sg244778
SG24-4778-00
RS/6000 SP: Problem Determination Guide
December 1996
This soft copy for use by IBM employees only.
IBML
International Technical Support Organization
RS/6000 SP: Problem Determination Guide
December 1996
This soft copy for use by IBM employees only.
SG24-4778-00
This soft copy for use by IBM employees only.
Take Note!
Before using this information and the product it supports, be sure to read the general information in
Appendix D, “Special Notices” on page 281.
First Edition (December 1996)
This edition applies to Version 2, Release 1 of POWERparallel System Support Programs for use with the AIX 4.1.4
Comments may be addressed to:
IBM Corporation, International Technical Support Organization
Dept. HYJ Mail Station P099
522 South Road
Poughkeepsie, New York 12601-5400
When you send information to IBM, you grant IBM a non-exclusive right to use or distribute the information in any
way it believes appropriate without incurring any obligation to you.
 Copyright International Business Machines Corporation 1996. All rights reserved.
Note to U.S. Government Users — Documentation related to restricted rights — Use, duplication or disclosure is
subject to restrictions set forth in GSA ADP Schedule Contract with IBM Corp.
This soft copy for use by IBM employees only.
Contents
Figures
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tables
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Preface
. . . . . . . . . . . . . . . .
.
How This Redbook Is Organized
The Team That Wrote This Redbook
. . . . . . . .
Comments Welcome
xiii
xv
xv
xvii
xviii
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . .
Chapter 1. Overview
. . . . . . . . . . .
1.1 RS/6000 SP: Hardware and Software
1.1.1 The Control Workstation . . . .
. . . . . . . . . . . .
1.1.2 The Frame
1.1.3 The High Performance Switch .
. . . . . . .
1.2 Problem Determination
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
Chapter 2. The Installation Process
. . . . . . . . . . . . . . . . . . . . . . . .
2.1 Major Steps in Installing and Configuring RS/6000 SP Software . . . . .
2.2 Prepare the Control Workstation . . . . . . . . . . . . . . . . . . . . . . . .
2.2.1 PSSP Paths . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.2.2 AIX Software Components . . . . . . . . . . . . . . . . . . . . . . . . .
2.2.3 Disk Space Requirements . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
2.2.4 RS-232 Control Lines Diagnostics
. . . . . . . . . . . . . . . .
2.2.5 Changing IP Addresses and Hostnames
. . . . . . . . . . . . . . . . . . . . .
2.2.6 Maximum Number of Processes
. . . . . . . . . . . . . . . . . . . . . . . .
2.2.7 Number of Licensed Users
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.2.8 Tunable Values
. . . . . . . . . . . . . . . . . . . . . . . .
2.2.9 /spdata Directory Structure
2.2.10 Install PSSP on the Control Workstation . . . . . . . . . . . . . . . .
2.2.11 PSSP 1.2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.2.12 PSSP 2.1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.2.13 Changes from PSSP 1.2 to PSSP 2.1 . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
2.2.14 PSSP Software Strategy
2.2.15 Obtaining PSSP PTFs Using FixDist . . . . . . . . . . . . . . . . . . .
2.2.16 Determining Software Service Level . . . . . . . . . . . . . . . . . .
2.2.17 Working with PSSP PTFs . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
2.3 Authentication Services Diagnostics
2.4 install_cw Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.4.1 Problems Solving . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.5 Problems with spmon
2.5.1 Problems with System Monitor Commands . . . . . . . . . . . . . . .
2.5.2 Problems Accessing Pulldown Menus of spmon . . . . . . . . . . . .
2.5.3 System Monitor Displays Blanks Instead of the Expected Information
. . . . . . . . . . . . . . . . . . .
2.5.4 Problems with System Monitor GUI
2.5.5 Logging Problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.5.6 Example — Some Nodes Are Missing . . . . . . . . . . . . . . . . . .
2.5.7 Example — spmon Will Not Start . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . .
2.6 Problems with Some PSSP Scripts
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.6.1 setup_authent Script
2.6.2 install_cw Script . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.7 Restore Control Workstation mksysb . . . . . . . . . . . . . . . . . . . . .
 Copyright IBM Corp. 1996
ix
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
1
1
1
2
3
4
7
7
8
8
10
11
11
12
14
14
15
15
16
18
18
19
20
21
22
25
28
29
30
31
32
33
33
36
37
37
38
40
40
42
43
iii
This soft copy for use by IBM employees only.
2.8 NIM Problems . . . . . . . . . . . . . . . . .
2.9 NIM Commands . . . . . . . . . . . . . . . .
2.9.1 NIM Diagnostics . . . . . . . . . . . . .
. . . . . . . . . . .
2.9.2 Setup_server Fails
2.9.3 Debugging NIM Installations . . . . . .
2.10 Network Booting . . . . . . . . . . . . . . .
2.10.1 Scripts Involved in Network Boot . .
. . . .
2.10.2 Node Installation Diagnostics
. . . . . .
2.11 Node Customization Problems
2.11.1 Why a Node Is Not Being Customized
Chapter 3. Kerberos
. . . . . . . .
3.1 Overview . . . . . . . . . . . . .
3.1.1 Authentication . . . . . . .
3.1.2 Authorization . . . . . . . .
3.1.3 Distributed Commands . .
3.1.4 Remote Commands . . . .
3.1.5 .rhosts . . . . . . . . . . . .
3.2 Terminology . . . . . . . . . . .
. . . . . . . . . .
3.2.1 Principal
3.2.2 Instance . . . . . . . . . . .
3.2.3 Realm . . . . . . . . . . . .
. . . . . . . . . . . .
3.2.4 Ticket
. . . . . . . . . . . . .
3.2.5 Key
. .
3.2.6 Ticket-Granting Ticket
3.3 Components . . . . . . . . . . .
3.3.1 ssp.authent 2.1.0.2 . . . . .
3.3.2 ssp.clients 2.1.0.5 . . . . .
. . . . . . . . .
3.4 Install Process
. . . . . . .
3.4.1 setup_authent
3.4.2 install_cw . . . . . . . . . .
3.4.3 setup_server . . . . . . . .
3.4.4 Network Boot . . . . . . . .
3.5 Daemons and Databases . . .
3.5.1 Kerberos Daemon . . . . .
3.5.2 kadmind Daemon . . . . .
3.5.3 kpropd Daemon . . . . . .
. . . . .
3.5.4 /etc/services File
. . . . . . . . .
3.5.5 Databases
3.6 Files . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . .
3.6.1 /.k
3.6.2 $HOME/.klogin . . . . . . .
. . . . . .
3.6.3 / t m p / t k t < u i d >
3.6.4 /etc/krb-srvtab . . . . . . .
. . . . . . . .
3.6.5 /etc/krb.conf
. . . . . .
3.6.6 /etc/krb.realms
3.6.7 /var/adm/SPlogs/kerberos
3.7 Commands . . . . . . . . . . . .
. . . . . . . . . . . . .
3.7.1 kinit
. . . . . . . . . . . . .
3.7.2 klist
3.7.3 kdestroy . . . . . . . . . . .
3.7.4 kstash . . . . . . . . . . . .
3.7.5 dsh and p* Commands . .
3.7.6 rsh and rcp . . . . . . . . .
. . . . . . . . . . . .
3.7.7 sysctl
iv
SP PD Guide
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
44
48
54
56
60
61
62
66
69
69
71
71
71
71
71
71
71
72
72
72
73
73
73
73
74
74
74
74
74
75
75
75
75
75
75
76
76
76
77
77
77
77
78
78
79
79
80
80
80
81
81
82
82
82
This soft copy for use by IBM employees only.
3.8 Solving Problems . . . . . . . . . . .
3.8.1 Daemons . . . . . . . . . . . . .
3.8.2 Tickets . . . . . . . . . . . . . . .
3.8.3 PATH Variable . . . . . . . . . .
. . . . . . .
3.8.4 Configuration Files
3.8.5 TCP/IP . . . . . . . . . . . . . . .
3.8.6 Remote Principals . . . . . . . .
. . . . . . . .
3.8.7 Service Key Files
. . . . . . . . . . . .
3.8.8 PTF Levels
3.8.9 Rebuild the Kerberos Database
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . .
Chapter 4. The Switch
. . . . . . . . . . . . . . . . . . . . . . .
4.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
4.1.1 Software Overview
4.1.2 High Performance Switch and SP Switch Coexistence
. . . . . . . . . . . .
4.1.3 Comparing HiPS and SP Switch
. . . . . . . .
4.1.4 Improvements of SP Switch over HiPS
4.2 Reviewing Switch Boards . . . . . . . . . . . . . . . . . . .
4.3 Switch Topology and Clock Subsystem . . . . . . . . . . .
. . . . . . . . . . . . . . . . . .
4.3.1 Switch Topology Files
4.3.2 Topology File Nomenclature . . . . . . . . . . . . . . .
4.3.3 HiPS Clock Subsystem . . . . . . . . . . . . . . . . . .
4.3.4 SP Switch Clock Subsystem . . . . . . . . . . . . . . .
4.3.5 Switch Clock Files . . . . . . . . . . . . . . . . . . . . .
4.4 Node Behaviors . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . .
4.4.1 Primary Node Behavior
. . . . . . . . . . . .
4.4.2 Primary Backup Node Behavior
4.4.3 Secondary Node Behavior . . . . . . . . . . . . . . . .
. . . . . . . . . . . .
4.4.4 Recovery from a Switch Failure
4.5 Switch Commands . . . . . . . . . . . . . . . . . . . . . . .
4.5.1 The rc.switch Script . . . . . . . . . . . . . . . . . . . .
4.5.2 Switch Initialization . . . . . . . . . . . . . . . . . . . .
4.6 Reviewing Switch Processes . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
4.6.1 Switch Responds
. . . . . . . . . . . . . . . . . . . . . . . .
4.7 Switch Log Files
4.7.1 The out.top Log File . . . . . . . . . . . . . . . . . . . .
4.7.2 Patterns in out.top File . . . . . . . . . . . . . . . . . .
4.7.3 The flt Log File . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
4.7.4 Reading the flt File
4.7.5 Fault Syndrome on the flt File . . . . . . . . . . . . . .
4.8 Additional Problem Determination . . . . . . . . . . . . . .
4.8.1 Debugging Scripts . . . . . . . . . . . . . . . . . . . . .
4.8.2 AIX Error Logging . . . . . . . . . . . . . . . . . . . . .
Chapter 5. System Partitioning . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
5.1 Scope, Rules, and Limitations
5.1.1 Scope of System Partitioning . . . . . . . . . . . . .
5.1.2 Some Rules for Partitioning . . . . . . . . . . . . . .
. . . . . .
5.1.3 Some Limitations of System Partitioning
. . . . .
5.2 Partitioning and the High Performance Switch
. . . .
5.2.1 Partitioning a Single Switch/Frame System
5.2.2 Partitioning a Two Switch/Frame System . . . . . .
5.2.3 Partitioning a Three or More Switch/Frame System
5.2.4 Switch Topologies . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
5.2.5 Configuration Files
82
82
83
83
83
84
84
84
85
85
87
87
. 90
. 91
. 91
. 92
. 93
. 95
. 95
. 99
100
101
102
103
103
103
104
104
104
108
108
110
111
113
116
117
119
120
123
124
124
124
. . . . . . . . . .
. . . . . . . . . .
. . . . . . . . .
. . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . . .
. . . . . . . . . .
. . . . . . . . . .
. . . . . . . . . .
. . . . . . . . . .
. . . . . . . . . .
. . . . . . . . . .
. . . . . . . . . .
. . . . . . . . .
. . . . . . . . . .
. . . . . . . . . .
Contents
125
125
125
126
127
127
128
130
130
131
134
v
This soft copy for use by IBM employees only.
5.3 Creating Partitions . . . . . . . . . . . . . . . . . . . .
5.3.1 Prerequisites to System Partitioning . . . . . . .
5.3.2 Process Overview . . . . . . . . . . . . . . . . . .
5.3.3 Archiving the SDR . . . . . . . . . . . . . . . . . .
5.3.4 Customizing the Partitions . . . . . . . . . . . . .
. . . . . . . . . . . . . .
5.3.5 Verify the Configuration
5.3.6 Applying the System Partitioning . . . . . . . . .
5.3.7 Validating the Partitions and Restoring the SDR
5.4 SDR Reorganization . . . . . . . . . . . . . . . . . . .
5.4.1 SDR Daemons . . . . . . . . . . . . . . . . . . . .
5.4.2 SDR Directory Structure . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
5.4.3 New Object Classes
5.4.4 SDR Locking . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
5.4.5 The Restructured SDR
5.5 Heartbeat Reorganization . . . . . . . . . . . . . . . .
. . .
5.5.1 The Heartbeat before System Partitioning
. . . .
5.5.2 The Heartbeat after System Partitioning
5.5.3 Daemons and Scripts . . . . . . . . . . . . . . . .
5.6 Resource Manager Reorganization . . . . . . . . . .
Chapter 6. Error Logging
. . . . . . . . . . . . . . . . . .
6.1 Error Logging Overview . . . . . . . . . . . . . . . . .
6.1.1 Terms Used by the Error Logging Facility . . . .
6.1.2 Error Logging Commands . . . . . . . . . . . . .
6.1.3 Error Log Files . . . . . . . . . . . . . . . . . . . .
6.2 SP Error Logging . . . . . . . . . . . . . . . . . . . . .
6.2.1 Install and Configure Error Log . . . . . . . . . .
6.2.2 AIX Error Log Facility . . . . . . . . . . . . . . . .
6.2.3 BSD syslog Facility . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
6.2.4 Trimming syslog Files
6.2.5 Maintain Error Logs . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . .
6.2.6 Collecting System Data
6.2.7 SP Error Log . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
6.3 Error Notification Facility
. . . . . . . . . . . . .
6.3.1 Error Notification Objects
. . . . . . . . . .
6.3.2 Error Notification Object Class
. . . . . . .
6.3.3 Adding an Error Notification Object
6.3.4 Mailing Error Reports to the Control Workstation
. . . . . . . . . . . .
6.3.5 Notification on Boot Device
. . . . . . .
6.3.6 Notification Power Loss and PANIC
. . . . . . . . . . . . . . . . . . . . . .
6.4 Error Daemons
6.4.1 AIX Error Daemons . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . .
6.4.2 SP Log Daemons
Chapter 7. Isolating Problems on the SP System
7.1 Isolating Booting Problems . . . . . . . . . .
7.1.1 Booting Process Overview . . . . . . . .
7.1.2 Booting Problems . . . . . . . . . . . . .
7.2 Isolating System Monitor Problems . . . . .
7.3 Isolating Switch Problems . . . . . . . . . . .
7.4 Isolating System Partitioning Problems . . .
Chapter 8. Producing a System Dump
8.1 Handling Systems Dumps . . . . .
8.1.1 How to Start a Dump . . . . .
vi
SP PD Guide
. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
137
137
139
140
141
142
144
144
145
145
147
149
150
150
152
152
154
156
157
159
159
160
161
161
162
163
164
165
168
170
173
174
175
178
180
181
183
185
186
187
187
191
195
195
195
196
197
199
200
201
201
204
This soft copy for use by IBM employees only.
8.1.2 Copying a System Dump . . . . . . . . .
8.1.3 Sending the Dump to the Support Center
. . . .
8.1.4 Using crash to Analyze a Dump
Chapter 9. User and Services Management
9.1 Overview . . . . . . . . . . . . . . . . . .
9.1.1 User Accounts . . . . . . . . . . . .
. . . . . . . . . . .
9.1.2 File Collections
9.1.3 Auto Mount Daemon (Amd) . . . .
. . . . . . . . . . . .
9.1.4 Print Services
9.1.5 Network Time Protocol (NTP) . . .
9.2 Components . . . . . . . . . . . . . . . .
. . . . . . . . . .
9.2.1 ssp.basic 2.1.0.10
. . . . . . . . .
9.2.2 ssp.sysman 2.1.0.7
9.3 Managing User Accounts . . . . . . . .
. . . . . . . . .
9.3.1 Adding an SP User
. . . . .
9.3.2 Changing User Attributes
9.3.3 Login Control . . . . . . . . . . . . .
9.4 Managing File Collections . . . . . . . .
. . . . . . .
9.4.1 Using File Collections
. . . . . . .
9.4.2 supper Hints and Tips
. . . . . . . . . . . . . .
9.5 Managing A m d
9.5.1 Using A m d . . . . . . . . . . . . . .
9.5.2 Amd Hints and Tips . . . . . . . . .
. . . . . . . .
9.6 Managing Print Services
. . . . . . . .
9.6.1 Using Print Services
. . . . . . . . . . . . . .
9.7 Managing NTP
. . . . . . . . . . . . . .
9.7.1 Using NTP
9.7.2 NTP Hints and Tips . . . . . . . . .
Appendix A. RS/6000 SP Script Files
A.1 The setup_authent Script . . . .
. . . . . .
A.2 The install_cw Script
A.3 The setup_server Script . . . . .
. . . . . . .
A.4 The rc.switch Script
Appendix B. The SDR Structure
. . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
213
213
213
213
213
213
213
214
214
214
214
216
217
218
218
219
219
221
221
222
225
225
225
226
226
. . . . . . . . . . . . . . . . . . . . . . . .
229
229
236
239
262
. . . . . . . . . . . . . . . . . . . . . . . . . .
271
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . .
Appendix C. IP Address and Hostname Changes for the SP
. .
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
C.1 SDR Objects
C.2 RS/6000 SP System Files . . . . . . . . . . . . . . . . . . . . .
C.3 Procedures Used When Changing IP Addresses/Hostnames
C.4 Updating the RS/6000 SP Node Interfaces . . . . . . . . . . .
. . . .
C.5 Control Workstation IP Address/Hostname Changes
C.6 Execution on RS/6000 SP Nodes . . . . . . . . . . . . . . . . .
Appendix D. Special Notices
206
208
210
. . . . . . .
273
273
273
275
275
276
279
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
281
Appendix E. Related Publications
. . . . . . . . . . . . . . . .
E.1 International Technical Support Organization Publications
E.2 Redbooks on CD-ROMs . . . . . . . . . . . . . . . . . . . .
E.3 Other Publications . . . . . . . . . . . . . . . . . . . . . . .
How To Get ITSO Redbooks . . . . . . . . . .
How IBM Employees Can Get ITSO Redbooks
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . . . .
. . . . . . . .
. . . . . . . . .
. . . . . . . . .
283
283
283
283
. . . . . . . . . . . . . . . . . .
285
285
Contents
vii
. . . . . . . . . . . . . . . . . . .
This soft copy for use by IBM employees only.
How Customers Can Get ITSO Redbooks
. . . . . . . .
IBM Redbook Order Form
. . . . . . . . . . . . . . . . . . . . . .
286
287
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
289
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
291
List of Abbreviations
Index
viii
SP PD Guide
. . . . . . . . . . . . . . . . . . . . .
This soft copy for use by IBM employees only.
Figures
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
27.
28.
29.
30.
31.
32.
33.
34.
35.
36.
37.
38.
39.
40.
41.
42.
43.
44.
45.
46.
47.
48.
49.
50.
51.
 Copyright IBM Corp. 1996
Control Workstation Connected to the SP Frame
. . . . . . . . . .
Supervisor Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
The High Performance Switch
SP Error Log Structure . . . . . . . . . . . . . . . . . . . . . . . . . .
Sample of a Portion of .profile File . . . . . . . . . . . . . . . . . . .
M i n i m u m Required BOS and Runtime Environment Components
M i n i m u m Required Components of Network Install Manager (NIM)
.
M i n i m u m Required Components of Base Networking Software
Output of lsvg rootvg Command to Check Disk Space . . . . . . .
/etc/hosts File on the Control Workstation . . . . . . . . . . . . . .
Output of a Successful Ping . . . . . . . . . . . . . . . . . . . . . . .
/spdata Directory Structure . . . . . . . . . . . . . . . . . . . . . . .
Obtaining PSSP PTFs Using FixDist . . . . . . . . . . . . . . . . . .
Output of Running install_cw Script . . . . . . . . . . . . . . . . . .
Portion of /etc/inittab That Gets Added from Running install_cw .
Portion of /etc/services That Gets Added from Running install_cw
. . . . . . . . . . . . . . . . . . . . . .
Snapshot of System Monitor
. . . . . . . . . . . . . . . .
The hardmon Daemon Is Not Running
The sdr Daemon Is Not Running . . . . . . . . . . . . . . . . . . . .
The hmacls File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . .
/etc/inittab File after Running install_cw Script
/etc/services File after Running install_cw Script . . . . . . . . . .
Output from setup_server . . . . . . . . . . . . . . . . . . . . . . . .
Extract from the /etc/services File . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
Example Using netstat Command
. . . . .
Example of /etc/krb-srvtab from the Control Workstation
. . . . . . . . . . . . . . .
Example of /etc/krb-srvtab from a Node
Example of a /etc/krb.conf File . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
Example of a /etc/krb.realms File
. . . . . . . . . . . . . . . . . . . . . .
Example of kerberos.log File
. . . . . . . . . . . . . . . . .
Example of admin_server.syslog File
. . . . . . . . . . . . . . . . . . . . . . . . .
Example of klist Output
Example of klist -srvtab Output . . . . . . . . . . . . . . . . . . . . .
inittab Entries for Kerberos Daemons . . . . . . . . . . . . . . . . .
Example of PATH Statement from .profile File . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . .
Sample /etc/krb.conf File
Sample /etc/krb.realms File . . . . . . . . . . . . . . . . . . . . . . .
Example of Host Name Resolution . . . . . . . . . . . . . . . . . . .
Example of klist -srvtab Command on the Control Workstation . .
How to Rebuild the Kerberos Database . . . . . . . . . . . . . . . .
. . . . . . . . . . . .
The HiPS Showing the External Connections
Example of the Cabling for a 128-Way System . . . . . . . . . . . .
. . . . . . . . . . . .
Example of the Cabling on a 48-Way System
The HiPS Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
The SP Switch Board . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
Topology File Sample
Topology File - Example . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . .
Topology File Nomenclature
The HiPS Clock Subsystem . . . . . . . . . . . . . . . . . . . . . . .
The HiPS Chip Clock Tree . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . .
The High Performance Switch Board
2
3
.
4
.
5
.
9
. 10
. 10
. 11
. 11
. 13
. 14
. 15
. 21
. 30
. 30
. 30
. 32
. 39
. 39
. 40
. 43
. 43
. 68
. 76
. 76
. 78
. 78
. 78
. 79
. 80
. 80
. 81
. 81
. 82
. 83
. 83
. 83
. 84
. 84
. 85
. 88
. 89
. 90
. 93
. 95
. 97
. 98
. 99
100
101
102
. . . .
. . . .
. . .
. . .
. . .
. . .
. .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
ix
This soft copy for use by IBM employees only.
52.
53.
54.
55.
56.
57.
58.
59.
60.
61.
62.
63.
64.
65.
66.
67.
68.
69.
70.
71.
72.
73.
74.
75.
76.
77.
78.
79.
80.
81.
82.
83.
84.
85.
86.
87.
88.
89.
90.
91.
92.
93.
94.
95.
96.
97.
98.
99.
100.
101.
102.
103.
104.
105.
106.
x
SP PD Guide
Diagram of the Different Phases on the High Performance Switch
. . . . . . . . . . . . . . . . .
The High Performance Switch Board
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Switch Responds
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
The flt File
Fault Syndrome on flt File . . . . . . . . . . . . . . . . . . . . . . . .
. . . .
Message in Error Report while Estart Has Been Executed
Topology File Insert from a Single Switch 16 Wide Node System
Example of an 8_8 Configuration . . . . . . . . . . . . . . . . . . . .
Insert of Topology File for the First 8-Way Partition . . . . . . . . .
Insert of Topology File for the Second Partition . . . . . . . . . . .
Directory Structure for the Topology Files in PSSP 2.1 . . . . . . .
SMIT Menu for the Fastpath ″syspar″ . . . . . . . . . . . . . . . . .
. . . . . . . . . . .
Flow Chart of the System Partitioning Process
. . . . . . . . .
Example of SMIT Screen for Customizing Layouts
Example of SMIT Screen for Verifying the Configuration . . . . . .
Data Organization of the SDR in PSSP 2.1 . . . . . . . . . . . . . .
PSSP 2.1 SDR Directory Structure . . . . . . . . . . . . . . . . . . .
.
Example of the Heartbeat Subsystem after System Partitioning
. . . . . . . . . . . . . . . . . . . . . . .
Error Logging Components
/etc/syslog.conf file . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
/etc/syslog.pid file
. . . . . . . . . . . . . . . . . . . . . . . . . .
/spdata/sys1/amd.tab
/spdata/sys1/err_methods/EN_pend . . . . . . . . . . . . . . . . . .
/spdata/sys1/err_methods/EN_pend.envs . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
Booting Process Overview
Booting Problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
System Monitor Problems . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Switch Problems
. . . . . . . . . . . . . . . . . . . . .
System Partitioning Problems
. . . . . . . . . . . . . . . . . . . . . . . .
Copying a System Dump
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Using crash
. . . .
Default Values for the Site Environment Information Panel
Output from splstdata -e . . . . . . . . . . . . . . . . . . . . . . . . .
Example of chsh Command on a Node . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . .
Extract from /etc/security/user File
Example of Login by Blocked User ID . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . .
Output from lssrc -s supfilesrv Command
supper Error Messages When PSSP Code Is Mismatched . . . . .
. .
Extract from /var/adm/SPlogs/filec/sup5.13.96.12.02r Log File
. . . . . . . . . . . . . .
supper Errors When Bypassing PTF Set 8
Default Options Starting the Amd Daemon . . . . . . . . . . . . . .
Example of Output from df Command Showing Multiple Mounts .
Sample Amd Map File . . . . . . . . . . . . . . . . . . . . . . . . . .
Error Messages When the Filesystem Is Not Exported . . . . . . .
Output after Exporting /tony on the Control Workstation . . . . . .
. . . . . . . . . . .
Example of Output from lssrc -g nfs Command
. . . . . .
Extract from amd.log File after amd_start -f Command
. . . . . .
Extract from amd.log When Filesystem Is Not Exported
. . . . . . . . . . . . . . . . . . . . . . . . .
Example of /.rhosts File
setup_authent Script Flow Chart (1/7) . . . . . . . . . . . . . . . . .
setup_authent Script Flow Chart (2/7) . . . . . . . . . . . . . . . . .
setup_authent Script Flow Chart (3/7) . . . . . . . . . . . . . . . . .
setup_authent Script Flow Chart (4/7) . . . . . . . . . . . . . . . . .
setup_authent Script Flow Chart (5/7) . . . . . . . . . . . . . . . . .
setup_authent Script Flow Chart (6/7) . . . . . . . . . . . . . . . . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
107
110
111
121
123
124
129
131
132
133
135
139
140
141
143
148
149
155
160
167
167
173
177
178
195
196
197
199
200
206
210
215
216
217
218
218
219
219
220
221
221
222
223
223
223
224
224
224
226
229
230
231
232
233
234
This soft copy for use by IBM employees only.
107.
108.
109.
110.
111.
112.
113.
114.
115.
116.
117.
118.
119.
120.
121.
122.
123.
124.
125.
126.
127.
128.
129.
130.
131.
132.
133.
134.
135.
136.
137.
138.
139.
140.
141.
142.
setup_authent Script Flow Chart (7/7)
. .
install_cw Script Flow Chart (1/3)
. .
install_cw Script Flow Chart (2/3)
. .
install_cw Script Flow Chart (3/3)
setup_server Script Flow Chart (1/23)
setup_server Script Flow Chart (2/23)
setup_server Script Flow Chart (3/23)
setup_server Script Flow Chart (4/23)
setup_server Script Flow Chart (5/23)
setup_server Script Flow Chart (6/23)
setup_server Script Flow Chart (7/23)
setup_server Script Flow Chart (8/23)
setup_server Script Flow Chart (9/23)
setup_server Script Flow Chart (10/23)
setup_server Script Flow Chart (11/23)
setup_server Script Flow Chart (12/23)
setup_server Script Flow Chart (13/23)
setup_server Script Flow Chart (14/23)
setup_server Script Flow Chart (15/23)
setup_server Script Flow Chart (16/23)
setup_server Script Flow Chart (17/23)
setup_server Script Flow Chart (18/23)
setup_server Script Flow Chart (19/23)
setup_server Script Flow Chart (20/23)
setup_server Script Flow Chart (21/23)
setup_server Script Flow Chart (22/23)
setup_server Script Flow Chart (23/23)
rc.switch Script Flow Chart (1/8) . . .
rc.switch Script Flow Chart (2/8) . . .
rc.switch Script Flow Chart (3/8) . . .
rc.switch Script Flow Chart (4/8) . . .
rc.switch Script Flow Chart (5/8) . . .
rc.switch Script Flow Chart (6/8) . . .
rc.switch Script Flow Chart (7/8) . . .
rc.switch Script Flow Chart (8/8) . . .
. . . . . . . . . . .
The SDR Structure
. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
Figures
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
271
xi
This soft copy for use by IBM employees only.
xii
SP PD Guide
This soft copy for use by IBM employees only.
Tables
1.
2.
3.
4.
5.
6.
7.
 Copyright IBM Corp. 1996
/spdata Filesystem Directories . . . . . . . .
Components of the PSSP Install Image . . .
. . . .
Output Terms of the lslpp Command
Components and Sizes of the PSSP PTFset11
NIM Client Definition Information . . . . . . .
Cabling - SP Switch versus HiPS . . . . . . .
. . . . .
Configuration File Field Definitions
16
17
. 24
. 28
. 55
. 98
190
. . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
xiii
This soft copy for use by IBM employees only.
xiv
SP PD Guide
This soft copy for use by IBM employees only.
Preface
Problem determination and problem solving on the RS/6000 SP can be difficult
because the malfunction may imply the involvement of several components
within AIX and the POWERparallel System Support Programs.
This redbook describes each SP component and helps you understand how they
are related to one another. It gives a comprehensive explanation of processes
occurring within the SP system and provides an approach to diagnosis and
problem solving.
For example, we describe how you can use the error log facility to handle
AIX-related problems. For RS/6000 SP-specific problems, we show how you can
use the PSSP component log files to solve them. All SP log information is
located at /var/adm/SPlogs, and all PSSP components use this directory
structure to store debugging information; the internal file structure and syntax
are specific to each component.
The redbook also includes appendices with useful reference material about
RS/6000 SP script files, the SDR structure, and how to change IP addresses and
hostnames for the SP.
This redbook is a valuable tool for system administrators and other technical
support personnel who deal with SP problems. It is also useful for those who
want a more comprehensive understanding of RS/6000 SP components.
How This Redbook Is Organized
This redbook contains 295 pages. Most of the chapters can be read individually,
except for Chapter 5, “System Partitioning,” for which Chapter 4, “The Switch”
is a prerequisite.
This redbook is organized as follows:
•
Chapter 1, “Overview”
This chapter gives a brief overview of the main SP components. It explains
how these components make up the system and which of them are specific
to the RS/6000 SP. Experienced SP readers do not need to read this chapter.
•
Chapter 2, “The Installation Process”
This chapter covers the kind of problems that are frequently found when the
system administrator is installing or customizing PSSP components. Typical
problems with PSSP scripts, NIM components, and customization steps are
covered here.
•
Chapter 3, “Kerberos”
Kerberos provides authentication services that allow certain distributed
services within the SP system, or between it and other workstations, to
secure control access to their facilities. This chapter explains the Kerberos
concepts and how the components work together. It also covers the
common problems that the Kerberos administrator faces, and gives some
procedures to deal with them.
 Copyright IBM Corp. 1996
xv
This soft copy for use by IBM employees only.
•
Chapter 4, “The Switch”
Most of the Switch-related problems require a clear understanding of the
Switch components. This chapter explains those components and gives
examples about configuration and topology files. Using these examples, the
chapter explains how to handle Switch problems and how to interpret the
Switch log files. This chapter also prepares the reader for Chapter 5, which
requires a good understanding of the Switch components.
•
Chapter 5, “System Partitioning”
This chapter covers System Partitioning in a way that will enable the reader
to understand how all the key components fit together, and give an
understanding of how to carry out problem determination based on this
information. It is essential that the reader fully understands the information
laid out in Chapter 4 before beginning to read these details about System
Partitioning.
•
Chapter 6, “Error Logging”
This chapter describes the error logging facilities provided by the PSSP
components, and how these facilities interface with the standard AIX error
logging “errlog” mechanism. This chapter also includes a description of
how to customize the errlog to provide specific notifications that are not part
of the standard set of notifications provided for the PSSP components.
•
Chapter 7, “Isolating Problems on the SP System”
The RS/6000 SP provides several tools that help to identify and isolate
problems. In this chapter, these tools will be used, along with the Symptom
Index in Chapter 3 of the Diagnosis and Messages Guide , GC23-3899 to help
to isolate problems. Once the problems are isolated, the procedures
explained in the previous chapters can be applied.
•
Chapter 8, “Producing a System Dump”
AIX allows you to generate Memory System Images, called dumps , that can
be analyzed at a later time. Sometimes, under error conditions, these
dumps are generated automatically by the operating system. This facility is
present in the Control Workstation and in the nodes. This chapter explains
how to generate system dumps and how to handle them using standard SP
tools.
•
Chapter 9, “User and Services Management”
This chapter briefly describes some of the components of User and Service
Management, such as File Collection, Amd, Print Services, and NTP. It also
describes how to diagnose and handle common problems with these
components.
•
Appendix A, “RS/6000 SP Script Files”
Many of the SP tasks are carried out by script files. This appendix provides
flow charts for the main PSSP scripts, which can be used as a reference for
problem determination.
•
Appendix B, “The SDR Structure”
The SDR is the core of the SP configuration data management. The
structure consists of files, processes, and commands that allow you to
retrieve information. Its structure is shown in this appendix as a reference
for those who want to know more about its components and how they are
interrelated.
xvi
SP PD Guide
This soft copy for use by IBM employees only.
•
Appendix C, “IP Address and Hostname Changes for the SP”
The IP and Hostname changing on the nodes or on the Control Workstation
is one of the most difficult tasks faced by the administrator. This appendix
provides a procedure that allows you to perform painless and successful IP
and Hostname changing by giving some advice and an easy-to-follow
procedure.
The Team That Wrote This Redbook
This redbook was produced by a team of specialists from around the world
working at the International Technical Support Organization Poughkeepsie
Center.
Marcelo R. Barrios is an SP Project Leader at the International Technical
Support Organization, Poughkeepsie Center. He writes extensively and teaches
IBM classes worldwide on all areas of RS/6000 SP. Before joining the ITSO one
year ago, Mr. Barrios worked as an assistant professor in the Electronic
Department of Santa Maria University, Valparaiso, Chile. In 1993, he joined to
IBM as a Marketing Specialist in the RS/6000 Unit, IBM Chile.
Richard Wagner is a AIX Software Specialist in the RS/6000 Software Support
Center Mainz, IBM Germany. He joined IBM in 1989 and worked in RS/6000 SP
support supporting the RS/6000 BOS software. During the last 10 months he has
focused on the RS/6000 SP products. His expertise has been gained by working
closely with customers resolving installation and post-installation issues. He has
written extensively on the SP Switch. A special “thanks” is extended to
Richards′s colleagues in the AIX Support Center, Mainz, for covering the work
while Richard was writing the redbook.
Andy Hoiles is a Senior AIX Systems Specialist in the RS/6000 Support Center,
IBM UK Ltd. He joined IBM in 1989 and began supporting the RS/6000 software
in 1992. During the last 18 months he has focused on RS/6000 SP products and
his expertise has been gained by working closely with customers resolving
installation and post-installation issues.
Sunil Jain is an Advisory IT Specialist in Sydney, Australia. He is a certified AIX
Support Professional and CNE. He has 18 years experience in the computer
industry. He holds a Post Graduate (M.Sc) degree in Operations Research from
University of Delhi. His area of expertise includes AIX (on RS/6000 and SP),
LAN/WAN and communications/networking products. He has written extensively
on LAN backup/recovery, EDI Implementation and SP Problem Determination.
Tony Schlee is an Advisory Systems Engineer at IBM South Africa. He has 8
years UNIX experience. He has worked for IBM since 1992 with AIX on the
RS/6000.
Thanks to the following people for their invaluable contributions to this project:
Endy Chiakpo
International Technical Support Organization, Poughkeepsie Center
John Lobbes
RS/6000 SP Support Center, Poughkeepsie
Preface
xvii
This soft copy for use by IBM employees only.
Comments Welcome
We want our redbooks to be as helpful as possible. Should you have any
comments about this or other redbooks, please send us a note at the following
address:
redbook@vnet.ibm.com
Your comments are important to us!
xviii
SP PD Guide
This soft copy for use by IBM employees only.
Chapter 1. Overview
The flexibility of the RS/6000 SP plays a very important role when the customer
has to choose between a conventional RISC machine, such as a Uniprocessor or
Symmetric Multiprocessor, and a Massively Parallel Processor. However, this
flexibility works against the situation if the customer tries to manage it as a
conventional system.
We have to understand the philosophy behind the system to realize that there
are many features which make the RS/6000 SP unique. And, although it runs AIX
like any other RS/6000 machine, it has special pieces of hardware and software
code that need special attention to support and manage them.
1.1 RS/6000 SP: Hardware and Software
Although RS/6000 SP is built with standard AIX and RS/6000 parts, it has its own
hardware components and special software to make managing it easier.
There are three hardware components that make the RS/6000 SP different from
conventional RISC machines:
•
The Control Workstation
•
The Frame
•
The High Performance Switch
These components are integrated into the RS/6000 SP environment by the
POWERparallel System Support Programs.
1.1.1 The Control Workstation
The Control Workstation (CW) is the console for the RS/6000 SP, but the CW is
not merely a console. It allows you to manage the system as if it was a single
unit, regardless how many nodes you have 1. However, you will not get the same
functionality you have in a standard RS/6000 console, because you are managing
a Parallel System, and therefore, you are managing multiple systems at once.
The CW is a standard RS/6000 machine, but not all the models are supported as
Control Workstations.
Note: See POWER Parallel Service Bulletin N ° 11 for more information about
using supported RS/6000 models as Control Workstations.
Usually, the CW has at least two connections to the frame; this is shown in
Figure 1 on page 2.
1
This ability has often been referenced as Single System Image .
 Copyright IBM Corp. 1996
1
This soft copy for use by IBM employees only.
Figure 1. Control Workstation Connected to the SP Frame
The serial link connects the CW with the Supervisor Card into the Frame. In this
way, the CW can manage and monitor every major hardware event produced
either by the Frame itself or by the nodes. Each node has a Node Supervisor
Card which is connected to the Frame Supervisor Card, as shown in Figure 2 on
page 3. The new Supervisor Card is able to connect a second CW as a backup
Control Workstation by using the HACWS software option for the POWERparallel
System Support Programs.
Note: More information about HACWS can be found in High Availability on SP ,
SG24-4742.
The Ethernet network (called SP Ethernet) connects each node and the CW.
Usually this network is dedicated to SP traffic only, therefore you should install a
different network adapter to pass user applications traffic.
1.1.2 The Frame
All the hardware information flows from the Frame to the CW through the Serial
Link. In this way, the CW is able to detect hardware failures in the nodes or in
the Frame, and take actions over hardware components.
However, the CW uses the Ethernet to recognize when the nodes are “alive,” not
just powered on, but up and running. Communications with the nodes is handled
by the hardware daemon (called hardmon), which sends small packages called
heartbeat packages through the TCP/IP stack to get in contact with the nodes.
When the nodes are up and running, the hardware monitor sets the host
responds variable from the SDR to “1” for each node.
At this time, the hardware monitor can use only the SP Ethernet to send
heartbeat packages, which reduces this network to a single point of failure. But
2
SP PD Guide
This soft copy for use by IBM employees only.
in future releases, the SP will be able to send heartbeat packages over any
existing network that connects the nodes and the CW.
Figure 2. Supervisor Cards
The Frame contains redundant power supplies; if one power supply fails, another
takes over. The Frame is also designed for concurrent maintenance; each node
can be removed and repaired without interrupting operations on the other nodes.
1.1.3 The High Performance Switch
The High Performance Switch is one of the most unique pieces of hardware and
software developed for the RS/6000 SP. The hardware portion of the switch
provides a low latency and high bandwidth of communication between nodes.
Each node is connected to the High Performance Switch by the Switch Adapter,
as shown in Figure 3 on page 4.
Chapter 1. O v e r v i e w
3
This soft copy for use by IBM employees only.
Figure 3. The High Performance Switch
As you can see in Figure 3, each node is connected to one chip port, and there
are eight chips per switch board. Each chip has eight ports, four external ports
connecting the nodes, and four internal ports connected to the mirror chips.
This topology gives each node four different routes to communicate with another
node. Therefore, each node has four possible ways to reach another node, and
it could use all of the routes together to have a very high bandwidth.
The software portion of the switch provides the device drivers , the processes and
the commands needed to use and manage the switch. These components will
be covered later on this book.
The Switch has the ability to partition, which creates separate and non-disrupting
environments. In this way, each partition can be seen and managed as a
separate SP system. This topic will be covered in more detail in the next
chapter.
1.2 Problem Determination
Basically, there are two kinds of problems encountered on the RS/6000 SP:
those related to AIX and those related to the POWERparallel System Support
Programs. For those related to AIX, the approach to solve them is the standard
AIX way, which means you can use errlog and trace facilities to find the problem.
For those problems specific to the RS/6000 SP, each PSSP component usually
provides log files and tools to solve them. All the log information is located on
/var/adm/SPlogs . The directory structure is shown in Figure 4 on page 5.
4
SP PD Guide
This soft copy for use by IBM employees only.
Figure 4. SP Error Log Structure
All the PSSP components use this directory structure to write their debugging
information. The internal file structure and the syntax is specific to each
component.
When you have problems on the RS/6000 SP, it is sometimes difficult to
determine the source of the problem, especially when the problem or
malfunctioning involves several components within AIX and PSSP. One of the
most difficult things to do is to isolate the problem to one component. Most of
the problems have clear symptoms that point in the right direction, but
sometimes there are problems with symptoms that are not clear enough to
signal which component is causing it. For instance, if a command like this:
# dsh -w sp21n01
fails and says that it could not be authenticated on node sp21n01 due to a
kerberos ticket problem, the offensive component is clear. But if you enter this
command:
# SDRGetObjects SP
and you get nothing, the problem could imply several components, including
hardware failures.
Problem determination and problem solving on SP are difficult tasks to perform
without the right documentation and procedures. Even good documentation is
not always enough to fix a problem. In order to be successful, it is necessary to
understand all of the SP components and realize how they are related to one
another.
This book addresses that problem, by giving a comprehensive explanation to the
processes occurring within the SP components and providing an approach to
solve SP problems. Each component has its own chapter, and all of them are
self-contained. The appendixes included cover those extensive parts that are
Chapter 1. O v e r v i e w
5
This soft copy for use by IBM employees only.
not considered suitable to include in a chapter but are useful as reference
material.
6
SP PD Guide
This soft copy for use by IBM employees only.
Chapter 2. The Installation Process
Installing the RS/6000 SP system includes installing both hardware and software.
Before RS/6000 SP system hardware and software are installed, a detailed plan
should be created. For details of RS/6000 SP site planning, refer to RS/6000 SP:
Site Planning , GC23-3905.
Details of RS/6000 SP hardware installation are covered in Volume 1: Installation
and CE Operations , GC23-3903.
Details of RS/6000 SP software planning and installation procedures are covered
in RS/6000 SP: System Planning , GC23-3902 and in RS/6000 SP: Installation
Guide , GC23-3898.
References to other RS/6000 SP hardware and software manuals can be found in
IBM RS/6000 Scalable POWERparallel Systems Library , GC23-3868.
For details on the installation of RS/6000 SP, refer to RS/6000 SP: Installation
Guide , GC23-3898, Chapter 2, “Installing and Configuring the RS/6000 SP
System.” For important tips, in an easy-to-use cookbook format, see RS/6000
Scalable POWERparallel Systems: PSSP Version 2 Technical Presentation ,
SG24-4542, Chapter 3, “Installing and Configuring the SP System.”
For the purpose of this book, we assume that detailed site planning has been
carried out, RS/6000 SP hardware has been correctly installed, and RS/6000 SP
software planning has already completed. We are now ready to install RS/6000
SP software. This chapter deals with explaining checkpoints at various stages of
the PSSP software install process and provides tips to resolve general problems.
2.1 Major Steps in Installing and Configuring RS/6000 SP Software
This chapter follows RS/6000 SP: Installation Guide , GC23-3898, Chapter 2.
“Installing and Configuring the RS/6000 SP System,” which explains each of the
installation steps in detail. Therefore, this chapter should be read if you need
tips to solve or avoid installation problems, or if you need to understand various
checkpoints in the install process. Following are the major checkpoints in the
installation of the RS/6000 SP system.
1. Setting up the Control Workstation
2. Authentication services
3. The install_cw script
4. The setup_server script
5. Installing the nodes
6. Post-install customizations
The following section discusses the diagnostics for each of these steps.
 Copyright IBM Corp. 1996
7
This soft copy for use by IBM employees only.
2.2 Prepare the Control Workstation
This section is covered in steps 0 through 11, in the Installation Guide and in
sections 3.1, 3.2.1, and 3.2.2 in RS/6000 SP: PSSP Version 2 Technical
Presentation , SG24-4542.
Completing steps 0 through 11, means that the following have been successfully
achieved:
1. AIX has been successfully installed with paths properly defined in .profile for
the administrator and other users.
2. All network connections have been made. Hostnames, IP addresses, and
netmasks have been correctly defined. All IP addresses are able to ping
successfully.
3. RS-232 control lines have been configured on the Control Workstation for the
frame.
4. Space for SP data has been defined (/spdata filesystem).
5. AIX 4.1.4 LPP images have been copied to /spdata/sys1/install/lppsource.
6. PSSP install images have been copied to /spdata/sys1/install/pssplpp and
renamed as pssp.installp, and inutoc script has been run.
7. Basic AIX mksysb image bos.obj.ssp.41 has been installed under
/spdata/sys1/install/images.
8. PSSP software has been installed on the Control Workstation.
9. The required PTF set has been installed.
Any problems that you experience to this point will be AIX software- or
hardware-related. (You have not yet encountered &sp. software.) Refer to AIX
documentation for resolution tips. The following sections cover some general
problems that occur while setting up the Control Workstation and how to resolve
them. Additional information has also been provided to prevent problems.
2.2.1 PSSP Paths
Incorrect paths (or the absence of correct paths) can result in various problems
and wasted time during and after installation. Immediately after installing your
Control Workstation with AIX and LPPs, create a .profile file in your root
directory. Figure 5 on page 9 is an example of a .profile file.
8
SP PD Guide
This soft copy for use by IBM employees only.
PATH=/usr/lpp/ssp/rcmd/bin:
PATH=$PATH:/usr/lpp/ssp/bin:
\
/usr/lpp/ssp/kerberos/bin:/usr/local
PATH=$PATH:/usr/bin:/etc/:/usr/sbin:/usr/ucb
PATH=$PATH:/usr/dt/bin:/usr/lpp/X11/bin:/sbin:
PATH=$PATH:$HOME/bin:/sbin:/bin
MANPATH=/usr/lpp/ssp/man:/u/loadl/man:/usr/man
ENV=/.kshrc
export PATH MANPATH ENV
if [ ! ″$DT″ ]
then
if [ -s ″$MAIL″ ]
then echo ″$MAILMSG″
fi
fi
Figure 5. Sample of a Portion of .profile File
AIX 4.1.4 comes with Common Desktop Environment (CDE), and many customers
decide to use this. AIX provides a sample dtprofile under
/usr/dt/config/sys.dtprofile.
/usr/dt/config/sys.dtprofile is a factory-default file and will be unconditionally
overwritten upon subsequent installation. Before making changes to the file,
copy it to the configuration directory /etc/dt/config.
The sys.dtprofile file is copied to $HOME/.dtprofile the first time a user logs into
the desktop. Any lines in sys.dtprofile located between “SYSPROFILE COMMENT
START” and “SYSPROFILE COMMENT END” are filtered out during the copy.
Your $HOME/.dtprofile is read each time you log in to the Common Desktop
Environment (CDE) and is the place to set or override desktop environment
variables for your session. Environment variables set in $HOME/.dtprofile are
made available to all applications on the desktop. The desktop will accept either
sh or ksh syntax for the commands in $HOME/.dtprofile.
By default, the desktop does not read your standard $HOME/.profile or
$HOME/.login files. This can be changed by uncommenting the
DTSOURCEPROFILE variable assignment at the end of this file. The desktop
reads .profile if your $SHELL is “sh” or “ksh,” or .login if your $SHELL is “csh.”
Here is an example of a sample .dtprofile.
DTSOURCEPROFILE=true
For more details, read the text under /usr/dt/config/sys.dtprofile.
Chapter 2. The Installation Process
9
This soft copy for use by IBM employees only.
2.2.2 AIX Software Components
The RS/6000 you are using as the Control Workstation (CWS) for RS/6000 SP
System must have the following software installed:
•
AIX Version 4.1 Base Operating System
•
TCP/IP
•
NFS
•
NIM file sets
Figure 6 shows the lslpp command used to check the base operating system
runtime environment components that are installed on your Control Workstation.
#
lslpp -l bos.rte
Fileset
Level State
Description
---------------------------------------------------------------------Path: /usr/lib/objrepos
bos.rte
4.1.4.0 COMMITTED Base Operating System Runtime
Path: /etc/objrepos
bos.rte
4.1.4.0
COMMITTED
Base Operating System Runtime
Figure 6. Minimum Required BOS and Runtime Environment Components
Figure 7 shows the command to check Network Install Manager (NIM)
components that are installed on your Control Workstation. If it does not list all
of the required components, then install the missing NIM components from the
AIX install media before proceeding further.
#
lslpp -l ″bos.sysmgt.nim.*″
Fileset
Level State
Description
----------------------------------------------------------------------Path: /usr/lib/objrepos
bos.sysmgt.nim.client
4.1.4.0 COMMITTED Network Install Manager Client Tools
bos.sysmgt.nim.master
4.1.4.0 COMMITTED Network Install Manager Master Tools
bos.sysmgt.nim.spot
4.1.4.0 COMMITTED Network Install Manager SPOT
Path: /etc/objrepos
bos.sysmgt.nim.client
4.1.4.0 COMMITTED Network Install Manager Client Tools
Figure 7. Minimum Required Components of Network Install Manager (NIM)
Figure 8 on page 11 shows the command used to check networking bundles that
are installed on your Control Workstation. If it does not list all of the required
components, then first install the missing components from the AIX install media
before proceeding further.
10
SP PD Guide
This soft copy for use by IBM employees only.
#
lslpp -l ″bos.net.*″
Fileset
Level State
Description
----------------------------------------------------------------------Path: /usr/lib/objrepos
bos.net.nfs.client
4.1.4.0 COMMITTED Network File System Client
bos.net.nfs.server
4.1.0.0 COMMITTED Network File System Server
bos.net.tcp.client
4.1.4.0 COMMITTED TCP/IP Client Support
bos.net.tcp.server
4.1.4.0 COMMITTED TCP/IP Server
bos.net.tcp.smit
4.1.4.0 COMMITTED TCP/IP SMIT Support
Path: /etc/objrepos
bos.net.nfs.client
bos.net.tcp.client
bos.net.tcp.server
4.1.4.0
4.1.4.0
4.1.4.0
COMMITTED
COMMITTED
COMMITTED
Network File System Client
TCP/IP Client Support
TCP/IP Server
Figure 8. Minimum Required Components of Base Networking Software
2.2.3 Disk Space Requirements
Check that you have enough disk space on the Control Workstation. (You need
about 2 to 4 GB of free disk space).
Figure 9 shows the command to check free physical partitions (PPs) on rootvg.
In this example, there are 1852 free PPs (7408 megabytes) available under the
rootvg volume group on the Control Workstation.
#
lsvg rootvg
VOLUME GROUP:
VG STATE:
VG PERMISSION:
MAX LVs:
LVs:
OPEN LVs:
TOTAL PVs:
STALE PVs:
ACTIVE PVs:
rootvg
active
read/write
256
12
11
5
0
5
VG IDENTIFIER:
PP SIZE:
TOTAL PPs:
FREE PPs:
USED PPs:
QUORUM:
VG DESCRIPTORS:
STALE PPs
AUTO ON:
000081007414db91
4 megabyte(s)
2166 (8664 megabytes)
1852 (7408 megabytes)
314 (1256 megabytes)
3
5
0
yes
Figure 9. Output of lsvg rootvg Command to Check Disk Space
2.2.4 RS-232 Control Lines Diagnostics
Each frame in the RS/6000 SP system requires a serial port on the Control
Workstation to accommodate an RS-232 connection between them. As there is
only one frame in the testing environment, only one RS-232 line is needed to be
setup on the Control Workstation. This could be achieved by the smit tty or the
mkdev command. SMIT is the recommended method. Here is the command that
SMIT constructs:
# mkdev -c tty -t ′ tty′ -s ′ rs232′ -p ′ sa0′ -w ′ s1′
The hardmon daemon that executes on the Control Workstation uses the RS-232
line to each frame to poll the frame to check the state of the hardware within the
frame. If the RS-232 line is not configured or the RS-232 connection is missing,
then hardmon will not be able to poll the frame. Accordingly, the client
commands spmon and hmmon will not be able to get the current or changing state
Chapter 2. The Installation Process
11
This soft copy for use by IBM employees only.
of the hardware. The splogd daemon, which is also a client of the hardware
monitor daemon, will not be able to log any changes in hardware state.
2.2.5 Changing IP Addresses and Hostnames
The Control Workstation, in our examples, has a Token Ring and an Ethernet
adapter card. Each of these two adapter cards is configured using smit mktcpip.
SMIT built up the following commands:
# /usr/sbin/mktcpip -h′ sp2tr0′ -a′9.12.0.37′ -m′255.255.255.0′ \
-i′ tr0′ -g′9.12.0.32′ -r′16′ -s′ ′
# /usr/sbin/mktcpip -h′ sp2cw0′ -a′9.12.20.99′ -m′255.255.255.0′ \
-i′ en0′ -t′ bnc′ -s′ ′
tr0 is configured first, followed by en0 . This is done to make en0 the primary
interface to the Control Workstation with hostname sp2cw0 .
After configuring the en0 and tr0 interfaces, IP addresses and host names for
nodes and Ethernet interfaces on the switch are defined. This is done based on
the worksheets which were filled in after proper planning. AIX stores all host
names and IP addresses in an ASCII file host under directory /etc. Figure 10 on
page 13 shows the /etc/hosts file.
12
SP PD Guide
This soft copy for use by IBM employees only.
127.0.0.1
loopback localhost
# CWS Ethernet/TR interfaces
9.12.20.99
sp2cw0 sp2en0
9.12.0.37
sp2tr0
# sp2 nodes
9.12.20.1
sp2n01
9.12.20.2
sp2n02
9.12.20.3
sp2n03
9.12.20.4
sp2n04
9.12.20.5
sp2n05
9.12.20.6
sp2n06
9.12.20.7
sp2n07
9.12.20.8
sp2n08
9.12.20.9
sp2n09
9.12.20.10
sp2n10
9.12.20.11
sp2n11
9.12.20.12
sp2n12
9.12.20.13
sp2n13
9.12.20.14
sp2n14
9.12.20.15
sp2n15
9.12.20.16
sp2n16
# sp2 switches
9.12.6.1
sp2sw01
9.12.6.2
sp2sw02
9.12.6.3
sp2sw03
9.12.6.4
sp2sw04
9.12.6.5
sp2sw05
9.12.6.6
sp2sw06
9.12.6.7
sp2sw07
9.12.6.8
sp2sw08
9.12.6.9
sp2sw09
9.12.6.10
sp2sw10
9.12.6.11
sp2sw11
9.12.6.12
sp2sw12
9.12.6.13
sp2sw13
9.12.6.14
sp2sw14
9.12.6.15
sp2sw15
9.12.6.16
sp2sw16
Figure 10. /etc/hosts File on the Control Workstation
2.2.5.1 Verify Control Workstation Interfaces
Verify that the Ethernet adapter has been properly configured by pinging its IP
address. A successful ping means that the adapter has been correctly
configured. If there are problems pinging the IP address of the Ethernet adapter,
then check for conflicting IP addresses, improper netmask values, or hardware
problems. /etc/hosts may be a good place to look for conflicting IP addresses or
host names. Refer to AIX TCP/IP documentation for details on how to resolve
name resolution or routing problems. Figure 11 on page 14 shows a sample
output of a successful ping.
Chapter 2. The Installation Process
13
This soft copy for use by IBM employees only.
/>
ping 9.12.20.99 -c 1
PING 9.12.20.99: (9.12.20.99): 0 data bytes
8 bytes from 9.12.20.99: icmp_seq=0 ttl=255
----9.12.20.99 PING Statistics---1 packets transmitted, 1 packets received, 0% packet loss
Figure 11. Output of a Successful Ping
It is important to plan the IP addressing scheme and hostnames before starting,
because changing them later after configuring your network could become a
major problem. There are procedures to change IP addresses and hostnames if
required, but this adds extra steps and complications, in some cases. Refer to
Appendix C, “IP Address and Hostname Changes for the SP” on page 273 for a
procedure to change IP addresses or hostnames for the SP nodes and Control
Workstation after initial installation and configuration. This procedure has been
tested in the lab environment based on the /etc/hosts file for name resolution.
This procedure has not been tested in other environments.
2.2.6 Maximum Number of Processes
As the AIX 4.1 default, the maximum number of processes allowed per user is
limited to 40. (This limit does not apply to a root user.) The possible values
range from 40 to 131072. Any increase in this number will take effect
immediately. Any decrease in this number will not become effective until the
next system boot.
Installing your RS/6000 SP system as a root user means that your system will
not affected by this limit. However, it is a good idea to increase this value,
based on your application requirements now, to cater to later requirements.
This will ensure that non-root users running various applications later during
production environment will not be limited by the default limit of 40 processes
per user.
As an example, the following command changes the maximum number of
processes allowed per user to 256. (Remember, this value needs to be set up to
cater to your environment.)
# chdev -l sys0 -a maxuproc=′256′
2.2.7 Number of Licensed Users
Check and rectify the number of licenses that you have bought for AIX 4.1 from
IBM. By default, you will have two users licensed on your Control Workstation.
Any changes will be effective after system reboot. Use smit fastpath smit
chlicense or command line syntax:.
The following example shows how you can change the number of licensed users
to 64. This is only an example, and the actual value depends on what you have
bought from IBM.
# chlicense -u′ 6 4 ′
14
SP PD Guide
This soft copy for use by IBM employees only.
2.2.8 Tunable Values
After the initial installation of RS/6000 SP system, the network tunable values are
set to AIX 4.1 defaults. Change these values to the optimum values for SP
systems. This is achieved by setting no -o commands in tuning.cust file under
tftpboot directory. When the Control Workstation is rebooted, rc.sp script will
check for the existence of /tftpboot/tuning.cust file and run it if it exists. Refer to
2.11, “Node Customization Problems” on page 69 for details of post-installation
customization steps.
Note: /etc/rc.sp does not exist yet. It will be created after the installation of
PSSP software.
2.2.9 /spdata Directory Structure
You need to create a filesystem for SP data. You may create this filesystem
under rootvg or another volume group. IBM recommends a separate volume
group for this purpose. Here are some simple reasons for this recommendation:
•
Independence from root volume group
•
Speedy mksysb of the rootvg
•
Performance
•
Ease of managing programs and data in separate volume groups
Figure 12 shows the directory structure of /spdata filesystem.
Figure 12. /spdata Directory Structure
Chapter 2. The Installation Process
15
This soft copy for use by IBM employees only.
Here is the brief description of the main directories of /spdata filesystem:
Directories
Description
/spdata/sys1
Main directory for SDR, SP monitor, log
management, partition layout files and
installation.
/spdata/sys1/install
Main directory for PSSP installation.
/spdata/sys1/install/lppsource
Location of required AIX 4.1 file sets.
/spdata/sys1/install/images
Location of AIX system backup (mksysb)
images.
/spdata/sys1/install/pssp
Location of NIM configuration data files.
/spdata/sys1/install/pssplpp
Location of all PSSP and SP system file
sets.
/spdata/sys1/sdr
Location of the SDR files.
/spdata/sys1/sdr/archives
In this directory are stored the archives
of the SDR.
/spdata/sys1/sdr/defs
Location of the header files for SDR
classes.
/spdata/sys1/sdr/partitions
Location of the partition classes. There
is one subdirectory for each partition.
/spdata/sys1/sdr/system
Location of the systemwide SDR
classes.
/spdata/sys1/syspar_configs
Location of the topology files.
/spdata/sys1/ucode
Location of the microcode.
/spdata/sys1/spmon
Location of the System Monitor files
(hmacls and hmthresholds).
/spdata/sys1/vsd
Location of the VSD files.
/spdata/sys1/logtables
Location of samples of service collection
table for different PSSP components.
/spdata/sys1/err_methods
Location of the error notification
methods.
Table 1. /spdata Filesystem Directories
Directories under /spdata/sys1/install are manually created before the PSSP
install process is started. The installation process will require lppsource,
images, pssp and pssplpp directories under /spdata/sys1/install. Any deviation
from these names will result in installation failure. Also ensure that these
directories have the permission of rwxr-sr-x.
Other directories and information under them is created by the install process.
2.2.10 Install PSSP on the Control Workstation
Table 2 on page 17 provides a brief overview of various components of PSSP
software, what the minimum required options are, and also what is
recommended by IBM to be installed. Our recommendations will be overridden
by your requirements.
16
SP PD Guide
This soft copy for use by IBM employees only.
Parallel
Partition
Switch
Recommended
Minimum
Component
Option
Authentication
Server
ssp.authent
X
X
Monitoring
the SP
ssp.basic
X
X
SP User
Commands
ssp.client
X
X
Switch Device
Driver
ssp.css
X
Documentation
ssp.docs
X
System
Monitor GUI
ssp.gui
Resource
Manager
ssp.jm
Public Domain
S/W
ssp.public
Sysctl
ssp.sysctl
SP
Management
Tools
ssp.sysman
X
Partitioning
Files
ssp.top
X
X
X
X
X
X
X
X
X
Table 2. Components of the PSSP Install Image
2.2.10.1 Minimal PSSP Installation
For a minimum installation the following components are required:
•
Code for installing and monitoring the SP system (ssp.basic)
•
SP user commands (sp.client)
•
System monitor GUI (ssp.gui)
•
Sysctl (ssp.sysctl)
Other components may be required based on your environment.
If you are using MIT Version 4 or AFS authentication services, then ssp.authent is
not required. For an RS/6000 SP authentication server, you must have
ssp.authent .
If you have a High Performance Switch or an SP Switch, then you have to install
the Switch Device Driver on your nodes. It is part of ssp.css .
Chapter 2. The Installation Process
17
This soft copy for use by IBM employees only.
If you plan to partition your SP system, then you need the predefined partition
files included under ssp.top .
If you are using parallel applications, then you need Resource Manager (ssp.jm) .
You may leave out ssp.public code .
If you are not sure of what you require, then you may install all options of the
PSSP install image on your workstation.
Running smit install_latest creates the following command:
/usr/lib/instl/sm_inst installp_cmd -T iems -L -q -a -d \
′ / spda/install/pssplpp/pssp.installp′ -o ′ all_licensed′ \
′ -c′ ′ -N′ ′ -g′ ′ -X′
2.2.11 PSSP 1.2
The following are some PSSP 1.2 considerations:
•
AIX Version 3.2.5
AIX Version 3.2.5 provides support for PSSP 1.2. Customers should upgrade
to AIX Version 4.1 in order to get the benefits of enhanced features of PSSP
2.1. Customers can then have partitions for AIX Version 3.2.5 running PSSP
2.1, while testing their applications under AIX Version 4.1 partitions.
Note: Customers need to fully understand what is involved in upgrading
their Control Workstation to AIX Version 4.1. They also need to create AIX
3.2.5-based partitions before actually starting the upgrade.
•
First Implementation of PSSP 1.2
PSSP 1.2 was IBM′s first implementation of POWERparallel System Support
Programs (PSSP) software. This level of PSSP requires AIX Version 3.2.5.
PSSP 1.2 is still supported by IBM developers and Support Centers.
PTFset23 is the latest level of PTF available for PSSP 1.2. PTFset23 should
be installed, because it resolves various known defects and also provides
some enhancements.
•
Field Experiences and Demands
Based on customers′ experiences in the field with PSSP 1.2 and customers′
requests for enhanced features, PSSP Release 2 was made available in 1995.
The new software fixes the defects that were identified under PSSP 1.2.
2.2.12 PSSP 2.1
The following are some PSSP 2.1 considerations:
•
AIX 4.1.4
PSSP 2.1 allows the SP system to exploit the benefits of AIX Version 4.1 and
to prepare for future hardware and software technological advances.
•
PSSP 2.1
This is the latest PSSP code available. PSSP 2.1 has provided major
enhancements and extra features over PSSP 1.2. Some of these are
discussed here.
•
Enhancements
−
18
SP PD Guide
System partitioning
This soft copy for use by IBM employees only.
System partitioning supports several system partitions running AIX
Version 3.2.5 or AIX Version 4.1 to run as logical systems within a single
SP system. This provides the ability to test new software, isolate
workloads to dedicated resources, and run different applications on
different partitions as required by different segments of the business.
−
Node isolation from the switch network
Node isolation provides a mechanism to isolate nodes from the switch
fabric for repair, replacement, or reboot, without affecting end users,
applications, or switch traffic on the remainder of the SP system or
system partition.
−
Installation support
Improved installation support is provided by the use of the AIX Version 4
Network Installation Management (NIM).
−
Improved log management
Log management provides a single point of control to assist customers
in configuring, archiving, and maintaining various system logs on
individual nodes. Customers can also specify additional logs that may
be used by their applications.
−
Enhanced security features
PSSP 2.1 increased the maximum ticket life to 30 days for Kerberos, and
enhancements to address any host by any of its host names.
•
VSD performance improvements
With standard VSD, database applications could only stripe data across
multiple disks associated with one node. With Hashed Shared Disk (HSD),
the capability to stripe across nodes has been added, returning more data to
the application faster than serial reads.
•
Engineering and scientific computing
The following software products have been upgraded with new functions to
extend support for engineering and scientific computing:
−
IBM Parallel Environment for AIX Version 2.1 provides support for
parallel applications on AIX Version 4.1.
−
IBM Parallel ESSL for AIX 4.1.4 improves performance of engineering and
scientific applications on the RS/6000 SP Systems.
−
IBM PVMe for AIX supports parallel execution of applications on AIX
version 4.1.4.
2.2.13 Changes from PSSP 1.2 to PSSP 2.1
The following are the changes made in going from AIX Version 3.2.5 to AIX
Version 4.1:
•
/usr client and /usr server
/usr client and /usr server, which were supported under AIX Version 3.2.5,
are not supported under the new version.
•
Primary dump device
Primary dump space, which was defined as /dev/hd7 under AIX Version
3.2.5, is now defined as paging space (/dev/hd6) under the new version.
Chapter 2. The Installation Process
19
This soft copy for use by IBM employees only.
However, this only applies to the Control Workstation. The SP nodes
continue using /dev/hd7 as the primary dump device.
The following are the changes that occur when going from PSSP 1.2 to PSSP 2.1:
•
Installation over DIX
Support for installation over Ethernet type DIX has been added.
•
Customization file
firstboot.cust is now script.cust.
•
Tuning customization
A new tuning customization file called tuning.cust has been added.
•
PSSP image
bos.obj.ssp.325 is now bos.obj.ssp.41.
•
mksysb image
/usr/sys/inst.images/ssp is now /spdata/sys1/install/images.
Under PSSP 1.2, the mksysb image could be a symbolic link. This is no
longer the case. Network Installation Management (NIM) exports the file.
The mksysb image must be a regular file in the /spdata/sys1/install/images
directory on the Control Workstation.
•
ssp.installp
ssp.installp is now pssp.installp.
•
spbootins
spbootins now has:
•
−
A diagnosis option, -r diag
−
New syntax for the -h option
Remote Diagnosis Support has been added in PSSP 2.1.
2.2.14 PSSP Software Strategy
The PSSP updates and fixes are available on a regular basis from IBM as PTF
sets. Some of the PSSP concepts and terminology are described as follows:
•
PSSP PTFs are available as full replacement PTFs or delta replacement
PTFs:
−
Full replacement PTFs
Full replacement PTFs means that all of the associated codes in the
affected component have been shipped in the PTF.
−
Delta replacement PTFs
Delta replacement PTFs means that only the changed files from this PTF
and prior delta replacement PTFs have been shipped in the PTF. These
PTFs will have the last full replacement PTF as a prerequisite.
•
PSSP PTF can be obtained through:
FixDist
You can obtain information about required PTFs from the Web at
http://www.rs6000.ibm.com/software/Pubs/sp_secure/status. This page also
contains a hyperlink to the US Fixdist server to download the required PTFs.
20
SP PD Guide
This soft copy for use by IBM employees only.
If you do not have direct access to the IBM network, then you may get these
PTFs from the IBM Support Center by calling them and providing them with
requirements, media type, delivery address, and urgency.
•
Latest PSSP PTF
This is always changing, so a good place to look at it is in the Web at
http://www.rs6000.ibm.com/software/Pubs/sp_secure/status/, where you will
find the latest PTF sets available, as well as a matrix describing the PSSP
components affected by these PTFs.
2.2.15 Obtaining PSSP PTFs Using FixDist
Figure 13. Obtaining PSSP PTFs Using FixDist
The easiest way to obtain AIX fixes and PSSP fixes is to use the tool FixDist.
There are several servers available around the world that mirror the latest set of
available PTFs:
•
Canada
rwww.aix.can.ibm.com
204.138.188.126
•
Germany
www.ibm.de
192.109.81.2
•
Japan
fixdist.yamato.ibm.co.jp
202.32.4.20
•
Nordic
ftp.nordic.ibm.com
193.12.214.80
•
United Kingdom ftp.europe.ibm.com
193.129.186.2
•
United States
198.17.57.66
service.software.ibm.com
The FixDisk front end program shown in Figure 13 is also available on these
servers.
Chapter 2. The Installation Process
21
This soft copy for use by IBM employees only.
2.2.16 Determining Software Service Level
It is important to find out what software service level you have because you may,
for example, need it to report a problem to the IBM Support Center. The support
staff needs this information to check various databases to ascertain if such a
problem is already known on the software service level in question.
Specifying the current software service level while ordering PTFs dramatically
reduces the PTF package size and installation time. There are at least two ways
to find out your software service level:
•
lslpp command
The lslpp command has various flags to provide service level information, as
the following example shows:
# lslpp -l  grep ssp
•
ssp.authent
ssp.basic
ssp.clients
ssp.css
ssp.docs
ssp.gui
ssp.jm
ssp.public
ssp.sysctl
ssp.sysman
ssp.top
ssp.authent
ssp.basic
ssp.clients
ssp.css
ssp.jm
ssp.sysctl
ssp.sysman
ssp.top
2.1.0.2
2.1.0.10
2.1.0.5
2.1.0.8
2.1.0.4
2.1.0.6
2.1.0.2
2.1.0.2
2.1.0.2
2.1.0.7
2.1.0.2
2.1.0.0
2.1.0.10
2.1.0.0
2.1.0.8
2.1.0.0
2.1.0.0
2.1.0.7
2.1.0.0
COMMITTED
COMMITTED
COMMITTED
COMMITTED
COMMITTED
COMMITTED
COMMITTED
COMMITTED
COMMITTED
COMMITTED
COMMITTED
COMMITTED
COMMITTED
COMMITTED
COMMITTED
COMMITTED
COMMITTED
COMMITTED
COMMITTED
SP Authentication Server
SP System Support Package
SP Authenticated Client
SP Communication Subsystem
SP man and info files
SP System Monitor Graphical
SP Job Manager Package
Public Code Compressed
SP Sysctl Package
Optional System Management
SP Communication Subsystem
SP Authentication Server
SP System Support Package
SP Authenticated Client
SP Communication Subsystem
SP Job Manager Package
SP Sysctl Package
Optional System Management
SP Communication Subsystem
Using PSSP Program Directory
The structure is /usr/lpp/ssp/ < p r o d u c t > / < l e v e l > , where product is an SSP
product such as ssp.basic , and level is the level of service such as 2.1.0.10.
You may traverse through the PSSP program directory for individual PSSP
components and get to the fixdata file, as shown in the following example:
22
SP PD Guide
This soft copy for use by IBM employees only.
# cd /usr/lpp/ssp/ssp.basic/2.1.0.10
# ls -las
total 40
4 drwxr-xr-x 3 root
4 drwxr-xr-x 3 root
4 -r--r--r-- 1 root
4 drwxr-xr-x 3 root
4 -rw-r--r-- 1 root
12 -rw-r--r-- 1 root
# view ssp.basic.fixdata
system
system
system
system
system
system
512
512
1902
512
15
9630
May
Apr
Apr
Apr
Apr
Apr
14
24
23
23
23
23
15:43
18:30
17:13
17:15
17:13
17:13
.
..
README
inst_root
productid
ssp.basic.fixdata
fix:
name = IX56314
abstract = Vanderbilt PTF
type = f
filesets = ″ssp.authent:2.1.0.2\n\
ssp.basic:2.1.0.10\n\
ssp.clients:2.1.0.5\n\
ssp.csd.cmi:2.1.0.1\n\
ssp.csd.hsd:2.1.0.2\n\
ssp.csd.vsd:2.1.0.4\n\
ssp.css:2.1.0.8\n\
ssp.docs:2.1.0.4\n\
ssp.gui:2.1.0.6\n\
ssp.jm:2.1.0.2\n\
ssp.public:2.1.0.2\n\
ssp.sysctl:2.1.0.2\n\
ssp.sysman:2.1.0.7\n\
ssp.top:2.1.0.2\n\
″
symptom = ″″
fix:
name = IX54093
abstract = Slot attrs to Frame class missing on install
″ssp.basic.fixdata″ [Read only] 529 lines, 9630 characters
The lslpp command lists software products. It displays information about
installed filesets or fileset updates. The FilesetName parameter is the name of a
software product. The FixID (also known as PTF or program temporary fix ID)
parameter specifies the identifier of an update to an AIX 3.2 formatted fileset.
When only the -l (lowercase L) flag is entered, the lslpp command displays the
latest installed level of the fileset specified for the AIX 3.1 and 4.1 formatted
filesets. The base level fileset is displayed for the AIX 3.2 formatted filesets.
When the -a flag is entered along with the -l flag, the lslpp command displays
information about all installed filesets for the FilesetName specified.
The -I (uppercase i) flag combined with the -l (lowercase L) flag specifies that the
output from the lslpp command should be limited to base level filesets.
The -d, -f, -h, -i, -l (lowercase L), -L, and -p flags request different types of output
reports.
The -a, -c, -J, -O, and -q flags specify the amount and format of the information
that is displayed in the report.
The default value for the FilesetName parameter is all , which displays
information about all installed software products. Pattern matching characters,
such as * (asterisk) and ? (question mark), are valid in the ProductName and
FixID parameters. You do not have to enclose these characters in ′ ′ (single
quotes). However, using single quotes prevents you from searching the contents
of your present directory.
Chapter 2. The Installation Process
23
This soft copy for use by IBM employees only.
Much of the output from the lslpp command is understandable without an
explanation. Other fields contain data that needs to be defined. The following
table defines terms used in several of the output fields of the lslpp command:
Output field
Term
Definition
APPLIED
The specified fileset is installed on the
system. The APPLIED state means that the
fileset can be rejected with the installp
command, and the previous level of the
fileset can be restored. This state is only
valid for 4.1 fileset updates and 3.2
migrated filesets.
APPLYING
An attempt was made to apply the
specified fileset, but it did not complete
successfully, and cleanup was not
performed.
BROKEN
State
COMMITTED
The specified fileset is installed on the
system. The COMMITTED state means
that a commitment has been made to this
level of the software. A committed fileset
update cannot be rejected, but a
committed fileset base level and its
updates (regardless of state) can be
removed or deinstalled by the installp
command.
OBSOLETE
The specified fileset was installed with an
earlier version of AIX (for example, 3.2),
but it has been replaced by a repackaged
(renamed) newer version. Some of the
files that belonged to this fileset have been
replaced by versions from the repackaged
fileset.
of the fileset
COMMITTING
SP PD Guide
An attempt was made to commit the
specified fileset, but it did not complete
successfully, and cleanup was not
performed.
REJECTING
An attempt was made to reject the
specified fileset, but it did not complete
successfully, and cleanup was not
performed.
APPLY
An attempt was made to apply the
specified fileset.
Action
CLEANUP
An attempt was made to perform cleanup
for the specified fileset.
taken for the
fileset
COMMIT
REJECT
24
The specified fileset or fileset update is
broken and should be reinstalled before
being used.
An attempt was made to commit the
specified fileset.
An attempt was made to reject the
specified fileset.
This soft copy for use by IBM employees only.
Output field
Status
history
results of
install actions
Term
Definition
BROKEN
The fileset was left in a broken state after
the specified action.
CANCELED
The specified action was canceled before it
completed.
COMPLETE
NONE
The commitment of the fileset has
completed successfully.
This fileset update has not been installed
but a superseding update has (applicable
to AIX 3.2 formatted fileset updates only).
Table 3. Output Terms of the lslpp Command
Examples:
1. To list the installation state for the most recent level of installed filesets for
all of the bos.rte filesets, enter:
lslpp -l ″bos.rte.*″
2. To list the installation state for the base level and updates for the fileset
bos.rte.filesystem, enter:
lslpp -La bos.rte.filesystem
3. To list the installation history information of all the filesets in the bos.net
software package, enter:
lslpp -ha ′ bos.net.*′
4. To list the names of all the files of the bos.rte.lvm fileset, enter:
lslpp -f bos.rte.lvm
2.2.17 Working with PSSP PTFs
PTFs are an essential part of PSSP installation. By installing correct levels of
PSSP PTFs, you ensure that the PSSP software enhancements and fixes for
known problems are incorporated in the PSSP code on your Control Workstation
and in your nodes.
When dealing with PTFs, you should be aware of the following:
•
Check smit.log
Always use smit when you are dealing with PTFs.
The smit command will give you the status of completion in the smit.log file.
After installation has completed (or FAILED), check the smit.log thoroughly
and identify any instances of FAILED messages. Determine which
components, if any, have FAILED to install. The smit command provides
information as to why the install or upgrade has failed, and what you need to
do to fix the problem. Take actions required to rectify the problem. Use of
the smit command can be very helpful in determining why the problem
occurred, which part is affected, and how to fix the problem.
•
PTF prerequisites, corequisites, and if-requisites
Always ensure that the PTF you are installing has all the prerequisites,
corequisites and if-requisites. If you are missing any prerequisites, then PTF
install will fail. smit.log will provide information as to what was missing and
what to do next.
Chapter 2. The Installation Process
25
This soft copy for use by IBM employees only.
•
README file
Always read the README file under directory /usr/lpp/ssp for information
about various PSSP components, including product information, installation
information, restrictions, advisories, important APAR information, and other
allied information. This can be very useful information in resolving problems
even before they arise. Here is the listing of the /usr/lpp/ssp/README
directory:
#
cd /usr/lpp/ssp/README
# ls -l
total 152
-rw-r--r-1 bin
bin
-rw-r--r-1 bin
bin
-rw-r--r-1 bin
bin
-rw-r--r-1 bin
bin
-rw-r--r-1 bin
bin
-rw-r--r-1 bin
bin
-rw-r--r-1 bin
bin
-r--r--r-1 bin
bin
-r--r--r-1 bin
bin
-rw-r--r-1 bin
bin
-r--r--r-1 bin
bin
-rw-r--r-1 bin
bin
-rw-r--r-1 bin
bin
-rw-r--r-1 bin
bin
-rw-r--r-1 bin
bin
-rw-r--r-1 bin
bin
4110
3454
5372
127
247
2945
3608
1524
402
5907
1863
1386
3403
2186
1487
116
Apr 9 06:45 ssp.authent.README
Apr 12 14:31 ssp.authent.README.IX56801
Apr 9 07:05 ssp.basic.README
Apr 9 09:39 ssp.basic.README.IX53006
Apr 9 09:39 ssp.basic.README.IX54269
Apr 9 07:05 ssp.basic.README.IX56314
Apr 9 06:49 ssp.clients.README
Apr 9 07:00 ssp.css.README
Apr 9 07:05 ssp.css.README.IX56314
Apr 9 07:00 ssp.docs.README
Apr 9 06:45 ssp.gui.README
Apr 9 06:44 ssp.jm.README
Apr 9 06:44 ssp.public.README
Apr 9 09:34 ssp.sysctl.README
Apr 9 06:44 ssp.sysman.README
Apr 9 09:39 ssp.top.README.IX53362
README files also exist for some products under /usr/lpp/ssp/ product/level ,
particularly after you have already installed some PTFs for that component.
For example, here is the listing of the /usr/lpp/ssp/ssp.basic/2.1.0.10 directory
after installing PTFset11:
#
cd /usr/lpp/ssp/ssp.basic/2.1.0.10
# ls -las
4 drwxr-xr-x
3 root
system
512 Apr 23 17:16
4 drwxr-xr-x
3 root
system
512 Apr 24 18:30
4 -r--r--r-1 root
system
1902 Apr 23 17:13
4 drwxr-xr-x
3 root
system
512 Apr 23 17:15
4 -rw-r--r-1 root
system
15 Apr 23 17:13
12 -rw-r--r-1 root
system
9630 Apr 23 17:13
•
.
..
README
inst_root
productid
ssp.basic.fixdata
Stop processes (if required)
Always read the PSSP component′s README file under
/usr/lpp/ssp/README before installing any PTF that affects a component. If,
for example, you do not read ssp.authent.README.IX56801 under the
README directory and install PTFset11, which also updates ssp.authent , then
the installation will fail as if the Kerberos daemon were still running.
If you try to install PTF for ssp.authent after the setup_authent step, then the
PTF installation will fail. You must not have kerberos, kadmind, or hardmon
running when installing the PTF for ssp.authent . If you do, smit.log will show
the following:
26
SP PD Guide
This soft copy for use by IBM employees only.
ERROR:
kadmind is running.
kerberos is running.
Because of this, the PTF installation cannot go on.
Stop daemons kerberos, kadmind and hardmon.
Install the PTF.
Then restart those three daemons.
For further information, see the ssp.authent.README.IX56801 that
accompanies this PTF.
update: Failed while executing the ssp.authent.pre_u script.
0503-464 installp: The installation has FAILED for the ″usr″ part
of the following filesets:
ssp.authent 2.1.0.2
installp: Cleaning up software for:
ssp.authent 2.1.0.2
Finished processing all filesets.
(Total time:
11 mins 42 secs).
Execute the following steps before re-installing the PTF:
#
#
#
#
#
chitab ″kadm:2:off:/usr/lpp/ssp/kerberos/etc/kadmind -n″
chitab ″kerb:2:off:/usr/lpp/ssp/kerberos/etc/kerberos″
telinit 2
stopsrc -s hardmon
smit install_selectable_all
If the installation fails, check smit.log and search for FAIL. Take corrective
action as required.
After the successful installation of the PTF, you have to perform the following
steps to change inittab file and start the kadmind, kerberos, and hardmon
daemons.
#
#
#
#
•
chitab ″kadm:2:respawn:/usr/lpp/ssp/kerberos/etc/kadmind
chitab ″kerb:2:respawn:/usr/lpp/ssp/kerberos/etc/kerberos
telinit 2
startsrc -s hardmon
Loss of sysman configuration files after installing PTFSet11
PTFset11 for RS/6000 SP Version 2 Release 1 is a full replacement PTF set
and will therefore replace some configuration files that you have on your
system. To retain the contents of these files, you need to save and then
restore them after the installation of PTF Set 11. The following is a list of the
ssp.sysman 2.1.0.7 files that will be replaced:
/usr/lpp/ssp/filec/file.collections
/usr/lpp/ssp/filec/sup/sup.admin/list
/usr/lpp/ssp/filec/sup/sup.admin/lock
/usr/lpp/ssp/filec/sup/sup.admin/prefix
/usr/lpp/ssp/filec/sup/sup.admin/refuse
/usr/lpp/ssp/filec/sup/sup.admin/supperlock
/usr/lpp/ssp/filec/sup/user.admin/list
/usr/lpp/ssp/filec/sup/user.admin/lock
/usr/lpp/ssp/filec/sup/user.admin/prefix
/usr/lpp/ssp/filec/sup/user.admin/refuse
/usr/lpp/ssp/filec/sup/user.admin/supperlock
/usr/lpp/ssp/filec/sup/node.root/list
/usr/lpp/ssp/filec/sup/node.root/lock
Chapter 2. The Installation Process
27
This soft copy for use by IBM employees only.
/usr/lpp/ssp/filec/sup/node.root/prefix
/usr/lpp/ssp/filec/sup/node.root/refuse
/usr/lpp/ssp/filec/sup/node.root/supperlock
/usr/lpp/ssp/filec/sup/power_system/list
/usr/lpp/ssp/filec/sup/power_system/lock
/usr/lpp/ssp/filec/sup/power_system/prefix
/usr/lpp/ssp/filec/sup/power_system/refuse
/usr/lpp/ssp/filec/sup/power_system/supperlock
You should never run base level PSSP software by itself. At minimum, you
should be on PTFset4 or PTFset8. PTFset11 is the latest full replacement set that
can be installed on base PSSP 2.1 software level. Various defects have been
fixed and feature enhancements have been made on the PSSP base level of
software. PTFs are available through Support Organizations, or online through
fixdist .
Table 4 lists various components and their sizes of PTFset11 available at the
time this document was written.
Component
Size
ppe.poe.2.1.0.8
2063360
ppe.vt.2.1.0.4
1428480
ssp.authent.2.1.0.2
380928
ssp.basic.2.1.0.10
17014784
ssp.clients.2.1.0.5
1904640
ssp.csd.cmi.2.1.0.1
158720
ssp.csd.hsd.2.1.0.2
190464
ssp.csd.vsd.2.1.0.4
317440
ssp.css.2.1.0.8
6221824
ssp.docs.2.1.0.4
10412032
ssp.gui.2.1.0.6
1777664
ssp.jm.2.1.0.2
1333248
ssp.public.2.1.0.2
12348416
ssp.sysctl.2.1.0.2
539648
ssp.sysman.2.1.0.7
1111040
ssp.top.2.1.0.2
984064
Table 4. Components and Sizes of the PSSP PTFset11
2.3 Authentication Services Diagnostics
To initialize your primary authentication server on the RS/6000 SP Control
Workstation, you need to run the setup_authent command from the command line
on your Control Workstation. The Kerberos administrator needs to define a
kerberos master key, principal name, instance, password for your principal and
instance, and then again password before kerberos initialization for your
principal.instance can start. Step-by-step instructions of your interaction with
setup_authent is explained in the SP Installation Guide. Details of what
setup_authent does is explained in Chapter 3, “Kerberos” on page 71 under
3.4.1, “setup_authent” on page 74.
28
SP PD Guide
This soft copy for use by IBM employees only.
Path Problems
If running setup_authent gives the error setup_authent not
found, then check your path for setup_authent. You can use
which setup_authent command to get the correct path to
setup_authent. Include correct kerberos paths in your
.profile file or use full path.
Here are the paths required by kerberos that you should
put in your .profile file:
/usr/lpp/ssp/rcmd/bin
/usr/lpp/ssp/kerberos/bin
/usr/lpp/ssp/kerberos/etc
/usr/lpp/ssp/bin
Kerberos Problems
For tips to solve various kerberos problems, refer to 3.8,
“Solving Problems” on page 82 in Chapter 3, “Kerberos”
on page 71. You may also take a look at the
setup_authent script flow chart in A.1, “The setup_authent
Script” on page 229.
2.4 install_cw Diagnostics
Before you proceed further, ensure that you are authenticated as a valid user
with a valid ticket. If required, run the kinit command to get a valid ticket from
RS/6000 SP authentication services specifying the administrative principal name
that was used when authentication was set up.
The full path of this script is /usr/lpp/ssp/bin/install_cw.
install_cw runs on the Control Workstation and does the following:
•
Configures the Control Workstation
•
Executes /usr/lpp/ssp/inst_root/ssp.basic.post_i
After PTF 12, this script is not called directly.
There was a dependency on ssp.basic.post_i after installation which caused
several problems. It was most easily seen when a node had been restored
from a mksysb in which the variable RM_INST_ROOT is set to yes in the
bosinst.data on the system from which the mksysb was taken. This caused
inurid -r to be run when the system was restored.
pssp_script calls ssp.basic.post_i during install and fails to customize the
node properly after installation.
The pssp_script has been changed to call post_process and post_sysctl. The
post_process and post_sysctl files are equivalent to the post_i
ssp.basic.post_i and ssp.sysctl.post_i files, respectively, and they are located
in the /usr/lpp/ssp/install/bin directory.
•
Installs smit panels
•
Configures SDR
•
Updates /etc/services and /etc/inittab
•
Starts SP daemons
•
Creates /spdata/sys1/spmon/hmacls file with the administrator′s ACL for
hardmon
•
Configures default system partition
Chapter 2. The Installation Process
29
This soft copy for use by IBM employees only.
•
For a complete flow chart of what install_cw does, refer to Appendix A.2,
“The install_cw Script” on page 236.
Figure 14 shows a sample output of running the install_cw script.
13
entries added.
0 entries deleted.
0 entries updated.
0513-071 The sdr.sp2cw0 Subsystem has been added.
making SRC object ″hb.sp2cw0″ at system level PSSP-2.1
0513-071 The hb.sp2cw0 Subsystem has been added.
making SRC object ″hr.sp2cw0″
0513-071 The hr.sp2cw0 Subsystem has been added.
0513-085 The hardmon Subsystem is not on file.
0513-084 There were no records that matched your request.
0513-071 The hardmon Subsystem has been added.
13 entries added.
0 entries deleted.
1 entries updated.
0513-085 The splogd Subsystem is not on file.
0513-084 There were no records that matched your request.
0513-071 The splogd Subsystem has been added.
0513-059 The splogd Subsystem has been started. Subsystem PID is 15102.
0513-059 The sysctld Subsystem has been started. Subsystem PID is 16390.
Figure 14. Output of Running install_cw Script
Figure 15 shows what gets added to the /etc/inittab file from running the
install_cw script.
sdrd:2:once:/usr/bin/startsrc
-g sdr
sp:2:wait:/etc/rc.sp > /dev/console 2>&1
hardmon:2:once:/usr/bin/startsrc -s hardmon
hr:2:once:/usr/bin/startsrc -g hr
hb:2:once:/usr/bin/startsrc -g hb >/dev/null 2>/dev/console
splogd:2:once:/usr/bin/startsrc -s splogd
Figure 15. Portion of /etc/inittab That Gets Added from Running install_cw
Figure 16 shows what gets added to /etc/services from running the install_cw
script.
hardmon
sdr
heartbeat
8435/tcp
5712/tcp
4893/udp
Figure 16. Portion of /etc/services That Gets Added from Running install_cw
2.4.1 Problems Solving
If you have problems running the install_cw script, check following:
30
SP PD Guide
•
/usr/lpp/ssp/bin should be exported in your PATH.
•
You should be logged on as a valid authenticated user of the system
management commands.
This soft copy for use by IBM employees only.
•
You should have a valid ticket from the RS/6000 SP authentication services.
Use the klist command to check authentication and kinit command to
request authentication (if required).
•
If the install_cw script does not complete successfully, then refer to Appendix
A.2, “The install_cw Script” on page 236 to see a detailed flowchart of the
working of this script and identify where the script has failed. Diagnosis and
Message Guide , GC23-3899 could provide useful pointers based on the error
message that you received. For example, if the script has failed because
you have not yet completed the kerberos configuration, then you need to
complete the authentication part first.
2.5 Problems with spmon
SP System Monitor refers to four main components:
•
Hardware Monitor
The hardware monitor consists of a set of commands and a daemon to
monitor and control the SP hardware platform
•
SP System Monitor GUI
The SP system monitor graphical user interface (GUI) to the hardware
monitor provides a point-and-click method to view the system status and
interact with the frame, node, and switch controls.
•
Command Line Interface
The spmon, hmmon, hmcmds, s1term, and nodecond commands with their flags
and parameters, provide a way to monitor and control the SP system.
•
Logging daemon
The splogd logging daemon logs SP hardware state changes, reports SP
hardware errors, and provides a state change alert.
Figure 17 on page 32 shows a diagram of a System Monitor, where lines
represent relationships of its different components.
Chapter 2. The Installation Process
31
This soft copy for use by IBM employees only.
Figure 17. Snapshot of System Monitor
The hardware monitor consists of a daemon, named hardmon, and a set of client
commands. The hardmon daemon executes on the Control Workstation and,
using the RS-232 lines to each frame, polls the frames for the state of the
hardware within the frame. The daemon also sends hardware-level commands
to each frame to change the state of the hardware within the frame in some way.
The client commands spmon and hmmon interact with hardmon to obtain the current
or changing state of the hardware.
The client commands spmon and hmcmds also interact with hardmon to change the
state and control the hardware. The SP system monitor GUI issues the spmon
command internally to control and monitor the hardware.
The splogd logging daemon is also a client of the hardware monitor for logging
purposes.
2.5.1 Problems with System Monitor Commands
When you try to run spmon -g on the Control Workstation and the system reports
that spmon: not found., then verify installation, as follows:
•
Make sure that the ssp.basic option of the pssp installp image was installed.
The ssp.basic option provides the system monitoring function.
Run verification tests using smit or the command line to ensure installation
is complete. Use smit as follows:
# smit smoni_verify
or enter the following on the command line:
# /usr/lpp/ssp/bin/spmon_itest
sysmon_itest: Start sysmon installation verification test
32
SP PD Guide
sysmon_itest: Verification Succeeded
This soft copy for use by IBM employees only.
This result indicates that the ssp.basic option is installed.
•
If the verification in the previous step succeeds, then check your PATH
environment variable. You can achieve this by using echo $PATH.
−
Add /usr/lpp/ssp/bin to your PATH or use the full path name with the
command.
2.5.2 Problems Accessing Pulldown Menus of spmon
On the Control Workstation, if you run spmon -g in order to get the graphic
interface of spmon, and the numlock key is on, then you will not be able to access
any menu in spmon by clicking on Files or SP with the mouse. If numlock is off,
spmon works without any problem. When you experience this problem with spmon
with numlock on, you can still access the mwm root menu and aixterms window
menus. This problem is reported under IX50314. This problem was tested on
the ssp.gui.2.1.0.6 level.
2.5.3 System Monitor Displays Blanks Instead of the Expected Information
If the system monitor panels are displaying blanks instead of the expected
information after installation, or if the ControllerResponds indicator on the
system monitor frame environment panel is red, or if the
/var/adm/SPlogs/SPdaemon.log reports that the Frame Controller is not
responding, then do the following:
•
Verify PSSP Installation.
Run verification tests to ensure that installation is complete. You can
achieve this using smit or from the command line. Use smit as follows:
# smit sman_verify
or, from the command line, enter the following:
# /usr/lpp/ssp/bin/SYSMAN_test
HOST: sp2cw0
-----------SYSMAN_test: Verification succeeded
SYSMAN_test: Executing test on all active nodes
HOST: sp2n01
-----------SYSMAN_test: Verification succeeded
HOST: sp2n02
-----------SYSMAN_test: Verification succeeded
HOST: sp2n03
-----------SYSMAN_test: Verification succeeded
.
.
.
.
.
.
HOST: sp2n13
-----------SYSMAN_test: Verification succeeded
HOST: sp2n14
-----------SYSMAN_test: Verification succeeded
SYSMAN_test: The number of nodes that were not tested is 4
This output confirms that your installation is complete.
Chapter 2. The Installation Process
33
This soft copy for use by IBM employees only.
•
Verify the RS-232 connection.
Ensure that the RS-232 line is connected to the correct frame and the correct
serial port on the Control Workstation. Remember that the hardmon daemon
on the Control Workstation requires an RS-232 connection to each frame to
poll the frame for the state of hardware within the frame. Without the RS-232
line, hardmon has no way to check the state of hardware in the frame.
Again, you have the choice of using smit or the command line. Use smit as
follows:
# smit smonc_verify
or, from the command line, enter the following:
# /usr/lpp/ssp/bin/spmon_ctest
sysmon_ctest: Start sysmon configuration verification test
sysmon_ctest: Verification Succeeded
This output confirms that your RS-232 connection is fine.
•
Verify Serial Port speed.
Check the baud rate of the serial port. The System Monitor configures this
for you when it starts. Use the stty command as follows to redirect input
from the correct serial port:
# stty </dev/tty0
speed 19200 baud; -parity clocal
.
.
.
.
-isig -icanon -echo -echoe -echok
In this example, speed 19200 is correct.
•
Check frame configuration.
If the frame information is missing when you use any one of the following
commands, the SDR does not know about the frame. Accordingly, spmon -g
will not be able to start the spmon gui.
You can verify this by using either smit or the command line. Use smit as
follows:
# smit list_frame
or, from the command line, enter the following:
# SDRGetObjects Frame
frame_number tty
1 /dev/tty0
#
frame_type
switch
MACN
sp2cw0
backup_MACN
″″
or
#
# /usr/lpp/ssp/bin/splstdata -f
List Frame Database Information
frame#
tty
frame_type
---------------------------------------1
/dev/tty0
switch
#
The output illustrated confirms that the frame information is available.
34
SP PD Guide
This soft copy for use by IBM employees only.
If you find out that the frame information is missing, you first need to add
frame information, and then reinitialize the SDR. This can be done through
the smit fastpath smit frame_dialog.
•
Check the log for messages.
Check the /var/adm/SPlogs/SPdaemon.log on the control workstation and
take action to address any messages. Look for resource name sphwlog for
SP hardware problems.
May
8 20:03:09 sp2cw0 hardmon[13970]:
LPP=PSSP,Fn=hardmon.c,SID=1.26,L#=260,
hardmon: 0026-874 Unable to determine whether
the Control Workstation is active, inactive, or non-HACWS.
In the /var/adm/SPlogs/SPdaemon.log file on the Control Workstation, there
was no entry with sphwlog . The preceding example is an entry that was
found and is shown here just as an example entry in the log file. The same
messages are also logged under errpt .
−
Check /var/adm/SPlogs/SPdaemon.log for messages containing the word
sphwlog.
−
Perform the following command to check the AIX error log:
# errpt -aN sphwlog
LABEL:
SPMON_INFO101_TR
IDENTIFIER:
3E6F3CE7
Date/Time:
Sequence Number:
Machine Id:
Node Id:
Class:
Type:
Resource Name:
Resource Class:
Resource Type:
Location:
Tue May 7 15:15:07
965
000081007000
sp2cw0
H
UNKN
sphwlog
NONE
NONE
NONE
Description
ELECTRICAL POWER RESUMED
Probable Causes
POWER SUBSYSTEM
User Causes
POWER OFF
Recommended Actions
NONE
Detail Data
DETECTING MODULE
LPP=PSSP,Fn=splogd.c,SID=1.16.1.7,L#=909,
DIAGNOSTIC EXPLANATION
Information; Node 1:8; powerLED; Power is on.
#
This log provides full details of all SP hardware errors.
•
If you cannot figure out the cause of the problem, call the IBM Support
Center.
Chapter 2. The Installation Process
35
This soft copy for use by IBM employees only.
2.5.4 Problems with System Monitor GUI
•
If the spmon command fails to start the System Monitor GUI, you need to
check the following:
−
Verify authorization:
- Run the klist command to verify that the kerberos tickets are not
expired.
- Reissue the kinit command if required.
- Check /spdata/sys1/spmon/hmacls to ensure that the kerberos
principal name and instance for your ID is in this hardware Monitor
ACL file:
sp2cw0 root.admin a
−
sp2cw0 hardmon.sp2cw0 a
1 root.admin vsm
1 hardmon.sp2cw0 vsm
Ensure you have exported DISPLAY:
# echo $DISPLAY
9.12.0.3:0
In this example, DISPLAY is exported correctly to the local display on the
PC with an IP address 9.12.0.3.
•
If an open session failure message window is displayed after opening the
System Monitor GUI, you need to check following:
−
Verify authorization using klist, request authorization using kinit, and
check /spdata/sys1/spmon/hmacls.
−
Check hardware monitor daemon (hardmon):
- Issue the hardware monitor command using an ID that has monitor
authority and a valid ticket-granting ticket from kinit.
Following is an example command to check frame 1, node 1:
# hmmon -Q 1:1
If this command does not work, check the hardmon log
/var/adm/SPlogs/spmon/hmlogfile, where nnn is the Julian date of
when the file was created.
- Check /var/adm/SPLogs/spmon/hmlogfile.nnn
•
If the System Monitor GUI hangs, it could be because of performance
reasons or authorization problems. Check the following:
−
Check performance:
- Check for adequate paging space.
- Check overall CPU utilization.
- Check CPU utilization of hardmon and splogd:
# ps vgc | grep hardmon
# ps vgc | grep splogd
If the CPU utilization rate is very high and cannot be attributed to the
hardmon or logging daemon, then look for other processes which are
consuming the CPU resources. Contact the IBM Support Center if
you cannot resolve the problem.
36
SP PD Guide
This soft copy for use by IBM employees only.
−
Verify authorization through klist.
2.5.5 Logging Problems
•
If the logfile is no longer being updated:
Check the logging daemon:
−
Check that splogd is running.
The following example shows how you can check that splogd is running
using either the lssrc -s or the ps -eaf command:
# lssrc -a  grep splogd
−
splogd
15378 active
#
# ps -eaf  grep splogd
root 15378 5854 0 May 08 - 0:00 /usr/lpp/ssp/bin/splogd
-f /spdata/sys1/spmon/hwevents
root 18408 15248 0 11:22:43 pts/0 0:00 grep splogd
Check /etc/syslog.conf for daemon.notice entry
daemon.notice
/var/adm/SPlogs/SPdaemon.log
−
Check that the /var/adm/SPlogs/SPdaemon.log exists with permissions
rw-r--r--.
−
Check that error record templates for SPMON exist:
# errpt -t | grep SPMON
•
If the logging daemon dies:
−
•
Check for a core dump. If available, run crash to identify the reason for
the core dump. If required, send the core dump and /unix file to the IBM
Support Center for investigation.
If the hardware monitor daemon (hardmon) dies:
−
Check for a core dump. If available, run crash to identify the reason for
the core dump. If required, send the core dump and /unix file to the IBM
Support Center for investigation.
−
Check /var/adm/SPlogs/spmon/hmlogfile.nnn.
2.5.6 Example — Some Nodes Are Missing
This is an example of how to investigate if spmon does not show a node. In this
example, assume node 8 is not showing up.
1. Run splstdata -n. This proves whether or not SDR has information about
this node.
Chapter 2. The Installation Process
37
This soft copy for use by IBM employees only.
# splstdata -n
List Node Configuration Information
node# frame# slot# slots initial_hostname reliable_hostname default_rout
------------------------------------------------------------------------1
1
1
1 sp2n01
sp2n01
9.12.20.99
2
1
2
1 sp2n02
sp2n02
9.12.20.99
3
1
3
1 sp2n03
sp2n03
9.12.20.99
4
1
4
1 sp2n04
sp2n04
9.12.20.99
5
1
5
1 sp2n05
sp2n05
9.12.20.99
6
1
6
1 sp2n06
sp2n06
9.12.20.99
7
1
7
1 sp2n07
sp2n07
9.12.20.99
8
1
8
1 sp2n08
sp2n08
9.12.20.99
9
1
9
1 sp2n09
sp2n09
9.12.20.99
10
1
10
1 sp2n10
sp2n10
9.12.20.99
11
1
11
1 sp2n11
sp2n11
9.12.20.99
12
1
12
1 sp2n12
sp2n12
9.12.20.99
13
1
13
1 sp2n13
sp2n13
9.12.20.99
14
1
14
1 sp2n14
sp2n14
9.12.20.99
15
1
15
1 sp2n15
sp2n15
9.12.20.99
16
1
16
1 sp2n16
sp2n16
9.12.20.99
In this case, SDR has information about node 8.
2. Check /var/adm/SPlogs/spmon and view hmlogfile.nnn.
The following is a listing of the relevant portion of the
/var/adm/SPlogs/SPconfig/node_info file:
/SP/frame/frame1/node7/type/value/97
/SP/frame/frame1/node9/type/value/97
node_info is missing node 8.
3. Try s1term -w 1 8. The following message is received:
s1term: 0026-645 The S1 port in frame 1 slot 8 cannot be accessed.
It either does not exist or you do not have S1 permission.
4. Check the RS-232 cable from node 8 to the switch:
If a cable is loose, securing it will cause spmon to show node 8.
2.5.7 Example — spmon Will Not Start
The actions to be taken will depend on the error message displayed by the
spmon GUI when it fails.
1. Check that the hardmon daemon is running.
38
SP PD Guide
This soft copy for use by IBM employees only.
Figure 18. The hardmon Daemon Is Not Running
ps -eaf  grep hardmon shows that it is running, but another ps -eaf shows it
is continually respawning. fuser /dev/tty0 reconfirms this.
2. Check that the sdr daemon is running by using
lssrc -g sdr or ps -aef  grep sdr
Figure 19. The sdr Daemon Is Not Running
Chapter 2. The Installation Process
39
This soft copy for use by IBM employees only.
If the sdr daemon is not running, enter the following:
startsrc -g sdr
If the problem persists, move on to the next check.
3. Check the /spdata/sys1/spmon/hmacls file.
Figure 20. The hmacls File
In this example, /spdata/sys1/spmon/hmacls has incomplete entries. The
following two lines are missing:
1 root.admin vsm
1 hardmon.sp2cw0 vsm
Even if these lines are added by hand, there may still be a problem starting
spmon. Check for and remove any blank lines.
4. Kill hardmon to respawn it with new information from the
/spdata/sys1/spmon/hmacls file.
After killing hardmon, spmon -g will start okay.
2.6 Problems with Some PSSP Scripts
2.6.1 setup_authent Script
If you have problems running setup_authent script, check the following:
•
PATH
/usr/lpp/ssp/bin should be exported in your PATH.
•
40
SP PD Guide
Name resolution
This soft copy for use by IBM employees only.
For all configured IP interfaces, the name resolution has to be set up
correctly by using the /etc/hosts file or DNS. This also includes interfaces
other than the SP internal Ethernet.
•
Configuration files
In case you are using an existing Kerberos server, make sure the
configuration files /etc/krb.conf and /etc/krb.realms are set up correctly.
Remove these files in case you employ the Control Workstation as a
Kerberos server. The configuration files will be created by setup_authent
according to your Control Workstations hostname, domain name, or both.
There might be cases in which you want to run this script in whole a second
time. You can do this, but be aware that performing this action will destroy the
Kerberos database. Never do this on a running SP system!
1. Remove the Kerberos configuration files and the Kerberos server keytab file.
# rm -i /etc/krb*
rm: Remove /etc/krb-srvtab? y
rm: Remove /etc/krb.conf? y
rm: Remove /etc/krb.realms? y
#
2. Remove the Kerberos master key file and the ticket cache file.
# rm -i /.k /tmp/tkt0
rm: Remove /.k? y
rm: Remove /tmp/tkt0? y
#
3. Remove the Kerberos user database files.
# rm -i /var/kerberos/database/*
rm:
rm:
rm:
rm:
rm:
rm:
rm:
#
Remove
Remove
Remove
Remove
Remove
Remove
Remove
/var/kerberos/database/admin_acl.add? y
/var/kerberos/database/admin_acl.get? y
/var/kerberos/database/admin_acl.mod? y
/var/kerberos/database/principal.dir? y
/var/kerberos/database/principal.ok? y
/var/kerberos/database/principal.pag? y
/var/kerberos/database/slavesave? y
4. Correct any mistakes you have made, for example incomplete name
resolution, and rerun the script:
# setup_authent
5. Make sure you now can login as r o o t . a d m i n @ < R E A L M > and the service
keys for rcmd and hardmon have been created.
Chapter 2. The Installation Process
41
This soft copy for use by IBM employees only.
# kinit root.admin
Kerberos Initialization for ″root.admin″
Password: <password>
# klist
Ticket file:
/tmp/tkt0
Principal:
root.admin@SPCNTL
Issued
Expires
Principal
Jul 17 17:02:51 Aug 16 17:02:51 krbtgt.SPCNTL@SPCNTL
# klist -srvtab
Server key file: /etc/krb-srvtab
Service
Instance
Realm
Key Version
-----------------------------------------------------rcmd
spcntl
SPCNTL
1
hardmon
spcntl
SPCNTL
1
#
6. If you have problems running the setup_authent script, you may use the flow
chart in A.1, “The setup_authent Script” on page 229 and see where this
script is failing. What actions you follow will depend on the error message
you are getting from running the script. However, it is very uncommon for
setup_authent to fail when the entire database has been deleted following the
previous steps.
2.6.2 install_cw Script
If you have problems running the install_cw script, check the following:
•
PATH
/usr/lpp/ssp/bin should be exported in your PATH.
•
Authentication
You should be logged in as a valid authenticated user of the system
management commands.
•
Valid ticket
You should have a valid ticket from the RS/6000 SP authentication services.
Use the klist command to check authentication, and the kinit command to
request authentication (if required).
•
install_cw Flow Chart
If the install_cw script does not complete successfully, refer to the detailed
flow chart of the working of this script in A.2, “The install_cw Script” on
page 236, and identify where the script has failed. SP Diagnosis and
Messages Guide , GC23-3899 could provide useful pointers based on the error
message that you received. For example, if the script has failed because
you have not yet completed kerberos configuration, then you need to
complete the authentication part first.
Figure 21 on page 43 shows what gets added to the /etc/inittab file by running
the install_cw script.
42
SP PD Guide
This soft copy for use by IBM employees only.
sdrd:2:once:/usr/bin/startsrc
-g sdr
sp:2:wait:/etc/rc.sp > /dev/console 2>&1
hardmon:2:once:/usr/bin/startsrc -s hardmon
hr:2:once:/usr/bin/startsrc -g hr
hb:2:once:/usr/bin/startsrc -g hb >/dev/null 2>/dev/console
splogd:2:once:/usr/bin/startsrc -s splogd
Figure 21. /etc/inittab File after Running install_cw Script
The next figure shows what gets added to the /etc/services by running the
install_cw script.
hardmon
sdr
heartbeat
8435/tcp
5712/tcp
4893/udp
Figure 22. /etc/services File after Running install_cw Script
2.7 Restore Control Workstation mksysb
There might be situations in which you have to rerun the script install_cw. For
example, perhaps you have restored a mksysb of the Control Workstation to
recover from the loss of a disk. Each node of the SP and the CWS has a
node_number entry in its ODM (CuAt). This entry gets lost when you restore the
mksysb image on the CWS. There are two different methods you can use to
recreate this entry.
1. Run install_cw. This will create the proper node_number entry for the
Control Workstation in the ODM. This script also performs other actions that
do not affect the configuration of the CWS and which do not need to be run to
recreate the entry in the ODM. For instance, the splogd and hardmon
subsystems are deleted and recreated.
2. The other method is to create the entry in the ODM:
a. Make sure that there is no old entry in the ODM:
# odmdelete -o CuAt -q ″name=sp and attribute=node_number″
b. Copy the template file for the node_number entry to some temporary
disk space:
# cp /usr/lpp/ssp/install/config/cuat.sp /tmp/cuat.sp
c. Edit this file and replace the line containing the attribute value = “ N n N ”
with v a l u e = “ 0 ” , reflecting that the node number of the CWS is “0.”
d. Insert this entry into the ODM:
# ODMDIR=/etc/objrepos odmadd /tmp/cuat.sp
e. Verify that the entry has been created, and remove the temporarily
created file:
Chapter 2. The Installation Process
43
This soft copy for use by IBM employees only.
# odmget -q name=sp CuAt
CuAt:
name = ″sp″
attribute = ″node_number″
value = ″0″
type = ″R″
generic = ″DU″
rep = ″s″
nls_index = 24
# rm /tmp/cuat.sp
2.8 NIM Problems
Network Installation Management (NIM) enables you to centrally manage the
installation of AIX Version 4.1 Base Operating System (BOS) and optional
software on machines with a networking environment.
As part of PSSP 2.1, NIM was introduced as the network installation support for
the RS/6000 SP. NIM is a general AIX product, and its introduction to the SP
environment was intended to centralize and be coherent with the rest of the
RS/6000 products. Most of the NIM commands and options are being hidden by
PSSP scripts and commands, so everyone dealing with SP nodes installation and
customization must deal with NIM.
In this section we cover some of the problems you can face when dealing with
NIM during the installation and customization process.
The Network Install Management (NIM) environment is defined on two
characteristic machine roles: master and client .
NIM Master This role is dedicated to only one machine in the NIM environment.
The NIM master is the single point of administration for NIM
installations. All NIM-related operations are performed on that
machine. Within the RS/6000 SP environment, the machine in the
master role is always the CWS.
NIM Client Systems which become installed from the NIM master have the role
of NIM client. They remain NIM clients unless this role is explicitly
removed. Within the RS/6000 SP environment, nodes were installed
as standalone machines and do not stay NIM clients.
NIM provides two installation types, depending on whether the NIM master or
NIM client is initiating the installation process: pull installation and push
installation. Within the RS/6000 SP environment, only pull installation is
supported.
The NIM concept is modeled by NIM objects. There are several classes of NIM
objects on which different sets of operations can be performed. The following
operations are defined for all kinds of NIM objects:
•
define (creates new NIM objects)
•
change (adds new or changes existing attributes of NIM objects)
•
remove (removes existing NIM objects)
The different NIM object classes are defined as follows:
44
SP PD Guide
This soft copy for use by IBM employees only.
Network Objects
The network object describes the network that can be used for the
installation process. Several network objects can exist at the same
time. Within the RS/6000 SP environment, the network objects name
is spnet.
# lsnim -l spnet
spnet:
class
type
net_addr
snm
Nstate
prev_state
=
=
=
=
=
=
networks
ent
192.168.0.0
255.255.255.0
ready for use
information is missing from this object′ s definition
This network object allows the installation of a node by use of the
RS/6000 SP internal Ethernet.
Machine Objects
The representation of the systems which become installed are
machine objects.
The three types of machine objects are:
•
standalone
•
diskless
•
dataless
NIM client and other information is stored on the master. Within the
RS/6000 SP environment, there is a machine object for each node of
the RS/6000 SP. They will run as .standalone systems after the
installation.
# lsnim -l sshps01
sphps01:
class
type
Cstate
prev_state
Mstate
cpuid
platform
if1
cable_type1
Cstate_result
=
=
=
=
=
=
=
=
=
=
machines
standalone
ready for a NIM operation
BOS installation has been enabled
currently running
002028747000
rs6k
spnet speth01.aixedu 02608CE87C5F ent
bnc
reset
Resource Objects
This class of objects represents resources which are available in the
NIM environment. Resource objects represent files and directories
which are necessary for some NIM operation like the BOS installation
of a NIM client. Several of these resources are allocated to a
machine object depending on the software or the used installation
process.
There are several types of resource objects.
•
lpp_source
•
spot
•
script
•
mksysb
Chapter 2. The Installation Process
45
This soft copy for use by IBM employees only.
•
bosinst_data
•
and so on
The complete list of resources is available in the NIM Installation Guide and
Reference , SC23-2627.
Within the RS/6000 SP environment, the following resource objects are created:
•
lppsource (type lpp_source)
This resource points to the LPPs which are located in the directory
/spdata/sys1/install/lppsource in the RS/6000 SP environment.
# lsnim -l lppsource
•
lppsource:
class
type
server
location
alloc_count
Rstate
prev_state
simages
=
=
=
=
=
=
=
=
resources
lpp_source
master
/spdata/sys1/install/lppsource
1
ready for use
unavailable for use
yes
psspspot (type spot)
# lsnim -l psspspot
•
psspspot:
class
type
version
server
location
alloc_count
Rstate
prev_state
release
if_supported
if_supported
if_supported
if_supported
if_supported
if_supported
if_supported
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
resources
spot
04
master
/usr
1
ready for use
ready for use
01
rs6k ent
rs6k fddi
rs6k tok
rs6ksmp ent
rs6ksmp tok
rspc ent
rspc tok
noprompt (type bosinst_data)
The noprompt resource defines some of the installation parameters like the
target disks, the installation method (overwrite/migrate) and whether the
TCB (Trusted Computing Base) is used.
# lsnim -l noprompt
noprompt:
class
type
server
location
alloc_count
Rstate
prev_state
=
=
=
=
=
=
=
resources
bosinst_data
master
/spdata/sys1/install/pssp/bosinst_data
1
ready for use
unavailable for use
Here is an example for the noprompt resource which is defined by the file
/spdata/sys1/install/pssp/bosinst_data within the RS/6000 SP environment:
46
SP PD Guide
This soft copy for use by IBM employees only.
# cat /spdata/sys1/install/pssp/bosinst_data
control_flow:
CONSOLE = /dev/tty0
INSTALL_METHOD = overwrite
PROMPT = no
EXISTING_SYSTEM_OVERWRITE = yes
INSTALL_X_IF_ADAPTER = no
RUN_STARTUP = no
RM_INST_ROOTS = yes
ERROR_EXIT =
CUSTOMIZATION_FILE =
TCB = no
INSTALL_TYPE = full
BUNDLES =
target_disk_data:
LOCATION =
SIZE_MB =
HDISKNAME = hdisk0
•
locale:
BOSINST_LANG = en_US
CULTURAL_CONVENTION = en_US
MESSAGES = en_US
KEYBOARD = en_US
psspscript (type script)
The script /spdata/sys1/install/pssp/pssp_script is called at the end of the
installation process of a node. It performs, for instance, the following tasks:
−
Configuration of the network adapters except the css0 adapter.
−
Install additional lpps
−
Call the /tftpboot/tuning.cust script
−
Call the /tftpboot/script.cust script
# lsnim -l psspscript
•
psspscript:
class
type
alloc_count
server
location
Rstate
prev_state
=
=
=
=
=
=
=
resources
script
1
master
/spdata/sys1/install/pssp/pssp_script
ready for use
unavailable for use
mksysb_1 (type mksysb)
This resource defines the location and name of the image to be installed on
the nodes. There is one mksysb resource for each installation image on the
CWS.
# lsnim -l mksysb_1
mksysb_1:
class
type
alloc_count
server
location
Rstate
prev_state
version
release
=
=
=
=
=
=
=
=
=
resources
mksysb
1
master
/spdata/sys1/install/images/bos.obj.ssp.41
ready for use
unavailable for use
4
1
Chapter 2. The Installation Process
47
This soft copy for use by IBM employees only.
Before you install, customize, maintain, or diagnose a node, it is necessary to
allocate the appropriated NIM resource to the machine object. This resource
allocation is done by the setup_server script by calling several NIM commands.
Following is an example of a machine object, called sp21n01, that has been
enabled to be installed. The corresponding allocations have been highlighted to
reflect the additional attributes of the NIM machine object.
#
lsnim -l sp21n01
sp21n01:
class
= machines
type
= standalone
Cstate
= BOS installation has been enabled
prev_state
= ready for a NIM operation
Mstate
= currently running
cpuid
= 002028747000
platform
= rs6k
if1
= spnet speth01.aixedu 02608CE87C5F ent
cable_type1 = bnc
spot
= psspspot
control
= master
lpp_source
= lppsource
bosinst_data = noprompt
script
= psspscript
mksysb
= mksysb_1
boot
= boot
nim_script
= nim_script
2.9 NIM Commands
In some cases, the configuration of the NIM master does not work as smoothly
as displayed so far. In these cases, you have to perform some diagnostic tasks.
NIM offers you a set of commands you can run to do this. A list of some of them
follows:
48
SP PD Guide
lsnim
This command displays information about the NIM environment,
including predefined information, the attributes required for a NIM
Operation, all customized NIM Objects, information on specific NIM
objects and information about resources available to specific NIM
machines.
nim
The nim command performs operations on NIM objects. The type of
operation performed is dependent on the type of object on which this
operation is performed. This means that the type of operation is
different, for instance, on machine and resource objects.
nimclient
The nimclient command is used by workstations that are NIM clients
to pull NIM resources. This command can enable or disable the NIM
master server′s ability to initiate workstation installation and
customization. In the RS/6000 SP environment, this command is not
used. All NIM configurations are performed directly on the CWS.
nimconfig
The nimconfig command initializes the NIM master package. This
includes, for instance, the creation and start of the nimesis process
(SRC-controlled) which is used for communication purposes between
NIM Master and NIM Clients. In the RS/6000 SP environment, this
command is called by the setup_server script.
This soft copy for use by IBM employees only.
niminit
This command configures the NIM client package. Call this
command before you use the command nimclient. If the workstation
has been installed from a NIM master, it is already a NIM client and
this command is not used. There is no need to use this command in
the RS/6000 SP environment.
Let′s have a closer look at the lsnim command and the nim command. These
two commands are basically used for NIM administration purposes once the NIM
master package has been configured.
#
lsnim
master
boot
nim_script
spnet
lppsource
psspspot
noprompt
prompt
psspscript
mksysb_1
sphps01
sphps03
sphps05
sphps06
machines
resources
resources
networks
resources
resources
resources
resources
resources
resources
machines
machines
machines
machines
master
boot
nim_script
ent
lpp_source
spot
bosinst_data
bosinst_data
script
mksysb
standalone
standalone
standalone
standalone
Without any parameters, the command lsnim displays all NIM objects which have
been created on this NIM master.
In the RS/6000 SP environment, we see the previously mentioned resources.
The -l option displays the set of attributes, which are associated with a specific
NIM object.
#
lsnim -l sphps01
sphps01:
class
=
type
=
Cstate
=
platform
=
if1
=
cable_type1
=
prev_state
=
cpuid
=
Mstate
=
Cstate_result =
machines
standalone
ready for a NIM operation
rs6k
spnet speth01.aixedu 02608CE87C5F ent
bnc
BOS installation has been enabled
002028747000
currently running
reset
The meanings of the different attributes follow:
class
This attribute represents the object class. In addition to
machines, there are the classes resource and network.
type
The type attribute defines the machine type. In this case the
workstation is a standalone system. Other possible states are
diskless and dataless. The RS/6000 SP environment supports
only the machine type standalone.
Chapter 2. The Installation Process
49
This soft copy for use by IBM employees only.
Cstate
This attribute defines the control state of the machine. The
possible states are:
•
Ready for NIM operation.
(Required state to perform an operation on an object.)
•
Diskless or dataless boot is enabled.
(This is not relevant in the RS/6000 SP environment.)
•
Diskless resources are being initialized.
(This is not relevant in the RS/6000 SP environment.)
•
Dataless install has been enabled.
(This is not relevant in the RS/6000 SP environment.)
platform
•
Diagnostic boot has been enabled.
•
BOS installation has been enabled.
•
Base operating system installation is being performed.
•
Customization is being performed.
•
Post-install process is being performed.
•
Software maintenance is being performed.
The hardware platform of the system:
•
rs6k Micro Channel-based uniprocessor systems
•
rs6ksmp Micro Channel-based symmetric multiprocessor
systems
•
rspc ISA-bus systems
In the RS/6000 SP environment, only rs6k is relevant.
if1
This attribute specifies the interface to be used for the
installation. It holds the name of the used network resource
spnet , the later host name of the system, the MAC address of
the network adapter that is used for network booting, and the
type of network adapter.
cable_type1
This is bnc or dix in the RS/6000 SP environment.
prev_state
This attribute displays the previous state of the NIM object.
cpuid
Stores the ID of the CPU.
Mstate
This attribute defines the machine state . Possible values are:
•
Currently running
•
Not running
•
In the process of booting
It is not guaranteed that this state always displays the real state
of the system.
Cstate_result
This attribute specifies the result of the last control applied to
this machine object.
The nim command
The nim command is used to perform operations on NIM machine objects.
50
SP PD Guide
This soft copy for use by IBM employees only.
# nim -o <operation> -a <attribute>=<value> ... <object>
# lsnim -O sphps01
sphps01:
define
= define an object
change
= change an object′ s attributes
remove
= remove an object
allocate
= allocate a resource for use
deallocate = deallocate a resource
diag
= enable a machine to boot a diagnostic image
cust
= perform software customization
bos_inst
= perform a BOS installation
maint
= perform software maintenance
reset
= reset an object′ s NIM state
lslpp
= list LPP information about an object
fix_query = perform queries on installed fixes
check
= check the status of a NIM object
reboot
= reboot specified machines
This -O option of the lsnim command is very useful in determining the set of
operations that can be performed on a specific object (the object sphps01 of type
machine , in this case).
define
This operation creates a new NIM machine object. In the RS/6000
SP environment, it is called by setup_server for all nodes which are
known to the SDR.
# nim -o define -t standalone -a if1=′ spnet speth02 10005aa88123′ \
-a cable_type1=dix newhost
This operation creates the standalone NIM machine object newhost.
The NIM Network object spnet must exist at this time. Several
checks are made; for instance, whether the IP address for
hostname speth02 is reachable from the net spnet. Furthermore,
the attribute cable_type1 is a required for Ethernet network objects.
There are other optional attributes for machine objects:
iplrom_emu, cpuid, comments, ring_speed, cable_type, and platform.
The script setup_server uses the attributes platform and cpuid in
addition to the given example.
change
This operation changes the values of attributes.
# nim -o change -a cable_type1=bnc newhost
or
# nim -o change -a comments=″This is a comment...″ newhost
To remove an optional attribute, just let the value for the attribute
void while changing the object.
# nim -o change -a comments= newhost
remove
This operation removes a NIM machine object. Removing machine
objects is successful in case no resources are allocated to that
machine object and its Cstate is Ready for a NIM operation. This
state can be enforced by resetting the object:
# nim -o remove newhost
The script setup_server removes and redefines machine objects, for
instance, in case some of the node-specific information like the
hardware address of the SP Ethernet adapter changes. This
Chapter 2. The Installation Process
51
This soft copy for use by IBM employees only.
change is done when the next boot responds of the involved node
requires a network boot.
allocate
This operation allocates some resources to a machine object.
Sometimes more then one resource must be allocated before an
operation like bos_inst or diag can be performed. The operation
diag, for instance, requires a spot resource to be allocated first.
# nim -o allocate -a spot=psspspot newhost
deallocate
This operation deallocates resources from a machine object. Each
resource owns an allocation counter specifying how often this
resource has been allocated by machine objects. These resources
can be removed only when their allocation counter has the value 0.
This means the resource is not allocated by any machine object.
# nim -o deallocate -a spot=psspspot newhost
diag
This operation performs all configurations necessary to enable a
diagnostic image to be booted at the next netboot time. In the
RS/6000 SP environment this is done by:
# spbootins -r diag -l 3
which changes the boot responds value for node number 3 and
calls setup_server, which allocates the necessary resources
( psspspot) and calls:
# nim -o diag sphps03
cust
This operation is used to install and update software or to execute
scripts on standalone clients. In the RS/6000 SP environment this
operation is not used. It requires the nodes to be configured as
NIM Clients (access to root user granted by entry in .rhosts file on
the node). The following example shows how to install the
Performance Agent software on a workstation. First an lpp_source
must be allocated to the machine object on which the software is to
be installed. The lpp_source must contain the fileset being
installed. Then the installation is performed in the second step:
# nim -o
# nim -o
-a
-a
allocate -a lpp_source=lppsource newhost
cust \
fileset=″perfagent″
installp_flags=″-agX″ newhost
The lpp_source resource is deallocated automatically thereafter.
bos_inst
The operation bos_inst enables a workstation being installed from a
NIM master. Before this operation can be performed successfully,
some resources have to be allocated to the machine object of that
workstation. The resources spot and lpp_source are required. The
resources bosinst_data, image_data, installp_bundle, mksysb, and
script are optional.
# nim -o bos_inst newhost
The script setup_server uses this operation to setup the installation
for RS/6000 SP nodes. Here the additional attributes
no_client_boot and source are used.
# nim -o bos_inst -a source=mksysb -a no_client_boot=yes sphps03
The following list of resources has been allocated prior to the
bos_inst operation in the RS/6000 SP environment: psspspot,
lppsource, noprompt, psspscript and mksysb_1.
52
SP PD Guide
This soft copy for use by IBM employees only.
maint
This operation is used to perform operations on installed software,
such as removing or cleaning up after an interrupted installation. It
is not used in the RS/6000 SP environment because nodes are not
configured as NIM Clients. The following example shows how to
uninstall the Performance Agent software from a workstation.
# nim -o maint -a installp_flags=″-u″ -a filesets=perfagent newhost
reset
This operation is used to reset the Cstate of a machine object back
to Ready for a NIM operation . Resources are not automatically
deallocated. The following example resets the machine object
newhost.
# nim -o reset newhost
lslpp
This operation is used to display all LPPs installed on a
workstation. It is not used in the RS/6000 SP environment because
it would require the nodes to be configured as NIM Clients.
# nim -o lslpp newhost
fix_query
NIM provides the fix_query operation as an interface to the instfix
command to provide the ability to list information about installed
fixes. The fix_query operation can be applied to SPOT resources or
NIM clients. When invoked without any optional attributes,
information about all installed fixes are displayed on the target.
The fixes attribute and fix_bundle resource are available to the
fix_query operation to install particular fixes. This operation is not
used in the RS/6000 SP environment because it would require the
nodes to be configured as NIM Clients.
# nim -o fix_query newhost
check
The operation check performs some basic consistency checks on
the given machine object.
# nim -o check newhost
reboot
This operation is used to reboot workstations. It is not used in the
RS/6000 SP environment because it would require the nodes to be
configured as NIM Clients.
# nim -o reboot newhost
The following list of operations is used by the setup_server script:
define , change , remove , allocate , bos_inst , and diag .
To Start All over Again
If you need to start NIM completely over, you can use this set of commands:
#
nim -o unconfigure master
# installp -u bos.sysmgt.nim.master
# setup_server
To Reset the Machine State
Sometimes you need to reset the state of a machine object after a failed
installation or customization. You can do it in this way:
Chapter 2. The Installation Process
53
This soft copy for use by IBM employees only.
#
nim -Fo reset <machine object>
# nim -o deallocate -a subclass=all <machine object>
Or you can do it by using PSSP commands:
#
spbootins -r disk -l <node number> ...
2.9.1 NIM Diagnostics
Because NIM maintains its own information about the state of the nodes,
separated from the SDR information, you may get inconsistences between these
two SP components, especially when you are trying to install or customize SP
nodes, and NIM does not allocate resources to it. Here is a list of steps you can
follow to check that all the NIM information is consistent with the SDR
information:
•
Reviewing NIM Client Definition:
1. Determine the client′ s NIM master by using:
splstdata -b -l <client_node_number>
Look at the srvr field, which lists the NIM master′s node_number.
# splstdata -b -l 3
List Node Boot/Install Information
Node#
hostname hdw_enet_addr srvr
response
install
last_install_image
last_install_time next_install_image
------------------------------------------------------------------------3 sp2n03
10005AFA082C
1
disk
hdisk0
bos.obj.ssp.41 Sat_May__4_12:57:38
bos.obj.ssp.41
2. Determine the NIM master hostname by issuing splstdata -b -l
<server_node_number> and looking at the reliable host name.
# splstdata -b -l 1
List Node Boot/Install Information
node#
hostname hdw_enet_addr srvr
response
instal
last_install_image
last_install_time next_install_image
------------------------------------------------------------------------1 sp2n01
10005AFA18CF
0
disk
bos.obj.ssp.41 Sat_May__4_10:42:40
bos.obj.ssp.41
3. Log in to the NIM master by using the telnet or rsh command:
# telnet sp2n01
4. Use lsnim to list the objects in the NIM master′ s database:
# lsnim
master
boot
nim_script
spnet
sp2cw0
lppsource
psspspot
noprompt
prompt
54
SP PD Guide
machines
resources
resources
networks
machines
resources
resources
resources
resources
master
boot
nim_script
ent
standalone
lpp_source
spot
bosinst_data
bosinst_data
This soft copy for use by IBM employees only.
psspscript
mksysb_1
cw_tr0
sp2n02
sp2n03
sp2n04
sp2n05
sp2n06
sp2n07
sp2n08
resources
resources
networks
machines
machines
machines
machines
machines
machines
machines
script
mksysb
tok
standalone
standalone
standalone
standalone
standalone
standalone
standalone
5. While still on NIM master, issue lsnim -l <client_name> to list the NIM
client definition for the node that is having the problem:
# lsnim -l sp2n03
sp2n03:
class
=
type
=
Cstate
=
Mstate
=
Cstate_result =
prev_state
=
platform
=
if1
=
cable_type1 =
cpuid
=
machines
standalone
ready for a NIM operation
currently running
success
not running
rs6k
spnet sp2n03 10005AFA082C ent
bnc
000116875700
6. From the first step (output of splstdata -b -l 3), node 3 (sp2n03) had a
response (bootp_response) of disk . The Cstate attribute for the client
Ready for nim operation from the output of lsnim -l sp2n03 is correct.
Based on the bootp_response for the node, the Cstate attribute is fixed and
will have fixed NIM object allocations for the client. The following table could
be used as a ready reckoner for NIM client definition information.
bootp_response
Cstate
Allocation
install
BOS installation has been
enabled
spot
psspspot
lpp_source
lppsource
bosinst_data
noprompt
script
psspscript
mksysb
mksysb_1
Diagnostic boot has been
enabled
spot
psspspot
bosinst_data
prompt
BOS installation has been
enabled
spot
psspspot
bosinst_data
prompt
diag
maintenance
disk or customize
Ready for a NIM
operation
Table 5. NIM Client Definition Information
2.9.1.1 Export Problems
Following is an example of a successful export by the exportfs command from
NIM master node sp2n01 of a NIM client sp2n08, which is ready to be installed.
Chapter 2. The Installation Process
55
This soft copy for use by IBM employees only.
#
exportfs sp2n03
/var/adm/acct
-root=SP2CW0:
\
sp2tr0:sp2cw0,access=SP2CW0:sp2tr0:sp2cw0=machines
/spdata/sys1/install/pssplpp
-ro
/export/nim/scripts/sp2n08.script
-ro,root=sp2n08,access=sp2n08
/usr
-ro,root=sp2n08,access=sp2n08
/spdata/sys1/install/pssp/bosinst_data
-ro,root=sp2n08,access=sp2n08
/spdata/sys1/install/pssp/pssp_script
-ro,root=sp2n08,access=sp2n08
/spdata/sys1/install/images/bos.obj.ssp.41 -ro,root=sp2n08,access=sp2n08
However, sometimes a node will appear in exportfs output from the NIM master
even if you never defined that particular node as a NIM client. For example, this
could happen if the NIM database is out of sync in a situation where NIM has not
successfully removed the NIM client with a previous NIM command.
To diagnose the problem with the definition of your nodes as NIM clients, use the
exportfs command to list the exported directories on the NIM master.
1. List the exports:
# exportfs
/spdata/sys1/install/pssplpp
-ro
/spdata/sys1/install/lppsource
-ro
/spdata/sys1/install/images/bos.obj.ssp.41 -ro,root=sp2n08
In this case, assume sp2n08 is the client that you are trying to define, but the
exportfs command does not list resources that should be allocated to the
NIM client. At the same time sp2n08 is listed in the
/spdata/sys1/install/images/bos.obj.ssp.41 entry.
2. To correct this situation, you must issue the rmnfsexp command to remove
the client from the exported list.
# rmnfsexp -d /spdata/sys1/install/images/bos.obj.ssp.41
unexported /spdata/sys1/install/images/bos.obj.ssp.41
3. List the exportfs again to verify that the exported directory has been
removed from the export list:
# exportfs
/spdata/sys1/install/pssplpp
/spdata/sys1/install/lppsource
-ro
-ro
Now that the NFS export has been corrected, you can issue setup_server on
the NIM master to redefine the NIM client.
2.9.2 Setup_server Fails
There are several reasons why setup_server can fail while creating and
allocating NIM resources. The most likely case is that the lppsource, psspspot,
or mksysb_1 resource cannot be created. It is quite unlikely that one of the
resources noprompt, prompt, or psspscript fails to create.
The noprompt resource needs access to the file
/spdata/sys1/install/pssp/bosinst_data. This file is copied by setup_server from
the file /usr/lpp/ssp/install/config/bosinst_data.template. Make sure this file
exists before setup_server is called. This file is part of the ssp.basic fileset.
The same applies to the resources prompt and psspscript. Make sure the files
/usr/lpp/ssp/install/config/bosinst_data_prompt.template and
/usr/lpp/ssp/install/bin/pssp_script exist.
56
SP PD Guide
This soft copy for use by IBM employees only.
2.9.2.1 lpp_source Creation Fails
#
setup_server
setup_server: Creating the lppsource resource
warning: 0042-176 c_mk_lpp_source: The resource located in
/spdata/sys1/install/lppsource
cannot serve as a ″support images″ (or ″simages″) lpp_source
because one or more of the following filesets are missing:
bos.net
setup_server: 0016-072 Error detected processing the following nim command:
/usr/sbin/nim -o define -t lpp_source -a server=master \
-a location=/spdata/sys1/ install/lppsource lppsource
Return code = 8. Check any previous error messages for possible problems.
There are several reasons why the SP lpp_source lppsource can fail to be
created. The most likely reason for this is that some filesets are missing in the
/spdata/sys1/install/lppsource directory. Compare all filesets in this directory
with the list given in Step 8 of the installation process in the RS/6000 SP
Installation Guide , GC23-3898.
This list is defined in the file /usr/lpp/bos.sysmgt/nim/methods/c_sh_lib by the
variable SIMAGES_OPTIONS
SIMAGES_OPTIONS=″\
bos \
bos.info.any \
bos.net \
bos.rte.up \
bos.rte.mp \
bos.diag \
bos.powermgt \
bos.sysmgt \
bos.terminfo.all \
devices.all \
X11.apps \
X11.base \
X11.compat \
X11.Dt \
X11.fnt \
X11.loc \
X11.motif \
X11.msg.all \
X11.vsm″
In this case, the fileset bos.net is missing. To recover from the problem, copy
the missing fileset into /spdata/sys1/install/lppsource and run setup_server
again.
2.9.2.2 spot Creation Fails
If setup_server fails to create the psspspot resource, verify that the following
resources are available:
1. First verify that none of the filesystems are full.
2. Verify that the root filesystem (/) has enough space. The NIM network install
images will reside in /tftpboot. NIM recommends that you have enough
Chapter 2. The Installation Process
57
This soft copy for use by IBM employees only.
room for eight 2.5 MB images or a total of 20 MB. However, once the
images have been created, you only need psspspot.rs6k.ent. The other
images could be deleted. Accordingly, one may say that you only need one
file of 2.5 MB.
3. There should be at least 1 M B of free space in /tmp.
4. List the lppsource resource to see if it is available.
# lsnim -l lppsource
lppsource:
class
type
server
location
alloc_count
Rstate
prev_state
simages
=
=
=
=
=
=
=
=
resources
lpp_source
master
/spdata/sys1/install/lppsource
0
ready for use
unavailable for use
yes
The Rstate is ready for use and the simages is yes.
If the simages attribute is no, then the required images for the support images
needed to create the SPOT were not available in the lppsource resource.
The required images needed for the SPOT creation are listed in the
REQUIRED_SIMAGES variable in the file
/usr/lpp/bos.sysmgt/nim/methods/c_sh_lib.
REQUIRED_SIMAGES=″\
bos \
bos.net \
bos.rte.up \
bos.rte.mp \
bos.diag \
bos.sysmgt \
bos.terminfo \
bos.terminfo.all.data \
devices.base.all \
devices.buc.all \
devices.graphics.all \
devices.mca.all \
devices.scsi.all \
devices.sio.all \
devices.sys.all \
devices.tty.all″
Before you run setup_server, again it may be necessary to remove the
incomplete created psspspot.
# nim -o remove psspspot
2.9.2.3 mksysb Creation Fails
58
SP PD Guide
This soft copy for use by IBM employees only.
#
setup_server
0042-001 nim: processing error encountered on ″master″ :
0042-001 m_mkbosi: processing error encountered on ″master″ :
0042-154 c_stat: the file ″ / spdata/sys1/install/images/bos.obj.ssp.41″
does not exist
setup_server: 0016-072 Error detected processing the following nim command:
/usr/sbin/nim -o define -t mksysb -a server=master -a location=/spdata/sys1/inst
all/images/bos.obj.ssp.41 mksysb_1
Return code = 1. Check any previous error messages for possible problems.
If setup_server cannot create the mksysb_1 resource, verify that:
1. /spdata/sys1/install/images exists with permissions rwxr-sr-x.
2. The mksysb image exists with the correct name, either the default mksysb
name or the one you have specified before running setup_server. Make sure
the permissions are at least rw-r--r--.
If you have more than one mksysb image, the names of the mksysb resources
are mksysb_2, mksysb_3, and so on.
2.9.2.4 psspspot Allocation Fails
#
setup_server
setup_server: Checking NIM client - sphps01
setup_server: Checking NIM client allocations - sphps01.aixedu
setup_server: Allocating resources for client sphps01
0042-001 nim: processing error encountered on ″master″ :
0042-001 m_allocate: processing error encountered on ″master″ :
0042-058 m_alloc_spot: unable to allocate ″psspspot″ to ″sphps01″
because it does not support the network interface type
of that client
setup_server: 0016-072 Error detected processing the following nim command:
/usr/sbin/nim -o allocate -a spot=psspspot -a lpp_source=lppsource -a bosinst_da
ta=noprompt -a script=psspscript -a mksysb=mksysb_2 sphps01
Return code = 1. Check any previous error messages for possible problems.
If allocating the psspspot resource fails, follow these steps to determine and
correct the problem:
1. Perform a check on the SPOT
# nim -o check psspspot
This check should inform you if there is a problem. In our environment the
command produced the following message:
0042-001 nim: processing error encountered on ″master″ :
0042-062 m_ckspot: ″psspspot″ is missing something which is
required
2. If you are unable to determine the problem with the SPOT, you can update
the SPOT by issuing the following command:
# nim -o cust -a lpp_source=lppsource psspspot
In our environment this did not work either because of the severity of the
problem with the SPOT. Instead we got the following message:
Chapter 2. The Installation Process
59
This soft copy for use by IBM employees only.
0042-001 nim: processing error encountered on ″master″ :
0042-001 m_instspot: processing error encountered on ″master″ :
0042-062 m_ckspot: ″psspspot″ is missing something which is
required
3. If the problem persists, you can remove the SPOT.
# nim -Fo remove psspspot
Then run setup_server to recreate the SPOT. Alternatively, you can run the
following nim command:
# nim -o define -t spot -a server=master -a source=lppsource \
-a location=/usr psspspot
2.9.3 Debugging NIM Installations
Sometimes, the only way to discover a problem is by debugging NIM. This
procedure will help to precisely identify which step in the installation process is
failing. However, the actions needed to correct the problem will vary depending
on the failing step. The debug option is a low lever tool provided by creating a
spot in debug mode, which will let you run the installation process in a
step-by-step basis. Perform the following steps to debug the installation of your
nodes.
1. spbootins -r disk <Frame#> <Node#> <NumberOfNodes>
This command resets the specified nodes to disk and calls all necessary NIM
commands to reset the install configuration. Always use this command to
start your new configuration from a well-defined point.
2. nim -Fo check -a debug=yes psspspot
This command creates the SPOT in debug mode.
3. lsnim -l psspspot
Display the attributes of the SPOT resource and look for a line containing the
string enter_debug = rs6k. There will be an address imbedded in the text like
0x0013d410. Remove the starting 0x and write the remaining number down.
It will be used in a later step.
# lsnim -l psspspot
psspspot:
class
type
version
server
location
alloc_count
Rstate
prev_state
release
if_supported
if_supported
if_supported
if_supported
if_supported
if_supported
if_supported
enter_dbg
enter_dbg
enter_dbg
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
resources
spot
04
master
/usr
0
ready for use
ready for use
01
rs6k ent
rs6k fddi
rs6k tok
rs6ksmp ent
rs6ksmp tok
rspc ent
rspc tok
″rs6k 0x0013d410″
″rs6ksmp 0x0015d2b0″
″rspc 0x0013d410″
4. spbootins -r install <Frame#> <Node#> <NumberOfNodes>
60
SP PD Guide
This soft copy for use by IBM employees only.
All the specified nodes are set to install and the NIM commands for resource
allocation are called.
5. nim -Fo check psspspot
This last command resets the SPOT back to a no debug version. Do not
forget to do this step unless you have also installation problems on other
nodes.
2.10 Network Booting
There are three different booting modes supported by PSSP V2.1 which require a
network boot to be performed.
1. Installing nodes
Typically no external devices like tape drives or CDROM drives are
connected to the nodes of a RS/6000 SP. Therefore, it is necessary to install
the nodes over the network, including the boot phase. This also applies to
the two following tasks.
2. Maintaining nodes
Normally, the maintenance mode is used when there is a problem booting
the node, and it is necessary to get access to the rootvg volume group to
figure out and fix the problem. More details about this mode will be given
later.
3. Diagnosing nodes
Using this mode allows you to run some diagnostics on any device, including
disks and SCSI adapters, since the node is booted from the network. This
mode will be covered later in this chapter in more detail.
The command spbootins prepares the installation server to be able to serve NIM
installations, including serving as network boot server. A variety of other task
are also performed by spbootins. For instance, the bootp_response field for the
node in the SDR is changed, and the script setup_server is called. The
configuration of the installation server itself is done by setup_server.
The following example prepares the boot/install server to install the node with
node numbers 1 and 3.
# spbootins -r install -l 1,3
The spbootins scripts supports the following boot response modes:
1. install
With this mode, setup_server will allocate the following NIM resources:
psspspot , lppsource , noprompt , psspscript and mksysb_1 . Furthermore the
files /tftpboot/<hostname>.info, /tftpboot/<hostname>-new-srvtab,
/tftpboot/<hostname>.install_info and /tftpboot/<hostname>.config_info
are created and /etc/bootptab is updated to enable this machine to act as
boot server. The bootp_response install requires a network boot.
2. maintenance
In case you select the maintenance bootp_response, other resources are
allocated to the NIM client representing the node which will be run in
maintenance mode: psspspot, lppsource, prompt, boot, and nim_script.
Chapter 2. The Installation Process
61
This soft copy for use by IBM employees only.
Similar to the install mode the files /tftpboot/<hostname>.info,
/tftpboot/<hostname>.install_info, and /tftpboot/<hostname>.config_info
are created and /etc/bootptab is updated to enable this machine to act as
boot server. The bootp_response maintenance requires a network boot.
3. diag
The selection of the diag bootp_response allocates the following resources to
the NIM machine object: psspspot, prompt, and boot. The same file as in
the two other boot response modes are being created. The bootp_response
diag requires a network boot.
4. customize
The bootp_response customize deallocates all resources of a given NIM
client, removes the NIM client, and recreates it. No resources are allocated.
The files /tftpboot/<hostname>.install_info and
/tftpboot/<hostname>.config_info are created beside
/ t f t p b o o t / < h o s t n a m e > - n e w - s r v t a b . No network boot is required.
5. disk
This bootp_response mode finally changes the bootp_response field in the
SDR to disk and removes the resource allocations of a NIM client. The file
/tftpboot/<hostname>.info is removed, as well as the entry in the
/etc/bootptab file for that client. No network boot is required.
2.10.1 Scripts Involved in Network Boot
The main script involved in the network boot process is /sbin/rc.boot. This script
is called first in boot phase one (/sbin/rc.boot 1). Basically the following steps
are performed at that time:
1. Read the IPL control block ( bootinfo -b) to get information such as client
address, the boot server address, gateway information, the network adapter
to use, the bootfile name, and others.
2. Configure the given network device by use of the received IP parameters. If
this fails, you see LED code 607, a failure that is quite unlikely.
3. Now the / t f p t b o o t / < h o s t n a m e > . i n f o file is tftp′ d from the installation server
to the local file /SPOT/niminfo. When this tftp transfer fails, the client node
stops with a LED code of 608. This file contains a set of environment
variables which define the current installation environment. This file is
sourced (/SPOT/niminfo) and the environment variables are set in the
current shell. If this fails, you see the LED error code 609.
4. A more likely step to fail is the mount which is performed now. The SPOT is
mounted in the RS/6000 SP environment by the command mount
bootserver:/usr /SPOT/usr. This step sometimes fails due to incorrect NFS
configuration on the installation server. The typical LED error code is 611.
Sometimes, there is a routing problem between the client node and the
Control Workstation. Even when the client node is installing from a
boot/install server other than the Control Workstation, a route is required
from the Control Workstation to the client node. If this is the case, 610 is the
LED code where the node will stop. If you see the 612, the mount was
successful. We discuss this situation later in this chapter.
5. Depending on the reason for the network boot, the next step may vary. If
you perform an installation, the script /usr/lib/boot/network/rc.bos_inst is
copied from the SPOT into the local /etc: directory and also sourced. If you
62
SP PD Guide
This soft copy for use by IBM employees only.
perform a network boot for diagnostic reasons, the file
/usr/lib/boot/network/rc.diag is copied and sourced. The last possible script
is /usr/lib/boot/network/rc.dd_boot, but it is not used in the RS/6000 SP
environment. It would perform a normal network boot (for instance, in a
diskless/dataless environment).
The /etc/rc.bos_inst script also distinguishes boot phases.
In the first phase, some filesystems and files are mounted from the installation
server. This list of directories is defined in the NIM_MOUNTS environment
variable, set by the script /SPOT/niminfo.
This list includes the directory /spdata/sys1/install/lppsource, which is mounted
over /SPOT/usr/sys/inst.images; the file /spdata/sys1/install/pssp/bosinst_data,
which is mounted over /NIM_BOSINST_DATA, and the mksysb file
/spdata/sys1/install/images/bos.obj.ssp.41, which is mounted on
/NIM_BOS_IMAGE.
In case one of these mounts cannot be performed, you will see the LED error
code 611.
The /usr/lpp/bosinst/bi_main script is called from /etc/rc.bos_inst during the
second phase of /sbin/rc.boot. This script triggers the installation process.
If you have problems within the beginning of the installation, look at some of
these scripts to figure out which condition may cause the installation to fail.
Let′s have a closer look at the /tftpboot/<hostname>.info file to gain a better
understanding of some parameters of the installation process. This will help us
to find and fix network boot and installation-related problems.
2.10.1.1 The /tftpboot/<hostname>.info File
export
NIM_NAME=sphps03
export NIM_MASTER_HOSTNAME=spcntl.aixedu
export RC_CONFIG=rc.bos_inst
export SPOT=spcntl.aixedu:/usr
export NIM_BOSINST_DATA=/NIM_BOSINST_DATA
export NIM_BOS_IMAGE=/NIM_BOS_IMAGE
export NIM_BOS_FORMAT=mksysb
export NIM_MOUNTS=″ spcntl.aixedu:/spdata/sys1/install/lppsource: \
/SPOT/usr/sys/inst.images:dir \
spcntl.aixedu:/spdata/sys1/install/pssp/bosinst_data:/NIM_BOSINST_DATA:file \
spcntl.aixedu:/spdata/sys1/install/images/bos.obj.ssp.41:/NIM_BOS_IMAGE:file ″
This is only an excerpt of some important variables of the
/tftpboot/<hostname>.info file created for a installation of a mksysb image.
NIM_NAME
This variable defines the name of the NIM client object owning
this file.
Chapter 2. The Installation Process
63
This soft copy for use by IBM employees only.
NIM_MASTER_HOSTNAME
This variable defines the name of the NIM master from which
this NIM client is installed.
RC_CONFIG
This variable contains the name of the script used to continue
the installation. This script will be called from the /etc/rc.boot
script. Possible names other than rc.bos_inst are rc.diag and
rc.dd_boot.
SPOT
This variable defines the location of the SPOT on the
boot/installation server. In the PSSP 2.1 environment, this is
always /usr.
NIM_BOSINST_DATA
The name of the bosinst_data file for this installation is stored in
this environment variable.
NIM_BOS_IMAGE
Here we find the name of the image to be installed on the node.
NIM_BOS_FORMAT
One format of an installation image is mksysb. Another is, for
instance, rte , which leads to a basic BOS installation. In the
RS/6000 SP environment, this variable is always set to mksysb
for the installation process. In case of a diagnostic network
boot, it contains the value rte. Compare this with the three
examples given following this list.
NIM_MOUNTS
This variable defines the list of directories and files being
mounted from the installation server while performing the
requested network boot process.
64
SP PD Guide
This soft copy for use by IBM employees only.
Following is an example of a host.info file created for a NIM installation:
#------------------
Network Install Manager --------------# warning - this file contains NIM configuration information
# and should only be updated by NIM
export NIM_NAME=sphps03
export NIM_HOSTNAME=speth03.aixedu
export NIM_CONFIGURATION=standalone
export NIM_MASTER_HOSTNAME=spcntl.aixedu
export NIM_MASTER_PORT=1058
export RC_CONFIG=rc.bos_inst
export NIM_BOSINST_ENV=″ / . . / SPOT/usr/lpp/bos.sysmgt/nim/methods/c_bosinst_env″
export NIM_BOSINST_RECOVER=″ / . . / SPOT/usr/lpp/bos.sysmgt/nim/methods/ \
c_bosinst_env -a hostname=speth03.aixedu″
export SPOT=spcntl.aixedu:/usr
export NIM_BOSINST_DATA=/NIM_BOSINST_DATA
export NIM_CUSTOM=″ / . . / SPOT/usr/lpp/bos.sysmgt/nim/methods/ \
c_script -a location=spcntl.aixedu:/export/nim/scripts/sphps03.script″
export NIM_BOS_IMAGE=/NIM_BOS_IMAGE
export NIM_BOS_FORMAT=mksysb
export NIM_HOSTS=″ 192.168.0.3:speth03.aixedu 192.168.0.200:spcntl.aixedu ″
export NIM_MOUNTS=″ spcntl.aixedu:/spdata/sys1/install/lppsource: \
/SPOT/usr/sys/inst.images:dir \
spcntl.aixedu:/spdata/sys1/install/pssp/bosinst_data:/NIM_B OSINST_DATA:file \
spcntl.aixedu:/spdata/sys1/install/images/bos.obj.ssp.41:/N IM_BOS_IMAGE:file ″
Following is an example of a host.info file created for a maintenance network
boot:
#------------------
Network Install Manager --------------# warning - this file contains NIM configuration information
# and should only be updated by NIM
export NIM_NAME=sphps03
export NIM_HOSTNAME=speth03.aixedu
export NIM_CONFIGURATION=standalone
export NIM_MASTER_HOSTNAME=spcntl.aixedu
export NIM_MASTER_PORT=1058
export RC_CONFIG=rc.bos_inst
export NIM_BOSINST_ENV=″ / . . / SPOT/usr/lpp/bos.sysmgt/nim/methods/c_bosinst_env″
export NIM_BOSINST_RECOVER=″ / . . / SPOT/usr/lpp/bos.sysmgt/nim/methods/ \
c_bosinst_env -a hostname=speth03.aixedu″
export SPOT=spcntl.aixedu:/usr
export NIM_BOSINST_DATA=/NIM_BOSINST_DATA
export NIM_CUSTOM=″ / . . / SPOT/usr/lpp/bos.sysmgt/nim/methods/ \
c_script -a location=spcntl.aixedu:/export/nim/scripts/sphps03.script″
export NIM_BOS_IMAGE=/SPOT/usr/sys/inst.images/bos
export NIM_BOS_FORMAT=rte
export NIM_HOSTS=″ 192.168.0.3:speth03.aixedu 192.168.0.200:spcntl.aixedu″
export NIM_MOUNTS=″ spcntl.aixedu:/spdata/sys1/install/lppsource: \
/SPOT/usr/sys/inst.images:dir \
spcntl.aixedu:/spdata/sys1/install/pssp/bosinst_data_prompt: \
/NIM_BOSINST_DATA:file″
Following is an example of a host.info file created for a diagnosis network boot:
Chapter 2. The Installation Process
65
This soft copy for use by IBM employees only.
#------------------
Network Install Manager --------------# warning - this file contains NIM configuration information
# and should only be updated by NIM
export NIM_NAME=sphps03
export NIM_HOSTNAME=speth03.aixedu
export NIM_CONFIGURATION=standalone
export NIM_MASTER_HOSTNAME=spcntl.aixedu
export NIM_MASTER_PORT=1058
export RC_CONFIG=rc.diag
export SPOT=spcntl.aixedu:/usr
export NIM_BOSINST_DATA=/NIM_BOSINST_DATA
export NIM_BOS_IMAGE=/SPOT/usr/sys/inst.images/bos
export NIM_BOS_FORMAT=rte
export NIM_HOSTS=″ 192.168.0.3:speth03.aixedu 192.168.0.200:spcntl.aixedu ″
export NIM_MOUNTS=″ spcntl.aixedu:/spdata/sys1/install/pssp/ \
bosinst_data_prompt:/NIM_BOSINST_DATA:file ″
2.10.2 Node Installation Diagnostics
If a node fails to install a mksysb image from its boot/install server in network
boot mode, then try the node conditioning method. Node conditioning may
provide you with information as to where the node install is failing.
The following steps can be used to determine the cause of the node install
failure and how to resolve them.
Step 1: Verify Boot/Install Server is Available
Do the following steps to verify that the boot/install server is available:
1. Determine the client′ s boot/install server by issuing: splstdata -b -l
<client_node_number> and looking at the srvr field, which lists the
boot/install server′s node_number.
# splstdata -b -l 3
List Node Boot/Install Information
Node#
hostname hdw_enet_addr srvr
response
install
last_install_image
last_install_time next_install_image
------------------------------------------------------------------------3 sp2n03
10005AFA082C
1
disk
hdisk0
bos.obj.ssp.41 Sat_May__4_12:57:38
bos.obj.ssp.41
2. Determine the boot/install server′ s host name by issuing splstdata -b
-l <server_node_number> and looking at the hostname.
# splstdata -b -l 1
List Node Boot/Install Information
node#
hostname hdw_enet_addr srvr
response
instal
last_install_image
last_install_time next_install_image
------------------------------------------------------------------------1 sp2n01
10005AFA18CF
0
disk
bos.obj.ssp.41 Sat_May__4_10:42:40
bos.obj.ssp.41
3. Login to the boot/install server by using telnet or the rsh command.
# telnet sp2n01
4. Check /etc/bootptab for the node that you are installing. If the node is
not listed in this file, then review the NIM client definition as follows:
•
66
SP PD Guide
Determine the client′s NIM master.
This soft copy for use by IBM employees only.
•
Determine the NIM master host name.
•
Login to NIM master.
•
List the objects in the NIM database.
•
While still on the NIM master, list the NIM client definition for the
node having a problem.
•
Compare the values of the bootp_response and Cstate attributes for
the client node.
•
If the comparison is ok, then the NIM configuration is correct, and
all that needs to be done is to reconfigure boot/install/usr server
information for the node in question. If the comparison does not
match, then you will have to reconfigure NIM.
5. If the node is listed in this file, continue to Step 2 below:
Step 2: Check Console Messages
1. At the Control Workstation, open a write tty to the node with the install
problem by issuing:
#s1term -w <frame_number> <node_number>
2. Wait several minutes to see if any error messages are displayed on the
tty that you opened. An error message might tell you what the problem
is. Also look for NIM messages on the tty that might suggest that the
installation is proceeding. An example of a NIM progress message is:
/ step_number, of total_steps complete
Step 3: Check Image Availability
Check to see if the image is available and the permissions are appropriate.
Issue:
# /usr/lpp/ssp/bin/splstdata -b
The next_install_image field lists the name of the image to be installed. If
the field for this node is set to default, the default image (specified by the
install_image attribute of the SP object) will be installed. The images are
found in the /spdata/sys1/install/images directory.
Step 4: Check NIM Configuration for the Node
How to check NIM configuration for a node has already been explained.
Example of resolving Node Install Problem
Here is an example of a problem when installation of node 8, sp2n08 ,
failed. Previously the installation process was interrupted for this node.
Later Net Boot stopped on LED 231, which means attempting a normal
mode IPL from Ethernet specified in IPL ROM . After several retries, the
LED code 239 appears, meaning that the boot/install server is not
responding. Then an install was tried through node conditioning . Ping
between boot/install server sp2n01 and client sp2n08 succeeded, but the
install process got stuck on LED 260, which means displaying information
on the display console.
1. splstdata -b -l 8 pointed to node 1 as the boot/install server for client
node 8.
2. splstdata -b -l 1 provided boot/install server′ s host name sp2n01 for
boot/install node 1.
Chapter 2. The Installation Process
67
This soft copy for use by IBM employees only.
3. telnet sp2n01 was enabled to login to the boot/install server node.
4. /etc/bootptab was checked and found that it does not have an entry for
sp2n08 .
So you now need to check NIM info.
5. Login to sp2n01 and a check of lsnim showed that sp2n08 is available.
lsnim -l sp2n08 listed the following entry for Cstate .
Cstate
= ready for a NIM operation
As the boot response for node 8 was disk , Cstate value is correct.
6. The following smit command was executed on the Control Workstation:
# smitty server_dialog
Also, you may use the PSSP command spbootins, as follows:
# spbootins -n 1 -r install -h hdisk0 -s yes -l 8
The -s yes tells spbootins to run setup_server after changing the SDR
values for this node.
Figure 23 shows the output from setup_server.
setup_server
command results from sp2n01
setup_server: Starting setup_server
setup_server: Running services_config script to configure SSP services.
This may take a few minutes...
setup_server: Getting Node object information from the SDR
setup_server: Creating Node arrays for processing
setup_server: Getting SP Object information from the SDR
setup_server: Checking to see if this system is an install server
setup_server: Performing node install server setup
setup_server:get_image:no transfer required
setup_server: Checking to see if bos.sysmgt.nim.master is installed
setup_server: bos.sysmgt.nim.master is installed.
setup_server: Checking to see if bos.sysmgt.nim.spot is installed
setup_server: bos.sysmgt.nim.spot is installed.
setup_server: NIM master is configured
setup_server:
nst.data, and
setup_server:
setup_server:
setup_server:
setup_server:
Checking the NIM master resources - lpp_source, spot, mksys
script
spot exists
bosinst_data noprompt resource exists
bosinst_data prompt resource exists
script resource exists
setup_server:
setup_server:
setup_server:
setup_server:
setup_server:
setup_server:
Checking NIM client - sp2n08
Checking NIM client allocations - sp2n08
Allocating resources for client sp2n08
Creating the /tftpboot/sp2n08.install_info file
Creating the /tftpboot/sp2n08.config_info file
Copying /tftpboot/sp2n08-new-srvtab from sp2cw0
Figure 23. Output from setup_server
68
SP PD Guide
This soft copy for use by IBM employees only.
The /etc/bootptab was checked, and now it had an entry for sp2n08 as
follows:
sp2n08:bf=/tftpboot/sp2n08:ip=9.12.20.8:
ht=ethernet:ha=10005AFA1B12:sa=9.12.20.1:
sm=255.255.255.0:
7. Net Boot was tried again and now it worked.
2.11 Node Customization Problems
When a node is installed, its bootp_response option in the SDR is set to install .
With this option, the node is network-booted and the installation process begins
with the AIX BOS installation. After the first part of the installation is finished,
the customization process takes place. This customization process consists of
running the pssp_script on the node just installed. This script is the heart of the
customization process.
The output of this script is sent to /var/adm/SPlogs/sysman/<node>.config.PID.
The variables used by this script are set in <node reliable
hostname>.install_info file in /tftpboot on the boot install server at the node
being customized or installed. Also, some variables are taken from /sbin/rc.boot
file on the node.
The pssp_script installs any additional lpp and device drivers needed on the
node, and finally, executes the /tftpboot/script.cust and /tftpboot/tuning.cust
scripts after transferring them from the boot install server.
The same script sets back to disk the bootp_response option in the SDR and
resets the NIM machine object for that node.
2.11.1 Why a Node Is Not Being Customized
The reasons why a node is not customized are many. However, the reasons will
vary, depending on whether the node was being installed, or customized.
•
If This is an Installation
Since during the post-install process some lpps are installed along with
device drivers needed in the node, the post-install process can fail due to
some lpps or device drivers being missing in the lppsource directory. Some
times those lpps are deleted to save space, and the problem arises
whenever you recreate the SPOT or are trying to install a new node.
The SPOT must be created with the original lpp sources. For example, if a
system was originally installed at AIX 4.1.2 level, and then was later updated
to AIX 4.1.4, the AIX 4.1.2 install images must be used as the source to
create the /usr SPOT. The resultant /usr SPOT will be at the proper AIX 4.1.4
level when the SPOT creation is complete.
Alternatively, it is also possible to first create the /usr SPOT at the original
level, and then apply all updates to bring the /usr SPOT to the latest level.
Another problem that can be present during installation or even just
customization is the use of short names instead of long names. After
applying PTF 12, pssp_script had a problem handling short names. Nodes
were stopping with LED u73.
•
If This is a Customization
Chapter 2. The Installation Process
69
This soft copy for use by IBM employees only.
The problem is that the perl script mkinstall, called it from setup_server,
creates the install_info file using the initial_hostname. However, pssp_script
on the other end expects the reliable_hostname.
The mkinstall and mkconfig were changed to use the reliable_hostname
instead. Every PSSP component is sensitive to the initial_hostname or
reliable hostname variables on the SDR, so keeping them clear will avoid a
lot of problems.
Installing the NIM master option in a node that never was a boot/install
server was a problem until PTF set 9. The problem was that the installation
of this lpp created a /etc/niminfo.prev file that prevented the nodes from
being customized.
Anytime you have a problem customizing a node, be sure that pssp_script runs
as expected, taking a look at the console log file on the node at
/var/adm/SPlogs/sysman/<node>.console.log.
70
SP PD Guide
This soft copy for use by IBM employees only.
Chapter 3. Kerberos
This chapter briefly describes the role of Kerberos on the RS/6000 SP.
3.1 Overview
The RS/6000 SP currently uses authentication services based on MIT Kerberos
version 4. Kerberos functions as a third party to authenticate the identities of
clients and servers. Kerberos on the RS/6000 SP is used to initially authenticate
the identity of the user and to provide information through which the server can
authenticate the identity of clients in a distributed environment. The underlying
mechanism for authenticating users and services is a ticket scheme.
For a more detailed explanation of how Kerberos works, see Chapter 14,
“Understanding Secure Authentication,” in RS/6000 Scalable POWERparallel
Systems: PSSP Version 2 Technical Presentation , SG24-4542.
3.1.1 Authentication
Authentication refers to the process of checking the correct identity of
transmissions; that is, the ability to validate the identity of a user or server.
3.1.2 Authorization
Authorization refers to the process of defining the functions that a user or
process is permitted to perform.
Kerberos provides authentication services that allow certain distributed services
within the SP system, and between it and other workstations (clients), to
securely control access to their services. The root user must use Kerberos
(taking on the role of the Kerberos administrator) when installing the SP system,
because the installation process includes the creation and modification of the
Kerberos security database.
3.1.3 Distributed Commands
Kerberos is also required to use the authenticated distributed commands such
as dsh, the p* commands and sysctl.
3.1.4 Remote Commands
Kerberos provides authenticated (Kerberized) versions of rsh and rcp in the
/usr/lpp/ssp/rcmds/bin directory. Customers wishing to use the .rhosts
mechanism to restrict access to clients can still do so by using the standard AIX
versions of these commands in the /usr/bin directory.
3.1.5 .rhosts
Using Kerberos avoids the need for the root user to have a .rhosts file to control
access to network services such as rsh and rcp.
Kerberos is a method of authentication that is not related to any AIX
authentication system, nor is it used as an additional login verification.
Therefore, if someone (other than the system administrator) can log into the
Control Workstation as root, they can destroy the Kerberos database.
 Copyright IBM Corp. 1996
71
This soft copy for use by IBM employees only.
3.2 Terminology
Kerberos clients (user) and services are uniquely identified by a principal
identifier, which consists of three components:
•
A principal name
•
An instance name
•
A realm name
3.2.1 Principal
Kerberos defines a name space of authenticated users and services. Each
different client and service has a unique principal name. An RS/6000 SP user
who wishes to use any Kerberos-authenticated service must be registered to
Kerberos (by using kadmin or kdb_edit commands). By virtue of this registration,
the user then becomes a Kerberos user (also known as a principal). A private
DES key is created for the user and stored in the Kerberos database.
Note that the Kerberos name space is unrelated to the AIX name space, so that
an individual may be known by one name to Kerberos and by another name to
AIX. However, it is more convenient to assign the same name in each space.
It is possible to have multiple AIX users all using the same Kerberos user to
gain access to authenticated services. For example, you can do the following:
1. Define two non-root AIX users, Fred and Joe, on the Control Workstation
(make sure that the users are exist on the nodes, as well).
2. Use the command /usr/kerberos/bin/kadmin to add a Kerberos user called
kerb.
3. Create a new file, .klogin, in the home directory of the two new AIX users.
This file should contain a line similar to kerb@SP21CW0.
4. Log on as either user Fred or Joe and execute kinit kerb. The user can
now run any of the Kerberos-authenticated commands.
A principal can also refer to a Kerberos-protected service. In this way server
programs can be authenticated. For example, the hardmon service principal is
used by the hardmon and splogd server daemons.
3.2.2 Instance
The instance name is a label that allows the same client or service to exist in
several different forms that each require distinct authentication. In the case of
services, an instance may specify the host that provides the service. For client
principals, the instance can be useful when one wishes to have different
identifiers for different privileges. The usual case is that users operate using a
name with a null instance.
For example, the client or user principal “root.admin” represents an instance
(admin) used for administrative tasks. The service principal “hardmon.sp21cw0”
represents an instance (sp21cw0) indicating the node providing the service.
72
SP PD Guide
This soft copy for use by IBM employees only.
3.2.3 Realm
A realm is the set of principals sharing the same authentication database and
authentication server. The realm name identifies each independently
administered Kerberos site. Kerberos does not specify any constraints on the
form of the realm name. When setup_authent is run, the realm name is set to
the primary authentication server′s (usually the Control Workstation) domain
name converted to uppercase. If you want to set your own realm name, you
must edit the /etc/krb.conf and /etc/krb.realm files.
3.2.4 Ticket
To use a Kerberos service, a client must supply a ticket previously obtained from
Kerberos. A ticket for a service is a string of bits which have been encrypted
using the private key for that service. The ticket contains the following data:
•
•
•
•
•
The name of the client (user)
The current time
The length of time the ticket will be valid
The name of the workstation
A randomly created DES key (the session key)
3.2.5 Key
The key is the password associated with a Kerberos user or service. Keys are
stored in the Kerberos database. Keys are used to encrypt the data packets
used by Kerberos clients and services.
3.2.6 Ticket-Granting Ticket
When a user executes the kinit command, a request is sent to the
authentication server. This request contains the user′s (principal) name and the
name of a special Kerberos service, the ticket-granting service. The
authentication server checks if the user is known to Kerberos. If it is, Kerberos
creates a random session key and a ticket for the ticket-granting service. This
ticket contains:
•
•
•
•
•
•
The
The
The
The
The
The
client name
name of the ticket-granting server
current time
lifetime of the ticket
client′s IP address
session key (which was just created)
This ticket is encrypted with a key (using the principal′s password) known only to
the ticket-granting server and the authentication server and sent back to the
client. This ticket is then stored in the user′s ticket cache file (/tmp/tkt<uid>)
and is known as the ticket-granting ticket. Whenever the client goes back to
Kerberos for an additional service-specific ticket, the response is encrypted
using the session key from the ticket-granting ticket.
Chapter 3. K e r b e r o s
73
This soft copy for use by IBM employees only.
3.3 Components
The following options of the ssp installp image are relevant to Kerberos. The
component version numbers included are for PTF 11.
3.3.1 ssp.authent 2.1.0.2
This component contains the authentication server code and the authentication
administrator commands. It is installed on the primary authentication server
(typically the Control Workstation). This component is not installed on the nodes.
3.3.2 ssp.clients 2.1.0.5
This component is installed on the Control Workstation, the RS/6000 SP nodes,
and other RS/6000 hosts where Kerberos is used. It includes:
•
•
•
•
All user authentication commands
kshell services
spmon command line interface
Logging daemon
3.4 Install Process
The integration of Kerberos into PSSP scripts is almost transparent to the
installation process. The advantage to this is that the RS/6000 SP installations
can be completed with a minimal knowledge of Kerberos.
3.4.1 setup_authent
This script creates the primary authentication server. Within an authentication
realm, there must be at least one authentication server, but you may choose to
have more than one. When you configure your realm, you designate one
authentication server as the primary server (usually the primary server is the
Control Workstation). You may also setup secondary servers. Only the primary
server has the kadmind daemon that manages the authentication database.
setup_authent does the following:
1. Creates or updates /etc/krb.conf
2. Creates or updates /etc/krb.realms
3. Makes directory /var/adm/SPlogs/kerberos
4. Creates the authentication database using /usr/kerberos/etc/kb_init
5. Creates the master key cache file (/.k) using /usr/kerberos/etc/kstash
6. Adds the kerberos daemon to /etc/inittab and starts it.
7. Adds the kadmind daemon to /etc/inittab and starts it.
8. Defines the initial authentication administrator principal using kdb_ edit
9. Sets up the Kerberos ACLs in /var/kerberos/database/admin_acl.*
10. Runs kinit as root.admin and adds the local service principals
(hardmon.<CWname> and rcmd<CWname>).
11. Creates /.klogin to authorize the administrator principal to use remote
commands.
12. Creates the server key file /etc/krb_srvtab
74
SP PD Guide
This soft copy for use by IBM employees only.
For further details, see Appendix A, “RS/6000 SP Script Files” on page 229.
3.4.2 install_cw
This creates the hardware monitor ACLs in /spdata/sys1/spmon/hmacls. For
further details, see Appendix A, “RS/6000 SP Script Files” on page 229.
3.4.3 setup_server
This creates the Kerberos files intended for the nodes in the /tftpboot directory.
For further details, see Appendix A, “RS/6000 SP Script Files” on page 229.
3.4.4 Network Boot
This installs Kerberos on the nodes.
3.5 Daemons and Databases
The following daemons are described in this section:
Kerberos
kadmind
kpropd
The databases used by Kerberos are also described here.
3.5.1 Kerberos Daemon
The kerberos daemon only runs on the primary authentication server (usually
the Control Workstation). It is started by the setup_authent script and thereafter
invoked from /etc/inittab. This daemon is responsible for providing
ticket-granting tickets to clients so that they can access specific server
principals.
The kerberos daemon listens for requests on the kerberos4/udp port. If this port
is not defined in the /etc/services file, it uses port 750.
Notes:
1. In MIT Kerberos version 5, the kerberos daemon listens for requests on the
kerberos5/udp port (port 88).
2. There may be more than one kerberos daemon running on the server. This
allows for faster service if there are numerous client requests.
3.5.2 kadmind Daemon
The kadmind daemon only runs on the primary authentication server (usually the
Control Workstation). It is started by the setup_authent script and thereafter
invoked from /etc/inittab. This daemon is responsible for serving the Kerberos
administrative tools, such as changing passwords and adding principals. The
kadmind daemon also manages the primary authentication database.
The kadmind daemon listens for requests on the kerberos_master /tcp port. If
this port is not defined in the /etc/services file, it uses port 751.
Note: Only one kadmind daemon may run on the server.
Chapter 3. K e r b e r o s
75
This soft copy for use by IBM employees only.
3.5.3 kpropd Daemon
The kpropd daemon only runs on secondary authentication servers (if one or
more have been set up). The authentication databases used by the secondary
authentication servers are copies of the primary database. The databases are
maintained by the kpropd daemon, which receives the database content in
encrypted form from a program, kprop, which runs on the primary server.
Secondary databases can be updated by scheduling execution of a script,
/usr/kerberos/ run-kprop, in the root crontab.
The kpropd daemon listens for requests on the krb_prop /tcp port. If this port is
not defined in the /etc/services file, it uses port 754.
3.5.4 /etc/services File
The /etc/services file used on PSSP 2.1.0 is not consistent with the previously
discussed naming convention for the Kerberos daemon services.
kerberos
kerberos
kerberos-adm
kerberos-adm
rfile
loadav
pump
pump
qrh
qrh
rrh
rrh
tell
tell
88/tcp
88/udp
749/tcp
749/udp
750/tcp
750/udp
751/tcp
751/udp
752/tcp
752/udp
753/tcp
753/udp
754/tcp
754/udp
#
#
#
#
Kerberos
Kerberos
kerberos administration
kerberos administration
Figure 24. Extract from the /etc/services File
Users must be aware of these potential conflicts when using third party Kerberos
servers. If the kerberos and kadmind daemons are running, then the netstat -a
command should return the following:
root@sp21cw0
/ > netstat -a &pipe. grep loadav
udp
0
0 *.loadav
*.*
root@sp21cw0 / > netstat -a &pipe. grep pump
tcp
0
0 *.pump
*.*
LISTEN
Figure 25. Example Using netstat Command
3.5.5 Databases
The authentication database is created by the command kdb_init, which is called
from the setup_authent script. The authentication database is made up of two
binary files:
76
SP PD Guide
•
/var/kerberos/database/principal.pag
•
/var/kerberos/database/principal.dir
This soft copy for use by IBM employees only.
The Kerberos database contains the name of the authentication realm and all
the principals′ names and their keys. The database files can be converted to an
ASCII file by the script /usr/lpp/ssp/kerberos/etc/ kdb_util dump. Use kdb_util
load to convert the ASCII file back to binary.
3.6 Files
The files described in this section are used by Kerberos.
3.6.1 /.k
The master key cache file contains the DES key derived from the master
password. The master password is supplied initially by the administrator when
the primary authentication server is created. The corresponding DES key is
saved in /.k using the /usr/lpp/ssp/kerberos/etc/kstash command. The kadmind
daemon and the database utility commands read the master key from this file
instead of prompting for the master password. If the /.k file is deleted, these
commands will still execute successfully; however, the user will be prompted for
the master password. The kadmind daemon cannot be successfully respawned
if the /.k file is removed. The kstash command can be used to recreate the /.k
file. The user will, however, be prompted for the master password.
Note: Without a /.k file, the Kerberos server cannot be started automatically
during an unattended reboot of the master server.
3.6.2 $HOME/.klogin
The .klogin file contains a list of principals (name.instance@realm). This file
specifies the remote principals authorized to invoke commands on the local user
account. For example, the root user′s .klogin file contains a list of principals that
are authorized to invoke processes as the root user with the Kerberos remote
commands (rsh and rcp).
Notes:
1. Only add principals to root′ s .klogin file on the Control Workstation.
2. Do not delete any principals which already exist.
3. The root user must always have a .klogin file, and the root user must be
listed in the file.
4. The root .klogin is distributed to the nodes during installation or
customization. Use dsh to update the nodes′ .klogin file after changing it on
the Control Workstation.
3.6.3 /tmp/tkt<uid>
The tkt<uid> file contains the tickets owned by a client (user). The first ticket
in the file is the ticket-granting ticket. The ticket cache file is created when the
user executes the kinit command. The KRBTKFILE environment variable may
be used to change the default location and name for the ticket cache file. The
klist command displays the contents of the current cache file. The kdestroy
command deletes the current cache file.
Chapter 3. K e r b e r o s
77
This soft copy for use by IBM employees only.
3.6.4 /etc/krb-srvtab
The server key file, /etc/krb-srvtab, contains the names and private keys of the
local instances of Kerberos-protected services. During the setup of the Control
Workstation or the nodes, the keys for service principals are stored in the
authenticated database (for use by the authentication server) and in the file
/etc/krb-srvtab (for use by the services themselves). So, every node and the
Control Workstation includes an /etc/krb-srvtab file that contains the keys for the
services provided on that host. On the Control Workstation, the hardmon and
rcmd service principals are in this file:
root@sp21cw0
/ > klist -srvtab
Server key file:
/etc/krb-srvtab
Service
Instance
Realm
Key Version
-----------------------------------------------------hardmon
sp21tr0
SP21CW0
1
rcmd
sp21tr0
SP21CW0
1
hardmon
sp21cw0
SP21CW0
1
rcmd
sp21cw0
SP21CW0
1
Figure 26. Example of /etc/krb-srvtab from the Control Workstation
On the nodes, the rcmd service principals are in this file:
root@sp21n01
/ > klist -srvtab
Server key file:
/etc/krb-srvtab
Service
Instance
Realm
Key Version
-----------------------------------------------------rcmd
sp21n01
SP21CW0
1
Figure 27. Example of /etc/krb-srvtab from a Node
Note: Always ensure that the service keys contained in the authentication
database and in the /etc/krb-srvtab files on the nodes match. The
/usr/lpp/ssp/kerberos/etc/ext_srvtab command can be used to create new
server key files for each node.
3.6.5 /etc/krb.conf
The SP authentication configuration file, /etc/krb.conf, defines the local
authentication realm and the location of authentication servers for known realms.
The first line contains the name of the local authentication realm. Subsequent
lines specify the authentication server for a realm.
This file is created by the setup_authent script on the primary authentication
server. You may supply your own krb.conf file before running setup_authent if
you want to use a non-default realm name (the default realm name is the
domain portion of the primary authentication server′s hostname converted to
uppercase).
root@sp21n01
/ > cat /etc/krb.conf
SP21CW0
SP21CW0 sp21cw0 admin server
Figure 28. Example of a /etc/krb.conf File
78
SP PD Guide
This soft copy for use by IBM employees only.
3.6.6 /etc/krb.realms
This file maps a host name to an authentication realm for the services provided
by that host. Each line in the file must be in one of the following forms:
•
host_name
•
domain_name realm_name
realm_name
(Domain names should begin with a period)
sp21tr0 SP21CW0
sp21n01 SP21CW0
sp21n02 SP21CW0
sp21n03 SP21CW0
sp21n04 SP21CW0
sp21n05 SP21CW0
sp21n06 SP21CW0
sp21n07 SP21CW0
sp21n08 SP21CW0
sp21n09 SP21CW0
sp21n10 SP21CW0
sp21n11 SP21CW0
sp21n13 SP21CW0
sp21n15 SP21CW0
sp21sw01 SP21CW0
sp21sw02 SP21CW0
sp21sw03 SP21CW0
sp21sw04 SP21CW0
sp21sw05 SP21CW0
sp21sw06 SP21CW0
sp21sw07 SP21CW0
sp21sw08 SP21CW0
sp21sw09 SP21CW0
sp21sw11 SP21CW0
Figure 29. Example of a /etc/krb.realms File
This file is created (if it does not yet exist) by the setup_authent script on the
primary authentication server.
3.6.7 /var/adm/SPlogs/kerberos
There are two log files in the /var/adm/SPlogs/kerberos directory:
•
kerberos.log
•
admin_server.syslog
The kerberos.log file contains information relating to the kerberos daemon, such
as when it was started. It also contains error messages. Following is an
example of the kerberos.log file containing the error messages when the /.k file
is deleted.
Chapter 3. K e r b e r o s
79
This soft copy for use by IBM employees only.
26-Apr-96
26-Apr-96
26-Apr-96
26-Apr-96
26-Apr-96
26-Apr-96
14:48:04
14:48:25
14:48:25
14:48:25
14:59:21
15:19:11
Kerberos started, PID=17802
Kerberos started, PID=17818
kerberos: 2503-000 Could not read master key.
Kerberos will pause so as not to loop init
Kerberos started, PID=41620
Kerberos started, PID=57046
Figure 30. Example of kerberos.log File
The admin_server.syslog file contains information relating to the kadmind
daemon. It also contains error messages from the daemon. Following is an
example of the admin_server.syslog file containing the error messages when the
/.k file is deleted.
26-Apr-96
26-Apr-96
26-Apr-96
26-Apr-96
14:49:23
14:49:23
14:49:23
14:53:17
Kerberos
kadmind:
Shutting
Kerberos
admin server started, PID=57080
2503-101 error: 2504-317 Could not fetch master key
down admin server
admin server started, PID=22380
Figure 31. Example of admin_server.syslog File
3.7 Commands
This section describes the commands used by Kerberos.
3.7.1 kinit
The kinit command is used to authenticate a user to the Kerberos
authentication services. A ticket-granting ticket is created and stored in the
user′s ticket cache file (usually /tmp/tkt<uid>). All the user′s previous tickets
are destroyed.
The simplest way to invoke the kinit command is to specify the principal as the
only argument; for example:
kinit fred
kinit root.admin
3.7.2 klist
The klist command displays the principal name, the issuing time, and the
expiration time for each ticket held in the user′s current cache file. The
ticket-granting ticket is displayed first, followed by the various service tickets.
Following is an example of the output of the klist command.
80
SP PD Guide
This soft copy for use by IBM employees only.
root@sp21cw0
/ > klist
Ticket file:
/tmp/tkt0
Principal:
root.admin@SP21CW0
Issued
Apr 26 14:59:45
Apr 26 15:00:10
Apr 26 15:38:50
Apr 26 15:38:50
Apr 26 15:38:50
Expires
May 26 14:59:45
May 26 15:00:10
May 26 15:38:50
May 26 15:38:50
May 26 15:38:50
Principal
krbtgt.SP21CW0@SP21CW0
hardmon.sp21cw0@SP21CW0
rcmd.sp21n01@SP21CW0
rcmd.sp21n02@SP21CW0
rcmd.sp21n03@SP21CW0
Figure 32. Example of klist Output
The output lists the location of the principal′s current cache file, as well as the
principal′s full name. The first ticket is the ticketgranting ticket. The service
tickets are for the System Monitor service (hardmon) and for the SP Remote
Command service (rcmd) on nodes 1, 2, and 3.
The command klist -srvtab displays the local instances of services and their
private key versions found in the server key table (usually /etc/krb-srvtab).
Following is an example of the output of the klist -srvtab command.
root@sp21cw0
/ > klist -srvtab
Server key file:
/etc/krb-srvtab
Service
Instance
Realm
Key Version
-----------------------------------------------------hardmon
sp21cw0
SP21CW0
1
rcmd
sp21cw0
SP21CW0
1
rcmd
sp21tr0
SP21CW0
1
hardmon
sp21tr0
SP21CW0
1
Figure 33. Example of klist -srvtab Output
The output displays the key versions for service principals on the Control
Workstation.
3.7.3 kdestroy
The kdestroy command writes zeros to the user′s current ticket cache file and
then removes the file. As a result, all the user′s active authentication tickets are
deleted. For added security, you may wish to automatically destroy your tickets
when you log out.
3.7.4 kstash
The kstash command saves the system′s authentication database master key in
the master key cache file (/.k). The user is prompted to enter the master key to
verify the authenticity of the key and to authorize caching it.
Chapter 3. K e r b e r o s
81
This soft copy for use by IBM employees only.
3.7.5 dsh and p* Commands
The dsh command uses rsh to execute a specific AIX command on any group of
nodes or other remote RS/6000 hosts within the authentication realm, in parallel.
The group of target hosts may be pointed to by the WCOLL variable, which in
turn points to a file containing the hostname of each target host.
There are various p* commands ( p_cat, pcp, pdf, pfck), which all use dsh to
execute a specific AIX command in parallel on multiple hosts.
3.7.6 rsh and rcp
There is a Kerberos-authenticated version of both rsh and rcp in the
/usr/lpp/ssp/rcmd/bin directory. To use the Kerberos versions, the user must
include this directory before the /usr/bin directory in the local host′s PATH.
If the user′s authentication fails, the /usr/lpp/ssp/rcmd/rsh (or rcp) command
issues an error message and passes its arguments to /usr/bin/rsh (or rcp). In
this case the user will require normal remote command access to the remote
host (through /etc/hosts.equiv or $HOME/.rhosts).
3.7.7 sysctl
The sysctl command provides a command line interface for communicating with
the sysctl remote command execution and monitoring server, sysctld. Sysctl
connects to a remote host′s sysctld using TCP/IP, passes keywords and
commands to the server, and writes output returned to stdout. Any sysctl user
must be a Kerberos principal.
3.8 Solving Problems
There are a few basic things to check when Kerberos authentication fails. The
following hints and tips should be followed before taking the more drastic
measure of rebuilding the entire Kerberos database. Also consult Chapter 6,
“Diagnosing Authentication Problems,” in the RS/6000 Scalable POWERparallel
Systems: Diagnosis and Messages Guide , GC23-3899 for further information.
3.8.1 Daemons
Start by checking that both the kerberos and the kadmind daemons are running.
If the daemons are not running, then check /etc/inittab. The entries for these
two daemons should be similar to the following:
root@sp21cw0
/etc > lsitab kerb
kerb:2:respawn:/usr/lpp/ssp/kerberos/etc/kerberos
root@sp21cw0 /etc > lsitab kadm
kadm:2:respawn:/usr/lpp/ssp/kerberos/etc/kadmind -n
Figure 34. inittab Entries for Kerberos Daemons
If the /etc/inittab file is correct, then try to start the daemons from the command
line. Also check the Kerberos daemon log files in the /var/adm/SPlogs/kerberos
directory for any error messages, which may explain why the daemons cannot
be respawned.
82
SP PD Guide
This soft copy for use by IBM employees only.
3.8.2 Tickets
Confirm that the user is known to Kerberos and that the user has a valid ticket
for the requested service by runnig the klist command. Check that the user′ s
ticket cache file exists. If the ticket cache file is not in the default location
(/tmp/tkt<uid>), then see where the KRBTKFILE variable points. If the problem
appears to be due to invalid tickets, then use the kdestroy and kinit commands
to generate new tickets for the user.
Also check that the $HOME/.klogin file exists and that there is an entry for the
user (requesting the service) in the file.
3.8.3 PATH Variable
Ensure that the /usr/lpp/ssp/rcmd/bin directory is before the /usr/bin directory in
the user′s local PATH statement. Also make sure that the PATH variable is
exported.
PATH=/usr/lpp/ssp/rcmd/bin:$PATH:/usr/lpp/ssp/bin
:/usr/lpp/ssp/kerberos/bin:/usr/local
export PATH
Figure 35. Example of PATH Statement from .profile File
3.8.4 Configuration Files
Check and confirm that the contents of the /etc/krb.conf and /etc/krb.realm files
are correct.
SP21CW0
SP21CW0 sp21cw0 admin server
Figure 36. Sample /etc/krb.conf File
sp21tr0 SP21CW0
sp21n01 SP21CW0
sp21n02 SP21CW0
sp21n03 SP21CW0
sp21n04 SP21CW0
sp21sw01 SP21CW0
sp21sw02 SP21CW0
sp21sw03 SP21CW0
sp21sw04 SP21CW0
Figure 37. Sample /etc/krb.realms File
Chapter 3. K e r b e r o s
83
This soft copy for use by IBM employees only.
3.8.5 TCP/IP
Check that TCP/IP is functioning correctly by using the ping command to confirm
communication with the various adapters on each node. Also use the host
<hostname> and host <IP address> commands to ensure that hostname
resolution is correct (both commands must return the same output).
root@sp21cw0
/tmp > host sp21cw0
sp21cw0 is 9.12.60.99, Aliases:
sp21en0
root@sp21cw0 /tmp > host 9.12.60.99
sp21cw0 is 9.12.60.99, Aliases: sp21en0
Figure 38. Example of Host Name Resolution
3.8.6 Remote Principals
Ensure that the remote user or client has permission to invoke commands on the
local user account. If the originating remote user is authenticated to one of the
principals named in the .klogin file, access is granted to that account.
Note: If a klogin file is present, the owner must also be listed in order to gain
access to the user′s own account from a remote host.
3.8.7 Service Key Files
First check that the service key files (/etc/krb-srvtab) exist on all nodes. Use
either the ksrvutil or the klist command to show the version numbers of the
service keys in the /etc/krb-srvtab files.
root@sp21cw0
/etc > klist -srvtab
Server key file:
/etc/krb-srvtab
Service
Instance
Realm
Key Version
-----------------------------------------------------hardmon
sp21cw0
SP21CW0
1
rcmd
sp21cw0
SP21CW0
1
rcmd
sp21tr0
SP21CW0
1
hardmon
sp21tr0
SP21CW0
1
Figure 39. Example of klist -srvtab Command on the Control Workstation
The service key version numbers in the /etc/krb-srvtab files must match the
version number kept in the Kerberos authentication database. Use the
/usr/lpp/ssp/kerberos/etc/kdb_util command to dump the contents of the
authentication database to an ASCII file. The fifth field in this file is the service
key version number.
If there are any problems with the service key files, then they must be re-created
using the /usr/lpp/ssp/kerberos/etc/ext_srvtab command. See Chapter 6,
“Diagnosing Authentication Problems,” in the RS/6000 Scalable POWERparallel
Systems: Diagnosis and Messages Guide , GC23-3899 for further information.
84
SP PD Guide
This soft copy for use by IBM employees only.
3.8.8 PTF Levels
Ensure that the Control Workstation and all the nodes are at the same PTF level.
3.8.9 Rebuild the Kerberos Database
If all else fails, the Kerberos authentication database may be completely
re-created. The following steps may be used to achieve this.
Note: This procedure does not require the user to reboot the nodes.
1. Ensure the following directories are included in your PATH:
•
/usr/lpp/ssp/kerberos/etc
•
/usr/lpp/ssp/kerberos/bin
•
/usr/lpp/ssp/bin
2. kdb_destroy (delete the kerberos database)
3. kdestroy (delete all current tickets)
4. rm /.k (delete the master key cache file)
5. rm $HOME/.klogin
6. rm /etc/krb* (delete the Kerberos configuration files)
7. chitab “kadm:2:off:/usr/lpp/spp/kerberos/etc/kadmind -n”
chitab “kerb:2:off:/usr/lpp/spp/kerberos/etc/kerberos”
8. telint 2 (refresh inittab)
9. stopsrc -s hardmon
10. setup_authent
11. spbootins -r customize -l $NODELIST
(where $NODELIST is a comma-separated list of node numbers)
12. startsrc -s hardmon
13. telinit 2 - Restart the Kerberos daemons
14. ext_srvtab -n $NODENAMES
(where $NODENAMES is a comma-separated list of node names).
This creates files called <nodename>-new-srvtab in the current
directory). You should run this command against all interfaces, then
you should concatenate those file before transfer them to the nodes.
15. ftp the files created in Step 14 to their respective nodes.
Place the files in /etc and name them krb-srvtab.
16. Check that /etc/krb.conf has the entry rcmd.CWname.Realm
(where Realm is the realm specified in /etc/krb.realms).
17. Check /etc/krb.conf and /etc/krb.realms on all nodes.
(These files should be the same as the ones on the Control Workstation.)
18. From the CW: dsh -a id (Check that kerberos works.)
19. From the node1: dsh -w node2 id
20. spbootins -r disk -l $NODELIST
Figure 40. How to Rebuild the Kerberos Database
Chapter 3. K e r b e r o s
85
This soft copy for use by IBM employees only.
86
SP PD Guide
This soft copy for use by IBM employees only.
Chapter 4. The Switch
Most of the switch-related problems require a clear understanding of the switch
components. This chapter explains those components, gives examples about
configuration and topology files, and explains how to handle switch problems
and interpret switch log files.
4.1 Overview
In the following section, the term switch is used generically to cover both the
High Performance Switch and the new SP Switch. Where the comments apply to
only one of these switches, the appropriate name will be used.
The assumption is also made that the switch board described is not the LC8
Switch board which can be installed in the half height frames (49 inch frame);
this only provides connections to 8 nodes. This switch board will be discussed
in detail later on.
The switch consists of 3 main hardware components:
•
The switch board containing the switch chips
•
The switch cables to connect the switch to the nodes and other switches
•
The switch adapters for each node that is to be part of the switch network
Each switch board has 32 sockets available to connect to either nodes, or other
switches (that will be part of the same network). Sixteen sockets are available
for the nodes, and 16 sockets are available for the external communications to
the other switches.
These socket connectors are known as Jack Sockets , which are abbreviated in
much of the documentation to Jxx (where xx is the number that identifies a
particular socket).
J3 through to J34 are available for these types of communications. J1 and J2
are used for alternative communications, such as the serial connection. The
power source is the other usage of these connections.
Figure 41 on page 88 shows an example of these connections for the High
Performance Switch.
 Copyright IBM Corp. 1996
87
This soft copy for use by IBM employees only.
Figure 41. The HiPS Showing the External Connections
It is worth stating at this point that the Control Workstation is not part of the
switch network, and putting a switch adapter in the Control Workstation is not
supported in the current environment.
Setting aside the LC8 Switch for the time being, there are 2 main types of switch
boards that can be used:
•
Node switch boards
•
Intermediate switch boards
To explain why intermediate switch boards are required, it is necessary to return
to the comment made earlier that 16 jack connections are available for
communication with other switches. If you take the situation where there are 2
switches in the network, all 16 of these are available to connect to the other
switch (despite the fact that data will only flow down 8 of these). If there are 3
switches, then 8 cables will go to the first switch and 8 to the other.
The number of cables going to each switch decreases to the point where you
have 5 switches allowing only 4 cables to go to each switch. Having more than 5
switches in a configuration is not currently supported (although there is no
intrinsic reason why it cannot be done) because by having less than 4 cables to
connect each switch, the bandwidth of the network starts to be compromised.
The intermediate switch boards remedy this situation. Special frames that
contain only switches and their associated cables are required to house these
boards. These switch boards only communicate with other switches for which
there are all 32 jack connections available. Within these switch frames there are
always 4 intermediate switch boards, all of which are cabled to the node switch
boards for configurations up to the 128-way size. The 4 switch boards, with 32
connections each, make 128 connections possible.
88
SP PD Guide
This soft copy for use by IBM employees only.
Actually, for 128-way systems, while all 16 available connections on the node
switch boards are cabled to the intermediate switch boards (4 to each of the
ISBs), only half of these cables are actually used to transfer data. It is by taking
out these redundant cables and using the connection on this ISB to connect to
other ISBs that it is possible to go beyond the 128-way to larger switch sizes.
The jack socket on the NSB is covered with a blanking plate in this instance.
Figure 42 shows how ISBs are cabled for two of the four ISBs (the diagram
would be rather confusing if all 4 were included). In addition, there is reference
to connections between ISB frames. These are only required for systems larger
than the 128-way.
Figure 42. Example of the Cabling for a 128-Way System
The connectivity on 128-way systems is excellent because there are always 8
cables that data can travel down to reach the node frame. The intermediate
switch boards provide sufficient routes to ensure that this is an optimum
configuration. If a 128-way configuration was supported without the use of
intermediate switch boards, then only 2 cables could be used to connect the
majority of the switch boards and the bandwidth would be compromised.
When using the intermediate switch boards, there will be more hops required to
travel between the node switch boards because the route must always go
through one of these intermediate boards rather than directly from one node
switch board to another. This increases the latency of the network, but because
the latency is so low on the switch, this does not become a significant factor in
the speed of the network. The determining factor is whether there is contention
for routes. As soon as packets are delayed due to all available routes being
busy, then network delays occur. By using intermediate switch boards, packet
contention is kept to a minimum. In the hypothetical example given for a
128-way system with all switch boards directly attached, packet contention is
likely to occur on a more regular basis.
Chapter 4. The Switch
89
This soft copy for use by IBM employees only.
Figure 43 on page 90 gives an example of the cabling for a 3-switch system
without using intermediate switch boards.
Figure 43. Example of the Cabling on a 48-Way System
The exact cabling configuration will be addressed later (that is, which jack
connection goes to which node or other jack connectors on other switches), but
first the internal cabling on the switch board will be covered.
4.1.1 Software Overview
The High Performance Switch can be run at both PSSP 1.2 and PSSP 2.1. The
SP Switch, though, can only be run at PSSP 2.1 and only with a certain level of
maintenance applied. To check your current level of maintenance, execute:
# lslpp -l | grep ssp
If you have to install the SP Switch, ensure that the following two products are at
least at the levels specified below:
ssp.basic
ssp.css
2.1.0.10
2.1.0.8
SP System Support Package
SP Communication Subsystem
This level of code is known as PTFset11. In fact, the levels should be higher
than this to avoid the known problems that can be associated with
newly-supported devices.
If the High Performance Switch is installed, the level of maintenance shown
above (ssp.basic 2.1.0.10 and ssp.css 2.1.0.8) is perfectly valid. It provides
support for both types of switches.
You may also use CSS_test command to verify that the same PSSP level is
installed on the nodes and on the Control Workstation.
90
SP PD Guide
This soft copy for use by IBM employees only.
4.1.2 High Performance Switch and SP Switch Coexistence
Note
In the current environment, it is not possible for the High Performance Switch
and the SP Switch to coexist within the same RS/6000 SP system. If there is
a requirement to install a new SP Switch without migrating the existing High
Performance Switch, then a new system, which has its own Control
Workstation and its own SP environment, is required.
The cabling is slightly different on the SP Switch. The jack connectors are now
associated with different nodes and different jack connectors on other switches.
For example, Node 14 (N14) is connected to the switch board at J4 on the High
Performance Switch, but on the SP Switch it is connected at J34.
The topology files which describe the cabling are still the same.
Systems with the SP Switch installed do not support system partitions with nodes
that have anything less than the required software levels specified earlier (that
is, PSSP 2.1 with PTF set 11). The support is provided at this level, and so AIX
Version 3.2.5 partitions are not possible in this environment.
From the application perspective, no changes should be required when moving
to the SP Switch environment. Functionally, the switch looks the same to the
application. For example, it has the same topology, and the same structure.
4.1.3 Comparing HiPS and SP Switch
•
Both switches are packet switches with wormhole routing.
Packet switches with wormhole routing help balance low latency and help to
relieve of congestion problems. Circuit switches open the entire path from
sending node to receiving node and keep that path through a whole
message. This reduces latency and guarantees delivery, but it also locks up
resources and can cause heavy congestion. Packet switching only locks up
a resource for the time of a packet. Using wormhole routing reduces latency
because it allows you to start sending a packet as soon as a receive buffer is
available. However, when a packet gets blocked downstream, it can back up
through several switch chips and start to have congestion problems. So, by
using packet switching with wormhole routing, latencies are reduced.
•
The board is still 16x16x2.
There are 16 ports on one side of the board that are connected to four chips.
These four chips are connected to four chips on the other side of the board,
which are in turn connected to 16 ports that also leave the switch assembly.
So, now you can picture the 16x16. The “2” comes from the ports being
duplex; data passes in both directions. Figure 42 on page 89 and Figure 43
on page 90 show examples.
•
Global synchronous clocks.
Global synchronous clocks allow you to easily keep the same Time of Day
(TOD) across the system. This helps applications and fault isolation. If a
particular error is propagated through a system (for example, if there is a
bad Error Detection Code (EDC) on some data), you can now see it first by
comparing the time stamp on various switch chips′ error register. This will
allow you to determine where the problems first occurred.
Chapter 4. The Switch
91
This soft copy for use by IBM employees only.
The problem that you have with global synchronous clocks is that if the
master fails, the entire system goes down. SP Switch has improved
recoverability by putting two oscillators on each board. However, the
switchover will probably still be a manual process for a while. This is
because switching to a new oscillator will bring down the system. If the
hardware and software incorrectly sense that there is a clock problem, this
could bring down the whole system for no good reason. Until we have a
better handle on how to always correctly determine that a clock failure has
occurred and we can always correctly determine how to recover, we will
leave this up to a human operator who has a better understanding of the
state of the user applications when the system is brought down.
•
They use the same topology files
The topologies in HiPS are extremely scalable, so the SP Switch uses the
same files. Eannotator must be run over the topology files to update the new
wiring. Refer to 4.5, “Switch Commands” on page 104.
•
They have the same mechanical factor
4.1.4 Improvements of SP Switch over HiPS
•
Faults are not global
The HiPS had global faults. When a fault occurred, a fault code was
propagated throughout the entire switch network until all of the links were
brought down and had to be reinitialized. This is a remnant of the original
design point of the HiPS switch as it was designed in research. The original
machine was only supposed to be running a single application.
With SP Switch, we had time to redesign the fault scenarios and we made
the faults localized. Only the link that experienced the fault is brought down.
It can then be brought back online with minimal disturbance to the system.
You will be glad to know that taking a node offline will no longer bring down
the entire switch.
•
No more chip shadowing
The HiPS used two physical chips to perform the function and checking of
one logical chip. The second chip checked the operation of the first chip.
This is a very thorough way to detect errors. However, it is also very
expensive. You have to add some circuitry to check the other chip and you
use two chips. By adding a little more circuitry to one chip, you can do
checking that is almost as good, but a lot cheaper. The architecture of the
system (with EDC and CRC on the messages) also helps check messages for
errors. What is lost is a little fault isolation. For that we get a less
expensive design with better reliability (fewer parts to break).
•
Cable clips on; not screwed in
An annoying problem with HiPS was that each of the 32 cable/wrap plugs on
a switch had to be screwed in: 2 screws on 32 cable is 64 screws. This
slowed down installing and servicing the switch. It also caused some sore
wrists for people installing large systems. SP Switch addressed this by
putting clips on the connectors instead of screws. Now, clips are not perfect.
They are not seated as surely as screws are. You also will have a small
pitch between connectors, so getting your fingers in to work the clips is not
necessarily a simple task.
•
92
SP PD Guide
Estimated 12.8 times better reliability
This soft copy for use by IBM employees only.
With newer technology, the SP Switch is more reliable that HiPS. Also, fewer
parts improves the reliability. The function of the HiPS 32 driver/receiver
chips embedded in the SP Switch chips. This is also true of most of the
clocking logic. The SP Switch board is basically eight switch chips, two
oscillators and four phase-locked loop (PLL) chips. Of course, you still have
terminating resistors and decoupling capacitors.
•
N+1 power supplies and fans
The N+1 power supplies and fans will help availability and allow you to
defer maintenance on failed components to a more convenient time.
•
150 MBps single direction bandwidth
The switch provides 150 MBps single direction bandwidth (300 MBps both
directions). This is nominal bandwidth. The effective bandwidth will change
according to the different protocol stacks used to transfer data.
•
The link is more advanced
Internal and external links have a more advanced technology that provides
greater speed, and that can also adjust itself better to drifts in the clock/data
relationship that are caused by things like temperature changes and
component variations caused by age.
4.2 Reviewing Switch Boards
The following sections reviews switch board information, as illustrated in
Figure 44.
Figure 44. The HiPS Board
J3 to J34
Bulkhead jacks for data cables
V1 to V32
Data connectors on the switch board
Chapter 4. The Switch
93
This soft copy for use by IBM employees only.
SW0 to SW7
Logical identification of switch chips
•
•
In output files, add 10,000 to the logical number.
The frame number is used to build the logical number multiply frame number by 10.
SWA1 to SWA8 Master switch chip silkscreen on the board
N1 to N16
Node ports (physical numbering)
E1 to E16
Switch to switch ports
Each switch board contains eight logical switch chips. In fact, on the High
Performance Switch, there are two physical chips per logical switch chip. Each
chip has eight ports to communicate with the nodes, other switch chips, or other
switches.
The switch chips numbered SW4, SW5, SW6 and SW7 handle all the
communications with the nodes using chip ports 0, 1, 2 and 3. The other four
chip ports (4, 5, 6 and 7) are used to communicate with the other switch chips:
SW0, SW1, SW2 and SW3. By routing across to these four chips on the other
side, it is possible for each of the chips that service the nodes to reach the other
three node chips through four different routes.
The following example illustrates this concept.
To communicate from node 14 (N14) to node 16 (N16), the path that a packet
could take is as follows:
•
The packet passes SW4 through port 0, and can exit the switch chip through
the following four routes, which are the chosen routes:
1. Port
over
2. Port
over
3. Port
over
4. Port
over
•
7 across to SW3,
to SW7, onto the
6 across to SW2,
to SW7, onto the
5 across to SW1,
to SW7, onto the
4 across to SW0,
to SW7, onto the
onto
chip
onto
chip
onto
chip
onto
chip
that chip
on port 7
that chip
on port 6
that chip
on port 5
that chip
on port 4
through port 4, exiting on port 7,
through port 4, exiting on port 7,
through port 4, exiting on port 7,
through port 4, exiting on port 7,
Once onto SW7, it will exit through port 3, go through J34 onto the cable, and
onto the switch adapter on node 16 (N16).
This mechanism ensures that there are four routes between each node on a
single switch board in a single partition system.
The switch chips SW3, SW2, SW1, and SW0 handle the communications to the
other switch chips, as well as providing the four routes between all the nodes as
just described. These chips handle the communications to the other switch
boards on ports 0, 1, 2, and 3 (which are unused on a single switch system) and
using ports 4, 5, 6, and 7 to communicate with the chips that connect directly to
the nodes (SW4, SW5, SW6, and SW7).
The connections to other switches will vary, depending on how many switches
are being connected. This will be dealt with later after the switch topology files
have been discussed.
The cabling is slightly different on the SP Switch. The jack connectors are now
associated with different nodes and different jack connectors on other switches.
94
SP PD Guide
This soft copy for use by IBM employees only.
For example, Node 14 (N14) is connected to the switch board at J4 on the High
Performance Switch, but on the SP Switch it is connected at J34. Look at
Figure 45 on page 95 and compare it with Figure 41 on page 88 for the High
Performance Switch to discover how it is cabled differently.
Figure 45. The SP Switch Board
J3 to J34
Bulkhead jacks for data cables
V1 to V32
Data connectors on the switch board (silk screen)
SW0 to SW7
Logical identification of switch chips
•
•
In output files, add 10,000 to the logical number.
The frame number is used to build logical number. Multiply
frame number by 10.
U1 to U8
Master switch chip silkscreen on the board
N1 to N16
Node ports (physical numbering)
E1 to E16
Switch to switch ports
4.3 Switch Topology and Clock Subsystem
The following section discusses switch topology and clock subsystem
considerations.
4.3.1 Switch Topology Files
The switch topology file is critical to the successful working of the switch. The
switch daemons (which will be discussed in some detail later) use this topology
file as the basis for creating the routing tables which get propagated to every
node on the switch network. The topology files are shipped as standard with the
POWERparallel System Support Programs software, and during the installation
Chapter 4. The Switch
95
This soft copy for use by IBM employees only.
process, you are required to choose the appropriate one, based on the number
and type of switch boards that you have installed.
The file expected.top. NSBnum nsb. ISBnum isb. type located on the Control
Workstation describes the wiring configuration for the switch. The switch
topology file naming convention is as follows:
expected.top. NSBnum nsb. ISBnum isb. type
Where:
NSBnum
(NodeSwitchBoard Number) is the number of NSBs in the
configuration
ISBnum
(Intermediate SwitchBoard Number) is the number of ISBs in the
configuration
type
This is the type of topology. The default is 0.
Note: This file must not be changed; otherwise the configuration is not
supported. All RS/6000 SP systems are cabled in a standard way that follows
the wiring set out in the topology files. This pattern of cabling or the contents of
the topology files should only be changed for diagnostic purposes on the advice
of an IBM engineer.
NSBs are switches mounted in frames containing nodes. ISBs are switches
mounted in switch expansion frames. ISBs are used in large systems to connect
many processor frames together so that bandwidth is not compromised on the
switch network.
Following is a listing from the /etc/SP directory on the Control Workstation.
While the Eclock files reside in this directory at PSSP 2.1, the topology files are
merely symbolic links to the directory:
/spdata/sys1/syspar_configs/topologies
In PSSP 1.2, these files did reside in the /etc/SP, but the change was made to
make the directory structure consistent with System Partitioning that was
introduced in PSSP 2.1.
[root@sp21cw0] /etc/SP > ls
Eclock.top.1nsb.0isb.0
expected.top.1nsb.0isb.0
Eclock.top.1nsb_8.0isb.0
expected.top.1nsb_8.0isb.0
Eclock.top.2nsb.0isb.0
expected.top.1nsb_8.0isb.1
Eclock.top.3nsb.0isb.0
expected.top.2nsb.0isb.0
Eclock.top.4nsb.0isb.0
expected.top.3nsb.0isb.0
Eclock.top.4nsb.2isb.0
expected.top.4nsb.0isb.0
Eclock.top.5nsb.0isb.0
expected.top.5nsb.0isb.0
Eclock.top.5nsb.4isb.0
expected.top.5nsb.4isb.0
Eclock.top.6nsb.4isb.0
expected.top.6nsb.4isb.0
Eclock.top.7nsb.4isb.0
expected.top.7nsb.4isb.0
Eclock.top.8nsb.4isb.0
expected.top.8nsb.4isb.0
The active topology file for a system partition contains within it the data required
by CSS switch code to maintain the switch fabrics. In particular, it contains
representations of:
96
SP PD Guide
•
All (possible) available frames of the system
•
All (possible) available nodes of the system
•
All (possible) available switch boards of the system
This soft copy for use by IBM employees only.
•
The board, switch chip and port at which each node is attached
•
The chip-to-chip connections within each board, including port data
•
The interboard connections, including chip and port data
The contents of a given topology file are enhanced by running Eannotator against
it. This adds comments to the records of the file, namely jack information which
help the reader and CSS switch code in understanding the cabling between
elements of the system. Eannotator embodies an understanding of the cabling
used in the system of a given switch type.
format 1
16 18
# Node connections in frame L01 to switch 1 in L01
s 15 3 tb0 0 0
L01-S00-BH-J18 to L01-N1
s 15 2 tb0 1 0
L01-S00-BH-J16 to L01-N2
s 16 0 tb0 2 0
L01-S00-BH-J20 to L01-N3
s 16 1 tb0 3 0
L01-S00-BH-J22 to L01-N4
s 15 1 tb0 4 0
L01-S00-BH-J14 to L01-N5
s 15 0 tb0 5 0
L01-S00-BH-J12 to L01-N6
s 16 2 tb0 6 0
L01-S00-BH-J24 to L01-N7
s 16 3 tb0 7 0
L01-S00-BH-J26 to L01-N8
s 14 3 tb0 8 0
L01-S00-BH-J10 to L01-N9
s 14 2 tb0 9 0
L01-S00-BH-J8 to L01-N10
s 17 0 tb0 10 0
L01-S00-BH-J28 to L01-N11
s 17 1 tb0 11 0
L01-S00-BH-J30 to L01-N12
s 14 1 tb0 12 0
L01-S00-BH-J6 to L01-N13
s 14 0 tb0 13 0
L01-S00-BH-J4 to L01-N14
s 17 2 tb0 14 0
L01-S00-BH-J32 to L01-N15
s 17 3 tb0 15 0
L01-S00-BH-J34 to L01-N16
# On board connections between switch chips on switch 1 in Frame L01
s 14 7
s 13 4
L01-S00-SC
s 14 6
s 12 4
L01-S00-SC
s 14 5
s 11 4
L01-S00-SC
s 14 4
s 10 4
L01-S00-SC
s 15 7
s 13 5
L01-S00-SC
s 15 6
s 12 5
L01-S00-SC
s 15 5
s 11 5
L01-S00-SC
s 15 4
s 10 5
L01-S00-SC
s 16 7
s 13 6
L01-S00-SC
s 16 6
s 12 6
L01-S00-SC
s 16 5
s 11 6
L01-S00-SC
s 16 4
s 10 6
L01-S00-SC
s 17 7
s 13 7
L01-S00-SC
s 17 6
s 12 7
L01-S00-SC
s 17 5
s 11 7
L01-S00-SC
Figure 46. Topology File Sample
The following is an example of how to interpret the lines in the topology file
shown in Figure 47 on page 98.
Chapter 4. The Switch
97
This soft copy for use by IBM employees only.
Figure 47. Topology File - Example
Comparing the HiPS and SP Switch boards, as shown, we see that the
node-to-switch port connections for SP Switch are the same as for HiPS. The
intra-switch connections are also the same. The only difference that would
impact the topology file information is the jack (cabling) information. Table 6
summarizes those differences.
Table 6. Cabling - SP Switch versus HiPS
Chip
Node
HiPS Jacks
SP Switch Jacks
Chip
Node
HiPS Jacks
SP Switch Jacks
3
-
3
3
4
14
4
34
5
4
13
6
33
7
5
10
8
32
9
6
9
10
31
11
27
6
12
10
13
28
5
14
9
15
29
2
16
8
17
30
1
18
7
19
11
3
20
26
21
12
4
22
25
23
13
7
24
24
25
14
8
26
23
27
19
11
28
18
29
20
12
30
17
31
21
15
32
16
33
22
16
34
15
2
1
0
98
-
-
-
SP PD Guide
5
6
7
This soft copy for use by IBM employees only.
4.3.2 Topology File Nomenclature
Figure 48. Topology File Nomenclature
Logical Notation
The logical notation has three fields that define one end of the cable and three
fields that define the other end. An end of the cable is defined as
<devices><logical number><port>, where:
•
Devices are s(switch), tb0 or tb2 (adapters). The names tb0 and tb2 are
generic for adapters and do not imply which type of adapter. It is actually
more an indication of when the topology was put together for release (SP1 or
SP2 time frame).
•
The logical number for switch chips has as many as three aspects: (1) the
last significant digit is the switch chip on the switch. This can be 0 through
7, because there are 8 switch chips; (2) the switch number; (3) if this is a
switch in a switch frame, 1000 is added to the logical number to differentiate
it from node frame switches. The switch frame switches are numbered 1
through the total number of switch frame switches. In other words, switch
frame 1 houses switches 1 through 8, and switch frame 2 has switches 9
through 16, and so on. A number like 11 tells you switch chip 1 on switch 1.
A number like 1023 tells you switch chip 3 on switch frame number 2.
•
The logical numbering for the adapters begins with 0. Each number is tied to
a specific node jack on a specific logical switch. If that node does not exist
in the system, that logical adapter is simply ignored by the system. In the
out.top log file, it will be noted as being replaced by a wrap plug.
•
The port number for switch chips can be 0 to 7, because there are eight
ports on a switch chip. Four ports leave the switch assembly and four ports
go to the other chips within the switch assembly.
•
The port number is always 0 for adapters.
Chapter 4. The Switch
99
This soft copy for use by IBM employees only.
4.3.3 HiPS Clock Subsystem
Understanding the switch clock subsystem will help you to get a better
appreciation of how various failures in the clock tree could cause certain
patterns of errors to arise in the log files.
•
The HiPS clock subsystem
The clock subsystem is divided in two parts: (1) The clock card and (2) The
switch card. The clock card has an onboard oscillator and three inputs
coming from the switch card data connectors that correspond to J3, J5, and
J7 of the bulkhead. It redrives the selection of one of those four inputs. The
redrive destination is the HiPS 3.0 card. There are also some redrives to J1
and J2 on the clock card. These were used by HiPS 2.0 switches (which, as
you recall, have external clock cables), rather than embedded in the data
cables.
Figure 49. The HiPS Clock Subsystem
The clock is driven from the clock card selection logic to the switch card.
From there, it is redriven to two major branches: one drives the data cables
and the other drives the switch chips.
Each data cable has a clock put on pins 37 and 38. The cable twists these to
the input pins 13 and 14 on the other side.
Of course, as mentioned earlier, only J3, J5, and J7 on the switch are used
for the inputs, and each node gets a copy of the clock. The clocks that do
not end up at nodes or at J3, J5, or J7 are terminated at the connector that
receives them; there is a 100 ohm resistor across pins 13 and 14 of the data
connector.
You can see how these are redriven by looking at the third part of the
picture. From the clock card you have a branch at level A, which is divided
into four branches in level B. Each branch is driven by a different redrive
chip. Note that the odd jacks J3 to J17 are on one branch, while the odd
100
SP PD Guide
This soft copy for use by IBM employees only.
jacks J19 to J33 are on a different branch. If none of the jacks have a clock,
then the problem most likely stems back to level A, or back to the clock card,
or even back to the switch that is supposed to be driving that clock card.
Now, if none of the even jacks (J4 through J18) have clocks on them, which
could be indicated by the diagnostics on all of the nodes connected to these
jacks, you can be pretty sure that is the B level redrive chip that has broken.
You can imagine the diagnostic power that you derive from knowing the
clock tree.
Figure 50. The HiPS Chip Clock Tree
First, the clock is put through a delay tap. The delay tap breaks the clock into
eight phases, which are later used to tune the individual switch port. Each of the
eight phases is driven to each of the switch chips. You can see how switch chip
0, 1, 6, and 7 are all redriven from one source and chips 2, 3, 4, and 5 are
redriven from another. If you get failures trying to talk with all four chips on a
single branch, and the others look okay, you can be pretty sure that the cause is
the chip which redrives their clock.
Basically, when you get massive errors, look for patterns that match the clock
redrive patterns, and you may be able to quickly narrow down your culprit.
4.3.4 SP Switch Clock Subsystem
The TBS board supports the use of multiple clock sources:
•
Two internal oscillators (attached to two of the board′ s
•
One of two possible external (HiPS-like) clock inputs:
−
−
To be used for a center of the room clock source, or “dual switch” clock
source, or both
Currently only one external connection is supported
Chapter 4. The Switch
101
This soft copy for use by IBM employees only.
Figure 51. The High Performance Switch Board
Further, each phase-locked loop provides a clock redrive function, and any
selected clock signal is passed through one of these redrives being distributed
to all switch chips on board.
Each source must pass through one PLL, and for each PLL we have:
(2 internal) + (32 ports) + (2 external) = 36 choices per PLL
so there are (4 PLL)x36 = 144 total possible clock source paths. However, in
the case of a port-sourced clock, the shortened systemwide clock-source path
protects against excessive STI retime by restricting the (PLL, port)-pair usage to
the “same chip.” (This minimizes the intra-board clock distribution path length
for each non-master board.) Hence, the number of port choices is reduced to
four for each PLL, and for a node switch board only non-node chips may be a
source, yielding:
(2 PLL) x [(2 internal) + (4 ports) + (2 external)] = 16 total allowed choices.
Each one of the internal oscillators encompasses a clock redrive, and any
chosen clock source must pass through one of these.
Currently only one external connection is supported.
4.3.5 Switch Clock Files
For the SP Switch, switch clocks in the system clock tree must be set in an
“ascending level” fashion, with a reset of each switch along the way. Hence, a
SP Switch Eclock topology file will contain a column indicating the level of the
subject switch within the distribution tree.
The two types of reset which may be performed on a SP Switch are described in
the following section. A POR is automatically performed when a switch is
102
SP PD Guide
This soft copy for use by IBM employees only.
powered. A synchronous reset is performed by the switch supervisor microcode
each time the clock source (PLL or mux) is set.
•
Power-on reset (POR)
−
−
−
−
•
Flush registers (zero all bits)
Self-test
Flush registers
Synchronous reset
Synchronous test
−
−
Error enables off
Clear errors
Multiple clock tree alternatives will be available in an Eclock topology file, and
so the successive alternatives will be presented one after the other.
4.4 Node Behaviors
The SP nodes can adopt different personalities when they are being part of the
switch network.
4.4.1 Primary Node Behavior
The switch commands are issued on the Control Workstation. These commands
tell the primary fault-service daemon to carry out the command.
The primary node considers the backup primary invalid if at least one of the
following is true:
•
The primary node has received an Error/Status packet from the backup′ s
switch port, and subsequent attempts to contact the backup fail.
•
The primary node has received a bad Error/Status packet from a scan of the
network, and subsequent attempts to contact the backup fail.
If the primary detects the backup has failed, it will automatically bring up a new
one. The new backup will be chosen such that it is as “far” away from the
primary as possible, in terms of the switch and physical node location (that is, on
a different switch). The intent is to make the probability of simultaneous primary
and backup failures as low as possible.
When a switch chip detects a condition the primary should know about, it sends
both Error/Status packets to the primary, to virtually guarantee that the primary
receives the Error/Status packet at least once. The two Error/Status packets
take routes that are disjointed, with the exception of the last hop, which links to
the primary node itself.
4.4.2 Primary Backup Node Behavior
The primary backup node has two duties. First, the primary backup node detects
the loss of the primary node and initiates the takeover processing. Additionally,
but usually the duty it is performing the most, the primary backup node functions
as any other secondary node.
The backup daemon will start a thread that will queue a request token if it has
not received a packet from the primary in M seconds, where M = 300 by default,
and it is called in the primary′s scan interval. When the daemon receives the
Chapter 4. The Switch
103
This soft copy for use by IBM employees only.
token, it will verify if it is still the backup before it takes over for the primary.
The backup daemon cancels this thread when it is no longer the backup.
4.4.3 Secondary Node Behavior
Every node, including the primary and the backup primary, executes the
following steps in order to start up the switch:
1. Builds the “ i d e a l ” database based on the topology file
2. Modifies the “ i d e a l ” database based on “ d e l t a s ” received from the primary
node
3. Calls the route table generator to build the routes from this node to all other
nodes
4. Tells the switch protocols (IP and User Space) which destinations are (or are
not) available
5. Loads the routes down to the adapter
The deltas are messages indicating uninitialized/fenced nodes and/or
uninitialized/fenced links received from the primary node.
For the most part, the secondary node repeats steps 2 through 5. The first step
applies only on IPL or when the topology file is changed (such as with switch
partitioning).
Secondary nodes send/receive service packets to/from the primary node only:
The secondary node acknowledges the primary node for each database delta
message it receives from the primary node.
4.4.4 Recovery from a Switch Failure
If a switch fabric or node failure occurs, the primary node must log the incident,
and decide whether the active configuration must be adjusted to render the “ill”
component(s) inactive. If the failing component is a switch link, the route table
must be updated so the faulty link is no longer used. If a non-primary node is no
longer reachable, the primary will fence that node.
If the primary node fails, the primary-backup must “take over.” It must:
•
Fence the primary
•
Assume the primary personality
•
Choose a new primary
•
Run switch initialization
4.5 Switch Commands
Eannotator
- Annotates the connection labels onto the topology file.
Figure 47 on page 98 shows some of the connection labels in a topology file.
Below is an example of a connection label:
L01-S00-BH-J18 to L01-N1
104
SP PD Guide
This soft copy for use by IBM employees only.
The system only uses these labels when reporting errors in the error log or the
css logs. If these labels are incorrect, then it will be difficult to debug problems
because the errors may be attributed to the wrong node.
Eannotator physically checks which connections it is going through (that is, the
jack socket or the switch chip connection) to get to a node or switch chip and
will update the topology file accordingly. It converts what is initially logical
information to actual physical information. For example, L06 for logical frame 6
may be converted to E8 because this may be the 8th physical frame.
After migrating to the SP Switch, it is essential to run Eannotator after the
hardware installation because the jack connections have changed completely
from those which were used for the High Performance Switch. The system does
not use this information during initialization, needing only the logical data to the
left of this in the file which describes each link on the network.
Eannotator is run after the topology file has been selected as part of the
installation process.
Etopology
- Stores or reads a switch topology file into or out of the SDR.
After the switch topology file has been annotated, it will be stored to the SDR by
Etopology during the installation process. The switch topology file stored in the
SDR can be overwritten by having an expected.top file in /etc/SP on the primary
node.
Estart
- Starts the switch
If Estart can find the file expected.top file in /etc/SP on the primary node, it will
use that to initialize the switch. Otherwise it will transfer the one stored in the
SDR on the Control Workstation to that directory on the primary node. Estart_sw
is run on the primary to initialize all the nodes in the switch. For the High
Performance Switch this process will then clean up the topology file that was
placed in its /etc/SP directory so that a new one will get transferred at the next
Estart.
If the switch fails to initialize all nodes for any reason, always check to see if
there is a /etc/SP/expected.top file on the primary node. If there is, check to see
if it is the correct topology file, and that its contents are valid. For the High
Performance Switch the only reason one of these files should exist is if an IBM
engineer wishes to temporarily override the topology file in the SDR to assist in
the diagnosis of a possible hardware failure on the switch. Once that work has
been completed, the file should be removed and the SDR file should be used.
Check to see if any of these files exist on any of the nodes by running:
# dsh -a ls -l /etc/SP/expected.top
If one of these files exists, then check it out because if the primary is changed to
that node, it may affect the initialization of the switch.
For the SP Switch, this procedure is different. A check is made to see whether
there has been a change in the switch topology by referencing the SDR, and if
this is not the case it uses the existing topology that has been previously
Chapter 4. The Switch
105
This soft copy for use by IBM employees only.
distributed. The cleanup of the /etc/SP/expected.top is not carried out for this
switch. If there has been a change, then the new topology file is copied into
/etc/SP on the primary. This topology file is further distributed on to the nodes
(through the boot/install servers, if there are any).
Eclock
- Controls the clock source for each switch board within a RS/6000 SP.
The clock source topology file (located in /etc/SP on Control Workstation) is
selected during installation of the system. Eclock uploads the mux values to
each switch board, which tells it where it will get its clock source, and then does
a reset on the board to resynchronize the switch chips. This is disruptive to
normal operations on the switch and care should be taken when this command
is run so that data is not corrupted or lost.
Efence
- Removes a SP node from the current active switch network.
For the High Performance Switch after a request to fence a node is issued, the
switch adapter is flagged that the request has been made to come off the switch
network. The Worm on the primary node is notified by a service packet during
service phase (see Eduration below), and it creates a new routing table based on
the fact that the link to the node is not included. The Worm on the primary then
distributes these to the nodes. In this way the link to the node is disabled. The
nodes are not able to generate a switch fault by sending a packet to the fenced
node, and so the switch fabric does not get disrupted.
With the SP Switch, the routes are not distributed over the network; only the
changes to the device database are. This database contains a listing of the
active nodes for that partition (that is, it does not include nodes that are fenced
or off the network). If a node is fenced with the autojoin option, then it is
included in the list of active nodes because it is ready to rejoin the network at
the next Estart. Any disabled links will be also flagged in this database. The
primary Worm will then generate a new routing table to download onto its SRAM
on the TB3 adapter. It will communicate the changes in the database as a delta
(that is, it will not send the entire database) to the other nodes. The Worm
daemons on the nodes are able to compute the routes locally for loading onto
the SRAM on the switch adapters.
Eunfence
- Adds a SP node to the current active switch network that was previously
removed with the Efence command.
Efence and Eunfence allow you to plan maintenance on a node and smoothly take
it on- and off-line with minimal effect on the switch network. By default, every
two minutes the switch network goes into service phase and looks for a node to
fence or unfence (see Eduration).
106
SP PD Guide
This soft copy for use by IBM employees only.
Figure 52. Diagram of the Different Phases on the High Performance Switch
Read the section on switch logs and also the following information, which gives
some indication of how this problem has occurred.
There are multiple ports called out by switch chips in the
/var/adm/SPlogs/css/flt. This rarely happens on real faults. When the chip can
narrow down to a single port, there is usually only one port that breaks. The
exception would be when multiple ports on a chip are connected to the same
switch, which has been powered off. This indicator is particularly interesting
when you start seeing random ports being reported over time (for example, ports
0, 1, and 7 reported at one time and ports 0, 1, and 6 reported at another time).
Another strong indication of this problem is that multiple onboard switch ports
(ports 4, 5, 6 and 7) are reported. Recall that these connect to different chips on
board.
The adapters may report MSTAT=12345678 or 000000080.
A message like: run_phase_transition: message not sent in time, may be
generated. The next fault seen is likely to be caused by this timeout.
If there is a problem with switch faulting and there are symptoms like those
described above, then contact the local IBM Support Center and mention APARs
IX53234 and IX54543.
Additional Information
Important
This applies only to the HiPS. The new SP switch does not have a service
phase.
Chapter 4. The Switch
107
This soft copy for use by IBM employees only.
4.5.1 The rc.switch Script
The rc.switch is run from the /etc/inittab during boot.
Whenever there is a problem initializing any of the nodes onto the switch, check
that the Worm daemon is running on the relevant nodes:
# ps -ef | grep Worm
If it is not running, then start it by running rc.switch script and check to ensure
the daemon stays up. If the Worm daemon is not running on the primary, then
none of the nodes will be initialized.
Always check the /var/adm/SPlogs/css/rc.switch.log to see any abnormal
behavior.
The content of various switch log files will be explained later in this section.
The /usr/lpp/ssp/css/ifconfig command configures or displays the network IP
interface parameters for the switch.
Always use this command in conjunction with the switch (css0 device) as
modifications had to made over standard TCP/IP implementation of AIX for this
network. Run the following command on the nodes to check that the css0
interface is up and all the nodes have the same attributes.
# dsh -a /usr/lpp/ssp/css/ifconfig css0
Ensure that there no inconsistencies. For example, when a node does not have
ARP enabled when others do, it may not be possible to even ping that node.
Run the following command to resolve this on that node:
# /usr/lpp/ssp/css/ifconfig css0 <switch IP address> arp
A detailed flow chart of this script can be found on Appendix A, “RS/6000 SP
Script Files” on page 229 under A.4, “The rc.switch Script” on page 262.
4.5.2 Switch Initialization
/usr/lpp/ssp/css/Estart_sw is called by /usr/lpp/ssp/bin/Estart script, and is
run only on the primary node (oncoming for SP Switch). It is useful to know that
the timeout variable LIMIT for the Estart command is located in this file. This
may have to be adjusted for systems that take longer than the default (180 sec).
Related Problem That Has Been Experienced:
The daemon must have enough time to go around and touch all of the switch
resources in the system. Due to heavy load on the primary node, there is a
possibility that the daemon will not finish the job within a timeout window. If the
timeout is reached, the switch network may experience switch faulting. The
problem has been experienced on systems that have primary nodes with heavy
Micro Channel loading. Also, the larger the system, the more time it takes to get
around the network. In this case, the probability increases that the timeout will
be reached.
Later in this section we will discuss how to diagnose this kind of problem by
analyzing the switch log files.
108
SP PD Guide
This soft copy for use by IBM employees only.
Notice that in the SP Switch, the Estart_sw calculates the timeout based on the
number of switches:
LIMIT = 180 + ((NUM_SWITCH - 2) * 60)
where NUM_SWITCH > 2
The following steps are referred to as Switch Initialization :
1. An Estart is issued for a system partition from the Control Workstation,
through either SMIT or the command line, and this is relayed to the primary
node of the partition as an Estart_sw .
2. The primary node consults the SDR for the current topology file and the
current fenced nodes.
3. The primary node distributes the topology file as appropriate:
•
The primary node distributes the topology file to the bootserver nodes of
its partition.
•
The primary node directs each bootserver to distribute the topology file
to its client nodes.
•
Each bootserver distributes the topology file, tests for success, and
returns resulting status to the primary.
•
The primary node logs and evaluates failure data.
4. The primary runs the Worm code to verify the partition′ s fabric pool and
nodes:
•
Each chip is sent a Read Status service package to check cabling.
•
Each chip is sent an Initialization service package to set the chip ID and
specify routes to the primary.
•
Each non-primary unfenced node is sent an Initialization service package
to set its personality and specify the topology file for this partition.
•
Each non-primary unfenced node is sent a Read Status node service
package to verify the switch address, personality, and readiness.
•
The primary node updates its device database in accordance with the
findings.
5. The primary node sets the Time-of-Day (TOD) across the fabric pool:
•
Traffic is quiesced, if necessary.
•
The TOD is propagated.
•
Traffic is resumed, if necessary.
6. The primary node downloads its route table to its TB3 adapter
7. The primary node distributes device database deltas to the nodes over the
switch through the Device Database service package
8. On each non-primary, unfenced node:
•
The local device database is updated with the deltas.
•
Routes are computed.
•
The routes are loaded to TB3 SRAM.
9. On each node, the communications protocols and Load Leveler code, as
appropriate, are notified that the switch is available.
Chapter 4. The Switch
109
This soft copy for use by IBM employees only.
10. The primary node updates the SDR switch_responds class for its partition.
For each node in the partition, the ( autojoin,isolated )-pair is set to one of the
following:
(0,0)
Initial
(0,1)
Fenced
(1,0)
On
(1,1)
Suspended
4.6 Reviewing Switch Processes
Figure 53. The High Performance Switch Board
fault_service_Worm_RTG
The Worm daemon is central to the functioning of the switch. It can be viewed
as having two main personalities:
•
Primary Worm
•
Secondary Worm
There is a third personality with the SP Switch:
•
Primary backup Worm
The primary Worm has a key role to play in the coordination of the switch
network. It is responsible for generating and updating the route tables through
the Route Table Generator(RTG), and for handling and recovering from switch
faults generated on the network. Switch faults are generated for a number of
reasons. For example, corrupted data packets, hardware faults, and running
110
SP PD Guide
This soft copy for use by IBM employees only.
Estart can all create a switch fault. Either the Worm on the nodes or the switch
chips themselves can report a fault to the Worm on the primary node.
The Worm process verifies the switch connections beginning at a node
designated as the primary node. By default, the primary node is node 1 in frame
1. You can override the default and designate another node as the primary
node. With the High Performance Switch, this must be done manually if the
primary is not operational, and the Estart command should then be run.
fs_monitor
This daemon monitors the adapter for interrupts that have not been serviced.
To check that both daemons are running on a node run:
# ps -ef | grep css
Note: Add “_SP” to each name to find out the SP Switch daemons.
4.6.1 Switch Responds
The spmon GUI for switch_responds has changed for the SP Switch. Figure 54
shows the differences between them:
initial state
on the switch
fenced (no autojoin)
fenced with autojoin
failure
High Performance Switch
SP Switch
red
green
yellow
yellow
yellow
green
red
yellow
red
Figure 54. Switch Responds
For the SP Switch, an extra attribute has been added to the SDR object class
switch_responds called adapter_config_status which gives the results of the
switch adapter′s configuration method. This field is left blank for the High
Performance Switch adapters only if you do not have PTF 11 installed. Here are
the possible values for this attribute for the SP Switch at the present time:
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
not_configured (initial value)
css_ready
(method was successful)
odm_fail
chkslot_fail
busresolv_fail
getslot_fail
xilinit_system_fail
xilinit_load_fail
dd_load_fail
genmajor_fail
genminor_fail
make_special_fail
build_dds_fail
dd_config_fail
diag_fail
fs_load_fail
fs_init_fail
Chapter 4. The Switch
111
This soft copy for use by IBM employees only.
If a node does not come up on the SP Switch, always check this attribute using
the following command:
# SDRGetObjects switch_responds adapter_config_status
This may give a good indication of where the problems lie. To assist with the
understanding of these attributes, here is a list that summarizes the
configuration of the TB3 switch adapter for the SP Switch (cfgtb3):
1. Checks the ODM database for the css device (odm_fail).
2. Loads the xilinx microcode for the adapter (xilinx_system_fail and
xilinx_load_fail).
•
There are distinct xilinx loads for the 2 types of adapter
− tb2_xilinx_file
− tb3_xilinx_file
3. Loads the device driver (dd_load_fail).
•
There are distinct drivers for the depending on the type of adapter
− cssdd2
− cssdd3
4. If the special device file /dev/css0 does not exist, then it creates it
(genmajor_fail, genminor_fail and make_special_fail).
5. Calls the device driver to configure the device (build_dds_fail and
dd_config_fail).
6. Marks the device css0 as available.
7. Executes POST diagnostics with the different routines depending on the type
of adapter (diag_fail).
8. Loads and initializes the CSS kernel extension which provides support for
fault service and DMA (fs_load_fail and fs_init_fail).
9. Sets switch_responds attribute adapter_config_status to css_ready in the SDR
(for TB3 only).
The three attribute values not explained so far are:
•
•
•
chkslot_fail
busresolv_fail
getslot_fail
After the check is made to test whether the ODM attributes are present for the
adapter, some tests are carried out on the bus to detect which slot the adapter is
in.
From the value in this object class, it is possible to find out the area in which the
failure occurred. This is a major diagnostic benefit for the TB3 adapter.
For completeness, here is the unconfigure method (ucfgtb3):
1. Performs the ODM check for the TB3
2. Disables the TB3 adapter
3. Unloads the CSS kernel extension
4. Kills the CSS daemons
5. Unloads the TB3 device driver
112
SP PD Guide
This soft copy for use by IBM employees only.
6. Marks the device css0 as defined
There is an undocumented command called css_restart_node that runs first the
unconfigure method and then the configure method. This command should only
be run at the request of an IBM engineer as the results can be unpredictable in
certain circumstances.
4.7 Switch Log Files
There are numerous log files associated with the switch, some of which can
provide essential data for resolving switch problems. It is impossible in this
redbook to provide enough information about how to read and interpret these
files. Instead, a brief example is given of what type of data is contained in these
files, along with an example of some typical output. It is not expected that the
reader will be able to resolve all the problems by using these logs, but that the
first level of analysis can be undertaken in most cases prior to contacting the
local IBM Support Center. A utility is provided called css.snap which will create
a compressed tar image of all the switch logs in the following format:
/var/adm/SPlogs/css/<hostname>.<date>.css.snap.Z
Run the command:
# dsh -a /usr/lpp/ssp/css/css.snap
Then transfer all the compressed tar images to a single system such as the
Control Workstation to provide the data to the local IBM Support Center.
/var/adm/SPlogs is a specific directory for SP logs. In this directory you will find
the following files:
On the Control Workstation:
•
•
•
•
/var/adm/SPlogs/css/Eclock.log
/var/adm/SPlogs/css/Ecommands.log
/var/adm/SPlogs/sdr/SDR_config.log
/var/adm/SPlogs/sdr/sdrlog.<cws-ip-address>.<PID>
On the Primary Node:
•
•
•
•
•
•
•
•
•
•
•
/var/adm/SPlogs/css/rc.switch.log
/var/adm/SPlogs/css/out.top
/var/adm/SPlogs/css/fs_daemon_print.file
/var/adm/SPlogs/css/flt
/var/adm/SPlogs/css/dtbx.trace
/var/adm/SPlogs/css/dtbx_trace.failed
/var/adm/SPlogs/css/daemon.stderr
/var/adm/SPlogs/css/daemon.stdout
/var/adm/SPlogs/css/cable_miswire
/var/adm/SPlogs/css/router.log
/spdata/sys1/logtables/css.tab
On a Node:
•
•
•
•
•
/var/adm/SPlogs/css/rc.switch.log
/var/adm/SPlogs/css/dtbx.trace
/var/adm/SPlogs/css/flt
/var/adm/SPlogs/css/fs_daemon_print.file
/var/adm/SPlogs/css/daemon.stderr
Chapter 4. The Switch
113
This soft copy for use by IBM employees only.
•
•
/var/adm/SPlogs/css/daemon.stdout
/spdata/sys1/logtables/css.tab
rc.switch.log
The log file contains specific information about the node that relates to
the switch. If you do not know what kind of switch type is installed at the
SP System, look at this log file. The information is retrieved from the
ODM. The rc.switch script configures the Switch adapter css0 by issuing
an ifconfig command. Any error relating to the ifconfig command will
also appear in this log file.
This file is updated/created when rc.switch has been executed. Usually
it is run from /etc/inittab at boot time. The rc.switch script starts the
fault_service_Worm daemon as well as the fs_monitor daemon.
out.top
This file will show problems that arise during switch initialization ( Estart ).
A copy of the out.top file of a previous run will be called out.top.old.
Both files will only be found on the primary node. It is like a copy of the
topology file.
Example:
Exx-Nxx -17 R: link to device is replaced by wrap plug or cable
This error usually indicates that this is an empty slot in the frame caused
either by having an installed wide node or a partially filled frame. The -R
indicates that the error was on the right hand side of the link, which in
this example is the node or switch adapter side rather than the switch
chip port side.
When Estart finds problems with the SP Switch, they are reported next to
the switch connection that has the problem. Most of the error messages
are documented in the Messages and Diagnosis Guide.
If Estart fails to initialize any of the nodes, go to this file and see whether
there are any error messages which could indicate the cause of failure.
If there is an unusual pattern of errors where it reports wrap plugs where
they should not be, it could be that there are problems with the
configuration. Go back and verify that the data is all correct and
consistent.
fs_daemon_print.file
This log file is a detailed account of the fault_service_Worm_RTG
daemon.
If the Worm keeps dying, look into this file to attempt to find an indication
of why this is happening.
flt
This log is a cumulative record of switch faults, including those
generated by an Estart. Normal usage of the switch may cause
occasional faults. This file is not only an error log.
An indication of an adapter problem may be multiple occurrences of
switch faults for the same node, which would show up in this file. An
indication of a switch chip problem will also be shown with multiple
switch faults in this file.
114
SP PD Guide
This soft copy for use by IBM employees only.
The format of this file is considerably different between the SP Switch
and the High Performance Switch. This in part reflects the difference
between the two switches in the way they detect and handle switch
faults.
dtbx.trace
This provides traces from switch diagnostics.
dtbx_failed.trace
This is created if any of the switch diagnostics fail. It is basically the
same as the dtbx.trace file, with the addition of error messages. If the
diagnostics run clean, this file will not be created.
daemon.stderr
General error messages. For example, if some nodes could not get
initialized when the Estart was issued, you may see the following:
Processing Estart. The following node(s) could not be initialized:
sp21n03
In this case the node in question (sp21n03) was not initialized because its
Worm daemon was not running.
daemon.stdout
This log is a detailed account of the switch initialization process. Most
switch problems do not require analysis. However, in some
circumstances it may prove useful to diagnose the problem.
There are also many normal, informational switch messages that you will
see in the error report. For instance, when you issue an Estart, you will
see a switch fault in the error report.
Expect one of each of these messages for each Estart command:
ERROR_ID TIMESTAMP T CL Res Name
34FFBE83 0502140496 T H Worm
C3189234 0502135796 T H Worm
ERROR_Description
HPS Fault - detected by switch chip
HPS Fault - not isolated
In addition to these log files, there is always a possibility that errors will be
recorded in the error report ( errpt ). It is important to note the time of the failure
in order to correlate messages in the error report errpt to the error.
For many problems, looking in the log files does not provide sufficient
information to solve the problem.
In the directory /usr/lpp/ssp/css, there are a few helpful tools, such as:
css_dump
This will format trace entries relating to the cssdd. To run the command,
issue css_dump > /tmp/css_dump.out &. You will find the most recent
entries at the bottom of the output file. This information is helpful in
conditions where the css driver code hangs for unknown reasons. This
command should be run on the primary node and on any of the failing
nodes.
Chapter 4. The Switch
115
This soft copy for use by IBM employees only.
fs_dump
This will format fault_service kernel extension traces. This command
should be run on the primary node and any of the failing nodes. To run
the command issue fs_dump > /tmp/fs_dump.out &.
4.7.1 The out.top Log File
The following is an example of out.top file output:
s 14 2 tb0 9 0
E01-S17-BH-J32 to Exx-Nxx
s 14 2 tb0 9 0
E01-S17-BH-J32 to Exx-Nxx -4 R: device has
been removed from network - faulty (wrap plug is installed)
The out.top log file is broken into a logical and physical notation. There are also
comments in the file that are designed to help you understand the basic
connections that are occurring. These comments are preceded by the pound
sign (#). The comments at the top of the file should help you to remember the
format. Other comments describe a group of connections (such as nodes
connected to board 1). These comments precede the connections which they
describe.
After the logical and physical nomenclature is given on a line, the fault
information is given with an error number, an indication of which side of the
connection found the error, and a description of the error: -4 R: device has been
removed from network - faulty (wrap plug is installed) means there is a wrap
plug where an adapter was expected, usually because the previous was a wide
node.
out.top messages
1. -1 Indicates that a switch resource is uninitialized. It says that the
initialization code never even got far enough in the network to attempt to
initialize the resource. Something was broken downstream from it that
prevented the code from getting to it. Traditionally this has only been done
for nodes. However, this should change in the future. This is quite often an
indicator of some sort of clock problem.
2. -1, -3, -4 are faulty link indicators. When these are reported on single ports,
they can indicate problems with a cable or a port that will lead to FRU calls.
It can also indicate a powered-off node or switch. Patterns of these can also
indicate other problems with clocks and power.
3. -5 is rare message that indicates you should look for the cable_miswire file
on the primary node.
4. -6 indicates some kind of problem with an adapter. This would be an
unusual occurrence.
5. -7 indicates that for some reason the fault service daemon on the node could
not respond back to the primary within the time limits. This quite often
means that the daemon was killed or never started. The rc.switch.log or
fs_daemon_print.file log files on the node can give you indications as to why
this happened. There is a rarer condition in which the node is so busy that
the daemon does not have time to respond. (This was more prevalent in
SP1 days.)
116
SP PD Guide
This soft copy for use by IBM employees only.
6. -8 is the most common indicator of a miswire. You should look for a
cable_miswire file on the primary node.
7. -9 could mean that the switch element (chip or adapter) was failing.
8. -10 through -15 are indicators that something failed during testing or a switch
chip′s RAM. The switch board on which it resides is the FRU.
9. -16 usually indicates some sort of clock setup problem. This is most often
reported on the nodes. For some reason the switch chips are usually
reported with a -2, -3, or -4 when they have clock problems. If you see it on
a node, what usually has happened is that the node was powered-on before
the switch had its clock set up to the correct clock. In the case of a single
switch system, the node was powered-on before the switch. There was also
an old bug where the power-on diagnostics selected the wrong clock on
which to run: a gore clock instead of a data cable clock when attached to an
HiPS 3.0, or a data cable clock instead of a gore clock when attached to an
HiPS 2.0.
10. -17 is more of a warning than an error. Make sure that it makes sense that
there is a wrap plug on that port. It makes sense when the node is not
populated or when the cable has been removed for some reason.
11. -18 is similar to -17, but occurs much more rarely.
12. -19 is very similar to -7 and was introduced later in the program when we
began distributing routes across the switch. The fault service daemon on the
receiving node must have time to service the route table information.
13. -20 is similar to -8, but is rarely seen.
14. -21 and -22 are very strange and have never been seen. Call for help!
15. -23 will be seen more often when more nodes are fenced in a system.
16. -24 should never occur. If you see it, call for help.
This file is very useful, because this is a dump of the topology file with some
comments about errors found when the switch was initialized. Looking at this
file, you can find at a glance some common wiring and node down problems.
4.7.2 Patterns in out.top File
1. Uninitialized = -1
- > look for pattern
2. Link errors = -2, -3, -4 - > look for pattern
3. Miswires = -5, -8, -20
- > check cable_miswire
4. Node time-outs = -7, -19 - > look for pattern
5. Unusual which imply FRU immediately = -6, -9 through -15 - > replace FRU
6. Clock = -16 - > look for pattern
7. Warnings = -17, -18, -23 - > verify the statement it makes is expected
8. Call for help = -21, -22, -24 - > call
Categories that require pattern recognition: 1, 2, 4, and 6.
Patterns:
1. An internal port (ports 5, 6, 7, 8) is reporting problem
Chapter 4. The Switch
117
This soft copy for use by IBM employees only.
For the most part, if an internal port reports an error, the FRU is the card
that contains that port. You may discern patterns that indicate clock
problems, but you will quickly deduce that the FRU is the same because the
clock problem is a broken driver on the switch card.
2. All board patterns
There should be very few errors that occur on the whole board, because
once you get enough errors, you cannot get to the other parts of the board to
see if they are in error.
3. Half board pattern
When you see a half board with a problem, check to see if it matches the
clock tree. The majority of these patterns of error are clock-related.
4. All the nodes are reporting a problem
If all of the nodes are reporting an error, it is usually a -1, -7, -16, or -19.
These quite often point to clock problems, or power sequence problems,
which result from nodes being on the incorrect clock.
A -1 on all of the nodes on a board will occur on boards that are not on the
same board with the primary node: the primary node throws this off, because
if you have gotten as far as generating an out.top file, the primary node is
operational and reachable.
With a -1 on all the nodes, you will probably see -2, -3, or -4 on the ports that
connect to other switches. What this indicates is that the failing switch board
is not on the same clock as the primary node′s switch board. This can
happen because:
a. The clock tree was not set up properly by issuing an Eclock with the
correct Eclock topology file.
b. The clock to this board is broken in this switch assembly, in the cable, or
in the switch that sources this board′s clock.
c. If the primary node′ s board is the only one that is tunable, it may be set
to the incorrect clock.
A -16 can indicate a poor power-on sequence. For example, if the nodes in a
frame are powered-on before the switch, all the adapters will be set to their
internal clock (on card oscillator). You can discover this by looking in the
dtbx.trace file. Another example is that the switch was powered on before
the nodes, but the clock was not properly set. When the proper clock is
selected, the clock is momentarily interrupted, which causes the adapter to
have problems.
-7 and -19 both point to daemon time-out problems. The -7 occurs when the
primary node has initialized a node′s adapter and is waiting for that node′ s
daemon to respond to communication that asks what node it thinks it is. The
-19 occurs after the whole switch has been tuned and the route table is being
distributed to the nodes. In this case, the daemon on the receiving node is
not responding. These -7 and -19 errors can occur more easily in large
systems than in small systems, because large networks will naturally eat
more into the time-out period during normal operation than a small network
will.
5. All of the switch-to-switch connections are reporting a problem
This is quite often a clock or power problem. It can be on the board, the
clock card, the clock source cable, the power card, or the power cable.
118
SP PD Guide
This soft copy for use by IBM employees only.
6. All the ports on a chip are reporting a problem
If all of the ports on a chip are reporting a problem, and they are not all
connected to the same switch board, it is most likely a problem with the
chip. If they are connected to the same switch board, you will probably
discover that all of the ports connected to that other switch have problems.
7. A single port is reporting a problem
When a single port finds a problem, the maintenance manual is usually quite
adequate in making the call.
The error to watch out for in a single port pattern is the one where the
primary node cannot get into the switch. This can point to a power sequence
or clock problem on the primary node. Check the diagnostics file at
/var/adm/SPlogs/css/dtbx.trace. You may find that it is on an incorrect
clock. Of course, it could still be the adapter, the cable, or the switch port to
which the primary node′s adapter is connected.
4.7.3 The flt Log File
Important
This section and the following sections on the flt file apply only to the High
Performance Switch.
Faults are not as important or critical for the SP Switch as they are for the
HiPS switch, so the flt file has changed with the new switch, and it is no
longer an important diagnostic tool.
It is very important to note that the flt file is not a diagnosis of the problem. It
tells you which device saw the problem . The problem could be with that device,
or it could be with the device to which it is connected.
What you are looking for in the flt file is a pattern of errors over time. One error
in the flt file does not imply a problem. In fact, there is a finite probability that a
fault will occur. What you are looking for is a device that continually faults, say
every day, or whenever a certain application runs, or in some other consistent
fashion.
When looking for patterns, you should realize that the flt file records all
information that the fault daemon on the primary node collects from the switch.
This includes nodes being powered off for service, or whenever someone runs
Estart. You need to recognize such events so that you discard them from your
pattern recognition.
•
Estart is likely to have occurred when you see a VDC_FLT=0000 or 0080,
and there is a report like this: No fault isolated, VSP VDC_FLT=0000.
•
You must also be able to note when it is likely that a node was powered-off
or a cable was pulled. If you see a fault reported when you know a node
was powered-off, you should ignore it. If you see a fault that indicates a
node might be causing the fault, you should check out the time stamp and
see if the node was powered-off around that time.
•
If you know that the system was in a state of turmoil during a certain period
of time, you should suspect that faults during that time are to be expected.
During such periods of turmoil, it is often the practice of system
Chapter 4. The Switch
119
This soft copy for use by IBM employees only.
administrators to power things off and on. Such events will cause switch
faults.
•
If many devices report errors at the same time, it is very possible that there
is something strange going on. You should delve back into your knowledge
of how the clocks are distributed and how the boards are connected before
you determine if this is a real problem or not. You could be seeing power
glitches, clock glitches or some sort of non-hardware related problem. For
example, there is/was a problem with heavy Micro Channel loading on the
primary node. In systems that are AIX 4.1 and beyond which have node
isolation (switch fence/unfence) capabilities, the switch goes into service
phase every 2 minutes to see if it needs to fence or unfence a node. If the
daemon cannot get processor time on the CPU, usually because of heavy
Micro Channel use, it will leave the switch in the service phase for too long,
and a time-out will occur. This will cause massive faulting in the switch.
•
If many ports on a switch chip report an error, there is probably something
strange occurring with the clocks, the power, or again some sort of other bug
like the one for fence/unfence.
•
If an on board port (port 4 through 7) is called, the FRU is the switch
assembly that houses the chip that is reporting the fault.
•
If an adapter reports a fault and it has an MSTAT of 12345678, this is a bogus
error. The software knows that it has done something that might cause an
error to be reported; therefore, when it sees it, it flags that error as bogus by
setting the MSTAT to 12345678.
•
Link errors detected by adapters will have an MSTAT of 000000c0. This is
because bit 6 of the MSTAT is the bit that indicates a link error has been
detected.
•
If an adapter reports a fault and it has an MSTAT of 00000080, you know that
the error was found on the node side of the adapter. If this is accompanied
by a VDC_FLT=1000, you should check the error log to see if a CRC error
occurred. Basically, VDC_FLT=1000 and MSTAT=00000080 indicates that
the software/microcode has found an error that it deems serious enough to
cause the switch to fault. Quite often this is because of a CRC error, but
there are other possibilities.
•
If VDC_FLT is not 1000 and you get an MSTAT of 00000080, it is quite possible
that the adapter or the IO planar have a problem; you should run
diagnostics.
•
If an adapter reports a valid link fault, you should run diagnostics.
4.7.4 Reading the flt File
Figure 55 on page 121 shows the flt file, which is discussed in the following
sections.
120
SP PD Guide
This soft copy for use by IBM employees only.
Figure 55. The flt File
The flt file has some nomenclature that differentiates device types, but it also
lists the device number in a field that is generically labeled “id.” With this in
mind, it was decided to differentiate switch IDs from nodes IDs by adding 100,000
to them. In this way, you cannot confuse a node with a switch, unless you have
more that 10,000 nodes in your system. Why 10,000 nodes? The last digit of the
switch ID tells you the chip on that switch. So, you are actually adding 10,000 to
the switch board number. This leaves 10,000 node IDs before you hit the first
switch ID at 100,000.
Note
•
•
Therefore if the ID is < 100,000 you know that it is an adapter.
If the ID > 100,000 you know it is a switch.
You can translate the flt notation to out.top notation so that you can look in the
out.top file to determine the physical location of the connection.
The important information in the flt file is:
•
The device ID, which tells you which device reported seeing the fault.
•
For switch chips IDs, the WHY registers information. This is really important
to determine master/slave miscompares and which port is reporting the
problem. The actual error type in the WHY is of lesser importance. If the
chip can narrow down the information to a port, it will report WHY xx TO xx
TE xx DO xx RF xx FC xx DE xx, where TO, TE, DO, RF, FC, and DE are
registers for each different error category underneath that particular WHY
code. The register value, xx, indicates which port saw that error. Each bit
stands for a port. Port 0 is the least significant bit, and port 7 is the most
significant bit. If a particular error, such as TO, was not seen, then its
register value will be 00. If a TE was found on port 2, the value will be 04,
Chapter 4. The Switch
121
This soft copy for use by IBM employees only.
because port 2 corresponds to bit 2. If a DO was found on port 5, the value
will be 20, because port 5 corresponds to bit 5. If you are unfamiliar with
such notation, you may find it useful to translate the hexadecimal values to
binary first. Then you can find which bit is on and find the corresponding
port that matches it: simply count from right to left, starting at 0.
•
It is not important to recognize whether the error was a TO, a TE, a DO, so
on. This information is left in for historical reasons and may be useful to
development, but not to making a FRU call.
•
For adapters, indicated as VDC, id X, the VDC_FLT and MSTAT are important
pieces of information.
Master/Slave Miscompare (Only HiPS)
Knowing whether a master/slave miscompare has occurred between a switch
chip pair is critical in making a FRU call on faults reported by switch chips.
Recall that each switch chip function is actually performed by two physical chips.
Both chips are taking input from the rest of the system. The master chip is
providing the outputs to the rest of the system. The slave chip is using the
inputs from the rest of the system and checking the outputs from the master to
see if they make sense. When they do not make sense, an error is flagged.
Although this is an expensive way of checking for errors, it is quite thorough,
because in order to let an error escape, both chips would have to break in the
same way at the same time.
In the flt file, the master is noted as “chip 0” and the slave is “chip 1.” For
example, Switch, id 10036, chip 0 time = 006ef91f5a65 is a report from master
chip 10036, while Switch, id 10036, chip 0 & 1 time=006ef91fa65 indicates that
both the master and slave chip saw the same thing.
If the master and slave report different errors, then this is known as a
master/slave miscompare . This indicates that they each saw something different.
If a particular port is reported in error, by either the master or slave, then there
is a good chance that the problem is either with the board or the cable. The
cable may be the problem, because it may be attenuating the signal such that it
reaches a voltage in no-man′s land and one may decide it is a zero and the
other may decide that it is a one, and there is your master/slave miscompare.
If the chips cannot narrow things down to a port, the odds increase that the
problem is with either the master or slave switch chip.
If the master and slave report the same error, then it is more likely that the
problem is on the other side of the link/cable, or it is the cable.
If the port called is not on board (port 0 through 3), you should always check the
cable and connectors for bent pins.
If an onboard port (port 4 through 7) is called, the FRU is the switch assembly
that houses the chip that is reporting the fault.
122
SP PD Guide
This soft copy for use by IBM employees only.
4.7.5 Fault Syndrome on the flt File
The fault syndrome register is the register that collects error information in the
adapter. There are two classes of error with which we should be concerned:
•
VDC errors occur on the link. There are bits 0, 4 through 11 and 13. These
could be the adapter, the cable, or the switch port to which the adapter is
connected. Bit 8 can also be forced by software/microcode when it finds a
problem that it feels may cause a switch fault. True VDC errors are
indicated by an MSTAT equal to 000000c0.
•
Adapter/node errors are indicated by the other bits. These indicate either a
problem with the adapter or the node.
In all cases, diagnostics should be run.
Figure 56. Fault Syndrome on flt File
MSMU Status Register
The MSMU status register is almost always:
•
00000080 - which is normal
•
000000c0 - which indicates a link error
•
12345678 - which indicates that software expected a fault and the information
in the fault record is to be ignored.
Any other status reported probably means that the adapter has a problem. Run
diagnostics.
Chapter 4. The Switch
123
This soft copy for use by IBM employees only.
4.8 Additional Problem Determination
The following sections discuss determining additional system problems.
4.8.1 Debugging Scripts
If a problem could not be determined by the log files, it is useful to debug the
command which fails by itself. Several commands used for SP Switchs are shell
scripts or perl scripts.
Shell scripts could be debugged by inserting set -x in the beginning of a script.
It should be inserted in a new line right after #!/bin/ksh.
Perl scripts could be debugged by inserting -d flag just in the first line of the
script.
#!/usr/lpp/ssp/perl/bin/perl -d
•
Run the commands:
# script <filename>
# <name of perl script>
−
From within the perl script enter:
-
−
″t″ (to turn trace on)
″c″ (to continue)
Then run:
# exit
(to stop the script command)
4.8.2 AIX Error Logging
In addition to the log files, there is always a possibility of errors being recorded
in the error log (/var/adm/ras/errlog). These errors can be read by using the
error report command errpt. It is important to note the time of the failure in
order to correlate messages in error report errpt to the error. There are also
many normal, informational switch messages that you will see in the error
report. For instance, when you issue an Estart, you will see a switch fault in the
error report.
Expect one of each of these messages for each Estart command.
ERROR_ID TIMESTAMP T CL Res Name
34FFBE83 0502140496 T H Worm
C3189234 0502135796 T H Worm
ERROR_Description
HPS Fault - detected by switch chip
HPS Fault - not isolated
Figure 57. Message in Error Report while Estart Has Been Executed
To get some error reports specific to the switch, you can use dsh -a errpt -a -N
css or dsh -a errpt -a -N Worm. You can also run diags if you suspect a
hardware problem on the switch: diag -c -d css0 or diag -A -d css0.
124
SP PD Guide
This soft copy for use by IBM employees only.
Chapter 5. System Partitioning
This chapter describes System Partitioning in a way that will enable the reader
to understand how all the key components fit together, and give an
understanding of how to carry out problem determination based on this
information.
The way in which the RS/6000 SP can be partitioned is dependent on the
topology of the High Performance Switch, and so this is where the topic is
started after a brief introduction. Even in those instances where the High
Performance Switch is not installed, System Partitioning follows the topology of
what it would expect to see if a High Performance Switch was installed in each
frame. It is essential that the reader fully understands the information laid out in
the previous chapter on the High Performance Switch before beginning to read
the following details about System Partitioning.
5.1 Scope, Rules, and Limitations
It is important to understand which components are affected by System
Partitioning before carrying out any of the associated procedures. In this way
you can prevent many of the problems that you might otherwise encounter.
In addition, it may be of assistance in deciding whether System Partitioning is
suitable for the environment or what is the most suitable configuration to choose.
5.1.1 Scope of System Partitioning
The following components of the POWERparallel System Support Programs are
affected by System Partitioning:
•
High Performance Switch
•
The Heartbeat
•
System Data Repository (SDR)
•
Job Manager
These topics will be dealt with individually in far greater detail later in the
chapter, but it is worth noting that all these components maintain a completely
separate and non-interfering environment in each partition that you set up. The
reorganization of these subsystems is largely managed by the scripts that are
provided in POWERparallel System Support Programs Version 2.1 that can be
run from the SMIT screens for System Partitioning. You can use the following
SMIT fastpath, for example:
# smit syspar
Many components remain systemwide and are not affected by System
Partitioning. These components continue to be administered in exactly the same
manner both before and after setting up the partitions. Some examples are:
 Copyright IBM Corp. 1996
•
Kerberos
•
User Management
•
Accounting
125
This soft copy for use by IBM employees only.
5.1.2 Some Rules for Partitioning
There are some basic rules that should always be followed when you set up the
partitions which impose some limitations on the configurations that can be
selected for the partitions.
All nodes on a switch chip must be in the same partition. The previous chapter
outlines which switch chips service which nodes. From this, it can be seen that
in a single frame, single switch system, with two wide nodes in slots one and
three, it would not be possible to have these two nodes in a partition on their
own. Later in the chapter we will look at some further configurations in more
detail.
In a POWERparallel System Support Programs Version 2.1 system where you
have not explicitly set up System Partitioning, you still have a single, default,
partition. Many of the configuration files and variables are in place; it is just that
they always point to the only partition that exists.
Within a partition, it is essential to have all the nodes installed with the same
version of AIX and POWERparallel System Support Programs. If by some chance
there are mixed versions within a partition, then many components will fail to
work properly (if at all), inconsistencies will appear in some of your output, and
the configuration will not be supported. In this case, these nodes should be
reinstalled at the correct level to ensure consistency throughout the partition.
Check the versions of products installed, using either the lslpp command or the
oslevel command. For example, the following command can be run to check the
version of POWERparallel System Support Programs:
# lslpp -l | grep ssp
If there is a requirement to have more than a single AIX Version 3.2.5 partition,
then ensure that a recent level of maintenance is applied. Check the level by
issuing the following command:
# lslpp -L | grep ssp.basic
Here is an example of the output from this command:
ssp.basic
2.1.0.10
C
SP System Support Package
To provide the support for multiple AIX Version 3.2.5 partitions, ensure that the
level of ssp.basic is at least 2.1.0.8. An AIX Version 3.2.5 partition is always the
default partition, but this topic will be addressed in more detail later on.
The Control Workstation must be at AIX Version 4.1 and PSSP 2.1 to provide the
support for System Partitioning. All the additional High Performance Switch
topology files required for the many partitioning configurations are supplied in
the product ssp.top . Ensure this product is installed on the Control Workstation
before beginning any tasks associated with System Partitioning.
When the Control Workstation is installed at PSSP 2.1 and AIX Version 4.1, it is
only able to act as an install server for nodes at the same version of code. It is
not possible to install PSSP 1.2 and AIX Version 3.2.5 nodes from this Control
Workstation. It is essential, therefore, to create at least two boot/install servers
on the AIX Version 3.2.5 nodes prior to upgrading your Control Workstation to
AIX Version 4.1. More details on how to do this are in Chapter 2, “The
Installation Process” on page 7.
The reason that at least two boot/install servers are needed is so that if one of
the boot/install servers needs installing, there is another node from which to
126
SP PD Guide
This soft copy for use by IBM employees only.
carry out this task. The underlying reason behind this is that PSSP 2.1 uses a
product called the Network Installation Manager (NIM) to carry out many of the
tasks associated with the installation of the nodes. NIM is not compatible with
AIX Version 3.2.5.
While creating partitions with different versions of AIX, be extremely careful
when rebooting the nodes after applying the System Partitioning, and ensure that
the desired action has taken place. If the node should network install, then
check that this has actually happened. Similarly, if the node should be rebooting
from disk to the same version of AIX, then ensure this also actually happened. If
any discrepancies are found, then attempt to rectify the situation immediately.
5.1.3 Some Limitations of System Partitioning
Before beginning System Partitioning, it is a good idea to assess whether the
following limitations will have an effect on the configurations that can be applied:
•
Shared hard disk drives must be connected to nodes in the same partition.
•
HACMP (Highly Available Clustered Multi Processors) nodes must be in the
same partition.
•
Virtual Shared Disks (VSDs) cannot span partitions.
If there are different versions of AIX in the partitions, then it is obvious to see
how the issue of compatibility of code makes these limitations essential. Even
when all the partitions are running the same versions of code, there is still good
justification for these limitations.
Typically, System Partitioning is set up to logically separate applications (for
example, to separate applications or company departments). In these instances,
there would be little sense in having a node take over the resources of another
node in a different partition using HACMP.
Similarly, there would be little point in spreading a database across two
partitions using VSDs, when the partitions service completely different
departments that do not use the same database tables. If these two
departments did use the same database tables, then the database must reside
within one partition when using VSDs.
5.2 Partitioning and the High Performance Switch
The High Performance Switch is central to the configuration of System
Partitioning. Even in systems that do not have a High Performance Switch
installed, the configuration is still based on the assumption that a switch is
installed in each frame. In other words, similar sets of rules apply to configuring
the System Partitioning, regardless of whether a High Performance Switch is
installed or not. In fact, the only difference is for systems that have a High
Performance Switch that services nodes in more than one frame, but this issue
will be addressed in more detail later in this chapter.
Chapter 5. System Partitioning
127
This soft copy for use by IBM employees only.
5.2.1 Partitioning a Single Switch/Frame System
Figure 59 on page 131 shows a single switch board and the four switch chips
that service the nodes. On the basis that all nodes on a single switch chip must
be in the same partition, the maximum number of partitions that are possible is
four. The minimum number is the default of one. All combinations in between
are also supported, as shown below:
Nodes
Description
16
The default of a single partition of all 16 nodes
4_12
4 nodes in one partition and 12 nodes in another
4_4_8
2 partitions of 4 nodes and one of 8 nodes
4_4_4_4
4 partitions of 4 nodes
8_8
2 partitions of 8 nodes
For the 16 and 4_4_4_4 configurations, there is only one possible layout for each
one. However, for the other configurations it is possible to choose from different
layouts, grouping different combinations of nodes in different partitions while still
observing the rule that all nodes on a switch chip must be in the same partition.
Taking the example of the 4_12 configuration, there are 4 possible layouts. The 4
node partition can consist of the following node combinations (with all the other
nodes in the 12 node partition):
Nodes
Nodes
Nodes
Nodes
1, 2, 5, and 6
3, 4, 7, and 8
9, 10, 13, and 14
11, 12, 15, and 16
This is based on the assumption that all of these are thin nodes. The reality is
often that you have a combination of thin and wide nodes, and that the frame
may have empty slots. The same rules apply though, and you should consider
these groupings as node slots rather than actual nodes. Here is an example of
applying a 4_12 configuration where there are 2 wide nodes occupying the
bottom 2 drawers, there are 10 thin nodes, the top drawer is empty, and the
layout for the 4 node partition is chosen to contain node slots 1, 2, 5, and 6:
4 partition
12 partition
Nodes 1, 5, and 6
Nodes 3, 7, 8, 9, 10, 11, 12, 13, and 14
The 4 partition does not contain node 2 because this slot is occupied by wide
node 1. Similarly, node 4 is absent from the 12 partition. Nodes 15 and 16 are
absent because these slots are empty since the top drawer of the frame is
unused at present. Therefore the reality is that the 4 partition contains 3 nodes
(1 wide, 2 thin) and the 12 partition contains 9 nodes (1 wide, 8 thin).
Even when using the notion of node slots rather than nodes, it is still not
possible to accurately represent the situation where you have a single switch
servicing more than one frame. This is still a single switch system and the same
rules apply that all configurations are supported, as just described, but a closer
look at the switch topology is required to assess which nodes will be in which
partition in each of the possible layouts.
The following example is based on having 1 switch board servicing 2 frames that
are both fully populated with 8 wide nodes. There are a maximum of 16 node
connections on a switch board, and in this example they are all utilized.
128
SP PD Guide
This soft copy for use by IBM employees only.
Following is an insert from the switch topology file for this configuration that
shows how the nodes are connected to the High Performance Switch:
#
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
s
Node connections in frame L01 to switch 1 in L01
15 3 tb0 0 0
L01-S00-BH-J18 to L01-N1
15 2 tb0 1 0
L01-S00-BH-J16 to L01-N3
16 0 tb0 2 0
L01-S00-BH-J20 to L01-N5
16 1 tb0 3 0
L01-S00-BH-J22 to L01-N7
15 1 tb0 4 0
L01-S00-BH-J14 to L01-N9
15 0 tb0 5 0
L01-S00-BH-J12 to L01-N11
16 2 tb0 6 0
L01-S00-BH-J24 to L01-N13
16 3 tb0 7 0
L01-S00-BH-J26 to L01-N15
14 3 tb0 8 0
L01-S00-BH-J10 to L01-N17
14 2 tb0 9 0
L01-S00-BH-J8 to L01-N19
17 0 tb0 10 0 L01-S00-BH-J28 to L01-N21
17 1 tb0 11 0 L01-S00-BH-J30 to L01-N23
14 1 tb0 12 0 L01-S00-BH-J6 to L01-N25
14 0 tb0 13 0 L01-S00-BH-J4 to L01-N27
17 2 tb0 14 0 L01-S00-BH-J32 to L01-N29
17 3 tb0 15 0 L01-S00-BH-J34 to L01-N31
Figure 58. Topology File Insert from a Single Switch 16 Wide Node System
Note that the node numbering does not follow the usual convention. For
example, where you would normally expect to see “L01-N2,” there is “L01-N3.”
The node numbering in relation to the slot numbers remains consistent, but the
physical cabling has changed to enable the connection of 16 wide nodes to the
same switch board. The J16 cable now goes to slot 3 (node 3) instead of slot 2
(node 2). This pattern continues up through the 2 frames.
This has an effect on how the nodes are allocated in the various layouts. Using
the 4_12 example again, here is one of the possible configurations:
4 partition
12 partition
Nodes 1, 3, 9, and 11
Nodes 5, 7, 13, 15, 17, 19, 21, 23, 25, 27, 29, and 31
Using the topology files in this way is the only accurate method that can be used
to assess the impact of System Partitioning on all possible RS/6000 SP
configurations. However, using the slot number method is perfectly valid for
configurations where a single switch services nodes in a single frame only.
If there was no High Performance Switch in this example of a 2 frame, 16 wide
node system, then the partitioning is done with the expectation that there would
be a High Performance Switch in each of the 2 frames, and so you would use the
slot number method to assess the impact of the various layouts on your
configuration.
Chapter 5. System Partitioning
129
This soft copy for use by IBM employees only.
5.2.2 Partitioning a Two Switch/Frame System
A maximum of two partitions only are supported in these configurations.
However, any combination is supported giving the following options:
Nodes
Description
32
The default single partition
4_28
4 nodes in one partition, 28 in the other
8_24
8 nodes in one partition, 24 in the other
12_20
12 nodes in one partition, 20 in the other
16_16
16 nodes in each partition
Within all except the 32 configuration, there are many layouts possible. For
example, in the 4_28 configuration, there are 8 possible layouts. As there are 8
switch chips servicing the nodes, it is possible to choose any one of these to be
in the 4 partition.
In the 16_16 configuration, it is possible to put each frame in a separate partition,
or half of each frame in each partition, or any other combination that falls within
the basic rules.
Even with the limitation of a maximum of two partitions, there are a large
number of permutations possible. This accounts for the large number of files
present in the ssp.top product and explains why these limitations were imposed
to prevent the product becoming enormous in size. It is possible to obtain
topology files that will support a configuration that is not shipped as standard in
ssp.top, by making a special request (RPQ) 2.
5.2.3 Partitioning a Three or More Switch/Frame System
In this configuration, a maximum of three partitions is allowed and all nodes
within a frame (or serviced by a single switch board) must be in the same
partition.
For example, in a four switch/frame system, the following are supported
configurations:
Nodes
Description
64
Default single partition system
16_48
1 frame in a single partition, 3 frames in the other
32_32
2 frames in each partition
16_16_32
2 partitions of 1 frame and another of 2 frames
Once again, there are many layouts for all but the default single partition.
2
Contact your IBM representative for further details.
130
SP PD Guide
This soft copy for use by IBM employees only.
5.2.4 Switch Topologies
The effect of partitioning the High Performance Switch is that there is no
interference between the partitions that have been set up. Anything that
happens in one partition will have no effect on the others. If a switch fault is
generated in one partition, this will not affect the switch in the others. The fabric
of the other partitions will remain stable while the Worm daemon on the primary
node in the partition that took the switch fault will attempt to recover the switch
network in that partition. This behavior is ensured by each partition having a
different topology file that does not contain any routes that would allow traffic to
flow between partitions. As a result, nodes in one partition have no knowledge
of how to communicate with the nodes outside its own partition. The Worm
daemon on the primary node is responsible for generating the routing tables,
which it then distributes to the switch adapters on the nodes for storing in their
NVRAM.
Each partition has its own primary node, so that running Estart in one partition
has no effect on the others. The Worm on the primary can carry out its tasks in
a completely independent manner from the other partitions.
Generating the correct routes for the partition based on the topology files that
get selected during the apply of the System Partitioning is critical to the health of
the switch in that partition.
Following is an example of how a single switch system with 16 thin nodes could
be partitioned using one of the layouts for the 8_8 configurations.
Figure 59. Example of an 8_8 Configuration
By deleting half of the routes (8 of the 16), there is no communication possible
between the two partitions. However, within the 8-way partition, there are only
two possible routes between each and every node (where previously there were
four). Halving the bandwidth in this way does have an impact on performance,
Chapter 5. System Partitioning
131
This soft copy for use by IBM employees only.
but not by 50%. Testing has shown that the expected performance reduction is
usually within the 10 to 15% range. Much will depend on the specifics of the
particular system, and the type of network traffic generated on the switch.
With the High Performance Switch, the IP protocol only uses one path at a time 3 ,
so the impact is likely to be less. There is still a scope of packet contention in a
busy switch network, because if a path is blocked, then only one alternative
exists. The user space message passing mode protocol is able to use multiple
paths, and so the performance impact may be greater depending on the type of
network traffic.
This protocol is used by parallel programs that require a high bandwidth and low
latency for their message passing. In addition, the impact of losing one of the
internal routes on the switch board becomes far more severe in the 8-way
partition, because only one path will be available for communicating between
nodes on different switch chips. The chance of experiencing packet contention is
increased considerably, which could have a major impact on performance. In an
unpartitioned system, the effect of losing an internal link or route would be
minimal and the switch could run indefinitely until an opportunity is available to
carry out maintenance.
Similar considerations can be applied to the 12-way partition, but the impact is
minimal because 3 out of the 4 routes are still available.
Based on the 8_8 example previously given, the topology files shown in
Figure 60 illustrate how the routes have been deleted.
# Node connections in frame L01 to switch 1 in L01
s 15 3 tb0 0 0
E01-S17-BH-J18 to E01-N1
s 15 2 tb0 1 0
E01-S17-BH-J16 to E01-N2
s 15 1 tb0 4 0
E01-S17-BH-J14 to E01-N5
s 15 0 tb0 5 0
E01-S17-BH-J12 to E01-N6
s 14 3 tb0 8 0
E01-S17-BH-J10 to E01-N9
s 14 2 tb0 9 0
E01-S17-BH-J8 to Exx-Nxx
s 14 1 tb0 12 0
E01-S17-BH-J6 to E01-N13
s 14 0 tb0 13 0
E01-S17-BH-J4 to Exx-Nxx
# On board connections between switch chips on switch 1 in Frame L01
s 14 7 s 13 4
E01-S17-SC
s 14 6 s 12 4
E01-S17-SC
s 15 7 s 13 5
E01-S17-SC
s 15 6 s 12 5
E01-S17-SC
Figure 60. Insert of Topology File for the First 8-Way Partition
Node connections are present only for the nodes in the partition, and there are
only 4 links present for the onboard switch chip connections. When diagnosing
configuration problems, check that the correct topology file is being used for the
partition you are having difficulty with. The topology files are stored in the SDR
directory:
/spdata/sys1/sdr/partitions/<IP alias address>/files
3
With the new SP Switch this is no longer the case; IP can use multiple paths.
132
SP PD Guide
This soft copy for use by IBM employees only.
IP address aliasing will be dealt with in detail later in the chapter, but it is
sufficient to know at this stage that each partition is identified by having a
different alias. The topology file for the second partition is shown in Figure 61
on page 133 for completeness.
# Node connections in frame L01 to switch 1 in L01
s 16 0 tb0 2 0
E01-S17-BH-J20 to E01-N3
s 16 1 tb0 3 0
E01-S17-BH-J22 to E01-N4
s 16 2 tb0 6 0
E01-S17-BH-J24 to E01-N7
s 16 3 tb0 7 0
E01-S17-BH-J26 to E01-N8
s 17 0 tb0 10 0
E01-S17-BH-J28 to E01-N11
s 17 1 tb0 11 0
E01-S17-BH-J30 to Exx-Nxx
s 17 2 tb0 14 0
E01-S17-BH-J32 to E01-N15
s 17 3 tb0 15 0
E01-S17-BH-J34 to Exx-Nxx
# On board connections between switch chips on switch 1 in Frame L01
s 16 5 s 11 6
E01-S17-SC
s 16 4 s 10 6
E01-S17-SC
s 17 5 s 11 7
E01-S17-SC
s 17 4 s 10 7
E01-S17-SC
Figure 61. Insert of Topology File for the Second Partition
This example is based on the Jack cable (Jxx) numbering system used on the
High Performance Switch, rather than on the newer SP Switch. The example is
based also on a system with eight thin nodes (1-8) and four thin nodes (nodes 9,
11, 13, and 15). The right side of the topology file shows “Nxx” to represent
where a wrap plug is inserted (rather than a Jack Cable that would normally be
present to connect to a node). In this case, the wrap plug is required due to a
wide node being present in that particular drawer.
There is another issue that should be considered in relation to performance
when setting up System Partitioning on a multi-switch system. Take an example
of a 5nsb.0isb configuration that is not currently partitioned. If you have a
resource pool of 20 nodes set up, for example, for running parallel jobs across
the switch, then the best placement of the nodes is likely to be with four nodes
on each switch to provide the greatest bandwidth possible. In this case, where
you are not using Intermediate Switch Boards (ISBs), there are only four cables
available to connect to each of the other switch boards, given that there are only
16 external Jack sockets available for external connections (rather than node
connections) and there are four other switches to connect to.
By placing the nodes evenly across the switches, each of the four nodes can
communicate with any of the other four nodes over four data cables. If you
placed ten nodes each on two switches only, then these ten nodes would only be
able to communicate over four cables to the other ten nodes and the bandwidth
is reduced considerably.
If a large amount of data is flowing across the switch during these parallel jobs,
then the chance of packet contention over the routes is increased by
concentrating the nodes in the resource pool on fewer switches. Of course, if
you can place all the nodes on one switch, you will resolve the issue; but in this
case, it is not possible because the pool consists of 20 nodes.
It is worth taking this issue of bisectional bandwidth into account when
partitioning the system, and when you have this type of resource pool where
Chapter 5. System Partitioning
133
This soft copy for use by IBM employees only.
performance across the switch is of great importance. By partitioning the
system, the nodes may have to be concentrated on the switches, therefore
reducing bandwidth.
5.2.5 Configuration Files
All the switch configuration files at PSSP 2.1 are in the following directory:
/spdata/sys1/syspar_configs
The system size directories are below this directory based on the number of
switch boards in the system (or frames, if there is no switch). For example:
/spdata/sys1/syspar_configs/1nsb0isb
Beneath these directories are the config directories which determine how many
partitions will be in the system and how many nodes will be in each one. For
example:
/spdata/sys1/syspar_configs/1nsb0isb/config.8_8
Beneath this are the layout directories which determine which nodes will go into
which partition. For example:
/spdata/sys1/syspar_configs/1nsb0isb/config.8_8/layout.1
There is a file in this directory called layout.desc that describes the actual layout
in terms of which node goes in which partition. Beneath this are the syspar
directories, one for each partition that has been selected from the config
directory. For example:
/spdata/sys1/syspar_configs/1nsb0isb/config.8_8/layout.1/syspar.1
/spdata/sys1/syspar_configs/1nsb0isb/config.8_8/layout.1/syspar.2
Within these directories there are three files: topology, nodelist and custom.
Actually, of these four files (these three plus the layout.desc), only the custom
file is a real file; all the others are symbolic links to files in the following
directories:
/spdata/sys1/syspar_configs/topologies
/spdata/sys1/syspar_configs/descriptions
/spdata/sys1/syspar_configs/nodelists
The topology file we have already discussed earlier in the chapter. The nodelist
file is similar to the layout.desc file, except that it has been split out into its
respective partition and contains only a list of its own nodes.
The custom file is the only one that gets modified. The others are selected as
supplied to match the requirements of your partitioning. The custom file gets
updated during the apply of the configuration, and this will be covered later in
more detail. It will contain information about the version of POWERparallel
System Support Programs in the partition, for example.
The diagram in Figure 62 on page 135 is intended to assist in the understanding
of the directory structure, although you only really need to use this information if
you need to debug problems with System Partitioning or the switch. All the
configurations can be done from the SMIT panels without this knowledge.
134
SP PD Guide
This soft copy for use by IBM employees only.
Figure 62. Directory Structure for the Topology Files in PSSP 2.1
Returning to the example of an 8_8 configuration, following is a list of all the
associated topology files:
/spdata/sys1/syspar_configs/topologies/any.l1.8way1.0isb
/spdata/sys1/syspar_configs/topologies/any.l1.8way2.0isb
/spdata/sys1/syspar_configs/topologies/any.l1.8way3.0isb
/spdata/sys1/syspar_configs/topologies/any.l1.8way4.0isb
/spdata/sys1/syspar_configs/topologies/any.l1.8way5.0isb
/spdata/sys1/syspar_configs/topologies/any.l1.8way6.0isb
/spdata/sys1/syspar_configs/topologies/any.l2.8way1.0isb
/spdata/sys1/syspar_configs/topologies/any.l2.8way2.0isb
/spdata/sys1/syspar_configs/topologies/any.l2.8way3.0isb
/spdata/sys1/syspar_configs/topologies/any.l2.8way4.0isb
/spdata/sys1/syspar_configs/topologies/any.l2.8way5.0isb
/spdata/sys1/syspar_configs/topologies/any.l2.8way6.0isb
Note that there are 12 files, 6 beginning with any.l1 , and 6 with any.l2 . As there
are three possible layouts for an 8_8 configuration, this explains why there are
six of each because you have one topology file for each of the partitions.
In the supported configurations, it is possible to have an 8-way partition only in a
single switch/frame system or in a two switch/frame system, because in a three
or more frame system, all the nodes serviced by a switch or in a frame must be
in the same partition.
The l1 or l2 part of the filename refers to logical frame and logical frame 2 ,
respectively. The High Performance Switch has this concept of “logical frame”
because it is possible to have one switch servicing two physical frames. The 6
l1 files therefore refer to an 8-way partition in the first logical frame and the 6 l2
files similarly refer to one in a second logical frame. This is important because
within the topology file, the second digit refers to the logical frame number and
Chapter 5. System Partitioning
135
This soft copy for use by IBM employees only.
this information is essential during Estart if the Worm on the primary node is to
successfully initialize the switch in that partition.
In cases where the switch will not initialize within a partition, check that the
topology file was copied correctly into the files directory of the SDR by running
the following commands:
# cd /spdata/sys1/sdr/partitions/<IP alias>/files
# ls -l
The correct file should be listed in this directory. Take a look at the contents to
check that it contains the correct topology.
In addition, check that the SDR object class Switch_partition contains the correct
filename for the topology file that is loaded in the SDR files directory. To do this,
run the following commands:
# export SP_NAME=<syspar_name>
# SDRGetObjects Switch_partition topology_filename
The SP_NAME variable can be used to set the current partition. If this variable
is not set, then the current partition will be the primary partition as specified in
the node′s /etc/SDR_dest_info file. Commands such as SDRGetObjects will only
provide information about the current partition. This topic will be dealt with in
more detail later in the chapter. Any discrepancy in the two filenames will cause
Estart to fail.
In this example of an 8_8 configuration, using layout.1, the two files that will be
loaded into the SDR files directories for each partition should be:
•
•
/spdata/sys1/syspar_configs/topologies/any.l1.8way1.0isb
/spdata/sys1/syspar_configs/topologies/any.l1.8way2.0isb
Run the following commands to check that SDR contains the correct information
about the topology files for each partition:
# export SP_NAME=<IP alias>
# SDRGetObjects Switch_partition topology_filename
The output of this SDRGetObjects command should be:
topology_filename
any.l1.8way1.0isb
For the other partition, it should be:
topology_filename
any.l1.8way2.0isb
It does not matter that you have multiple topology files in the files directory of
the SDR (although it may be preferable to remove redundant ones), as long as
the Switch_partition object class is pointing to the correct one.
Debugging the switch on a partitioned system is similar to that on an
unpartitioned system. The specific differences will be covered throughout this
chapter, but the fundamentals remain the same. To recap briefly some of the
actions that may be appropriate in these circumstances:
136
SP PD Guide
•
Run errpt on all nodes to look for switch or Worm errors.
•
Look at the log files in /var/adm/SPlogs/css on the primary node in the
partition.
•
Ensure /etc/SP exists on the primary node in the partition.
This soft copy for use by IBM employees only.
•
Ensure the file /etc/SP/expected.top does not exist on the primary node in
the partition.
•
Check that the Worm daemon is running on the primary node in the partition
and on all the other nodes.
For more details on these and other appropriate debugging options, refer to
Chapter 4, “The Switch” on page 87.
5.3 Creating Partitions
Once you have decided how to partition the system, all you need to do is to
apply the chosen configuration. There are some prerequisites, however, that
should be considered.
5.3.1 Prerequisites to System Partitioning
Always ensure there are at least two boot/install servers set up for AIX Version
3.2.5 nodes prior to upgrading or reinstalling the Control Workstation to AIX
Version 4.1. (Of course, if there is to be no AIX Version 3.2.5 partition, then this
simplifies things somewhat.)
After the migration or reinstallation of the Control Workstation, verify that all the
required products are installed by running:
# lslpp -l | grep ssp
In particular, ensure that ssp.top is installed to provide the topology files for
System Partitioning. In addition, ensure that the latest maintenance is applied to
the POWERparallel System Support Programs products to avoid the added
complication of encountering any known problems 4.
If the system was previously installed at AIX Version 3.2.5, it is a good idea to
run with the AIX Version 4.1 Control Workstation for a period of time to ensure
that the installation was successful for all components of the POWERparallel
System Support Programs. The AIX Version 3.2.5 nodes can run in production
mode, and there will then be confidence that the installation was completely
successful.
After this period, prepare the nodes that are to run AIX Version 4.1 for
installation by running setup_server5 . Further detail about setup_server script
can be found in Appendix A, “RS/6000 SP Script Files” on page 229 under A.3,
“The setup_server Script” on page 239.
If all the nodes are to be installed at AIX Version 4.1, then the installation can
proceed normally and the partitioning can be set up as required when the time
is appropriate. However, if there are to be mixed partitions (that is, both AIX
Version 4.1 and AIX Version 3.2.5 partitions), then the System Partitioning must
be applied before the AIX Version 4.1 nodes are installed. The current situation
is that mixed nodes in a partition are not supported because there are a number
of problems associated with having this type of environment.
4
Contact your IBM Support Center to obtain guidance on the PTFs you should install.
5
Refer to the SP Installation Guide , GC23-3898 for details on this procedure.
Chapter 5. System Partitioning
137
This soft copy for use by IBM employees only.
Prepare for System Partitioning by setting up an IP alias for each additional
partition that is to be created. The IP alias function is provided in the standard
implementation of TCP/IP in AIX. It allows the association of more than one IP
address with a network interface. For partitioning to work, it is essential that an
alias is created for the interface that is associated with the hostname of the
Control Workstation. To find out the hostname, use the hostname command on
the Control Workstation. To find out which interface is associated with the
Control Workstation hostname, run the following command:
# netstat -r | grep <hostname of CWS>
The output of this command will show which interface to create the alias names
for. Typically the interface will either be en0, tr0, or fi0. Following is an example
of how to create an alias for the en0 network interface:
# ifconfig en0 alias 9.180.6.198 netmask 255.255.255.0 up
Check that the IP alias became associated with the adapter by running the ping
command. For example:
# ping 9.180.6.198
Ensure that the IP address used is not already in use by another system on the
network. In addition, ensure that there will not be a conflict in the future should
you add any additional nodes. Choose an IP address that will be definitely out of
the range even if you upgrade your RS/6000 SP by adding a large number of
nodes.
The next step is to ensure that the IP alias that has just been set up can be
resolved by the name resolution mechanism. If you are using the /etc/hosts file
for this purpose, then simply add the IP address and an appropriate name.
(These hostnames will be used to identify your partitions when carrying out
system administration tasks on the RS/6000 SP, so bear this in mind when
choosing the names.) Propagate these changes to the nodes either manually by
using ftp, for example, or by using one of the POWERparallel System Support
Programs commands like supper or pcp.
If you are using the product Network Information Services (NIS), for example,
ensure that you have a route set up to get to a NIS server from the IP alias
address. Check to see which route is being used for the Control Workstation IP
address so that the same route can be used for the IP alias, should this be
appropriate. Add the aliases to the NIS maps and ensure all slave servers are
updated by running a yppush. It is a good idea to have slave servers on the
nodes because if name resolution is not quick and efficient many of the
administrative tools on the RS/6000 SP will not function properly. Following is an
example for adding a route for the alias 9.180.6.198:
# route add -net 9.180.3.0 netmask 255.255.255.0 9.180.6.198
Check that name resolution is working for the aliases by running:
# host <alias name>
In addition, ensure that the IP alias is persistent after a system reboot by adding
the details of the ifconfig described previously, to the rc.net file so that it will
run each time from the /etc/inittab.
If name resolution is not working, the following steps will not be successful when
the attempt is made to set up System Partitioning. Resolve the network
problems at this stage and only then continue setting up the partitions.
138
SP PD Guide
This soft copy for use by IBM employees only.
5.3.2 Process Overview
If everything is successful so far, the next steps can all be carried out from the
SMIT menus by running:
# smit syspar
A menu will appear, as shown in Figure 63.
System Partition Configuration
Move cursor to desired item and press Enter.
Archive System Data Repository
Select System Partition Configuration
Display Information for Given Configuration or Layout
Select System Partition Layout
Enter Customization Information for a Selected System Partition
Apply System Partition Configuration
Restore System Partition Configuration
F1=Help
F9=Shell
F2=Refresh
F10=Exit
F3=Cancel
Enter=Do
F8=Image
Figure 63. SMIT M e n u for the Fastpath ″ syspar ″
Carry out the steps in the order presented in the menu, starting at the top with
Archive System Data Repository. The flow chart shown in Figure 64 on
page 140 matches these steps.
Verifying the configuration can be done at the menu Apply System Partition
Configuration.
Chapter 5. System Partitioning
139
This soft copy for use by IBM employees only.
Figure 64. Flow Chart of the System Partitioning Process
The 2nd, 3rd, and 4th steps in the SMIT menu (Select System Partition
Configuration, Display Information for Given Configuration or Layout, and Select
System Partition Layout) are represented by the single box list/select configs in
the flow chart. These SMIT menus can be used to assist in deciding how to
partition the system, but system partitioning can also be done manually by
following the guidelines regarding the directory structure previously given in this
chapter.
The cshutdown and cstartup commands can be run from the spmon GUI, or from
the command line, when the affected nodes are to be shut down or started up.
5.3.3 Archiving the SDR
Always begin the System Partitioning by archiving the SDR. It is possible to
return to the original configuration by reapplying it, but this could involve a
considerable amount of work and requires detailed knowledge of System
Partitioning and the related subsystems. Archiving the SDR can be done from
SMIT or the command line. Either way, the command run will be:
# /usr/lpp/ssp/bin/SDRArchive
Make a note of the name of the archive, because this command may have been
run multiple times, leaving several files in the following directory:
/spdata/sys1/sdr/archives
It should be easy to identify the backup just taken, because the filename is
appended with the time. For example:
backup.96124.0926
After the backup part of the name, the year is listed, followed by the Julian day
(that is, the number of days into the year), and then the time as the suffix.
140
SP PD Guide
This soft copy for use by IBM employees only.
5.3.4 Customizing the Partitions
Having selected the configuration (based on the number of switch boards or
frames in the system), chosen the layout you require (based on which nodes are
required in which partition), and selected that layout, the task of customizing
each of the partitions should be carried out. Figure 65 shows the SMIT menu to
Enter Customization Information for a selected System Partition:
Enter Customization Arguments for this System Partition
Type or select values in entry fields.
Press Enter AFTER making all desired changes.
[Entry Fields]
System Partition Name or IP Address
PSSP Code Level
Default Install Image
Primary Node
Backup Primary Node
System Partition Path
F1=Help
Esc+5=Reset
F9=Shell
F2=Refresh
F6=Command
F10=Exit
[spcws]
PSSP-2.1
[default]
[1]
[]
config.8_8/layout.1/syspar.1>
F3=Cancel
F7=Edit
Enter=Do
F4=List
F8=Image
Figure 65. Example of SMIT Screen for Customizing Layouts
Fill the fields according to the chosen configuration.
The first field System Partition Name or IP Address should contain the hostname
or the IP address for the partition that is described in the layout that is chosen
for customization. In the preceding example, this is layout.1 . It is important to
know which nodes are going to be in this partition. If you have an AIX Version
3.2.5 partition, this should be associated with the hostname of the Control
Workstation so that it becomes the default partition. All the nodes in the
partitions that are not associated with the hostname of the Control Workstation
(that is, associated with an IP alias) are known as affected nodes. It is these
nodes that must be shutdown before applying the System Partitioning.
The second field PSSP Code Level refers to which version of the POWERparallel
System Support Programs will be running in the partition. Use the F4 function
key to obtain a list, then make the correct choice.
The third field Default Install Image should match the mksysb image that has
been set up to install the node. This may not be used now if the nodes are not
to be reinstalled at this stage, and the details can always be changed at a later
date by running the setup_server command.
The fourth field Primary Node should be chosen from the list generated by
pressing F4. Each partition will have its own primary node for switch operations.
Chapter 5. System Partitioning
141
This soft copy for use by IBM employees only.
The next field, Backup Primary Node, may not be present on the SMIT screen. If
recent maintenance has been applied to the system, it may be there because
this functionally was introduced with the new code for the SP Switch. If this field
is present but the High Performance Switch is installed on the system, leave this
field blank; otherwise refer to the previous chapter on the switch for
recommendations on which node to choose as the backup primary node . If you
have an SP Switch installed but do not have this menu option, then it is essential
that the required maintenance is installed to support this new switch.
The last field refers to the partition that is being customized. This procedure
must be completed separately for each of the respective partitions.
When the OK message is displayed after Enter has been pressed, the data that
had been entered will have been placed in a file called custom. Based on the
example above, this will be in the directory:
/spdata/sys1/sypar_configs/1nsb0isb/config.8_8/layout.1/sypar.1
Here is a custom file based on this example:
sypar-name:
IP-address:
primary-node:
default-install-image:
PSSP-code-level:
backup-primary-node:
spcws
9.180.60.199
1
default
PSSP-2.1
default
Always check after the customization of the partitions that these files were
created in their respective syspar directories and that the contents are correct.
In the example used, this is the custom file for the default partition because it is
associated with the hostname of the Control Workstation.
5.3.5 Verify the Configuration
Always verify the configuration before attempting to apply it. This is done at the
SMIT menu Apply System Partition Configuration. Figure 66 on page 143 shows
an example of this menu:
142
SP PD Guide
This soft copy for use by IBM employees only.
Apply System Partition Configuration
Type or select values in entry fields.
Press Enter AFTER making all desired changes.
[Entry Fields]
Verify only.
No. Discontinue
config.8_8/layout.1
System Partition Apply Option
Correct VSD configuration?
System Partition Path
F1=Help
Esc+5=Reset
F9=Shell
F2=Refresh
F6=Command
F10=Exit
F3=Cancel
F7=Edit
Enter=Do
+
+
F4=List
F8=Image
Figure 66. Example of SMIT Screen for Verifying the Configuration
Be particularly careful at this menu because the default for the first field System
Partition Apply Option is to apply this configuration . Toggle to the Verify only
option using the tab key which will run the spapply_config command with the -v
flag and will not actually run the apply .
The second field, Correct VSD configuration, can be left at the default No.
Discontinue unless you want to correct any inconsistencies that may be apparent
in the VSD setup in relation to the new partitions. The fundamental issue is
often that the VSDs are spanning more than a single partition. Resolve these
issues before you begin System Partitioning, because only non-fatal errors can
be corrected by using this option that passes the -F to the verparvsd command.
By choosing No. Discontinue , the verparvsd which gets called from
spapply_config will exit if any non-fatal errors are encountered.
A common error that is generated by running verify details the fact that the
nodes are still up. This is merely a warning at this stage to remind you that the
affected nodes should be shutdown prior to the apply . Here is an example of this
message:
spapply_config: 0022-149 Warning: node: 1 in system partition spcws
has host_responds value of: 1 .
The host_responds value of 1 indicates that the node is up. A value of 0
indicates that the node has lost connectivity across the en0 interface and could
therefore be down.
If the verify fails, then rerun the customize operation and try again. If it
persistently fails, it is likely to be for one of the following reasons:
1. The layout.desc file does not exist in the layout directory.
2. One of the nodelist, custom, or topology files does not exist in one of the
syspar directories.
3. The data in the custom file cannot be read, is incorrect, or is inconsistent.
Chapter 5. System Partitioning
143
This soft copy for use by IBM employees only.
4. The SDR is not up or is not responding.
5. The current data in the SDR that relates to the partitioning has
inconsistencies or is incorrect.
Check and correct any problems associated with points 1, 2, and 3. If everything
is correct in these areas, then proceed to the next section to find out how to
resolve problems with the SDR.
5.3.6 Applying the System Partitioning
The key step at this point is to ensure that all affected nodes are shutdown. This
is critical to the health of these nodes in the newly-partitioned environment.
Shutting them down is the best way to guarantee that all the daemons and files
will be configured correctly in the new partitions. Shut the nodes down in the
correct manner according to the normal working procedures on the system (that
is, in the correct order from the spmon GUI or the command line).
When the spapply_config command is run (without the -v flag), the following
tasks are carried out:
•
The SDR is restructured for the partitions and the multiple daemons are
created and started.
•
The heartbeat and host_responds are restructured and the multiple daemons
are created and started.
•
The switch gets configured according to the new partitions (if there is one
installed).
•
Validates that the VSD configuration is consistent with the partition being set
up.
If the apply fails, then record the error message that appears on the SMIT
screen. In order to debug this further, read the following sections about the SDR
and heartbeat subsystems.
5.3.7 Validating the Partitions and Restoring the SDR
The option remains to restore the SDR that was archived earlier in the
procedure, but it is worth understanding why the apply failed in case the same
problem occurs the next time you attempt to implement System Partitioning.
To restore the SDR, go to the SMIT menu Restore System Partition
Configuration, list the archived files, and select the appropriate backup or
archive to restore. This will run the following command:
# /usr/lpp/ssp/bin/sprestore_config
This script restores the original SDR and reverses the actions carried out in the
apply of the partitions. For example, it will stop and remove the multiple
daemons.
Even if the apply was successful, it is still a good idea to run the following
command to verify that the partitioning configuration is good in the SDR before
the affected nodes are rebooted:
# splstdata -p
The spapply_config command calls the spverify_config command to check that
the SDR was updated correctly, but it can be run manually from the command
line as a final check.
144
SP PD Guide
This soft copy for use by IBM employees only.
Do not restore the original SDR if the affected nodes have been rebooted and
there are mixed partitions running different version of AIX and POWERparallel
System Support Programs. This situation is not supported and the effect of
running in this type of environment is unpredictable at present for compatibility
reasons. Attempting to resolve these issues is beyond the scope of this book.
5.4 SDR Reorganization
The previous section mentioned that SDR was restructured during the apply of
the System Partitioning. It is important to know how this is done in some detail
in order to resolve any outstanding problems that may arise.
5.4.1 SDR Daemons
The SDR contains all the RS/6000 SP-specific configuration information. It is a
central repository that only resides on the Control Workstation. Access to this
information is essential for all the nodes to function properly. If there are any
SDR or SDR error messages, it is a good idea to check that the SDR daemon
(sdrd) is running. This can be done by running the following command on the
Control Workstation:
# ps -ef | grep sdr
In the example that has been used so far, the output for the process name from
the preceding command should look like:
/usr/lpp/ssp/bin/sdrd 9.180.6.199
/usr/lpp/ssp/bin/sdrd 9.180.6.198
Alternatively, the following command can be run to check the same information:
# lssrc -g sdr
Here is an example of the output from this command:
Subsystem
sdr.spcws
sdr.sppart2
Group
sdr
sdr
PID
Status
10704 active
10962 active
The subsystem names are uniquely identified by using the name of the partition,
rather than the IP address, as a suffix.
In PSSP 2.1, there is one SDR daemon for each partition. Each daemon
uniquely identified by an IP address. In the case of the default partition,
the IP address associated with the hostname of the Control Workstation.
case of the other partitions, this address is the IP alias that was defined
partition.
is
this is
In the
for each
A look at the /etc/services shows that the SDR daemons are listening on TCP
port 5712. Each node can connect to this port by specifying the IP address
associated with its partition (the IP alias or the hostname of the Control
Workstation) and making a socket connection. In this way, each SDR daemon is
able to communicate only with the nodes in the partition that it associates with.
In PSSP 2.1, the SDR daemons are under SRC master control. The inittab entry
should look like the following:
sdrd:2:once:/usr/bin/startsrc -g sdr
Chapter 5. System Partitioning
145
This soft copy for use by IBM employees only.
The startsrc uses the -g flag in order to start the multiple daemons. It runs the
following script to start up the daemons and ensure that multiple instances of the
same daemon do not get created:
/usr/lpp/ssp/bin/sdr
This script passes the IP address associated with the partitions to the respective
daemons.
If there are SDR problems on a particular system, always check that all the
respective SDR daemons are running. If not, then run:
stopsrc -g sdr
startsrc -g sdr
Also ensure that the daemons remain up after restarting them. If they are dying,
then check in the following directory for log files to get an indication of why this
is happening:
/var/adm/SPlogs/sdr
These logs are covered in more detail later in the chapter.
The SP_NAME variable is not set by default. The user needs to explicilty set and
export this variable; otherwise the following file is referenced:
/etc/SDR_dest_info
In the example used, this file contains the following:
default: 9.180.6.199
primary: 9.180.6.198
This file was actually taken from one of the affected nodes because the IP
address of the primary is the IP alias given to the second partition created (that
is, not the default).
Following is the /etc/SDR_dest_info file from a node in the default partition:
default: 9.180.6.199
primary: 9.180.6.199
Both the default and the primary are set to the IP address associated with the
hostname of the Control Workstation. The node knows how to communicate with
the SDR.
The default entry in the file serves two purposes. The first is that whenever the
node is rebooted, the rc.sp script that runs from the inittab does the following as
part of its function:
•
•
•
Gets the default IP address from the /etc/SDR_dest_info file on that node.
Contacts the SDR and checks the global object class Syspar_map to find out
whether the IP address entry in the /etc/SDR_dest_info file for the primary is
correct.
If it is not correct, then it will update the SDR_dest_info with the correct
entry.
This is a critical step in getting partitioning to work and is one of the reasons
why the affected nodes should be shutdown. The reboot ensures that the
/etc/SDR_dest_info file is updated with the new IP alias address.
The second reason for having a default IP address is that if the partition gets
deleted by restoring an archive of the SDR, or by applying a different partition,
146
SP PD Guide
This soft copy for use by IBM employees only.
then the node can still reach the SDR by using this IP address (after failing to
connect to the primary ).
In the example used, if there was an AIX Version 3.2.5 partition, the contents of
the /etc/SDR_dest_info file would be:
backup: spcws
opstation: spcws
Additional code had to be written to allow more than one AIX Version 3.2.5
partition because the AIX Version 3.2.5 nodes had no concept of System
Partitioning. Originally there was no mechanism to allow AIX Version 3.2.5
nodes to be in different partitions. Updating the SDR_dest_info files on affected
AIX Version 3.2.5 nodes was an addition that was made.
If there are problems after partitioning the system, particularly in relation to the
host_responds showing red on the spmon GUI for certain nodes, then carry out
the following commands for the problematic partition:
# export SP_NAME=<syspar name>
# SDRGetObjects Syspar_map
Ensure all the /etc/SDR_dest_info files on the problematic nodes have the
correct IP address for the primary entry (or equivalent opstation for AIX Version
3.2.5 nodes) by referring to the output of the SDRGetObjects command previously
run. Correct any erroneous entries by using a text editor such as vi and then
run the following commands:
# stopsrc -g hb
# startsrc -g hb
Or, if this is an AIX Version 3.2.5 partition:
# ps -ef | grep ccst
# kill <PID of ccst process>
If the ccst process is not running, then attempt to start it manually by running:
/usr/lpp/ssp/bin/hb
The last part of this procedure involves stopping and starting heartbeat
daemons. This is dealt with in more detail in 5.5, “Heartbeat Reorganization” on
page 152.
5.4.2 SDR Directory Structure
The SDR directory structure was radically changed at PSSP 2.1 partly to
accommodate the requirements of System Partitioning. It is no longer located in
/var/sdr on the Control Workstation, as was the case in AIX Version 3.2.5, but
instead can be found in:
/spdata/sys1/sdr
Figure 67 on page 148 shows a diagram that illustrates the first level directory
structure below the sdr directory:
Chapter 5. System Partitioning
147
This soft copy for use by IBM employees only.
Figure 67. Data Organization of the SDR in PSSP 2.1
The SDR object classes have been split into two types: object classes that are
systemwide:
/spdata/sys1/sdr/system
and object classes that are specific to the partitions:
/spdata/sys1/sdr/partitions
The templates or definitions for the names of the attributes contained in all the
object classes are now found in a separate file from the actual data. These
definitions can be found in:
/spdata/sys1/sdr/defs
Each partition has its own directory identified by its associated IP address (IP
alias or Control Workstation IP address). In the example given, the following
directories exist:
/spdata/sys1/sdr/partitions/9.180.6.199
/spdata/sys1/sdr/partitions/9.180.6.198
The switch topologies are stored in the respective partition directories in a
subdirectory called files . In the example given:
/spdata/sys1/sdr/partitions/9.180.6.199/files/SDR.expected.top.any.l1.8way1.0isb
/spdata/sys1/sdr/partitions/9.180.6.198/files/SDR.expected.top.any.l1.8way2.0isb
The diagram shown in Figure 68 on page 149 gives examples of the object
classes that are systemwide and those that are partition-specific.
148
SP PD Guide
This soft copy for use by IBM employees only.
Figure 68. PSSP 2.1 SDR Directory Structure
5.4.3 New Object Classes
Two completely new object classes have been created for System Partitioning.
The Syspar_map object class has already been mentioned earlier. It is a
systemwide or global class that describes which nodes are in which partition.
Running the following command:
# SDRGetObjects Syspar_map
in the example given produces the output:
syspar_name
spcws
spcws
sppart2
sppart2
spcws
spcws
sppart2
sppart2
spcws
spcws
sppart2
sppart2
spcws
spcws
sppart2
sppart2
syspar_addr node_number switch_node_number used
9.180.6.199
1
0
1
9.180.6.199
2
1
0
9.180.6.198
3
2
1
9.180.6.198
4
3
0
9.180.6.199
5
4
1
9.180.6.199
6
5
1
9.180.6.198
7
6
1
9.180.6.198
8
7
1
9.180.6.199
9
8
1
9.180.6.199
10
9
1
9.180.6.198
11
10
1
9.180.6.198
12
11
1
9.180.6.199
13
12
0
9.180.6.199
14
13
0
9.180.6.198
15
14
0
9.180.6.198
16
15
0
From this output, it is possible to see that there are two wide nodes and eight
thin nodes from the used field. The 0 signifies that the slot is not used. Run this
command if there are problems with the partitions. If there is any erroneous
data, the health of the partitions will be affected. It is possible to edit manually
Chapter 5. System Partitioning
149
This soft copy for use by IBM employees only.
the object class with a program such as vi, but be sure to copy the object class
to a safe place first should the file become inadvertently corrupted.
Also, because the SDR daemon was bypassed during this operation, it is
essential to refresh the relevant daemon (that is, the one for that partition) so
that the change can take effect. Use the stopsrc and startsrc commands, as
shown in previous examples.
The second object class that gets created is Syspar , which is a partition-specific
class (so there is one for each partition) that contains all the attributes that were
entered in the SMIT fields when the partition was customized. Run the following
commands if you have problems with a particular partition:
# export SP_NAME=<syspar name>
# SDRGetObjects Syspar
The data should match the data contained in the custom file that was created
during the customization of the partition. Ensure that the data is consistent
between the SDR and the custom file, and correct any errors. Following is the
data from the SDRGetObjects command for the default partition in the example:
syspar_name ip_address install_image syspar_dir code_version
spcws
9.180.6.199 default
/spdata/sys1/sypar_configs/1nsb0isb
/config.8_8/layout.1/syspar.1 PSSP-2.1
The default partition is at PSSP 2.1, which is shown by the code_version
attribute. Here is the same data for the second partition:
syspar_name ip_address install_image syspar_dir code_version
sppart2
9.180.6.198 default
/spdata/sys1/sypar_configs/1nsb0isb
/config.8_8/layout.1/syspar.2 PSSP-2.1
This data is consistent with the custom file example in the previous examples.
5.4.4 SDR Locking
Now that there is the potential to have multiple SDR daemons accessing the
same systemwide or global object classes, there is the requirement to have a
persistent locking mechanism to prevent simultaneous updates of object classes.
The lock files are created in the following directory:
/spdata/sys1/sdr/system/locks
The file that is created contains details of the node updating the SDR and the
partition to which it belongs.
Whenever the SDR daemons are started up, they check for the presence of any
lock files in case they were left behind when an update of the SDR ended
abnormally. If any are found at this point, they are removed. This is another
good reason why it is a good idea to recycle the SDR daemons when there are
apparent SDR problems.
5.4.5 The Restructured SDR
The SDR gets reorganized during the apply stage of System Partitioning. Before
the new partitions are set up, there are some checks that are carried out by the
spapply_config command that carries out the apply of the partitioning. This
command verifies the following:
•
150
SP PD Guide
The data in the specified layout directory (see the previous section on
verifying the configuration for more details).
This soft copy for use by IBM employees only.
•
The host listed in each of the custom files has the same interface as the
hostname of the Control Workstation.
•
The SDR is up and can answer a call.
•
There is exactly one default partition whose name is the same as that stated
in the SP object class (that is, host name of the Control Workstation).
•
The existing SDR is consistent by calling the spchk_syspars command before
setting up the new partitions.
•
The command generates a list of affected and unaffected nodes based on the
current configuration and the data for the new partitions in the syspar
directories.
•
The VSDs will not span the new partitions by running the verparvsd
command.
If any errors are generated from these checks, then the spapply_config
command will quit there and report an error. All of the issues have been
discussed previously, so run back through the details to rectify the situation.
When all these checks have been completed without error, the spapply_config
command begins the reorganization of the SDR and daemons as follows:
•
Deletes heartbeat and host_responds daemons for partitions that will not
exist in the new partitioned environment (as partitioning may previously have
been set up on the system).
•
Creates the new partitions using the SDRAddSyspar command, which creates
the new SDR directories, object classes, and SDR daemons.
•
Moves data from the original Node, Adapter, host_responds and
switch_responds to the newly-created ones, but only for the affected nodes.
•
Opens a custom file in the syspar directory to get the data to put into the
Syspar object class.
•
Updates Syspar_map object class with new information for the affected nodes
such as the syspar_name and syspar_addr .
•
After obtaining the code level of the partition, it makes and starts the new
heartbeat daemon (as the heartbeat may be in compatibility mode for an AIX
Version 3.2.5 partition).
•
Makes and starts the new host_responds daemon.
•
Adds the path to the layout directory in the SP object class.
•
Runs the partitionVSDdata command to restructure the VSD data (if it exists).
•
Deletes any partitions that no longer exist in the newly-partitioned system by
running the SDRRemoveSyspar command, which deletes the SDR daemon and
SDR data associated with the partition.
•
Sets up the switch in each partition by running Eprimary, Eannotator, and
Etopology. This loads the new topology file into the SDR, which is then ready
to run the Estart command when the nodes are available.
•
Verifies that the data in the SDR is correct by running the command
spverify_config, which checks against the original data supplied in the
syspar directory.
If there are any errors, then check manually in the relevant SDR object classes.
Check that the newly-created data was copied from the syspar directory without
any errors, and similarly, that the data got moved from the existing object
Chapter 5. System Partitioning
151
This soft copy for use by IBM employees only.
classes (such as Node , for example). In addition, look at the relevant log files for
the SDR which can be found in the following directory:
/var/adm/SPlogs/sdr
Here there are various types of files. The detailed output from the daemons is
found in SDR_config.log. Use the tail command to view the last entries made in
this file. There are also two files for each SDR daemon that have basic
information about the last two invocations of the daemon. These files have the
format:
sdrlog.<IP address of syspar>.PID
5.5 Heartbeat Reorganization
The heartbeat has been mentioned several times already because it is an
important part of the administration of an RS/6000 SP and it is also affected by
System Partitioning. Now we will look at the heartbeat in more depth.
5.5.1 The Heartbeat before System Partitioning
The heartbeat on an RS/6000 SP is used to monitor connectivity to the nodes and
the Control Workstation across the en0 network interface. It is often regarded as
the indicator of whether a node is up or not, but the loss of connectivity across
en0 does not always signify this, since the node may be up but the connectivity
on this interface may be lost.
The heartbeat daemon runs on each node and the Control Workstation. At PSSP
2.1, the daemon is called hbd; at PSSP 1.2, it is known as ccst. Run the following
commands to check if the daemons are running at PSSP 2.1:
# ps -ef | grep hbd
and at PSSP 1.2:
# ps -ef | grep ccst
Here is an example of the output from these commands showing just the process
name at PSSP 2.1:
/usr/lpp/ssp/bin/hbd -p0 -u
and at PSSP 1.2:
/usr/lpp/ssp/bin/ccst -p0
The ccst daemon will only be running on AIX Version 3.2.5 nodes. These
daemons are started from the following inittab entries, at PSSP 2.1:
hb:2:once:/usr/bin/startsrc -g hb >/dev/null 2>/dev/console
and at PSSP 1.2:
hb:2:respawn:/usr/lpp/ssp/bin/hb >/dev/console 2>&1
At PSSP 2.1, the heartbeat was brought under SRC control for the same reasons
given earlier about the SDR daemons.
Each daemon heartbeats or pings to its nearest neighbor in a ring fashion from
the highest to the lowest IP address. The Control Workstation is known as the
group leader because it coordinates the activity of all the other heartbeat
daemons on the nodes. You can logically view the Control Workstation as
starting the ping to the node with the highest IP address, which then pings to the
152
SP PD Guide
This soft copy for use by IBM employees only.
node with the next highest IP address (and so on), until the ring is completed by
the node with the lowest IP address pinging to the Control Workstation.
If there is no response to several retries of the ping packet within the timeout
period, that heartbeat daemon will notify the group leader that connectivity has
been lost over en0 , which will then take that node out of the ring.
The group leader will notify all the nodes of this action so that the ring can be
re-established by missing out the node from which there is no response over
en0 . The heartbeat daemon on the Control Workstation will pass the information
about this node up to the host_responds daemon on the Control Workstation,
which in turn passes it up to the SDR daemon to update the host_responds
object class of the SDR.
The spmon command uses this object to find out the host_responds status of all
the nodes. It may take a few seconds before the loss of connectivity is reflected
by the node changing from green to red on the spmon GUI due to the timeout
period mentioned before and the time taken for spmon to again read the object
class and refresh the host_responds GUI.
The heartbeat daemon on the Control Workstation will send out regular ping
packets (known as proclaim packets) to any nodes that have been marked as
missing from the ring in the host_responds object class, to test whether
connectivity has returned, and will reintegrate them back into the ring if that is
the case.
If a node goes red on the spmon GUI, run the following command:
# SDRGetObjects host_responds
Here is an example of the output:
node_number host_responds
1
1
3
1
5
1
6
1
7
1
8
1
9
1
10
1
11
1
12
0
In this example, all the nodes have en0 connectivity except node 12, which has
an entry of 0 (signifying a loss of connectivity).
In such a case, first test the connectivity manually by pinging the en0 interface.
If the ping is successful, wait a few seconds to see if spmon will refresh. If it does
not, then check that the heartbeat, SDR, and heartbeat daemons are running on
the Control Workstation, and that the heartbeat daemon is running on the
problematic node.
Examples have already been given for heartbeat and SDR, but following is an
example for the host_responds daemon. It shows how to find out if it is running,
the inittab entries, and how to start it if it has died:
# ps -ef | grep hr
Following is an example of the process name output from this command:
Chapter 5. System Partitioning
153
This soft copy for use by IBM employees only.
/usr/lpp/ssp/bin/hrd
The inittab entry:
hr:2:once:/usr/bin/startsrc -g hr >/dev/null 2>/dev/console
If it has died or did not start on boot, run:
# startsrc -g hr
The host_responds daemon (like the SDR daemon) only runs on the Control
Workstation. Remember that if the problematic node is running AIX Version
3.2.5, then check for the ccst process instead of the hbd process.
If all the daemons are running, it is still worth recycling them all just in case any
of the daemons are no longer functioning as they should.
If there is no connectivity across en0 , then test the connectivity across the other
network interfaces to the problem node. Test to see if a console can be opened
across the serial link. If there is connectivity across other interfaces, and the
node is up and working, then resolve the network issues with the en0 interface.
Here are some possible scenarios:
•
An application or process is generating a large amount of traffic across en0
so that the heartbeat times out
−
•
The internal Ethernet should ideally be dedicated to SP-related traffic for
this reason.
The interface has gone down or been corrupted
−
Check with the ifconfig command and remove and rebuild the interface
with the rmdev and mkdev commands if necessary.
If there is no connectivity across any of the interfaces, then check to see what
the status is of any users that are already logged in. If their sessions are hung
(that is, if there is no response to typing anything on the keyboard), then check
the LED display for the node using the spmon GUI.
If the node has crashed, then there will be either an 888 LED displayed, or an
associated crash code (such as 0c9, for example). In this case, reboot the node
after ensuring that it has finished taking a system dump and contact IBM support
for assistance in analyzing the dump data.
If the node shows no sign of having crashed but there is absolutely no response
at all to any commands, then force a system dump (according to the instructions
given in Chapter 8, “Producing a System Dump” on page 201), reboot the node,
and contact IBM support.
If the node responds to commands but does so in a fashion that is slower than
normal, then it may be possible to analyze the performance at this time to
identify what might be causing this problem.
5.5.2 The Heartbeat after System Partitioning
During the apply of the partitions, multiple heartbeat and host_responds
daemons get created and started. The spapply_config command uses the
information in the Syspar_map object class to identify which subsystems to build.
Each partition has one heartbeat and one host_responds daemon. Unlike the
SDR daemons, it is not possible to identify which daemon services which
154
SP PD Guide
This soft copy for use by IBM employees only.
partition by looking at the process table. However, you can run the following
commands to find out this information:
# lssrc -g hb
# lssrc -g hr
Following is an example of this output for the heartbeat:
Subsystem
hb.sppart2
hb.spcws
Group
hb
hb
PID
14302
15332
Status
active
active
PID
16582
16846
Status
active
active
and for the host_responds:
Subsystem
hr.sppart2
hr.spcws
Group
hr
hr
The partition name is appended to the daemon name to give a unique
subsystem name from which to determine which daemon is servicing which
partition.
With these distinct subsystems on the Control Workstation, each partition has its
own separate and distinct heartbeat ring. These rings function completely
independently from each other with no heartbeat traffic flowing between the
rings.
Figure 69 shows this structure.
Figure 69. Example of the Heartbeat Subsystem after System Partitioning
If there are any AIX Version 3.2.5 partitions, the heartbeat daemons on the
Control Workstation that service these will be started up in compatibility mode
(but they are still hbd daemons) so that they can communicate with the ccst
daemons on the nodes.
Chapter 5. System Partitioning
155
This soft copy for use by IBM employees only.
If there are problems with the heartbeat daemons after System Partitioning, use
the same techniques that have already been described in this chapter.
If there is a problem in one partition, it is possible to work just with the relevant
subsystem, rather than with all of them. In the example, the following
commands can be run to stop and start the heartbeat daemon:
# stopsrc -s hb.spcws
# startsrc -s hb.spcws
5.5.3 Daemons and Scripts
As with the SDR daemons, the SRC ensures that multiple instances of the
daemons are not running at the same time. It uses the following scripts to start
the respective daemons:
/usr/lpp/ssp/bin/hb
/usr/lpp/ssp/bin/hr
These scripts can be used manually to control the daemons and there are many
options that can be used. When using these, be careful not to start multiple
daemons because this will result in unpredictable host_responds information .
In the example, the heartbeat daemon can be put into debug mode on the spcws
partition by issuing the following commands:
# export SP_NAME=spcws
# /usr/lpp/ssp/bin/hb debug
This heartbeat daemon will now send all stdout to the console to make debug
work easier when experiencing problems with this subsystem. Since stderr
always goes to the console by default, this may provide additional information
that assists in resolving heartbeat problems. To turn this option off, issue:
# /usr/lpp/ssp/bin/hb debug off
Rather than sending this output to the console, it is possible to send this output
to a file by changing an attribute in the ODM. The SRC references an object
class in the ODM called SRCsubsys which contains information about all the
subsystems under its control. The following command can be run for any
partition:
# odmget -q ″subsysname=hb.<syspar_name>″ SRCsubsys
For the example of the partition spcws, the output is:
SRCsubsys:
subsysname = ″hb.spcws″
synonym = ″″
cmdargs = ″-spname spcws -splevel PSSP-2.1 ″
path = ″ / usr/lpp/ssp/bin/hb″
uid = 0
auditid = 0
standin = ″ / dev/null″
standout = ″ / dev/null″
standerr = ″ / dev/console″
action = 2
multi = 0
contact = 3
svrkey = 0
svrmtype = 0
priority = 1
signorm = 0
156
SP PD Guide
This soft copy for use by IBM employees only.
sigforce = 0
display = 1
waittime = 20
grpname = ″hb″
Turning on debug merely changes the ODM attribute for stdout and refreshes the
relevant daemon. Follow the next example, substituting the partition name in
order to redirect output to a file:
# odmget -q ″subsysname=hb.spcws″ SRCsubsys > <filename>
# cp /etc/objrepos/SRCsubsys /etc/objrepos/SRCsubsys.orig
# odmdelete -q ″subsysname=hb.spcws″ -o SRCsubsys
Edit <filename>, and change the stdout and stderr to a file where the data is to
go, then:
# odmadd <filename>
# stopsrc -s hb.spcws
# startsrc -s hb.spcws
There are no specific heartbeat log files, so this method may come in useful if
you are experiencing problems that cannot readily be resolved. It is worth
looking at the file:
/var/adm/SPlogs/SPdaemon.log
since there may be a reference to the heartbeat here.
The host_responds daemon does have a specific log, which is:
/var/adm/SPlogs/spmon/hr.log
The heartbeat daemons can provide information to the VSD daemons had and
hcd if they are installed. The heartbeat daemons will start up with the -p1 flag
set if they are required to wait for these VSD daemons. Otherwise, the heartbeat
daemons get started with the -p0 flag and this operation is bypassed. The
examples given earlier in the chapter show how this can be viewed in the
process table.
5.6 Resource Manager Reorganization
It was mentioned earlier that Resource Manager gets partitioned also. In fact
Resource Manager views each system partition as a separate logical partition.
Each partition that runs a Resource Manager has a completely separate
configuration file called:
jmd_config.<syspar_name>
Each partition has its own primary and backup Resource Manager. As a result,
nodes can only be allocated to resource pools within their own partition.
The jm commands all run against the partition specified by the SP_NAME
variable. This variable can be set to whichever partition the commands need to
be run against.
There is no difference in the methods used to resolve Resource Manager
problems on a partitioned system except that care needs to be taken so that the
SP_NAME is set to the partition you are experiencing problems with.
Chapter 5. System Partitioning
157
This soft copy for use by IBM employees only.
158
SP PD Guide
This soft copy for use by IBM employees only.
Chapter 6. Error Logging
The RS/6000 SP uses the AIX and BSD error logging mechanism to handle error
generation and error reporting. The trend is to use AIX error logging
exclusively, but PSSP 2.1 uses some public domain codes, such as AMD, NTP,
Supper, and so on. Therefore the BSD syslog daemon must be present.
The PSSP code also provides a specific daemon for SP-specific error log entries
like power supplies, fans, and (in general) errors detected by the hardmon
daemon. This splogd daemon also interacts with the BSD syslog daemon and
with the AIX errdemon daemon.
6.1 Error Logging Overview
The error logging facility records hardware and software failures in the error log
for information purposes or for fault detection and correction. In AIX Version 4.1,
some of the error log commands are delivered in an optionally-installable
package called bos.sysmgt.serv_aid.
The base system bos.rte includes the services for logging errors to the error log
file and the errlog subroutines, the errsave kernel service, the error device
driver /dev/error, the error daemon, and the errorstop command.
The commands required for licensed program initialization, errinstall, and
errupdate are also included in bos.rte.
System dump commands are also included in the bos.sysmgt.serv_aid (for
example, the sysdumpstart command).
To determine if this package is installed, run the command:
# lslpp -l | grep bos.sysmgt.serv_aid
If the package is installed, a line containing the following will be displayed:
bos.sysmgt.serv_aid
4.1.4.0
COMMITTED
Software Error Logging and
If the package is not installed, you can use SMIT or use the installp command:
installp -xad <installation device> bos.sysmgt.serv_aid
Because the errclear, errdead, errlogger, errmsg, and errpt commands are
part of the optionally installable Software Service Aids package
(bos.sysmgt.serv_aid), you need the Software Service Aids package to generate
reports from the error log or delete entries from it.
The error logging process begins when an operating system module detects an
error. The error-detecting segment of code sends error information to the
errsave kernel or the errlog subroutine, where the information is written to the
/dev/error special file. Here, a timestamp is added to the collected data.
The errdemon daemon constantly checks /dev/error for new entries, and when
new data is written, the daemon will perform a series of operations. Before an
entry is written to the error log, the errdemon compares the label sent by the
kernel or application code to the contents of the Error Record Template
Repository. If the label matches an item in the repository, the daemon collects
additional data from other parts of the system.
 Copyright IBM Corp. 1996
159
This soft copy for use by IBM employees only.
Figure 70. Error Logging Components
To create an entry in the error log, the errdemon retrieves the appropriate
template from the repository, the resource name of the unit that caused the
error, and detailed data. If the error signifies a hardware error and hardware
vital product data (VPD) exists, the daemon retrieves the VPD from the ODM.
When accessing the error log through smit or with the command errpt, the error
log is formatted according to the error template repository and represented in
either a summary or detailed report.
The diag command uses the error log in part to diagnose hardware problems.
To correctly diagnose new system problems, the system deletes
hardware-related entries older than 90 days from the error log and
software-related entries 30 days after logging. See the errclear command lines
in the crontab file.
6.1.1 Terms Used by the Error Logging Facility
160
SP PD Guide
Error ID
A 32-bit CRC hexadecimal code used to identify a
particular failure. Each error record template has a
unique error ID.
Error label
The mnemonic name of an error ID.
Error log
The file that stores instances of errors and failures
encountered by the system.
Error log entry
A record in the system error log that describes a
hardware or software failure or an operator message.
An error log entry contains captured failure data.
error log template
A description of what will be displayed when the error
log is formatted for a report; includes information on
the type and class of the error, probable causes, and
This soft copy for use by IBM employees only.
recommended actions. Collectively, the templates
comprise the Error Record Template Repository.
6.1.2 Error Logging Commands
errclear
Deletes entries from the error log. This command can
erase the entire error log. Removes entries with
specified error ID numbers, classes, or types.
errdead
Extracts errors in the /dev/error buffer captured in the
system dump. The system dump will contain error
records if errdemon was not active prior to the dump.
errdemon
Reads error records from /dev/error and writes error
log entries to the system error log. The errdemon
also performs error notification as specified in the
notification objects in the ODM. The daemon is
started automatically during system initialization.
errinstall
Can be used to add or replace messages in the error
message catalog. Provided for use by software
installation procedures. The system creates a backup
f i l e c a l l e d < f i l e > . u n d o . The .undo file allows you to
cancel the changes you made by issuing the
errinstall command.
errlogger
Writes an operator message entry to the error log.
errmsg
Implements error logging in applications. The errmsg
command will list, add or delete messages stored in
the error message catalog. With this command you
can add text to the Error Description, Probable Cause,
User Cause, Failure Cause, Recommended Action, and
Detailed Data message sets.
errpt
Generates an error report from entries in the system
error log. The report can be formatted to give a single
line for each entry, or as a detailed listing.
errstop
Stops errdemon, which is initiated during system
initialization. Running the errstop command also
disables some diagnostic and recovery functions of
the system.
errupdate
Adds or deletes templates in the Error Record
Template Repository. Modifies the Alert log and
Report attributes of an error template. Provided for
use by software installation procedures.
6.1.3 Error Log Files
/dev/error
Provides standard device driver interfaces
required by the error log component.
/dev/errorctl
Provides non-standard device-driver
interfaces for controlling the error logging
system.
/usr/include/sys/err_rec.h
Contains structures defined as arguments to
the errsave kernel services and the errlog
subroutine.
Chapter 6. E r r o r Logging
161
This soft copy for use by IBM employees only.
/var/adm/ras/errlog
Stores instances of errors and failures
encountered by the system.
/var/adm/ras/errtmplt
Contains the Error Record Template
Repository.
The /dev/error and /dev/errorctl special files support the logging of error events.
Minor device 0 (zero) of the error special file is the interface between processes
that log error events and the errdemon daemon. Error records are written to
/dev/error by the errlog library routine and the errsave kernel service. The error
special file timestamps each error record entry.
errdemon opens /dev/error for reading. Each read retrieves an entire error
record. The format of the error records are described in the header file
/usr/include/sys/err_rec.h.
Each time a error is logged, the error ID, the resource name, and the
timestamps are recorded in Non Volatile Random Access Memory (NVRAM) so
that in the event of a system crash, the last logged error is not lost. When the
error file is started, the last error entry is retrieved from NVRAM.
The standard device driver interfaces (open, close, read, and write) are provided
for the error file. The error file has no ioctl functions. The ioctl function
interface for the error special file is provided by the errorctl special file. This
interface supports stopping the error logging system, synchronizing the error
logging system, and querying the status of the error special file.
6.2 SP Error Logging
The RS/6000 SP uses both the AIX Error Logging facilities and the BSD syslog,
as well as a number of function-specific log files to record error events on each
node.
Commands and SMIT panels are available to perform general log management.
For managing Syslog and AIX Error Log, it is necessary to install the ssp.sysman
option.
Error logging is the writing of information to persistent storage to be used for
debugging purposes. This type of logging is for subsystems that perform a
service or function on behalf of an end user. The subsystem does not
communicate directly with the end user and therefore needs to log events to a
storage location. The events that are logged are primarily error events.
Error logging for the SP uses BSD syslog and AIX Error Log facilities to report
events on a node basis. The System Monitor, the High Performance Switch, SP
Switch, and the Resource Manager components use this form of error logging.
Error log entries include a DETECTING MODULE string that identifies the
software component, module name, module level, and line of code or function
that detected the event that was logged. The information is formatted depending
on the logging facility the user is viewing. For example the AIX Error Log facility
information appears as follows:
DETECTING MODULE
LPP=<LPP name> Fn=<filename> <ID_level_of_the_file> L#=<line number>
162
SP PD Guide
This soft copy for use by IBM employees only.
The BSD syslog facility information appears as follows:
<timestamp, hostname, ID, PID>
LPP=<LPP name> Fn=<filename> <SID_level_of_the_file> L#=<line number>
Effect of Not Having a Battery on Error Logging
In a regular RS/6000 system, a battery is installed to maintain NVRAM. On an
RS/6000 SP system, there is no battery and NVRAM may be lost when the node
is powered off. AIX writes the last error log entry to NVRAM. During system
startup, the last entry is read from NVRAM and placed in the error log when the
error daemon is started. This last error log entry may be important in diagnosis
of a system failure.
On SP wide nodes, the NVRAM does have power to it as long as the node is
plugged into the frame and the frame is plugged into a power source with power.
On SP thin nodes, NVRAM is lost whenever the node is powered down. If the
last error entry is desired, the thin nodes should not be powered off. They
should reboot with the key in “Normal” position.
6.2.1 Install and Configure Error Log
Log management functions are built upon the sysctl facility, which uses the SP
authentication services. Generating parallel AIX Error Log and BSD syslog
reports and performing general log viewing require that the user issue the kinit
command to be identified to the SP authentication services. All other log
management commands additionally require that the user be defined as a
principal in the /etc/logmgt.acl file. All users defined in this file must also be
placed in the authentication (PSSP or AFS) database as a principal.
Note: Log management mostly consists of administrative tasks normally
requiring root authority, and require a user defined in the logmgt.acl file to
execute commands as the root user.
The following is an example of the /etc/logmgt.acl file:
/etc/logmgt.acl
#acl#
# This sample acl file for log management commands contains
# a commented line for a principal
#_PRINCIPAL root.admin@HPSSL.KGN.IBM.COM
# The following principal is added to be able to trim SPdaemon.log
# from cleanup.logs.ws
_PRINCIPAL rcmd.localhost
_PRINCIPAL root.admin@HPSSL.KGN.IBM.COM
_PRINCIPAL joe@HPSSL.KGN.IBM.COM
The file contains entries for the user root as principal root.admin and user Joe
as principal joe , giving them authority to execute log management commands.
The log management server functions executed by sysctl are located in
/usr/lpp/ssp/sysctl/bin/logmgt.cmds. During system initialization, an include
statement for this file is added to the default systctl configuration file
/etc/sysctl.conf.
If you want to use an alternate sysctl configuration file, it must be updated with a
statement to include the logmgt.cmds file, and the sysctld daemon must be
restarted to activate the change.
Chapter 6. E r r o r Logging
163
This soft copy for use by IBM employees only.
The following is an example of the /etc/sysctl.conf file:
/etc/sysctl.conf
#
#
#
#
#
#
#
#
#
(C) COPYRIGHT IBM CORP.
1993
ALL RIGHTS RESERVED
US GOVERNMENT USERS RESTRICTED RIGHTS - USE, DUPLICATION
OR DISCLOSURE RESTRICTED BY GSA ADP SCHEDULE CONTRACT WITH
IBM CORP.
# This points to where sysctl resides
create var buildTop /usr/lpp/ssp AUTH
# Set up the environment for the rcmd sample programs
set env(PATH) /bin:/usr/bin:/usr/ucb:/etc:/usr/etc:/usr/sbin
# Include the help commands, but override the default helpPath
create class help $buildTop/help/help.cmds
help:setPath $buildTop/help
# Include system information commands
create class sys $buildTop/samples/sysctl/sys.cmds
# Include process manipulation commands
include $buildTop/samples/sysctl/process.cmds
# Include file system commands
include $buildTop/samples/sysctl/filesys.cmds
# Include more file system commands (pdf and pfck)
include $buildTop/sysctl/bin/pdfpfck.cmds
# Include pfps commands
include $buildTop/sysctl/bin/pfps.cmds
# Include rcmds
create class rcmds $buildTop/samples/sysctl/rcmds/rcmds.cmds
# Include LogMgt commands
include /usr/lpp/ssp/sysctl/bin/logmgt.cmds
6.2.2 AIX Error Log Facility
SMIT menus as well as commands are provided to help you manage the AIX
Error Log facility.
When you execute commands related to AIX Error Log Management, you can
specify whether the command should be executed on all nodes in the current
system partition, or you can specify node names or the name of a file containing
a list of node names. The default is the local node.
To access the AIX Error Log SMIT menu, enter:
smit sperrlog
Trim AIX Error Logs
You can trim records from error logs on a set of nodes. The fast path invocation
that cleans the Error Log menu is:
smit perrclear
Configuring the AIX Error Log
You can display the configuration parameters of the AIX Error Log to the local
node. The fast path invocation for the Show Characteristics of the Error Log
menu is:
164
SP PD Guide
This soft copy for use by IBM employees only.
smit perrdemon_shw
You can alter one or more of the configuration parameters for the AIX Error Log
on a set of nodes. Because the additional entries are generated by SP System
software, the AIX Error Log file size should be a minimum of 4 MB.
The fast path invocation for the Change Characteristics of the Error Log menu is:
smit perrdemon_chg
Managing Error Templates
You can create a new error template in the Error Template repository for logging
errors. The fast path invocation for the Add an Error Template menu is:
smit padd_et
You can remove a template from the Error Template Repository using the fast
path invocation for the Error Template menu:
smit prem_et
You can display entries from the Error Template Repository to the local host by
using the fast path invocation for the Show an Error Template menu:
smit pshw_rt
6.2.3 BSD syslog Facility
SP error logging utilizes the BSD syslog facility for recording error events.
Some applications use syslog for logging errors and other events.
Administrators also find it desirable to be able to list error log messages and
syslog messages in one single report.
To access the syslog menu in SMIT, enter:
smit spsyslog
Generating Reports on BSD syslog Log Files
The syslogd daemon, which logs the errors, is configured with a file designating
filters for the incoming messages to determine their destination. The default
configuration file is /etc/syslog.conf. BSD syslog errors are classified by the
facility that is issuing the error and by the error′s priority value. Refer to syslogd
daemon later in this topic for a description and overview of facility and priority
values. Entries in the configuration file determine the destination for each error
message based on these values. Destinations can be a file, user ID or the
syslogd daemon on another machine. We recommend that error messages be
kept locally rather than forwarding to a remote syslogd daemon on another
machine, because of the increased network traffic. You can use file collections
to maintain consistent configuration of the syslog facility.
A syslog file has the following format:
MMM DD HH:MM:SS node_name resource{pid}:
mesg
Where:
MMM DD HH:MM:SS Is the timestamp: Month Day Hour:Minute:Second
node_name
The name of the node that the error occurred on
resource
The name of the failing system
Chapter 6. E r r o r Logging
165
This soft copy for use by IBM employees only.
pid
The logged process ID of the failing resource (optional)
msg
A free form error message
Important
Note that syslogd does not log the year in a record′s timestamp. The
comparisons for start and end times are done on a per record basis and can
cause unexpected results if the log is allowed to span more than one year.
Errors logged by SP components will contain in the message section the
following additional information pertaining to the logging resource:
LPP
LPP name
Fn
File name
SID
SID level of the file
L#
Line number or function
Note: You must be Kerberos-authenticated to run the psyslrpt command.
The fast path to invoke for the Generate a Syslog Report (SMIT) menu is:
smit spsyslrpt
To report to the local node all records logged by ftp for all syslog files on nodes
in the current system partition, enter:
psyslrpt -a -r ftp
To report all records that logged to files selected for the daemon and user
facilities starting on August 9 and to report the records to the local node from
the nodes sp21n1 and sp21n2, enter the following command at the command
line:
psyslrpt -w sp21n1,sp21n2 -f daemon,user -s08090000
The following is an example of the /etc/syslog.conf file:
166
SP PD Guide
This soft copy for use by IBM employees only.
# @(#)341.9 src/bos/etc/syslog/syslog.conf, cmdnet, bos411, \
9428A410j 6/13/93 14:52:39
#
# COMPONENT_NAME: (CMDNET) Network commands.
#
# FUNCTIONS:
#
# ORIGINS: 27
#
# (C) COPYRIGHT International Business Machines Corp. 1988, 1989
# All Rights Reserved
# Licensed Materials - Property of IBM
#
# US Government Users Restricted Rights - Use, duplication or
# disclosure restricted by GSA ADP Schedule Contract with IBM Corp.
#
# /etc/syslog.conf - control output of syslogd
#
#
# Each line must consist of two parts:
#
# 1) A selector to determine the message priorities to which the
#
line applies
# 2) An action.
#
# The two fields must be separated by one or more tabs or spaces.
#
# format:
#
# <msg_src_list><destination>
#
# where <msg_src_list> is a semicolon separated list of <facility>. \
<priority>
# where:
#
# <facility> is:
# * - all (except mark)
# mark - time marks
# kern,user,mail,daemon,auth, ... \
(see syslogd (AIX Commands Reference))
#
# <priority> is one of (from high to low):
# emerg/panic,alert,crit,err(or),warn(ing),notice,info,debug
# (meaning all messages of this priority or higher)
#
# <destination> is:
# /filename - log to this file
# username,username2,... - write to user(s)
# @hostname - send to syslogd on this machine
# * - send to all logged in users
#
# example:
# ″ mail messages, at debug or higher, go to Log file. \
File must exist.″
# ″ all facilities, at debug and higher, go to console″
# ″ all facilities, at crit or higher, go to all users″
# mail.debug
/usr/spool/mqueue/syslog
# *.debug
/dev/console
# *.crit
*
daemon.notice
/var/adm/SPlogs/SPdaemon.log
Figure 71. /etc/syslog.conf file
The following is an example of the /etc/syslog.pid file:
3216
Figure 72. /etc/syslog.pid file
Chapter 6. E r r o r Logging
167
This soft copy for use by IBM employees only.
The psyslrpt Command
You can use the psyslprt command to generate reports of log entries in the log
files generated on a set of nodes by syslogd. Options allow you to select the
files and records that will be reported.
Options and Parameters
-a
Generates the report on all nodes in the system partition.
-e
Reports on records before endtime (MMddhhmm).
-f facilities
Uses the facilities list to parse the syslog.conf file.
-g config
Specifies the use of an alternate syslog.conf file.
h
Displays usage information.
-l logs
(Lowercase L) Reports on the list of log files, if the syslog.conf
file is not parsed.
-n nodes
Reports records matching the nodes.
-p priority
Uses priority value to pass the syslog.conf file.
-s starttime
Reports records created after starttime (MMddhhmm).
-w hosts
Runs the command on the file or list of host names. If the
argument begins with a slash (/), it is interpreted as a file
containing a list of nodes to execute the command on. Otherwise
it can be a list of host names.
Note: If neither the -a nor -w options are used, psyslprt defaults to the local
node.
6.2.4 Trimming syslog Files
The size of the syslog log files is not configurable and will continue to grow until
you trim it manually.
The syslogd daemon is stopped during the trimming process and then restarted
with either the default configuration file (/etc/syslog.conf) or an alternate file.
To run the psyslclr command, you must be defined as a Kerberos principal in
the /etc/logmgt.acl file.
The fastpath to invoke the Trim Log Files SMIT menu is:
smit psyslclr
To trim all records older than 30 days from the log file /var/adm/msgs on the
local node, you can perform this command:
psyslclr -y 30 -l /var/adm/msgs
To trim all records from all log files found in the alternate syslog configuration
file /var/adm/syslog.conf, perform this command:
psyslclr -g /var/adm/syslog.conf -y 0
You can add the psyslclr command to the crontab to perform a scheduled
syslog trimming.
168
SP PD Guide
This soft copy for use by IBM employees only.
On the Control Workstation, psyslclr is used to trim daemon facility messages
older than 6 days. This is done in /usr/lpp/ssp/bin/cleanup.logs.ws, which is run
from the Control Workstation′s crontab file.
The SP system uses the crontabs file to periodically update file collections and
clean up log files. The installation process appends to the crontabs files in
/var/spool/cron/crontabs/root on the Control Workstation and each of the nodes.
The files contain different entries depending on their locations.
Both files on the Control Workstation and the nodes contain an entry to clean up
the logs. The following example shows the crontab entries for root on a Control
Workstation:
0 11 * * * /usr/bin/errclear -d S,O 30
0 12 * * * /usr/bin/errclear -d H 90
01 5 * * * /usr/lpp/diagnostics/bin/run_ssa_ela 1>/dev/null 2>/dev/null
0 * * * * /usr/lpp/diagnostics/bin/run_ssa_healthcheck 1>/dev/null 2>/dev/null
0 0 * * * /usr/lpp/ssp/bin/cleanup.logs.ws
If you want the same crontab file on all SP nodes, you must update all the
crontab files across the SP system. One way to do this is the following:
1. Get a crontab file from one of the node:
rsh hostname crontab -l > /tmp/crontab.nodes
2. Edit /tmp/crontab.nodes
3. Propagate the changed crontab file to all SP nodes:
dsh -a rcp root@mynode:/tmp/crontab.nodes /tmp/crontab.nodes
dsh -a ″crontab < /tmp/crontab.nodes″
Chapter 6. E r r o r Logging
169
This soft copy for use by IBM employees only.
The psyslclr Command
You can use the psyslclr command to delete log entries in the log files
generated by syslogd. There are options that allow you to select the files and
records that are trimmed, as follows:
Options and Parameters
-a
Trims logs on all nodes in the system partition.
-e
Trims records before endtime (MMddhhmm).
-f facilities
Uses the facilities list to parse the syslog.conf file.
-g config
Specifies the use of an alternate syslog.conf file.
h
Displays usage information.
-l logs
(Lowercase L) Reports on the list of log files, if the syslog.conf
file is not parsed.
-n nodes
Reports records matching the nodes.
-p priority
Uses priority value to pass the syslog.conf file.
-s starttime
Trims records created after starttime (MMddhhmm).
-w hosts
Runs the command on the file or list of host names. If the
argument begins with a slash (/), it is interpreted as a file
containing a list of nodes to execute the command on. Otherwise
it can be a list of host names.
The -f and -p options can be used to control selecting files in the configuration
file. All files found in the configuration file will be trimmed if both options are not
used. If neither the -a nor -w options are used, psyslclr defaults to the local
node.
6.2.5 Maintain Error Logs
View error logs
smit splogview
The contents of each file entry and output of each command entry on the target
nodes in the log table amd.tab can be displayed to the stdout of the node from
which you are executing the splm command. To do this, issue the following from
the command line:
splm -a view -t /spdata/sys1/logtables/amd.tab
Archive error logs
You can create, remove, or gather error log archives to a central location where
they can be (optionally) written to tape or mailed to another location.
To access the archive Logs SMIT menu, enter:
smit sparchive
The fast path to invoke to the Create Archive menu is:
smit spcreate_archive
To create an archive on each target node in the directory
/var/archives/arc_weekly.tab, issue from the command line:
170
SP PD Guide
This soft copy for use by IBM employees only.
splm -a archive -t /spdata/sys1/logtables/weekly.tab -c -d /var/archives
The fast path to invoke to the Remove Archives menu is:
smit spremove_archive
To remove all files and directories in and including /var/archives/arc_weekly.tab,
issue from the command line:
splm -a archive -t /spdata/sys1/logtables/weekly.tab -r -d /var/archives
The fast path to invoke to the Gather Archives menu is:
smit spgather_archive
To gather the compressed tar files created on each target node in the directory
/var/archives/arc_weekly.tab to the directory /var/logrepos on the local node,
issue from the command line:
splm -a gather -k archive -t /spdata/sys1/logtables/weekly.tab \
-d /var/archives -l /var/logrepos
Note: The archive and gather functions of splm require that you have a Kerberos
principal defined in the /etc/logmgt.acl file. The command then runs as root on
all target nodes.
The view function requires that you are Kerberos-authenticated to a valid user ID
on the nodes that you are executing on. The server switches IDs from root to
your authenticated ID before executing.
Chapter 6. E r r o r Logging
171
This soft copy for use by IBM employees only.
The splm Command
With this command, you can execute a number of log management functions on
a single host or a set of hosts in parallel. The splm functions are driven by a log
table file that contains the target node designations and associated files and the
commands to execute. The table format is as follows:
#comment line
<target nodes>: <file or command>
The target node portion of a table stanza is a comma-delimited list with no
blanks. The values in the list are interpreted as:
1. If the value begins with a slash (/), it is a file containing a list of node names,
one per line.
2. If the value is an exclamation point (!), it refers to the local host.
3. Any string not matching list items 1 or 2 is interpreted as a node name.
Options and Arguments
-a action
Specifies the function to perform: archive, check, gather, service, or
view.
-c
Creates a compressed tar file. The tar file will be named
node.tar.Z.
-d dir
Is the path where the archive collection will be stored on each
node. The default is /var/adm/archives.
-k type
For the gather function only, this option indicates whether a service
collection or archive is being collected.
-l cfs
Specifies the path on the local node where the archive collection
should be gathered.
-r
Removes the archive on each node.
-s
Staggers collection to a mail or to a device.
-t
Specifies the input table of nodes and commands.
Functions
Archive
The archive function copies files and redirects command output as specified in
the input table to the top level directory on each node. The -c option creates a
compressed tar file of the data named /topdirectory/node_name.tar.Z. The -r
option removes an archive by removing all files down from the top level
directory.
Gather
The gather function moves archive tar files to a central location on the executing
node. The -r option removes the archive collection on each remote node only
after the tar file was copied successfully to the central location. If the node.tar.Z
file is not found, the gather function will try to create one. Gathered tar files can
be copied to tape or disk or mailed.
172
SP PD Guide
This soft copy for use by IBM employees only.
Service
The service function first calls the snap command to gather system data to the
top level directory if the -p option is used. The snap command creates a set of
subdirectories based on the -p arguments. The additional data defined in the
table data is then collected in the other subdirectory created by the snap
command. If the -p option is not used, the data will be collected in the other
subdirectory. Note that you must have root authority to execute the snap
command.
View
The view function displays the output of the command or contents of the entries
in the input table to the local host. The following is an example of the
/spdata/sys1/amd.tab file:
#
# This is a sample service collection table for amd problems.
# To use:
#
1. Uncomment lines to be collected.
#
2. Replace the target node list for each line with node names,
#
a file containing node names, or a ! to designate the
#
local node. (See the splm reference page)
#
3. Add to the node list or add additional collection commands
#
if needed.
#
# In this table the following target nodes need to edited:
#
allnodes
All nodes in the SP system
#
amd_server
amd server node (usually the cws)
#
cws
Control Workstation
#cws,allnodes: /etc/amd/amd-maps/*
/amd-maps/
#amd_server: /etc/exports etc_exports
#amd_server: /etc/filesystems etc_filesystems
#cws,allnodes: /etc/amd/amq > amq.output
#cws,allnodes: /bin/df > df.output
#cws: /var/adm/SPlogs/amd/amd.log
Figure 73. /spdata/sys1/amd.tab
6.2.6 Collecting System Data
Create service collections
From SMIT, the fast path to invoke for the Create Service Collections menu is:
smit spcreate_collect
In the following example, service collections are created using the table file
ssp.tab. snap -gfk will be called to gather general system information ( -g), file
information ( -f), and kernel information ( -k). Additional log and system data
designated in the ssp.tab table will be collected in the other directory created by
snap. The nodename.tar.Z compressed tar file will be created.
splm -a service -t /spdata/sys1/logtables/ssp.tab -p ′ gfk′ -c
The fast path to invoke for the Remove Service Collections menu is:
smit spremove_collect
Chapter 6. E r r o r Logging
173
This soft copy for use by IBM employees only.
In the following example, we will remove the service collections created using
the table ssp.tab:
splm -a service -t /spdata/sys1/logtables/ssp.tab -r
Gather service collections
The fast path to invoke for the Gather Service Collections menu is:
smit spgather_collect
The following example will show how the compressed tar files from the nodes in
the table ssp.tab are gathered to the local node and written to the tape device
/dev/rmt0. The -s option provides a method for gathering all the compressed tar
files to tape or disk or mailing them without requiring disk space on the local
node.
splm -a gather -k service -t /spdata/sys1/logtables/ssp.tab -d /tmp -s \
-o /dev/rmt0
6.2.7 SP Error Log
It may be helpful in system problem determination to look at all error logs at
once in parallel. It is not a good idea to copy the /var/adm/ras/errlog files from
all the nodes to one central place and then run errpt against this central file, for
the following reasons:
1. The time needed for copying is added to the sequential processing time of
all nodes.
2. The total time required will be longer than that required for viewing the logs
in parallel, and longer than error log processing requires for node
information from the ODM database on each node.
Therefore it is better to use the dsh command in combination with the errpt
command and options to view the error log. To establish this, you can perform
the following:
1. View the summary information for all nodes to determine which one must be
examined more closely:
dsh -a errpt -s 0810050096 | pg
2. In the previous example, all error entries are listed that occurred after
August 10, 1996 at 5 a.m. for every node defined in the SDR.
3. Select the nodes that have error entries that need more examination.
4. View the selected nodes, as in the following example:
dsh -w sp21n1,sp21n4,sp21n10 errpt -a -s 0810050096 > /tmp/810errors
When the hardware supervisors indicate a warning or shutdown condition, the
SP System Monitor writes a message using the BSD syslog facility and the AIX
Error Log facility. For example, when the hardware supervisors determine that a
fan has failed, the SP System Monitor writes a precise message into the log file
that includes the time, node, type of error, variable name and, in some cases,
associated values.
The installation process creates the default syslog file
/var/adm/SPlogs/SPdaemon.log on the Control Workstation. You may want to
configure your system to send the system log information to other locations. For
example, you may want to send the SPdaemon.log messages to another
174
SP PD Guide
This soft copy for use by IBM employees only.
workstation for convenience. You can do this using the @hostname parameter
in the /etc/syslog.conf file.
6.3 Error Notification Facility
Following is a description of the actions to be taken by the notification method
EN_pend, located in the directory /spdata/sys1/err_methods. You can install this
method to invoke pre- and post-action scripts and mail a report of the logged
error. The script provides a suggested structure for notification methods and
can be reused with different pre- and post-action scripts.
EN_pend method flow
1. EN_pend looks in the directory it resides in for a file with the same name and
one with the envs suffix. An EN_pend.envs script is installed in the same
directory. If found, it will set the environment variables EN_RUNDEFAULT
and EN_MAILLOC.
2. EN_pend.envs sets the EN_RUNDEFAULT environment variable. It also sets
the EN_MAILLOC variable to root at the Control Workstation (or, if this is
impossible, to root at the local node).
3. EN_pend checks for a pre-action script in the same directory and name with
a .pre suffix, and executes it if found.
4. EN_pend mails an expanded report of the error using the sequence of the
error passed by the notification facility to the EN_MAILLOC. Note that this
will only happen if the variables EN_RUNDEFAULT and EN_MAILLOC are set.
5. EN_pend checks for a post-action script in the same directory and name with
a .post suffix, and executes it if found.
Installing a notification object
To add the EN_pend method to all nodes in the current partition so they will send
a report whenever an error of type PEND (loss of availability of a device is
imminent) occurs, enter the following commands:
penotify -a -n ″PEND_err″ -P -t ″PEND″ -m /spdata/sys1/err_methods/ \
EN_pend $1
penotify -a -n ″pend_err″ -P -t ″pend″ -m /spdata/sys1/err_methods/ \
EN_pend $1
penotify -a -n ″Pend_err″ -P -t ″Pend″ -m /spdata/sys1/err_methods/ \
EN_pend $1
Three objects are added with variations on PEND because uppercase is not
always adhered to by all AIX LPPs and vendor functions. The $1 argument
causes the Error Notification to pass the error sequence number to the notify
method.
Create different pre- and post-action scripts
The EN_pend and EN_pend.envs scripts can be used to invoke different pre- and
post-action scripts for different error events by creating links to them. EN_pend
looks for .envs, .pre and .post scripts in the directory it is called from and by the
same base name. In the following example, EN_pend is used for reporting
Chapter 6. E r r o r Logging
175
This soft copy for use by IBM employees only.
hdisk0 errors on the nodes sp21n7, sp21n8, sp21n9, and sp21n10, and performing
the pre- and post-actions:
1. Create .pre and .post scripts on one of the nodes. For example, create
EN_hdisk0.pre and EN_hdisk0.post in the directory /spdata/sys1/err_methods
on node sp21n7.
2. Copy the .pre and .post files to the nodes sp21n8, sp21n9 and sp21n10 using
the pcp command:
pcp -w sp21n8,sp21n9,sp21n10 EN_hdisk0.pre /spdata/sys1/err_methods/
pcp -w sp21n8,sp21n9,sp21n10 EN_hdisk0.post /spdata/sys1/err_methods/
3. Create links to the EN_pend and EN_pend.envs scripts:
dsh -w sp21n7,sp21n8,sp21n9,sp21n10 ln -s /spdata/sys1/err_methods/EN_pend
/spdata/sys1/err_methods/EN_hdisk0
dsh -w sp21n7,sp21n8,sp21n9,sp21n10 ln -s /spdata/sys1/err_methods/EN_pend.envs
/spdata/sys1/err_methods/EN_hdisk0.envs
4. Add the notification object:
penotify -w sp21n7,sp21n8,sp21n9,sp21n10 -f add -P -n ″hdisk0_err″
/spdata/sys1/err_methods/EN_hdisk0 $1 -N ″hdisk0″
To display the notification object, just created, enter:
penotify -w sp21n7,sp21n8,sp21n9,sp21n10 -f show -n ″hdisk0_err″
To remove this notification, enter:
penotify -w sp21n7,sp21n8,sp21n9,sp21n10 -f remove -n ″hdisk0_err″
Important
Notification methods need to be accessible to each node that the notify object
is added to. We recommend that the notification scripts are kept local on
each node in case of network failure. File collections should be used to
maintain updates to notification methods.
176
SP PD Guide
This soft copy for use by IBM employees only.
The following is an example of the /spdata/sys1/err_methods/EN_pend file:
#!/bin/ksh
#####################################################################
#
#
# Module: EN_pend
#
#
#
#CPRY
#
# 5765-296 (C) Copyright IBM Corporation 1995
#
# Licensed Materials - Property of IBM
#
# All rights reserved.
#
# US Government Users Restricted Rights #
# Use, duplication or disclosure restricted by
#
# GSA ADP Schedule Contract with IBM Corp.
#
#CPRY
#
#
#
#-------------------------------------------------------------------#
#
#
# Description: Default error notification script for pend errors.
#
#
#
# Syntax (example): Add as EN_pend $1
#
#
#
# Internal Ref: None
#
#
#
#####################################################################
#@(#)96 1.1 src/ssp/logmgt/bin/EN_pend, sysman, ssp_r2.4, r2_4t6d6
4/4/95 07:21:32
unset EN_MAILLOC
unset EN_RUNDEFAULT
ENVS=$0′ . envs′ ;
PRE=$0′ . pre′ ;
POST=$0′ . post′ ;
if [ -x $ENVS ]
then
. $ENVS
fi
if [ -x $PRE ]
then
echo $PRE;
fi
if [ ″ $EN_RUNDEFAULT″ != ″″ ]
then
if [ ″ $EN_MAILLOC″ != ″″ ]
then
errpt -a -l $1 > /tmp/tmprpt.$$
mail $EN_MAILLOC < /tmp/tmprpt.$$
rm /tmp/tmprpt.$$
fi
fi
if [ -x $POST ]
then
echo $POST;
fi
Figure 74. /spdata/sys1/err_methods/EN_pend
Chapter 6. E r r o r Logging
177
This soft copy for use by IBM employees only.
The following is an example of the /spdata/sys1/err_methods/EN_pend.envs file:
#!/bin/ksh
#####################################################################
#
#
# Module: EN_pend.envs
#
#
#
#CPRY
#
# 5765-296 (C) Copyright IBM Corporation 1995
#
# Licensed Materials - Property of IBM
#
# All rights reserved.
#
# US Government Users Restricted Rights #
# Use, duplication or disclosure restricted by
#
# GSA ADP Schedule Contract with IBM Corp.
#
#CPRY
#
#
#
#-------------------------------------------------------------------#
#
#
# Description: Sets up RUN_DEFAULT and MAILLOC env variables for
#
#
the EN_pend script. Must reside in the same
#
#
directory as the EN_pend script to be called.
#
#
#
#####################################################################
#@(#)97 1.2 src/ssp/logmgt/bin/EN_pend.envs, sysman, ssp_r2.4, r2_4t6d6
6/5/95 09:01:29
#!/bin/ksh
export EN_RUNDEFAULT=″ YES″ ;
export EN_MAILLOC=root
/usr/lpp/ssp/bin/SDRGetObjects SP control_workstation > /dev/null 2>&1
if [ ″ $?″ = 0 ]
then
CWS=/usr/lpp/ssp/bin/SDRGetObjects SP control_workstation \
| awk ′ NR>1′ ;
if [ ″ $CWS″ != ″″ ]
then
export EN_MAILLOC=″ root@$CWS″ ;
fi
fi
Figure 75. /spdata/sys1/err_methods/EN_pend.envs
6.3.1 Error Notification Objects
Error notification objects are ODM objects held in the class errnotify that are
used by the AIX Error Notification facility to invoke methods upon occurrence of
an error event.
Fields in the errnotify class match to fields in the Error Template for selection. If
an error is logged matching the selection criteria defined in a notification object,
the method associated with that object is invoked.
You can add, remove, and show notification objects in parallel on the RS/6000
SP system.
The fast path for the Add a Notification Object menu is:
smit padd_en
The fast path for the Remove a Notification Object menu is:
smit prem_en
The fast path for the Show a Notification Object menu is:
smit pshw_en
178
SP PD Guide
This soft copy for use by IBM employees only.
From the command line:
To add, remove, or show error notification objects in parallel on the SP system,
enter:
penotify -f show
Useful options with the penotify command are:
-a
Executes on all nodes in the system partition.
-c
Specifies the error class.
-f
Specifies the function: show, add, remove.
-m method
Specifies the notification method.
-n name
Specifies the name of the notification object.
-w hosts
Run the command on a file or a list of hosts names separated by
commas or blanks.
-P
This option will cause the object to persist after the system is
restarted.
Note that you must be defined as a Kerberos principal in the /etc/logmgt.acl file
to run this command.
To view all notification object on the nodes sp21n1, sp21n2, and sp21n3, enter:
penotify -w sp21n1,sp21n2,sp21n3 -f show
To remove the notification object named HDISK0_ERR on all nodes, enter:
penotify -a -f remove -n HDISK0_ERR
The AIX Error Notification facility can notify you when an SP error occurs. The
error notification will perform an ODM method defined by the administrator when
a particular error occurs or a particular process fails.
The following classifications of errors should have notifications defined by the
administrator. Many of these messages will not occur often, so these notification
objects should be defined even for large SP systems.
1. PPS AIX Error Label that end in _EM
The _EM suffix signifies an emergency error and is usually used to tell the
administrator some information that would be needed to reboot a node. You
can find these messages by issuing the command:
errpt -t | grep ″_EM″
2. Any AIX Error Log entries that have an Error Type of PEND
The error type PEND signifies an impending loss of availability and action
will soon be required by the administrator.
3. Any AIX Error Log entries for the boot device of the node
The boot device of the node usually is a resource of hdisk0, but the name
may vary if the installation has been customized.
4. The AIX Error Label EPOW_SUS
The EPOW_SUS error log entry is generated prior to a system power down
when an unexpected loss of electrical power is encountered.
Chapter 6. E r r o r Logging
179
This soft copy for use by IBM employees only.
5. The AIX Error Labels KERN_PANIC and DOUBLE_PANIC
KERN_PANIC and DOUBLE_PANIC error log entries are generated when a
kernel panic occurs.
6.3.2 Error Notification Object Class
The error notification object class allows applications to be notified when
particular errors are recorded in the system error log. The application describes
the set of errors to be notified of in an Error Notification object.
Each time an error is logged, the error notification daemon determines if the
error log entry matches the selection criteria of any of the error notification
objects. If that is the case, then the daemon runs the notify method of each
matched object.
The error notification object class is located in the /etc/objrepos/errnotify file.
This object file contains the following descriptors:
en_pid
Allows the owner of the error notification object to specify
a process ID for use by the Notify Method. Objects which
have a PID specified should have the en_persistenceflg set
to 0.
en_name
Uniquely identifies the object. The creator uses this
unique name when removing the object.
en_persistenceflg
Designates whether the error notification object should be
automatically removed when the system is restarted.
Valid values are:
0
non-zero
en_crid
Specifies the error identifier associated with a particular
error.
en_label
Specifies the label associated with a particular error
identifier as defined in the header file
/usr/include/sys/erridd.h.
en_class
Identifies the class of the error log entries to match. Valid
values are:
H
S
O
en_type
en_alertflg
SP PD Guide
Hardware error class
Software error class
Messages from the errlogger command
Identifies the severity of error log entries to match. Valid
values are:
PEND
PERM
Perf
TEMP
UNKN
180
Removes the error notification object at system
restart.
Retains the error notification objects at system
restart.
Impending loss of availability
Permanent
Unacceptable performance degradation
Temporary
Unknown
Identifies whether the error is alertable. This descriptor is
provided for use by alert agents associated with network
management applications. Valid values are:
This soft copy for use by IBM employees only.
TRUE
FALSE
Matches alertable errors.
Matches non-alertable errors.
en_resource
Identifies the name of the failing resource. For the
hardware error class, a valid resource name is the device
name.
en_rtype
Identifies the type of the failing resource. For the
hardware error class, a valid resource type is the device
type a resource is known by in the devices object.
en_rclass
Identifies the class of the failing resource. For the
hardware error class, a valid resource class is the device
class. The resource error class is not applicable for the
software error class.
en_method
Specifies a shell script or command string to be run when
an error matching the selection criteria of this error
notification object is logged. The notification uses the sh
-c command to execute the notify method. The following
key words are automatically expanded by the error
notification daemon as arguments to the notify method:
$1
$2
$3
$4
$5
$6
$7
$8
$9
The
The
The
The
The
The
The
The
The
sequence number from the error log entry
error ID from the error log entry
error class from the error log entry
error type from the error log entry
alert flags from the error log entry
resource name from the error log entry
resource type from the error log entry
resource class from the error log entry
error label from the error log entry
Use the en_persistenceflg to avoid erroneous signaling. Those notification
objects containing methods which send a signal to another process should
especially not persist across system restart. This is because the receiving
process and its process ID do not persist across system restarts. The creator of
the error notification object is responsible for removing the error notification
object at the appropriate time. In the event that the process terminates and fails
to remove the error notification object, the en_persistenceflg descriptor ensures
that obsolete error notification objects are removed when the system restarts.
6.3.3 Adding an Error Notification Object
The following example shows how to mail the error report to
root@controlworkstation when a switch adapter fails the online diagnostics.
Adding the dsh -a command to the ODM commands will perform the action on
all nodes of the RS/6000 SP.
1. Set up the directories for the error notification objects and methods:
mkdir /<define_path>/errnotify/objects
mkdir /<define_path>/errnotify/methods
2. Create the error notification method script.
Create the script that will be run when the error occurs. For example:
Chapter 6. E r r o r Logging
181
This soft copy for use by IBM employees only.
#!/bin/ksh
#########################################################################
# Run errpt to get the full error report for the error that
#
# was written and redirect it to a unique errnot.$$ file.
#
# $$ will expand to the PID of this script.
#
#########################################################################
errpt -a -l $1 > /tmp/errnot.$$
#########################################################################
# Mail the full expanded error report to root@controlworkstation.
#
# This is the user and the hostname that the administrator wants
#
# to be notified at. They could be anywhere in the system.
#
#########################################################################
mail root@controlworkstation < /tmp/errnot.$$
3. Create the error notification object.
Create a file that contains the error notification object to catch the tbx
diagnostic failed error. It is easier to modify an existing set of ODM errnotify
stanzas and edit the file. To do this, enter:
odmget errnotify > /tmp/errnotify.odm
Important
Include only the attributes that have values.
If you want to create a new file containing the error notification object, for
example, tbx_diagerr.obj:, enter the following:
errnotify:
en_name = ″tbx_diagerr.obj″
en_persistenceflg = 1
en_label = ″HPS_DIAG_ERROR2_ER″
en_method = ″/<define_path>/methods/errnot.$1″
Note that the en_name value can have a maximum length of 16 characters.
Refer to the command odmshow errnotify to view the error notification
object.
4. Add the error notification object to the errnotify class:
odmadd /<define_path>/object/tbx_diagerr.obj
To delete this object, enter:
odmdelete -o errnotify -q ″en_name = tbx_diagerr.obj″
To view this object in the ODM database, enter:
odmget -q ″en_name = tbx_diagerr.obj″ errnotify
5. The following mail will be sent to root@controlworkstation when a switch
adapter fails diagnostics:
From root@sp21n12.aixedu.nl.ibm.com Fri Aug 10 11:29:03 1996
Received: from sp21n12.aixedu.nl.ibm.com by ppsras.aixedu.nl.ibm.com
(AIX 4.1/UCB 5.64/4.03)
id JT24554; Wed, 29 Mar 1996 15:30:42 -0400
Date: Fri, 10 Aug 1996 11:29:03 -0400
From: root
Message-Id: <9608101525.JT24554@sp21n12.aixedu.nl.ibm.com>
To: root
Status: RO
182
SP PD Guide
\
This soft copy for use by IBM employees only.
------------------------------------------------------------------------ERROR LABEL: HPS_DIAG_ERROR2_ER
ERROR ID: 323C48A0
Date/Time:
Sequence number:
Machine Id:
Node Id:
Error Class:
Error Type:
Resource Name:
Resource Class:
Resource Type:
Location:
Fri Aug 10 11:29:03
18282
000005911800
sp21n12
H
PERM
Worm
NONE
NONE
NONE
Error Description
HPS adapter failed Online diagnostics
Probable Causes
Switch clock signal missing
HPS adapter disconnected
User Causes
Switch cable disconnected
Recommended actions
Run adapter diagnostics
Failure Causes
HPS adapter
Recommended Actions
Run adapter diagnostics
Detail Data
DETECTING MODULE
LPP=PSSP,Fn=pubstest.ksh,SID=1.0,Func=main,
Service Request Number
Testing Error Notify
Keep the method scripts on each node so you can run them if network or
distributed file system problems occur. Using File Collections is an excellent
way to keep these scripts updated. The object files may be in a distributed file
system since they are not used unless changes to the object are required.
6.3.4 Mailing Error Reports to the Control Workstation
The following example shows how to mail the error report to
root@controlworkstation when an error of TYPE PEND occurs.
Adding the dsh -a command to the ODM commands will perform the action on all
nodes of the RS/6000 SP.
1. Set up the directories for the error notification objects and methods.
mkdir /<define_path>/errnotify/objects
mkdir /<define_path>/errnotify/methods
2. Create the error notification method script.
Create the script that will be run when the error occurs. For example:
Chapter 6. E r r o r Logging
183
This soft copy for use by IBM employees only.
#!/bin/ksh
#########################################################################
# Run errpt to get the full error report for the error that
#
# was written and redirect it to a unique errnot.$$ file.
#
# $$ will expand to the PID of this script.
#
#########################################################################
errpt -a -l $1 > /tmp/errnot.$$
#########################################################################
# Mail the full expanded error report to root@controlworkstation.
#
# This is the user and the hostname that the administrator wants
#
# to be notified at. They could be anywhere in the system.
#
#########################################################################
mail root@controlworkstation < /tmp/errnot.$$
3. Create the error notification objects.
Create the file that contains the error notification objects to catch the
pending availability problems.
Note that we have added some variations of PEND. This is because
uppercase PEND is not strictly adhered to by all AIX LPPs and vendors.
errnotify:
en_name = ″errnot.PEND.obj″
en_persistenceflg = 1
en_label = ″PEND″
en_method = ″/<define_path>/methods/errnot.$1″
errnotify:
en_name = ″errnot.Pend.obj″
en_persistenceflg = 1
en_label = ″Pend″
en_method = ″/<define_path>/methods/errnot.$1″
errnotify:
en_name = ″errnot.pend.obj″
en_persistenceflg = 1
en_label = ″pend″
en_method = ″/<define_path>/methods/errnot.$1″
4. Add the error notification objects to the errnotify class:
odmadd /<define_path>/object/errnot.pend.obj
To delete these objects, enter:
odmdelete -o errnotify -q ″en_name = errnot.PEND.obj″
odmdelete -o errnotify -q ″en_name = errnot.Pend.obj″
odmdelete -o errnotify -q ″en_name = errnot.pend.obj″
To view these objects in the ODM database, enter:
odmget -q ″en_name = errnot.PEND.obj″ errnotify
odmget -q ″en_name = errnot.Pend.obj″ errnotify
odmget -q ″en_name = errnot.pend.obj″ errnotify
5. Mail will be sent to the administrator at the Control Workstation when an
error of types PEND, Pend, or pend occurs.
184
SP PD Guide
This soft copy for use by IBM employees only.
6.3.5 Notification on Boot Device
The following example shows how to mail the error report to
root@controlworkstation when an error on the boot device of hdisk0 occurs.
Adding the dsh -a command to the ODM commands will perform the action on
all nodes of the RS/6000 SP.
1. Set up the directories for the error notification objects and methods:
mkdir /<define_path>/errnotify/objects
mkdir /<define_path>/errnotify/methods
2. Create the error notification method script.
Create the script that will be run when the error occurs. For example:
#!/bin/ksh
#########################################################################
# Run errpt to get the full error report for the error that
#
# was written and redirect it to a unique errnot.$$ file.
#
# $$ will expand to the PID of this script.
#
#########################################################################
errpt -a -l $1 > /tmp/errnot.$$
#########################################################################
# Mail the full expanded error report to root@controlworkstation.
#
# This is the user and the hostname that the administrator wants
#
# to be notified at. They could be anywhere in the system.
#
#########################################################################
mail root@controlworkstation < /tmp/errnot.$$
3. Create the error notification objects.
Create the file that contains the error notification object to catch the boot
disk error. In this example we assume that hdisk0 is the boot device:
errnotify:
en_name = ″errnot.boot.obj″
en_persistenceflg = 1
en_label = ″hdisk0″
en_method = ″/<define_path>/methods/errnot.$1″
4. Add the error notification object to the errnotify class:
odmadd /<define_path>/object/errnot.boot.obj
To delete this object, enter:
odmdelete -o errnotify -q ″en_name = errnot.boot.obj″
To view these objects in the ODM database, enter:
odmget -q ″en_name = errnot.boot.obj″ errnotify
5. Mail will be sent to the administrator at the Control Workstation when an
error on hdisk0 occurs.
Chapter 6. E r r o r Logging
185
This soft copy for use by IBM employees only.
6.3.6 Notification Power Loss and PANIC
The following example shows how to mail the error report to
root@controlworkstation when an unexpected power loss and kernel panic
occur.
Adding the dsh -a command to the ODM commands will perform the action on all
nodes of the RS/6000 SP.
1. Set up the directories for the error notification objects and methods:
mkdir /<define_path>/errnotify/objects
mkdir /<define_path>/errnotify/methods
2. Create the error notification method script.
Create the script that will be run when the error occurs. For example:
#!/bin/ksh
#########################################################################
# Run errpt to get the full error report for the error that
#
# was written and redirect it to a unique errnot.$$ file.
#
# $$ will expand to the PID of this script.
#
#########################################################################
errpt -a -l $1 > /tmp/errnot.$$
#########################################################################
# Mail the full expanded error report to root@controlworkstation.
#
# This is the user and the hostname that the administrator wants
#
# to be notified at. They could be anywhere in the system.
#
#########################################################################
mail root@controlworkstation < /tmp/errnot.$$
3. Create the error notification objects.
Create the file that contains the error notification objects to catch the kernel
panic and power loss error labels.
errnotify:
en_name = ″power.obj″
en_persistenceflg = 1
en_label = ″EPOW_SUS″
en_method = ″/<define_path>/methods/errnot.$1″
errnotify:
en_name = ″panic.obj″
en_persistenceflg = 1
en_label = ″KERNEL_PANIC″
en_method = ″/<define_path>/methods/errnot.$1″
errnotify:
en_name = ″DBL_PANIC.obj″
en_persistenceflg = 1
en_label = ″DOUBLE_PANIC″
en_method = ″/<define_path>/methods/errnot.$1″
4. Add the error notification object to the errnotify class:
odmadd /<define_path>/object/errnot.POWER.PANIC.obj
To delete these objects, enter:
186
SP PD Guide
This soft copy for use by IBM employees only.
odmdelete -o errnotify -q ″en_name = power.obj″
odmdelete -o errnotify -q ″en_name = panic.obj″
odmdelete -o errnotify -q ″en_name = dbl_panic.obj″
To view these objects in the ODM database, enter:
odmget -q ″en_name = power.obj″ errnotify
odmget -q ″en_name = panic.obj″ errnotify
odmget -q ″en_name = dbl_panic.obj″ errnotify
5. Mail will be sent to the administrator at the Control Workstation when any
power loss or kernel panic occurs.
6.4 Error Daemons
This section describes AIX error daemons and SP log daemons.
6.4.1 AIX Error Daemons
The error logging daemon errdemon reads error records from the special file
/dev/error and creates error log entries in the system error log. Each time an
error is logged, errdemon writes an entry in the system error log and performs
error notify as specified in the error notification database /etc/objrepos/errnotify.
The default system error log file is /var/adm/ras/errlog.
The last error log entry is always placed in NVRAM, and during system startup,
this last error entry is read from NVRAM and added to the error log when
errdemon is started.
errdemon does NOT create an error log entry for the logged error if the error
record template specifies Log=FALSE.
If you use errdemon without any flags, the system will use the values stored in
the error log configuration database for the error log file name, error log file size
and internal buffer size.
Note that you need root authority to run errdemon.
The file /var/adm/ras/errtmplt contains the error template repository.
The file /etc/objrepos/SWservAt (software service aids attributes object class)
contains the error log configuration database.
Flags
-i <file>
(lowercase i). Uses the error log file specified by the <file>
variable. The file name is saved in the error log
configuration database and is immediately put into use.
-l
(Lowercase L). Displays the values for the error log file
name, file size and buffer size from the error log
configuration database.
-s <logsize>
Uses the size specified by the <logsize> variable for the
maximum size of the error log file. The size limit is saved in
the error log configuration database and is immediately put
into use.
Chapter 6. E r r o r Logging
187
This soft copy for use by IBM employees only.
If the new size limit is smaller than the log file size currently
used, errdemon renames the current log file to <name>.old
and creates a new error log file with the specified size limit.
-B<buffsize>
Uses the number of bytes specified by the <buffsize>
parameter for the in-memory buffer used by the error log
device driver. The specified buffer size is saved in the error
log configuration database.
If the <buffsize> parameter is larger than the buffer size
currently in use, then the in-memory buffer will be
immediately increased.
If the <buffsize> parameter is smaller than the buffer size
currently in use, then the new size is put into effect the next
time errdemon is started after the system is rebooted.
The size you specify is always rounded up to the next
integral multiple of the memory page size (4KB). The
memory used for the error log device driver′s in-memory
buffer is not available for use by other processes (the buffer
is “pinned”).
Be careful not to impact your system′s performance by
making the buffer excessively large. On the other hand, if
you make the buffer too small, the buffer can become full if
error entries arrive faster than they can be read from the
buffer and put into the log file. When the buffer is full, new
entries are discarded until space becomes available in the
buffer. When this situation occurs, errdemon creates an
error log entry to inform you about the problem. You can
easily correct this problem by enlarging the buffer.
Note: On the RS/6000 SP system, thin and wide nodes behave differently
regarding NVRAM and power loss.
You can use the command errclear to remove entries from the system error
log.
Note that errdemon is normally started during system initialization. Stopping the
error logging daemon can cause error data to be temporarily stored in internal
buffers. These buffers can be overwritten before the error data is recorded in
the error log file.
If you have specified a new error log file size and you want to generate an error
report from the old one, you can use the -i option of the errpt command.
Note that the buffer cannot be made smaller than the hard-coded default of 8 KB.
Syslogd Daemon
The syslogd daemon reads a datagram socket and sends each message line to
a destination described by the /etc/syslog.conf configuration file. The syslogd
daemon reads the configuration file when it is activated and when it receives a
hangup signal.
The syslogd daemon creates the /etc/syslog.pid file, which contains a single line
with the command process ID used to end or configure the syslogd daemon. A
terminate signal sent to the syslogd daemon ends the daemon, and syslogd will
188
SP PD Guide
This soft copy for use by IBM employees only.
log the end-signal information and terminate immediately. Each message is one
line. A message can contain a priority code, marked by a digit enclosed in <>
(angle braces) at the beginning of the line.
Configuration File
The configuration file informs the syslogd daemon where to send a message,
depending on the message′s priority level and facility. The syslogd daemon
ignores blank lines and lines beginning with a # (pound sign).
Lines in the configuration file for the syslogd daemon contain a selector field and
an action field, separated by one or more tabs. The selector field names a
facility and a priority level. You can separate facility names with a comma (,)
and separate the facility and priority-level portions of the selector field with a
period (.). You can separate multiple entries in the same selector field with a
semicolon (;). To select all facilities, you can use an asterisk (*).
The action field identifies a destination (file, host, user) to receive a message. If
routed to a remote host, the remote system will handle the message as
indicated in its own configuration file. To display messages on a user′s terminal,
the destination field must contain the name of a valid, logged-in user.
See Table 7 on page 190 for field definitions and uses.
Chapter 6. E r r o r Logging
189
This soft copy for use by IBM employees only.
Facility Names
kern
user
mail
daemon
auth
syslog
lpr
news
uucp
*
Kernel
User Level
Mail subsystem
System daemons
Security or authorization
syslogd daemon
Line-printer subsystem
News subsystem
uucp subsystem
All facilities
emerg
LOG_EMERG. Emergency (or
panic) messages, for
example, disk errors.
Emergency/panic errors are
not distributed to all users.
LOG_ALERT. Important
messages such as a serious
hardware error. These
messages are distributed to
all users.
LOG_CRIT Critical messages
not classified as errors, for
example, improper login
attempts. LOG_CRIT and
higher-priority messages
are sent to the system
console.
LOG_ERR. Represents an
error condition, for example,
an unsuccessful disk write.
LOG_WARNING. Messages for
abnormal, but recoverable
conditions.
LOG_NOTICE. Important
informational message. All
messages without a priority
are mapped to this priority.
LOG_INFO. Informational
messages. Normally you
can discard these
messages, but they can be
useful in analyzing the
system.
LOG_DEBUG. Debugging
messages. You can discard
these messages.
Excludes the selected
facility. This priority level is
useful only if preceded by
an entry with an * (asterisk)
in the same selector field.
alert
crit
Selector Field
err
Priority Levels
warning
notice
info
debug
none
File name
Action Field
Destination
@host
User,user
*
Table 7. Configuration File Field Definitions
190
SP PD Guide
Full path name of a file
opened in append mode
Host name, preceded by @
(at sign)
User name(s)
All users
This soft copy for use by IBM employees only.
6.4.2 SP Log Daemons
setup_logd sets up the SP logging daemon (splogd) and is called by installation
scripts when the Control Workstation is installed. It can also be run by root on a
different workstation to have splogd spawned by the SCR (System Resource
Controller).
If you want to run the splogd logging daemon on a workstation other than the
Control Workstation, you must install the ssp.clients option on that workstation
and run setup_logd. Do this in the following order:
1. Off-load error logging from the Control Workstation.
2. Have your own script called when a state on a particular variable or
variables occurs.
By default, the /spdata/sys1/spmon/hwevents file is set up to do error logging
and state change logging for all frames. If you are installing splogd on a
workstation besides the Control Workstation in order to call your own script, you
must edit the /spdata/sys1/spmon/hwevents file and remove the entries for
SP_STATE_LOG and SP_ERROR_LOG. You must also add a call for your own
script. If you do not want to perform any of the following steps on your
workstation, do not run setup_logd.
The setup_logd command performs the following steps:
1. It creates directories in /var/adm that the logging daemon uses. (Of course
this will only be done if they do not already exist.)
2. It adds an entry to the file /etc/syslog.conf for the daemon.notice and sends
a HUP signal to syslogd to reread its configuration file.
3. It adds errlog templates for SP messages.
4. It adds the splogd daemon to SRC as the splogd subsystem.
5. It adds an entry for splogd to /etc/inittab.
Important
If you are only using syslogd to call your own script, perform only Step 4 and
Step 5: add syslogd to SRC and add an entry to /etc/inittab.
If you want to run the logging daemon on a separate workstation, you must add
(or change) the following line to the /etc/environment file:
SP_NAME=<Control Workstation>
If you want to move a subset of error logging off the Control Workstation, you
must edit /spdata/sys1/spmon/hwevents on the Control Workstation and define
the new subset that you want to monitor. Then issue stopsrc command to stop
the logging daemon on the Control Workstation, and issue startscr reread the
hwevents file at start time.
The SP logging daemon splogd has the following functions:
error logging
Reports the SP hardware errors to both the syslog and the
AIX error log.
state change logging Writes SP hardware state changes to a file.
user exits
Calls a user exit when a state change occurs.
Chapter 6. E r r o r Logging
191
This soft copy for use by IBM employees only.
The hwevents file contains state change actions that are to be performed by the
splogd logging daemon. The fields in this file are:
frame
Specifies the frame number (1- n ) or * (asterisk) for all
frames.
slot
Specifies the following:
•
A number from 0-17
•
One of
−
−
−
−
−
−
−
NODES_ONLY (addresses 1 through 16)
SWITCH (address 17)
FRAME (address 0)
* (asterisk, all addresses)
NODES_AND_SWITCH (addresses 1-17)
FRAME_AND_NODES (addresses 0-16)
FRAME_AND_SWITCH (addresses 0 and-17)
variable
Specifies a hardware variable. For example, nodePower,
Temp, LED7SegA.
operator
Specifies how to compare the value. Acceptable values
are: =, <, > and !=.
value
Specifies the value of the variable to match the operator
wildcard (*) or a partial match with the wildcard at the end
(23*).
time
Specifies if the function should be called at startup or
when the state changes, or both times. Valid options are
startup, change or both.
function
Specifies the program to call when the event occurs.
There two special keywords for function If function is
SP_ERROR_LOG, error logging is performed provided that
syslog is set up and AIX error logging is set up to perform
SP logging. Refer to the setup_logd.
If function is SP_STATE_LOG, these state changes that
meet the statement′s criteria are logged to the file
/var/adm/SPlogs/spmon/splogd.state_changes.<timestamp>.
Note that you must send a SIGHUP signal to splogd to close the current
state_changes.<timestamp> and to open a new one. For example:
kill -HUP <splogd_PID>
User Exit Arguments
When a user exit is called by splogd, the following arguments are passed:
1. A c or s depending on whether this call is for a change of state or to
provide the startup values for the variables being monitored.
2. For each variable being reported, the following arguments are passed:
•
•
•
•
192
SP PD Guide
Frame number
Node number
Variable name
Value of the variable. (Boolean values are expressed as TRUE or FALSE,
integers as decimal strings, and floating-point values as floating-point
strings.)
This soft copy for use by IBM employees only.
Starting and Stopping the splogd Daemon
The splogd daemon is under System Resource Controller (SRC) control. It uses
the signal method of communication in the SRC. The splogd daemon is a single
subsystem and not associated with any SCR group. The subsystem name is
splogd.
In order to start the splogd daemon, use the startsrc -s splogd command. This
command starts the daemon with the default arguments and SRC options. The
splogd daemon is set up to be respawnable and to be the only instance of the
splogd daemon running on that particular node or Control Workstation.
Important
Do not start splogd from the command line without using the startsrc
command to start it.
To stop the splogd daemon, you can use the command stopsrc -s splogd. This
will stop the daemon and does not allow it to respawn.
To display the status of the splogd daemon, issue the command lsscr -s splogd.
You can view the current SRC options and daemon arguments with the
command:
odmget -q ″subsysname=splogd″ SRCsubsys
You can change the default startup arguments with the command chssys.
Chapter 6. E r r o r Logging
193
This soft copy for use by IBM employees only.
194
SP PD Guide
This soft copy for use by IBM employees only.
Chapter 7. Isolating Problems on the SP System
Most of the problems covered in previous chapters can be grouped into four
main categories. Each of those categories has different types of errors.
This chapter provides some reference material, in flowcharts and in overviews,
that gives pointers on how to resolve SP problems in those categories. These
flowcharts and overview charts are not complete; they only present well-known
problems and some hints that can help to identify a problem.
7.1 Isolating Booting Problems
The following sections discuss network booting considerations and problems.
7.1.1 Booting Process Overview
In order to network boot and install nodes, they must be defined as NIM clients
for the NIM master (in NIM jargon), or boot/install server (in SP jargon). When
they are defined, the NIM master allocates the necessary resources for them to
boot and install.
The NIM database contains the NIM objects that define clients and resources,
along with attributes and states for those objects. When setup_server is run,
after set the boot_responds to install or customize for the affected nodes, this
script executes several NIM commands for allocating resources to each client.
Figure 76. Booting Process Overview
The most visible and easily-checked results that happen when resources have
been allocated to clients to boot and install are the /etc/bootptab file and the
 Copyright IBM Corp. 1996
195
This soft copy for use by IBM employees only.
/etc/tftpboot directory. They keep the information and resources to network boot
or customize the nodes.
More information about this process and what files are created, can be found in
Chapter 2, “The Installation Process” on page 7.
7.1.2 Booting Problems
Figure 77. Booting Problems
The booting process has several components that work together to accomplish
the tasks of network booting, installing, and customizing a node. During the first
steps of this process, you have to specify who will serve the nodes you want to
install. Along with that, you set the boot responds to install or customize in the
SDR. Finally, you run setup_server. This script executes several NIM
commands to allocate the necessary NIM resources to each client. Note that if
you are installing several nodes with several NIM masters, setup_server will run
in each one of the NIM masters that will be part of this installation or
customization.
If you encounter problems running setup_server, look at 2.9.2, “Setup_server
Fails” on page 56, which covers those kinds of problems. However, after
running setup_server successfully, you are about to start the booting process.
To start installing or customizing your nodes, you must reboot them or power
them on, if they were powered off. When they start booting, you will see the LED
in the panel display.
The LED numbers are very useful to determine which step is being executed. In
the chart, you see LED numbers indicating where nodes usually get stuck, for
several reasons.
196
SP PD Guide
This soft copy for use by IBM employees only.
LED 260-262
These numbers indicate that the node is displaying the boot menu
but there must be something wrong with the serial link, because
nodecond cannot get messages from there.
LED 231-239
This is a booting problem. The node is intending to boot from the
network, but no one is responding. It could be that the inetd is not
responding, or the bootp or tftp daemons are not responding.
Also, it can be a NIM problem, or an inconsistency between NIM
and the SDR.
LED 610-612
This means that the node was unable to mount a remote resource
using NFS. It is difficult to determine which resource mount failed.
•
On the NIM master, verify that NFS is functioning correctly and
that the appropriate resources have been exported correctly.
•
If you have a gateway between the NIM client and NIM server,
verify that the route defined in the NIM configuration is correct.
If you do not find any of the problems mentioned above, a good solution would
be reset the NIM client and start all over again.
The final step of the installation process is customization. This is done by the
pssp_script script. Many problems can be found if you look at the console log
file for the particular node.
7.2 Isolating System Monitor Problems
The following section discusses how to isolate system monitor problems.
Figure 78. System Monitor Problems
Chapter 7. Isolating Problems on the SP System
197
This soft copy for use by IBM employees only.
Problems with System Monitor GUI
•
spmon command fails to start the System Monitor GUI. Then check the
following:
−
Verify authorization
- Run klist command to verify that kerberos tickets have not expired.
Important
spmon will not run if kerberos tickets never expire.
- Re-issue kinit command, if required.
- Check the /spdata/sys1/spmon/hmacls file to ensure that the
kerberos principal name and instance for your ID is in this hardware
monitor ACL file.
sp2cw0 root.admin a
sp2cw0 hardmon.sp2cw0 a
1 root.admin vsm
1 hardmon.sp2cw0 vsm
−
Ensure you have exported the DISPLAY variable:
# echo $DISPLAY
<hoatname or IP address>:0
•
If the open session failure message window is displayed after opening the
System Monitor GUI, then verify authorization using klist and request
authorization using the kinit command. If the problem persists, check the
/spdata/sys1/spmon/hmacls file.
Hardware monitor daemon (hardmon) is not running
•
Execute the following command to verify that the hardmon daemon is
functioning correctly:
# hmmon -Q 1:1
•
If the above command does not work, check the hardmon log file at
/var/adm/SPlogs/spmon/hmlogfile.xxx, where xxx is the creation date.
Logging problems
•
Logfile is no longer being updated
Check the logging daemon
−
Check that splogd is running
The following example shows how you can check that the splogd is
running:
# lssrc -a  grep splogd
splogd
15378
active
or,
# ps -eaf  grep splogd
root 15378 5854 0 May 08 - 0:00 /usr/lpp/ssp/bin/splogd
-f /spdata/sys1/spmon/hwevents
root 18408 15248 0 11:22:43 pts/0 0:00 grep splogd
198
SP PD Guide
This soft copy for use by IBM employees only.
−
Check that the following entry is in the /etc/syslog.conf configuration file:
daemon.notice
/var/adm/SPlogs/SPdaemon.log
−
Check that the /var/adm/SPlogs/SPdaemon.log file has the correct
permissions (rw-r--r--).
−
Check that the error record templates for SPMON exists:
# errpt -t | grep SPMON
7.3 Isolating Switch Problems
Figure 79. Switch Problems
The SP switch problems are usually related to four main components:
•
Estart
This command is executed when you want to start the switch. However this
command is not the real one; the real one resides in the primary node and is
called Estart_sw. Chapter 4, “The Switch” on page 87 describes all the
tasks accomplished by these commands, so you can check there if you face
problems related to them.
•
Switch Processes
These processes must be running in all the nodes participating in the switch
network. So, always check that those processes are running in each node.
The rc.switch script starts those processes and it can be executed multiple
times if necessary.
•
Topology and clock files
Chapter 7. Isolating Problems on the SP System
199
This soft copy for use by IBM employees only.
These files define how the nodes will communicate. The topology files
define the links between nodes, and the clock files define how the clock is
sourced into each switch board and adapter. If your topology or clock file is
wrong, you will not be able to use the switch. Always check that the SDR
contains the right files.
•
Hardware
Because the switch is a very stable SP component, hardware problems are
in the common sources of switch-related problems.
7.4 Isolating System Partitioning Problems
As we discussed in Chapter 6, “Error Logging” on page 159, many PSSP
components get partitioned when a system partition is applied. Nevertheless,
many components remain systemwide.
Figure 80. System Partitioning Problems
System partitioning problems usually arise from two sides:
•
Problems applying system partitions
There several ways to recover a failed system partition apply. These ways
usually consist of recovering the SDR (previously saved). If that fails, you
still have a chance to recover your system by executing some SDR
commands that were described in Chapter 5, “System Partitioning” on
page 125.
•
Problems accessing partitions
Usually these problems are related to missing topology files or problems
with the SDR. Remember that several SP components also get partitioned
when you apply a system partition, so be careful to check that your
commands are querying to the right set of daemons.
200
SP PD Guide
This soft copy for use by IBM employees only.
Chapter 8. Producing a System Dump
There is not much difference in the way system dumps are handled in an SP
environment. The only exception to this is in the primary dump device used by
the nodes when they are running AIX Version 4.1.
•
•
In AIX Version 3.2.5, the default dump device was /dev/hd7/, a special device
for system dumping.
With AIX Version 4.1, the primary dump device was changed to /dev/hd6,
which is the default paging space.
This way, you will not need a special device with additional disk space to
copy a system dump when this is generated.
However, in the SP nodes, the special device /dev/hd7/ is still used, even when
the nodes are running AIX Version 4.1, because the nodes do not have a console
directly attached, and after a system dump is generated, the system intends to
copy it to the /var/adm/ras directory.
Therefore, when you are using the paging space, this system dump must be
copied; otherwise it will get lost when the system starts.
If you do not have space on the /var file system, the system will display a menu
on the console asking for an answer about what to do with the system dump.
This will cause your node to hang while it waits for an answer from the serial
link.
This chapter gives a brief overview of system dumps and provides examples
with commands and scripts you can use to handle them.
8.1 Handling Systems Dumps
The system generates a system dump when a severe error occurs. System
dumps can also be user-initiated by users with root authority. A system dump
creates a picture of your system′s memory contents. System administrators and
programmers can generate a dump and analyze its contents when debugging
new applications.
When the system halts with a flashing 888 followed by a 102, then you know that
a system dump has occurred. When this happens, you must reboot the system
in order to get the system back again.
There are two types of system dumps.
System-initiated
User-initiated
Produced if a kernel panic occurs.
Generated by a command or by using the key lock and the
reset button.
A system-initiated dump is a snapshot of the kernel. A system dump occurs
when a kernel panic takes place. This dump includes selected kernel structures,
as specified in the dump table. The dump table is a kernel structure containing
a list of structures that have been loaded, such as device drivers and program
code. This table is dynamic, so there is definite rule as to how large the dump
will be. The dump does not include paged memory.
 Copyright IBM Corp. 1996
201
This soft copy for use by IBM employees only.
Following are some of the kernel structures that are captured by the system
dump:
System Variables and Statistic
This comprises the kernel parameters either set by
the user or hardcoded into the kernel. Such statistics
include maxuproc (maximum number of processes
per user), fsize (maximum file size), and stack
(maximum stack segment size).
Process Table
The process table contains a list of all currently
running processes and relevant information about
those processes.
User Areas
This includes more information about the current
running processes on the system. It includes the file
descriptor table.
VFS Information
This includes information about currently mounted
file systems, the inode table and the open file table.
Kernel Stack
The kernel stack keeps the track of all the processes
that were running in kernel mode at that time.
System Buffers
This is the area where incoming data is stored while
awaiting memory allocation from the kernel.
TTY information
Contains information about currently configured ttys,
their characteristics, and current state (including line
discipline).
Mbufs
These are the memory buffers for data which have
been sent/received across the network.
Sockets
A socket is a logical device which can be described
as the end of a pipeline by which network data is
transmitted.
When an unexpected system halt occurs, the system dump facility automatically
copies selected areas of the kernel data to the primary dump device. These
areas include kernel segment 0 as well as other areas registered in the master
dump table by kernel modules or kernel extensions. Memory-resident user data
is also dumped.
AIX version 4 maintains two system dump devices:
Primary
Usually used when you wish to save the dump data.
Secondary Can be used to discard dump data (for example, /dev/sysdumpnull).
202
SP PD Guide
This soft copy for use by IBM employees only.
Make sure you know your system and know what your primary and secondary
dump devices are set to.
•
To list the current dump destination:
# sysdumpdev -l
primary
secondary
copy directory
forced copy flag
always allow dump
•
/dev/hd6
/dev/sysdumpnull
/var/adm/ras
TRUE
FALSE
To set the dump device:
# sysdumpdev [-P]
{-p|-s} <device>
Dump devices are usually portable mediums such as tape drives. However, for
the SP nodes, those tape drives are not attached directly. You may copy the
content of the dump into a file, then transfer it to the Control Workstation, and
then download it to a tape.
A dump device can be configured either as a dedicated device that requires no
operator intervention when a dump occurs, or as a shared device that can be
used for other purposes until a dump is requested. A dedicated dump device is
referred to as the primary dump device, and a shared one as a secondary dump
device.
Operator intervention is required when a dump is to be written to the secondary
dump device. When you install the operating system, the dump device is
automatically configured for you. By default the primary device is /dev/hd6,
which is a paging logical volume, and the secondary device is /dev/sysdumpnull.
Note that for systems which have been migrated from AIX Version 3.2.5 to AIX
Version 4.1, the primary dump device is set to what it was formerly /dev/hd7.
Important
/dev/hd7 is the primary dump device by default on the SP nodes, even in
version 4.1. The reason for this is simple: Because /dev/hd6 is the paging
space, after a system dump the node comes back and waits in the S1 line for
a response about what to do with the system dump that resides in its paging
space.
Use the sysdumpdev command or SMIT to query or change the primary and
secondary dump devices.
•
To estimate the size of the dump for the current system:
# sysdumpdev -e
estimated dump size in bytes: 16250880
•
To display statistical information about the previous dump:
# sysdumpdev -L
Flags:
-l
List
-p
Primary
-s
Secondary
Chapter 8. Producing a System Dump
203
This soft copy for use by IBM employees only.
-P
Make change permanent
-d directory
Specifies the directory where the dump is copied at boot time. If
the copy fails, the system continues to boot.
-D directory
Specifies the directory where the dump device is copied at boot
time. If the copy fails, then a menu is displayed to allow the user
to copy the dump.
-z
Writes out to standard output the string containing the size of the
dump in bytes and the name of the dump device, if a new dump
is present.
AIX version 4 uses /dev/hd6 (paging) as the default dump device unless the
system was migrated from AIX version 3, in which case it will continue to use
the AIX version 3 dump device /dev/hd7.
Important
The previous paragraph does not apply for the SP nodes, which use /dev/hd7
as the default primary dump device.
If a dump occurs to paging, the system will automatically copy the dump when
the system is rebooted. By default, the dump gets copied to the /var/adm/ras
directory.
The recommended value is that the dump device is at least a quarter of the size
of real memory. In such situations, it is advisable to create a temporary dump
logical volume of the size required and manually recreate the environment in
which the dump occurred. If the dump device is not large enough, the system
will produce a partial dump only. It is possible, but extremely unlikely, that a
Support Center can determine the cause of the crash from a partial dump. The
-e flag can be used as a starting point to determine how big the dump device
should be.
8.1.1 How to Start a Dump
There are three ways for a user to invoke a system dump, but only two are valid
on the SP nodes, since keyboard input is not possible. Which method is used
depends on the condition of the system.
If there is a kernel panic, the system will automatically dump the contents of real
memory to the primary dump device.
The user/administrator can initiate a system dump at any time by pressing the
reset button (using spmon or GUI) while the keylock position is set to service
mode.
Bear in mind that if your system is still operational, a dump taken at this time
will not assist in problem determination. A relevant dump is one taken at the
time of the system halt.
Do not start a dump if the flashing 888 number shows on the LED. This number
could indicate that a dump has already occurred on your system. (You can
determine this by finding out the LED code that is displayed after the flashing
888. If it is a 102, then this indicates that a dump has occurred). This indicates
that your system has already created a system dump and has written the
204
SP PD Guide
This soft copy for use by IBM employees only.
information to the primary dump device. If you start your own dump before
copying the information in your dump device, your new dump will overwrite the
existing information.
A user-initiated dump is different from a dump initiated by an unexpected system
halt because the user can designate which dump device to use. When the
system halts unexpectedly, a system dump is initiated automatically to the
primary dump device.
You can start a dump using one of the following methods:
•
Command Line
This method uses the sysdumpstart command. Note, however, this command
is only available if you install the Software Service Aids
(bos.sysmgt.serv_aid) package.
You must have root authority to run this command. First you might want to
check the current settings of your system dump devices by using the
sysdumpdev -l command. Then initiate the dump with sysdumpstart -p (for
primary device) or -s (for secondary device). Note that if the LED display is
blank, the dump was not started. Try again using a different method.
•
Using SMIT
You can use the fast path: smity dump.
•
Using special key sequence
This option is only valid for the Control Workstation. You can initiate a
dump, either to the primary or secondary dump device, by using the
following key sequence:
<crtl-alt-NUMPAD1>
•
Using the reset button
This procedure works for all system configurations and will work in
circumstances where other methods for starting a dump will not. Turn the
key into service position and press the reset button once. The system writes
the dump information to the primary dump device.
If a system dump is initiated by kernel panic, the LEDs will display 0c9 while the
dump is in progress, and then flash 888. Using the reset button to rotate through
the other LED codes, you will eventually encounter one of the codes shown in
the foil. The code you want is 0c0, indicating that the dump completed
successfully. All of the LED codes following the flashing 888 should be recorded.
For user-initiated system dumps to the primary dump device, the LED codes
should indicate 0c2 for a short period, followed by 0c0 upon completion.
Other common codes include:
0c4
This indicates that the dump routine ran out of space on the specified
dump device. It may still be possible to examine and use the data on
the dump device, but this tells you that you should increase the size
of your dump device.
0c5
This indicates you should check the availability of the medium to
which you are writing the dump.
Chapter 8. Producing a System Dump
205
This soft copy for use by IBM employees only.
0c7
This indicates a network dump is in progress, and the host is waiting
for the server to respond. The value in the three-digit display should
alternate between 0c7 and 0c2 or 0c9 . If the value does not change,
then the dump did not complete due to an unexpected error.
0c8
This indicates you have not defined a primary or secondary dump
device. The system dump option is not available. Enter the
sysdumpdev command to configure the dump device.
0c9
This indicates a dump started by the system did not complete. Wait
for one minute for the dump to complete and for the three-digit
display to change. If the three-digit display value changes, find the
new value on the list. If the value does not change, then the dump
did not complete due to an unexpected error.
8.1.2 Copying a System Dump
The following section discusses details of copying a system dump.
Figure 81. Copying a System Dump
After a crash, if the LED displays 0c0, then you know that a dump occurred and it
completed successfully. Press the reset button once. If there is enough space
to copy the dump from paging to the /var/adm/ras directory, then it will be
copied directly. If, however, at bootup the system determines that there is not
enough space to copy the dump to /var, the /sbin/rc.boot script (which is
executed at bootup) will call on the /lib/boot/srvboot script. This script in turn
calls on the copydumpmenu command, which is responsible for displaying the
following menu which can be used to copy the dump to removable media.
206
SP PD Guide
This soft copy for use by IBM employees only.
Copy a System Dump to Removable Media
The system dump is 16957952 bytes and will be copied from /dev/hd6
to media inserted into the device from the list below.
Please make sure that you have sufficient blank, formatted
media before you continue.
Step One:
Step Two:
Insert blank media into the chosen device.
Type the number for that device and press Enter.
Device Type
Path Name
>>>
88
99
Help ?
Previous Menu
>>> Choice[0]:
Note: You will need to attach an external device to the SP nodes in order to use
this option.
To copy a system dump after rebooting in normal mode, do the following:
•
If it is the Control Workstation, log in as root and copy the system dump to
either diskette or tape using snap command:
# /usr/sbin/snap -gfkD -o /dev/rfd0
(The example shown copies the dump to diskette)
If the dump went to the paging space logical volume, it has been copied to
the directory /var/adm/ras in rootvg. These dumps are also copied by the
snap command.
•
If it is a node, you may use the following procedure:
Chapter 8. Producing a System Dump
207
This soft copy for use by IBM employees only.
#!/usr/bin/ksh
#
# Usage: mkdump [filename] [block size]
#
# Description:
#
Copy the system dump from the primary dump device to
#
file name (/var/adm/ras/dump_file by default) using the
#
block size specified (4096 by default).
#
dev=sysdumpdev -l|awk ′ / primary/ {print $2}′
size=sysdumpdev -L|awk ′ / Size/ {print $2}′
dir=sysdumpdev -l|awk ′ / directory/ {print $3}′
bs=${2:-4096}
file=${1:-dump_file}
count=expr $size / $bs
OVFL=expr $size % $bs
if • $OVFL != 0 “
then
count=expr $count + 1
fi
echo “Copying from $dev to $file $size bytes...”
echo “....please wait....”
dd if=$dev of=$dir/$file bs=$bs count=$count
8.1.3 Sending the Dump to the Support Center
If a system halt occurs once, there is probably little point in sending the dump
for analysis. However, if the system is halting repeatedly and this is seriously
impacting the use of the machine, the dump can be sent to the Support Center
(through your normal first-level support channel) for analysis.
The Support Center will analyze the contents of the dump using the crash
command. The crash command uses the kernel that was active on the system at
the time of the halt. Therefore, /unix should be sent from the machine where the
dump was produced.
The AIX command snap was developed by the support team in Austin to simplify
gathering configuration information. It provides a convenient method of sending
the lslpp and errpt output to the Support Center. It gathers system configuration
information and compresses the information to a tar file. The file can then be
downloaded to disk, or tape.
Some useful flags with the snap command are:
208
SP PD Guide
-f
Gather file system information
-g
Gather general information
-k
Gather kernel information
-D
Gather dump and /unix
This soft copy for use by IBM employees only.
The information gathered with the snap command can be used to identify and
resolve system problems. You must have root authority to execute this
command.
If you use the -a flag, then you need approximately 8 MB of temporary disk
space to collect all the system information, including the content of the error log.
The -g flag gathers the following information:
•
Error report
•
Copy of the customized ODM
•
Trace file
•
User environment
•
Amount of physical memory and paging space
•
Devices and attribute information
•
Security user information
The output from the -g flag is written to /tmp/ibmsupt/general/general.snapfile.
However, you can specify another directory using the -d flag.
The execution of the snap appends information to the previously-created files.
Use the -r flag to remove previously-gathered and saved information.
Before you send your media to the Support Center, make sure you contact the
Center and obtain a Problem Management Number (PMR) which will be used to
trace the status of your problem from then on. Make sure you label the media
with this number and also the other pieces of information listed, to help the
support team act quickly on your problem.
There is not much left for you to do after this, apart from waiting for a response
from the Support Center. However, you may want to look at your dump to try to
analyze it yourself. The tool that is used by the Support Center to analyze your
dump is called crash which also is available on the system. However, the output
from the command is very user-unfriendly, and most people do not bother to
analyze it. However, the following section describes how to use crash to analyze
a system dump.
Chapter 8. Producing a System Dump
209
This soft copy for use by IBM employees only.
8.1.4 Using crash to Analyze a Dump
Figure 82. Using crash
The dump can be analyzed by using the crash command. The crash command
can be used to check the validity of the dump:
# crash /var/adm/ras/vmcore.x /unix
If the following appears on the screen, then the dump is good:
Reading in symbols
>
If the copy of /unix does not match the dump file, the following output will appear
on the screen:
WARNING: dump file does not appear to match namelist
Reading in symbols
>
If the dump itself is corrupted in some way, then the following will appear on the
screen:
0452-179 Cannot read vstructure from address
>
To exit the crash debug program, type quit at the > prompt.
From the > prompt, you can enter a number of crash subcommands. The
following example shows typical values that might be seen.
The crash command and subcommands are fully documented in InfoExplorer, but
the following shows basic examples of the use of crash subcommands:
210
SP PD Guide
This soft copy for use by IBM employees only.
> stat (to show machine status at
sysname: AIX
nodename: sp21n02
release: 1
version: 4
machine: 000168205700
time of crash: Tue Aug 6
age of system: 7hr, 22min
abend code: 0
csa: 0x0
> status
CPU
TID TSLOT
PID PSLOT
0
2b43
43
2e3a
46
time of crash)
15:38:38 1996
PROC_NAME
sysdumpstart
The status subcommand displays a description of the kernel process. The
information includes CPU number, thread ID, thread table slot, process ID,
process table slot and process name. In our example, sysdumpstart is in
process slot 46. To see further information about this process:
> p -r
SLT ST
2 a
PID PPID PGRP UID EUID TCNT NAME
204
0
0
0
0
1 wait
FLAGS: swapped_in no_swap fixed_pri kproc
26 a
1aee 2da4 1aee
0
0
1 find
FLAGS: swapped_in
46 a
2e3a 2da4 2e3a
0
0
1 sysdumpstart
FLAGS: swapped_in
0452-1004: Cannot read process table entry 37.
(Ignore messages reading “cannot read process table entry.”)
This shows that the process running at the time of the crash was sysdumpstart
and it was running in slot 46. It also shows find was running in slot 26. To see
the stack trace for find:
> t 26
STACK TRACE:
.et_wait()
.poll_wait()
.select()
.sys_call()
The crash command is an interactive utility for examining an operating system
image, a core image, or the running kernel. It also interprets and formats
control structures in the system and certain miscellaneous functions for
examining a dump.
In order to analyze the dump, you must execute the crash command against
/unix, and it must be the /unix of the system that had the problem. However, to
make any change to code, you must have the source AIX code which is not held
by customers. Therefore, there is not much more that you can do. It is best to
let the Support Center handle the dump.
One useful operation you can do is to make sure that you have a good full dump.
If you see :
Reading in symbols
>
Chapter 8. Producing a System Dump
211
This soft copy for use by IBM employees only.
after executing the crash command, you know that you have a full dump that can
be analyzed. You should avoid sending dumps to the Support Center, only to
find out that the Center cannot do anything about them because they are partial
dumps. Get it right from the start.
212
SP PD Guide
This soft copy for use by IBM employees only.
Chapter 9. User and Services Management
This redbook is not intended to cover system management issues. The problem
determination procedures described in this book are related to basic PSSP
components, and are mainly operational tasks performed by the system
administrator.
User and Services Management tasks are covered in other publications.
This chapter gives basic hints as to how to deal with certain problems related to
SP system management.
9.1 Overview
The PSSP 2.1 software provides a single point of control for administrative tasks.
9.1.1 User Accounts
SP User Management allows you to add, delete, change, and list user account
information from a single point of control. Users can have the same account,
home directory, and environment across all the nodes in the system.
9.1.2 File Collections
Groups of files can be defined as a file collection and changes to any files in that
collection can be propagated to all nodes. The user.admin file collection is
provided for propagating user administration files to the nodes on the system.
9.1.3 Auto Mount Daemon (Amd)
Amd allows filesystems to be mounted on demand when they are first
referenced and then be umounted after a specific period of inactivity. SP User
Management uses Amd to automount a user′s home directory when the user
performs a login on a node.
9.1.4 Print Services
SP User Management provides the ability to shift printing functions from the
nodes to a print server, eliminating the need to maintain and support print
queues on a large number of nodes.
9.1.5 Network Time Protocol (NTP)
The RS/6000 SP system uses NTP to synchronize the time-of-day clocks on the
Control Workstation and the nodes.
In the following sections of this chapter, the assumption is made that the user
has chosen to implement SP User Management together with file collections and
the auto mount daemon.
 Copyright IBM Corp. 1996
213
This soft copy for use by IBM employees only.
9.2 Components
The following options of the ssp installp image are relevant to User and Services
Management. Component version numbers included are for PTF 11.
9.2.1 ssp.basic 2.1.0.10
This component includes the login control functions whereby users can either be
allowed or denied access to specific nodes.
9.2.2 ssp.sysman 2.1.0.7
This component includes the following functions:
•
User management
•
File collections
•
Auto Mount Daemon
•
Print support
•
Time services
9.3 Managing User Accounts
In order to have the SP User Management tools added to the System
Management Interface Tool (SMIT) panels, specify “true” in the User
Administration Interface field of the Site Environment Information panel of SMIT.
To make use of the various services (file collections, Amd, print services, and
NTP), specify “true” in the appropriate fields of the same SMIT panel.
214
SP PD Guide
This soft copy for use by IBM employees only.
Site Environment Information
Type or select values in entry fields.
Press Enter AFTER making all desired changes.
[TOP]
Default Network Install Image
Remove Install Image after Installs
NTP Installation
NTP Server Hostname(s)
NTP Version
AMD Configuration
[Entry Fields]
[bos.obj.ssp.41]
false
consensus
[″ ″ ]
3
true
Print Management Configuration
Print system secure mode login name
false
[″ ″ ]
User Administration Interface
Password File Server Hostname
Password File
Home Directory Server Hostname
Home Directory Path
true
[sp21cw0]
[/etc/passwd]
[sp21cw0]
[/home/sp21cw0]
File Collection Management
File Collection daemon uid
File Collection daemon port
true
[102]
[8431]
SP Accounting Enabled
SP Accounting Active Node Threshold
SP Exclusive Use Accounting Enabled
Accounting Master
false
[80]
false
[0]
Figure 83. Default Values for the Site Environment Information Panel
These configuration values are stored in the System Data Repository and are
used as default values when managing SP user accounts with the spmkuser,
spchuser, and sprmuser commands. Use the splstdata -e command to list the
current values of the SP object attributes from the System Data Repository. See
Figure 84 on page 216 for an example of the output from the command.
Chapter 9. User and Services Management
215
This soft copy for use by IBM employees only.
root@sp21cw0 / > splstdata -e ] pg
List Site Environment Database Information
attribute
value
------------------------------------------------------------------------control_workstation
sp21cw0
cw_ipaddrs
9.12.0.137:9.12.60.98:9.12.60.99:
install_image
bos.obj.ssp.41
remove_image
false
primary_node
1
ntp_config
consensus
ntp_server
″″
ntp_version
3
amd_config
true
print_config
false
print_id
″″
usermgmt_config
true
passwd_file
/etc/passwd
passwd_file_loc
sp21cw0
homedir_server
sp21cw0
homedir_path
/home/sp21cw0
filecoll_config
true
supman_uid
102
supfilesrv_port
8431
spacct_enable
false
spacct_actnode_thresh
80
spacct_excluse_enable
false
acct_master
0
cw_has_usr_clients
false
code_version
PSSP-2.1
layout_dir
/spdata/sys1/syspar_configs/1nsb0isb/config.16/l
authent_server
ssp
backup_cw
″″
ipaddrs_bucw
″″
active_cw
″″
Figure 84. Output from splstdata -e
The locations (server hostname and directory) for user administration files are
also stored in the System Data Repository. These default values may be
changed. However, the /etc/passwd and /etc/security/passwd files are updated
from the Control Workstation. Therefore, if the master copy of these two files is
not located on the Control Workstation, the files must be copied to the Control
Workstation every time they are changed, so that the nodes will be updated with
the correct password information.
9.3.1 Adding an SP User
Before adding an SP user, ensure that the host which is serving user directories
(the Control Workstation in our case) has its /etc/exports file modified to grant
access to all hosts that need to mount the user′s home directory. For example,
add /home/sp21cw0 to /etc/exports on the Control Workstation and then run
exportfs -a. If this is not done, spmkuser will return the following message when
adding a user (harry) on the Control Workstation (sp21cw0).
spmkuser: 0027-122 Warning: User directory, /home/sp21cw0/harry, is in an
unexported filesystem on sp21cw0.
216
SP PD Guide
This soft copy for use by IBM employees only.
If using the SMIT panels to add a user, only the user′s name needs to be
entered. The other fields will default to values contained in the System Data
Repository and in the /usr/lpp/ssp/bin/spmkuser.default file. After the user has
been successfully added, use the Change/Show Characteristics of a User SMIT
panel to check the user′s attributes.
The spmkuser command generates a random password for the user and stores it
in /usr/lpp/ssp/config/admin/newpass.log. The root user has read and write
permission to this file. It is the administrator′s responsibility to communicate
this password to the new user and to delete the contents of this file periodically.
Note: Users can only change their passwords on the Control Workstation.
The administrator must still perform the two following tasks on the Control
Workstation before the new user can successfully login.
1. /etc/amd/refresh_amd
2. dsh -a /var/sysman/supper update user.admin
See the topic 9.5, “Managing Amd” on page 221 for further information on Amd .
See the topic 9.4, “Managing File Collections” on page 218 for further
information on the File Collection . Step 1 will refresh the Amd mount maps. If
this command is not run before the new user attempts to login, the following
error message will be seen at login time:
3004-614 Unable to change directory to ″ / u/xyz″ .
You are in ″ / home/guest″ instead.
Step 2 will make the new user known on all the nodes. This step avoids having
to wait until all the nodes are updated automatically by supper (by default this
happens at 10 past the hour every hour).
9.3.2 Changing User Attributes
When using SP User Management ( usermgmt_config = true), the following base
AIX commands are linked to SP commands on each node:
chfn -> /usr/lpp/ssp/config/sp_chfn
chsh -> /usr/lpp/ssp/config/sp_chsh
passwd -> /usr/lpp/ssp/config/sp_passwd
The original AIX files have been saved in their original location (/bin) with an
extension .aix added. The linked sp_ commands inform users which host to log
in to when changing their password, shell, or gecos information.
user1@sp21n09 / > chsh
Please change your shell info (chsh) at sp21cw0.
After you have done this, it will take up to one hour for the
new shell info to propagate to all nodes.
Figure 85. Example of chsh Command on a Node
Chapter 9. User and Services Management
217
This soft copy for use by IBM employees only.
9.3.3 Login Control
The /usr/lpp/ssp/bin/spacs_cntrl command may be used to control interactive
user access on nodes. The command updates the login and rlogin attributes in
the /etc/security/user file to reflect whether or not a user may login to a node.
For example, dsh -w sp21n09 /usr/lpp/ssp/bin/spacs_cntrl block user1 would
result in the attributes for user1 in /etc/security/user on sp21n09 (node 9) to be
modified as follows:
user1:
login = false
rlogin = false
ttys = ALL,!RSH,!REXEC
Figure 86. Extract from /etc/security/user File
If user1 attempts to login to sp21n09, the following message will appear.
AIX Version 4
(C) Copyrights by IBM and by others 1982, 1994.
login: user1
user1′ s Password:
Remote logins are not allowed for this account.
login:
Figure 87. Example of Login by Blocked User ID
The command, spacs_cntrl unblock user1, can be used to regain login access for
user1 on a node.
For further information on User Access Problems, see Chapters 12 and 27 in the
IBM RISC System/6000 Scalable POWERparallel Systems: Diagnosis and
Messages Guide , GC23-3899.
9.4 Managing File Collections
A file collection is a set of files and directories that are duplicated on multiple
systems in a network and are managed by tools that simplify their control and
maintenance. The /var/sysman/supper command uses the Software Update
Protocol (SUP) to manage RS/6000 SP file collections and transfer them across
the system.
For further information on file collections and the supper command see chapter
14, “Managing File Collections,” in the IBM RISC System/6000 Scalable
POWERparallel Systems: Administration Guide , GC23-3897. RS/6000 SP System
Management: Easy, Lean and Mean , GG24-2563 is also a good source of
information.
218
SP PD Guide
This soft copy for use by IBM employees only.
9.4.1 Using File Collections
If filec = true (use splstdata -e to confirm) then the following sequence will start
the supfilesrv daemon on the Control Workstation.
1. /etc/rc.sp is started from /etc/inittab
2. /usr/lpp/ssp/install/bin/services_config is called from /etc/rc.sp
3. /usr/lpp/ssp/install/bin/file_config is called from services_config
4. Finally, startsrc -s supfilesrv is executed from filec_config
Note: Older versions of filec_config added an entry for supfilesrv to /etc/inittab.
To allow support for multiple Control Workstations, the supfilesrv daemon is now
under System Resource Controller (SRC) control.
root@sp21cw0 / > lssrc -s supfilesrv
Subsystem
Group
PID
supfilesrv
14734
Status
active
Figure 88. Output from lssrc -s supfilesrv Command
9.4.2 supper Hints and Tips
1. If you have problems with the supper command, check the log files in the
/var/adm/SPlogs/filec directory. Alternatively, rerun the command using the
-v option.
2. Error messages similar to those shown in Figure 89 are most likely a result
of mismatched levels of PSSP code on the Control Workstation and the
nodes. Ensure that PSSP components are at the same level on all nodes
and the Control Workstation.
root@sp21cw0 / > supper update user.admin
Updating collection user.admin from server sp21cw0
supper: 0018-258 Update of collection user.admin failed.
supper: 0018-276 Login failed.
Figure 89. supper Error Messages When PSSP Code Is Mismatched
3. Use lssrc -s supfilesrv to check that the supfilesrv daemon is active on the
Control Workstation and on the boot/install servers. This daemon responds
to requests from the nodes to update collections of files.
4. Remember that supper is a pull operation. That is, the command is executed
on the nodes (not on the Control Workstation) and the files are pulled from
the Control Workstation to the nodes.
5. File collections require a unique, unused user ID: supman . If this ID does not
exist, then supper will fail with the same error messages as those shown in
Figure 89. Use the log files in /var/adm/SPlogs/filec on the nodes to obtain
more detailed error messages.
Chapter 9. User and Services Management
219
This soft copy for use by IBM employees only.
SUP 7.24 (4.3 BSD) for file /tmp/.sf10668 at May 13 12:02:12
SUP Upgrade of user.admin at Mon May 13 12:02:12 1996
SUP Fileserver 7.12 (4.3 BSD) 27302 on sp21cw0
SUP Locked collection user.admin for exclusive access
SUP: Reason: Unknown user supman
SUP: Improper login to supman account
SUP: Upgrade of user.admin aborted at Mon May 13 12:02:12 1996
SUP: Aborted
Figure 90. Extract from /var/adm/SPlogs/filec/sup5.13.96.12.02r Log File
6. If a supperupdate <file collection> command seems to execute without any
errors, but the relevant files are not updated on the nodes, check the
following:
•
The supman ID must have read access to all the files in a file collection.
•
Check that the /var/sysman/sup/<file collection>/scan file is correct
and up-to-date. The scan file should contain the same file names as
those in the /var/sysman/sup/<file collection>/list file.
•
Ensure that the date and time on all nodes and the Control Workstation
are correct.
•
Make sure that the files are not listed in the /var/sysman/sup/<file
collection>/refuse file. This file lists all the files which were excluded
during the update process. The /var/sysman/sup/refuse file (if it exists)
contains a list of files to be excluded from all the file collections.
•
Verify the contents of the /etc/ssp/server_name file. This tells supper
from which host it should update files.
7. supper uses the Ethernet network for its communication. Ensure that TCP/IP
is configured correctly.
8. Remember that boot/install servers use supperupdate to request the latest
files from the Control Workstation, and that the nodes use supperupdate to
request the changes from the boot/install servers. Each node executes a
supperupdate every hour (at 10 minutes after the hour) from the root crontab .
This means that a change in a master file on the Control Workstation could
take 2 hours to propagate to every node (assuming that boot/install servers
are being used).
9. Error messages similar to those shown in Figure 91 on page 221 are a result
of a PTF packaging error in PTF 10. There are two missing files in PSSP 2.1
PTF Set 10. They are:
/usr/lpp/ssp/filec/etc/supfilesrv
/usr/lpp/ssp/bin/acctjob
If you are applying PTF Set 10 on a node that has ssp.sysman at level 2.1.0.4
(PTF U441612 ) or earlier, then you must apply PTF Set 8 before installing
PTF Set 10. Installing PTF Set 11, which is a full PTF, will also fix the
problem. If you are applying PTF Set 10 on a node that has ssp.sysman at
level 2.1.0.5 (PTF U441818), then you should not experience any problems.
220
SP PD Guide
This soft copy for use by IBM employees only.
root@ctrws01 / > supper -v update user.admin
Updating collection user.admin from server ctrws01
SUP 7.24 (4.3 BSD) for file /tmp/.sf30822 at MAR 24 13:01:48
SUP Upgrade of user.admin at SUN MAR 24 13:01:48 1996
SUP Locked collection user.admin for exclusive access
SUP: Improper login encryption
supper: 0018-258 Update of collection user.admin failed.
supper: 0018-276 Login failed.
SUP: Improper login to supman account
supper: 0018:258 Update of collection user.admin failed.
supper: 0018:276 Login failed.
SUP: Upgrade of user.admin aborted at SUN Mar24 13:01:48 1996.
SUP: Aborted.
Figure 91. supper Errors When Bypassing PTF Set 8
10. Check and confirm the correctness of the various files and directories as
described in the section Understanding the File Collection Structure in the
IBM RISC System/6000 Scalable POWERparallel Systems: Administration
Guide , GC23-3897.
9.5 Managing Amd
The Berkley automounter, Amd , can be used to manage NFS mounting of home
directories and other directories. When configured, Amd mounts filesystems on
demand when they are first referenced and also unmounts them after a period of
inactivity.
For further information on the use of Amd tool, see Chapter 15, “Managing
Amd,” in the IBM RS/6000 Scalable POWERparallel Systems: Administration
Guide , GC23-3897. RS/6000 SP System Management: Easy, Lean and Mean ,
GG24-2563 is also a good source of information.
9.5.1
Using Amd
To make use of Amd, set amd_config = true using the spsitenv command (use
splstdata -e to check the value, if necessary). If amd_config = true, then the
following sequence will start the Amd daemon at boot time.
1. /etc/rc.sp is started from /etc/inittab
2. /usr/lpp/ssp/install/bin/services_config is called from /etc/rc.sp
3. /usr/lpp/ssp/install/bin/amd_config is called from services_config
4. Finally, /etc/amd/amd_start is called from services_config
5. amd_start starts the A m d daemon with the parameters as shown in
Figure 92.
/etc/amd/amd -t 16.120 -x all /var/adm/SPlogs/amd/amd.log -p /u /etc/amd/maps/amd.u
Figure 92. Default Options Starting the A m d Daemon
Chapter 9. User and Services Management
221
This soft copy for use by IBM employees only.
For further information on Amd options, refer to the man pages in
/usr/lpp/ssp/public/amd920824upl75.tar.Z. The man pages can be extracted with
the commands:
zcat amd920824upl75.tar.Z |
zcat amd920824upl75.tar.Z |
mv amd920824upl75/amd/amd.8
mv amd920824upl75/amq/amq.8
tar -xvf - amd920824upl75/amd/amd.8
tar -xvf - amd920824upl75/amq/amq.8
/usr/man/man8
/usr/man/man8
9.5.2 Amd Hints and Tips
1. Do not use kill -9 <pid> to stop the A m d daemon. Use kill -15 <pid>
instead. Using kill -9 can cause the Amd daemon to hang. Rebooting the
affected node is the only way to recover from the hang.
2. Before running /etc/amd/amd_start -f, unmount all filesystems which have
been mounted by Amd. This will ensure that the same filesystems are not
mounted multiple times, which could potentially cause problems.
root@sp21n09 / > df
Filesystem
512-blocks
/dev/hd4
16384
/dev/hd2
589824
/dev/hd9var
8192
/dev/hd3
24576
/dev/hd1
8192
sp21cw0:/tony
40960
sp21cw0:/tony
40960
sp21n09:(pid3472)
sp21n09:(pid3472)
sp21cw0:/tony
40960
Free %Used
Iused %Iused Mounted on
6960
58%
1050
26% /
11936
98%
11188
16% /usr
5440
34%
334
33% /var
23320
6%
40
1% /tmp
7840
5%
18
2% /home
39312
5%
- /a/sp21cw0/tony
39312
5%
- /a/sp21cw0/tony
0
0
-1%
- /u
0
0
-1%
- /auto
39312
5%
- /a/sp21cw0/tony
Figure 93. Example of Output from df Command Showing Multiple Mounts
If multiple mounts of the same filesystem have occurred (as in Figure 93),
then try to unmount all the Amd-mounted filesystems. The command umount
/a/sp21cw0/tony will need to be run three times in the example. Then run
/etc/amd/amd_start -f. This will clear up any problems (in most cases).
3. If filesystems which should be automounted are not, check whether the A m d
daemon is running. Also make sure that the map files in
/etc/amd/amd-maps are correctly configured. See Figure 93 as an example
of a map file. Ensure that the map files are the same on all the nodes (use
supper to update them, if necessary). If everything looks correct, restart the
daemon (on the Control Workstation and each node) by using the amd_start
-f command.
222
SP PD Guide
This soft copy for use by IBM employees only.
# This file contains the definition of the amd maps for /auto.
# /etc/amd/amd-maps/amd.auto
/defaults
type:=nfs;opts:=rw,soft;sublink:=${key}
one
host==sp21cw0;type:=link;fs:=/tony \
host!=sp21cw0;type:=nfs;rhost:=sp21cw0;rfs:=/tony
two
host==sp21cw0;type:=link;fs:=/tony \
host!=sp21cw0;type:=nfs;rhost:=sp21cw0;rfs:=/tony
three
host==sp21cw0;type:=link;fs:=/tony \
host!=sp21cw0;type:=nfs;rhost:=sp21cw0;rfs:=/tony
four
host==sp21cw0;type:=link;fs:=/tony \
host!=sp21cw0;type:=nfs;rhost:=sp21cw0;rfs:=/tony
Figure 94. Sample A m d Map File
The example in Figure 94 will mount the directory /tony (and its
subdirectories) on the Control Workstation and on the nodes as /auto. On
the Control Workstation, the original directory (/tony) will be linked to /auto.
4. After creating a new A m d map file, use dsh to copy the file to each node.
Then run /etc/amd/amd_start -f to restart Amd. This makes it unnecessary
to reboot all the nodes that have the new map.
5. If one of the following error messages shown in Figure 95 is returned when
trying to access a filesystem mounted by Amd, ensure that the filesystem
has been exported on the server.
root@sp21n09 / > cd /auto/one
ksh[2]: /auto/one: permission denied
root@sp21n09 / > cd /auto
root@sp21n09 /auto > cd one
ksh[2]: one: not found
Figure 95. Error Messages When the Filesystem Is Not Exported
To correct this problem, add the filesystem to /etc/exports and run exportfs
-a on the server.
root@sp21n09
root@sp21n09
total 0
-rwxrwxrwx
-rwxrwxrwx
-rwxrwxrwx
/ > cd auto/one
/auto/one > ls -l
1 root
1 root
1 root
system
system
system
0 May
0 May
0 May
9 10:04 a.1
9 10:04 b.1
9 10:04 c.1
Figure 96. Output after Exporting /tony on the Control Workstation
Chapter 9. User and Services Management
223
This soft copy for use by IBM employees only.
6. Sometimes problems with A m d may be caused by the Network File System
(NFS) subsystem. Use the command lssrc -g nfs to check the status of the
NFS subsystem, as shown in Figure 97 on page 224.
root@sp21n09 / > lssrc -g nfs
Subsystem
Group
biod
nfs
nfsd
nfs
rpc.mountd
nfs
rpc.statd
nfs
rpc.lockd
nfs
PID
5836
7146
8968
9496
9768
Status
active
active
active
active
active
Figure 97. Example of Output from lssrc -g nfs Command
7. Use the /var/adm/SPlogs/amd/amd.log file to get further information on A m d
problems. Figure 98 shows the log entries when amd_start -f is run
successfully.
May 10 13:31:06 sp21n09 amd[13924]/info:
May 10 13:31:06 sp21n09 amd[10598]/info:
May 10 13:31:06 sp21n09 amd[10598]/map:
on /u fstype toplvl
May 10 13:31:06 sp21n09 amd[10598]/map:
on /auto fstype toplvl
/etc/amd/amd_start: kill -TERM 11324 ..
My ip addr is 0x90c3c09
file server localhost type locals starts up
Trying mount of /etc/amd/amd-maps/amd.u
Trying mount of /etc/amd/amd-maps/amd.auto
/etc/amd/amd_start: Starting Amd on Fri May 10 13:31:04 CDT 1996
/etc/amd/amd_start: Started Amd on Fri May 10 13:31:04 CDT 1996
May 10 13:31:06 sp21n09 amd[10598]/warn: NIS domain name is not set. NIS ignored.
May 10 13:31:06 sp21n09 amd[10598]/info: /etc/amd/amd-maps/amd.u mounted fstype toplvl
on /u
May 10 13:31:06 sp21n09 amd[10598]/info: /etc/amd/amd-maps/amd.auto mounted fstype
toplvl on /auto
/etc/amd/amd_start: kill -TERM 11324 ..
Figure 98. Extract from amd.log File after amd_start -f Command
Figure 99 shows the log entries when trying to change directory (cd) to an
automounted directory which has not been exported on the server.
May 10 13:43:57 sp21n09
not match sp21cw0
May 10 13:43:57 sp21n09
for /auto/one failed to
May 10 13:43:57 sp21n09
fstype nfs
May 10 13:43:57 sp21n09
amd[10598]/map: key one: map selector host (=sp21n09) did
amd[10598]/map: Map entry host==sp21cw0;type:=link;fs:=/tony
match
amd[10598]/map: Trying mount of sp21cw0:/tony on /auto/one
amd[10598]/info: Filehandle denied for ″sp21cw0:/tony″
Figure 99. Extract from amd.log When Filesystem Is Not Exported
224
SP PD Guide
This soft copy for use by IBM employees only.
9.6 Managing Print Services
Print management tools are supplied with PSSP 2.1 to shift printing functions
from the nodes to a print server, eliminating the need to maintain and support
print queues on a large number of nodes. An RS/6000 SP node is designed to
use a unique remote host, PRINT_HOST, as a print server.
For further information on the use of the SP Print Management System see
Chapter 16 “Managing Print Service” in the IBM RISC System/6000 Scalable
POWERparallel Systems: Administration Guide , GC23-3897.
9.6.1 Using Print Services
The SP Print Management System can run in either Open , or Secure Mode.
For Secure Mode set print_config = secure and print_id = prtid . For Open
Mode, set print_config = open . Use either smitty site_env_dialog or spsitenv
to set these values.
Secure Mode requires only one user ( prtid ) to have rsh privileges on the print
server. This user account is responsible for transferring all print jobs to the print
server.
Open Mode requires all users who need access to a printer to have rsh
privileges on the print server. Therefore, these users can execute other
commands on the print server through rsh as well, which could pose a security
exposure.
If print_config = secure or open , then the following sequence will configure Print
Services:
1. /etc/rc.sp is started from /etc/inittab
2. /usr/lpp/ssp/install/bin/services_config is called from /etc/rc.sp
3. /usr/lpp/ssp/install/bin/print_config is called from services_config
The print_config script copies all the print commands in /usr/bin to cmd.AIX .
The base AIX print commands are then linked to /usr/lpp/ssp/bin/pmswitch. If
Secure Mode is used, then /usr/lpp/ssp/bin/pmbec has setuid permission added.
9.7 Managing NTP
A mechanism to synchronize clocks is needed because the RS/6000 SP nodes do
not have system batteries. Network Time Protocol (NTP) is used as the default
mechanism, on the RS/6000 SP system, to achieve this. The RS/6000 SP uses
NTP to set the time at system initialization and to synchronize time-of-day clocks
on the Control Workstation and nodes. Other time-service protocols (timed or
Digital Time Service) may be used instead of NTP.
For further information on NTP, see chapter 13 “Managing NTP” in the IBM RISC
System/6000 Scalable POWERparallel Systems: Administration Guide , GC23-3897.
Chapter 5 “The Network Time Protocol” in RS/6000 SP System Management:
Easy, Lean and Mean , GG24-2563 is also a good source of information.
Chapter 9. User and Services Management
225
This soft copy for use by IBM employees only.
9.7.1 Using NTP
If ntp_config = [consensus/timemaster/internet] (use splstdata -e to confirm),
then the following sequence will start the xntp daemon on the Control
Workstation and the nodes:
1. /etc/rc.sp is started from /etc/inittab
2. /usr/lpp/ssp/install/bin/services_config is called from /etc/rc.sp
3. /usr/lpp/ssp/install/bin/ntp_config is called from services_config
4. /etc/rc.ntp is called from ntp_config
5. /usr/lpp/ssp/bin/xntp is started from rc.ntp
The ntp_config script creates the /etc/ntp.conf and /etc/rc.ntp files. The ntp.conf
file indicates which hosts can provide time service to which other hosts.
For further information on NTP, refer to the man pages in
/usr/lpp/ssp/public/ntp.tar.Z. The man pages can be extracted with the
commands:
zcat ntp.tar.Z | tar -xvf - ntp/doc/xntpd.8
zcat ntp.tar.Z | tar -xvf - ntp/doc/xntpdc.8
zcat ntp.tar.Z | tar -xvf - ntp/doc/ntpq.8
zcat ntp.tar.Z | tar -xvf - ntp/doc/ntpdate.8
zcat ntp.tar.Z | tar -xvf - ntp/doc/ntptrace.8
mv ntp/doc/xntp*.8 /usr/man/man8
mv ntp/doc/ntp*.8 /usr/man/man8
9.7.2 NTP Hints and Tips
1. If the time difference between the Kerberos authentication server and the
nodes is not greater than 5 minutes, then the Kerberos-authenticated
commands will continue to execute.
2. Use kill -15 <NTP pid> to kill the NTP daemon before restarting it.
3. Use /etc/rc.ntp to start the NTP daemon, if necessary.
4. How to change the system time.
•
Create a .rhost file. This will be needed to execute rsh commands after
the Control Workstation time has been changed (as Kerberos commands
will no longer work).
root@sp21cw0 / > cat /.rhosts
sp21cw0 root
root@sp21cw0 / >
Figure 100. Example of /.rhosts File
226
SP PD Guide
•
Use pcp -a /.rhost / to copy the .rhost file to all the nodes.
•
Use smitty date to change the system date on the Control Workstation.
•
Execute the following script on the Control Workstation:
This soft copy for use by IBM employees only.
for i in hostlist -av
do
/usr/bin/rsh $i ′ kill -15 ps -e | grep xntp | grep -v grep |
cut -c1-6′
/usr/bin/rsh $i /etc/rc.ntp
done
This script will stop the NTP daemon on each node and then restart it.
This will synchronize the time on the nodes with the Control Workstation.
•
Use dsh -a rm /.rhost to delete the .rhost file on all the nodes. Notice
that because the time is synchronized, Kerberos commands work again.
Chapter 9. User and Services Management
227
This soft copy for use by IBM employees only.
228
SP PD Guide
This soft copy for use by IBM employees only.
Appendix A. RS/6000 SP Script Files
Many of the SP tasks are carried out by script files. This appendix provides flow
charts for the main PSSP scripts, which can be used as a reference for problem
determination.
A.1 The setup_authent Script
The setup_authent script provides the initial setup for the Kerberos
authentication services. This script has several built-in functions which are
included in separate flow charts to keep the descriptions clear.
Figure 101. setup_authent Script Flow Chart (1/7)
 Copyright IBM Corp. 1996
229
This soft copy for use by IBM employees only.
Figure 102. setup_authent Script Flow Chart (2/7)
230
SP PD Guide
This soft copy for use by IBM employees only.
Figure 103. setup_authent Script Flow Chart (3/7)
Appendix A. RS/6000 SP Script Files
231
This soft copy for use by IBM employees only.
Figure 104. setup_authent Script Flow Chart (4/7)
232
SP PD Guide
This soft copy for use by IBM employees only.
Figure 105. setup_authent Script Flow Chart (5/7)
Appendix A. RS/6000 SP Script Files
233
This soft copy for use by IBM employees only.
Figure 106. setup_authent Script Flow Chart (6/7)
234
SP PD Guide
This soft copy for use by IBM employees only.
Figure 107. setup_authent Script Flow Chart (7/7)
Appendix A. RS/6000 SP Script Files
235
This soft copy for use by IBM employees only.
A.2 The install_cw Script
This script is invoked during the installation procedure. The CW is installed
here, creating the directory structure and setting up the process and subsystems
infrastructure that will manage the RS/6000 SP.
Figure 108. install_cw Script Flow Chart (1/3)
236
SP PD Guide
This soft copy for use by IBM employees only.
Figure 109. install_cw Script Flow Chart (2/3)
Appendix A. RS/6000 SP Script Files
237
This soft copy for use by IBM employees only.
Figure 110. install_cw Script Flow Chart (3/3)
238
SP PD Guide
This soft copy for use by IBM employees only.
A.3 The setup_server Script
This script is run to check and configure boot/install servers. It can be run from
the Control Workstation or from the nodes which will be used as boot/install
servers.
Figure 111. setup_server Script Flow Chart (1/23)
Appendix A. RS/6000 SP Script Files
239
This soft copy for use by IBM employees only.
Figure 112. setup_server Script Flow Chart (2/23)
240
SP PD Guide
This soft copy for use by IBM employees only.
Figure 113. setup_server Script Flow Chart (3/23)
Appendix A. RS/6000 SP Script Files
241
This soft copy for use by IBM employees only.
Figure 114. setup_server Script Flow Chart (4/23)
242
SP PD Guide
This soft copy for use by IBM employees only.
Figure 115. setup_server Script Flow Chart (5/23)
Appendix A. RS/6000 SP Script Files
243
This soft copy for use by IBM employees only.
Figure 116. setup_server Script Flow Chart (6/23)
244
SP PD Guide
This soft copy for use by IBM employees only.
Figure 117. setup_server Script Flow Chart (7/23)
Appendix A. RS/6000 SP Script Files
245
This soft copy for use by IBM employees only.
Figure 118. setup_server Script Flow Chart (8/23)
246
SP PD Guide
This soft copy for use by IBM employees only.
Figure 119. setup_server Script Flow Chart (9/23)
Appendix A. RS/6000 SP Script Files
247
This soft copy for use by IBM employees only.
Figure 120. setup_server Script Flow Chart (10/23)
248
SP PD Guide
This soft copy for use by IBM employees only.
Figure 121. setup_server Script Flow Chart (11/23)
Appendix A. RS/6000 SP Script Files
249
This soft copy for use by IBM employees only.
Figure 122. setup_server Script Flow Chart (12/23)
250
SP PD Guide
This soft copy for use by IBM employees only.
Figure 123. setup_server Script Flow Chart (13/23)
Appendix A. RS/6000 SP Script Files
251
This soft copy for use by IBM employees only.
Figure 124. setup_server Script Flow Chart (14/23)
252
SP PD Guide
This soft copy for use by IBM employees only.
Figure 125. setup_server Script Flow Chart (15/23)
Appendix A. RS/6000 SP Script Files
253
This soft copy for use by IBM employees only.
Figure 126. setup_server Script Flow Chart (16/23)
254
SP PD Guide
This soft copy for use by IBM employees only.
Figure 127. setup_server Script Flow Chart (17/23)
Appendix A. RS/6000 SP Script Files
255
This soft copy for use by IBM employees only.
Figure 128. setup_server Script Flow Chart (18/23)
256
SP PD Guide
This soft copy for use by IBM employees only.
Figure 129. setup_server Script Flow Chart (19/23)
Appendix A. RS/6000 SP Script Files
257
This soft copy for use by IBM employees only.
Figure 130. setup_server Script Flow Chart (20/23)
258
SP PD Guide
This soft copy for use by IBM employees only.
Figure 131. setup_server Script Flow Chart (21/23)
Appendix A. RS/6000 SP Script Files
259
This soft copy for use by IBM employees only.
Figure 132. setup_server Script Flow Chart (22/23)
260
SP PD Guide
This soft copy for use by IBM employees only.
Figure 133. setup_server Script Flow Chart (23/23)
Appendix A. RS/6000 SP Script Files
261
This soft copy for use by IBM employees only.
A.4 The rc.switch Script
Figure 134. rc.switch Script Flow Chart (1/8)
262
SP PD Guide
This soft copy for use by IBM employees only.
Figure 135. rc.switch Script Flow Chart (2/8)
Appendix A. RS/6000 SP Script Files
263
This soft copy for use by IBM employees only.
Figure 136. rc.switch Script Flow Chart (3/8)
264
SP PD Guide
This soft copy for use by IBM employees only.
Figure 137. rc.switch Script Flow Chart (4/8)
Appendix A. RS/6000 SP Script Files
265
This soft copy for use by IBM employees only.
Figure 138. rc.switch Script Flow Chart (5/8)
266
SP PD Guide
This soft copy for use by IBM employees only.
Figure 139. rc.switch Script Flow Chart (6/8)
Appendix A. RS/6000 SP Script Files
267
This soft copy for use by IBM employees only.
Figure 140. rc.switch Script Flow Chart (7/8)
268
SP PD Guide
This soft copy for use by IBM employees only.
Figure 141. rc.switch Script Flow Chart (8/8)
Appendix A. RS/6000 SP Script Files
269
This soft copy for use by IBM employees only.
270
SP PD Guide
This soft copy for use by IBM employees only.
Appendix B. The SDR Structure
The SDR is the central data repository for the RS/6000 SP. The communication
with the SDR is through a client/server relationship. The server is represented
by a process (daemon) running on the Control Workstation, the client portion is
represented by different SP commands, and it is also represented by SP
subsystems that query the SDR to retrieve information about the SP
configuration or values for state variables.
The organization of the SDR database is based on object classes. Each object
class contains different attributes, and there can be many instances of a
particular object class.
When the SP is partitioned, some of the SDR classes are also partitioned. Each
partition will have a different SDR process (daemon) who will manage the SDR
database portion that has been partitioned.
Figure 142. The SDR Structure
 Copyright IBM Corp. 1996
271
This soft copy for use by IBM employees only.
272
SP PD Guide
This soft copy for use by IBM employees only.
Appendix C. IP Address and Hostname Changes for the SP
This information describes the activities that the admin user needs to execute
when changing the IP address or hostname for the RS/6000 SP nodes and
Control Workstation (CW). It is highly recommended to avoid making any IP
address or hostname changes if possible. The tasks are strenuous and in some
cases require re-execution of the installation steps.
The changing of the IP addresses/hostnames of RS/6000 SP nodes affect the
whole RS/6000 SP system. IP addresses/hostnames are located in the System
Data Repository (SDR) working with objects and attributes.
IP addresses/hostnames are also kept in various files that are located on the
RS/6000 SP nodes and the CW. These changes will also cause problems with
Network Installation Manager (NIM) and System Partition objects and
configuration files on your RS/6000 SP system.
C.1 SDR Objects
The SDR objects that reference the hostname and IP address changes are :
Adapters
Deals with ent, css0, tr0, fi0 IP addresses and
adapters.
Frame
Deals with the MACN CWS attribute and works with
hostnames.
Node
Works with initial/reliable hostnames and uses the
IP address for boot servers. Node objects are
organized in system partitions.
SP
Deals mostly with CW attributes, but uses hostname
when working with ntp, printing, user management,
and accounting.
SP_ports
Deals with hostname used with hardmon and CW.
Switch_partition
Works with hostname of primary node used with
switch.
JM_domain,Pool
Works with Resource Manager and references
hostnames.
Syspar
Deals with IP address and SP_NAME used with
system partitions.
C.2 RS/6000 SP System Files
The following are files that contain IP addresses, or hostnames that exist on
RS/6000 SP nodes and the CW. It is best to look through these files when
completing the procedures for changing hostnames and IP addresses for your
RS/6000 SP system.
/.rhosts
Contains hostnames used exclusively with rcmd
services
/.klogin
Contains hostnames used with authentication
rcmd services
 Copyright IBM Corp. 1996
273
This soft copy for use by IBM employees only.
274
SP PD Guide
/etc/hosts
Contains IP addresses and hostnames used
with RS/6000 SP system
/etc/resolv.conf
Contains IP address for domain name service
(Optional)
/etc/rc.net
Contains alias IP addresses used with system
partitions
/var/yp/<nis>
Network Information Service references IP
address/hostname
/etc/niminfo
Works with the NIM configuration for NIM
master information
/etc/krb.conf
Works with hostname for authentication server
/etc/krb.realms
Works with hostname of RS/6000 SP nodes and
authentication server
/etc/krb-srvtab
Provides authentication service key using
hostname
/etc/SDR_dest_info
Specifies hostname and IP address of the CW
and SDR
/etc/ssp/cw_name
Specifies the IP address of the CW hostname
(RS/6000 SP nodes)
/etc/ssp/server_name
Specifies IP address and hostname of RS/6000
SP server of the boot/install adapter servers
(RS/6000 SP nodes)
/etc/ssp/server_hostname
Specifies IP address and hostname of RS/6000
SP server
/etc/ssp/reliable_hostname
Specifies IP address and hostname of RS/6000
SP node
/etc/ntp.conf
Works with IP address of the ntp server
(Optional)
/etc/filesystems
May contain IP address or hostname of nfs
systems mainly used on /usr client systems
/etc/jmd_config
Works with hostnames for Resource
Management pools (CW)
/tftpboot/<host>.config_info
Contains IP address and hostname for each
RS/6000 SP node, and is found on CW and boot
servers
/tftpboot/<host>.intstall_info
Contains IP address and hostname for each
RS/6000 SP node, and is found on CW and boot
servers
/tftpboot/<host>-new-srvtab
Provides authentication service keys using
hostname, and is found on CW and boot servers
This soft copy for use by IBM employees only.
C.3 Procedures Used When Changing IP Addresses/Hostnames
The changing of an IP address or hostname for a RS/6000 SP node and CW will
follow the same procedures, except that the Control Workstation will include
additional network and RS/6000 SP configuration steps.
You will need to update PSSP files and interfaces on the RS/6000 SP nodes. You
will need to update the “en0” network interface on each RS/6000 SP node that
has IP address, domain, or hostname changes. You will need to know the new
selected IP addresses and hostnames being used by the RS/6000 SP nodes,
Control Workstation, and gateway servers. This is required so that the RS/6000
SP node will properly communicate to the Control Workstation during the reboot
activity. It will be necessary to do this activity manually for each RS/6000 SP
node.
You will need to work on the Control Workstation and make the necessary
changes to the System Data Repository (SDR). This includes updates to reset
PSSP daemons, and system partitions (syspar) files. You need to update files on
the Control Workstation to reflect the new hostnames and IP addresses. During
this activity, the RS/6000 SP system should not be available to users. The
RS/6000 SP system is not ready until the RS/6000 SP nodes reference the new IP
address/hostname changes.
You will need to set the boot response to customize and then execute a reboot for
the RS/6000 SP nodes. After the RS/6000 SP nodes have completed the reboot
and customized, you should verify that the files on RS/6000 SP nodes reflect the
new IP address/hostname changes.
The added Install support in AIX 4.1 for NIM requires the admin user to replace
the NIM master objects. It may be necessary to update the NIM network and
machine resources to match the new IP address or hostname. The NIM updates
will be needed for the CWS and bootserver nodes.
If you had previously used System Partitioning on your RS/6000 SP system, it will
be necessary to re-execute the system partition steps on your system. This will
allow the necessary syspar config files to reflect any changes.
C.4 Updating the RS/6000 SP Node Interfaces
The following RS/6000 SP node updates need to be made on every RS/6000 SP
node prior to updates made to the Control Workstation (CW).
1. Updating the RS/6000 SP node “ e n 0 ” Interface
You now need to update the “en0” interface on each RS/6000 SP node to
allow the proper communication paths between the RS/6000 SP node and the
Control Workstation. You need to change the en0 interface to the new IP
address/hostname. You will also supply the proper gateway and route
information for the en0 adapter. You do not need to modify any other
adapter interfaces on the RS/6000 SP node. To accomplish this task you
should use the mktcpip command. This can be executed through smit
mktcpip or the mktcpip command on each RS/6000 SP node.
The following are examples of using the mktcpip command.
mktcpip -h <new node hostname> -a <new node IP addr> -m <subnet mask> \
-i en0 -n <name server> -d <domain> -g <gateway IP addr> -t N/A
Appendix C. IP Address and Hostname Changes for the SP
275
This soft copy for use by IBM employees only.
The following will change the hostname of node “k22n06” to be referenced
as new node hostname “k88n06” in domain “ppd.pok.ibm.com.”
/usr/sbin/mktcpip -h′ k88n06.ppd.pok.ibm.com′ -a′129.40.88.70′
-m′255.255.255.192′ -i′ en0′ -n′129.40.70.1′ -d′ ppd.pok.ibm.com′
-g′129.40.88.126′ -t′ N/A′
\
\
2. Update the NIM files and configuration
a. You will need to update the /etc/niminfo file to provide the new and IP
address and hostname changes for the nim client, master, and file
references.
b. If the node is a NIM master or a bootserver, you should remove all NIM
objects from the node. This is accomplished by executing the following.
/usr/sbin/nim -o unconfig master
/usr/sbin/installp -u bos.sysmgt.nim.master
3. Update PSSP files for updates
You will need to update the following files to place the new IP address and
hostname information for node and server information.
a. Update the /etc/SDR_dest_info file using new CW and SDR IP addresses
b. Update the /etc/ssp/ files cw_name server_hostname, server_name to
reference the new boot server hostname and IP address.
c. Update the /etc/ssp/reliable_hostname file to reference the new node
client hostname and IP address.
d. Make sure that SP_NAME environment variable is updated or blank.
e. Execute a /usr/lpp/ssp/kerberos/bin/kdestroy to remove any active
kerberos ticket-granting-tickets. You may need to update the
/etc/krb.conf file to point to the correct kerberos server.
Your update should now be completed at the RS/6000 SP node. You need to
make the changes at the Control Workstation and then reboot the RS/6000 SP
nodes.
C.5 Control Workstation IP Address/Hostname Changes
The following tasks need to be executed by the admin (root) user on the Control
Workstation when changing the Ethernet IP addresses or hostname.
1. In a System Partition configuration, save the current SDR attributes by
executing an archive /usr/lpp/ssp/bin/SDRArchive.
You may want to backup the current /spdata filesystem in case there are
problems doing the IP Address/hostname changes.
You will need to reference the current and the new IP addresses/hostnames
along with possible changes regarding system partition names (SP_NAME).
You may want to reset the SP system back into one default system partition
prior to changing the IP address hostname in the SDR.
2. Stop all the PSSP daemons sdr, hb, hr, hardmon on the CW.
/bin/stopsrc
/bin/stopsrc
/bin/stopsrc
/bin/stopsrc
276
SP PD Guide
-g
-g
-g
-s
sdr
hb
hr
hardmon
This soft copy for use by IBM employees only.
3. Remove the current source master objects for sdr, hb and hr for each
system partition (SP_NAME) reference.
/usr/lpp/ssp/bin/sdr -spname <SP_NAME> rmsrc
/usr/lpp/ssp/bin/hb -spname <SP_NAME> rmsrc
/usr/lpp/ssp/bin/hr -spname <SP_NAME> rmsrc
4. Using mktcpip or the chdev command, specify the new IP address or
hostname changes required for the Control Workstation.
If multiple system partitions exist, update the “/etc/rc.net” file to reference
the new alias addresses used for system partitions. Execute the
“/etc/rc.net” to configure the new alias addresses.
5. Manually update /etc/SDR_dest_info and /spdata/sys1/spmon/hmacls files to
the new IP address and hostname used with hardmon and SDR.
Move the system partition directories found at location
/spdata/sys1/sdr/partitions from old IP addresses to the new IP addresses
for each system partition reference.
/bin/mv
<OLD IP_ADDR>
<New IP_ADDR>
6. Execute the setup_authent script to create authentication services for the
new hostname being used. This step should only be executed for hostname
changes for the CW. It is not required for changes made to IP addresses, or
with RS/6000 SP node updates. Reference Step 12 in the RS/6000 SP
Installation Guide. Manually check that the authentication files /etc/krb.conf,
/etc/krb.realms, and /etc/krb-srvtab reference the new hostname.
7. You need to now create the new source master resources for the sdr, hb and
hr daemons. This may be possible by executing the
/usr/lpp/ssp/inst_root/ssp.basic.post_i script to recreate the daemons, and
then start the daemons.
8. After the sdr daemon has been properly activated on the SP system,
manually execute “SDRChangeAttrValues” for the Control Workstation.
a. Change “hostname” attribute using new hostname for “SP_ports” object.
b. Change “MACN” attribute using new hostname for “Frame” object.
c. Change “control_workstation” attribute using short hostname for “ S P ”
object.
9. You will want to remove the current Network Installation Manager (NIM)
database and configuration files on the CW. You need to execute:
/usr/sbin/nim -o unconfig master
/usr/sbin/installp -u bos.sysmgt.nim.master
10. You may want to “reboot” the control workstation now. This will establish a
clean system to reflect the IP address/hostname changes. You want to verify
that all PSSP daemons are getting activated from the “/etc/inittab.”
11. Using CMI or the spsitenv command, specify any hostname changes that
may be referenced for ntp, printing, and user management. Reference Step
15 in the RS/6000 SP Installation Guide. (This is optional.)
12. Update the SDR objects using commands, or by using the SMIT-based 9076
SP Configuration Management Interface (CMI). You may need to execute the
following activities from each system partition.
Appendix C. IP Address and Hostname Changes for the SP
277
This soft copy for use by IBM employees only.
a. Using CMI or the spethernt command, specify the new Ethernet IP
address or hostname change required for the RS/6000 SP nodes.
Reference Step 18 in the RS/6000 SP Installation Guide.
b. Using CMI or the spadaptrs command, reset the “css0” and other
adapters that need to reference the new Ethernet IP address/hostname
that was changed. Reference step 22 in the RS/6000 SP Installation
Guide.
c. Using CMI or the sphostnam command, reset the initial hostname that you
want to use in your system. Reference Step 23 in the RS/6000 SP
Installation Guide. (This is optional.)
d. Using CMI or the spbootins command, reset the boot install server to
reference the new Ethernet IP address/hostname that was changed. You
will need to set bootp response to “customize” for the RS/6000 SP
nodes.
The spbootins will execute the setup_server command, which will create all
the NIM-based files and resources required for installation. It will also
create the authentication principals for the new RS/6000 SP nodes.
You may want to manually verify that the following files have been
successfully updated after running the previously CMI steps:
/etc/ntp.conf
/tftpboot/<host>.config_info
/tftpboot/<host>.install_info
/tftpboot/<host>-new-srvtab
13. You may want to re-execute the system partitioning steps that are specified
in Chapter 5 of the System Administrators Guide. Update other files on the
CW that may reflect IP address or hostname changes.
a. Update any files that are involved with hostname resolution. The files
are /etc/hosts, /etc/resolv.conf (dns), and /var/yp/* (nis).
b. Update the .rhosts or .klogin files that may exist.
c. Update the /etc/filesystems and / e t c / j m d _ c o n f i g . < S P _ N A M E > files for
your RS/6000 SP configuration.
d. You should also check to make sure your /tftpboot/script.cust file is
updated to reflect IP address/hostname changes. Instead of hardcoding
hostnames, you may reference the $SERVER and $CW variables.
14. You can now execute a “reboot” on each of the RS/6000 SP nodes. This can
be accomplished using the System Monitor GUI. Follow the same install
sequence as during installation: customize the boot servers first, and then
customize the remaining RS/6000 SP nodes. For each bootserver node you
will need to unconfigure NIM and re-execute setup_server to create the
Installation files. Since the RS/6000 SP nodes are in customize mode, most
configuration files will be updated to reflect the IP address/hostname
changes.
Some files will not be updated on the nodes during the customization. You may
want to “rcp” these files from the CW to the RS/6000 SP nodes by including them
in the /tftpboot/script.cust file. These may include the /etc/resolv.conf, /.rhosts,
and other RS/6000 SP customer-owned files.
278
SP PD Guide
This soft copy for use by IBM employees only.
C.6 Execution on RS/6000 SP Nodes
The following steps will need to be executed for IP address and hostname
changes for both the Control Workstation and the RS/6000 SP nodes. These
steps will be executed on each of the RS/6000 SP nodes.
1. After the reboot has completed, and your RS/6000 SP nodes have initialized,
verify that the following have the correct IP address and hostname.
•
Updated SP Ethernet address specified for the RS/6000 SP node.
•
Updated default route is correct.
•
Hostname resolution files were updated correctly (/etc/hosts).
•
The /etc/SDR_dest_info file points to the CW and SDR addresses.
•
The acct_master hostname is updated for NFS export list directory
/var/adm/acct (RS/6000 SP Accounting).
•
Files in directory /etc/ssp cw_name, server_hostname, server_name, and
reliable_hostname point to the correct IP address/hostnames.
•
The files /etc/krb.conf, /etc/krb.realms, and /etc/krb-srvtab have the
correct hostnames defined.
2. You may have to modify the following files on the RS/6000 SP nodes to
reflect the updated IP addresses and hostname definitions.
/etc/filesystems
/etc/ntp.conf
/etc/resolv.conf
/.rhosts
/.klogin
If any of the files are not correct, make the proper updates for the correct IP
address or hostname yourself.
3. You will want to remove the current Network Installation Manager (NIM)
database and configuration files on any PSSP 2.1 bootserver node.
/usr/sbin/nim -o unconfig master
/usr/sbin/installp -u bos.sysmgt.nim.master
You should then execute setup_server on the bootserver node.
4. It is best to reboot all of the RS/6000 SP nodes to reflect the IP address and
hostname changes. When the RS/6000 SP nodes initialize, your RS/6000 SP
system should be activated using the new IP addresses and hostnames.
Appendix C. IP Address and Hostname Changes for the SP
279
This soft copy for use by IBM employees only.
280
SP PD Guide
This soft copy for use by IBM employees only.
Appendix D. Special Notices
This publication is intended to help technical professionals to better understand
and be able to handle RS/6000 SP-related problems. The information in this
publication is not intended as the specification of any programming interfaces
that are provided by RS/6000 SP or POWERparallel System Support Programs.
See the PUBLICATIONS section of the IBM Programming Announcement for
RS/6000 SP and POWERparallel System Support Programs for more information
about what publications are considered to be product documentation.
References in this publication to IBM products, programs or services do not
imply that IBM intends to make these available in all countries in which IBM
operates. Any reference to an IBM product, program, or service is not intended
to state or imply that only IBM′s product, program, or service may be used. Any
functionally equivalent program that does not infringe any of IBM′s intellectual
property rights may be used instead of the IBM product, program or service.
Information in this book was developed in conjunction with use of the equipment
specified, and is limited in application to those specific hardware and software
products and levels.
IBM may have
this document.
these patents.
Licensing, IBM
patents or pending patent applications covering subject matter in
The furnishing of this document does not give you any license to
You can send license inquiries, in writing, to the IBM Director of
Corporation, 500 Columbus Avenue, Thornwood, NY 10594 USA.
Licensees of this program who wish to have information about it for the purpose
of enabling: (i) the exchange of information between independently created
programs and other programs (including this one) and (ii) the mutual use of the
information which has been exchanged, should contact IBM Corporation, Dept.
600A, Mail Drop 1329, Somers, NY 10589 USA.
Such information may be available, subject to appropriate terms and conditions,
including in some cases, payment of a fee.
The information contained in this document has not been submitted to any
formal IBM test and is distributed AS IS. The use of this information or the
implementation of any of these techniques is a customer responsibility and
depends on the customer′s ability to evaluate and integrate them into the
customer′s operational environment. While each item may have been reviewed
by IBM for accuracy in a specific situation, there is no guarantee that the same
or similar results will be obtained elsewhere. Customers attempting to adapt
these techniques to their own environments do so at their own risk.
Reference to PTF numbers that have not been released through the normal
distribution process does not imply general availability. The purpose of
including these reference numbers is to alert IBM customers to specific
information relative to the implementation of the PTF when it becomes available
to each customer according to the normal IBM PTF distribution process.
The following terms are trademarks of the International Business Machines
Corporation in the United States and/or other countries:
IBM
 Copyright IBM Corp. 1996
281
This soft copy for use by IBM employees only.
The following terms are trademarks of other companies:
C-bus is a trademark of Corollary, Inc.
PC Direct is a trademark of Ziff Communications Company and is
used by IBM Corporation under license.
UNIX is a registered trademark in the United States and other
countries licensed exclusively through X/Open Company Limited.
Microsoft, Windows, and the Windows 95 logo
are trademarks or registered trademarks of Microsoft Corporation.
Java and HotJava are trademarks of Sun Microsystems, Inc.
Other trademarks are trademarks of their respective companies.
282
SP PD Guide
This soft copy for use by IBM employees only.
Appendix E. Related Publications
The publications listed in this section are considered particularly suitable for a
more detailed discussion of the topics covered in this redbook.
E.1 International Technical Support Organization Publications
For information on ordering these ITSO publications see “How To Get ITSO
Redbooks” on page 285.
•
PSSP 2.1 Technical Presentation , SG24-4542
•
RS/6000 SP System Management: Easy, Lean, and Mean , GG24-2563
E.2 Redbooks on CD-ROMs
Redbooks are also available on CD-ROMs. Order a subscription and receive
updates 2-4 times a year at significant savings.
CD-ROM Title
System/390 Redbooks Collection
Networking and Systems Management Redbooks Collection
Transaction Processing and Data Management Redbook
AS/400 Redbooks Collection
RISC System/6000 Redbooks Collection (HTML, BkMgr)
RISC System/6000 Redbooks Collection (PostScript)
Application Development Redbooks Collection
Personal Systems Redbooks Collection
Subscription
Number
SBOF-7201
SBOF-7370
SBOF-7240
SBOF-7270
SBOF-7230
SBOF-7205
SBOF-7290
SBOF-7250
Collection Kit
Number
SK2T-2177
SK2T-6022
SK2T-8038
SK2T-2849
SK2T-8040
SK2T-8041
SK2T-8037
SK2T-8042
E.3 Other Publications
These publications are also relevant as further information sources:
 Copyright IBM Corp. 1996
•
IBM RS/6000 SP Scalable POWERparallel Systems Administration Guide ,
GC23-3897
•
IBM RS/6000 SP Scalable POWERparallel Systems Command and Technical
Reference , GC23-3900
•
IBM RS/6000 SP Scalable POWERparallel Systems Installation Guide ,
GC23-3898
•
IBM RS/6000 SP Scalable POWERparallel Systems Diagnosis and Messages
Guide , GC23-3899
•
NIM Installation Guide , SC23-2627
283
This soft copy for use by IBM employees only.
284
SP PD Guide
This soft copy for use by IBM employees only.
How To Get ITSO Redbooks
This section explains how both customers and IBM employees can find out about ITSO redbooks, CD-ROMs,
workshops, and residencies. A form for ordering books and CD-ROMs is also provided.
This information was current at the time of publication, but is continually subject to change. The latest
information may be found at URL http://www.redbooks.ibm.com.
How IBM Employees Can Get ITSO Redbooks
Employees may request ITSO deliverables (redbooks, BookManager BOOKs, and CD-ROMs) and information about
redbooks, workshops, and residencies in the following ways:
•
PUBORDER — to order hardcopies in United States
•
GOPHER link to the Internet - type GOPHER.WTSCPOK.ITSO.IBM.COM
•
Tools disks
To get LIST3820s of redbooks, type one of the following commands:
TOOLS SENDTO EHONE4 TOOLS2 REDPRINT GET SG24xxxx PACKAGE
TOOLS SENDTO CANVM2 TOOLS REDPRINT GET SG24xxxx PACKAGE (Canadian users only)
To get lists of redbooks:
TOOLS SENDTO WTSCPOK TOOLS REDBOOKS GET REDBOOKS CATALOG
TOOLS SENDTO USDIST MKTTOOLS MKTTOOLS GET ITSOCAT TXT
TOOLS SENDTO USDIST MKTTOOLS MKTTOOLS GET LISTSERV PACKAGE
To register for information on workshops, residencies, and redbooks:
TOOLS SENDTO WTSCPOK TOOLS ZDISK GET ITSOREGI 1996
For a list of product area specialists in the ITSO:
TOOLS SENDTO WTSCPOK TOOLS ZDISK GET ORGCARD PACKAGE
•
Redbooks Home Page on the World Wide Web
http://w3.itso.ibm.com/redbooks
•
IBM Direct Publications Catalog on the World Wide Web
http://www.elink.ibmlink.ibm.com/pbl/pbl
IBM employees may obtain LIST3820s of redbooks from this page.
•
REDBOOKS category on INEWS
•
Online — send orders to: USIB6FPL at IBMMAIL or DKIBMBSH at IBMMAIL
•
Internet Listserver
With an Internet E-mail address, anyone can subscribe to an IBM Announcement Listserver. To initiate the
service, send an E-mail note to announce@webster.ibmlink.ibm.com with the keyword subscribe in the body of
the note (leave the subject line blank). A category form and detailed instructions will be sent to you.
 Copyright IBM Corp. 1996
285
This soft copy for use by IBM employees only.
How Customers Can Get ITSO Redbooks
Customers may request ITSO deliverables (redbooks, BookManager BOOKs, and CD-ROMs) and information about
redbooks, workshops, and residencies in the following ways:
•
Online Orders (Do not send credit card information over the Internet) — send orders to:
In United States:
In Canada:
Outside North America:
•
•
United States (toll free)
Canada (toll free)
1-800-879-2755
1-800-IBM-4YOU
Outside North America
(+45) 4810-1320 - Danish
(+45) 4810-1420 - Dutch
(+45) 4810-1540 - English
(+45) 4810-1670 - Finnish
(+45) 4810-1220 - French
(long
(+45)
(+45)
(+45)
(+45)
(+45)
distance charges apply)
4810-1020 - German
4810-1620 - Italian
4810-1270 - Norwegian
4810-1120 - Spanish
4810-1170 - Swedish
Mail Orders — send orders to:
I B M Publications
144-4th Avenue, S.W.
Calgary, Alberta T2P 3N5
Canada
IBM Direct Services
Sortemosevej 21
DK-3450 Allerød
Denmark
Fax — send orders to:
United States (toll free)
Canada
Outside North America
•
Internet
usib6fpl@ibmmail.com
lmannix@vnet.ibm.com
bookshop@dk.ibm.com
Telephone orders
I B M Publications
Publications Customer Support
P.O. Box 29570
Raleigh, NC 27626-0570
USA
•
IBMMAIL
usib6fpl at ibmmail
caibmbkz at ibmmail
dkibmbsh at ibmmail
1-800-445-9269
1-403-267-4455
(+45) 48 14 2207
(long distance charge)
1-800-IBM-4FAX (United States) or (+1) 415 855 43 29 (Outside USA) — ask for:
Index # 4421 Abstracts of new redbooks
Index # 4422 IBM redbooks
Index # 4420 Redbooks for last six months
•
Direct Services - send note to softwareshop@vnet.ibm.com
•
On the World Wide Web
Redbooks Home Page
IBM Direct Publications Catalog
•
http://www.redbooks.ibm.com
http://www.elink.ibmlink.ibm.com/pbl/pbl
Internet Listserver
With an Internet E-mail address, anyone can subscribe to an IBM Announcement Listserver. To initiate the
service, send an E-mail note to announce@webster.ibmlink.ibm.com with the keyword subscribe in the body of
the note (leave the subject line blank).
286
SP PD Guide
This soft copy for use by IBM employees only.
IBM Redbook Order Form
Please send me the following:
Title
Order Number
Quantity
• Please put me on the mailing list for updated versions of the IBM Redbook Catalog.
First name
Last name
Company
Address
City
Postal code
Telephone number
Telefax number
•
Invoice to customer number
•
Credit card number
Credit card expiration date
Card issued to
Country
VAT number
Signature
We accept American Express, Diners, Eurocard, Master Card, and Visa. Payment by credit card not
available in all countries. Signature mandatory for credit card payment.
DO NOT SEND CREDIT CARD INFORMATION OVER THE INTERNET.
How To Get ITSO Redbooks
287
This soft copy for use by IBM employees only.
288
SP PD Guide
This soft copy for use by IBM employees only.
List of Abbreviations
ACL
Access Control List
MIB
AIX
Advanced Interactive
Executive
Management Information
Base
MPI
Message Passing Interface
MPL
Message Passing Library
MPP
Massively Parallel Processors
NIM
Network Installation Manager
NSB
Node Switch Board
NSC
Node Switch Chip
OID
Object ID
ODM
Object Data Manager
PE
Parallel Environment
PID
Process ID
PROFS
Professional Office System
PSSP
Parallel System Support
Program
PTC
Prepare to Commit
RAM
Random Access Memory
RCP
Remote Copy Protocol
RPQ
Request for Product
Quotation
RVSD
Recoverable Virtual Shared
Disk
SDR
System Data Repository
SMP
Symmetric Multiprocessors
SNMP
System Network Management
Protocol
SRC
System Resource Controller
SSI
Single System Image
TCP/IP
Transmission Control Protocol
/ Internet Protocol
API
Application Programming
Interface
BIS
Boot-Install Server
BSD
Berkeley Software
Distribution
CPU
Central Processing Unit
CRC
Cyclic Redundant Code
CSS
Communication Subsystem
CWS
Control Workstation
EDC
Error Detection Code
EPROM
Erasable Programmable Read
Only Memory
FIFO
First In - First Out
hb
heartbeat
HiPS
High Performance Switch
hrd
host respond daemon
HSD
Hashed Shared Disk
IBM
International Business
Machines Corporation
IP
Internet Protocol
ISB
Intermediate Switch Board
ISC
Intermediate Switch Chip
ITSO
International Technical
Support Organization
JFS
Journal File System
LAN
Local Area Network
LCD
Liquid Crystal Display
LED
Light Emitter Diode
TOD
Time of Day
LRU
Least Recently Used
UDP
User Datagram Protocol
LSC
Link Switch Chip
VSD
Virtual Shared Disk
LVM
Logical Volume Manager
VSM
Visual System Management
 Copyright IBM Corp. 1996
289
This soft copy for use by IBM employees only.
290
SP PD Guide
This soft copy for use by IBM employees only.
Index
Special Characters
.rhosts file
71
A
abbreviations 289
acronyms 289
addresses, TCP/IP 14
AFS authentication 17
See also Authentication Services
alias, TCP/IP 138
A M D 217
See also User Management
Authentication Services
.rhosts file 71
commands 71, 80
Daemons 75
Database 76
database, how to recreate 85
diagnosing 28
Files 77
Log files 79
lpps 74
Overview 71
Problems 82
removing configuration files 41
setup_authent script 229
Terminology 72
Version 4 17
B
behaviors, node 103
bibliography 283
Booting Process 195
LED codes 260-262 197
bos.sysmgt_aid 205
bos.sysmgt.serv_aid 159
C
CDE
See Common Desktop Environment
clock files 102
clock subsystem 100, 101
Coexistence, Switch 91
Common Desktop Environment 9
Comparing, switch 91
Configuration Files
syslogd files 189
Connecting 2
Control Workstation
Connecting the Frame 1
disk space requirements 11
 Copyright IBM Corp. 1996
Control Workstation (continued)
General Description 1
maximum number of processes
number of license users 14
preparing for install 8
prerequisites 10
required steps 8
serial line diagnostics 11
Supported RS/6000 as 1
switch log files 113
verify interfaces 13
crash command 208, 210
crontab 169
css_dump command 115
14
D
debugging NIM 60
delta replacement 20
diagnosing an installation
DISPLAY variable 36
DIX 20
dtprofile file 9
66
E
Eannotator command 97, 104
Eclock command 106
Efence command 106
Engineering and Scientific Subroutines Library
support on PSSP 2.1 19
errclear command 159
errdead command 159
errlogger command 159
errmsg command 159
errnotify object class 182
Error Log 124
Error Logging
AIX Error Log Facility 164
Archiving 170
Commands 161
detecting module string 162
Diagram 160
entry 160
Error Daemons 187
Install and Configure 163
Notification 175
Notification Object Class 180
Overview 159
templates 165
Viewing 170
error special file 162
errpt 115, 124
errpt command 35, 159, 174
291
This soft copy for use by IBM employees only.
errstop command 161
ESSL
See Engineering and Scientific Subroutines Library
Estart command 105, 114
Estart_sw script 108
Etopology command 105
Eunfence command 106
export problems 55
jm_config file
157
K
Kerberos
See Authentication Services
L
F
File Collection
See User Management
Fixdist 20
Fixdist on the Web 20
Fixdist, servers 21
Frame
Connecting the Control Workstation
Description 2
Frame Supervisor Card 2
listing frame information 34
fs_dump command 116
full replacement 20
1
G
GUI
See System Monitor
H
HACWS
See High Availability Control Workstation
hardmon daemon 2, 32
hb on debug mode 156
hb subsystem 155
heartbeat 151
Heartbeat packages 2
High Availability Control Workstation 2
High Performance Switch
See Switch
HiPS
See Switch
hmcmds command 32
host table 12
host_responds 151
hr subsystem 155
I
Improvements, switch 92
initialization, switch 108
install_cw script 236
See also PSSP Scripts
iotcl system call 162
ISB 96
See also Switch
Isolating problems 195
292
J
SP PD Guide
LED Codes
LED code 0c0 205
LED code 0c2 205
LED code 0c4 205
LED code 0c5 205
LED code 0c7 206
LED code 0c8 206
LED code 0c9 205
LED code 231 67
LED code 239 67
LED code 260 67
LED code 607 62
LED code 608 62
LED code 609 62
LED code 610 62
LED code 611 62
LED Code 612 62
LED code 888 154, 205
LED code u73 69
LED codes 231-239 197
LED codes 610-612 197
Log Files
daemon.stderr file 115
daemon.stdout file 115
directory structure 4
dtbx_failed.trace file 115
dtbx.trace file 115
flt file 114, 119
fs_daemon_print.file 114
log daemon dies 37
logging problems 37
out.top file 114, 116
rc.switch.log file 114
SPdaemon.log file 35
switch 113
log files, switch 113
lslpp command 23, 137
lslpp command, examples 25
lsnim command 48
M
maximum number of processes
MIT Version 4
See Authentication Services
mksysb image 20
14
This soft copy for use by IBM employees only.
N
network booting 61
Network Installation Management
attributes 49
bos.sysmgt.nim 10
commands 48
concepts 44
debugging 60
diagnosing an installation 66
export problems 55
host.info examples 65
lsnim command 48
nim command 48, 50
nimclient command 48
nimconfig command 48
niminit command 49
objects 45
operations 51
problems with 44
resource allocation 48
unconfigure 53
Network Options, no
See Tunable Values
NIM
See Network Installation Management
nim command 48, 50
nimclient command 48
nimconfig command 48
niminit command 49
no commands
See Tunable Values
node_number 43
Nodes
customization problems 69
installation problems 66
Node Supervisor Card 2
p r i m a r y 103
primary backup 103
secondary node 104
switch log files 113
Notification facility, error log 175
NSB 96
See also Switch
NTP 213
See also User Management
NVRAM 131, 162
P
Parallel Environment
support on PSSP 2.1 19
Partitioning 18
See also System Partitioning
Partitions
See System Partitioning
PATH environment variable 40
PATH environment variable for PSSP
8
PEND, error type 180
penotify command 179
Perf, error type 180
PERL
See Practical Extraction and Report Language
PERM, error type 180
Phase-Locked Loops 101
PLL
See Phase-Locked Loops
POE
See Parallel Environment
POWERparallel System Support Programs
changes from 1.2 to 2.1 19
Installing 7
PATH environment variable 8, 40
PTF 10 220
PTF 11 91
PTF 12 29
PTF set 11 28
PTFs 20
requirements 16
ssp.basic 90, 126, 214
ssp.css 90
ssp.sysman 162, 214
ssp.top 126, 130
verifying installation 33
Version 1.2 18
Version 2.1 18
Practical Extraction and Report Language
Debugging 124
preparing the CW for install 8
primary backup 103
primary node 103
Problem Determination 4
processes, switch 110
PSSP
See POWERparallel System Support Programs
PSSP Scripts
Debugging 124
Estart_sw script 108
install_cw diagnosing 29
install_cw script 42
install_cw, ODM node_number 43
post_process script 29
post_sysctl script 29
problems with install_cw 30
pssp_script 47
rc.switch script 108
script.cust script 47
setup_authent, APAR IX56801 26
setup_authent, diagnosing 28
setup_server fails 56
setup_server script 48
tuning.cust script 47
PTF 20
PTF 10 220
PTF 11 27, 91
Index
293
This soft copy for use by IBM employees only.
PTF 12 29, 69
PTFs, how to get them 21
PVMe
support on PSSP 2.1 19
R
rc.boot script 62
rc.switch script 108
See also PSSP Scripts
rc.switch script 262
recovery from a switch failure 104
Resource Manager 157
RPQ 130
RS-232
See Serial Link
RS/6000 SP
authentication 17
Control Workstation 1
directory structure for /spdata 15
Ethernet 2
Hardware and Software 1
Serial Link 2
SP Ethernet 1
S
SDR
See System Data Repository
secondary node 104
Serial Link
diagnostics 11
verifying connection 34
setup_authent script 229
See also PSSP Scripts
setup_server script 239
See also PSSP Scripts
snap command 207
software level, how to determine
SP
See RS/6000 SP
SP Ethernet 2
SP Log Files
See Log Files
SP Monitor
See System Monitor
SP Switch
See Switch
SP_NAME 136, 146, 191
spbootins command 61
splm command 172
splogd daemon 191
spmkuser command 217
spmon
See System Monitor
ssp.authent 74
ssp.basic 74, 90, 126, 214
ssp.css 90
294
SP PD Guide
22
ssp.sysman 162, 214
ssp.top 126, 130
Supervisor Card 2
supper
See User Management
Switch
128-way system, example 89
48-way system, example 90
Clock files 102
Coexistence 91
Comparing 91
css_dump command 115
daemon.stderr file 115
daemon.stdout file 115
Description 3
dtbx_failed.trace file 115
dtbx.trace file 115
Eannotator 97
Eannotator command 104
Eclock command 106
Efence command 106
Estart command 105
Estart_sw script 108
Etopology command 105
Eunfence command 106
flt file 114, 119
fs_daemon_print.file 114
fs_dump command 116
HiPS 127
HiPS 3.0 87
HiPS Board 93
HiPS Clock Subsystem 100
Improvements 92
Initialization 108
intermedia switch board 88
ISB 96
log files 113
Logical Notation 99
node switch board 88
NSB 96
out.top file 114, 116
Overview 87
partitioning 4
primary backup node 103
primary node 103
processes 110
rc.switch script 108
rc.switch.log file 114
rc.switch script 262
recovery from a failure 104
secondary node 104
Software Overview 90
SP Switch Board 95
SP Switch Clock Subsystem 101
ssp.basic 90
ssp.css 90
switch responds 111
Topology 131
This soft copy for use by IBM employees only.
Switch (continued)
Topology file, example 97
Topology file, nomenclature 99
topology files 4, 95
Worm daemon 110
Switch Problems 199
switch responds 111
sysdumpdev command 203
sysdumpstart command 205
syslog 165
syslog reports 165
syslogd daemon 188
System Data Repository
Archiving 140
Daemons 145
default partition 146
Directory structure 148
host responds 2
Partitions directory 134
primary partition 146
Restoring 144
Structure 271
switch responds 111
System Dump
Copying 206
Handling 201
How to start 204
Primary Dump Device 202
Secondary Dump Device 203
Sending 208
System Monitor
GUI, problems with 36
hmcmds command 32
problem starting 38
problems with 31
problems with pull down menus 33
Snapshot of 31
System Monitor Problems 197
System Partitioning
Applying 144
Archiving the SDR 140
default 146
Directory 134
example 128
Limitations 127
Overview 125
partition name 141
p r i m a r y 146
Process Overview 139
Restoring the SDR 144
Rules 126
Scope 125
SDR daemons 145
SP_NAME 136
Switch Topology 131
Verifying 142
System Partitioning Problems 200
T
TBS
See Switch
TEMP, error type 180
templates, error log 165
Time of the Day 91, 109
TOD
See Time of the Day
Topology File
Description 95
Example 97
initialization 109
Logical Notation 99
Nomenclature 99
Switch 131
Trusted Computing Base (TCB)
Tunable Values
tunables values 15
tunable values, network 15
46
U
UNKN, error type 180
User Management
Adding an SP user 216
a m d 221
amd hints 222
Components 214
File Collections 218
Login Control 218
NTP 225
Overview 213
Print Services 225
supper hints 219
users, license 14
V
VFS 202
Virtual Shared Disks
Improvement on PSSP 2.1 19
VPD 160
VSD 127, 144, 151, 157
See also Virtual Shared Disks
W
Worm 110
Worm daemon
137
Index