HydroBoost In-Wall Bottle Filler with HRF-ER FILTERED MODEL HTHBWF-HRFER

HydroBoost  In-Wall Bottle Filler with HRF-ER FILTERED MODEL HTHBWF-HRFER
HydroBoost In-Wall Bottle Filler
with HRF-ER
®
FILTERED
MODEL HTHBWF-HRFER
These water coolers are certified to
NSF/ANSI 61 and 372.
GENERAL
In-wall, recessed bottle filling station paired
with the single Contour™ refrigerated fountain
Includes 3000 gallon capacity WaterSentry®
Plus filtration system.
HYDROBOOST ® BOTTLE FILLER
In-wall, recessed design with solid lower panel.
Quick fill rate is 1.1 gallons per minute. Includes
laminar flow to provide a clean fill with minimal
splash and easy maintenance. Equipped with
automatic 20-second shut-off timer. User interface design makes touchless operation intuitive.
Key plastic components are integrated with silver
ion anti-microbial protection to inhibit growth of
mold and mildew.
Designed with hinged top and bottom stainless
steel panels for easy access and service.
GREEN COUNTER™
Visually displays count of plastic bottles saved
from waste. (Based on 16 oz. bottles)
WATERSENTRY ® PLUS FILTRATION
Equipped with the HWF3000 WaterSentry ® Plus
Filter which is designed to reduce lead particles
and chlorine. Also reduces discoloration and
odors from incoming water. Features include the
Quick-Disconnect,1/4 turn installation and auto
inlet shut-off valve that closes when the filter is
removed.
Green, yellow, and red LEDs visually indicate
when filter maintenance is required. For service
replacement, order as:
55898C - Single replacement filter
55898C_3PK - Filter three pack.
55898C_12PK - Filter twelve pack.
55898C_24PK - Filter twenty-four pack.
55898C_48PK - Filter forty-eight pack.
SUGGESTED SPECIFICATION
Model HTHBWF-HRFER provides 8.0 gph
of 50ºF drinking water at 90ºF ambient and 80ºF
inlet water. Bottle filler shall be recessed design
and include electronic sensor activation with 20second automatic water shut-off. Shall provide
1.1 gpm flow rate with laminar flor to prevent
splashing. Shall include anti-microbial protected
plastic components to prevent mold and mildew.
Shall include WaterSentry® Plus filter, certified to
NSF/ANSI 61 and 372 for lead reduction, with
visual monitor to indicate when replacement is
necessary. Shall include visual display of plastic
bottles saved from waste. Fountain shall be oval
design with self-closing pushbars and contoured
basin. Shall include water conservation bubbler
with auto stream height regulator. Shall include
SJ8 water chiller. Shall meet ADA guidelines for
reach ranges, when properly installed. Shall be
lead-free design which meets the Safe Drinking
Water Act and is certified to NSF/ANSI 61 & 372.
Shall be certified to UL399 and CAN/CSA 22.2
No. 120 electrial requirements.
FOUNTAIN
Features contoured basin and softly rounded corners
and edges.
HALSEY TAYLOR DOUBLE BUBBLER ™
Exclusive one-piece, chrome-plated two-stream moundbuilding bubbler with non-removable anti-squirt feature
and integral hood insures a satisfying drink of water.
Each HTHBWF-HRFER is shipped in 6 cartons
including:
HYDROBOOST Station with Solid Lower Panel
HRF-ER Fountain
Mounting Frames (2)
HWF3000 WaterSentry® Plus Filter
Cooling unit - SJ8
NOTE: Continued product improvement makes
specifications subject to change without
notice. See Halsey Taylor website for most
current spec sheet.
JOB NAME:
AUTOMATIC STREAM HEIGHT REGULATOR
Self-closing assembly is located inside unit to prevent
tampering. A constant stream height is automatically
maintained under line pressure that varies from 20 to
105 psi.
PUSHBUTTON ACTIVATION
Self-closing, vandal-resistant pushbutton does not
require grasping or twisting.
MOUNTING FRAMES
Manufactured from corrosion resistant, galvanized
steel. Open construction design for ease of installation.
Mounting frames can be shipped in advance for roughin installation.
ENGINEER/CONTRACTOR NAME:
APPROVAL:
DATE:
halseytaylor.com
HALSEY TAYLOR, 2222 CAMDEN COURT, OAK BROOK, ILLINOIS 60523
THIRD-PARTY CERTIFIED TO:
* UL399 & CAN/CSA 22.2 NO. 120
* NSF/ANSI 61 and 372
MODEL HTHBWF-HRFER
HydroBoost ® In-Wall Bottle Filler
OPERATING PRESSURES:
Supply water - 105 psi maximum
* Rated for Indoor Use Only
ELECTRICAL
Hydroboost station equipped with electric
cord and three-prong molded rubber plug for
use with 15-amp minimum receptacle.
For the cooling unit, a junction box for a (3)
wire , 10 amp branch circuit is provided.
Rated at 115 volt, 60 Hz, single phase.
Minimum 40 psi supply line pressure required
in special circumstances when both sides of
bilevel are in use simultaneously to ensure
adequate stream height. Does not apply to
non-refrigerated units.
MFWS100
DOUBLE STUD OR 3 INCHES (76 mm)
BETWEEN MOUNTING FRAMES
IF PLACED NEXT TO ANOTHER
FOUNTAIN OR WALL
WOOD OR STEEL
FRAME SHOWN
(NOT PROVIDED)
FRAME
40"
1016mm
1"
25mm
SIDE VIEW
ELECTRICAL INLET
LOCATION ON CHILLER
5/16" SCREWS OR BOLTS
(10 REQ'D-NOT PROVIDED)
8"
1 1/8"
203mm
( 29mm
TO FLOOR LINE
HOOK RODS (2)
P/N 101567443730
4 1/2
114mm
STANDARD HEIGHT
18 3/4"
476mm
INSTALL (2) SCREWS
(P/N 111008343890) IN FRAME
BEFORE INSTALLING IN OPENING
)
3/8" O.D. TUBE CONNECT
(CHILLER WATER INLET)
SHUT OFF VALVE BY OTHERS
SCREWS OR BOLTS
(NOT PROVIDED)
ANDARD HEIGHT
3"
( 79mm )
CHILLER SHELF
P/N 27638C
DOUBLE STUD OR 3" (76mm)
BETWEEN MOUNTING FRAMES
BACK
OF WALL TO
5 1/8"
IF PLACED
NEXT TO
ANOTHER
BE 12" (305mm)
130mm OR WALL
FOUNTAIN
MIN DEPTH
1 1/8"
( 29mm
)
1/4" O.D.
TUBE CONNECT
(CHILLER WATER OUTLET)
3/8" O.D. TUBE CONNECT
(CHILLER WATER INLET)
SHUT OFF VALVE BY OTHERS
1 3/16"
( 30mm )
1/4" O.D. TUBE CONNECT
(CHILLER WATER OUTLET)
9 3/8"
8 1/8"
( 206mm ) ( 238mm )
DOUBLE STUD OR 3" (76mm)
18 3/4"
BETWEEN MOUNTING FRAMES
( 476mm )
IF PLACED NEXT TO ANOTHER
FOUNTAIN OR WALL
FILTER LOCATION
(OPTIONAL)
1 3/16"1 3/16"
( 30mm( 30mm
)
)
19 3/4"
( 502mm )
17 3/8"
( 441mm )
FRONT VIEW / WALL
12" *LAYOUT
1 3/16"
( 30mm )
( 305mm )
MINIMUM
DEPTH
12" *
* 7" minimum depth ( 305mm )
for non-refrigerated models
MINIMUM
38 7/8"
( 987mm )
20 7/16"
( 519mm )
27"
( 681mm )
ELECTRICAL
20 7/16"
( 519mm )
25 1/4" INLET
( 641mm )
* 7" minimum depth
for non-refrigerated models
BACK WALL LINE
1-1/4" (32MM)
WASTE TUBE
FURNISHED
27"
( 681mm )
ELECTRICAL
25 1/4" INLET 25 7/8"
( 641mm3 )1/2" ( 657mm )
( 89mm )
FINISHED FLOOR FINISHED FLOOR
1 1/8"
( 29mm )
FILTER LOCATION
(OPTIONAL)
DEPTH
2 7/8"
( 73mm )
1-1/4" (32MM)
WASTE TUBE
FURNISHED
2 7/8"20 3/8"
( 73mm
)
( 518mm
)
20 3/8"
( 518mm )
FINISHED FLOOR
9 3/8"
( 238mm )
18 3/4"
( 476mm )
4"
( 102mm )
BACK WALL LINE
38 7/8"
( 987mm )
8 1/8"
( 206mm )
FLOOR LINE
4"
( 102mm )
19 3/4"
( 502mm )
17 3/8"
( 441mm )
3"
( 79mm )
25 7/8"
3 1/2" ( 657mm )
( 89mm )
FINISHED FLOOR
11"
( 279mm )
1 1/8"
4 1/2"( 29mm )
( 116mm)
11"
( 279mm )
4 1/2"
( 116mm)
Specifications and measurements are subject to change without notification.
Please visit halseytaylor.com for most current version.
Printed in the U.S.A.
MODEL HTHBWF-HRFER
HRF-ER
(CONTINUED)
TOP & SIDE VIEWS
WALL OPENING
IMPORTANT: It is necessary to create a wall
opening 18 3/4 " W x 37 3/4 " H and 4 1/ 2" above
the floor line.
MOUNTING INSTRUCTIONS
Refer to rough-in for location of plumbing and
electrical sources. The support frame is to be
installed first. The shelf for the water chiller
should be assembled to the wall frame, and
then place chiller into position. Hang upper
fountain panel to hanger on frame. Fountain is
to be attached to panel and wall frame. Water
service line, waste line and electrical is
assembled as required. The bottom panel
is attached last, after a final check for leaks
and correct functions of fountains and chiller.
(For details see the installation instructions.)
B
OPERATING PRESSURES:
Supply water - 105 psi maximum
ELECTRICAL DATA
Junction box for a (3) wire 10 AMP branch
circuit. Standard 120 volt, 60 HZ, single phase.
FRONT VIEW
C
D
A = 3/8” O.D. TUBE CONNECT (CHILLER WATER INLET) SHUT OFF VALVE BY OTHERS
B = 1/4” O.D. TUBE CONNECT (WATER OUTLET)
C = 1-1/4” TRAP
D = ELECTRICAL INLET
Printed in the U.S.A.
MODEL HTHBWF-HRFER
HRF-ER MOUNTING FRAME
(CONTINUED)
1.
Cut a rectangular wall opening 18-3/4” (475 mm) W
x 37-3/4” (959 mm) H and 4-1/2” (114 mm) above the
floor line (see Figure 9). The dimensions are required
to obtain proper rim and bubbler heights for
compliance with ANSI standard A117.1.
2.
Reinforce the wall opening on all sides to adequately
support the water fountain. This reinforcement must
support up to 150 lbs. static load and provide a
means for securing the frame assembly in place.
NOTE:
3.
Building construction must allow for
adequate air flow on both sides, top and
back of chiller. A minimum of 4” (102 mm) on
both sides and top is required. See chiller
installation for additional instructions.
Install plumbing and electrical rough-ins. A junction
box for a (3) wire, 10 amp branch circuit is provided on
the inside of the chiller. (Standard 120 Volts, 60 Hz,
and single phase.)
4.
Remove frame and related hardware from
packaging. Release the two shelf rods by cutting
cable ties.
5.
Install the frame squarely in wall opening with frame
upright edges flush with the finished wall surface.
Place shelf inside frame and line up the (2) holes on
each. Insert loose ends of rods into holes on sides of
shelf panel. Using appropriately sized screws or bolts
(not provided), fasten the shelf and frame to the
bottom of wall opening. Secure the frame sides and
top to the wall using (10) 5/16” bolts or screws (not
provided).
NOTE: Be sure that frame is squared in location. Do
not use less than the required screw quantity
and size.
Printed in the U.S.A.