250 0375

250 0375
VFD05-D230-PCM
Variable Frequency Drives
for 3-phase & single phase AC motors
Q U I C K
S T A R T
G U I D E
D I M E N S I O N S
5.625 [143]
C501
JMP504
1 2 3
TB501
4mA
ZERO
SET
JMP505
MIN
IC501
C502
MAX
IL504
0.188 [5]
* Jumper settings MUST match input line voltage. Application of 230 VAC line input when jumpers are set for 115 VAC will
result in severe damage to the drive.
ACCEL
ENABLE
BRAKE
IL501
IL502
COAST
POWER FAULT
JMP506
DECE
SL
COM
J501
Q14
1-Phase Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .*115/230 VAC
1 or 3 -Phase Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .230 VAC
Maximum Horsepower . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.5 HP
Maximum Continuous Output Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . † 5.0 AC
AC Amps In . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 / 10 amps
AC Voltage Input Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .115/230 VAC ± 10%
50/60 Hz single phase
Standard Carrier Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 KHz
Adjustable Braking Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0 - 5 ADC
Adjustable Braking Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 - 10 Sec.
Adjustable Minimum Speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0 - 30 Hz
Output Frequency Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0 - 120 Hz
Adjustable Maximum Output Frequency Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 - 120 Hz
Acceleration Time Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 - 12 secs
Deceleration Time Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 - 12 secs
Analog Input Voltage Range
(S1 [-] to S2 [+]) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 - 5 VDC, 0 - 10 VDC, 4 - 20 mA
Input Impedance, S1 to S2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .~ 100K ohms
Vibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.5G max (20 - 50 Hz)
0.1G max (> 50 Hz)
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.2 lbs
Ambient Operating Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10° - 40° C
T501
I
IL501
JMP503
UV TRIP
RESTART
T
S P E C I F I C A T I O N S
C O N N E C T I O N S
C501
BOOS
IL503
Q13
R8
R88
TORQUE
LIMIT
R8
R89
8
JMP501
7.200 [183]
D20
FOR 115VAC
D21
R76
R7
R75
BR501
C3
C35
6.350 [161]
C34
Q11
C503
D19
C502
C508
JMP504
INPUT SELECT
1-2 = VDC
2-3 = mA
R84
JMP505
RANGE SELECT
1 = 0 - 5 VDC
2 = 0 - 10 VDC
3 = 4 - 20 mA
FU5
SCR501
C38
C28
R8
R80
BRAKE
CURRENT
FU502
D18
SCR502
BRAK
TIM
230 VAC
JMP502
115 VAC
0.850 [22]
C504
L1
L2
U
V
W
TB502
ALL DIMENSIONS IN INCHES [MILLIMETERS]
Maximum Height (C1 & C2): 3.30 [84]
STEP #1
Connect the enable/disable switch, direction switch, and speed potentiometer or signal
input to TB501 on the TOP board using 20 - 24 AWG wire as shown below.
C O N N E C T I O N S
STEP #2
Configure jumpers JMP504 and JMP505 on the top board for the appropriate signal input.
1
2
2
STEP #5
Connect motor leads of a 3-phase motor to U, V, and W (TB502 on BOTTOM board) using 14 - 16
AWG wire as shown in the figure below.
3
JMP504
1
( c o n t . )
JMP504 (on top board)
Pins 1 & 2 for Voltage Input, or using a speed pot.
Pins 2 & 3 for Current Input
STEP #6
Connect 115 or 230 VAC power input using 12 AWG wire. Include a start/stop switch as shown in the
figure below.
3
JMP505 (on top board)
1 for 0 - 5 VDC Voltage Input, or using a speed pot
2 for 0 - 10 VDC Voltage Input
3 for 4 - 20 mA Current Input
JMP505
STEP #3
Configure jumpers JMP503 on the bottom board and JMP506 on the top board.
JMP503
JMP503 (on bottom board)
Pins 1 & 2 to Trip
Pins 2 & 3 to Restart
1
2
3
UV TRIP
RESTART
1
2
3
BRAKE
COAST
TRIP: Drive has a low voltage fault & must
be manually re-enabled to restart.
RESTART: Drive has a low voltage fault &
will momentarily stop then auto-restart
when input voltage returns to minimum level.
JMP506 (on top board)
Pins 1 & 2 to Brake
Pins 2 & 3 to Coast
JMP506
STEP #4
Configure jumpers JMP501 and JMP502 on the bottom board for 115 or 230 VAC Power
Input. A jumper must be installed on JMP501 for 115 VAC input. No jumper is necessary
on JMP501 for 230 VAC input.
M I N A R I K D R I V E S
w w w . m i n a r i k d r i v e s . c o m
14300 De La Tour Drive, South Beloit, IL 61080;
Phone: (800) MINARIK (646-2745); Fax: (815) 624-6960
Document Number: 250-0375, Revision 2; Printed in the U.S.A. - May 2005
Copyright 2005 by Minarik Corporation - All rights reserved. No part of this document may be reproduced or transmitted in any form without written permission from
Minarik Corporation. The information and technical data in this document are subject to change without notice. Minarik Corporation and its Divisions make no
warranty of any kind with respect to this material, including, but not limited to, the implied warranties of its merchantability and fitness for a given purpose. Minarik
Corproation and its Divisions assume no responsibility for any errors that may appear in this document and make no commitment to update or to keep current the
information in this document. mvd092503
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement