Manual 8499691
Contents
p. 2
Applic.
pp. 4-8
Selection
pp. 9-11
Products
pp. 12-87
GenRad
products
pp. 50-87
Index
p. 89
VI-700 Series
Precision Manual or
Programmable Voltage and Current Source
Various features and options make the VI-700
an effective choice for many manual and programmable voltage and current applications.
s
n
o
ati
c
cifi
e
p
ds
e
v
o
r
Current output range of 0.1 μA to 20 mA or p
200
m
I
mA
Voltage output range of 100 μV to 20 V or 200 V
3½ digit resolution, 0.75 LSD accuracy
Manual thumbwheel operation or programmable
digital input, IEEE-488 or parallel BCD interface.
Optional portable power pack
May be used as a component in a closed loop
control system
Model VI-700 Precision Voltage and Current Source
SPECIFICATIONS
Voltage
Output Ranges
Resolution
Accuracy
Output Current
Output
Impedance
Noise and
Ripple
200 mV, 2 V, 20 V;
(200 V with HV option).
100 μV, 1 mV, 10 mV;
(100 mV with HV option).
±(75 ppm + 50 μV); 200 mV range;
±(75 ppm + 0.25 mV), 2 V range;
±(75 ppm + 2.5 mV), 20 V range;
at 23°C, no load, after warmup.
70 mA, (200 mA with HP option) maximum
load up to 20 V; (10 mA for 200 V range with
HV option); with LED overload indicator.
5 mΩ typical, 40 mΩ for 20 V range.
50 μVrms on 200 mV and 2 V ranges;
50 μVrms on 200 mV and 2 V ranges;
100 μVrms on 20 V range.
±10 ppm/°C typical;
±15 ppm/°C max.
Tempco
Current
Output Ranges
200 μA, 2 mA, 20 mA,
200 mA (with HI option).
Resolution
0.1 μA, 1 μA, 10 μA;
100 μA (with HI option).
Accuracy±(75 ppm + .05 μA); 200 μA;
±(75 ppm + 0.25 μA), 2 mA;
±(75 ppm + 2.5 μA), 20 mA; 23°C, no load.
Compliance
0-20 V; with LED overload indicator.
Voltage
Noise
8-20 nA.
Digital Input
Isolation
Floating outputs, optically isolated from
digital inputs; voltage and current outputs may be used in either polarity.
Power
Requirements
Dimensions
105-125 V or 210-250 V;
50-60 Hz; 5 W.
21.6 cm W x 12.6 cm H x 22.9 cm D
(8.5" x 2.8" x 9.0" ) for Standard Model;
21.6 cm W x 8.7 cm Hx 23.5 cm (8.5"
x 3.44" x 9.25" ) for IEEE-488 interface
option.
2.3 kg (5 lb).
Weight
Operating Temperature Range: 10°C to 40°C.
StorageTemperature Range: -40°C to 60°C.
ORDERING INFORMATION
Model VI-700-110
Model VI-700-220
-HP Option
-HI Option
-HV Option
-RS Option
-BCD Option
-IEEE Option
IEEE-488
IEEE-488
BP-511
IET LABS, INC. in the GenRad Tradition
534 Main Street, Westbury, NY 11590
IET cat/VI-700, Rev J3/01-17-05
General
31/2 digit parallel BCD or IEEE-488
interface; a front panel push-button
selects REMOTE or LOCAL operation.
Precision Voltage & Current Source; 110 Vac op.
Precision Voltage & Current Source; 220 Vac op.
High power output, up to 200 mA output
200 mA output (in addition to 200 μA-20 mA)
200 V output (in addition to 100 μV -10 mV)
Remote sensing directly to load
Parallel BCD Remote Programming
IEEE-488 Remote Programming
Interface hardware (see p. 48)
Interface software (see pp. 46-47, 49)
Battery Pack, AC source, 115 V, 60 Hz, 300 W
(see p. 48)
www.ietlabs.com
TEL: (516) 334-5959 • (800) 899-8438 • FAX: (516) 334-5988