GB1550-SFP
RoHS Compliant
TX-1550/RX-1310 nm Single-mode Bi-directional (15dB margin)
SFP LC Simplex Connector, with Diagnostic Monitoring
1.0625Gbd Fiber Channel/1.25 Gigabit Ethernet
Features
„ Compliant with IEEE802.3z Gigabit Ethernet
Standard
„ Compliant with Fiber Channel 100-SM-LC-L
standard
„ Multi rate 125Mbps to 1.25Gbps
„ Industry standard small form pluggable (SFP)
package
„ Simplex LC connector
„ Differential LVPECL inputs and outputs
„ Single power supply 3.3V
„ TTL signal detect indicator
„ Hot Pluggable
„ Class 1 laser product complies with EN 60825-1
Ordering Information
PART NUMBER
TX/RX
TEMPERATURE
LD Type
Distance
GB1550-SFP-LC.S20
1550/1310
0°C to 70 °C
1550 DFB
20km
Option:-40°C to 85 °C
1550 DFB
20km
GB1550-SFP-LC.S20(WT) 1550/1310
Diagnostics
Parameter
Range
Accuracy
Unit
Temperature
-20 to 95
±3
Voltage
0 to VCC
± 0.1
V
Bias Current
0 to 120
±5
mA
TX Power
-11 to 0
± 3 dB
dBm
RX Power
-23 to –3
± 3 dB
dBm
Page 1 of 10
Version 1.1
Date:11/3/2010
Calibration
o
C
TEL: 03-3836-5611
FAX: 03-3836-5614
Website: http://www.dci.jp
External
RoHS Compliant
TX-1550/RX-1310 nm Single-mode Bi-directional (15dB margin)
SFP LC Simplex Connector, with Diagnostic Monitoring
1.0625Gbd Fiber Channel/1.25 Gigabit Ethernet
Absolute Maximum Ratings
PARAMETER
SYMBOL
MIN
MAX
UNITS
TS
−40
85
°C
Supply Voltage
Vcc
−0.5
4.0
V
Input Voltage
VIN
−0.5
Vcc
V
Output Current
Io
---
50
mA
Operating Current
IOP
---
400
mA
SYMBOL
MIN
MAX
UNITS
NOTE
Case Operating Temperature
TC
0
-40
70
85
°C
GB1550-SFP-LC.S20
GB1550-SFP-LC.S20(WT)
Supply Voltage
Vcc
3.1
3.5
V
Supply Current
ITX + IRX
---
300
mA
Storage Temperature
NOTE
Recommended Operating Conditions
PARAMETER
Page 2 of 10
Version 1.1
Date:11/3/2010
TEL: 03-3836-5611
FAX: 03-3836-5614
Website: http://www.dci.jp
RoHS Compliant
TX-1550/RX-1310 nm Single-mode Bi-directional (15dB margin)
SFP LC Simplex Connector, with Diagnostic Monitoring
1.0625Gbd Fiber Channel/1.25 Gigabit Ethernet
Transmitter Electro-optical Characteristics
Vcc = 3.1 V to 3.5 V, TC = 0 °C to 70 °C (-40 °C to 85 °C)
PARAMETER
SYMBOL
MIN
TYP.
MAX
UNITS
NOTE
−8
---
−2
dBm
Average
ER
9
---
---
dB
Center Wavelength
λC
1530
1550
1570
nm
Spectral Width (-20dB)
Δλ
---
---
1
nm
SMSR
30
---
---
dB
Rise/Fall Time, (20−80%)
Tr, f
---
---
260
ps
Relative Intensity Noise
RIN
---
---
−120
dB/Hz
TJ
---
---
227
ps
Output Optical Power
9/125 μm fiber
Pout
Extinction Ratio
Side Mode Suppression Ratio
Total Jitter
Output Eye
Compliant with IEEE802.3z
Max. Pout TX-DISABLE Asserted
POFF
---
---
−45
dBm
Differential Input Voltage
VDIFF
0.4
---
2.0
V
Transmit Fault Output-Low
TX_FAULTL
0.0
---
0.5
V
Transmit Fault Output-High
TX_FAULTH
2.4
---
VCC
V
Time to initialize, include reset of
TX_FAULT
t_init
---
---
300
ms
TX_FAULT from fault to assertion
t_fault
---
---
100
μs
TX_DISABLE time to start reset
t_reset
10
---
---
μs
Page 3 of 10
Version 1.1
Date:11/3/2010
TEL: 03-3836-5611
FAX: 03-3836-5614
Website: http://www.dci.jp
RoHS Compliant
TX-1550/RX-1310 nm Single-mode Bi-directional (15dB margin)
SFP LC Simplex Connector, with Diagnostic Monitoring
1.0625Gbd Fiber Channel/1.25 Gigabit Ethernet
Receiver Electro-optical Characteristics
Vcc = 3.1 V to 3.5 V, TC = 0 °C to 70 °C (-40 °C to 85 °C)
PARAMETER
SYMBOL
MIN
TYP.
MAX
UNITS
NOTE
Optical Input Power-maximum
PIN
−2
---
---
dBm
BER < 10−12
RX Sensitivity @GbE
PIN
---
---
−23
dBm
PRBS7, BER < 10−12
RX Sensitivity @1x FC
PIN
---
---
−23
dBm
PRBS7, BER < 10−12
RX Sensitivity @OC-12
PIN
---
---
−23
dBm
PRBS23, BER < 10−10
RX Sensitivity @OC-3
PIN
---
---
−23
dBm
PRBS23, BER < 10−10
RX Sensitivity @125Mbps
PIN
---
---
−23
dBm
PRBS7, BER < 10−10
Operating Center Wavelength
λC
1260
---
1360
nm
Optical Return Loss
ORL
14
---
---
dB
λ=1260~1360nm
Optical isolation
ISO
---
---
-45
dB
λ=1480~1580nm
Signal Detect-Asserted
PA
---
---
−23
dBm
Signal Detect-Deasserted
PD
−35
---
---
dBm
VDIFF
0.5
---
1.2
V
T r, f
---
---
0.35
ns
RX_LOSL
0
---
0.5
V
RX_LOSH
2.4
---
VCC
V
Differential Output Voltage
Data Output Rise, Fall Time
(20−80%)
Receiver Loss of Signal Output
Voltage-Low
Receiver Loss of Signal Output
Voltage-High
Page 4 of 10
Version 1.1
Date:11/3/2010
TEL: 03-3836-5611
FAX: 03-3836-5614
Website: http://www.dci.jp
RoHS Compliant
TX-1550/RX-1310 nm Single-mode Bi-directional (15dB margin)
SFP LC Simplex Connector, with Diagnostic Monitoring
1.0625Gbd Fiber Channel/1.25 Gigabit Ethernet
Block Diagram of Transceiver
DATA
DATA/
LD Drive
&
Fault Sense
LD
TX_DISABLE
TX_FAULT
PRE.
AMPLIFIER
IC
(0)
(1)
PD
WDM Filter
MOD_DEF
(2)
OPTICAL
DATA
DATA/
SUB-ASSEMBLIES
POST-Amp
&
LOS Detect
RX_LOS
Transmitter and Receiver Optical Sub-assembly Section
A 1550 nm InGaAsP laser and an InGaAs PIN photodiode integrate with an WDM filter to form a bi-directional single fiber
optical subassembly (OSA). The laser of OSA is driven by a LD driver IC which converts differential input LVPECL logic
signals into an analog laser driving current. And, The photodiode of OSA is connected to a circuit providing post-amplification
quantization, and optical signal detection.
TX_FAULT
When sensing an improper power level in the laser driver, the SFP set this signal high and turns off the Laser. TX_FAULT can be
reset with the TX_DISABLE line. The signal is in TTL level.
TX_DISABLE
The TX_DISABLE signal is high (TTL logic “1”) to turn off the laser output.
Receive Loss (RX_LOS)
The RX_LOS is high (logic “1”) when there is no incoming light from the companion transceiver. This signal is normally used by
the system for the diagnostic purpose. The signal is operated in TTL level.
Page 5 of 10
Version 1.1
Date:11/3/2010
TEL: 03-3836-5611
FAX: 03-3836-5614
Website: http://www.dci.jp
RoHS Compliant
TX-1550/RX-1310 nm Single-mode Bi-directional (15dB margin)
SFP LC Simplex Connector, with Diagnostic Monitoring
1.0625Gbd Fiber Channel/1.25 Gigabit Ethernet
Dimensions
DIMENSIONS ARE IN MILLIMETERS
ALL DIMENSIONS ARE 0.2mm UNLESS OTHERWISE SPECIFIED
Page 6 of 10
Version 1.1
Date:11/3/2010
TEL: 03-3836-5611
FAX: 03-3836-5614
Website: http://www.dci.jp
RoHS Compliant
TX-1550/RX-1310 nm Single-mode Bi-directional (15dB margin)
SFP LC Simplex Connector, with Diagnostic Monitoring
1.0625Gbd Fiber Channel/1.25 Gigabit Ethernet
SFP host board mechanical layout
X
Y
S XY
A
1
LX A S
1
PIN1
LX A S
LEGEND
A SB S
PIN1
1.PADS AND VIAS ARE CHASSIS GROUND
2.THROUGH HOLES, PLATING OPTIONAL
3.HATCHED AREA DENOTES COMPONENT
AND TRACE KEEPOUT(EXCEPT CHASSIS
GROUND)
4.AREA DENOTES COMPONENT KEEPOUT
(TRACES ALLOWED)
DIMENSIONS ARE IN MILLIMETERS
A SB S
A SB S
Unit: mm
Page 7 of 10
Version 1.1
Date:11/3/2010
TEL: 03-3836-5611
FAX: 03-3836-5614
Website: http://www.dci.jp
RoHS Compliant
TX-1550/RX-1310 nm Single-mode Bi-directional (15dB margin)
SFP LC Simplex Connector, with Diagnostic Monitoring
1.0625Gbd Fiber Channel/1.25 Gigabit Ethernet
Assembly drawing
1.7¡ Ó
0.9
3.5¡ Ó
0.3
41.73¡ Ó
0.5
PCB
15.25¡ Ó
0.1
10.4¡ Ó
0.1
11.0 REF.
9.8 MAX
CAGE ASSEMBLY
0.4¡ Ó
0.1 BELOW PCB
15.0 MAX
BEZEL
16.25¡ Ó
0.1
MSA-SPECIFIED BEZEL
PCB
DIMENSIONS ARE IN MILLIMETERS
Unit: mm
Page 8 of 10
Version 1.1
Date:11/3/2010
TEL: 03-3836-5611
FAX: 03-3836-5614
Website: http://www.dci.jp
RoHS Compliant
TX-1550/RX-1310 nm Single-mode Bi-directional (15dB margin)
SFP LC Simplex Connector, with Diagnostic Monitoring
1.0625Gbd Fiber Channel/1.25 Gigabit Ethernet
Pin Assignment
Pin-Out
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
PIN 11
PIN 20
PIN 10
PIN 1
Signal Name
Description
TGND
TX_FAULT
TX_DISABLE
MOD_DEF (2)
MOD_DEF (1)
MOD_DEF (0)
RATE SELECT
RX_LOS
RGND
RGND
RGND
Transmit Ground
Transmit Fault
Transmit Disable
SDA Serial Data Signal
SCL Serial Clock Signal
TTL Low
Open Circuit
Receiver Loss of Signal, TTL High, open collector
Receiver Ground
Receiver Ground
Receiver Ground
Receive Data Bar, Differential PECL, ac coupled
Receive Data, Differential PECL, ac coupled
Receiver Ground
Receiver Power Supply
Transmitter Power Supply
Transmitter Ground
Transmit Data, Differential PCEL, ac coupled
Transmit Data Bar, Differential PCEL, ac coupled
Transmitter Ground
RX−
RX+
RGND
VCCR
VCCT
TGND
TX+
TX−
TGND
Page 9 of 10
Version 1.1
Date:11/3/2010
TEL: 03-3836-5611
FAX: 03-3836-5614
Website: http://www.dci.jp
RoHS Compliant
TX-1550/RX-1310 nm Single-mode Bi-directional (15dB margin)
SFP LC Simplex Connector, with Diagnostic Monitoring
1.0625Gbd Fiber Channel/1.25 Gigabit Ethernet
Eye Safety Mark
The LS4 series singlemode transceiver is a class 1 laser
product. It complies with EN 60825-1 and FDA 21 CFR
1040.10 and 1040.11. In order to meet laser safety
requirements the transceiver shall be operated within the
Absolute Maximum Ratings.
Required Mark
Class 1 Laser Product
Complies with
21 CFR 1040.10 and 1040.11
Caution
All adjustments have been done at the factory before
the shipment of the devices. No maintenance and user
serviceable part is required. Tampering with and
modifying the performance of the device will result in
voided product warranty.
Note : All information contained in this document is subject to change without notice.
Page 10 of 10
Version 1.1
Date:11/3/2010
TEL: 03-3836-5611
FAX: 03-3836-5614
Website: http://www.dci.jp
Was this manual useful for you? yes no