Agilent N8480 Series Thermocouple Power Sensors

Agilent N8480 Series Thermocouple Power Sensors
Quick Fact Sheet
Agilent N8480 Series Thermocouple Power Sensors
With best-in-class linearity, industry’s widest frequency and dynamic range, and EEPROM
capability. Agilent N8480 series sensors are widely used in the wireless communications,
electronics manufacturing, aerospace/defense applications, and beyond.
Additional N8488A is now available to meet all your test needs
Key features
• World’s first AC-coupled sensor with widest frequency
range (N8488A)
• High accurate results with best-in-class power linearity
of less than 1%
• The industry’s widest dynamic range in a thermocouple
power measurement solution
• Calibrate easily with automatic upload of calibration
factors using the built-in EEPROM feature
• Easily replace the 8480 Series sensors with SCPI code
compatibility (with option CFT, except for N8488A)
• Get backward compatibility with Agilent EPM Series
(new N1913A/14A, E4418B/19B), EPM-P Series
(E4416A/17A) and P-Series (N1911A/12A) power
meters
Note: N8480 sensors are not compatible with legacy 43x power meters
Key specifications
Frequency range
100 kHz to 67 GHz (usable up to 70 GHz, sensor
dependent)
Dynamic range
55 dB (–35 dBm to +44 dBm, sensor dependent)
Power linearity
< 1%
Agilent’s new N8488A with widest frequency coverage:
10 MHz to 67 GHz (usable up to 70 GHz)
Quick Fact Sheet
Agilent N8480 Series Thermocouple Power Sensors
N8485A
10 MHz to
26.5 GHz
–35 to +20 dBm (STD)
–30 to +20 dBm (CFT)
3.5 mm
(male)
8485A
N8487A
50 MHz to
50 GHz
–35 to +20 dBm (STD)
–30 to +20 dBm (CFT)
2.4 mm
(male)
8487A
N8481B
10 MHz to
18 GHz
–5 to +44 dBm (STD)
0 to +44 dBm (CFT)
N-type
(male)
8481B
N8482B
100 kHz to
6 GHz
–5 to +44 dBm (STD)
0 to +44 dBm (CFT)
N-type
(male)
8482B
N8481H
10 MHz to
18 GHz
–15 to +35 dBm (STD)
–10 to +35 dBm (CFT)
N-type
(male)
8481H
N8482H
100 kHz to
6 GHz
–15 to +35 dBm (STD)
–10 to +35 dBm (CFT)
N-type
(male)
8482H
N8486AR
26.5 GHz to
40 GHz
–35 to +20 dBm (STD)
–30 to +20 dBm (CFT)
Waveguide
R8486A
N8486AQ
33 GHz to
50 GHz
–35 to +20 dBm (STD)
–30 to +20 dBm (CFT)
Waveguide
Q8486A
N8488A
(NEW)
10 MHz to
67 GHz
–35 to + 20 dBm (STD)
1.85 mm
(male)
–
Options description:
Affordable
price without
1. STD - N8480 sensors with EEPROM, automatic loading of cal
compromising
factors to power meter.
performance
2. CFT - N8480 sensors with calibration factor data provided on
the label attached to the sensor. Similar functionality as the 8480 series.
Cables
Calibration
Warranty
Documentation
Option 200
APC-7 (male) connector for N8481A
only
11730A/B/C/D/E/F
cable
For EPM* Series power meters:
1.5m (5 ft)/3.0 m (10 ft)/6.1 m
(20 ft)/15.2 m (50 ft)/30.5 m
(100 ft)/61.0 m (200 ft), grey
E9288A/B/C cable
For EPM* and EPM-P Series power
meters: 1.5 m (5 ft)/3.0 m
(10 ft)/10.0m (31 ft), blue
N1917A/B/C cable
For P-Series power meters: 1.5 m
(5 ft)/3.0 m (10 ft)/10.0 m (31 ft)
Option 1A7
ISO 17025 calibration with test data
Option A6J
ANSI Z540 calibration with test data
Option R-51B-001-3C
Extended warranty and service plan
from 1 year to 3 years
Option R-51B-001-5C
Extended warranty and service plan
from 1 year to 5 years
Option OB1
Operating and service guide (English)
Option ABJ
Operation and service guide
(Japanese)
1. EPM Series includes the N1913A/14A and E4418B/19B.
Recommended service options
Additional two years of Return-to-Agilent warranty
Additional two years of Return-to-Agilent calibrations
For more information go to www.agilent.com/find/removealldoubt
Technical data, availability, and pricing subject to change without notice.
© Agilent Technologies, Inc. 2012, Printed in USA, March 15, 2012
5989-9116EN
E930XA/H Series
–50 to +30 dBm
U200XH Series
–50 to +30 dBm
848XA Series
–30 to +20 dBm
OPT-H25
OPT-H19
V8486A W8486A
8483A (75 Ω)
N848XA Series
–35 to +20 dBm
N8486AQ
N8486AR
N8488A
N8487A
N8485A
OPT33
N8481A
N8482A
OPT-H24
E9300A
E9301A
OPT-H18
E9404A
U2004A
U2002A
U2001A
U2000A
V3500A
E930XA Series
–60 to +20 dBm
U200XA Series
–60 to +20 dBm
V3500A
–63 to + 20 dBm
E441XA Series
–70 to +20 dBm
E4412A
E4413A
OPT-H33
8487D
848XD Series
–70 to –20 dBm
8481D
Legend
Q8486D
R8486D
OPT33
8485D
Frequency
110 GHz
8482A
N8481B
N8482B
E9300B
E9301B
U2001B
U2000B
N8481H
N8482H
E9300H
E9301H
E9300A
E9304A
U2002H
U2001H
U2000H
67 GHz
N-type
(male)
Type-N (male) connector for
N8481A/N8482A/N8481B/N8482B/
N8481H/N8482H
• 3.5 mm (male) connector for
N8485A
• 2.4 mm (male) connector for
N8487A
• Waveguide connector for
N8486AR/N8486AQ
• 1.85 mm (male) connector for
N8488A
75 GHz
–35 to +20 dBm (STD)
–30 to +20 dBm (CFT)
Option 100
Power
N848XB Series
–5 to +44 dBm
N930XB Series
–30 to +44 dBm
U200XB Series
–30 to +44 dBm
N848XH Series
–15 to +35 dBm
50 GHz
100 kHz to
6 GHz
Connectors
Description
40 GHz
N8482A
Type
33 GHz
8481A
24 GHz
N-type
(male)
26.5 GHz
–35 to +20 dBm (STD)
–30 to +20 dBm (CFT)
6 GHz
10 MHz to
18 GHz
18 GHz
N8481A
2 GHz
Replaced
model
4.2 GHz
Connector
type
50 MHz
Power range
10 MHz
Frequency
range
Agilent average power sensors
9 kHz
Model
Accessories, calibration and documentation
options
100 kHz
Ordering Information
(NEW)
N848X average
thermocouple sensor
848X thermocouple
sensor
E930X 2-path diode
true-average sensor
848XD average
diode sensor
E441X 1-path diode
CW- only sensor
U200X USB
sensors
V3500A Handheld RF
power meter
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising