER RAIN HOOD Contains all hood panels and the hardware for assembling. • MANUAL OUTDOOR AIR DAMPER • COIL GUARD KIT - Guard for cooling coil. • HAIL GUARD • FLUE EXHAUST EXTENSION OTHER FACTORY INSTALLED OPTIONS • POWER EXHAUST OPTION - To work in conjunction with economizers. • STAINLESS STEEL HEAT EXCHANGER • STAINLESS STEEL DRAIN PAN • BOTTOM DRAIN CONNECTION • TECHNICOAT PHENOLIC COATED CONDENSER AND EVAPORATOR COIL • ELECTRONIC SINGLE ENTHALPY ECONOMIZER • DIRTY FILTER SWITCH • PHASE MONITOR • COIL GUARD OTHER PRE-ENGINEERED ACCESSORIES AVAILABLE • POWERED GFI CONVENIENCE OUTLET • • NON-POWERED GFI CONVENIENCE OUTLET • BAS CONTROLS (Simplicity™ INTELLI-Comfort™, CPC, JOHNSON, HONEYWELL, NOVAR) • BAS READY ECONOMIZER (BELIMO ACTUATOR WITHOUT A CONTROLLER) • HINGED FILTER DOOR ACCESS AND TOOLESS ACCESS PANELS • 2" PLEATED FILTERS • DISCONNECT SWITCH • SUPPLY AIR SMOKE DETECTOR • RETURN AIR SMOKE DETECTOR • • • ROOF CURB - 14"and 8” high, full perimeter curb with wood nailer (shipped knocked-down). BAROMETRIC RELIEF DAMPER - Contains a rain hood, air inlet screen, exhaust damper and mounting hardware. Used to relieve internal air pressure through the unit. PROPANE CONVERSION KIT - Contains new orifices and gas valve parts to convert from natural to L.P. gas. One per unit required. HIGH ALTITUDE - NATURAL GAS - Contains orifices required for applications between 2000 and 6000 feet altitude. Unitary Products Group 35 Subject to change without notice. Printed in U.S.A. Copyright © 2005 by Unitary Products Group. All rights reserved. Unitary Products Group 5005 York Drive 036-21506-004-A-1105 Supersedes: 036-21506-003-C-0405 Norman OK 73069 ">
Advertisement
Key Features
- Powder Paint finish
- Permanently lubricated motors
- Bottom or side air discharge
- Simplicity Control Board
- Copper tube/aluminum fin coils
- Easy access to all components
- Rigging holes in base rails
- Fork lift slots on three sides
- Single point power connection
- Complete factory package
Frequently Answers and Questions
What are the sizes of the YORK Sunline Ultra units?
The Sunline Ultra units are available in 3, 4, and 5 ton sizes.
What are the applications for the YORK Sunline Ultra units?
These units are designed for light commercial and commercial applications.
What are the warranties on the YORK Sunline Ultra units?
The Sunline Ultra units come with a one-year parts warranty, a five-year parts warranty on the compressor and electric heat elements, and a ten-year parts warranty on the gas-fired heat exchangers.