datasheet for CLL131 by Clairex

datasheet for CLL131 by Clairex

®
CLL Series
Clairex
Technologies, Inc.
Photo-IC Sensors
Digital Output
March, 2003
1. OUTPUT
1. OUTPUT
2. VCC
2. VCC
0.500(12.7) min.
0.500(12.7) min.
0.157 (3.99)
0.210 (5.33)
(3.48)
0.2100.137
(5.33)
0.190 (4.83)
0.190 (4.83)
TO-72
4
4
3
0.187 (4.75)
0.187 (4.75)
0.179 (4.55)
0.179 (4.55)
3. GROUND
3. GROUND
4. ADJUST
4. ADJUST
0.048 (1.22)
0.048 (1.22)
0.028 (0.71)
0.028 (0.71)
3
2 2
0.046
(1.17)
0.046
(1.17)
0.036
(0.91)
0.036
(0.91)
1 1
0.030
(0.76)
max.
0.030
(0.76)
max.
0.230
(5.84)
0.230
(5.84)
0.209
(5.31)
0.209
(5.31)
0.060max
(1.52) max
0.060 (1.52)
CLL130
CLL131
CLL133
45°45°
Case 21
0.500(12.7) min.
0.210 (5.33)
0.190 (4.83)
1. OUTPUT
3. GROUND
2. VCC
4. ADJUST
TO-72
4
0.048 (1.22)
0.028 (0.71)
3
0.187 (4.75)
0.179 (4.55)
2
0.046 (1.17)
0.036 (0.91)
1
CLL130W
CLL131W
CLL133W
0.030 (0.76) max.
0.230 (5.84)
0.209 (5.31)
0.010 (0.25) max
45°
Case 22
0.500(12.7) min.
features
• Output stages:
a. Buffer or inverter
b. Open collector or internal
10K pull-up
• Supply voltage 4.5V to 18V
• 7:1 user sensitivity adjustment
on CLL130-CLL133 and
CLL130W-CLL133W series
• Acceptance angle:
a. ± 15° high dome lens can
b. ± 35° flat window lens can
• Operates to 125°C
• RoHS compliant
description
The CLL series are monolithic
integrated circuits incorporating a
photodiode, linear amplifier, Schmitt
trigger for hysteresis and pulse
shaping, and digital output with either
10K pull-up or open collector. The
series includes TO-72 four leaded
packages (with user adjustable gain)
and TO-18 three leaded packages in
both high dome and flat window
configurations. Alternate pin-outs
are available. Contact Clairex.
0.210 (5.33)
0.190 (4.83)
1. OUTPUT
3. GROUND
2. VCC
4. ADJUST
4
0.048 (1.22)
0.028 (0.71)
3
0.187 (4.75)
0.179 (4.55)
2
0.046 (1.17)
0.036 (0.91)
1
0.030 (0.76) max.
0.230 (5.84)
0.209 (5.31)
0.060 (1.52) max
CLL134
CLL135
CLL136
CLL137
45°
Case 21
0.500(12.7) min.
0.210 (5.33)
0.190 (4.83)
1. OUTPUT
3. GROUND
2. VCC
4. ADJUST
4
0.048 (1.22)
0.028 (0.71)
3
0.187 (4.75)
0.179 (4.55)
2
0.046 (1.17)
0.036 (0.91)
1
0.030 (0.76) max.
0.230 (5.84)
0.209 (5.31)
0.010 (0.25) max
TO-18
CLL134W
CLL135W
CLL136W
CLL137W
45°
Case 22
ALL DIMENSIONS ARE IN INCHES (MILLIMETERS)
Clairex reserves the right to make changes at any time to improve design and to provide the best possible product.
Clairex Technologies, Inc.
Phone: 972-265-4900
TO-18
1301 East Plano Parkway
Fax: 972-265-4949
Revised 3/16/06
Page 1 of 4
Plano, Texas 75074-8524
www.clairex.com
®
CLL Series

Clairex
Technologies, Inc.
Photo-IC Sensors
Digital Output
Schematics
VREG
VCC
VCC
VREG
ADJ
VOUT
LA
VOUT
LA
GND
CLL133/CLL133W
Open collector – inverter with Adjust
VREG
ADJ
GND
CLL135/CLL135W
Open collector - inverter
VREG
VCC
VCC
10k
VOUT
VOUT
LA
LA
GND
GND
10k
CLL131/CLL131W
pull-up – inverter with Adjust
VREG
VCC
VREG
ADJ
CLL134/CLL134W
Open collector - buffer
VCC
10k
10k
VOUT
VOUT
LA
LA
GND
GND
10k
CLL137/CLL137W
10k pull-up – inverter
CLL130/CLL130W
pull-up – buffer with Adjust
VREG
VCC
10k
VOUT
LA
GND
CLL136/CLL136W
10k pull-up – buffer
Clairex reserves the right to make changes at any time to improve design and to provide the best possible product.
Clairex Technologies, Inc.
Phone: 972-265-4900
1301 East Plano Parkway
Fax: 972-265-4949
Page 2 of 4
Plano, Texas 75074-8524
www.clairex.com
®
CLL Series

Clairex
Technologies, Inc.
Photo-IC Sensors
Digital Output
Absolute maximum ratings (TA = 25°C unless otherwise stated)
storage temperature ........................................................................................................ -65°C to +150°C
operating temperature ..................................................................................................... -65°C to +125°C
lead soldering temperature(1) ............................................................................................................260°C
VCC supply voltage...................................................................................................................4.5V to 18V
VADJ (CLL130-CLL133 and CLL130W-CLL133W only) ......................................................................... 3V
VOUT (10k pull-up series)(2) ................................................................................................................ 18V
VOUT (open collector series)(2) .............................................................................................................. 30V
ISINK(3) ................................................................................................................................................ 25mA
continuous power dissipation(4) ..................................................................................................... 250mW
NOTES:
1. 1/16” from the case for 5 seconds maximum.
2. This rating applies when the output is in the OFF state only.
3. This rating applies when the output is in the ON state only.
4. Derate linearly 2.0mW/°C from 25°C free air to TA = 125°C.
5. CLL130-CLL133 and CLL130W-CLL133W photo-IC sensors are tested with the ADJ lead open.
6. Light source is an AlGaAs IRED with peak wavelength at 850nm.
DEFINITIONS:
• Ee (+) is the minimum irradiance required to cause the output to change state.
• Buffer: Output is HIGH when input irradiance is >Ee (+).
• Inverter: Output is LOW when input irradiance is >Ee (+).
electrical characteristics (TA = 25°C unless otherwise noted)
parameter
symbol
min
typ
max
units
Operating supply voltage
VCC
4.5
-
18
Positive going threshold
irradiance(6)
0.005
-
0.05
V
mW/cm2
Ee (+)
0.025
-
0.25
mW/cm2
Hysteresis ratio
EeT (+)
EeT (-)
1.1
-
1.8
Supply current
ICC
-
-
12
mA
4.5V ≤ VCC ≤ 18V, Ee = 0
or 0.5mW, ADJ open
P
-
30
70
-
deg.
deg.
All non-suffix W parts
All suffix W parts
Total acceptance angle
test conditions
4.5V ≤ VCC ≤ 18V, ADJ open,
All non-suffix W parts.
All suffix W parts.
operate point/release point
Gain threshold can be adjusted on the CLL130-CLL133 and CLL130W-CLL133W series by
placing a resistor between the ADJ and GND leads in accordance with the following table.
Decreasing the resistance causes the output to switch at a higher threshold level.
ADJ Resistor
open
10k
4.7k
2.2k
1k
Connected to GND
Normalized Threshold
1.00
2.00
2.75
3.75
5.00
7.25
Clairex reserves the right to make changes at any time to improve design and to provide the best possible product.
Clairex Technologies, Inc.
Phone: 972-265-4900
1301 East Plano Parkway
Fax: 972-265-4949
Page 3 of 4
Plano, Texas 75074-8524
www.clairex.com
®
CLL Series

Clairex
Technologies, Inc.
Photo-IC Sensors
Digital Output
electrical characteristics (TA = 25°C unless otherwise noted)
parameter
symbol
min
typ
CLL130/CLL130W and CLL136/CLL136W (buffer, 10k pull-up)
max
units
High state output voltage
VOH
4.5
-
-
V
Low state output voltage
Output rise and fall time
VOL
tr, tf
-
75
0.4
-
V
ns
tPHL, tPLH
-
5
-
µs
pull-up)
-
-
V
Propagation delay
CLL131/CLL131W and CLL137/CLL137W (inverter, 10k
High state output voltage
VOH
4.5
Low state output voltage
VOL
-
-
0.4
V
Output rise and fall time
tr, tf
-
75
-
ns
tPHL, tPLH
-
5
-
µs
Propagation delay
test conditions
VCC = 5.0V,
Ee (+) ≥ 0.5mW/cm2
VCC = 5.0V, Ee (+) = 0
VCC = 5.0V, Ee = 0 or
0.5mW/cm2, f = 10kHz,
D.C. = 50%, RL = 330
VCC = 5.0V, Ee (+) = 0
VCC = 5.0V,
Ee (+) ≥ 0.5mW/cm2
VCC = 5.0V, Ee = 0 or
0.5mW/cm2, f = 10kHz,
D.C. = 50%, RL = 330
CLL134/CLL134W (buffer, open collector)
High state output current
IOH
-
-
100
µA
Low state output voltage
VOL
-
-
0.4
V
Output rise and fall time
tr, tf
-
75
-
ns
tPHL, tPLH
-
5
-
µs
Propagation delay
VCC = 5.0V, VOH = 30V
Ee (+) ≥ 0.5mW/cm2
VCC = 5.0V, Ee (+) = 0
RL = 330
VCC = 5.0V, Ee = 0 or
0.5mW/cm2, f = 10kHz,
D.C. = 50%, RL = 330
CLL133/CLL133W and CLL135/CLL135W (inverter, open collector)
High state output current
IOH
-
-
100
µA
Low state output voltage
VOL
-
-
0.4
V
Output rise and fall time
tr, tf
-
75
-
ns
tPHL, tPLH
-
5
-
µs
Propagation delay
VCC = 5.0V, VOH = 30V
Ee (+) = 0
VCC = 5.0V, RL = 330
Ee (+) ≥ 0.5mW/cm2
VCC = 5.0V, Ee = 0 or
0.5mW/cm2, f = 10kHz,
D.C. = 50%, RL = 330
NOTE: Due to the high sensitivity of the CLL series, when used in high speed switching
applications, Clairex recommends installing a 0.1µF capacitor between VCC and GND.
Clairex reserves the right to make changes at any time to improve design and to provide the best possible product.
Clairex Technologies, Inc.
Phone: 972-265-4900
1301 East Plano Parkway
Fax: 972-265-4949
Page 4 of 4
Plano, Texas 75074-8524
www.clairex.com