square_d_m5dsfs030_8536_sco3

square_d_m5dsfs030_8536_sco3
Type S Contactors and Starters
Class 8536/8502/8736/8702/8810/8811/8812
CONTENTS
Description
Page
Magnetic Contactors and Starters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Reversing Magnetic Starters and Contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
Motor Starters Multi-Speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39
Contents
SECTION 1 – MAGNETIC CONTACTORS AND STARTERS
Application Data – Class 8502, 8536 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
Selection – Class 8502 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7
Selection – Class 8536 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-12
Application Data – Class 8502, 8536 . . . . . . . . . . . . . . . . . . . . . . . . . . 13-16
Approximate Dimensions, Shipping Weights – Class 8502, 8536 . . . . 17-22
Application Data – Class 8502 Vacuum Contactors. . . . . . . . . . . . . . . . . . 23
Selection and Pricing – Class 8502 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
1
5/98
© 1998 Square D All Rights Reserved
Full Voltage Contactors and Starters — NEMA
Application Data – Class 8502, 8536
Type SCO2
Size 1, 3-Pole Contactor
Type SCO3
Size 1, 3-Pole Starter
AC MAGNETIC CONTACTORS
CLASS 8502
AC MAGNETIC STARTERS
CLASS 8536
General Information
General Information
Class 8502 Type S magnetic contactors are used
to switch heating loads, capacitors, transformers,
and electric motors where overload protection is
separately provided. Class 8502 contactors are
available in NEMA Sizes 00-7. Type S contactors
are designed for operation at 600 Volts, AC 50-60
Hertz.
Class 8536 Type S magnetic starters are used for
full voltage starting and stopping AC squirrel cage
motors. Motor overload protection is provided by
melting alloy type thermal overload relays. Class
8536 starters are available in NEMA Sizes 00-7.
Type S starters are designed for operation at 600
Volts AC, 50-60 Hertz.
Holding Circuit Contact
Holding Circuit Contact
A normally open holding circuit contact for three
wire control is provided on all contactors as
standard. Sizes 00-2 contactors use a Class 9999
SX11 auxiliary contact as the holding circuit
contact. Sizes 3-7 contactors use a Class 9999
SX6 auxiliary contact as the holding circuit
contact. See Class 9999 for the holding circuit
contact electrical ratings. On Size 00-1 single
phase contactors, a power pole is used as the
holding circuit contact and therefore has the same
rating as the power contacts.
A normally open holding circuit contact for three
wire control is provided on all contactors as
standard. Sizes 00-2 contactors use a Class 9999
SX11 auxiliary contact as the holding circuit
contact. Sizes 3-7 contactors use a Class 9999
SX6 auxiliary contact as the holding circuit
contact. See Class 9999 for the holding circuit
contact electrical ratings.
Enclosures
Class 8502 magnetic contactors are available in
the following enclosures:
Starter with MOTOR LOGIC
• NEMA Type 1 General Purpose
• NEMA Type 4 & 4X Watertight and Dusttight
Stainless Steel
• NEMA Type 4X Watertight, Dusttight, and
Corrosion Resistant Glass — Polyester
• NEMA Type 7 & 9 Bolted and Spin-Top for
Hazardous Locations
• NEMA Type 12 Dusttight and Driptight for
Industrial Use
The NEMA Type 4 & 4X stainless steel enclosure
(Sizes 0-5) has a brushed finish. For an
electropolished finish, specify Form G16 and add
15% to the price of the standard device.
Also, NEMA Type 12 devices are available UL
Listed for use in Class II, Division 2, Group G and
Class III, Divisions 1 and 2 locations. Request
Form G21, no additional charge.
Starter with Melting Alloy
Separate enclosures are available, see Class
9991.
Overload Relays with Melting Alloys
Class 8536 Type S Sizes 00-6 starters are
provided with a melting alloy thermal overload
relay as standard. Interchangeable thermal units
are available in standard trip (Class 20) Sizes
00-6, quick trip (Class 10) Sizes 00-4, and slow
trip (Class 30) Sizes 00-3. Single-phase starters
use one thermal unit, 3-phase starters use three
thermal units.
Class 8536 Size 7 starters are provided with solid
state Motor Logic which has selectable trip
Class10/20, Ground fault detection, and
Communication capabilities for future
enhancement. The solid state overload relay is
ambient insensitive and features phase loss,
phase unbalance and over-current protection.
MOTOR LOGIC™ Solid State Overload Relay
(SSOLR)
Solid state overload relays are available for Sizes
00 – 7 starters. These ambient insensitive
overload relays provide phase loss protection,
phase unbalance protection and a LED power
indicator. For additional information, see the Class
9065 catalog section. To order Type S starters
with solid state overload relays, see Factory
Modification (FORMS).
Bimetallic overload relays are also available for
Sizes 0-6. Ambient Compensated and Noncompensated versions are supplied with manual
2
© 1998 Square D All Rights Reserved
5/98
Full Voltage Contactors and Starters — NEMA
Application Data – Class 8502, 8536
and automatic reset, trip current adjustment, and
an alarm contact on Sizes 0-2. For additional
information, see the Class 9065 catalog section.
To order Type S starters with bimetallic overload
relays, see Factory Modifications (FORMS).
Enclosures
Class 8536 magnetic starters are available in the
following enclosures.
• NEMA Type 1 General Purpose Enclosure
• NEMA Type 3R Rainproof, Sleet Resistant for
Outdoor Use
• NEMA Type 4 & 4X Watertight and Dusttight
• NEMA Type 4X Watertight, Dusttight, and
Corrosion Resistant Glass – Polyester
• NEMA Type 7 & 9 Bolted and Spin-Top for
Hazardous Locations
• NEMA Type 9 Bolted for Hazardous Locations
• NEMA Type 12 Dusttight and Driptight for
Industrial Use
The NEMA Type 4 & 4X stainless steel enclosure
(Sizes 0-5) has a brushed finish. For an
electropolished finish, specify Form G16 and add
15% to the price of the standard device. Sizes 6 &
7 are painted sheet steel and are rated NEMA 4
ONLY.
Also NEMA Type 12 devices are available UL
Listed for use in Class II, Division 2, Group G and
Class III, Divisions 1 and 2 locations. Specify
Form G21, no additional charge.
Coil Voltages
AC coils are available for application on 50-60
Hertz. NEMA Sizes 00-5 are supplied with coils
that are designed to operate satisfactorily on line
voltages of 85% – 110% of rated voltage. NEMA
Size 6 and 7 contactors are supplied with a DC
coil operated by a solid state rectifier circuit that is
powered by an AC source.
Please note that Voltage Codes have been
added to the Type designations in order to
improve customer service. It is necessary to
include the Voltage Code when ordering
contactors and starters. Also, 120 Volt Polyphase
contactors and starters will be wired for separate
control.
Auxiliary Contacts
Additional auxiliary contacts may be added to
Type S contactors. See Page 15 for maximum
number of auxiliary units and Form designations
for factory installed auxiliary contacts.
Type S Accessories
Additional accessories such as power poles,
pneumatic timer attachments, and cover mounted
control stations are available as factory or field
modifications.
Separate enclosures are available, see Class
9991.
3
5/98
© 1998 Square D All Rights Reserved
Full Voltage Contactors — NEMA
Selection – Class 8502
3-Pole Polyphase — 600 Volts AC Maximum — 50-60 Hertz
Continuous
Current
Ratings
Motor Volts
00
9
Separate Controlj
200
230
460
575
0
18
1
2
NEMA
Size
Type SC02
Size 1, 3-Pole Contactor
Max. HP
t
Coil Voltage
Open Type
NEMA Type 1
General
Purpose
Enclosure
NEMA Type 4 & 4X
Watertight, Dusttight
Brushed Stainless
Steel Enclosure
(Size 0-5)f
Type
Type
Type
11⁄2
11⁄2
2
2
120
208
240
480
600
SAO12V02S
SAO12V08
SAO12V03
SAO12V06
SAO12V07
SAG12V02S
SAG12V08
SAG12V03
SAG12V06
SAG12V07
USE Size 0
Separate Controlj
200
230
460
575
3
3
5
5
120
208
240
480
600
SBO2V02S
SBO2V08
SBO2V03
SBO2V06
SBO2V07
SBG2V02S
SBG2V08
SBG2V03
SBG2V06
SBG2V07
SBW12V02S
SBW12V08
SBW12V03
SBW12V06
SBW12V07
27
Separate Controlj
200
230
460
575
71⁄2
71⁄2
10
10
120
208
240
480
600
SCO2V02S
SCO2V08
SCO2V03
SCO2V06
SCO2V07
SCG2V02S
SCG2V08
SCG2V03
SCG2V06
SCG2V07
SCW12V02S
SCW12V08
SCW12V03
SCW12V06
SCW12V07
45
Separate Controlj
200
230
460
575
10
15
25
25
120
208
240
480
600
SDO2V02S
SDO2V08
SDO2V03
SDO2V06
SDO2V07
SDG2V02S
SDG2V08
SDG2V03
SDG2V06
SDG2V07
SDW12V02S
SDW12V08
SDW12V03
SDW12V06
SDW12V07
3
90
Separate Controlj
200
230
460
575
25
30
50
50
120
208
240
480
600
SEO2V02S
SEO2V08
SEO2V03
SEO2V06
SEO2V07
SEG2V02S
SEG2V08
SEG2V03
SEG2V06
SEG2V07
SEW12V02S
SEW12V08
SEW12V03
SEW12V06
SEW12V07
4
135
Separate Controlj
200
230
460
575
40
50
100
100
120
208
240
480
600
SFO2V02S
SFO2V08
SFO2V03
SFO2V06
SFO2V07
SFG2V02S
SFG2V08
SFG2V03
SFG2V06
SFG2V07
SFW12V02S
SFW12V08
SFW12V03
SFW12V06
SFW12V07
5
270
Separate Controlj
200
230
460
575
75
100
200
200
120
208
240
480
600
SGO2V02S
SGO2V08
SGO2V03
SGO2V06
SGO2V07
SGG2V02S
SGG2V08
SGG2V03
SGG2V06
SGG2V07
SGW12V02S
SGW12V08
SGW12V03
SGW12V06
SGW12V07
6
540
Separate Controlj
200
230
460
575
150
200
400
400
120
208
240
480
600
SHO2V02S
SHO2V08
SHO2V03
SHO2V06
SHO2V07
SHG2V02S
SHG2V08
SHG2V03
SHG2V06
SHG2V07
SHW12V02S
SHW12V08
SHW12V03
SHW12V06
SHW12V07
810
Separate Controlj
200
230
460
575
...
300
600
600
120
208
240
480
600
SJO2V02S
SJO2V08
SJO2V03
SJO2V06
SJO2V07
SJG2V02S
SJG2V08
SJG2V03
SJG2V06
SJG2V07
SJW12V02S
SJW12V08
SJW12V03
SJW12V06
SJW12V07
7
f
j
t
Size 6 and 7 are painted sheet steel rated NEMA Type 4 only.
120 Volt Polyphase contactors are wired for separate control.
Coil voltage code must be specified to order this product. Refer to standard voltage codes listed below and insert as shown in How to Order.
Coil Voltage Codes
Voltage
Code
File E78351
CCN NLDX
File LR12751
Class 3211-04
60 Hz
50 Hz
24q
120
208
240
480
600
Specify
...
110
...
220
440
550
Specify
q
VO1
VO2
VO8
VO3
VO6
VO7
V99
24 V coils are not available on Sizes 4-7. On Sizes 00-3, where 24 V
coils are available, Form S (separate control) must be specified.
How to Order:
To Order Specify:
File 60905
Class 3211-04
IEC 947-4-1
Sizes 00-5 only
• Class Number
• Type Number
• Coil Voltage Code
• Form(s)
Catalog Number
Class
Type
Coil
Voltage
Code
Form(s)
8502
SBG2
VO2
P1S
Factory Modifications (FORMS) ...............Refer to Catalog 9999CT9701
Application Data ................................................................... Pages 13-16
Dimensions ........................................................................... Pages 17-20
Separate Enclosures (Class 9991) ...........Refer to Catalog 9999CT9701
Replacement Parts (Class 9998) ..............Refer to Catalog 9999CT9701
Type S Accessories (Class 9999) .............Refer to Catalog 9999CT9701
4
© 1998 Square D All Rights Reserved
5/98
Full Voltage Contactors — NEMA
Selection – Class 8502
3-Pole Polyphase — 600 Volts AC Maximum — 50-60 Hertz
Continuous
Current
Ratings
NEMA
Size
Motor
Volts
Max.
HP
t
Coil
Voltage
NEMA Type 4X
Watertight, Dusttight,
Corrosion-Resistant
Glass-Polyester
Enclosure
NEMA Type 7 & 9
Hazardous Locations
Class I, Groups C & D
Class II, Groups E, F, & G
Bolted Type
Type
Cast Ironc
Cast
Aluminum
NEMA Type 12
Dusttight & Driptight
Industrial Use Enclosure
SPIN TOP ®
Type
Type
Use Size 0
Use Size 0
00
9
Separate Controlj
200
11⁄2
230
11⁄2
460
2
575
2
120
208
240
480
600
Use Size 0
Use Size 0
0
18
Separate Controlj
200
3
230
3
460
5
575
5
120
208
240
480
600
SBW22V02S
SBW22V08
SBW22V03
SBW22V06
SBW22V07
SBT2V02S
SBT2V08
SBT2V03
SBT2V06
SBT2V07
SBT42V02S
SBT42V08
SBT42V03
SBT42V06
SBT42V07
SBR2V02S
SBR2V08
SBR2V03
SBR2V06
SBR2V07
SBA2V02S
SBA2V08
SBA2V03
SBA2V06
SBA2V07
1
27
Separate Controlj
200
71⁄2
230
71⁄2
460
10
575
10
120
208
240
480
600
SCW22V02S
SCW22V08
SCW22V03
SCW22V06
SCW22V07
SCT2V02S
SCT2V08
SCT2V03
SCT2V06
SCT2V07
SCT42V02S
SCT42V08
SCT42V03
SCT42V06
SCT42V07
SCR2V02S
SCR2V08
SCR2V03
SCR2V06
SCR2V07
SCA2V02S
SCA2V08
SCA2V03
SCA2V06
SCA2V07
2
45
Separate Controlj
200
10
230
15
460
25
575
25
120
208
240
480
600
SDW22V02S
SDW22V08
SDW22V03
SDW22V06
SDW22V07
SDT2V02S
SDT2V08
SDT2V03
SDT2V06
SDT2V07
SDT42V02S
SDT42V08
SDT42V03
SDT42V06
SDT42V07
SDR2V02S
SDR2V08
SDR2V03
SDR2V06
SDR2V07
SDA2V02S
SDA2V08
SDA2V03
SDA2V06
SDA2V07
3
90
Separate Controlj
200
25
230
30
460
50
575
50
120
208
240
480
600
SEW22V02S
SEW22V08
SEW22V03
SEW22V06
SEW22V07
...
SET42V02S
SET42V08
SET42V03
SET42V06
SET42V07
SER2V02S
SER2V08
SER2V03
SER2V06
SER2V07
SEA2V02S
SEA2V08
SEA2V03
SEA2V06
SEA2V07
4
135
Separate Controlj
200
40
230
50
460
100
575
100
120
208
240
480
600
SFW22V02S
SFW22V08
SFW22V03
SFW22V06
SFW22V07
...
SFT42V02S
SFT42V08
SFT42V03
SFT42V06
SFT42V07
SFR2V02S
SFR2V08
SFR2V03
SFR2V06
SFR2V07
SFA2V02S
SFA2V08
SFA2V03
SFA2V06
SFA2V07
5
270
Separate Controlj
200
75
230
100
460
200
575
200
120
208
240
480
600
...
...
...
SGR2V02S
SGR2V08
SGR2V03
SGR2V06
SGR2V07
SGA2V02S
SGA2V08
SGA2V03
SGA2V06
SGA2V07
6
540
Separate Controlj
200
150
230
200
460
400
575
400
120
208
240
480
600
...
...
...
...
SHA2V02S
SHA2V08
SHA2V03
SHA2V06
SHA2V07
7
810
Separate Controlj
200
—
230
300
460
600
575
600
208
240
480
600
...
...
...
...
SJA2V02S
SJA2V08
SJA2V03
SJA2V06
SJA2V07
j
c
t
120 Volt Polyphase contactors are wired for separate control.
Limited to one Pilot Light and a Selector Switch or Start-Stop Push Button.
Coil voltage code must be specified to order this product. Refer to standard coil voltage codes listed in selection table above or additional standard voltage codes below and insert as shown
in the HOW TO ORDER block.
Coil Voltage Codes
Explosion Proof Units
Voltage
File E78503
CCN NPKR
Code
60 Hz
50 Hz
24q
120
208
240
480
600
Specify
...
110
...
220
440
550
Specify
q
VO1
VO2
VO8
VO3
VO6
VO7
V99
File LR60905
Class 3218-03
24 V coils are not available on Sizes 4-7. On Sizes 00-3, where 24 V
coils are available, Form S (separate control) must be specified.
How to Order:
To Order Specify:
Factory Modifications (FORMS) ............... Refer to Catalog 9999CT9701
Application Data .................................................................... Pages 13-16
Dimensions ............................................................................ Pages 17-20
Separate Enclosures (Class 9991) ........... Refer to Catalog 9999CT9701
Replacement Parts (Class 9998) .............. Refer to Catalog 9999CT9701
Type S Accessories (Class 9999) ............ Refer to Catalog 9999CT9701
• Class Number
• Type Number
• Coil Voltage Code
• Form(s)
Catalog Number
Class
Type
Coil
Voltage
Code
Form(s)
8502
SBA2
VO2
P1S
5
5/98
© 1998 Square D All Rights Reserved
Full Voltage Contactors — NEMA
Selection – Class 8502
600 Volts AC Maximum — 50-60 Hertz
NEMA
Size
Continuous
Current
Ratings
Motor Volts
Max. HP
t
Coil Voltage
Open Type
NEMA Type 1
General
Purpose
Enclosure
Type
Type
NEMA Type 4 & 4X
Watertight, Dusttight
Brushed Stainless
Steel Enclosure
(Size 0-5)f
Type
1-Pole Single Phase
0
18
1
27
115
230
115
230
1
2
2
3
120
240
120
240
SBO5V02
SBO5V03
SCO5V02
SCO5V03
SBG5V02
SBG5V03
SCG5V02
SCG5V03
SBW15V02
SBW15V03
SCW15V02
SCW15V03
1⁄3
120
240
120
240
120
240
120
240
120
240
120
240
120
240
120
240
120
240
SAO11V02
SAO11V03
SBO1V02
SBO1V03
SCO1V02
SCO1V03
SDO1V02
SDO1V03
SEO1V02
SEO1V03
SFO1V02
SFO1V03
SGO1V02
SGO1V03
SHO1V02
SHO1V03
SJO1V02
SJO1V03
SAG11V02
SAG11V03
SBG1V02
SBG1V03
SCG1V02
SCG1V03
SDG1V02
SDG1V03
SEG1V02
SEG1V03
SFG1V02
SFG1V03
SGG1V02
SGG1V03
SHG1V02
SHG1V03
SJG1V02
SJG1V03
Use Size 0
120
208
240
480
600
120
208
240
480
600
120
208
240
480
600
120
208
240
480
600
120
208
240
480
600
SBO3V02S
SBO3V08
SBO3V03
SBO3V06
SBO3V07
SCO3V02S
SCO3V08
SCO3V03
SCO3V06
SCO3V07
SDO3V02S
SDO3V08
SDO3V03
SDO3V06
SDO3V07
SEO3V02S
SEO3V08
SEO3V03
SEO3V06
SEO3V07
SFO3V02S
SFO3V08
SFO3V03
SFO3V06
SFO3V07
SBG3V02S
SBG3V08
SBG3V03
SBG3V06
SBG3V07
SCG3V02S
SCG3V08
SCG3V03
SCG3V06
SCG3V07
SDG3V02S
SDG3V08
SDG3V03
SDG3V06
SDG3V07
SEG3V02S
SEG3V08
SEG3V03
SEG3V06
SEG3V07
SFG3V02S
SFG3V08
SFG3V03
SFG3V06
SFG3V07
SBW13V02S
SBW13V08
SBW13V03
SBW13V06
SBW13V07
SCW13V02S
SCW13V08
SCW13V03
SCW13V06
SCW13V07
SDW13V02S
SDW13V08
SDW13V03
SDW13V06
SDW13V07
SEW13V02S
SEW13V08
SEW13V03
SEW13V06
SEW13V07
SFW13V02S
SFW13V08
SFW13V03
SFW13V06
SFW13V07
2-Pole Single Phase
00
9
0
18
1
27
2
45
115
230
115
230
115
230
115
230
3
90
...
...
4
135
...
...
5
270
...
...
6
540
...
...
7
810
...
...
1
1
2
2
3
3
71⁄2
SBW11V02
SBW11V03
SCW11V02
SCW11V03
SDW11V02
SDW11V03
SEW11V02
SEW11V03
SFW11V02
SFW11V03
SGW11V02
SGW11V03
SHW1V02
SHW1V03
SJW1V02
SJW1V03
4-Pole Polyphase
0
18
1
27
2
45
3
90
4
135
Separate Controlj
200
230
460
575
Separate Controlj
200
230
460
575
Separate Controlj
200
230
460
575
Separate Controlj
200
230
460
575
Separate Controlj
200
230
460
575
3
3
5
5
71⁄2
71⁄2
10
10
10
15
25
25
25
30
50
50
40
50
100
100
5-Pole Polyphase
0
1
2
3
4
f
j
t
Separate Controlj
120
SBO4V02S
SBG4V02S
SBW14V02S
200
3
208
SBO4V08
SBG4V08
SBW14V08
230
3
240
SBO4V03
SBG4V03
SBW14V03
460
5
480
SBO4V06
SBG4V06
SBW14V06
575
5
600
SBO4V07
SBG4V07
SBW14V07
Separate Controlj
120
SCO4V02S
SCG4V02S
SCW14V02S
1
200
7 ⁄2
208
SCO4V08
SCG4V08
SCW14V08
27
230
71⁄2
240
SCO4V03
SCG4V03
SCW14V03
460
10
480
SCO4V06
SCG4V06
SCW14V06
575
10
600
SCO4V07
SCG4V07
SCW14V07
Separate Controlj
120
SDO4V02S
SDG4V02S
SDW14V02S
200
10
208
SDO4V08
SDG4V08
SDW14V08
45
230
15
240
SDO4V03
SDG4V03
SDW14V03
460
25
480
SDO4V06
SDG4V06
SDW14V06
575
25
600
SDO4V07
SDG4V07
SDW14V07
Separate Controlj
120
SEO4V02S
SEG4V02S
SEW14V02S
200
25
208
SEO4V08
SEG4V08
SEW14V08
90
230
30
240
SEO4V03
SEG4V03
SEW14V03
460
50
480
SEO4V06
SEG4V06
SEW14V06
575
50
600
SEO4V07
SEG4V07
SEW14V07
Separate Controlj
120
SFO4V02S
SFG4V02S
SFW14V02S
200
40
208
SFO4V08
SFG4V08
SFW14V08
135
230
50
240
SFO4V03
SFG4V03
SFW14V03
460
100
480
SFO4V06
SFG4V06
SFW14V06
575
100
600
SFO4V07
SFG4V07
SFW14V07
Size 6 and 7 are painted sheet steel rated NEMA Type 4 only.
120 Volt Polyphase contactors are wired for separate control.
Coil voltage code must be specified to order this product. Refer to standard voltage codes listed in selection table above or additional standard
voltage codes and insert as shown in the HOW TO ORDER block on Page 5.
18
6
© 1998 Square D All Rights Reserved
5/98
Full Voltage Contactors — NEMA
Selection – Class 8502
600 Volts AC Maximum — 50-60 Hertz
NEMA
Size
Continuous
Current
Ratings
Motor
Volts
Max.
HP
t
Coil
Voltage
NEMA Type 4X
Watertight, Dusttight,
Corrosion-Resistant
Glass-Polyester
Enclosure
NEMA Type 7 & 9
Hazardous Locations
Class I, Groups C & D
Class II, Groups E, F, & G
Bolted Type
Type
Cast Ironc
Cast
Aluminum
...
SBT5V02
SBT5V03
SCT5V02
SCT5V03
SBT45V02
SBT45V03
SCT5V02
SCT5V03
NEMA Type 12
Dusttight & Driptight
Industrial Use Enclosure
SPIN TOP ®
Type
Type
SBR5V02
SBR5V03
SCR5V02
SCR5V03
SBA5V02
SBA5V03
SCA5V02
SCA5V03
1-Pole Single Phase
0
18
1
27
115
230
115
230
1
2
2
3
120
240
120
240
1/3
1
1
2
2
3
3
71⁄2
120
240
120
240
120
240
120
240
120
240
120
240
120
240
120
240
120
240
Use Size 0
Use Size 0
SBW21V02
SBW21V03
SCW21V02
SCW21V03
SDW21V02
SDW21V03
Consult Local Square D
Field Office
Consult Local Square D
Field Office
SBT1V02
SBT1V03
SCT1V02
SCT1V03
SDT1V02
SDT1V03
120
208
240
480
600
120
208
240
480
600
120
208
240
480
600
120
208
240
480
600
120
208
240
480
600
...
2-Pole Single Phase
0
18
1
27
2
45
115
230
115
230
115
230
115
230
3
90
...
...
4
135
...
...
5
270
...
...
6
540
...
...
7
810
...
...
00
9
Use Size 0
Use Size 0
...
SBT41V02
SBT41V03
SCT41V02
SCT41V03
SDT41V02
SDT41V03
SET41V02
SET41V03
SFT41V02
SFT41V03
...
...
...
SBR1V02
SBR1V03
SCR1V02
SCR1V03
SDR1V02
SDR1V03
SER1V02
SER1V03
SFR1V02
SFR1V03
SGR1V02
SGR1V03
...
...
...
...
...
...
...
...
SBA1V02
SBA1V03
SCA1V02
SCA1V03
SDA1V02
SDA1V03
SEA1V02
SEA1V03
SFA1V02
SFA1V03
SGA1V02
SGA1V03
SHA1V02
SHA1V03
SJA1V02
SJA1V03
SBW33V02S
SBW33V08
SBW33V03
SBW33V06
SBW33V07
SCW23V02S
SCW23V08
SCW23V03
SCW23V06
SCW23V07
SDW23V02S
SDW23V08
SDW23V03
SDW23V06
SDW23V07
SBT3V02S
SBT3V08
SBT3V03
SBT3V06
SBT3V07
SCT3V02S
SCT3V08
SCT3V03
SCT3V06
SCT3V07
SDT3V02S
SDT3V08
SDT3V03
SDT3V06
SDT3V07
Consult Local Square D
Field Office
Consult
Local Square D
Field Office
Consult
Local Square D
Field Office
Consult Local Square D
Field Office
Consult
Local Square D
Field Office
Consult
Local Square D
Field Office
SBR3V02S
SBR3V08
SBR3V03
SBR3V06
SBR3V07
SCR3V02S
SCR3V08
SCR3V03
SCR3V06
SCR3V07
SDR3V02S
SDR3V08
SDR3V03
SDR3V06
SDR3V07
SER3V02S
SER3V08
SER3V03
SER3V06
SER3V07
SFR3V02S
SFR3V08
SFR3V03
SFR3V06
SFR3V07
SBA3V02S
SBA3V08
SBA3V03
SBA3V06
SBA3V07
SCA3V02S
SCA3V08
SCA3V03
SCA3V06
SCA3V07
SDA3V02S
SDA3V08
SDA3V03
SDA3V06
SDA3V07
SEA3V02S
SEA3V08
SEA3V03
SEA3V06
SEA3V07
SFA3V02S
SFA3V08
SFA3V03
SFA3V06
SFA3V07
...
4-Pole Polyphase
0
18
1
27
2
45
3
90
4
135
Separate Controlj
200
3
230
3
460
5
575
5
Separate Controlj
200
71⁄2
230
71⁄2
460
10
575
19
Separate Controlj
200
10
230
15
460
25
575
25
Separate Controlj
200
25
230
30
460
50
575
50
Separate Controlj
200
40
230
50
460
100
575
100
Consult
Local Square D
Field Office
Consult
Local Square D
Field Office
Consult
Local Square D
Field Office
5-Pole Polyphase
0
1
2
3
4
j
c
t
Separate Controlj
120
SBA4V02S
200
3
208
SBA4V08
Consult Local Square D
230
3
240
...
...
...
SBA4V03
Field Office
460
5
480
SBA4V06
575
5
600
SBA4V07
Separate Controlj
120
SCA4V02S
1
208
SCA4V08
200
7 ⁄2
Consult Local Square D
230
71⁄2
240
SCA4V03
27
...
...
...
Field Office
460
10
480
SCA4V06
575
10
600
SCA4V07
Separate Controlj
120
SDA4V02S
200
10
208
SDA4V08
Consult Local Square D
45
230
15
240
...
...
...
SDA4V03
Field Office
460
25
480
SDA4V06
575
25
600
SDA4V07
Separate Controlj
120
SEA4V02S
200
25
208
SEA4V08
Consult Local Square D
90
230
30
240
...
...
...
SEA4V03
Field Office
460
50
480
SEA4V06
575
50
600
SEA4V07
Separate Controlj
120
SFA4V02S
200
40
208
SFA4V08
Consult Local Square D
135
230
50
240
...
...
...
SFA4V03
Field Office
460
100
480
SFA4V06
575
100
600
SFA4V07
120 Volt Polyphase contactors are wired for separate control.
Limited to one Pilot Light and a Selector Switch or Start-Stop Push Button.
Coil voltage code must be specified to order this product. Refer to standard coil voltage codes listed in selection table above or additional standard voltage codes and insert as shown in
the HOW TO ORDER block on Page 5.
18
7
5/98
© 1998 Square D All Rights Reserved
Full Voltage Starters — NEMA
Selection – Class 8536
3-Pole Polyphase—600 Volt AC Max. 50/60 Hz—Three Thermal Units Required
Continuous
Motor
NEMA
Current
Volts
Size
Ratings
Max.
HP
Open
t
Type
Coil
Voltage
Type
00
0
1
2
3
4
5
6
7
f
j
t
NEMA Type 1
General
Purpose
Enclosure
Type
NEMA Type 4 & 4X
Watertight, Dusttight
Brushed Stainless
Steel Enclosure
(Size 0-5)f
Type
NEMA Type 4X
Watertight, Dusttight,
Corrosion-Resistant
Glass-Polyester
Enclosure
Type
Separate Controlj 120
SAO12V02S
SAG12V02S
200
11⁄2
208
SAO12V08
SAG12V08
9
230
11⁄2
240
SAO12V03
SAG12V03
Use Size 0
Use Size 0
460
2
480
SAO12V06
SAG12V06
575
2
600
SAO12V07
SAG12V07
Separate Controlj 120
SBO2V02S
SBG2V02S
SBW12V02S
SBW22V02S
200
3
208
SBO2V08
SBG2V08
SBW12V08
SBW22V08
230
3
240
SBO2V03
SBG2V03
SBW12V03
SBW22V03
18
460
5
480
SBO2V06
SBG2V06
SBW12V06
SBW22V06
575
5
600
SBO2V07
SBG2V07
SBW12V07
SBW22V07
Separate Controlj 120
SCO3V02S
SCG3V02S
SCW13V02S
SCW23V02S
1
200
7 ⁄2
208
SCO3V08
SCG3V08
SCW13V08
SCW23V08
27
230
71⁄2
240
SCO3V03
SCG3V03
SCW13V03
SCW23V03
460
10
480
SCO3V06
SCG3V06
SCW13V06
SCW23V06
575
10
600
SCO3V07
SCG3V07
SCW13V07
SCW23V07
Separate Controlj 120
SDO1V02S
SDG1V02S
SDW11V02S
SDW21V02S
200
10
208
SDO1V08
SDG1V08
SDW11V08
SDW21V08
45
230
15
240
SDO1V03
SDG1V03
SDW11V03
SDW21V03
460
25
480
SDO1V06
SDG1V06
SDW11V06
SDW21V06
575
25
600
SDO1V07
SDG1V07
SDW11V07
SDW21V07
Separate Controlj 120
SEO1V02S
SEG1V02S
SEW11V02S
SEW21V02S
200
25
208
SEO1V08
SEG1V08
SEW11V08
SEW21V08
90
230
30
240
SEO1V03
SEG1V03
SEW11V03
SEW21V03
460
50
480
SEO1V06
SEG1V06
SEW11V06
SEW21V06
575
50
600
SEO1V07
SEG1V07
SEW11V07
SEW21V07
Separate Controlj 120
SFO1V02S
SFG1V02S
SFW11V02S
SFW21V02S
200
40
208
SFO1V08
SFG1V08
SFW11V08
SFW21V08
135
230
50
240
SFO1V03
SFG1V03
SFW11V03
SFW21V03
460
100
480
SFO1V06
SFG1V06
SFW11V06
SFW21V06
575
100
600
SFO1V07
SFG1V07
SFW11V07
SFW21V07
Separate Controlj 120
SGO1V02S
SGG1V02S
SGW11V02S
200
75
208
SGO1V08
SGG1V08
SGW11V08
270
230
100
240
SGO1V03
SGG1V03
SGW11V03
...
460
200
480
SGO1V06
SGG1V06
SGW11V06
575
200
600
SGO1V07
SGG1V07
SGW11V07
Separate Controlj 120
SHO2V02S
SHG2V02S
SHW2V02S
200
150
208
SHO2V08
SHG2V08
SHW2V08
540
230
200
240
SHO2V03
SHG2V03
SHW2V03
...
460
400
480
SHO2V06
SHG2V06
SHW2V06
575
400
600
SHO2V07
SHG2V07
SHW2V07
Separate Controlj 120
SJO2V02S
SJG2V02S
SJW2V02S
200
—
208
SJO2V08
SJG2V08
SJW2V08
810
230
300
240
SJO2V03
SJG2V03
SJW2V03
...
460
600
480
SJO2V06
SJG2V06
SJW2V06
575
600
600
SJO2V07
SJG2V07
SJW2V07
Size 6 and 7 are rated NEMA Type 4 only.
120 Volt Polyphase starters are wired for separate control.
Coil voltage code must be specified to order this product. Refer to standard coil voltage codes listed in selection table above or additional standard
voltage codes below and insert as shown in the HOW TO ORDER block.
Coil Voltage Codes
Voltage
Code
60 Hz
50 Hz
24q
120
208
240
480
600
Specify
...
110
...
220
440
550
Specify
q
File E78351
CCN NLDX
File LR60905
Class 3211-04
IEC 947-4-1
Sizes 00-5 only
VO1
VO2
VO8
VO3
VO6
VO7
V99
24 V coils are not available on Sizes 4-7. On Sizes 00-3, where 24 V
coils are available, Form S (separate control) must be specified.
How to Order:
To Order Specify:
• Class Number
• Type Number
• Coil Voltage Code
• Form(s)
Catalog Number
Class
Type
Coil
Voltage
Code
Form(s)
8536
SBA2
VO2
P1S
Factory Modifications (FORMS) ...............Refer to Catalog 9999CT9701
Application Data ................................................................... Pages 13-16
Dimensions ........................................................................... Pages 17-20
Separate Enclosures (Class 9991) ...........Refer to Catalog 9999CT9701
Replacement Parts (Class 9998) ..............Refer to Catalog 9999CT9701
Type S Accessories (Class 9999) .............Refer to Catalog 9999CT9701
8
© 1998 Square D All Rights Reserved
5/98
Full Voltage Starters — NEMA
Selection – Class 8536
3-Pole Polyphase — 600 Volts AC Maximum — 50-60 Hertz—Three Thermal Units Required
Continuous
Current
Ratings
NEMA
Size
Motor
Volts
Max.
HP
t
Coil
Voltage
NEMA Type 12/3Rk
NEMA Type 9
Dusttight & Driptight
Hazardous Locations
Industrial Use
Class II, Groups E, F, & G
Enclosure
NEMA Type 7 & 9
Hazardous Locations
Class I, Groups C & D
Class II, Class E, F, & G
Bolted Type
Cast Ironc
Type
Type
USE Size 0
USE Size 0
Use Size 0
00
9
0
18
Separate Controlj
200
3
230
3
460
5
575
5
120
208
240
480
600
SBT2V02S
SBT2V08
SBT2V03
SBT2V06
SBT2V07
SBT42V02S
SBT42V08
SBT42V03
SBT42V06
SBT42V07
SBR2V02S
SBR2V08
SBR2V03
SBR2V06
SBR2V07
SBE2V02S
SBE2V08
SBE2V03
SBE2V06
SBE2V07
SBA2V02S
SBA2V08
SBA2V03
SBA2V06
SBA2V07
1
27
Separate Controlj
200
71⁄2
230
71⁄2
460
10
575
10
120
208
240
480
600
SCT3V02S
SCT3V08
SCT3V03
SCT3V06
SCT3V07
SCT43V02S
SCT43V08
SCT43V03
SCT43V06
SCT43V07
SCR3V02S
SCR3V08
SCR3V03
SCR3V06
SCR3V07
SCE3V02S
SCE3V08
SCE3V03
SCE3V06
SCE3V07
SCA3V02S
SCA3V08
SCA3V03
SCA3V06
SCA3V07
2
45
Separate Controlj
200
10
230
15
460
25
575
25
120
208
240
480
600
SDT1V02S
SDT1V08
SDT1V03
SDT1V06
SDT1V07
SDT41V02S
SDT41V08
SDT41V03
SDT41V06
SDT41V07
SDR1V02S
SDR1V08
SDR1V03
SDR1V06
SDR1V07
SDE1V02S
SDE1V08
SDE1V03
SDE1V06
SDE1V07
SDA1V02S
SDA1V08
SDA1V03
SDA1V06
SDA1V07
3
90
Separate Controlj
200
25
230
30
460
50
575
50
120
208
240
480
600
...
SET43V02S
SET43V08
SET43V03
SET43V06
SET43V07
SER3V02S
SER3V08
SER3V03
SER3V06
SER3V07
SEE1V02S
SEE1V08
SEE1V03
SEE1V06
SEE1V07
SEA1V02S
SEA1V08
SEA1V03
SEA1V06
SEA1V07
4
135
Separate Controlj
200
40
230
50
460
100
575
100
120
208
240
480
600
...
SFT41V02S
SFT41V08
SFT41V03
SFT41V06
SFT41V07
SFR1V02S
SFR1V08
SFR1V03
SFR1V06
SFR1V07
SFE1V02S
SFE1V08
SFE1V03
SFE1V06
SFE1V07
SFA1V02S
SFA1V08
SFA1V03
SFA1V06
SFA1V07
5
270
Separate Controlj
200
75
230
100
460
200
575
200
120
208
240
480
600
...
SGT41V02S
SGT41V08
SGT41V03
SGT41V06
SGT41V07
SGR1V02S
SGR1V08
SGR1V03
SGR1V06
SGR1V07
SGE1V02S
SGE1V08
SGE1V03
SGE1V06
SGE1V07
SGA1V02S
SGA1V08
SGA1V03
SGA1V06
SGA1V07
6
540
Separate Controlj
200
150
230
200
460
400
575
400
120
208
240
480
600
...
...
...
...
SHA2V02S
SHA2V08
SHA2V03
SHA2V06
SHA2V07
810
Separate Controlj
200
—
230
300
460
600
575
600
120
208
240
480
600
...
SJA2V02S
SJA2V08
SJA2V03
SJA2V06
SJA2V07
k
j
c
t
USE Size 0
SPIN TOP®
Type
Separate Controlj
200
11⁄2
230
11⁄2
460
2
575
2
7
120
208
240
480
600
Cast
Aluminum
...
...
...
For NEMA Type 3R enclosed devices (Sizes 0-4 only), change “A” in Type designation to “H”, no additional charge. Consult Factory for restrictions on available Forms in NEMA Type 3R
enclosures.
120 Volt Polyphase starters are wired for separate control.
Limited to one Pilot Light and a Selector Switch or Start-Stop Push Button.
Coil voltage code must be specified to order this product. Refer to standard coil voltage codes listed in selection table above or additional standard voltage codes in table below and insert
as shown in the HOW TO ORDER block.
Coil Voltage Codes
Voltage
Code
60 Hz
50 Hz
24q
120
208
240
480
600
Specify
...
110
...
220
440
550
Specify
q
VO1
VO2
VO8
VO3
VO6
VO7
V99
24 V coils are not available on Sizes 4-7. On Sizes 00-3, where 24 V
coils are available, Form S (separate control) must be specified.
Factory Modifications (FORMS)............... Refer to Catalog 9999CT9701
Application Data.................................................................... Pages 13-16
Dimensions............................................................................ Pages 17-20
Separate Enclosures (Class 9991)........... Refer to Catalog 9999CT9701
Replacement Parts (Class 9998).............. Refer to Catalog 9999CT9701
Type S Accessories (Class 9999) ............ Refer to Catalog 9999CT9701
How to Order:
To Order Specify:
• Class Number
• Type Number
• Coil Voltage Code
• Form(s)
Catalog Number
Class
Type
Coil
Voltage
Code
Form(s)
8536
SBA2
VO2
H3O
9
5/98
© 1998 Square D All Rights Reserved
Full Voltage Starters — NEMA
Selection – Class 8536
2-Pole Single Phase — 600 Volts AC Maximum — 50-60 Hertz Thermal Units —
One Thermal Unit Required
Continuous
Motor
NEMA
Current
Volts
Size
Ratings
00
9
0
18
1
27
1P
36
2
45
Max.
HP
1⁄3
115
230
115
230
115
230
115
230
115
230
Open
t
Type
Coil
Voltage
120
240
120
240
120
240
120
240
120
240
1
1
2
2
3
3
5
3
71⁄2
NEMA Type 1
General
Purpose
Enclosure
Type
Type
SAO11V02
SAO11V03
SBO1V02
SBO1V03
SCO1V02
SCO1V03
SCO2V02
SCO2V03
SDO6V02
SDO6V03
SAG11V02
SAG11V03
SBG1V02
SBG1V03
SCG1V02
SCG1V03
SCG2V02
SCG2V03
SDG6V02
SDG6V03
NEMA Type 4X
NEMA Type 4 & 4X
Watertight, Dusttight,
Watertight, Dusttight
Corrosion-Resistant
Brushed Stainless
Glass-Polyester
Steel Enclosure
Enclosure
Type
Type
Use Size 0
Use Size 0
SBW11V02
SBW11V03
SCW11V02
SCW11V03
SCW12V02
SCW12V03
SDW16V02
SDW16V03
SBW21V02
SBW21V03
SCW21V02
SCW21V03
SCW22V02
SCW22V03
SDW26V02
SDW26V03
4-Pole, 2-Phase — 600 Volts AC Maximum — 50-60 Hertz — Two Thermal Units Required
Continuous
Motor
NEMA
Current
Volts
Size
Ratings
Max.
HP
Open
t
Type
Coil
Voltage
Type
0
1
2
3
4
j
t
NEMA Type 1
General
Purpose
Enclosure
Type
NEMA Type 4X
NEMA Type 4 & 4X
Watertight, Dusttight,
Watertight, Dusttight
Corrosion-Resistant
Brushed Stainless
Glass-Polyester
Steel Enclosure
Enclosure
Type
Type
Separate Controlj 120
SBO3V02S SBG3V02S
SBW13V02S
SBW23V02S
200
3
208
SBO3V08
SBG3V08
SBW13V08
SBW23V08
230
3
240
SBO3V03
SBG3V03
SBW13V03
SBW23V03
18
460
10
480
SBO3V06
SBG3V06
SBW13V06
SBW23V06
575
10
600
SBO3V07
SBG3V07
SBW13V07
SBW23V07
Separate Controlj 120
SCO4V02S SCG4V02S
SCW14V02S
SCW24V02S
200
71⁄2
208
SCO4V08
SCG4V08
SCW14V08
SCW24V08
27
230
71⁄2
240
SCO4V03
SCG4V03
SCW14V03
SCW24V03
460
10
480
SCO4V06
SCG4V06
SCW14V06
SCW24V06
575
10
600
SCO4V07
SCG4V07
SCW14V07
SCW24V07
Separate Controlj 120
SDO2V02S SDG2V02S
SDW12V02S
SDW22V02S
200
10
208
SDO2V08
SDG2V08
SDW12V08
SDW22V08
230
15
240
SDO2V03
SDG2V03
SDW12V03
SDW22V03
45
460
25
480
SDO2V06
SDG2V06
SDW12V06
SDW22V06
575
25
600
SDO2V07
SDG2V07
SDW12V07
SDW22V07
Separate Controlj 120
SEO2V02S SEG2V02S
SEW12V02S
200
15
208
SEO2V08
SEG2V08
SEW12V08
90
230
30
240
SEO2V03
SEG2V03
SEW12V03
460
50
480
SEO2V06
SEG2V06
SEW12V06
575
50
600
SEO2V07
SEG2V07
SEW12V07
Consult Local Square D
Field Office
Separate Controlj 120
SFO2V02S SFG2V02S
SFW12V02S
200
40
208
SFO2V08
SFG2V08
SFW12V08
135
230
50
240
SFO2V03
SFG2V03
SFW12V03
460
100
480
SFO2V06
SFG2V06
SFW12V06
575
100
600
SFO2V07
SFG2V07
SFW12V07
120 Volt Polyphase starters are wired for separate control.
Coil voltage code must be specified to order this product. Refer to standard coil voltage codes listed in selection table above or additional standard
voltage codes below and insert as shown in the HOW TO ORDER block.
Coil Voltage Codes
Voltage
Code
60 Hz
50 Hz
24q
120
208
240
480
600
Specify
...
110
...
220
440
550
Specify
q
File E78351
CCN NLDX
VO1
VO2
VO8
VO3
VO6
VO7
V99
24 V coils are not available on Sizes 4-7. On Sizes 00-3, where 24 V
coils are available, Form S (separate control) must be specified.
How to Order:
To Order Specify:
File LR60905
Class 3211-04
IEC 947-4-1
• Class Number
• Type Number
• Coil Voltage Code
• Form(s)
Catalog Number
Class
Type
Coil
Voltage
Code
Form(s)
8536
SCG1
VO2
P1
Factory Modifications (FORMS) ...............Refer to Catalog 9999CT9701
Application Data ................................................................... Pages 13-16
Dimensions ........................................................................... Pages 17-20
Separate Enclosures (Class 9991) ...........Refer to Catalog 9999CT9701
Replacement Parts (Class 9998) ..............Refer to Catalog 9999CT9701
Type S Accessories (Class 9999) .............Refer to Catalog 9999CT9701
10
© 1998 Square D All Rights Reserved
5/98
Full Voltage Starters — NEMA
Selection – Class 8536
2-Pole Single Phase — 600 Volts AC Maximum — 50-60 Hertz — One Thermal Unit Required
Devices require 1 thermal unit
Continuous
Current
Ratings
NEMA
Size
00
115
230
115
230
115
230
115
230
115
230
9
0
18
1
27
1P
36
2
45
Motor
Volts
Max.
HP
1⁄3
t
Coil
Voltage
120
240
120
240
120
240
120
240
120
240
1
1
2
2
3
3
5
3
71⁄2
NEMA Type 7 & 9
Hazardous Locations
Class I, Groups C & D
Class II, Groups E, F, & G
Bolted Type
Cast
Cast Ironc
Aluminum
USE Size 0
SBT1V02
SBT1V03
SCT1V02
SCT1V03
SCT2V02
SCT2V03
SDT6V02
SDT6V03
SBT1V02
SBT1V03
SCT1V02
SCT1V03
SCT2V02
SCT2V03
SDT6V02
SDT6V03
NEMA Type 12/3Rf
NEMA Type 9
Dusttight & Driptight
Hazardous Locations
Industrial Use
Class II, Groups E, F, & G
Enclosure
SPIN TOP®
Type
Type
USE Size 0
USE Size 0
Use Size 0
SBR1V02
SBR1V03
SCR1V02
SCR1V03
SCR2V02
SCR2V03
SDR6V02
SDR6V03
SBE1V02
SBE1V03
SCE1V02
SCE1V03
SCE2V02
SCE2V03
SDE6V02
SDE6V03
SBA1V02
SBA1V03
SCA1V02
SCA1V03
SCA2V02
SCA2V03
SDA6V02
SDA6V03
Type
4-Pole 2-Phase — 600 Volts AC Maximum — 50-60 Hertz —Two Thermal Units Required
Continuous
Current
Ratings
NEMA
Size
0
1
2
3
4
j
f
c
t
Motor
Volts
Max.
HP
t
Coil
Voltage
NEMA Type 7 & 9
Hazardous Locations
Class I, Groups C & D
Class II, Groups E, F, & G
Bolted Type
Cast
Cast Ironc
Aluminum
NEMA Type 12
NEMA Type 9
Dusttight & Driptight
Hazardous Locations
Industrial Use
Class II, Groups E, F, & G
Enclosure
SPIN TOP®
Type
Type
Type
Separate Controlj
120
SBT3V02S
SBR3V02S
SBA3V02S
Consult Local
200
3
208
SBT3V08
SBR3V08
SBA3V08
Square D
...
230
3
240
SBT3V03
SBR3V03
SBA3V03
460
5
480
SBT3V06
SBR3V06
SBA3V06
Field Office
575
5
600
SBT3V07
SBR3V07
SBA3V07
Separate Controlj
120
SCT4V02S
SCR4V02S
SCA4V02S
Consult Local
208
SCT4V08
SCR4V08
SCA4V08
200
71⁄2
240
SCT4V03
SCR4V03
SCA4V03
230
71⁄2
27
Square D
...
460
10
480
SCT4V06
SCR4V06
SCA4V06
Field Office
575
10
600
SCT4V07
SCR4V07
SCA4V07
Separate Controlj
120
SDT2V02S
SDR2V02S
SDA2V02S
Consult
Local
200
10
208
SDT2V08
SDR2V08
SDA2V08
45
Square D
...
230
15
240
SDT2V03
SDR2V03
SDA2V03
460
25
480
SDT2V06
SDR2V06
SDA2V06
Field Office
575
25
600
SDT2V07
SDR2V07
SDA2V07
Separate Controlj
120
SER2V02S
SEA2V02S
Consult Local
Consult Local
200
25
208
SER2V08
SEA2V08
90
Square D
Square D
...
230
30
240
SER2V03
SEA2V03
460
50
480
SER2V06
SEA2V06
Field Office
Field Office
575
50
600
SER2V07
SEA2V07
Separate Controlj
120
SFA2V02S
Consult Local
Consult Local
200
40
208
SFA2V08
135
Square D
Square D
...
...
230
50
240
SFA2V03
460
100
480
SFA2V06
Field Office
Field Office
575
100
600
SFA2V07
120 Volt Polyphase contactors are wired for separate control.
For NEMA Type 3R enclosed devices (2-Pole only), change ‘A’ in Type designation to ‘H’, no additional charge.
Limited to one Pilot Light and Selector Switch or Start-Stop Push Button.
Coil voltage code must be specified to order this product. Refer to standard coil voltage codes listed in selection table above or additional standard voltage codes below and insert as shown
in the HOW TO ORDER block.
18
Coil Voltage Codes
Voltage
Code
60 Hz
50 Hz
24q
120
208
240
480
600
Specify
...
110
...
220
440
550
Specify
q
VO1
VO2
VO8
VO3
VO6
VO7
V99
24 V coils are not available on Sizes 4-7. On Sizes 00-3, where 24 V
coils are available, Form S (separate control) must be specified.
How to Order:
To Order Specify:
Factory Modifications (FORMS)............... Refer to Catalog 9999CT9701
Application Data.................................................................... Pages 13-16
Dimensions............................................................................ Pages 17-20
Separate Enclosures (Class 9991)........... Refer to Catalog 9999CT9701
Replacement Parts (Class 9998).............. Refer to Catalog 9999CT9701
Type S Accessories (Class 9999) ............ Refer to Catalog 9999CT9701
• Class Number
• Type Number
• Coil Voltage Code
• Form(s)
Catalog Number
Class
Type
Coil
Voltage
Code
Form(s)
8536
SCA1
VO3
P1
11
5/98
© 1998 Square D All Rights Reserved
Full Voltage Starters
Selection – Class 8536
Types SB-SD with Auxiliary Load Terminals – Class 8536
3-Pole Polyphase — Three Thermal Units Required
It is sometimes desirable to use the capacitors in motor branch circuits to improve power factor. The Size
0-2 Type SB-SD starters listed included three auxiliary terminals to allow easy connection of power
factor correction capacitors. When capacitors are connected using these terminals, no adjustment on
the selection of thermal units is necessary.
These terminals are also available as a kit Class 9999 Type PFL for Type S NEMA Size 0, 1 and 2
Starters with Motor Logic overload relays. These terminals are available for connection of power factor
(PF) correction capacitors. These kits are sold separately and are not factory installed.
NEMA Size
Motor Volts
Maximum HP
Coil Voltage
Open Type
0
Separate Controlj
200
230
460
575
3
3
5
5
120
208
240
480
600
SBTO2V02S
SBTO2V08
SBTO2V03
SBTO2V06
SBTO2V07
1
Separate Controlj
200
230
460
575
71⁄2
71⁄2
10
10
120
208
240
480
600
SBTO3V02S
SBTO3V08
SBTO3V03
SBTO3V06
SBTO3V07
2
Separate Controlj
200
230
460
575
10
15
25
25
120
208
240
480
600
SDTO1V02S
SDTO1V08
SDTO1V03
SDTO1V06
SDTO1V07
120 Volt polyphase starters are wired for separate control.
j
Extra Capacity Single Phase Starters
2-Pole Single Phase — 250 Volts AC Maximum — 50-60 Hertz
Thermal Units — Devices require 1 thermal unit. Standard trip.
t
Open
Type
NEMA Type 1
General Purpose
Enclosure
NEMA Type 3R
Rainproof, Sleet
Resistant, Outdoor
Use Enclosure
NEMA Type 4 & 4X
Watertight, Dusttight
Brushed Stainless Steel
Enclosure
(Sizes 0-5)
NEMA Type 4X
Watertight
Corrosion Resistant
Class-Polyester
Enclosure
NEMA Type 12
Dusttight & Driptight
Industrial Use
Enclosure
Motor
Volts
Max.
HP
Type
Type
Type
Type
Type
115
230
5
10
120
240
SDO8V02
SDO8V03
...
SDH8V02
SDH8V03
...
...
...
115
230
71⁄2
120
240
SEO6V02
SEO6V03
SEG6V02
SEG6V03
SEH6V02
SEH6V03
SEW16V02
SEW16V03
SEW26V02
SEW26V03
SEA6V02
SEA6V03
15
Coil
Voltage
Coil voltage code must be specified to order this product. Refer to standard coil voltage codes listed in selection tables above or additional standard voltage codes below and insert as
shown in the HOW TO ORDER bolck.
t
Coil Voltage Codes
Voltage
Code
60 Hz
50 Hz
24
120
208
240
480
600
Specify
...
110
...
220
440
550
Specify
VO1
VO2
VO8
VO3
VO6
VO7
V99
How to Order:
To Order Specify:
• Class Number
• Type Number
• Coil Voltage Code
• Form(s)
Catalog Number
Class
Type
Coil
Voltage
Code
Form(s)
8536
SEG6
VO3
P1
Factory Modifications (FORMS) ...............Refer to Catalog 9999CT9701
Application Data ................................................................... Pages 13-16
Dimensions ........................................................................... Pages 17-20
Separate Enclosures (Class 9991) ...........Refer to Catalog 9999CT9701
Replacement Parts (Class 9998) ..............Refer to Catalog 9999CT9701
Type S Accessories (Class 9999) .............Refer to Catalog 9999CT9701
12
© 1998 Square D All Rights Reserved
5/98
Full Voltage Contactors and Starters — NEMA
Application Data – Class 8502, 8536
NEMA Load
Size
Volts
Maximum
Horsepower
Rating –
Nonplugging
and
Nonjogging
Duty
Single PolyPhase Phase
KVA Rating for Switching
Transformer Primaries at 50 or 60
Cycles
Tungsten
Resistance
Maximum
Transformers
Transformers
and
Heating Loads,
Continuous Service –
Horsepower
Having Inrush
Having Inrush
Infrared
KW – Other
Current
Limit
Rating –
Currents (Worst Currents (Worst
Lamp
Than
Infrared
Rating,
Current
Plugging and
Case Peak) of
Case Peak) of
Load,
Lamp Loads
Amperes – Rating,
Jogging Duty j
Not More Than
Over 20 Through
Amperes –
u
600 Volt
Amperes
20 Times Peak of 40 Times Peak of
250 Volts
Max.
t
Continuous
Continuous
Max.
Current Rating
Current Rating
a
Single PolySingle PolySingle PolySingle PolyPhase Phase
Phase Phase Phase
Phase
Phase
Phase
3 Phase
Rating for
Switching
Capacitors
k
KVAR
1⁄2
115
...
...
...
9
11
5
...
...
...
...
...
...
...
200
...
11⁄2
...
...
9
11
5
...
...
...
...
...
...
...
1⁄2
230
1
1
.
.
.
.
.
.
9
11
5
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
..
00
380
...
11⁄2
...
...
9
11
...
...
...
...
...
...
...
...
460
...
2
...
...
9
11
...
...
...
...
...
...
...
...
575
...
2
...
...
9
11
...
...
...
...
...
...
...
...
1⁄2
...
18
21
10
...
...
0.6
...
0.3
...
...
115
1
...
1
18
21
10
...
...
...
1.8
...
0.9
...
200
...
3
...
1 ⁄2
18
21
10
...
...
1.2
2.1
0.6
1.0
...
230
2
3
1
11⁄2
0
18
21
...
...
...
...
...
...
...
...
380
...
5
...
11⁄2
460
...
5
...
2
18
21
...
...
...
2.4
4.2
1.2
2.1
...
575
...
5
...
2
18
21
...
...
...
3.0
5.2
1.5
2.6
...
115
2
...
1
...
27
32
15
3
5
1.2
...
0.6
...
...
200
...
71⁄2
...
3
27
32
15
...
9.1
...
3.6
...
1.8
...
2
3
27
32
15
6
10
2.4
4.3
1.2
2.1
...
230
3
71⁄2
1
380
...
10
...
5
27
32
...
...
16.5
...
...
...
...
...
460
...
10
...
5
27
32
...
12
20
4.9
8.5
2.5
4.3
...
575
...
10
...
5
27
32
...
15
25
6.2
11.0
3.1
5.3
...
...
36
42
24
...
...
...
...
...
...
...
115
3
...
11⁄2
1P
230
5
...
3
...
36
42
24
...
...
...
...
...
...
...
115
3
...
2
...
45
52
30
5
8.5
2.1
...
1.0
...
...
45
52
30
...
15.4
...
6.3
...
3.1
...
200
...
10
...
71⁄2
15
5
10
45
52
30
10
17
4.1
7.2
2.1
3.6
8
230
71⁄2
2
380
...
25
...
15
45
52
...
...
28
...
...
...
...
...
460
...
25
...
15
45
52
...
20
34
8.3
14
4.2
7.2
16
575
...
25
...
15
45
52
...
25
43
10.0
18
5.2
8.9
20
115
...
...
...
...
90
104
60
10
17
4.1
...
2.0
...
...
200
...
25
...
15
90
104
60
...
31
...
12
...
6.1
...
230
...
30
...
20
90
104
60
20
34
8.1
14
4.1
7.0
27
3
380
...
50
...
30
90
104
...
...
56
...
...
...
...
...
460
...
50
...
30
90
104
...
40
68
16
28
8.1
14
53
575
...
50
...
30
90
104
...
50
86
20
35
10
18
67
200
...
40
...
25
135
156
120
...
45
...
20
...
10
...
230
...
50
...
30
135
156
120
30
52
14
23
6.8
12
40
4
380
...
75
...
50
135
156
...
...
86.7
...
...
...
...
...
460
...
100
...
60
135
156
...
60
105
27
47
14
23
80
575
...
100
...
60
135
156
...
75
130
34
59
17
29
100
200
...
75
...
60
270
311
240
...
91
...
41
...
20
...
230
...
100
...
75
270
311
240
60
105
27
47
14
24
80
5
380
...
150
...
125
270
311
...
...
173
...
...
...
...
...
460
...
200
...
150
270
311
...
120
210
54
94
27
47
160
575
...
200
...
150
270
311
...
150
260
68
117
34
59
200
200
...
150
...
125
540
621
480
...
182
...
81
...
41
...
230
...
200
...
150
540
621
480
120
210
54
94
27
47
160
6f
380
...
300
...
250
540
621
...
...
342
...
...
...
...
...
460
...
400
...
300
540
621
...
240
415
108
188
54
94
320
575
...
400
...
300
540
621
...
300
515
135
234
68
117
400
230
...
300
...
...
810
932
...
180
315
...
...
...
...
240
7f
460
...
600
...
...
810
932
...
360
625
...
...
...
...
480
575
...
600
...
...
810
932
...
450
775
...
...
...
...
600
Tables and footnotes are taken from NEMA Standards.
j
Ratings shown are for applications requiring repeated interruptions of stalled motor current or repeated closing of high transient currents encountered in rapid motor reversal, involving more
than five openings or closings per minute and more than ten in a ten-minute period, such as plug-stop, plug-reverse or jogging duty. Ratings apply to single speed and multi-speed
controllers.
t
Per NEMA Standards paragraph ICS 2-321.20, the service-limit current represents the maximum ms current, in amperes, which the controller may be expected to carry for protracted periods
in normal service. At service-limit current ratings, temperature rises may exceed those obtained by testing the controller at its continuous current rating. The ultimate trip current of overcurrent (overload) relays or other motor protective devices shall not exceed the service-limit current ratings of the controller.
a FLUORESCENT LAMP LOADS – 300 VOLTS AND LESS – The characteristics of fluorescent lamps are such that it is not necessary to derate Class 8502 contactors below their normal
continuous current rating. Class 8903 contactors may also be used with fluorescent lamp loads. For controlling tungsten and infrared lamp loads, and resistance heating loads, Class 8903
ac lighting contactors are recommended. These contactors are specifically designed for such loads and are applied at their full rating as listed in the Class 8903 Section.
u
Ratings apply to contactors which are employed to switch the load at the utilization voltage of the heat producing element with a duty which requires continuous operation of not more than
five openings per minute. Class 8903 Types L and S lighting contactors are rated for resistance heating loads.
k
When discharged, a capacitor has essentially zero impedance. For repetitive switching by contactor, sufficient impedance should be connected in series to limit inrush current to not more
than 6 times the contactor rated continuous current. In many installations, the impedance of connecting conductors may be sufficient for this purpose. When switching to connect additional
banks, the banks already on the line may be charged and can supply additional available short-circuit current which should be considered when selecting the impedance to limit the current.
The ratings for capacitor switching above assume the following maximum available fault currents: NEMA Size 2-3: 5,000 A RMS Sym.; NEMA Size 4-5: 10,000 A RMS Sym.; NEMA Size
6-7: 18,000 A RMS Sym. If available fault current is greater than these values, connect sufficient impedance in series as noted in the previous paragraph.
f
See Page 16 regarding operation rates for Size 6 & 7.
The motor ratings in the above table are NEMA standard ratings and apply only when the code letter of the motor is the same as or occurs earlier in the alphabet than is shown in
the table below. Motors having code letters occurring later in the alphabet may require a larger controller. Consult local Square D field office.
Motor HP Rating
Maximum Allowable Motor
Code Letter
11⁄2-2
L
3-5
K
71⁄2 & above
H
13
5/98
© 1998 Square D All Rights Reserved
Full Voltage Contactors and Starters — NEMA
Application Data – Class 8502, 8536
CLASS 8502 AND 8536 APPLICATION
DATA
Power Contact Ratings
All contactors and starters are rated in
accordance with NEMA standards. The ratings
shown in the price tables are for normal service.
For complete data on power contact ratings, refer
to Page 13.
Maintenance of Equipment
Class 9998 Repair Parts Kits are available for all
Class 8502 contactors and Class 8536 starters.
Service bulletins with a complete list of replaceable
parts are supplied with all enclosed devices.
Separate bulletins can be ordered and are listed
along with the appropriate contact parts kit.
Device
Service
No. of
NEMA
Bulletin
Type Series
Poles
Type
Short Circuit Protection
00
According to the National Electrical Code branch
circuit overcurrent protection must be provided for
each contactor or starter. For starters refer to
instructions furnished with the thermal unit
selection table. For contactors (Class 8502 or
8702) provide branch circuit overcurrent
protection in accordance with the National
Electrical Code, except do not exceed the
maximum protective device ratings in table below.
Class
NEMA Maximum K5, RK5 or
Size
Voltage
RK1 Fuse
(Ampere)
00
0
1
2
3
4
5
6
7
t
600
250
600
250
600
250
600
250
600
250
600
600
600
600
Class L Fuse only.
10
12
20
25
30
40
60
100
125
200
400
600
600
Class
J or T
Fuse
(Ampere)
Inverse-Time
Circuit
Breaker
(Ampere)
15
15
30
60
100
200
400
600
1200t
1600t
20
35
40
60
80
90
125
150
225
400
800
1200
SA
Replacement
Contacts
Class 9998 Type
A
2-3
362AS
SL2
B
2-3
556AS
SJ1
0
SB
A&B
1-3
4
5
SL2
277AS
SL12
277AS & 250AS (1)SL12 & (1)SL22
277AS & 250AS or
(1)SL2 & (2)SL22
1
SC
A&B
1-3
4
5
SL3
278AS
SL13
278AS & 250AS (1)SL13 & (1)SL22
278AS & 250AS or
(1)SL3 & (2)SL22
1P
SC
A
2
278AS
SL3
2
SD
A
2-3
4
5
SL4
279AS
SL14
279AS & 293AS (1)SL14 & (1)SL24
279AS & 293AS or
(1)SL4 & (2)SL24
3
SE
A
2
3
4
5
305AS
305AS
326AS
326AS
SL6
SL7
(2)SL6
(1)SL6 & (1)SL7
4
SF
A
2
3
4
5
306AS
306AS
326AS
326AS
SL8
SL9
(2)SL8
(1)SL8 & (1)SL9
5
SG
A
2
3
328AS
328AS
SL10
SL11
A
6
SH
2
3
342AS
342AS
SL25
SL26
B
2
3
370AS
370AS
SL25
SL26
A
2
3
397AS
SL30
SL31
7
SJ
Terminals
Capacitor Switching
Power Terminals
The kilovar ratings of enclosed, three phase contactors
used as switches for capacitor loads, when only one
load appears on the secondary of a distribution system
are shown in the table on Page 13.
NEMA
Type
Size
Type
of Lug
Wire
Sizest
Min.-Max.
Wire
Type
Sizest
of Lug
Min.-Max.
00,
0&1
SA, SB
& SC
Pressure
Wire
#14-#8
Pressure
#16-#12
Wire
2
SD
Box Lug
#14-#4
Pressure
#16-#12
Wire
3
SE
Box Lug
#14-1/0
Pressure
#16-#12
Wire
4
SF
Box Lug
#8-250 kcmil
Pressure
#16-#12
Wire
5
SG
Box Lug
#4-500 kcmil
Pressure
#16-#12
Wire
6
SH
Parallel
Groove
One or two
250-500 kcmil
per phase
Pressure
#16-#12
Wire
7
SJ
Parallel
Groove
One to four
250-500 kcmil
per phase
Pressure
#16-#12
Wire
Coil Burdenq
Inrush VA
Sealed VA
Sealed Watts
NEMA No. of
50
60
50
60
50
60
Size
Poles
Hertz Hertz Hertz Hertz Hertz Hertz
00
0&1
2-3
...
165
...
33
...
6
1-5
232
245
26
27
7.7
7.8
2&3
296
311
36
37
2
12
14
4&5
429
438
37
38
2-3
676
700
47
46
15
14
3
4-5
1260
1185
89
85
23.4
22
4
2-5
...
973
...
81
...
25
5
2-3
2970
2970
250
212
42
39
6a
2-3
1495
1780
56
48
27
32
7a
2-3
...
1960
...
59
...
36
q
Mean values.
a Size 6 and 7 have a DC coil. The values shown are for the AC input
to the DC power supply that provides power to the coil.
Control Terminals
t
Solid or stranded copper wire.
14
© 1998 Square D All Rights Reserved
5/98
Full Voltage Contactors and Starters — NEMA
Application Data – Class 8502, 8536
Control Circuit Transformers
Auxiliary Units
Auxiliary contacts, power poles, and timer
attachments can be added by the factory or in the
field on all Type S starters and contactors. The
table below shows the maximum number of
auxiliary units (in addition to the holding circuit
contact) that can be added to a given size starter
or contactor. In addition, it is possible to add a
second internal contact on NEMA Size 0, 1, and 2
contactors and starters.
No. of
Maximum Number of External
Poles of
NEMA
Auxiliary Units (In addition to
Type
Basic
Size
holding circuit contact)
Contactor
00
SA
SB
0, 1 & 2 SC
SD
SE
3, 4 & 5 SF
SG
6&7
SH
SJ
4 single circuit auxiliary contacts (N.O. or N.C.)
if second internal auxiliary contact is not used.
4 single circuit auxiliary contacts (N.O. or N.C.)
3 single circuit auxiliary contacts (N.O. or N.C.)
plus 1 attached timer (ON or OFF delay).
2 single circuit auxiliary contacts (N.O. or N.C.)
1, 2 or 3
plus 1 power pole adder (1 or 2 poles, N.O. or
N.C.).
1 attached timer (ON or OFF delay) plus 1
power pole adder (1 or 2 poles, N.O. or N.C.)
plus 1 auxiliary contact.
2 single circuit auxiliary contacts (N.O. or N.C.)
4 or 5
1 timer attachment plus 1 auxiliary contact.
4 single circuit auxiliary contacts (N.O. or N.C.)
2-5
2 single circuit (Sizes 3 & 4) or 3 single circuit
(Size 3 & 4) (Size 5) auxiliary contacts plus 1 attached timer
(ON or OFF delay).
2 single circuit auxiliary contacts (N.O. or N.C.)
2-3
plus 1 NEMA Size 0-1 or Size 2 power pole
(Size 5)
adder (1 or 2 poles, N.O. or N.C.)
4 single circuit auxiliary contacts (N.O. or N.C.)
3 single circuit auxiliary contacts (N.O. or N.C.)
plus 1 attached timer (ON or OFF delay).
2-3
2 single circuit auxiliary contacts (N.O. or N.C.)
plus 1 NEMA Size 0-1 or Size 2 power pole
adder (1 or 2 poles, N.O. or N.C.)
Class 9070 Type T machine tool control
transformers are normally used when it is
necessary to provide a lower voltage to the control
circuit. This transformer with fused protection may
be ordered from the factory by specifying Form
F4T. The addition of a transformer often requires
the use of a larger enclosure. The table below
shows the transformer selection for given sized
starters and contactors with or without auxiliary
units.
NEMA
Size
2-3
See Class 9999 for field modification kits.
Form Number of Additional Auxiliary
Contacts
When ordering factory installed auxiliary contacts,
the Form designations listed should be used.
Number of N.O.
Contacts
0
1
2
3
3
4
Number of N.C.
Contacts
Form Number
1
2
3
4
0
1
2
3
0
1
2
0
1
0
X01
X02
X03
X04
X10
X11
X12
X13
X20
X21
X22
X30
X31
X40
Transformer
Class 9070
Type
With max. of 2 auxiliary
contacts
SB
SC
0&1
1-3
With timer and maximum of
1 auxiliary contact
T50
With 3 or 4 auxiliary
contacts with timer and 2 or T100
3 auxiliary contacts
SB
SC
4&5
With or without auxiliary
contacts or timer
0&1
Mechanically SB
Interlocked SC
Devices
1-5
With or without attachments T100
2
SD
2-5
With or without attachments T100
3
SE
2-3
With or without attachments GO3j
3
SE
4&5
With or without attachments T300
4
SF
2-5
With or without attachments T300
5
SG
2-3
Any
T500
6, 7
SH,
SJ
2-3
Any
u
0&1
j
Factory Installed Auxiliary Contacts
Additional auxiliary contacts may be factory or
field added to any Type S contactor or starter. See
table above for maximum number of auxiliary
units. The table below lists the Form designations
for factory installed electrical contacts.
No.
Type of
Auxiliary Units
Poles
u
T100
Class 8502 & 8536 Type S, Size 3 standard NEMA Type 1, 4 and 12
enclosures have space for field mounting a fused control circuit
transformer. A Class 9070 Type GFT3 transformer and fuse block kit
is available for Form F4T requirements in a NEMA Type 1 enclosure.
NEMA Type 4 and 12 enclosures utilize a Class 9070 T150
transformer and a Class 9999 SF4 fuse block.
A Class 9070 transformer is an integral part of the Size 6 and Size 7
control circuit providing 120 volt control circuit voltage as standard.
Power Poles
Single or double circuit power pole adders may be
factory or field installed on 2 and 3 pole Type S
contactors and starters. The table below lists the
Form designation for factory installed power pole
adders. Only one power pole adder may be
installed per contactor.
Type
NEMA Size
Class 9999
Type
Form
Designation
1 N.O.
0, 1
2
SB6
SB11
Y428
Y436
1 N.C.
0, 1
2
SB7
SB12
Y429
Y437
1 N.O., 1 N.C.
0, 1
2
SB8
SB13
Y435
Y440
2 N.O.
0, 1
2
SB9
SB14
Y430
Y438
2 N.C.
0, 1
2
SB10
SB15
Y434
Y439
15
5/98
© 1998 Square D All Rights Reserved
Full Voltage Contactors and Starters — NEMA
Application Data – Class 8502, 8536
Size 6 Type SH and Size 7 Type SJ Contactors
and Starters
Size 6 Type SH and Size 7 Type SJ contactors and
starters have a DC coil operated by a solid state
rectifier circuit mounted on the device and
powered from an ac source. The Size 6 and 7 are
equipped as standard with a fused control circuit
transformer (Form F4T) rated 240/480-120 volts
60 hertz, 220/440-110 volts 50 hertz. The purpose
of this transformer is to provide an isolated 120
volts 60 hertz, 110 volts 50 hertz, supply for the
control circuit. Size 6 and 7 devices may be
ordered for other system voltages by specifying
the voltage and frequency desired.
Size 6 Starter 8536 SH
Operation Rates
Continuous operation rate: 3 operations/minute
maximum. Jogging or Plugging Duty: 15
operations/minute – 3 minutes maximum.
4. Standard controllers are wired for common
control and are not convertible for operation of
the control circuit from a separate source of
supply voltage. Controllers designated Form S
have special wiring designed for separate
control. They are furnished with an isolating
transformer, usually having a 120 volt primary
and 120 volt secondary, that must not be
bypassed. Form S controllers are not
convertible for operation on common control.
The tables below give the replacement
transformers for Type S Sizes 6 and 7 contactors
and starters. To change voltages on these
devices, coils are not changed, instead
transformers with the desired voltage are
changed.
Replacement Control Transformers for Type S
Size 6
Voltage
Class 9070 Type
Field conversion for other system voltages is
accomplished by one of the following methods,
NOT BY THE USUAL PRACTICE OF CHANGING
THE COIL:
Size 7 Starter 8536 SJ
1. If the factory wiring is indicated as being for
480 volts 60 hertz, 440 volts 50 hertz,
conversion to 240 volts 60 hertz, 220 volts 50
hertz, can be accomplished by reconnecting
the control transformer as illustrated on
instruction sheet supplied with the controller.
This is the same method that would be used
on Class 9070 control circuit transformers.
Conversion to any other voltage requires
replacement of the control transformer. For
other system voltages: i.e. 208, 277, 380, 600
volts, a new transformer with single voltage
primary must be selected from table at right.
Control transformer connections are
illustrated on the instruction sheet supplied
with the controller.
2. If the factory wiring is indicated as being for
any voltage other than 480 volts 60 hertz, 440
volts 50 hertz, conversion to any other voltage
requires replacement of the control
transformer. Refer to table at right.
3. The standard transformer supplied may be
used to power a maximum of five Class 9001
Type K illuminated operators powered with
transformer type light modules. When extra
capacity to power control relays or other
inductive loads is required, a second
transformer must be added. Extra capacity
can be purchased as Form F4T with additions
in 100 VA increments.
60 Hertz
50 Hertz
240/480-120
208-120
277-120
...
600-120
120-120
240-120
220/440-110
...
...
380-110
550-110
110-110
220-110
EO3S2A
EO3S2B
EO3S2C
EO3S2D
EO3S2E
EO3S2F
EO3S2G
Replacement Control Transformers for Type S
Size 7
Voltage
Class 9070 Type
60 Hertz
50 Hertz
240/480-120
208-120
277-120
...
600-120
120-120
240-120
220/440-110
...
...
380-110
550-110
110-110
220-110
EO19S2A
EO19S2B
EO19S2C
EO19S2D
EO19S2E
EO19S2F
EO19S2G
Auxiliary Contacts
A N.O. holding circuit contact and a N.C. auxiliary
contact are provided as standard. The holding
circuit contact may or may not be required for
either 3-wire or 2-wire control. Size 6 and 7
devices have an additional N.C. auxiliary contact
which is wired in the coil control circuit. DO NOT
USE THIS N.C. CONTACT FOR ANY OTHER
PURPOSE.
16
© 1998 Square D All Rights Reserved
5/98
Full Voltage Contactors and Starters — NEMA
Approximate Dimensions, Shipping Weights – Class 8502, 8536
Class 8502 Open Type
Class 8536 Open Type
A
A
D
E
G
F
C
F
C
G
B
H
B
H
RESET
I
Figure 1
I
D
E
Figure 2
Class
8502
NEMA
Size
Type
Dimensions – Inches/mm (Refer to Appropriate Figure)
No.
Fig. Mtg.
A
B
C
D
E
F
of
No. Screws
Poles
IN
mm IN
mm IN
mm IN mm IN mm IN
00
SAO
2-3
0
1
SBO
SCO
1-3
4-5
2
SDO
3
G
H
Wt
(Lbs)
I
mm IN
mm
IN
mm
IN
mm
(2) #10
3.22
82
4.34
110
4.22
107
1.63 41
1.63 41
.22
6
3.94
100
...
...
...
...
4
1
(2) #10
3.22
4.25
82
108
4.34
4.34
110
110
4.22
4.22
107
107
1.63 41
1.63 41
1.63 41
2.63 67
.22
.22
6
6
3.94
3.94
100
100
...
...
...
...
...
...
...
...
4
41⁄2
2-3
4-5
1
(3) #10
4.94
5.63
125
143
5.13
5.13
130
130
4.94
4.94
125
125
2.16 55
2.16 55
2.16 55
3.47 88
.22
.22
6
6
4.59
4.59
117
117
.53
.53
13
13
1.06 27
1.06 27
63⁄4
81⁄4
SEO
2-3
4-5
1
(3) 1⁄4"
(3) 5⁄16"
5.47
9.75
139
248
7.09
7.88
180
200
6.50
6.50
165
165
1.88 48
3.59 91
.31
3.94 100 5.81 148 .31
8
8
6.03
7.00
153
178
3.25
4.53
83
115
4.75 121 14
9.06 230 22
4
SFO
2-3
4-5
1
(3) 5⁄16"
(3) 5⁄16"
6.00
9.75
152
248
8.19
8.19
208
208
6.50
6.50
165
165
2.06 52
3.94 100 .31
3.94 100 5.81 148 .31
8
8
7.00
7.00
178
178
3.59
4.53
91
115
5.31 135 18
9.06 230 22
5
SGO
2-3
1
(3) 1⁄2"
8.66
220
12.31 313
8.75
222
3.25 83
5.81 148 .63
16
11.13 283
4.75
121
7.25 184 45
6
SHO
2-3
1
(3) 1⁄2"
12.34 313
28.06 713
9.00
229
3.53 90
5.78 147 5.06 129 18.56 471
4.75
121
7.25 184 80
7
SJO
2-3
1
(3) 1⁄2"
12.34 313
37.25 946
10.88 276
3.53 90
5.78 147 7.22 183 22.38 568
4.75
121
7.25 184 135
00, 0, 1, 1P SAO-SCO 2-3
2
(3) #10
3.50
89
6.77
172
4.22
107
.50
13
1.00 25
1.61 41
.20
5
6.25
159
3.97 101 5
0, 1
SBO-SCO 4
2
(3) #10
4.53
115
6.77
172
4.22
107
.50
13
1.00 25
2.66 68
.20
5
6.25
159
3.97 101 51⁄2
2
SDO
2-3
4
2
(3) #10
4.31
5.63
109
143
7.81
7.81
198
198
4.94
4.94
125
125
.50
.50
13
13
1.00 25
1.00 25
2.16 55
3.47 88
.20
.20
5
5
7.34
7.34
186
186
4.06 103 73⁄4
4.06 103 91⁄4
3
SEO
2-3
4
2
(3) 1⁄4"
(3) 5⁄16"
5.47
9.75
139
248
11.09 282
12.13 308
6.50
6.50
165
165
.88 22
1.81 46
1.75 44
1.75 44
3.59 91
.31
5.81 148 .31
8
8
10.19 259
11.19 284
5.75 146 17
5.75 146 25
4
SFO
3
4
2
(3) 5⁄16"
(3) 5⁄16"
6.00
9.75
152
248
12.88 327
12.88 327
6.50
6.50
165
165
1.81 46
1.81 46
1.75 44
1.75 44
3.94 100 .31
5.91 150 .31
8
8
11.19 284
11.19 284
5.75 146 22
5.75 146 25
5
SGO
3
2
(3) 1⁄2"
8.56
217
17.56 446
8.75
222
4.75 121 7.25 184 5.38 137 .63
16
16.38 416
6.00 152 62
6
SHO
3
2
(3) 1⁄2"
12.34 313
28.06 713
9.00
229
4.75 121 7.25 184 5.78 147 5.06
129
18.56 471
8.69 221 85
7
SJO
3
2
(3) 1⁄2"
12.34 313
37.25 946
10.88 276
4.75 121 7.25 184 5.78 147 7.22
183
22.38 568
9.00 229 140
8536
1
17
5/98
© 1998 Square D All Rights Reserved
Full Voltage Contactors and Starters — NEMA
Approximate Dimensions, Shipping Weights – Class 8502, 8536
NEMA Type 1 — General Purpose Enclosure
B
E
H
(3) Closing Plates
A
D
K
L
C
Pilot
Light
K
(4) I Dia.
Mounting Holes
A
J
H
E
G
A
F
B
B
G
F
RESET
RESET
H
G
H
I
H
E
Figure 3
D
F
C
C
Figure 4
Figure 5
NEMA
Size
Class
Type
No.
of
Poles
Fig. Mtg.
No. Screws
Dimensions – Inches/mm (Refer to Appropriate Figure)
C
A
B
D
E
F
G
H
8502 8536
00
0
1
8502 & 8536
SAG
SBG
SCG
All
3
(3) #10
6.00
152
10.00
254
5.28
134
5.56
141
3.00
76
.88
22
8.13
207
1.00
25
2
8502 & 8536
SDG
All
3
(4) 1⁄4"
3
(4)
7⁄16"
12.69
322
21.81
554
25.16
639
44.22
1123
20.22
514
34.50
876
6.03
153
8.00
203
9.00
229
12.81
325
13.13
334
23.50
597
6.31
160
8.38
213
9.00
229
12.94
329
13.13
334
23.50
597
...
3⁄8"
7.81
198
11.44
291
11.25
286
17.22
437
65.75
1670
93.00
2362
1.09
28
1.53
39
1.25
32
2.13
54
11.00
279
10.50
267
18.75
476
1.25
32
2.13
54
64.50
1638
1.09
28
1.53
39
22.31
567
40.00
1016
2.31
59
3
8502 & 8536
SEG
All
4
8502 & 8536
SFG
All
4
(4)
5
8502 & 8536
SGG
All
4
(4) 9⁄16"
6
8502 & 8536
SHG
All
5
(4) 11⁄16"
7
8502 & 8536
SJG
All
5
...
...
8.59
218
13.00
330
...
Wt (Lbs)
Class Class
8502
8536
I
J
K
L
.94
24
4.13
105
5.00
127
...
...
71⁄2
8
1.09
28
1.53
39
1.44
37
2.13
54
5.50
140
5.63
143
8.38
213
.44
11
.56
14
5.75
146
7.75
197
1.09
28
1.53
39
5.63
143
8.38
213
141⁄2
151⁄2
34
37
...
...
...
52
56
...
...
...
143
160
...
...
...
...
226
231
...
...
Floor Mounting
NEMA Type 1 — General Purpose Enclosure with Form F4T
(4) H Dia.
G
Mounting Holes
(4) I Dia.
Mounting Holes
A
H
F
B
B
G
RESET
H
E
D
A
C
E
Figure 3
NEMA
Class
Size
0
1
F
Dimensions – Inches/mm (Refer to Appropriate Figure)
No.
C
Fig. Mtg.
Type of
A
B
D
E
No. Screws
8502
8536
Poles
IN
mm IN
mm IN
mm IN
mm IN
mm IN
8502 & 8536 SBG
8502 & 8536 SCG
All
All
6
6
(4) 9⁄32
(4) 9⁄32
6.34
161
15.88 403
5.00
127
5.19
132
2
8502 & 8536 SDG
All
7
(4) 5⁄16
14.88 378
3
8502 & 8536 SEG
2–3
3
(4) 3⁄8
Same as Standard NEMA 1 Dimensions, see above.
4
8502 & 8536 SFG
2–3
7
(4) 3⁄8
18.16 461
5
6
7
D
8502 & 8536 SGG
8502 & 8536 SHG
8502 & 8536 SJG
C
Figure 3
All
All
All
7
5
5
9⁄16
(4)
(4) 11⁄16
...
14.13 359
29.16 741
7.56
9.25
192
235
7.66
9.25
195
235
4.66
F
mm IN
21
G
mm IN
118
.84
14.38 365
12.75 324
1.0
6
27
1.06
27
15.50 394
1.3
3
34
1.33
34
H
I
mm IN
mm IN mm
19
7
... ...
12.00 305
1.0
6
27
.3
1
8
26.50 673
1.3
3
34
.4
4
11
.75
.28
Same as Standard NEMA 1 Dimensions, see above.
Form F4T is supplied as standard. Refer to Page 16.
18
© 1998 Square D All Rights Reserved
5/98
Full Voltage Contactors and Starters — NEMA
Approximate Dimensions, Shipping Weights – Class 8502, 8536
A
E
D
NEMA Type 4 & 4X — Stainless Steel Watertight Enclosuresq
G
D
B
I
J
K
8502
SBW
SCW
All
6.38
162
7.13
181
13.19
335
1.56 3.25
40 83
12.00 .59
305 15
1.19
30
11.78
299
1.63
41
...
SBW
SCW
All
6.38
162
7.81
198
13.19
335
1.56 3.25
40 83
12.00 .59
305 15
1.88
48
11.78
299
1.63
41
1"
Dia.
Hub
17
8536
2.31 .31
59 8 3⁄4"
Dia.
2.31 .31 Hub
59 8
...
18
8.13
207
7.88
200
16.19
411
1.56 5.00
40 127
15.00 1.09 1.94
381 28 49
14.75
375
2.00
51
...
8.56
217
16.19
411
1.56 5.00
40 127
15.00 1.09 2.88
381 28 73
14.75
375
2.00
51
11⁄2"
Dia.
Hub
24
8.13
207
2.63 .31
67 8 3⁄4"
Dia.
2.63 .31 Hub
67 8
...
25
21⁄2"
65
...
Dia.
Hub
69
...
...
68
F C
G
(4) L Dia.
Mounting Holes
I
0
&
1
8502
2
W X
All
SEW
H
8502
K
Figure 8
NEMA Type 4 & 4X
Watertight Enclosure
A
E
SEW
8536
All
SFW
18.16 8.75
461 222
18.16 9.56
461 243
32.22
818
32.22
818
3.08 12.00 30.50 .88
78 305 775 22
3.08 12.00 30.50 .88
78 305 775 22
3.69
94
4.50
114
26.72
679
26.72
679
2.56
65
2.56
65
W.
Bot.
L Only
3⁄4"
3.19 .44
Dia.
81 11
Hub
3⁄4"
21⁄2"
Dia.
Hub
...
73
3⁄4"
159
176
227
232
...
...
W
Bot.
Only
X Top
&
Bot.
3.19 .44
Dia.
81 11
Hub
5
8502 & 8536 SGW
All
17.22 12.63 47.22
437 321 1199
4.13 9.00
105 229
46.00 .63
1168 16
4.59
117
28.31
719
3.13
80
5.75 .56
Dia.
146 14
Hub
31⁄2"
Dia.
Hub
6q
8502 & 8536 SHW
All
20.22 12.13 65.22
514 308 1657
4.13 12.00 64.00 .63
105 305 1626 16
4.59
117
30.81
783
2.69
68
3⁄4"
4.50 .56
Dia.
114 14
Hub
(2) 3"
Dia.
Hub
7q
8502 & 8536 SJW
All
34.50 23.50 101.00
Floor Mounting
876 597 2565
Size 6 and 7 are sheet steel enclosures and are rated NEMA Type 4 only.
NEMA Type 4 & 4X — Stainless Steel Watertight Enclosures with Form F4Tq
G
D
All
SFW
3
&
4
q
D
SDW
8536
J
Weight (Lbs)
X Top
& Bot. Class Class
8502 8536
Dimensions – Inches/mm (Figure 8)
No.
Type of
B
C
D E
F
G H
Poles A
NEMA
Class
Size
B
NEMA
Class
Size
F C
G
(4) L Dia.
Mounting Holes
0
&
1
No.
Type of
Poles
Dimensions – Inches/mm (Figure 9)
SBW
All
All
8502
SCW
SBW
8536
SCW
I
8502
W X
2
J
SDW
A
B
C
D
E
F
12.63 7.13
321
181
4.69
119
2.56
65
7.50
191
12.63 7.81
321
198
14.69
373
2.56
65
14.88 7.56
378
192
16.31
414
14.88 8.25
378
210
16.31
414
G
H
I
J
K
L
13.50 .59
343
15
3.19
81
18.41
468
1.66
42
2.31
59
.31
8
3⁄4
1
7.50
191
13.50 .59
343
15
3.88
99
18.41
468
1.66
42
2.31
59
.31
8
3⁄4
1
2.56
65
9.75
248
15.00 .66
381
17
3.19
81
20.88
530
2.00
51
2.63
67
.31
8
3⁄4
11⁄2
2.56
65
9.75
248
15.00 .66
381
17
3.88
99
20.88
530
2.00
51
2.63
67
.31
8
3⁄4
11⁄2
All
8536
H
SEW
K
Figure 9
NEMA Type 4 & 4X
Watertight Enclosure
3
&
4
8502
2-3
Same as Standard NEMA Type 4 dimensions, see above.
2-3
See as Standard NEMA Type 4 dimensions, see above.
SFW
SEW
8536
SFW
5
8502 & 8536 SGW All
6q
8502 & 8536 SHW
All
7q
8502 & 8536 SJW
All
Same as Standard NEMA Type 4 dimensions, see above.
Form F4T is supplied as standard. Refer to Page 16.
q
Size 6 and 7 are sheet steel enclosures and are rated NEMA Type 4 only.
19
5/98
© 1998 Square D All Rights Reserved
Full Voltage Contactors and Starters — NEMA
Approximate Dimensions, Shipping Weights – Class 8502, 8536
A
E
D
D
B
G
Size 2 Only
A
E
F
C
(2) L Dia.
Mounting Holes
(Size 1)
Size 2
Only
(4) L Dia.
Mounting Holes
(Size 2)
C
F
RESET
G
1.00
Conduit Hub
Top and Bottom
Size 1
Conduit Hub
38 Top and Bottom
Size 2
.75 Conduit Hub in
19 Bottom Size 1 and Size 2
25
1.50
I
B
J
H
K
Figure 10A
Figure 10B
NEMA Type 4X — Watertight and Corrosion Resistant Glass Polyester Enclosures
Dimensions — Inches/mm (Figure 11)
No.
NEMA
Class Type of
Fig.
Size
Poles
A
B
C
D
E
IN mm IN mm IN mm IN mm IN
0, 1
2
8502 & SBW
All
SCW
8536
8502 &
SDW All
8536
F
mm IN
G
mm IN
H
mm IN
I
mm IN
J
mm IN
K
mm IN
L
mm IN mm
Bot. Top &
Hub Bot.
Only Hub Wt
(Lbs)
W
X
10A 6.50 165 6.44 164 12.13 308 .75 19
5.00 127 8.75 222 1.69 43
3.34 85
10.06 256 1.31 33
2.13 54
.31 8
3⁄4
1
17
10B 8.50 216 7.06 179 13.88 353 .75 19
7.00 179 10.50 267 1.69 43
3.91 99
11.94 303 1.63 41
2.38 60
.31 8
3⁄4
11⁄2
22
10.13 257 21.50 546 . . .
...
...
...
...
...
...
...
...
...
... ...
...
...
...
18.50 470 32.25 819 . . .
...
...
...
...
...
...
...
...
...
... ...
...
...
...
SBW
8502 &
0-2t
SCW All
10B 16.88 429 9.78 248 22.75 578 . . . . . .
8536
SDW
8502 & SEW
3-4j
All
10B 25.81 656 11.94 303 33.50 851 . . . . . .
SFW
8536
t
With control power transformer (Form F4T).
j
Dimensions also for Form F4T.
A
E
G
F
B
D C
L
H
X
W
K
I
J
Figure 11
NEMA Type 9 Enclosures for Hazardous Locations — Sheet Steel
Dimensions — Inches/mm (Figure 11)
No. of
NEMA
A
B
C
D
E
Type
Poles
Size
IN
mm IN mm IN
mm IN
mm IN
F
mm IN
G
H
mm IN mm IN
I
mm IN
J
mm IN
K
mm IN
mm
0
1
SBE
SCE
2-4
8.84
225
8.22 209
13.00 330
12.00 305
6.00
152
1.38 35
.50 13
14.69 373
3.91 99
2.13 54
2.00 51
2
SDE
2-4
10.34 263
8.97 228
16.13 410
15.00 381
7.50
191
1.38 35
.56 14
16.94 430
3.91 99
2.75 70
2.38 60
3
SEE
2-4
12.84 326
9.72 247
24.16 614
22.25 565
9.00
229
1.88 48
.97 25
20.56 522
4.41 112
3.25 83
2.88 73
4
SFE
2-4
15.84 402
9.72 247
34.16 868
32.25 819
12.00 305
1.88 48
.97 25
23.56 598
4.41 112
3.25 83
2.88 73
X Bot.
Only
W Top
& Bot.
3⁄4"
1"
241⁄2
Dia. Hub Dia. Hub
3⁄4"
Dia. Hub
3⁄4"
Dia. Hub
3⁄4"
Dia. Hub
11⁄2"
311⁄4
Dia. Hub
2"
54
Dia. Hub
21⁄2"
74
Dia. Hub
NOTE: Devices with Form F4T may use larger enclosure. Consult local Square D Field Office for dimensions.
20
© 1998 Square D All Rights Reserved
Wt
(Lbs)
5/98
Full Voltage Contactors and Starters — NEMA
Approximate Dimensions, Shipping Weights – Class 8502, 8536
NEMA Type 7 & 9 Enclosures for Hazardous Locations
Sizes 0-2, Bolted Cover, Cast Iron, Sizes 0-5, Bolted Cover, Cast Aluminum, Sizes 0-5, SPIN TOP®, Cast Aluminum
Top View
Rear View
Space Required
To Remove
Top Cover
12.00
11.00
(1) 1-11 1/2 Pipe Tap
at Top Std.
279
.63
9.75
248
9.25
16
235
2.40
4.90
61
260
2.40
.25
178
16
125
10.75
273
10.25
16
7.00
.63
.25
191
16
149
E
Q
7.50
.63
5.88
61
6
N
(1) 1-11 1/2 Pipe Tap
at Top Std.
305
.63
6
(2) "L" Pipe
Tap Top and
Bottom
Optional
Mounting
Optional
Mounting
7.90
12.70
13.25
337
9.63
14.44
201
323
12.00
210
Figure 12 Size 0 and 1
235
A
C
B
D
F
H S
K
L
M
J
T
Mtg. Holes
and/or Slots (3)
Circuit Breaker
Operational Handle –
Combination Form Only
P
(Add 1.00 Inch To
Overall Width)
Overload
Reset
(4) .42 Dia. Mounting Holes
10
(1) 1 1/2 - 11 1/2 Pipe Tap
at Bottom Std.
9.25
(1) 3/4 - 14 Pipe Tap
at Bottom Std.
G
Threaded
Cover
Enclosure
349
(4) .42 Dia. Mounting Holes
10
(1) 1 - 11 1/2 Pipe Tap
at Bottom Std.
8.25
381
13.75
305
(1) 3/4 - 14 Pipe Tap
at Bottom Std.
15.00
245
367
Rear Seal
R
Space Required To
Remove Bottom Cover
Figure 13 Size 2
Figure 14 Size 0-5
NEMA 7 & 9 Bolted Cover, Cast Iron
NEMA
Size
0, 1
2
Type
SBT
SCT
SDT
Dimensions — Inches/mm
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Wt
(Lbs)
R
See Figure 12
59
See Figure 13
75
NEMA 7 & 9 SPIN TOP ® Enclosure – Figure 14
Dimensions — Inches/mm
NEMA
Type
Size
A
Bt
Bj
Ct
Cj
D
Et
Ej
F
G
Ht
Hj
J
K
L
M
N
P
R
SBR
SCR
10.63
270
25.06
637
30.06
764
34.69
881
47.69
1211
14.69
373
6.25
159
11.25
286
7.69
195
11.13
283
2.00
51
9.00
229
7.63
194
7.38
187
2.06
52
9.38
238
5.25
133
1.25
32
.38
10
2
SDR
12.00
305
29.31
744
34.31
871
42.81
1087
54.81
1392
16.75
425
6.75
171
11.75
298
7.69
195
14.75
375
3.00
76
9.00
229
11.50
292
8.50
216
2.06
52
9.38
238
5.25
133
1.50
38
.38
10
3-4
SER
SFR
16.13
410
20.75
527
37.50
953
62.13
1578
40.50
1029
62.13
1578
60.00
1524
103.63
2632
66.50
1689
103.63
2632
20.25
514
25.75
654
8.63
219
24.13
613
11.63
295
24.13
613
8.63
219
13.88
353
20.25
514
24.13
613
4.50
114
20.00
508
8.00
203
20.00
508
18.00
457
21.50
546
12.00
305
14.38
365
2.63
67
4.75
121
11.00
279
17.00
432
5.50
140
8.00
203
2.50
64
4.00
102
.50
13
.63
16
0-1
5
t
j
SGR
Wt
(Lbs)
70
100
165
195
375
Without control transformer.
With control transformer (Form F4T)
NEMA 7 & 9 Bolted Cover, Cast Aluminum
V U
O
Circuit Breaker Handle not supplied
on Class 8502 or 8536
H
1/2" NPT for Breather and Drain
L
K
N
R
S T
G
J
P
Mounting for 4 Bolts
Figure 15
Dimensions — Inches/mm
NEMA
H
Type G
Size
IN
mm
IN
mm
0-1
2
3-4
5
SBT
SCT
SDT
SET
SFT
SGT
J
IN
Wt
(Lbs)
mm
K
IN
mm
L
IN
mm
N
IN
mm
P
IN
mm
Q, R
IN
mm
S, T, U, V
IN
mm
14.25
362
17.25
438
9.50
241
12.25
311
8.88
226
4.50
114
11.00
279
2.38
60
3.13
80
75
13.63
346
27.63
702
9.50
241
12.25
311
19.25
489
9.63
245
11.00
279
2.38
60
3.13
80
115
18.13
461
13.63
346
10.00
254
16.25
413
19.25
489
9.63
245
12.63
321
2.38
60
3.75
95
180
24.50
622
45.63
1159
13.75
349
22.50
572
27.50
699
13.75
349
15.38
391
3.44
87
4.00
102
500
21
5/98
© 1998 Square D All Rights Reserved
Full Voltage Contactors and Starters — NEMA
Approximate Dimensions, Shipping Weights – Class 8502, 8536
D
A
E
D
NEMA Type 12 — Dusttight Enclosure
G
F C
NEMA
Class
Size
Type
0
SBA
Dimensions – Inches/mm (Figure 16)
No.
of
B
C
D
E
F
Poles A
8502 & 8536
1
SCA
I
2
8502 & 8536 SDA
3
H
Figure 16
NEMA Type 12
Industrial Use
Enclosure
D
A
E
D
G
F C
I
I
J
Class Class
8502 8536
8.53
217
12.75
324
1.56
40
3.25
83
12.00
305
.38
10
3.56
90
12.25
311
.31
8
15
16
All
8.13
207
9.28
236
16.00
406
1.56
40
5.00
127
15.00
381
.50
13
3.56
90
15.38
391
.31
8
22
23
18.16
461
9.56
243
31.50
800
3.08
78
12.00
305
30.50
775
.50
13
4.50
114
26.72
679
.44
11
65
68
All
4
SFA
5
8502 & 8536 SGA
All
17.22
437
13.44
341
47.00
1194
4.13
105
9.00
229
46.00
1168
.50
13
5.41
137
28.31
719
6
8502 & 8536 SHA
All
20.22
514
13.00
330
65.00
1651
4.13
105
12.00
305
64.00
1626
.50
13
6.44
164
30.88
784
7
8502 & 8536 SJA
All
34.50
876
23.50
597
93.00
2362
Floor Mounting
69
73
.56
14
160
177
.69
18
228
233
...
...
NEMA Type 12 — Dusttight Enclosure with Form F4T
NEMA
Class
Size
Dimensions – Inches/mm (Figure 17)
No.
A
B
C
D
E
Type of
Poles
IN
mm IN mm IN
mm IN mm IN
0
SBA
8502 & 8536
B
G
(4) J Dia.
Mounting Holes
H
6.38
162
SEA
8502 & 8536
G
All
B
G
(4) J Dia.
Mounting Holes
Weight (Lbs)
1
SCA
2
8502 & 8536 SDA
3
SEA
8502 & 8536
4
F
mm IN
G
H
I
mm IN mm IN
J
mm IN
mm IN mm
All
11.88 302 8.00 203 13.50 343 2.81 71
6.75 171 12.75 324 .38 10
3.91 99
18.38 467 .31 8
All
14.88 378 8.13 207 16.00 406 2.56 65
9.75 248 15.00 381 .38 10
3.66 93
21.50 546 .31 8
2–3
SFA
Same as Standard NEMA Type 12 dimensions, see above.
5
8502 & 8536 SGA All
6
8502 & 8536 SHA All
7
8502 & 8536 SJA
H
Figure 17
NEMA Type 12
Industrial Use
Enclosure
D
A
E
D
G
F C
Form F4T is supplied as standard. Refer to Page 16.
NEMA Type 3R — Rainproof and Sleet Resistant Enclosures
Dimensions — Inches/mm (Figure 17)
No.
NEMA
Class Type of
Size
B
C D1 D2 E
F
G1 G2 H1 H2 J
Poles A
0&1
B
G
(4) J Dia.
Mounting Holes
I
2
3
H
Figure 18
NEMA Type 3R
Outdoor Use
Enclosure
All
4
8502 & SBH,
All
8536
SCH
8502 &
SDH
8536
All
8502 &
SEH
8536
All
8502 &
SFH
8536
All
8.84
225
12.28 7.13 1.38 1.44 6.00
312
181 35 37 152
7.50
191
K
L
2.59 2.19 2.06 2.63 14.28 1.38 1.38
66 56 52 67 363
35 35
M
N
P
K.O. K.O.
X
Y
1⁄2
1.88 4.38 1.84 3
⁄4
48 111 47
1
11.50 2.59 2.19 2.06 2.63 16.78 1.31 1.75
292
66 56 52 67 426
33 44
1
2.13 4.88 1.84 1
1 ⁄4
54 124 47
11⁄2
12.84 25.28 8.63 1.38 1.44 10.00 20.50 2.59 2.19 2.06 2.63 19.78 1.31 1.94
326
642
219 35 37 254
521
66 56 52 67 502
33 49
1
2.44 6.38 1.84 11⁄4
62 162 47 2
21⁄2
9.84
250
16.28 8.63 1.38 1.44 7.00
414
219 35 37 178
12.84 40.28 9.13 1.38 1.44 10.00 35.50 2.59 2.19 2.06 2.63 20.28 1.31 2.31
326
1023 232 35 37 254
902
66 56 52 67 515
33 59
1
2.69 6.38 1.84 11⁄4
68 162 47 2
21⁄2
22
© 1998 Square D All Rights Reserved
5/98
1⁄2
3⁄4
1
1⁄2
3⁄4
1⁄2
3⁄4
1⁄2
3⁄4
Full Voltage Contactors — NEMA
Application Data
Altitude
Electrical Ratings
Characteristic
Size 4
Size 5
Size 6
40
50
75
100
100
75
100
150
200
200
150
200
300
400
400
80
160
200
160
320
400
Maximum Motor HP at:
200 V
230 V
380 V
460 V
575 V
The vacuum contactor is designed to tolerate
normal barometric pressure variances up to 6600
feet above sea level. If the contactor is to be used
above 6600 feet above sea level, please consult
the factory.
3 Phase Capacitor Switching – KVAR
230 V
460 V
575 V
40
80
100
Transformer Switching – KVA 3 Phase, 3-Pole
Class 8502 Type WF
Vacuum Contactor
240 V
480 V
600 V
23
47
59
47
94
117
94
188
234
Coil Data
Inrush VA
Sealed VA
Sealed Watts
Pick-up Volts
Drop-out Volts
Pick-up Time (ms)
Drop-out Time (ms)
300
600
30
20
6
20
70% of rated coil voltage
50% of rated coil voltage
18-22
24-32
90-120
96-100
1450
32
30
24-32
96-100
Additional Electrical Characteristics
Number of Poles
Max. Voltage Rating
Enclosed Ampere Rating
Max. Closing Current
Max. Interrupting Current
Short Time Current (RMS):
1 second
2 seconds
Dielectric Strength, volts
Max. Allowable Interrupting
Impulse Voltage, VA (1 x 40ms)
3
600
135
1600
1600
3
600
270
3000
3000
3
600
540
6000
6000
2400
1600
5375
1200/hr
15000
4500
3000
5375
1200/hr
15000
9000
6000
5375
1200/hr
15000
General Information
Class 8502 Type W non-reversing vacuum
contactors are a new addition to the Square D line
of contactors. These contactors are used to switch
capacitors, transformers and electric motors
where overload protection is separately provided.
Type W vacuum contactors are designed for
operation at 600 Volts, 50/60 Hertz.
File E78351
CCN NLDX2
LR75167, 75168
Class 3211-04
By design, these contactors are well suited to
heavy-duty applications in harsh environments.
The power contacts are sealed in ceramic tubes,
called vacuum interrupters or vacuum bottles,
where the air has been evacuated. Arc quenchers
are not required because any arc formed between
opening contacts is not sustained due to the
presence of the vacuum. The arc is extinguished
when the current crosses zero after the contacts
are opened, therefore the arc typically does not
survive more than one half cycle. There is one
vacuum interrupter or bottle per pole, therefore a
three pole contactor has three vacuum
interrupters or bottles. The power contacts are not
affected by ambient conditions or contamination.
This provides for long life and reliable operation in
harsh applications.
Termination Means
The Size 4 vacuum contactor is supplied with line
and load side lugst. The Size 5 and 6 vacuum
contactors are supplied without line and load side
lugs. Class 9999 Type LUW5 and LUW6 lug kits
are available for the Size 5 and 6 contactors.
These kits include six lugs and the necessary
mounting hardware.
Auxiliary Contacts
An auxiliary contact block, Class 9999 Type
WX11, with one normally-open contact and
normally-closed contact is used with the Size 4, 5
and 6 vacuum contactors.
Auxiliary Contact Units
Auxiliary contact units may be added in the field.
the table below shows the maximum number of
units that may be added to a given size contactor
(in addition to the coil auxiliary contact).
Class 8502
Size 4
Size 5
Size 6
3
4
4
Terminals
Size
Power Terminals
Wire Sizeq
Min. – Max.
Control Terminals
Wire Sizeq
Min. – Max.
4
#12-4/0
#16-12
5c
One #0-500 kcmil per phase
#16-12
6c
Two #0-500 kcmil per phase
#16-12
c
q
Power terminal lugs are not supplied on Size 5 and 6 contactors.
Values in table reflect those for the Size 5 and 6 lug kits, Class 9999
Type LUW5 and LUW6 respectively.
Solid or stranded copper wire.
23
5/98
© 1998 Square D All Rights Reserved
Full Voltage Contactors — NEMA
Selection – Class 8502
Class 8502 – Full Voltage Vacuum Contactors
NEMA
Size
Enclosed
Ampere
Rating
NEMA Type 1
General Purpose
Enclosure
NEMA Type 4 & 4X
Watertight, Dusttight
Brushed Stainless
Steel Enclosure
(Size 4 & 5 only)
NEMA Type 12
Dusttight & Driptight
Industrial Use
Enclosure
Locked
Rotor
Current
(Amps)
Motor
Volts
Max.
HP
t
Coil
Voltage
Type
Type
Type
Type
40
50
75
100
100
120
240
120
480
600
WFO3V02S
WFO3V03
WFO3V02S
WFO3V06
WFO3V07
WFG3V02S
WFG3V03
WFG3V002S
WFG3V06
WFG3V07
WFW3V02S
WFW3V03
WFW3V02S
WFW3V06
WFW3V07
WFA3V02S
WFA3V03
WFA3V02S
WFA3V06
WFA3V07
Open Type
4
135
1080
200
230
380
460
575
5
270
2160
200
230
380
460
575
75
100
150
200
200
120
240
120
480
600
WGO3V02S
WGO3V03
WGO3V02S
WGO3V06
WGO3V07
WGG3V02S
WGG3V03
WGG3V002S
WGG3V06
WGG3V07
WGW3V02S
WGW3V03
WGW3V02S
WGW3V06
WGW3V07
WGA3V02S
WGA3V03
WGA3V02S
WGA3V06
WGA3V07
6
540
4320
200
230
380
460
575
150
200
300
400
400
120
240
120
480
600
WHO3V02S
WHO3V03
WHO3V02S
WHO3V06
WHO3V07
WHG3V02S
WHG3V03
WHG3V002S
WHG3V06
WHG3V07
WHW3V02S
WHW3V03
WHW3V02S
WHW3V06
WHW3V07
WHA3V02S
WHA3V03
WHA3V02S
WHA3V06
WHA3V07
t
Consult factory for availability of enclosed devices.
6.13
.38
10
156
1.88
.94
Front View
Shown Without
Overtravel
Gauge
48
24
5.22
3.60
Recess for
Auxiliary
Contact
133
Line Term.
91
12.50
318
7.28
6.63
152
.28 Dia.
7
(3) Mtg. Holes
168
1.44 1.44
.94
1.88
Overtravel
Gauge
6.00
37
24
48
129
Load Term.
149
118
64
1.45
37
5.93
Side View
227
2.50 2.50
5.09
5.87
37
4.63
Rear View
Drilling Plan
8.94
185
7.90
201
151
Front View
Side View
Class 8502 Type WF
64
Front View
Class 8502 Type WG
1
2
7.00
178
5.00
Two Dual Circuit Interlocks.
Located on both sides of
contactor when used.
2.67 2.67
68
127
Coil
Interlock
Coil Terminals located on both
sides of contactor.
68
.33 x .75
8
19
Key Holes
8.75
12.90
1
328
Term.
Holes
222
8.00
2
203
13.99
355
.33 Slot
8 (2 Places)
.38
10
6.75
171
Rear View
Drilling Plan
.58
15
3.72
1.28
33
94
Side View
2.67 2.67
68
68
7.90
201
Front View
Class 8502 Type WH
24
© 1998 Square D All Rights Reserved
5/98
Contents
SECTION 2 – REVERSING MAGNETIC STARTERS AND
CONTACTORS
Application Data – Class 8702, 8736 . . . . . . . . . . . . . . . . . . . . . . . . . . 27-28
Selection – Class 8702 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29-30
Selection – Class 8736 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31-32
Application Data – Class 8702, 8736 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Approximate Dimensions – Class 8702, 8736 . . . . . . . . . . . . . . . . . . . 34-36
Application Data, Selection – Class 8702 Vacuum Contactor . . . . . . . . . . 37
Selection – Class 8702 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
25
5/98
© 1998 Square D All Rights Reserved
26
© 1998 Square D All Rights Reserved
5/98
Full Voltage Reversing Contactors and Starters — NEMA
Application Data – Class 8702, 8736
Size 00, 0, 1
Reversing Contactor
AC MAGNETIC REVERSING
CONTACTORS CLASS 8702
ambient insensitive and features phase loss,
phase unbalance and over-current protection.
General Information
MOTOR LOGIC™ Solid State Overload Relay
(SSOLR)
Class 8702 Type S reversing magnetic contactors
are used for starting, stopping, and reversing AC
motors where overload protection is separately
provided. Class 8702 reversing contactors are
available in NEMA Sizes 00-7. Class 8702
reversing contactors consist of two Class 8502
contactors mechanically and electrically
interlocked. Open type devices, Sizes 0-5 are
available in either horizontal or vertical
arrangements. Sizes 00, 6, and 7 are available as
horizontal only. Enclosed devices, Size 00-7 use
horizontally arranged components. Type S
reversing contactors are designed for operation at
600 Volts AC, 50-60 Hertz.
AC MAGNETIC REVERSING STARTERS
CLASS 8736
General Information
Size 00, 0, 1
Reversing Starter
Solid state overload relays are available for Sizes
00-7 starters. These ambient insensitive overload
relays provide phase loss protection, phase
unbalance protection and LED power indicator.
For additional information see the Class 9065
catalog section. To order Type S starters with solid
state overload relays, see Factory Modification
(FORMS).
Bimetallic overload relays are also available for
Sizes 0-6. Ambient Compensated and Noncompensated versions are supplied with manual
and automatic reset, trip current adjustment, and
an alarm contact on Sizes 0-2. For additional
information, see the Class 9065 catalog section.
To order Type S starters with bimetallic overload
relays, see Factory Modifications (FORMS).
Enclosures
Class 8736 Type S reversing magnetic starters
are used for full voltage starting, stopping, and
reversing AC squirrel cage motors. Class 8736
reversing starters are available in NEMA Sizes
00-7. Class 8736 reversing starters consist of one
Class 8502 contactor and one Class 8536 starter
mechanically and electrically interlocked. Open
type devices, Sizes 0-5 are available in either
horizontal or vertical arrangements. Sizes 00, 6,
and 7 are available as horizontal only. Enclosed
devices use horizontally arranged components.
Motor overload protection is provided by melting
alloy type thermal overload relays. Type S starters
are designed for operation at 600 Volts AC, 50-60
Hertz.
Overload Relays
Class 8736 Type S Size 00-6 reversing starters
are provided with melting alloy thermal overload
relay as standard. Interchangeable thermal units
are available in standard trip Sizes 00-6, quick trip
Sizes 00-4, and slow trip Sizes 00-3. Single phase
starters use one thermal unit, three phase
starters use three thermal units.
Class 8702 and 8736 reversing magnetic
contactors and starters are available in the
following enclosures:
• NEMA Type 1 General Purpose Enclosure
• NEMA Type 4 & 4X Watertight and Dusttight
• NEMA Type 7 & 9 Bolted and Spin-Top for
Hazardous Locations
• NEMA Type 12 Dusttight and Driptight for
Industrial Use
The NEMA Type 4 and 4X stainless steel
enclosure (Sizes 0-5) has a brushed finish. For an
electropolished finish, specify Form G16 and add
15% to the price of the standard device. Sizes 6
and 7 are painted sheet steel and are rated NEMA
Type 4 only.
Also, NEMA Type 12 devices are available UL
Listed for use in Class II, Division 2, Group G and
Class III, Divisions 1 and 2 locations. Request
Form G21, no additional charge.
Separate enclosures are available, see
Class 9991.
Class 8736 Size 7 starters are provided with solid
state overload Motor Logic, which has selectable
trip Class 10/20, Ground Fault Detection, and
Communication capabilities for future
enhancements. The solid state overload relay is
27
5/98
© 1998 Square D All Rights Reserved
Full Voltage Reversing Contactors and Starters — NEMA
Application Data – Class 8702, 8736
Holding Circuit Contact
Mechanical Interlocks
Two normally open holding circuit contacts are
provided on all reversing contactors and starters
as standard. Sizes 00-2 contactors use a Class
9999 SX11 auxiliary contact as the holding circuit
contact. Sizes 3-7 contactors use a Class 9999
SX6 auxiliary contact as the holding circuit
contact. Additionally, two normally closed
auxiliary contacts are provided as standard and
wired to prevent energization of both coils at the
same time. Sizes 00-2 use a Class 9999 SX12
auxiliary contact while Sizes 3-7 use a Class 9999
SX7 auxiliary contact for this purpose. See Class
9999, for the holding circuit contact electrical
ratings.
Mechanical interlocks are available for
replacement or field assembly of Type S reversing
contactors and starters (Sizes 00-4 ONLY). See
Class 9999 for additional information.
Auxiliary Contacts
Additional auxiliary contacts may be added to
Type S reversing contactors and starters. See
Page 33 for maximum number of auxiliary units
and Form designations for factory installed
auxiliary contacts. See Class 9999 for auxiliary
contact kits for field installation.
Type S Accessories
Coil Voltages
AC coils are available for application on 50-60
Hertz. NEMA Sizes 00-5 are supplied with coils
that are designed to operate satisfactorily on line
voltages of 85%-110% of rated voltage. NEMA
Size 6 and 7 contactors are supplied with a DC
coil operated by a solid state rectifier circuit that is
powered by an AC source.
Additional accessories such as power poles,
pneumatic timer attachments, and cover mounted
control stations are available as factory or field
modifications.
Please note that Voltage Codes have been
added to the Type designations in order to
improve customer service. It is necessary to
include the Voltage Code when ordering
contactors and starters. Also, 120 Volt Polyphase
reversing contactors and starters will be wired for
separate control.
File E78351
CCN NLDX
File LR60905
Class 3211-04
28
© 1998 Square D All Rights Reserved
5/98
Full Voltage Reversing Contactors — NEMA
Selection – Class 8702
3-Pole Polyphase — 600 Volts AC Maximum — 50-60 Hertz
NEMA Continuous
Motor Max.
Size Current Ratings Volts HP
00
0
1
2
3
4
5
6
7
f
j
t
NEMA Type 4 & 4X
NEMA Type 1
Watertight, Dusttight
General
Brushed Stainless
Purpose
Steel Enclosure
Enclosure
(Sizes 0-5)f
Open Type
t
Coil
Voltage
Vertical
Horizontal
Type
Type
Type
Type
NEMA Type 12
NEMA Type 7 & 9
Dusttight &
Hazardous Locations
Driptight
Class I, Groups C & D
Industrial Use
Class II, Groups E, F & G
Enclosure
Bolted Type SPIN TOP ®
Type
Aluminum Type
Separate Controlj 120
...
SAO4V02S
SAG4V02S
208
...
SAO4V08
SAG4V08
200
11⁄2
230
11⁄2
240
...
SAO4V03
SAG4V03
Use Size 0
Use Size 0
Use Size 0
Use Size 0
460
2
480
...
SAO4V06
SAG4V06
575
2
600
...
SAO4V07
SAG4V07
Separate Controlj 120
SBO12V02S SBO4V02S
SBG4V02S
SBW14V02S
SBT49V02S
SBR9V02S
SBA4V02S
200
3
208
SBO12V08
SBO4V08
SBG4V08
SBW14V08
SBT49V08
SBR9V08
SBA4V08
230
3
240
SBO12V03
SBO4V03
SBG4V03
SBW14V03
SBT49V03
SBR9V03
SBA4V03
18
460
5
480
SBO12V06
SBO4V06
SBG4V06
SBW14V06
SBT49V06
SBR9V06
SBA4V06
575
5
600
SBO12V07
SBO4V07
SBG4V07
SBW14V07
SBT49V07
SBR9V07
SBA4V07
Separate Controlj 120
SCO7V02S
SCO8V02S
SCG8V02S
SCW14V02S
SCT49V02S
SCR9V02S
SCA4V02S
1
200
7 ⁄2
208
SCO7V08
SCO8V08
SCG8V08
SCW14V08
SCT49V08
SCR9V08
SCA4V08
27
240
SCO7V03
SCO8V03
SCG8V03
SCW14V03
SCT49V03
SCR9V03
SCA4V03
230
71⁄2
460
10
480
SCO7V06
SCO8V06
SCG8V06
SCW14V06
SCT49V06
SCR9V06
SCA4V06
575
10
600
SCO7V07
SCO8V07
SCG8V07
SCW14V07
SCT49V07
SCR9V07
SCA4V07
Separate Controlj 120
SDO1V02S
SDO2V02S
SDG2V02S
SDW11V02S
SDT43V02S
SDR3V02S
SDA1V02S
200
10
208
SDO1V08
SDO2V08
SDG2V08
SDW11V08
SDT43V08
SDR3V08
SDA1V08
45
230
15
240
SDO1V03
SDO2V03
SDG2V03
SDW11V03
SDT43V03
SDR3V03
SDA1V03
460
25
480
SDO1V06
SDO2V06
SDG2V06
SDW11V06
SDT43V06
SDR3V06
SDA1V06
575
25
600
SDO1V07
SDO2V07
SDG2V07
SDW11V07
SDT43V07
SDR3V07
SDA1V07
Separate Controlj 120
SEO1V02S
SEO2V02S
SEG2V02S
SEW11V02S
SET43V02S
SER3V02S
SEA1V02S
200
25
208
SEO1V08
SEO2V08
SEG2V08
SEW11V08
SET43V08
SER3V08
SEA1V08
90
230
30
240
SEO1V03
SEO2V03
SEG2V03
SEW11V03
SET43V03
SER3V03
SEA1V03
460
50
480
SEO1V06
SEO2V06
SEG2V06
SEW11V06
SET43V06
SER3V06
SEA1V06
575
540
600
SEO1V07
SEO2V07
SEG2V07
SEW11V07
SET43V07
SER3V07
SEA1V07
Separate Controlj 120
SFO1V02S
SFO3V02S
SFG3V02S
SFW11V02S
SFA1V02S
200
40
208
SFO1V08
SFO3V08
SFG3V08
SFW11V08
SFA1V08
135
230
50
240
SFO1V03
SFO3V03
SFG3V03
SFW11V03
...
...
SFA1V03
460
100
480
SFO1V06
SFO3V06
SFG3V06
SFW11V06
SFA1V06
575
100
600
SFO1V07
SFO3V07
SFG3V07
SFW11V07
SFA1V07
Separate Controlj 120
SGO1V02S SGO3V02S SGG3V02S
SGW11V02S
SGA1V02S
200
75
208
SGO1V08
SGO3V08
SGG3V08
SGW11V08
SGA1V08
270
230
100
240
SGO1V03
SGO3V03
SGG3V03
SGW11V03
...
...
SGA1V03
460
200
480
SGO1V06
SGO3V06
SGG3V06
SGW11V06
SGA1V06
575
200
600
SGO1V07
SGO3V07
SGG3V07
SGW11V07
SGA1V07
Separate Controlj 120
SHO1V02S
SHG1V02S
SHW1V02S
SHA1V02S
200
150
208
SHO1V08
SHG1V08
SHW1V08
SHA1V08
540
...
...
...
230
200
240
SHO1V03
SHG1V03
SHW1V03
SHA1V03
460
400
480
SHO1V06
SHG1V06
SHW1V06
SHA1V06
575
400
600
SHO1V07
SHG1V07
SHW1V07
SHA1V07
Separate Controlj 120
SJO1V02S
SJG1V02S
SJW1V02S
SJA1V02S
200
—
208
SJO1V08
SJG1V08
SJW1V08
SJA1V08
810
...
...
...
230
300
240
SJO1V03
SJG1V03
SJW1V03
SJA1V03
460
600
480
SJO1V06
SJG1V06
SJW1V06
SJA1V06
575
600
600
SJO1V07
SJG1V07
SJW1V07
SJA1V07
Size 6 and 7 are rated NEMA Type 4 only.
120 Volt Polyphase contactors are wired for separate control.
Coil voltage code must be specified to order this product. Refer to standard coil voltage codes listed in selection table above or additional standard voltage codes below and insert as shown
in the HOW TO ORDER block.
9
Coil Voltage Codes
Voltage
60 Hz
50 Hz
24q
120
208
240
480
600
Specify
...
110
...
220
440
550
Specify
q
j
Code
V01jq
V02j
V08
V03
V06
V07
V99
24 V coils are not available on Sizes 4-7. On Sizes 00-3, where 24 V
coils are available, Form S (separate control) must be specified.
These voltage codes must include Form S (supplied at N.C.).
How to Order:
To Order Specify:
• Class Number
• Type Number
• Coil Voltage Code
• Form(s)
Catalog Number
Class
Type
Coil
Voltage
Code
Form(s)
8702
SCG8
VO2
P1S
Factory Modifications (FORMS)............... Refer to Catalog 9999CT9701
Application Data .....................................................................Page 33, 37
Dimensions ............................................................................Pages 34-36
Separate Enclosures (Class 9991)........... Refer to Catalog 9999CT9701
Replacement Parts (Class 9998) .............. Refer to Catalog 9999CT9701
Type S Accessories (Class 9999)............. Refer to Catalog 9999CT9701
29
5/98
© 1998 Square D All Rights Reserved
Full Voltage Reversing Contactors — NEMA
Selection – Class 8702
600 Volts AC Maximum — 50-60 Hertz
Continuous
Motor
NEMA
Current
Volts
Size
Ratings
Max.
HP
NEMA
Type 1
General
Purpose
Enclosure
Open Type
t
Type of
Coil
Motor
Voltage
Vertical
Horizontal
Type
Type
Type
NEMA Type 4 & 4X
Watertight,
Dusttight
Brushed Stainless
Steel Enclosure
Type
NEMA Type 12
NEMA Type 7 & 9
Dusttight &
Hazardous Locations
Driptight
Class I, Groups C & D
Industrial Use
Class II, Groups E, F & G
Enclosure
SPIN TOP ®
Bolted Type
Type
Type
2-Pole Single Phase
00
9
0
18
1
27
115
230
115
230
115
230
1⁄3
115
230
115
230
115
230
115
230
115
230
115
230
1⁄3
1
1
2
2
3
Single
Phase
3-Wire
120
240
120
240
120
240
...
...
SBO9V02
SBO9V03
SCO1V02
SCO1V03
SAO1V02
SAO1V03
SBO1V02
SBO1V03
SCO2V02
SCO2V03
SAG1V02
SAG1V03
SBG1V02
SBG1V03
SCG2V02
SCG2V03
4-Wire
Rep.-Ind.
4-Wire
Split Ph.
4-Wire
Rep.-Ind.
4-Wire
Split Ph.
4-Wire
Rep.-Ind.
4-Wire
Split Ph.
120
240
120
240
120
240
120
240
120
240
120
240
...
...
...
...
SBO10V02
SBO10V03
SBO11V02
SBO11V03
SCO3V02
SCO3V03
SCO5V02
SCO5V03
SAO2V02
SAO2V03
SAO3V02
SAO3V03
SBO2V02
SBO2V03
SBO3V02
SBO3V03
SCO4V02
SCO4V03
SCO6V02
SCO6V03
SAG2V02
SAG2V03
SAG3V02
SAG3V03
SBG2V02
SBG2V03
SBG3V02
SBG3V03
SCG4V02
SCG4V03
SCG6V02
SCG6V03
Use Size 0
Use Size 0
Use Size 0
Use Size 0
SBW11V02
SBW11V03
SCW11V02
SCW11V03
SBT46V02
SBT46V03
SCT46V02
SCT46V03
SBR6V02
SBR6V03
SCR6V02
SCR6V03
SBA1V02
SBA1V03
SCA1V02
SCA1V03
Use Size 0
Use Size 0
Use Size 0
Use Size 0
Use Size 0
Use Size 0
Use Size 0
Use Size 0
SBW12V02
SBW12V03
SBW13V02
SBW13V03
SCW12V02
SCW12V03
SCW13V02
SCW13V03
SBT47V02
SBT47V03
SBT48V02
SBT48V03
SCT47V02
SCT47V03
SCT48V02
SCT48V03
SBR7V02
SBR7V03
SBR8V02
SBR8V03
SCR7V02
SCR7V03
SCR8V02
SCR8V03
SBA2V02
SBA2V03
SBA3V02
SBA3V03
SCA2V02
SCA2V03
SCA3V02
SCA3V03
3-Pole Single Phase
00
9
0
18
1
27
1
1⁄3
1
1
2
1
2
2
3
2
3
4-Pole Polyphase
0
1
2
3
4
t
SBR10V02S
SBA5V02S
Separate Control
120
SBO13V02S SBO5V02S SBG5V02S SBW15V02S
200
3
208
SBO13V08
SBO5V08
SBG5V08
SBW15V08
SBA5V08
Consult Local SBR10V08
230
3
240
SBO13V03
SBO5V03
SBG5V03
SBW15V03
SBR10V03
SBA5V03
Square D
460
5
480
SBO13V06
SBO5V06
SBG5V06
SBW15V06
Field Office
SBR10V06
SBA5V06
575
5
600
SBO13V07
SBO5V07
SBG5V07
SBW15V07
SBR10V07
SBA5V07
SCR10V02S SCA5V02S
Separate Control
120
SCO9V02S SCO10V02S SCG10V02S SCW15V02S
1
200
7 ⁄2
Consult Local SCR10V08
208
SCO9V08
SCO10V08 SCG10V08 SCW15V08
SCA5V08
Square D
27
230
71⁄2
240
SCO9V03
SCO10V03 SCG10V03 SCW15V03
SCR10V03
SCA5V03
Field Office
460
10
480
SCO9V06
SCO10V06 SCG10V06 SCW15V06
SCR10V06
SCA5V06
575
10
600
SCO9V07
SCO10V07 SCG10V07 SCW15V07
SCR10V07
SCA5V07
SDR4V02S
SDA2V02S
Separate Control
120
SDO4V02S SDG4V02S SDW12V02S
200
10
208
SDO4V08
SDG4V08
SDW12V08
SDA2V08
Consult Local SDR4V08
2 Phase
230
15
240
SDO4V03
SDG4V03
SDW12V03
SDR4V03
SDA2V03
Square D
45
...
2 Wire
460
25
480
SDO4V06
SDG4V06
SDW12V06
SDR4V06
SDA2V06
Field Office
575
25
600
SDO4V07
SDG4V07
SDW12V07
SDR4V07
SDA2V07
Separate Control
120
SEO4V02S SEG4V02S SEW12V02S
SEA2V02S
200
25
208
SEO4V08
SEG4V08
SEW12V08
SEA2V08
230
30
240
SEO4V03
SEG4V03
SEW12V03
SEA2V03
90
...
...
...
460
50
480
SEO4V06
SEG4V06
SEW12V06
SEA2V06
575
50
600
SEO4V07
SEG4V07
SEW12V07
SEA2V07
Separate Control
120
SFO4V02S SFG4V02S SFW12V02S
SFA2V02S
200
40
208
SFO4V08
SFG4V08
SFW12V08
SFA2V08
135
230
50
240
...
SFO4V03
SFG4V03
SFW12V03
...
...
SFA2V03
460
100
480
SFO4V06
SFG4V06
SFW12V06
SFA2V06
575
100
600
SFO4V07
SFG4V07
SFW12V07
SFA2V07
Coil voltage code must be specified to order this product. Refer to standard coil voltage codes listed in selection table above or additional standard voltage codes below and insert as shown
in the HOW TO ORDER block.
18
Coil Voltage Codes
Voltage
60 Hz
50 Hz
24q
120
208
240
480
600
Specify
...
110
...
220
440
550
Specify
q
j
Code
V01j
V02j
V08
V03
V06
V07
V99
File E78351
CCN NLDX
File LR60905
Class 3211-04
24 V coils are not available on Sizes 4-7. On Sizes 00-3, where 24 V
coils are available, Form S (separate control) must be specified.
These voltage codes must include Form S (supplied at N.C.).
How to Order:
To Order Specify:
Factory Modifications (FORMS) ...............Refer to Catalog 9999CT9701
Application Data .................................................................... Page 33, 37
Dimensions ........................................................................... Pages 34-36
Separate Enclosures (Class 9991) ...........Refer to Catalog 9999CT9701
Replacement Parts (Class 9998) ..............Refer to Catalog 9999CT9701
Type S Accessories (Class 9999).............Refer to Catalog 9999CT9701
• Class Number
• Type Number
• Coil Voltage Code
• Form(s)
Catalog Number
Class
Type
Coil
Voltage
Code
Form(s)
8702
SCG2
VO2
P1S
30
© 1998 Square D All Rights Reserved
5/98
Full Voltage Reversing Starters — NEMA
Selection – Class 8736
3-Pole Polyphase—Three Thermal Units Required
Continuous
Motor
NEMA
Current
Volts
Size
Ratings
00
0
1
2
3
4
5
6
7
f
j
t
Max.
HP
NEMA
Type 1
General
Purpose
Enclosure
Open Type
t
Coil
Voltage
Vertical
Horizontal
Type
Type
Type
NEMA Type 4 & 4X
Watertight, Dusttight
Brushed Stainless
Steel Enclosure
(Size 0-5)f
NEMA Type 7 & 9
Hazardous Locations
Class I, Groups C & D
Class II, Groups E, F & G
Type
Bolted Type
NEMA Type 12
Dusttight & Driptight
Industrial Use
Enclosure
SPIN TOP ®
Type
Type
Separate Controlj
120
SAO16V02S SAG16V02S
208
SAO16V08
SAG16V08
200
11⁄2
230
11⁄2
240
...
SAO16V03
SAG16V03
Use Size 0
Use Size 0
Use Size 0
Use Size 0
460
2
480
SAO16V06
SAG16V06
575
2
600
SAO16V07
SAG16V07
Separate Controlj
120
SBO10V02S SBO4V02S SBG4V02S SBW14V02S
SBT49V02S
SBR9V02S
SBA4V02S
200
3
208
SBO10V08
SBO4V08
SBG4V08
SBW14V08
SBT49V08
SBR9V08
SBA4V08
230
3
240
SBO10V03
SBO4V03
SBG4V03
SBW14V03
SBT49V03
SBR9V03
SBA4V03
18
460
5
480
SBO10V06
SBO4V06
SBG4V06
SBW14V06
SBT49V06
SBR9V06
SBA4V06
575
5
600
SBO10V07
SBO4V07
SBG4V07
SBW14V07
SBT49V07
SBR9V07
SBA4V07
Separate Controlj
120
SCO7V02S SCO8V02S SCG8V02S SCW14V02S
SCT49V02S
SCR9V02S
SCA4V02S
200
71⁄2
208
SCO7V08
SCO8V08
SCG8V08
SCW14V08
SCT49V08
SCR9V08
SCA4V08
27
240
SCO7V03
SCO8V03
SCG8V03
SCW14V03
SCT49V03
SCR9V03
SCA4V03
230
71⁄2
460
10
480
SCO7V06
SCO8V06
SCG8V06
SCW14V06
SCT49V06
SCR9V06
SCA4V06
575
10
600
SCO7V07
SCO8V07
SCG8V07
SCW14V07
SCT49V07
SCR9V07
SCA4V07
Separate Controlj
120
SDO1V02S SDO2V02S SDG2V02S SDW11V02S
SDT43V02S
SDR3V02S
SDA1V02S
200
10
208
SDO1V08
SDO2V08
SDG2V08
SDW11V08
SDT43V08
SDR3V08
SDA1V08
45
230
15
240
SDO1V03
SDO2V03
SDG2V03
SDW11V03
SDT43V03
SDR3V03
SDA1V03
460
25
480
SDO1V06
SDO2V06
SDG2V06
SDW11V06
SDT43V06
SDR3V06
SDA1V06
575
25
600
SDO1V07
SDO2V07
SDG2V07
SDW11V07
SDT43V07
SDR3V07
SDA1V07
Separate Controlj
120
SEO1V02S SEO2V02S SEG2V02S SEW11V02S
SET43V02S
SER3V02S
SEA1V02S
200
25
208
SEO1V08
SEO2V08
SEG2V08
SEW11V08
SET43V08
SER3V08
SEA1V08
90
230
30
240
SEO1V03
SEO2V03
SEG2V03
SEW11V03
SET43V03
SER3V03
SEA1V03
460
50
480
SEO1V06
SEO2V06
SEG2V06
SEW11V06
SET43V06
SER3V06
SEA1V06
575
50
600
SEO1V07
SEO2V07
SEG2V07
SEW11V07
SET43V07
SER3V07
SEA1V07
Separate Controlj
120
SFO1V02S SFO3V02S SFG3V02S SFW11V02S
SFA1V02S
200
40
208
SFO1V08
SFO3V08
SFG3V08
SFW11V08
SFA1V08
135
230
50
240
SFO1V03
SFO3V03
SFG3V03
SFW11V03
...
...
SFA1V03
460
100
480
SFO1V06
SFO3V06
SFG3V06
SFW11V06
SFA1V06
575
100
600
SFO1V07
SFO3V07
SFG3V07
SFW11V07
SFA1V07
Separate Controlj
120
SGO1V02S SGO3V02S SGG3V02S SGW11V02S
SGA1V02S
200
75
208
SGO1V08
SGO3V08
SGG3V08
SGW11V08
SGA1V08
270
230
100
240
SGO1V03
SGO3V03
SGG3V03
SGW11V03
...
...
SGA1V03
460
200
480
SGO1V06
SGO3V06
SGG3V06
SGW11V06
SGA1V06
575
200
600
SGO1V07
SGO3V07
SGG3V07
SGW11V07
SGA1V07
Separate Controlj
120
SHO1V02S SHG1V02S SHW1V02S
SHA1V02S
200
150
208
SHO1V08
SHG1V08
SHW1V08
SHA1V08
540
...
...
...
230
200
240
SHO1V03
SHG1V03
SHW1V03
SHA1V03
460
400
480
SHO1V06
SHG1V06
SHW1V06
SHA1V06
575
400
600
SHO1V07
SHG1V07
SHW1V07
SHA1V07
Separate Controlj
120
SJO1V02S
SJG1V02S
SJW1V02S
SJA1V02S
200
—
208
SJO1V08
SJG1V08
SJW1V08
SJA1V08
810
...
...
...
230
300
240
SJO1V03
SJG1V03
SJW1V03
SJA1V03
460
600
480
SJO1V06
SJG1V06
SJW1V06
SJA1V06
575
600
600
SJO1V07
SJG1V07
SJW1V07
SJA1V07
Size 6 and 7 are sheet steel rated NEMA Type 4 only.
120 Volt Polyphase starters are wired for separate control.
Coil voltage code must be specified to order this product. Refer to standard coil voltage codes listed in selection table above or additional standard voltage codes below and insert as shown
in the HOW TO ORDER block.
9
Coil Voltage Codes
Voltage
60 Hz
50 Hz
24q
120
208
240
480
600
Specify
...
110
...
220
440
550
Specify
q
Code
V01
V02
V08
V03
V06
V07
V99
24 V coils are not available on Sizes 4-7. On Sizes 00-3, where 24 V
coils are available, Form S (separate control) must be specified.
How to Order:
To Order Specify:
• Class Number
• Type Number
• Coil Voltage Code
• Form(s)
Catalog Number
Class
Type
Coil
Voltage
Code
Form(s)
8736
SCG8
VO2
P1S
Factory Modifications (FORMS)............... Refer to Catalog 9999CT9701
Application Data .....................................................................Page 33, 37
Dimensions ............................................................................Pages 34-36
Separate Enclosures (Class 9991)........... Refer to Catalog 9999CT9701
Replacement Parts (Class 9998) .............. Refer to Catalog 9999CT9701
Type S Accessories (Class 9999)............. Refer to Catalog 9999CT9701
31
5/98
© 1998 Square D All Rights Reserved
Full Voltage Reversing Starters — NEMA
Selection – Class 8736
600 Volts AC Maximum — 50-60 Hertz
Continuous
Motor
NEMA
Current
Volts
Size
Ratings
Max.
HP
NEMA
Type 1
General
Purpose
Enclosure
Open Type
t
Type of
Coil
Motor
Voltage
Vertical
Horizontal
Type
Type
Type
2-Pole Single Phase — 1 Thermal Unit Required
1⁄3
115
00
9
230
1
Single
115
1
0
18
Phase
230
2
3-Wire
115
2
1
27
230
3
3-Pole Single Phase — 1 Thermal Unit Required
1⁄3
4-Wire
115
230
1
Rep.-Ind.
00
9
1⁄3
115
4-Wire
230
1
Split Ph.
115
1
4-Wire
230
2
Rep.-Ind.
0
18
115
1
4-Wire
230
2
Split Ph.
115
2
4-Wire
230
3
Rep.-Ind.
1
27
115
2
4-Wire
230
3
Split Ph.
4-Pole Polyphase — 2 Thermal Units Required
Separate Controlj
200
3
230
3
0
18
460
5
575
5
Separate Controlj
200
71⁄2
1
27
230
71⁄2
460
10
575
10
Separate Controlj
200
10
2 Phase
230
15
2
45
2 Wire
460
25
3
4
j
t
Type
120
240
120
240
120
240
...
...
SBO7V02
SBO7V08
SCO1V02
SCO1V08
SAO13V02
SAO13V08
SBO1V02
SBO1V08
SCO2V02
SCO2V08
SAG13V02
SAG13V08
SBG1V02
SBG1V08
SCG2V02
SCG2V08
120
240
120
240
120
240
120
240
120
240
120
240
...
...
...
...
SBO80V02
SBO8V08
SBO9V02
SBO9V08
SCO3V02
SCO3V08
SCO5V02
SCO5V08
SAO14V02
SAO14V08
SAO15V02
SAO15V08
SBO2V02
SBO2V08
SBO3V02
SBO3V08
SCO4V02
SCO4V08
SCO6V02
SCO6V08
SAG14V02
SAG14V08
SAG15V02
SAG15V08
SBG2V02
SBG2V08
SBG3V02
SBG3V08
SCG4V02
SCG4V08
SCG6V02
SCG6V08
120
208
240
480
600
120
208
240
480
600
120
208
240
480
600
120
208
240
480
600
120
208
240
480
600
SBO11V02S
SBO11V08
SBO11V03
SBO11V06
SBO11V07
SCO9V02S
SCO9V08
SCO9V03
SCO9V06
SCO9V07
SBO5V02S
SBO5V08
SBO5V03
SBO5V06
SBO5V07
SCO10V02S
SCO10V08
SCO10V03
SCO10V06
SCO10V07
SDO4V02S
SDO4V08
SDO4V03
SDO4V06
SDO4V07
SEO4V02S
SEO4V08
SEO4V03
SEO4V06
SEO4V07
SFO4V02S
SFO4V08
SFO4V03
SFO4V06
SFO4V07
SBG5V02S
SBG5V08
SBG5V03
SBG5V06
SBG5V07
SCG10V02S
SCG10V08
SCG10V03
SCG10V06
SCG10V07
SDG4V02S
SDG4V08
SDG4V03
SDG4V06
SDG4V07
SEG4V02S
SEG4V08
SEG4V03
SEG4V06
SEG4V07
SFG4V02S
SFG4V08
SFG4V03
SFG4V06
SFG4V07
...
NEMA Type 4 & 4X
Watertight,
Dusttight
Brushed Stainless
Steel Enclosure
NEMA Type 12
NEMA Type 7 & 9
Dusttight &
Hazardous Locations
Driptight
Class I, Groups C & D
Industrial Use
Class II, Groups E, F & G
Enclosure
SPIN TOP ®
Bolted Type
Type
Type
Use Size 0
Use Size 0
Use Size 0
Use Size 0
SBW11V02
SBW11V08
SCW11V02
SCW11V08
SBT46V02
SBT46V08
SCT46V02
SCT46V08
SBR6V02
SBR6V08
SCR6V02
SCR6V08
SBA1V02
SBA1V08
SCA1V02
SCA1V08
Use Size 0
Use Size 0
Use Size 0
Use Size 0
Use Size 0
Use Size 0
Use Size 0
Use Size 0
SBW12V02
SBW12V08
SBW13V02
SBW13V08
SCW12V02
SCW12V08
SCW13V02
SCW13V08
SBT47V02
SBT47V08
SBT48V02
SBT48V08
SCT47V02
SCT47V08
SCT48V02
SCT48V08
SBR7V02
SBR7V08
SBR8V02
SBR8V08
SCR7V02
SCR7V08
SCR8V02
SCR8V08
SBA2V02
SBA2V08
SBA3V02
SBA3V08
SCA2V02
SCA2V08
SCA3V02
SCA3V08
SBR10V02S
SBR10V08
SBR10V03
SBR10V06
SBR10V07
SCR10V02S
SCR10V08
SCR10V03
SCR10V06
SCR10V07
SDR4V02S
SDR4V08
SDR4V03
SDR4V06
SDR4V07
SBA5V02S
SBA5V08
SBA5V03
SBA5V06
SBA5V07
SCA5V02S
SCA5V08
SCA5V03
SCA5V06
SCA5V07
SDA2V02S
SDA2V08
SDA2V03
SDA2V06
SDA2V07
SEA2V02S
SEA2V08
SEA2V03
SEA2V06
SEA2V07
SFA2V02S
SFA2V08
SFA2V03
SFA2V06
SFA2V07
SBW15V02S
SBW15V08
SBW15V03
SBW15V06
SBW15V07
SCW15V02S
SCW15V08
SCW15V03
SCW15V06
SCW15V07
SDW12V02S
SDW12V08
SDW12V03
SDW12V06
SDW12V07
SEW12V02S
SEW12V08
SEW12V03
SEW12V06
SEW12V07
SFW12V02S
SFW12V08
SFW12V03
SFW12V06
SFW12V07
Consult Local
Square D
Field Office
Consult Local
Square D
Field Office
Consult Local
Square D
Field Office
575
25
Separate Controlj
200
25
230
30
90
...
...
...
460
50
575
50
Separate Controlj
200
40
135
230
50
...
...
...
460
100
575
100
120 Volt starters are wired for separate control.
Coil voltage code must be specified to order this product. Refer to standard coil voltage codes listed in selection table above or additional standard voltage codes below and insert as shown
in the HOW TO ORDER block.
Coil Voltage Codes
Voltage
60 Hz
50 Hz
24q
120
208
240
480
600
Specify
...
110
...
220
440
550
Specify
q
Code
V01
V02
V08
V03
V06
V07
V99
File E78351
CCN NLDX
File LR60905
Class 3211-04
24 V coils are not available on Sizes 4-7. On Sizes 00-3, where 24 V
coils are available, Form S (separate control) must be specified.
How to Order:
To Order Specify:
Factory Modifications (FORMS) ...............Refer to Catalog 9999CT9701
Application Data .................................................................... Page 33, 37
Dimensions ........................................................................... Pages 34-36
Separate Enclosures (Class 9991) ...........Refer to Catalog 9999CT9701
Replacement Parts (Class 9998) ..............Refer to Catalog 9999CT9701
Type S Accessories (Class 9999).............Refer to Catalog 9999CT9701
• Class Number
• Type Number
• Coil Voltage Code
• Form(s)
Catalog Number
Class
Type
Coil
Voltage
Code
Form(s)
8736
SCG8
VO2
P1S
32
© 1998 Square D All Rights Reserved
5/98
Full Voltage Reversing Contactors and Starters — NEMA
Application Data – Class 8702, 8736
Power Contact Ratings
Auxiliary Units
All contactors are rated in accordance with NEMA
standards. The ratings shown in the tables on
Pages 29-32 are for normal service. For complete
data on power contact ratings, refer to Class 8536
Section.
The table below shows the maximum number of
auxiliary units (in addition to the holding circuit
and interlocking contacts) that can be added to
either the forward or reverse contactor or starter.
Maintenance of Equipment
Class 9998 repair parts kits are available for all
Class 8702 contactors and Class 8736 starters.
Service bulletins with a complete list of
replaceable parts are supplied with all devices.
See Page 15.
The following table gives the proper size control
transformer to be used with a given reversing
device, with or without additional auxiliary
contacts or timer. For factory addition of control
transformers, see Factory Modifications (Forms)
section.
Transformers
Class 9070
Type
No. of
Poles
Type
0, 1 & 2
SB, SC & SD
Any
T100 or GO2
3
T1500 or GO3
3
SE
4&5
T300
4
SF
Any
T300
5
SG
Any
T500
6&7
SH & SJ
Any
See Page 16
Example:
X
1
O
No. of Poles
of Basic
Contactor
00
(SA)
2 or 3
2 single circuit auxiliary contacts
(N.O. or N.C.)
4 single circuit auxiliary contactsq
(N.O. or N.C.)
0, 1 & 2
(SB, SC
& SD)
Control Transformer Selection
NEMA Size
NEMA Size
(Type)
Maximum number of
auxiliary units on each
contactor, forward or
reverse, (in addition to
internal holding circuit and
interlocking contacts).
1
2 or 3
2 single circuit auxiliary contacts
(N.O. or N.C.)
4
3, 4, 5, 6, & 7
(SE, SF, SG,
SH, & SJ)
q
1 single circuit auxiliary contact
(N.O. or N.C.) plus 1 attached timer
(ON or OFF delay).
2 single circuit auxiliary contacts
(N.O. or N.C.)
Any
1 single circuit auxiliary contact plus
1 attached timer (ON or OFF delay).
When adding 4 external auxiliary contacts to one Size 0 or 1
contactor, remove one of the return springs.
Factory Installed Auxiliary Contacts
Additional auxiliary contacts may be factory or
field added to any Type 3 contactor or starter. See
table above for maximum number of auxiliary
units. The table below lists the Form designations
for factory installed auxiliary contacts. See Class
9999 for field modification kits.
O
Number of N.C. auxiliary contacts on right hand (Reverse) contactor.
Number of N.O. auxiliary contacts on right hand (Reverse) contactor.
Number of N.C. auxiliary contacts on left hand (Forward) contactor.
Number of N.O. auxiliary contacts on left hand (Forward) contactor.
Basic Form Designation.
Additional Auxiliary Contacts on R.H. Contactor (Reverse Contactor)
Standard
(No Additional
Auxiliary Contacts)
Additional
Auxiliary
Contacts on
L.H.
Contactor
(Forward
Contactor)
Standard
(No Additional
Auxiliary Contacts)
1 N.O.
1 N.C.
2 N.O.
1 N.O.-1 N.C.
2 N.C.
X0010
X0001
X0020
X0011
X0002
1 N.O.
X1000
X1010
X1001
X1020
X1011
X1002
1 N.C.
X0100
X0110
X0101
X0120
X0111
X0102
2 N.O.
X2000
X2010
X2001
X2020
X2011
X2002
1 N.O.-1 N.C.
X1100
X1110
X1101
X1120
X1111
X1102
2 N.C.
X0200
X0210
X0201
X0220
X0211
X0202
33
5/98
© 1998 Square D All Rights Reserved
Full Voltage Reversing Contactors and Starters — NEMA
Approximate Dimensions – Class 8702, 8736
Open Type — 2 or 3-Pole Only
A
D
F
G
E
A
D
C
E
G
F
C
H
I
B
H B
RESET
J
J
Class
K
NEMA
Type
Size
Mounting
Figure Dimensions — Inches/mm
Number A
B
C
D
00
Horizontal
1
7.13
181
5.00
127
5.31
135
1
7.13
181
5.00
127
5.31
135
1t
5.41
137
9.22
234
5.31
135
1
9.00
229
6.88
175
6.03
153
1t
6.75
171
11.38
289
6.03
153
1
12.72
323
7.97
202
1t
7.20
183
0
1
SAO
SBO
SCO
Horizontal
Vertical
Horizontal
2
Horizontal
3
Vertical
Horizontal
4
Horizontal
7
00
0
1
SHO
SJO
SAO
SBO
SCO
Horizontal
Horizontal
Horizontal
Horizontal
Vertical
Horizontal
2
Horizontal
Vertical
Horizontal
Horizontal
7
t
L
M
Weight
(Lbs)
...
3.41
87
.47
12
4.34
110
.19
5
5.50
140
.91
23
...
...
12
...
...
3.41
87
.47
12
4.34
110
.19
5
5.50
140
.91
23
...
...
12
5.03
128
.22
6
...
.61
15
8.00
203
.61
15
5.03
128
.22
6
...
...
12
...
...
4.50
114
.38
10
5.63
143
.25
6
6.00
152
1.50
38
...
...
16
6.25
159
.25
6
...
.50
13
10.38
264
.50
13
6.25
159
.25
6
...
...
16
7.00
178
11.75
298
.48
12
...
.48
12
7.00
178
.48
12
11.75
298
.48
12
...
...
35
19.00
483
7.00
178
6.25
159
.48
12
...
1.02
26
17.00
432
.98
25
6.25
159
.48
12
...
...
35
1
14.25
362
11.69
297
7.00
178
13.25
337
.50
13
...
.50
13
8.00
203
1.84
47
13.25
337
.50
13
...
...
45
1t
7.97
202
23.91
607
7.00
178
7.00
178
.48
12
...
1.81
46
20.25
514
1.19
30
7.00
178
.48
12
...
...
45
1
19.31
490
16.19
411
9.38
238
18.00
457
.66
17
...
1.03
26
14.00
356
1.16
29
18.00
457
.66
17
...
...
98
1t
10.75
273
34.41
874
9.38
238
9.50
241
.63
16
...
1.25
32
32.00
813
1.16
29
9.50
241
.63
16
...
...
98
1
22.38
568
28.05
712
9.52
242
18.00
457
.77
20
...
3.83
97
21.19
538
3.03
77
18.00
457
.77
20
...
...
195
1
24.25
616
37.25
946
13.81
351
19.75
502
1.52
39
...
...
30.00
762
...
...
...
...
...
310
2
7.13
181
6.91
176
5.31
135
...
3.41
87
.47
12
4.34
110
6.22
158
4.53
115
5.06
129
.66
17
...
13
2
7.13
181
6.91
176
5.31
135
...
...
3.41
87
.47
12
4.34
110
6.22
158
4.53
115
5.06
129
.66
17
...
13
2t
5.41
137
11.52
293
5.31
135
5.03
128
.22
6
...
.61
15
8.00
203
10.70
272
2.52
64
5.06
129
.22
6
5.03
128
13
2
9.00
229
8.50
216
6.03
153
...
...
4.50
114
.38
10
5.63
143
7.50
191
5.00
127
5.16
131
1.50
38
...
18
2t
6.75
171
13.48
342
6.03
153
6.25
159
.25
6
...
.78
20
10.38
264
12.97
329
3.13
80
5.16
131
.25
6
6.00
152
18
2
12.72
323
11.72
298
7.00
178
11.75
298
.48
12
...
.48
12
10.75
273
10.75
273
11.75
298
6.25
159
.48
12
11.75
298
38
2t
7.31
186
22.25
565
7.00
178
6.25
159
.48
12
...
1.02
26
20.75
527
...
6.25
159
6.25
159
.48
12
6.25
159
38
2
14.25
362
14.59
371
7.00
178
13.25
337
.50
13
...
1.84
47
12.25
311
12.25
311
13.25
337
6.25
159
.50
13
13.25
337
48
2t
7.97
202
26.81
681
7.00
178
7.00
178
.48
12
...
1.84
47
24.50
622
...
4.05
103
6.25
159
.48
12
7.00
178
48
2
19.31
490
20.91
531
9.38
238
18.00
457
.66
17
...
1.28
33
19.00
483
19.00
483
18.00
457
6.63
168
.63
16
18.00
457
115
2t
10.75
273
39.16
995
9.38
238
9.50
241
.66
17
...
1.28
33
37.25
946
37.25
946
9.50
241
6.63
168
.63
16
9.50
241
115
2
22.38
568
28.05
712
9.52
242
18.00
457
.77
20
...
3.83
97
21.19
538
3.03
77
18.00
457
.77
20
...
...
200
1
24.25
616
37.25
946
13.81
351
19.75
502
1.52
39
...
30.00
762
...
...
...
...
...
315
SGO
Vertical
6
K
SFO
Vertical
5
J
SEO
8736
4
I
SDO
Vertical
3
H
SGO
Vertical
6
G
SFO
Vertical
5
F
SEO
8702
SHO
SJO
Horizontal
Horizontal
K
E
SDO
Vertical
L
M
I
...
...
...
Vertical type design differs from that shown on the corresponding NEMA size horizontal figure, but dimensions listed apply to that figure.
34
© 1998 Square D All Rights Reserved
5/98
Full Voltage Reversing Contacators and Starters — NEMA
Approximate Dimensions – Class 8702, 8736
A
H
(4) I Dia.
Mounting Holes
A
C
B
B
G
RESET
E
F
D
C
1.50
H
38
Figure 4
D
A
E
G
D
FC
B
G
(4) L Dia.
Mounting Holes
I
WX
J
H
K
Figure 6
D
A
E
D
G
Figure 5
NEMA Type 1
Dimensions — Inches/mm
C
NEMA Class Fig.
A
B
D
Size No.
No.
8702
8736
IN
mm IN
mm IN
mm IN
mm IN
Wt (Lbs)
E
F
G
mm IN mm IN mm IN
H
B
G
(4) J Dia.
Mounting Holes
00, 0 j 8702 &
11.88 302 11.88 302 7.41 188 7.53 191 9.75 248 1.06 27 1.06 27 9.75 248 1.06
8736 4
1j
8702
&
2j
14.88 378 14.13 359 7.56 192 7.66 195 12.75 324 1.06 27 1.06 27 12.00 305 1.06
8736 4
3t
8702 & 4
18.16
461 29.16 741 9.25 235 9.25 235 15.50 394 1.33 34 1.33 34 26.50 673 1.33
8736
4t
8702
&
5
35.22 895 46.22 1174 12.81 325 12.93 328 31.00 787 2.11 54 2.11 54 42.00 1067 2.11
8736 4
8702
&
6
36.22 920 62.22 1580 19.47 495 19.47 495
8736 5
Floor Mounting
8702 & 5
7
34.50
876 93.00 2362 23.50 597 23.50 597
8736
j
Standard enclosure has space for a fused control transformer, Form F4T, on Sizes 0-2, except for Size 0 & 1 4-Pole.
t
3-Pole only.
27
.31 8
16
17
27
.31 8
24
25
34
.44 11
95
98
54
.56 14
298
315
400
405
...
...
NEMA Type 4 & 4X – Stainless Steelq
NEMA Class
Size
Number
0j
1j
2j
I
3t
4t
H
Figure 7
8702 8736
mm IN mm IN mm
Dimensions — Inches/mm
FC
I
5
6
7
j
t
q
Fig.
No.
A
B
C
D
E
Weight
(Lbs)
Hub Dia.
F
G
H
I
J
K
L
W
X
Bot. Top & 8702 8736
Only Bot.
12.63 7.81
14.69 2.56
7.50 13.50 .59
3.88
18.41 1.66
2.31
.31
3⁄4
321 198
373
65
191
343
15
99
468
42
59
8
14.88
8.25
15.75
12.56
9.75
15.00
.38
3.88
20.88
1.72
2.63
.31
3⁄4
8702 & 8736 6
378 210
400
319
248
381
10
99
530
44
67
8
18.16
8.75
32.22
3.08
12.00
30.50
.88
3.69
26.72
2.56
3.19
.44
3⁄4
8702
6
461 222
818
78
305
775
22
94
679
65
81
11
18.16 9.56
32.22 3.08
12.00 30.50 .88
4.50
26.72 2.56
3.19
.44
3⁄4
8736
6
461 243
818
78
305
775
22
114
679
65
81
11
35.22
12.13
49.22
4.11
27.00
48.00
.63
4.59
45.81
2.97
3.50
.56
3⁄4
8702
6
895 308
1250 104
686
1219 16
117
1164 75
89
14
35.22
12.94
49.22
4.11
27.00
48.00
.63
5.41
45.81
2.97
3.50
.56
3⁄4
8736
6
895 329
1250 104
686
1219 16
137
1164 75
89
14
36.22 70.13 19.47
8702 & 8736 5
920 1781 495
Floor Mounting
34.50 101.00 23.50
8702 & 8736 5
876 2565 597
Standard enclosure has space for a fused control transformer, Form F4T, on Sizes 0-2, except for Size 0 & 1 4-Pole devices.
3-Pole only.
Size 6 & 7 are sheet steel enclosures and are rated NEMA Type 4 only.
8702 & 8736 6
1
25
26
11⁄2
33
35
21⁄2
96
...
21⁄2
...
99
31⁄2
300
...
31⁄2
...
317
500
505
...
...
NEMA Type 12
Dimensions — Inches/mm
NEMA Class Fig.
A
B
C
D
Size Number No.
IN
mm IN
mm IN
mm IN
0j
1j
2j
3t
4t
5
6
7
j
t
E
mm IN
F
mm IN
G
H
mm IN mm IN
I
mm IN
Wt (Lbs)
J
8702 8736
mm IN mm
8702 &
7
11.88 302 7.75 197 13.75 349 2.56 65 6.75 171 12.75 324 .50 13 3.66 93 18.13 461 .31
8736
8702 &
7
14.88 378 7.88 200 16.00 406 2.56 65 9.75 248 15.00 381 .50 13 3.66 93 21.25 540 .31
8736
8702
7
18.16 461 9.25 235 31.50 800 3.08 78 12.00 305 30.50 775 .50 13 3.69 93 26.72 679 .44
8736
7
18.16 461 9.56 243 31.50 800 3.08 78 12.00 305 30.50 775 .50 13 4.50 114 26.72 679 .44
8702
7
35.22 895 13.13 334 49.00 1245 4.13 105 27.00 686 48.00 1219 .50 13 5.31 135 45.88 1165 .56
8736
7
35.22 895 13.94 354 49.00 1245 4.13 105 27.00 686 48.00 1219 .50 13 6.13 156 45.88 1165 .56
8702 &
5
36.22 920 62.22 1580 19.47 495
8736
Floor Mounting
8702 &
5
34.50 876 93.00 2362 23.50 597
8736
Standard enclosure has space for a fused control transformer, Form F4T, on Sizes 0-2, except for Size 0 & 1 4-Pole devices.
3-Pole only.
8
23
24
8
31
32
11
11
14
14
96
...
302
...
...
99
...
319
490
495
...
...
35
5/98
© 1998 Square D All Rights Reserved
Full Voltage Reversing Contactors and Starters — NEMA
Approximate Dimensions – Class 8702, 8736
NEMA Type 4X — Watertight and Corrosion Resistant
Glass Polyester Enclosure
A
E
NEMA
Class
Size
C
F
Type
A
No. of
Fig.
Poles
IN
B
C
mm IN
mm IN
E
F
mm IN
mm IN
mm
0-2
SBW
8702/36 SCW
SDW
All
16.88 429
9.78
248
22.75 578
10.13 257
21.50 546
0-2 t
SBW
8702/36 SCW
SDW
All
24.63 626
11.94 303
27.00 686
17.88 454
25.75 654
3-4
8702/36
SEW
SPW
All
25.81 656
11.94 303
33.50 851
18.50 470
32.25 819
3-4 t
8702/36
SEW
SPW
All
32.00 813
12.13 308
39.31 998
23.88 607
38.13 969
With control power transformer (Form F4T)
t
B
Figure 7
NEMA Type 7 & 9 Bolted Enclosure — Figure 8
Dimensions — Inches/mmc
NEMA
Size
Type
IN
mm
IN
mm
IN
mm
IN
mm
IN
mm
IN
mm
IN
mm
IN
mm
IN
mm
0-2
SBT
SCT
SDT
14.25
362
27.63
702
9.50
241
12.25
311
19.25
489
9.63
245
11.50
292
2.38
60
3.13
80
115
3-4 t
SET
SFT
24.50
622
45.63
1159
13.75
349
22.50
572
27.50
699
13.75
349
15.38
391
3.44
87
4.00
102
180
c
G
H
J
K
L
N
P
Q, R
Wt
(Lbs)
S, T, U, V
Dimensions shown for 2 or 3-Pole devices only.
V U
Space Required
To Remove
Top Cover
O
N
Circuit Breaker Handle not supplied
on Class 8502 or 8536
E
Q
H
1/2" NPT for Breather and Drain
L
Rear Seal
R
N
A
K
(2) "L" Pipe
Tap Top and
Bottom
R
S T
G
G
C
F
L
D
B
Threaded
Cover
Enclosure
J
P
Mounting for 4 Bolts
M
J
T
Mtg. Holes
and/or Slots (3)
Circuit Breaker
Operational Handle –
Combination Form Only
P
(Add 1.00 Inch To
Overall Width)
Overload
Reset
Figure 8
H S
K
Figure 9
Space Required To
Remove Bottom Cover
NEMA 7 & 9 SPIN TOP ® Enclosure — Figure 9
Dimensions — Inches/mm
NEMA
Type
Size
A
Bt
Bj
Ct
Cj
D
Et
Ej
0-1
SBR
SCR
12.00 41.06 46.13 68.06 79.13 16.75 7.25
305
1043 1172 1729 2010 425
184
2
SDR
16.13 48.50 50.50 81.50 85.00 20.25 12.13 9.13
410
1232 1283 2070 2159 514
308
232
3
SER
Consult Local Square D Field Office
t
j
F
12.25 7.69
311
195
8.63
219
Gt
Gj
Ht
Hj
Jt
Jj
K
26.13 26.13 3.00
664
664
76
9.00
229
24.00 24.00 8.50
610
610
216
27.75 32.75 8.00
705
832
203
4.50
114
M
N
P
R
2.06
52
9.38
238
5.25
133
1.50
38
.38
10
70
25.00 30.00 12.00 12.63 11.00 5.50
635
762
305
321
279
140
2.50
64
.38
10
100
Without control transformer.
With control transformer (Form F4T).
36
© 1998 Square D All Rights Reserved
Wt
(Lbs)
L
5/98
Full Voltage Contactors — NEMA
Application Data, Selection – Class 8702
Auxiliary Contact Units
Class 8702 Type WF
Reversing Vacuum
Contactor
Additional auxiliary contact units may be added to
the Size 4 and 5 reversing contactors in the field.
A maximum of 2 units may be added to the Size 4;
a maximum of 1 unit may be added to the Size 5.
No additional units may be added to the Size 6,
however, 1 N.O. and 1 N.C. circuit are available on
each forward and reverse contactor for customer
use.
GENERAL INFORMATION
Class 8702 Type W reversing vacuum contactors
are a new addition to the Square D line of
contactors. These reversing contactors are used
to switch capacitors, transformers and electric
motors where overload protection is separately
provided. Type W reversing vacuum contactors
are designed for operation at 600 Volts, 50/60
Hertz.
By design, these contactors are well suited to
heavy-duty applications in harsh environments.
The power contacts are sealed in ceramic tubes,
called vacuum interrupters or vacuum bottles,
where the air has been evacuated. Arc quenchers
are not required because any arc formed between
opening contacts is not sustained due to the
presence of the vacuum. The arc is extinguished
when the current crosses zero after the contacts
are opened, therefore the arc typically does not
survive more than one half cycle. There is one
vacuum interrupter or bottle per pole, therefore a
three pole contactor has three vacuum
interrupters or bottles. The power contacts are not
affected by ambient conditions or contamination.
This provides for long life and reliable operation in
harsh applications.
Altitude
The reversing vacuum contactor is designed to
tolerate normal barometric pressure variances up
to 6600 feet above sea level. If the contactor is to
be used above 6600 feet above sea level, please
consult the factory.
Termination Means
The Size 4 reversing vacuum contactor is
supplied with line and load side lugs. The Size 5
and 6 reversing vacuum contactors are supplied
without line and load side lugs. Class 9999 Type
LUW5 and LUW6 lug kits are available for the Size
5 and 6 contactors. These kits include six lugs and
the necessary mounting hardware.
Auxiliary Contacts
An auxiliary contact block, Class 9999 Type
WX11, with one normally-open contact and
normally-closed contact is used with Size 4, 5 and
6 vacuum contactors.
Class 8702 – Full Voltage Reversing Vacuum Contactors (Horizontal Only)
3-Pole Polyphase – 600 Volts AC Maximum (50-60 Hertz)
NEMA Size
4
5
6
Enclosed
Ampere Rating
135
270
540
Locked Rotor
Motor Volts
Current (Amps)
Open Type
Max. HP
t Coil Voltage
1080
200
230
380
460
575
40
50
75
100
100
120
240
120
480
600
WFO3V02S
WFO3V03
WFO3V02S
WFO3V06
WFO3V07
2160
200
230
380
460
575
75
100
150
200
200
120
240
120
480
600
WGO3V02S
WGO3V03
WGO3V02S
WGO3V06
WGO3V07
4320
200
230
380
460
575
150
200
300
400
400
120
240
120
480
600
WHO3V02S
WHO3V03
WHO3V02S
WHO3V06
WHO3V07
Type
File E78351
CCN NLDX2
File LR60905
Class 3211-04
37
5/98
© 1998 Square D All Rights Reserved
Full Voltage Contactors — NEMA
Selection – Class 8702
Class 9998 – Replacement Coils for Class 8502 and 8702 Vacuum Contactors
Size
Type
4
5
6
Poles
WF
WG
WH
Hertz
Suffix Number (Complete Coil Number Consists of Class and Type
Followed by Suffix Number)
50
60
120 Volts
110 Volts
240 Volts
220 Volts
480 Volts
440 Volts
600 Volts
550 Volts
120
240
480
600
Class & Type
9998WF
9998WG
9998WH
All
Class 9999 – Vacuum Contactor Kits
For Use With
Kit Description
Class 9999
Type
Auxiliary Contacts, Non-Convertible
1-N.O. & 1-N.C. Isolated Contacts
9999WX11
Type
Size
WF-WH
4-6
WF
WG-WH
4
5-6
Coil Circuit Auxiliary Contacts
1-N.O. & 1-N.C. Isolated Contacts, Delayed Break
1-N.C. Isolated Contact
9999WCX11
9999WLX01
WG
WH
5
6
Lug Kits
(6) lugs included
(6) lugs included
9999LUW5
9999LUW6
Auxiliary Contact Ratings — NEMA A600, R300
.44
4.88
.28 Dia.
3.50
11
7
(3) Mtg. Holes
89
Description
Voltage
Make
Break
Class 9999
Type WX11 and
WXO1
120-600 Vac
72-120 Vac
28-72 Vac
28-300 Vac
7200 VA
60 A
60 A
28 A
720 VA
720 VA
10 A
28 VA
Mechanical
Overtravel
Interlock
Gauge
124
8.80
6.00
7.00
175
37
Rear View
Drilling Plan
6.45
1.13
1.44
178
Recess for
Auxiliary
Contact
107
6.88
224
Max.
152
4.20
164
29
9.75
Side View
248
Front View
Class 8702 WF
22.00
559
5.81
148
.60
4.00 2.50 3.65
102
64
93
51
2.70
.86
112
165
3.40 3.90
70
45
1
2
3
4
5
6
14.00
.38
356
10
417
127
457
14.00
1.50
38
Name
Plate
95
16.40
5.00
18.00
0
1
2
38
3.75
99
86
7
8
9
1.50
6.50
175
2.75
1.76
2.70
69
69
6.90
22
15
4.40
2.00
7.75
2.48
3.98
197
63
24.00
610
108
.40
64
10
3.75
2.70
9.56
69
243
559
1.89
2.70
4.40
112
22.00
48
24.00
69
1.40
2.00
51
7.75
197
36
610
Size 6 Reversing Contactor Outline without Lugs
Size 5 Reversing Contactor Outline without Lugs
Class 8702 WG
457
95
101
4.26 2.50
18.00
356
Name
Plate
Class 8702 WH
38
© 1998 Square D All Rights Reserved
5/98
Contents
SECTION 3 – MOTOR STARTERS MULTI-SPEED
Application Data – Class 8810, 8811, 8812 . . . . . . . . . . . . . . . . . . . . . 40-41
Line Voltage — with Melting Alloy Overload Relays – Class 8810. . . . . . . 42
Reversing Line Voltage Type — with Melting Alloy Overload Relays –
Class 8810 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Line Voltage — with Melting Alloy Overload Relays or
Solid State Overload Relays – Class 8810. . . . . . . . . . . . . . . . . . . 44-45
Line Voltage — with Melting Alloy Overload Relays – Class 8811, 8812. . 48
Application Data – Class 8810, 8811, 8812 . . . . . . . . . . . . . . . . . . . . . . . . 47
Application Data for Types SB-SJ – Class 8810, 8811, 8812 . . . . . . . . . . 48
Dimensions – Class 8810, 8811, 8812 . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Application Data – Class 8810, 8811, 8812 . . . . . . . . . . . . . . . . . . . . . 50-51
Disconnect Switch or Circuit Breaker Type – Class 8810, 8811, 8812 . . . 52
39
5/98
© 1998 Square D All Rights Reserved
AC Multispeed Magnetic Starters
Application Data – Class 8810, 8811, 8812
Typical Schematic Diagrams
High 4 Low 5 H
1 Stop
Multispeed motors are available in two basic versions:
L
OL OL
L
High
3 L
2
H
H
L1
L2
L3
L
L
L
H
OL OL OL
H
L
T1
T2
H
OL OL
T3
OL
Separate winding motors are usually chosen when flexibility is important,
since the speeds of a consequent pole motor are usually limited to a 2/1 ratio;
a broad range of speeds can be obtained on a separate winding motor.
L
T6
T4
T5
Both consequent pole and separate winding motors are available in three types:
A30064-446
2-Speed Consequent Pole Constant Horsepower
NEMA Size 0-4
Sizes 5, 6 & 7 Use Special Circuitry
High 4 Low 5 H
1 Stop
L
OL OL
L
High
3 L
2
• Consequent pole
• Separate winding
A separate winding motor has a winding for each speed while a consequent
pole motor has a winding for every two speeds (three speed motors have two
windings). The motor connections (and thus the types of controllers) for two
speed starters are exemplified by the schematic diagrams shown to the left.
Note that consequent pole two speed controllers involve a 5-pole and a
3-pole starter while separate winding controllers have two 3-pole starters.
• Constant horsepower
• Constant torque
• Variable torque
Typical applications for these different types of motors are shown below.
NOTE: For detailed information involving the technical aspects of flexibility of
the starters used in the multispeed controllers, see Classes 8702, 8736 and
8810 application data.
H
H
L1
L2
L3
Typical Applications
L
L
H
L
OL OL OL
H
T1
H
H
OL OL
OL
Constant H.P.
H
T2
T3
T6
T4
• Spindles
• Cutting Tools
T5
— Lathes
— Saws
2-Speed Consequent Pole Constant or Variable Torque
NEMA Size 0-4
Sizes 5, 6 & 7 Use Special Circuitry
High 4
1 Stop
Low
5 H
L
High
3 L
H
OL OL
•
•
•
•
L
2
H
L1
L2
L3
L
L
L
H
OL OL OL
T1
T2
T3
H
OL OL
Constant Torque
H
Conveyors
Mills
Dough Mixers
Reciprocating Pumps
Variable Torque
OL
T11 T12 T13
•
•
Fans
Centrifugal Pumps
A30064-442
2-Speed Separate Winding Constant HP, Constant Torque
and Variable Torque NEMA Size 0-4
Sizes 5, 6 & 7 Use Special Circuitry
Speed Selection
The speed of a squirrel cage motor is directly proportional to the power
supply frequency and inversely proportional to the number of poles in the
stator winding. With the frequency constant, motor speed is determined by
the number of poles.
(120) (Frequency)
(RPM) Speed =
No. of Poles
Horsepower =
T x S Where:
T = Torque in Lb Ft
5250 S = Speed in RPM
40
© 1998 Square D All Rights Reserved
5/98
AC Multispeed Magnetic Starters
Application Data – Class 8810, 8811, 8812
ADDITIONAL FEATURES
Special Pilot Lighting
High 4 Low 5 H
1 Stop
L
OL OL
L
2
L
High
3 L
H
H
General
On
Standard starters are not equipped with any special relays to require starting
at lowest speed, progressive acceleration or deceleration through each
speed, etc. However, when the type of motor or characteristics of the load
involved make certain starting or control sequences necessary, four types of
relays/timers are available to accomplish the required function.
H
To Power Circuit
A30080-017
One pilot light “ON”
High 4
1 Stop
Low
5 H
L
High
3 L
H
OLOL
Form R1 Compelling Relay
L
2
This relay makes it necessary for the motor to be started at low speed before
any higher speed can be selected. Pressing any push button except the low
speed will not start the motor. This arrangement insures that the motor will
always start the load at low speed. The stop button must be pressed before
it is possible to change from a higher to a lower speed.
H
L
Special Relays for Non-Reversing and Reversing Multispeed Starters
Off
H
To Power Circuit
A30080-018
One pilot light “OFF”
Form R2 Accelerating Relay/Timer
L
High 4
1 Stop
2
Low
5 H
L
L
H
High
3 L
H
OLOL
H
To Power Circuit
When the starter is equipped with Form R2 accelerating relays, the ultimate
speed is determined by the button which is pressed, but the starter will start
the motor at low speed and then automatically accelerate it through
successive steps until the selected speed is reached. Definite time intervals
must elapse between each speed change. Individual timing relays are
provided for each interval, and all are adjustable. The stop button must be
pressed before it is possible to change from a higher to a lower speed.
A30080-015
Two pilot lights “L” and “H”
High 4
1 Stop
Low
Form R3 Decelerating Relay/Timer
5 H
L
High
3 L
H
OLOL
L
2
L
H
H
L
On
Off
H
This is similar in action to Form R2 accelerating relays, except that they
function to prevent immediate transfer from a higher to a lower speed. A
definite time interval, preset on the timer, must elapse between each speed
change.
Form R10 Antiplugging Relays/Timers
To Power Circuit
A30080-016
Two pilot lights “ON” and “OFF”
L
1 Stop
High 4
2
Low
5 H
L
L
H
High
3 L
H
OLOL
If it is necessary to have an imposed time delay when transferring from the
forward to the reverse direction or reverse to forward, then Form R10 should
be included in the form designation of the reversing multispeed starters.
This provides up to a 60 second delay in the transfer of the direction of the
motor, and can help prevent damage which could result from plugging.
H
L
H
Off
To Power Circuit
A30080-019
Three pilot lights “L”, “H” and “OFF”
41
5/98
© 1998 Square D All Rights Reserved
AC Two Speed Magnetic Starters
Line Voltage — with Melting Alloy Overload Relays – Class 8810
Line voltage type, ac two speed starters are designed to control reconnectable squirrel cage motors to
operate at two different constant speeds, depending upon their construction. The use of an automatic
starter and proper control station permits greater operating efficiency and offers protection to both motor
and machine against improper sequencing or too rapid speed change. Protection against motor
overload in each speed is provided by an overload relay block which accepts three (3) thermal units.
Class 8810 Non-reversing – Two Speed – 50-60 Hertz – 600 Volts Maximum
Class 8810, Type S
in NEMA Type 1 Enclosure
Maximum Polyphase Horsepower
Ratings
Type
of
Motor
General
Purpose
Constant Torque Enclosure
or Variable
NEMA
Torque Motors
Type 1
Constant
NEMA
Horsepower
Size
Motors
200 V 230 V
460460Type
200 V 230 V
575 V
575 V
Watertight and
Dusttight
Enclosure
(Stainless Steel)
(Sizes 0-5 only)
Size 6 Sheet Steelc
NEMA Type 4
For Hazardous
Locations Class I
Groups C & D
Class II
Groups E, F & G
NEMA Types
7 and 9 k
Dusttight and
Driptight
Open
Industrial Use
Type
Enclosure
NEMA Type 12j
Type
Type
Type
Type
Single Winding (Consequent Pole) 5-Pole – 3-Pole
0
2
2
3
...
...
...
SBG-1
SBW-1q
...
SBA-1q
SBO-1
...
...
...
SCG-1
SCW-1q
SCR-1k
SCA-1q
SCO-1
1
5
5
71⁄2
71⁄2
10
20
...
...
...
SDG-1
SDW-1
SDR-1k
SDA-1
SDO-1
Constant 2
3
20
25
40
...
...
...
SEG-1
SEW-1
SER-1k
SEA-1
SEO-1
HP
4
30
40
75
...
...
...
SFG-1
SFW-1
...
SFA-1
SFO-1
5
60
75
150
...
...
...
SGG-1
SGW-1
...
SGA-1
SGO-1
6
100
150
300
...
...
...
SHG-1
SHW-1
...
SHA-1
SHO-1
0
...
...
...
3
3
5
SBG-2
SBW-2q
...
SBA-2q
SBO-2
Constant 1
71⁄2
10
SCG-2
SCW-2q
SCR-2k
SCA-2q
SCO-2
...
...
...
71⁄2
Torque 2
...
...
...
10
15
25
SDG-2
SDW-2
SDR-2k
SDA-2
SDO-2
or
3
...
...
...
25
30
50
SEG-2
SEW-2
SER-2k
SEA-2
SEO-2
...
...
...
40
50
100
SFG-2
SFW-2
...
SFA-2
SFO-2
Variable 4
5
.
.
.
.
.
.
.
.
.
75
100
200
SGG-2
SGW-2
.
.
.
SGA-2
SGO-2
Torque
6
...
...
...
150
200
400
SHG-2
SHW-2
...
SHA-2
SHO-2
Two Winding (Separate WInding) 3-Pole – 3-Pole f
0
2
2
3
...
...
...
SBG-3
SBW-3q
...
SBA-3q
SBO-3
...
...
...
SCG-3
SCW-3q
SCR-3k
SCA-3q
SCO-3
1
5
5
71⁄2
10
20
...
...
...
SDG-3
SDW-3
SDR-3k
SDA-3
SDO-3
2
71⁄2
Constant 3
20
25
40
...
...
...
SEG-3
SEW-3
SER-3k
SEA-3
SEO-3
4
30
40
75
...
...
...
SFG-3
SFW-3
...
SFA-3
SFO-3
HP f
5
60
75
150
...
...
...
SGG-3
SGW-3
...
SGA-3
SGO-3
6
100
150
300
...
...
...
SHG-3
SHW-3
...
SHA-3
SHO-3
7
...
225
450
...
...
...
SJG-3
...
...
SJA-3
SJO-3
0
...
...
...
3
3
5
SBG-4
SBW-4q
...
SBA-4q
SBO-4
71⁄2
10
SCG-4
SCW-4q
SCR-4k
SCA-4q
SCO-4
...
...
...
71⁄2
Constant 1
2
.
.
.
.
.
.
.
.
.
10
15
25
SDG-4
SDW-4
SDR-4k
SDA-4
SDO-4
Torque
3
...
...
...
25
30
50
SEG-4
SEW-4
SER-4k
SEA-4
SEO-4
or
4
...
...
...
40
50
100
SFG-4
SFW-4
...
SFA-4
SFO-4
Variable 5
...
...
...
75
100
200
SGG-4
SGW-4
...
SGA-4
SGO-4
Torque f 6
...
...
...
150
200
400
SHG-4
SHW-4
...
SHA-4
SHO-4
7
...
...
...
...
300
600
SJG-4
...
...
SJA-4
SJO-4
f
Type numbers shown for three phase separate winding motor starters apply only when motor windings are wye connected. When motor windings are
connected open delta use three phase consequent pole motor starters.
q
Separate NEMA Type 4 and 12 enclosures available.
j
NEMA Type 12 enclosures may be field modified for outdoor applications.
c
NEMA Type 4X enclosures available; consult local Square D field office.
k
Addition of forms to standard NEMA Type 7 and 9 enclosed devices is limited. Consult local Square D field office.
380 Volts, 50 Hertz – above type numbers will
apply to starters for 380 volt, 50 hertz but the
selection by NEMA size must be based on the
horsepower ratings in the following table:
NEMA Size
0
1
2
3
4
5
6
Constant Horsepower
3
71⁄2
20
40
60
100
200
Constant or Variable
Torque Horsepower
5
10
25
50
75
150
300
Thermal Units
File E78351
CCN NLDX
File LR60905
Class 3211-04
Thermal units should be ordered separately. See
Thermal Unit Selection Index. Do not use
horsepower rating(s) for thermal unit
selection. All three phase two speed magnetic
starters require six (6) thermal units, three per
speed. Use nameplate FLC’s (Full Load
Currents) from motor nameplate.
Special Features — See Factory Modifications
and Forms, Catalog 9999CT9701.
Dimensions — See Pages 49-52.
Field Modification Kits — See Catalog
9999CT9701 Section.
Class 8810, 8811 and 8812 multispeed starters,
both non-reversing and reversing versions, are
available with either circuit breaker or disconnect
switch. Refer to Factory Modifications and Forms
for Form numbers and price additions.
How to Order:
To Order Specify:
• Class Number
• Type Number
• Coil Voltage Code
• Form(s)
Catalog Number
Class
Type
Coil
Voltage
Code
Form(s)
8810
SCO8
VO6
P1S
42
© 1998 Square D All Rights Reserved
5/98
AC Reversing Two Speed Magnetic Starters
Line Voltage Type — with Melting Alloy Overload Relays – Class 8810
Class 8810 AC reversing two speed starters combine the functions of reversing and speed selection in one controller. The units
are electrically and mechanically interlocked, and include motor running overcurrent protection. Typical applications include
conveyors, drilling and tapping machines, and cooling tower fans. Many of these applications also require the special relay features.
Class 8810 – Reversing – 50-60 Hertz – 600 Volts Maximum
Maximum Polyphase Ratings
Type
of Motor
Reversing In One Speed Only
Dusttight and
General
Driptight Industrial
Constant
Constant Torque
Open
Purpose
NEMA
Use Enclosure
Horsepower
or Variable
Type
Enclosure
Size
NEMA Type 12
Motors
Torque Motors
NEMA Type 1
(Type 3 and 3R)f
200 V 230 V 460-575 V 200 V 230 V 460-575 V Typea
Typea
Typea
Reversing In Both Speeds
Dusttight and
General
Driptight Industrial
Open
Purpose
Use Enclosure
Type
Enclosure
NEMA Type 12
NEMA Type 1
(Type 3 and 3R)f
Type
Type
Type
Single Winding
Constant
Horsepower
0
1
2
3
4
5
2
5
71⁄2
20
30
60
2
5
10
25
40
75
3
71⁄2
20
40
75
150
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
SBG-21
SCG-21
SDG-21
SEG-21
SFG-21
SGG-21
SBA-21
SCA-21
SDA-21
SEA-21
SFA-21
SGA-21
SBO-21
SCO-21
SDO-21
SEO-21
SFO-21
SGO-21
SBG-31
SCG-31
SDG-31
SEG-31
SFG-31
SGG-31
SBA-31
SCA-31
SDA-31
SEA-31
SFA-31
SGA-31
SBO-31
SCO-31
SDO-31
SEO-31
SFO-31
SGO-31
Single
Winding
Constant
Torque or
Variable Torque
0
1
2
3
4
5
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
3
71⁄2
10
25
40
75
3
71⁄2
15
30
50
100
5
10
25
50
100
200
SBG-22
SCG-22
SDG-22
SEG-22
SFG-22
SGG-22
SBA-22
SCA-22
SDA-22
SEA-22
SFA-22
SGA-22
SBO-22
SCO-22
SDO-22
SEO-22
SFO-22
SGO-22
SBG-32
SCG-32
SDG-32
SEG-32
SFG-32
SGG-32
SBA-32
SCA-32
SDA-32
SEA-32
SFA-32
SGA-32
SBO-32
SCO-32
SDO-32
SEO-32
SFO-32
SGO-32
Constantj
Horsepower
0
1
2
3
4
5
2
5
71⁄2
20
30
60
2
5
10
25
40
75
3
71⁄2
20
40
75
150
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
SBG-23
SCG-23
SDG-23
SEG-23
SFG-23
SGG-23
SBA-23
SCA-23
SDA-23
SEA-23
SFA-23
SGA-23
SBO-23
SCO-23
SDO-23
SEO-23
SFO-23
SGO-23
SBG-33
SCG-33
SDG-33
SEG-33
SFG-33
SGG-33
SBA-33
SCA-33
SDA-33
SEA-33
SFA-33
SGA-33
SBO-33
SCO-33
SDO-33
SEO-33
SFO-33
SGO-33
Constantj
Torque or
Variable Torque
0
1
2
3
4
5
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
3
71⁄2
10
25
40
75
3
71⁄2
15
30
50
100
5
10
25
50
100
200
SBG-24
SCG-24
SDG-24
SEG-24
SFG-24
SGG-24
SBA-24
SCA-24
SDA-24
SEA-24
SFA-24
SGA-24
SBO-24
SCO-24
SDO-24
SEO-24
SFO-24
SGO-24
SBG-34
SCG-34
SDG-34
SEG-34
SFG-34
SGG-34
SBA-34
SCA-34
SDA-34
SEA-34
SFA-34
SGA-34
SBO-34
SCO-34
SDO-34
SEO-34
SFO-34
SGO-34
j
q
f
Prices and Type numbers shown for three phase, separate winding motor starters apply only when motor windings are wye connected. When motor windings are connected open delta use
the prices shown for consequent pole motor starters.
Specify the speed which requires reversing by adding an L (low) or an H (high) after the type number, e.g. A Class 8810 Type SBG-21 with reversing in low only would be ordered as a Class
8810 Type SBG-21L.
NEMA Type 12 enclosures may be field modified for outdoor applications. For details refer to Class 9991.
Typical Elementray Diagrams
5
2
3
4
3
2
High
L1
1
L3
L2
High 4 Low 5
L
1 Stop
5
4
High
Low
High
3
2
Low
H
L
L
H
OL
H
Stop
1
L1
3 Wire
Control
COM
OL
L2
L3
Alarm
(If supplied)
T12 T1 T3
T11 T13 T2
T11
1.2 or 3 OLR
Contacts
Motor
T12
Speed
Low
High
T13
T2
L1 L2 L3 Open
T1 T2 T3 T11, T12, T13
T11 T12 T13 T1, T2, T3
How to Order:
L
L
T3
1.2 or 3 OLR
Contacts
T1
T2
T3
H
H
OL OL
H
OL
T11 T12 T13
Thermal Units
To Order Specify:
• Class Number
• Type Number
• Coil Voltage Code
• Form(s)
T1
L
OL OL OL
OL
COM
Catalog Number
Class
Type
Coil
Voltage
Code
Form(s)
8810
SCO8
VO6
P1S
Thermal units should be ordered separately. See Thermal Unit
Selection Index. Do not use horsepower rating(s) for
thermal unit selection. All three phase two speed magnetic
starters require six (6) thermal units, three per speed. Use
nameplate FLC’s (Full Load Currents) from motor nameplate.
43
5/98
© 1998 Square D All Rights Reserved
AC Two Speed Magnetic Starters
Line Voltage — with Melting Alloy Overload Relays or Solid State Overload Relays – Class 8810
Class 8810 — Non-Reversing — Horizontally Arranged Starters
q j Glass Polyester Watertight, Dusttight and Corrosion Resistant Enclosure
50-60 Hertz – 600 Volts Maximum
For Consequent
Pole Motors
Maximum Horsepower Ratings
For Separate
Winding Motors
Type of
Motor
NEMA
Size
200 V
230 V
380 V
460-575 V
Type
Type
Constant
Horsepower
0
1
2
3
4
2
5
71⁄2
20
30
2
5
10
25
40
3
71⁄2
20
40
60
3
71⁄2
20
40
75
SBW-51
SCW-51
SDW-51
SEW-51
...
SBW-53
SCW-53
SDW-53
SEW-53
SFW-53
Constant
Torque or
Variable
Torque
0
1
2
3
4
3
71⁄2
10
25
40
3
71⁄2
15
30
50
5
10
25
50
75
5
10
25
50
100
SBW-52
SCW-52
SDW-52
SEW-52
...
SBW-54
SCW-54
SDW-54
SEW-54
SFW-54
q
j
NEMA Type 4X hubs are included with each starter at no additional cost.
Combination features available – consult factory.
Vertically Arranged, Open Type, Two Speed Starters
Vertically arranged starters are used where width limitations prevent the use of the conventional
horizontally arranged device. Such starters may be used to advantage in threaded NEMA Type 7
explosion-proof enclosures, and in multi-motor panels in which other equipment within the enclosure
used limits the available width.
These starters have all the features of the standard horizontally arranged devices, but the two
contactors are in a vertical arrangement. These starters are offered in open type construction only.
Class 8810 — Non-Reversing — Vertically Arranged Starters – 50 or 60 Hertz – 600 Volts Maximum
For Consequent
Pole Motors
Maximum Horsepower Ratings
For Separate
Winding Motors
Type of
Motor
NEMA
Size
200 V
230 V
380 V
460-575 V
Type
Type
Constant
Horsepower
0
1
2
3
4
2
5
71⁄2
20
30
2
5
10
25
40
3
71⁄2
20
40
60
3
71⁄2
20
40
75
SBO-11
SCO-11
SDO-11
SEO-11
SFO-11
SBO-13
SCO-13
SDO-13
SEO-13
SFO-13
Constant
Torque or
Variable
Torque
0
1
2
3
4
3
71⁄2
10
25
40
3
71⁄2
15
30
50
5
10
25
50
75
5
10
25
50
100
SBO-12
SCO-12
SDO-12
SEO-12
SFO-12
SBO-14
SCO-14
SDO-14
SEO-14
SFO-14
How to Order:
To Order Specify:
• Class Number
• Type Number
• Coil Voltage Code
• Form(s)
Catalog Number
Class
Type
Coil
Voltage
Code
Form(s)
8810
SCO8
VO6
P1S
Thermal Units
Thermal units should be ordered separately. For selection of thermal units, refer to the Catalog Thermal
Unit Selection Index, Digest or Bulletin SM-416, entitled “Application and Selection of Overload Relays.”
Do not use horsepower rating(s) for thermal unit selection. All three phase two speed magnetic starters
require six (6) thermal units, three per speed. Use nameplate FLC’s (Full Load Currents) from motor
nameplate.
44
© 1998 Square D All Rights Reserved
5/98
AC Two Speed Magnetic Starters
Line Voltage — with Melting Alloy Overload Relays or Solid State Overload Relays – Class 8810
Special Arrangements with Three Devices
Three Type S Contactors can be mechanically
interlocked so that only one contactor can be
energized at any one time. The mechanical
interlock, pictured in Figure 2, is an interference
(non-jamming) type locking at the beginning of the
stroke of any contactor.
Factory assembled units are listed in the table
below. Figures 1 and 2 show factory assembled
and wired devices. All contactors are both
electrically and mechanically interlocked. The
class and type numbers listed only cover the
contactor and/or starter mounting arrangement,
NEMA size of the devices, and the number of
poles. A power and control wiring diagram must
accompany each order. Additional electrical
interlocks are available factory (or field) installed
in the locations shown in Figure No. 2 and Table
No. 2, Page 52. 8810 starters are supplied with
melting alloy type thermal overload relays.
For customer assembled units, the basic
A
C
E
G
J
L
No.
No.
No.
mechanical interlock and base assembly can be
OL-35
1
2
3
purchased separately. Standard Class 8502
Cont.
Cont.
Cont.
B
D
F
H
K
M
contactors and Class 8536 starters are used in
the locations and pole arrangement shown. If
Class 8536 starters are used, it is necessary to
OL-1
OL-2
OL-3
mount a Class 9999 Type SO bracket below the
overload block to give the block support.
Figure 2
For electrically interlocking customer assembled
Contactor, overload and external electrical
units a Class 9999 Type SX-12, normally closed
interlock positions
internal interlock and/or a Class 9999 Type SX-7,
normally closed external interlock can be used.
Three Mechanically Interlocked Contactors and Starters — Factory Assembled
Class Type
8810
8810
SCO-41
SCO-42
SCO-43
SCO-44
SDO-41
SDO-42
SCO-45
SCO-46
SCO-47
SCO-48
SDO-43
SDO-44
Contactor Position — See Figure 2
No. 1 Contactor
No. 2 Contactor
Size and Poles
Size and Poles
NEMA Size 1 NEMA Size 2 NEMA Size 1 NEMA Size 2
No. of Poles No. of Poles No. of Poles No. of Poles
Overload
No. 3 Contactor
Relay
Size and Poles
Position
NEMA Size 1 NEMA Size 2
See Fig. 3
No. of Poles No. of Poles
3
4
...
...
...
...
3
4
...
...
...
...
3
3
3
3
...
...
5
5
5
5
...
...
...
...
3
4
3
4
...
...
3
4
3
4
3
3
3
3
...
...
3
3
3
3
...
...
...
...
...
...
3
3
...
...
...
...
3
3
Ordering Information Required
1. Order complete factory assembled devices by
class and type number from table above.
2. Supply wiring diagram for power and control
connections as catalog number only covers
general contactor and starter mounting
arrangement.
3. Voltage and frequency of contactor coils.
4. Select additional factory assembled electrical
interlocks from table on Page 47 specifying
interlock position letter and whether interlock
is N.O. or N.C.
5. Example of ordering information required on
factory assembled devices:
(a) Class 8810 Type SCO-45
...
...
...
...
3
3
...
...
...
...
5
5
Number of
Thermal
Units
Required
OL-2 & -3
6
OL-2 & -3
6
(b) Wired per diagram
(which must accompany order)
(c) All coils — 120 volts, 60 hertz
(d) Additional electrical interlocks:
C — N.O., E — N.C., and J — N.O.
6. For customer assembly of three mechanically
interlocked devices, order the mechanical
interlock and overload relay mounting
brackets by class and type numbers.
Thermal Units
Thermal units should be ordered separately. For
selection of thermal units, refer to the Catalog
Thermal Unit Selection Index R Digest. Use the
motor nameplate FLC’s (Full Load Currents) to
select thermal units.
45
5/98
© 1998 Square D All Rights Reserved
Three and Four Speed AC Magnetic Starters
Line Voltage — with Melting Alloy Overload Relays – Class 8811, 8812
Class 881 and 8812 line voltage starters are designed to control 3 and 4 speed motors, respectively.
The use of an automatic starter and proper control station permits greater efficiency. The addition of
compelling relays to a starter gives protection to both the motor and the machine against an improper
sequence or a too rapid change in speed. The motor is protected against excessive operating currents
by overload relay blocks (one for each motor speed) each of which accepts three (3) thermal units. While
the starters listed are for use with consequent pole motors only, separate winding motor starters are
also available upon request.
Class 8811 — Three Speed AC Magnetic Starters — Consequent Pole, 2 Winding
600 Volts Maximum — 50-60 Hertz
Type of
Motor
200 V 230 V 460-575 V Type
Watertight and
Dusttight Enclosure
(Stainless Steel)
NEMA Type 4
Type
Dusttight and Driptight
Industrial Use Enclosure
NEMA Type 12
(Type 3 and 3R)j
Type
2
5
71⁄2
20
30
3
71⁄2
10
25
40
3
71⁄2
10
25
40
SBW-1
SCW-1
SDW-1
SEW-1
SFW-1
SBW-2
SCW-2
SDW-2
SEW-2
SFW-2
SBW-3
SCW-3
SDW-3
SEW-3
SFW-3
SBA-1
SCA-1
SDA-1
SEA-1
SFA-1
SBA-2
SCA-2
SDA-2
SEA-2
SFA-2
SBA-3
SCA-3
SDA-3
SEA-3
SFA-3
General Purpose
NEMA Maximum Horsepower Enclosure
NEMA Type 1
Size
0
1
Constant
2
Horsepower
3
4
0
1
Constant
2
Torque
3
4
0
1
Variable
2
Torque
3
4
2
5
10
25
40
3
71⁄2
15
30
50
3
71⁄2
15
30
50
3
71⁄2
20
40
75
5
10
25
50
100
5
10
25
50
100
SBG-1
SCG-1
SDG-1
SEG-1
SFG-1
SBG-2
SCG-2
SDG-2
SEG-2
SFG-2
SBG-3
SCG-3
SDG-3
SEG-3
SFG-3
Open
Type
Type
SBO-1
SCO-1
SDO-1
SEO-1
SFO-1
SBO-2
SCO-2
SDO-2
SEO-2
SFO-2
SBO-3
SCO-3
SDO-3
SEO-3
SFO-3
Class 8812 — Four Speed AC Magnetic Starters — Consequent Pole, 2 Winding
600 Volts Maximum — 50-60 Hertz
Type of
Motor
General Purpose
NEMA Maximum Horsepower Enclosure
NEMA Type 1
Size
200 V 230 V 460-575 V Type
Watertight and
Dusttight Enclosure
(Stainless Steel)
NEMA Type 4
Type
0
2
2
3
SBG-1
SBW-1
SCG-1
SCW-1
1
5
5
71⁄2
Constant
2
71⁄2
10
20
SDG-1
SDW-1
Horsepower
3
20
25
40
SEG-1
SEW-1
4
30
40
75
SFG-1
SFW-1
0
3
3
5
SBG-2
SBW-2
1
1
7 ⁄2
10
SCG-2
SCW-2
1
7 ⁄2
Constant
2
10
15
25
SDG-2
SDW-2
Torque
3
25
30
50
SEG-2
SEW-2
4
40
50
100
SFG-2
SFW-2
0
3
3
5
SBG-3
SBW-3
71⁄2
10
SCG-3
SCW-3
1
71⁄2
Variable
2
10
15
25
SDG-3
SDW-3
Torque
3
25
30
50
SEG-3
SEW-3
4
40
50
100
SFG-3
SFW-3
j
NEMA Type 12 enclosures may be field modified for outdoor applications.
Dusttight and Driptight
Industrial Use Enclosure
NEMA Type 12
(Type 3 and 3R)j
Type
SBA-1
SCA-1
SDA-1
SEA-1
SFA-1
SBA-2
SCA-2
SDA-2
SEA-2
SFA-2
SBA-3
SCA-3
SDA-3
SEA-3
SFA-3
Open
Type
Type
SBO-1
SCO-1
SDO-1
SEO-1
SFO-1
SBO-2
SCO-2
SDO-2
SEO-2
SFO-2
SBO-3
SCO-3
SDO-3
SEO-3
SFO-3
Thermal Units
Thermal units should be ordered separately. For selection of thermal units, refer to the Catalog Thermal
Unit Selection Index R Digest. All starters require the use of three (3) thermal units for each speed of
the motor. Do not use the horsepower rating(s) for selection. Use nameplate FLC’s (Full Load Currents)
from motor nameplate.
How to Order:
To Order Specify:
File E78351
CCN NLDX
• Class Number
• Type Number
• Coil Voltage Code
• Form(s)
Catalog Number
Class
Type
Coil
Voltage
Code
Form(s)
8810
SCO8
VO6
P1S
File LR60905
Class 3211-04
46
© 1998 Square D All Rights Reserved
5/98
AC Multispeed Magnetic Starters
Application Data – Class 8810, 8811, 8812
Application Data for Types SB-SH
Form Designations for Factory Installation of Electrical Interlocks
Additional Electrical Interlocks on High Starter
Standard
(No Additional
Interlocks)
Additional Electrical Interlocks
on Low Starter
Standard (No Additional
Interlocks)
Change N.O.
Holding Circuit
Interlock to N.C.
1 N.O.
1 N.C.
2 N.O.
1 N.O.-1 N.C.
2 N.C.
X01
X02
X03
X05
X06
X07
Change N.O. Holding
Circuit Interlock to N.C.
X10
X11
X12
X13
X15
X16
X17
1 N.O.
X20
X21
X22
X23
X25
X26
X27
1 N.C.
X30
X31
X32
X33
X35
X36
X37
2 N.O.
X50
X51
X52
X53
X55
X56
X57
1 N.O.-1 N.C.
X60
X61
X62
X63
X65
X66
X67
2 N.C.
X70
X71
X72
X73
X75
X76
X77
Control Transformer Selection
Maximum Number of Auxiliary Units
The following table gives the proper size control
transformer to be used with a given reversing
device, with or without additional electrical
interlocks or timer.
NEMA
Size
(Type)
NEMA
Size
Type
0, 1 & 2
SB, SC & SD
3
No. of Poles
Transformert
Class 9070 Type
Any
EO-2 or GO-2
3
EO-3 or GO-3
4&5
EO-4
SE
4
SF
Any
EO-4
5
SG
Any
q
6
SH
Any
u
7
SJ
Any
j
t
q
u
j
Maximum number of auxiliary units
No. of
on each contactor, forward or
Poles of
reverse, (in addition to internal
Basic
holding circuit and electrical
Contactor
interlocks).
00, 0, 1
2 or 3
and 2
(SA, SB, SC
and SD)
4
4 single circuit external interlocks (N.O. or N.C.)
1 single circuit external interlock (N.O. or N.C.)
plus 1 attached timer (ON or OFF delay).
2 single circuit external interlocks (N.O. or N.C.)
3, 4, 5 and 6
(SE, SF, SG Any
and SH)
2 single circuit external interlocks (N.O. or N.C.)
7 (SJ)
Consult local Square D field office
Any
1 single circuit external interlock plus 1
attached timer (ON or OFF delay).
If a different manufacturer’s transformer is to be used, check its
suitability for use with coil loads. See inrush and sealed VA ratings
of the contactor coil.
Standard engineering practice for Size 5 contactors is to use a
Class 9070 Type EO-1 transformer and Class 8501 Type DO-20
control relay.
A Class 9070 Type EO-3S2 transformer is an integral part of the
Size 6 control circuit providing 120 volt control circuit voltage as
standard on devices wired for common control.
A Class 9070 Type EO-19-S2 transformer is an integral part of the
size 7 control circuit providing 120 volt control circuit voltage as
standard on devices wired for common control.
AC Magnet Coils for AC Contactors and Starters
Devices Using
Coil
NEMA
Type Poles
Size
00
0
1
2
3
4
5
6
7
u
Coil
Specification
Number
Suffix Numbers (Complete coil part number consists of specification number followed by
suffix number as 31041-400-51.)
480 V/60 Hz 600 V/60 Hz
240 V/60 Hz
120 V/60 Hz
277 V/60 Hz
208 V/60 Hz 220 V/60 Hz
24 V/60 Hz
440 V/50 Hz 550 V/50 Hz
220 V/50 Hz
110 V/50 Hz
SA
SB
SC
All
31041-400- 20
42
48
All
31041-400- 20
42
48
All
31041-400- 20
42
48
3
31063-409- 16
38
44
SD
4-5
31063-400- 16
38
44
3
31074-400- 16
38
44
SE
4-5
31091-400- 16
38
44
SF
All
31091-400- 16
38
44
SG
3
31096-400- . . .
09
15
SH
3
31104-400-50 (all voltages)
SJ
3
31104-400-50 (all voltages)
For 220 volt and 230 volt, 60 hertz applications, use 240 volt coil.
u
u
u
u
u
u
u
u
u
51
51
51
47
47
47
47
47
18
52
52
52
49
49
49
49
49
19
60
60
60
57
57
57
57
57
24
62
62
62
60
60
60
60
60
29
47
5/98
© 1998 Square D All Rights Reserved
AC Multispeed Magnetic Starters
Application Data for Types SB-SJ – Class 8810, 8811, 8812
MECHANICAL INTERLOCK
General
Class 9999 Type SM-1
Mechanical Interlock For
Two Contactors
Horizontally Mounted
Type S contactors or starters can be mechanically
interlocked so that only one device will be
energized at a time. The mechanical interlock is
an interference (non-jamming) type, locking at the
beginning of the stroke of any starter or contactor.
Three unit mechanically interlocked contactors
and/or starters are also available for various
combinations of Sizes 0, 1 and 2.
Type S Sizes 3, 4, 5 and 6
Overload Relay Mounting Bracket
Mechanical interlock Types SM-1 through SM-10
for Sizes 00-2 devices use overload relay
mounting brackets to support the overload relay
portion of the starter.
Class 9999 Type SM-12
For Sizes 3 and 4
Horizontally Mounted
three pole contactors, a different version for four
or five pole contactors. When adding a power
pole to an existing three pole reversing
contactor, a new mechanical interlock must
also be installed.
Type S Sizes 00, 0, 1 and 2
The mechanical interlock is mounted on the
underside of the reversing baseplate. Two pins
extend from the mechanical interlock through
openings in the baseplate and engage the contact
carrier of each contactor. Two styles of
mechanical interlocks are used: one version for
The mechanical interlock is separate from the
mounting pan on Sizes 3-6. Cams on the
mechanical interlocks are operated by the contact
carrier of each contactor. The mechanical
interlock is attached to the underside of the two
contactors on Sizes 3 and 4; directly to the
mounting pan on sizes 5 and 6. Size 5 and 6
mechanical interlocks are sold only as a factory
assembly with the 8810 starter.
The mechanical interlock utilizes a special
baseplate and bracket that connects between the
armatures. This is sold only as a factory assembly
with the 8810 starter.
Mechanical Interlock for Two Contactors
Kit Description – The following kits consist of the mechanical interlock and base assembly for
interlocking 2-5 pole contactors. Mechanical interlocks for horizontal and vertical mounting are
listed for various pole arrangements.
4 Pole
or
5 Pole
2 Pole
or
3 Pole
2 Pole
or
3 Pole
Horizontal
Type SM-1 for Size 00j, 0, or 1
Type SM-6 for Size 2
Type SM-12 for Sizes 3 & 4
4 Pole
or
5 Pole
j
q
2 Pole
or
3 Pole
Horizontalt
Type SM-2 for Size 0 or 1
Type SM-7 for Size 2
Type SM-12 for Sizes 3 & 4
4 Pole
or
5 Pole
Horizontal
Type SM-3 for Size 0 or 1
Type SM-8 for Size 2
Type SM-12 for Sizes 3 & 4
t
4 Pole
or
5 Pole
00j, 0, 1
0, 1
0, 1
0, 1
0, 1
SM-1
SM-2t
SM-3
SM-4
SM-5
2
2
2
2
2
3
3, 4
4
SM-6
SM-7
SM-8
SM-9
SM-10
SM-11q
SM-12q
SM-13q
2 Pole
or
3 Pole
Verticalt
Type SM-2 for Size 0 or 1
Type SM-10 for Size 2
Type SM-11 for Size 3
Type SM-13 for Size 4
2 Pole
or
3 Pole
4 Pole
or
5 Pole
2 Pole
or
3 Pole
4 Pole
or
5 Pole
Vertical
Type SM-4 for Size 0 or 1
Type SM-9 for Size 2
Type SM-11 for Size 3
Type SM-13 for Size 4
Contactor Class
NEMA
9999
Size
Type
Horizontal
Type SM-5 for Size 0 or 1
Type SM-11 for Size 3
Type SM-13 for Size 4
The type SM-2 interlock is factory assembled for horizontal mounting but can easily be converted to vertical mounting. Conversion instructions are
included.
For replacement only on the NEMA Size 00, reversing starters and contactors.
Interlocks do not include mounting pan.
Overload Relay Mounting Bracket
Kit Description
Type SO-11 Overload Relay
Mounting Bracket
Class 9999 Type
Bracket for one overload relay used with horizontal mechanical interlocks, Types SM-1, SM-2, SM-3, SM-6, SM-7 and SM-8
SO-11
Bracket for two overload relays used with vertical mechanical interlocks, Types SM-2, SM-4, SM-5, SM-9 and SM-10
SO-12
48
© 1998 Square D All Rights Reserved
5/98
AC Two Speed Magnetic Starters
Dimensions – Class 8810, 8811, 8812
Non-Reversing — Open Type
Approximate Dimensions
.50
A
13
7.00
C
A
D
178
E
E
F
G
.50
C
13
B
D
I
H
RESET
B
RESET
RESET
P
.50 F
I
13
Provision for
(4) .31 Dia. Mounting Screws
8
H
Travel
M
J
L
K
G
N
K
RESET
J
Figure 1
Class 8810, Sizes 0, 1 & 2 Types SBO, SCO & SDO
.56
Reset
Travel
14
6.25
159
Figure 2
Class 8810, Sizes 3 & 4 Types SEO and SFO
A
G
F
C
E
A
F
E
G
C
B
I
I
B
D
D
H
M
M
K
J M
N
J
(4) L Dia.
Mounting Holes
M
M
H
Figure 3
Class 8810, Size 5 Type SGO
Fig. NEMA
Type
No. Size
0 and 1
1
2
3
2
4
3
5
Mtg. A
Holes IN
K
Figure 4
Class 8810, Size 6 Type SHO
B
C
D
mm IN
mm IN
mm IN
E
mm IN
G
H
mm IN
F
mm IN
mm IN
I
mm IN
J
N
(4) L Dia. Mounting Holes
K
mm IN
mm IN
L
mm IN
M
mm IN
N
mm IN
9.63 245 7.34 186 5.31 135 8.00 203 .63
16
...
...
.22
6
6.91 176 . . .
...
.22
6
4.75 121 2.25 57
5.06 129 .59
15
SBO-3, 4
3
SCO-3, 4
7.13 181 6.91 176 5.31 135 . . .
...
...
3.41 87
.47
12
6.22 158 . . .
...
.22
6
3.56 90
1.63 41
5.06 129 .59
15
SDO-1, 2 6
12.03 306 8.53 217 6.03 153 10.38 264 .50
13
...
.25
6
8.13 207 6.25 159 .16
4
5.75 146 2.81 71
5.16 131 .78
20
SDO-3, 4 3
9.00 229 8.06 205 6.03 153 . . .
...
4.50 114 .38
10
7.50 191 . . .
5
4.34 110 2.16 55
5.16 131 .78
20
SEO-1, 2 4
18.00 457 14.44 367 17.00 432 12.25 311 1.50 38
.69
18
.50
13
6.44 164 7.38 187 1.66 42
2.16 55
...
...
...
...
...
...
SEO-3, 4 4
12.75 324 12.28 312 11.75 298 10.75 273 1.03 26
.50
13
.50
13
2.50 64
6.75 171 1.16 29
1.16 29
...
...
...
...
...
...
SFO-1, 2 4
18.63 473 15.59 396 17.00 432 12.25 311 1.84 47
1.50 38
1.13 29
6.44 164 7.66 195 1.66 42
1.66 42
...
...
...
...
...
...
SFO-3, 4 4
14.25 362 14.59 371 13.25 337 12.25 311 1.84 47
.50
.50
13
2.94 75
1.66 42
...
...
...
...
...
...
SGO-1, 2t 4
29.28 744 20.28 515 9.38 238 5.41 137 1.28 33
28.00 711 .63
16
12.56 319 19.00 483 .63
15
22.53 572 .50
13
2.41 61
SGO-3, 4 4
19.28 490 20.28 515 9.38 238 5.14 137 1.28 33
18.00 457 .63
16
2.63 67
19.00 483 .63
15
12.53 318 .50
13
2.41 61
6.63 168
SHO-1, 2t 4
29.53 750 22.44 570 9.53 242 6.97 177 3.81 97
28.00 711 .75
19
11.63 295 21.19 538 .63
15
9.88 251 .56
14
3.03 77
9.31 236
SHO-3, 4 4
19.53 496 22.44 570 9.53 242 6.97 177 3.81 97
18.00 457 .75
19
1.69 43
15
9.88 251 .56
14
3.03 77
9.31 236
...
...
...
...
13
...
.19
7.38 187 1.66 42
6.63 168
4
6q
—
7f
t
Consequent pole, type starters consist of two 3-pole starters as pictured in Figure 3 and an additional 2-pole shorting contactor (not shown), all on a common base-plate, horizontally
mounted.
Current transformers used with Size 1 overload relay blocks.
Solid state overloads and special current transformers.
q
f
mm
SBO-1, 2
4
SCO-1, 2
SJO-3, 4
21.19 538 .63
Consult Square D
49
5/98
© 1998 Square D All Rights Reserved
AC Magnetic Starters
Application Data – Class 8810, 8811, 8812
Non-Reversing — Non-Combination — Enclosed
Approximate Dimensions
A
D
(4) H Dia.
Mounting Holes
E
G B
RESET
RESET
F
C
Figure 1
NEMA Type 1 Enclosure – Figure 1
A
B
C
D
E
F
G
H
Type
IN
mm
IN
mm
IN
mm
IN
mm
IN
mm
IN
mm
IN
mm
IN
mm
SBG and SCG
11.88 302
11.88 302
7.53
191
9.75
248
1.06
27
1.06
27
9.75
248
.31
8
SDG
14.88 378
14.13 359
7.66
195
12.75 324
1.06
27
1.06
27
12.00 305
.31
8
SEG-3 & -4 and SFG-3 & -4 18.16 461
29.16 741
9.23
234
15.50 394
1.34
34
1.34
34
26.50 673
.44
11
SEG-1 & -2 and SFG-1 & -2 22.16 563
39.16 995
10.23 260
19.50 495
1.34
34
1.34
34
36.50 927
.44
11
SGG-1, 2, 3, 4
20.22 514
65.75 1670
6.45
31.00 787
2.13
54
2.13
54
42.00 1067
.56
14
SHG-1, 2, 3, 4
36.22 920
62.22 1580
19.47 495
SJG-3 & 4
Consult Square D
G
H
164
Floor Mount
A
D
E
G B
RESET
RESET
C
F
(4) H Dia. Mounting Holes
Figure 2
NEMA Type 1 Enclosure – Figure 2
A
B
C
D
E
F
Type
IN
mm
IN
mm
IN
mm
IN
mm
IN
mm
IN
mm
IN
mm
IN
mm
SBA and SCA
11.88 302
13.50 343
7.75
197
4.25
108
3.81
97
.38
10
12.75 324
.31
8
SDA
14.88 378
15.75 400
7.88
200
4.25
108
5.31
135
.38
10
15.00 381
.31
8
SEA-3 & -4 and SFA-3 & -4 18.16 461
31.50 800
9.59
244
16.00 406
3.09
78
.50
13
30.50 775
.44
11
SEA-1 & -2 and SFA-1 & -2 22.16 563
41.50 1054
10.59 269
16.00 406
3.09
78
.50
13
40.50 1029
.44
11
SGA-1, 2, 3, 4
35.22 895
49.00 1245
13.11 333
27.00 686
4.11
104
.50
13
48.00 1219
.56
14
SHA-1, 2, 3, 4
36.22 920
62.22 1580
19.47 495
SJA-3 & 4
Consult Square D
Floor Mount
50
© 1998 Square D All Rights Reserved
5/98
AC Magnetic Starters
Application Data – Class 8810, 8811, 8812
Non-Reversing — Non-Combination — Enclosed
Approximate Dimensions
A
D
E
C
G B
RESET
RESET
J
I
F
(4) H Dia. Mounting Holes
Figure 3
NEMA Type 4 Enclosure – Figure 3
A
B
C
D
E
F
G
H
I
J
Type
IN
mm
IN
mm
IN
mm
IN
mm
IN
mm
IN
mm
IN
mm
IN
mm
IN
mm
IN
mm
SBW and SCW
12.63
321
14.69
373
7.81
198
4.25
108
4.19
106
.59
15
13.50
343
.31
8
1.66
42
2.31
59
SDW
14.88
378
15.75
400
8.25
210
4.25
108
5.31
135
.38
10
15.00
381
.31
8
2.03
52
2.63
67
SEW-3 & -4 and SFW-3 & -4
18.16
461
32.22
818
8.77
223
12.00
305
3.08
78
.86
22
30.50
775
.44
11
2.58
66
3.19
81
SEW-1 & -2 and SFW-1 & -2
22.16
563
42.22
1072
9.77
248
16.00
406
3.08
78
.86
22
40.50
1029
.44
11
2.33
59
2.89
73
SGW-1, 2, 3, 4
35.22
895
49.22
1250
12.13
308
27.00
686
4.09
104
.61
15
48.00
1219
.56
14
2.98
76
3.50
89
Top View
Rear View
Space Required
To Remove
Top Cover
N
E
Q
Rear Seal
R
A
(2) "L" Pipe
Tap Top and
Bottom
G
C
F
L
D
B
Threaded
Cover
Enclosure
Overload
Reset
H S
K
J
T
M
Mtg. Holes
and/or Slots (3)
Circuit Breaker
Operational Handle –
Combination Form Only
P
(Add 1.00 Inch To
Overall Width)
Space Required To
Remove Bottom Cover
Figure 4
NEMA Type 7 & 9 Enclosure – Figure 4
A
B
C
D
IN
mm IN
mm IN
mm IN
E
F
G
H
mm IN
mm IN
J
K
L
M
N
P
R
Type
mm IN
mm IN
mm IN
SCR-1, 2, 3 & 4
12.00 305 41.06 1043 68.06 1729 16.75 425 7.25 184 7.69 195 26.13 664 3.00 76
Std. & Form Y79-1
mm IN
mm IN
mm IN
mm IN
mm IN
mm IN mm
24.00 610
8.50
216 2.06 52
9.38
238 5.25 133 1.50 38
.38 10
SCR-1, 2, 3 & 4
12.00 305 46.13 1172 79.13 2010 16.75 425 12.25 311 7.69 195 26.13 664 9.00 229 24.00 610
Forms T & TY79-1
8.50
216 2.06 52
9.38
238 5.25 133 1.50 38
.38 10
SDR-1, 2, 3 & 4
16.13 410 48.50 1232 81.50 2070 20.25 514 12.50 318 8.63 219 27.75 705 8.00 203 25.00 635
Std. & Form Y79-1
12.00 305 2.63 67
11.00 279 5.50 140 2.50 64
.38 10
SCR-1, 2, 3 & 4
Forms T & Y79-1
12.00 305 2.63 67
11.00 279 5.50 140 2.50 64
.38 10
16.13 410 50.50 1283 85.00 2159 20.25 514 9.13 232 8.63 219 32.75 832 4.50 114 30.00 762
For Sizes 3, 4 and 5 consult Square D field office.
51
5/98
© 1998 Square D All Rights Reserved
AC Two Speed Combination Starters
Disconnect Switch or Circuit Breaker Type – Class 8810, 8811, 8812
“Quick Ship Only”
Approximate Dimensions
NEMA Type 1 Enclosure – Figure 1
Dimensions — Inches/mm
NEMA
Class Type
Size
A
B
C
D
E
Top & Bottom
Sides
F
G
H
I
J
K
L
M
N
O
P
W
X
Y
0-1
8810
SBG
SCG
13.88
353
23.13
588
8.25
210
10.63
270
21.00
533
19.28
490
1.88
48
1.88
48
3.75
95
2.31
59
1.06
27
3.30
84
2.19
56
1.25
32
.88
22
...
1⁄2-3⁄4-1
1⁄2-3⁄4-1
1⁄2
2
8810
SDG
15.16
385
28.91
734
9.56
243
11.63
295
26.25
667
21.81
554
2.19
56
2.00
51
4.00
102
2.63
67
1.33
34
3.30
84
2.22
56
1.27
32
.91
23
...
1-11⁄4
1⁄2-3⁄4
1⁄2
NEMA Type 4 Enclosure – Figure 2
Dimensions — Inches/mm
Top &
Bottom
Bottom
NEMA
Size
Class
Type
A
B
C
D
E
F
G
H
I
J
K
L
W
0-1
8810
SBW
SCW
13.88
353
8.33
212
25.19
640
3.30
84
2.56
65
8.75
222
24.00
610
.59
15
3.95
100
1.63
41
2.31
59
18.53
471
3⁄4
Hub
1 Hub
2
8810
SDW
15.13
389
9.58
243
30.94
786
3.30
84
2.56
65
10.00
254
29.75
756
.59
15
3.95
100
2.00
51
2.63
67
21.03
534
3⁄4
Hub
11⁄2 Hub
X
NEMA Type 12 Enclosure – Figure 3
Dimensions — Inches/mm
NEMA
Class Type A
B
C
Size
IN
mm IN
mm IN
0-1
8810
SBA
SCA
2
8810
SDA
A
E
F
G
H
I
J
IN
mm
IN
mm
IN
mm
IN
mm
IN
mm
IN
mm
IN
mm
13.88
353
10.09
256
24.75
629
3.30
84
2.56
65
8.75
222
24.00
610
.38
10
3.95
100
20.28
515
15.16
385
10.97
279
31.25
794
3.30
84
3.08
78
9.00
229
30.25
768
.50
13
4.83
123
23.44
595
Handle
Swing
L
M
D
D
mm
K
A
F
C
N
E
H
Handle
Swing
D
A
F
B
E
H
Handle
Swing
D
B
Y
O
G C
E B
G C
Y
(4) .31 Dia. Mtg. Holes
8 (For Size 0, 1, & 2)
(4) .31 Dia. Mtg. Holes
8 (For Size 0, 1, & 2)
Cover Open 90°
Cover Open 90°
F
L
J
W
W X W
G
J
(4) .31 Dia. Mtg. Holes
8 (For Size 0, 1, & 2)
X
J
I
H
I
Figure 1
NEMA Type 1 Enclosure
K
Figure 2
NEMA Type 4 Enclosure
I
Figure 3
NEMA Type 12 Enclosure
52
© 1998 Square D All Rights Reserved
5/98
Square D Company
8001 Highway 64 East
Knightdale, NC 27545-9023
(919) 266-3671
UL is a registered trademark of Underwriters Laboratories, Inc.
CSA is a registered trademark of Canadian Standards Association.
MOTOR LOGIC is a trademark of Square D Company.
Spin Top, Square D and
are registered trademarks of Square D Company.
Catalog No. 8502CT9701 May 1998 © 1998 Square D All Rights Reserved.