WARNING!
This equipment is similar to other gate or door equipment and meets or exceeds
Underwriters Laboratory Standard 325 (UL 325). However, gate equipment has
hazards associated with its use and therefore by installing this product the installer
and user accept full responsibility for following and noting the installation and
safety instructions. Failure to follow installation and safety instructions can result
in hazards developing due to improper assembly. You agree to properly install this
product and that if you fail to do so Gates That Open, LLC, (“GTO”) shall in no event
be liable for direct, indirect, incidental, special or consequential damages or loss of
profits whether based in contract tort or any other legal theory during the course
of the warranty or at any time thereafter. The installer and/or user agree to assume
responsibility for all liability and use of this product releasing Gates That Open, LLC,
from any and all liability. If you are not in agreement with this disclaimer or do not
feel capable of properly following all installation and safety instructions you may
return this product for full replacement value.
READ ALL INSTRUCTIONS CAREFULLY AND COMPLETELY before attempting to
install and use this automatic gate operator. This gate operator produces a high level
of force. Stay clear of the unit while it is operating and exercise caution at all times.
All automatic gate operators are intended for use on vehicular gates only.
This product meets and exceeds the requirements of UL 325, the standard which
regulates gate operator safety, as established and made effective March 1, 2000, by
Underwriters Laboratories Inc.
®
, LLC
For more information on the GTO/ACCESS SYSTEMS full line of automatic gate
operators and access controls visit our website at www.gtoaccess.com.
©2010 Gates That Open, LLC
Printed in China for Gates That Open, LLC.
R2000 INST 120310
Certification and Product Usage
The GTO 2000XL Gate Operator is intended for use with vehicular swing gates in single-family residential
applications. The operator is system certified to be in compliance with UL 325, current edition, as of publication date.
Product tested to the latest UL-325 standard by ETL. Product tested to be in compliance with CAN/CSA-C22.2
No. 247-92.
Product tested to be in compliance with IEC 60335-2-103:2003 and IEC 60335-1:2004, including A1:2004.
Converting Metric Units to English Equivalents
When You Know
Multiply By
To Find
Symbol
centimeters
meters
kilograms
0.3937
3.2808
2.2046
inches
feet
pounds
in. (or ")
ft. (or ')
lb. (or #)
Converting English Units to Metric Equivalents
When You Know
Multiply By
inches
feet
pounds
2.5400 centimeterscm
0.3048meters m
0.4535 kilogramskg
Converting Temperature
deg. Celsius
deg. Fahrenheit
(°C x 1.8) + 32
(°F-32) ÷ 1.8
To Find
deg. Fahrenheit
deg. Celsius
Symbol
°F
°C
FOR YOUR RECORDS
Please record the following information product serial number (located on right side of control box), be sure to
keep all receipts for proof of purchase. Refer to this information when calling GTO for service or assistance
with your automatic gate opener.
Serial Number:____________________________________
Date of Purchase:_________________
Place of Purchase:____________________________________________________________________
Table of Contents
Class Rating.......................................................................................................................inside cover
Please Read This First...........................................................................................................................ii
Important Safety Instructions........................................................................................................ iii
Technical Specifications..................................................................................................................... 1
Before You Begin.................................................................................................................................. 2
Determine Charging Option for Battery: Transformer OR Solar.................................. 2
Solar Panel and Gate Activity Chart........................................................................................ 2
Check Direction of Gate Swing................................................................................................. 3
Prepare the Gate............................................................................................................................ 3
2000XL Parts List............................................................................................................................ 4
Tools Needed................................................................................................................................... 5
Materials You may Need for the Installation: ...................................................................... 5
Installation Overview................................................................................................................... 6
Install the Operator............................................................................................................................. 8
Install the Post Bracket Assembly............................................................................................ 8
Check Clearance............................................................................................................................. 9
Install Gate Bracket......................................................................................................................10
Attach Operator Arm .................................................................................................................10
Installation of the Closed Position Stop Plate ...................................................................11
Mount the Control Box and Receiver....................................................................................12
Connect Operator Power Cable..............................................................................................13
Connect the Transformer..........................................................................................................14
Connect Battery............................................................................................................................15
Program Control Board....................................................................................................................16
Set the Closed Position Limit (for Pull-To-Open Applications)....................................16
Adjust the Stall Force Setting..................................................................................................17
Set Auto Close Time....................................................................................................................18
Program Your Personal Transmitter Setting.......................................................................18
Control Board Settings...............................................................................................................19
Connnecting Accessories................................................................................................................20
Wiring Accessories.......................................................................................................................21
Connecting Other Auxiliary Devices (Sirens, Lights, etc.)..............................................21
Push-To-Open Installation Information.....................................................................................22
Setting the Open Position Limit (Push-To-Open Installations)....................................23
Column Installation...........................................................................................................................24
Troubleshooting Guide....................................................................................................................25
Voltage Ratings.............................................................................................................................26
Repair Service................................................................................................................................27
Accessories...........................................................................................................................................28
Please Read This First
®
, LLC
Thank you for purchasing a GTO/ACCESS SYSTEMS 2000XL. When correctly installed and properly used,
your 2000XL operator will give you many years of reliable service. Please read the following information
to ensure you have the correct system for your particular needs. This manual will enable you to properly
install your 2000XL Automatic Gate Operator.
The 2000XL operator is designed for installation on a pull-to-open single leaf gate. The gate must not
exceed 16 feet in length nor weigh more than 500 pounds* (please see Technical Specifications on page
1). The 2000XL operator can be used on vinyl, aluminum, chain link, farm tube, and wrought iron gates.
Use on solid (wood) gates is not recommended. Solid surface gates have a high resistance to the wind.
If the wind is strong enough, the operator will obstruct, stop, and blow fuses.
The 2000XL operator accommodates extra transmitters, digital keypads, solar panels, push buttons,
automatic gate locks, and other access control products. These optional accessories are noted with the
symbol.
The 2000XL operator features adjustable stall force. This safety feature makes the gate stop and reverse
direction within two seconds when it comes in contact with an obstruction. The “MIN” setting means the
gate will exert the minimum force on an obstruction before it stops and reverses direction.
The 2000XL operator also has an adjustable auto-close feature. It can be set to remain open from 3 to
120 seconds before automatically closing. Pressing the transmitter button at any time after the gate fully
opens will cause it to close immediately. “OFF” is the factory setting; meaning the gate will stay open until
you press the transmitter button (or keypad, etc.) again.
Please call GTO at (800) 543-GATE [4283] or (850) 575-0176 for more information about our GTO/ACCESS
SYSTEMS professional line of gate operators and accessories. Our Sales Department will be glad to give
you the name and phone number of a GTO/ACCESS SYSTEMS dealer near you.
BEFORE YOU BEGIN TO INSTALL YOUR AUTOMATIC GATE OPERATOR:
Read these instructions carefully and completely to become familiar with all parts and installation
steps. You must read the installation manual for detailed instructions on gate operator safety
and proper use of the gate operator.
24/7 Troubleshooting Wizard: http://support.gtoinc.com
GTO Accessories are noted with this symbol in this Installation
Manual. Information about accessories can be found on page 28
and at www.gtoaccess.com.
ii GTO 2000XL Instruction Manual © 120310
IMPORTANT SAFETY INSTRUCTIONS
Because automatic gate operators produce high levels of force, consumers need to know the potential
hazards associated with improperly designed, installed, and maintained automated gate operator
systems. Keep in mind that the gate operator is just one component of the total gate operating system.
Each component must work in unison to provide the consumer with convenience, security, and safety.
This manual contains various safety precautions and warnings for the consumer. Because there are
many possible applications of the gate operator, the safety precautions and warnings contained in
this manual cannot be completely exhaustive in nature. They do, however, provide an overview of the
safe design, installation, and use of this product. CAREFULLY READ AND FOLLOW ALL SAFETY
PRECAUTIONS, WARNINGS, AND INSTALLATION INSTRUCTIONS TO ENSURE THE SAFE
SYSTEM DESIGN, INSTALLATION, AND USE OF THIS PRODUCT.
warning symbol. The symbol
Precautions and warnings in this manual are identified with this
identifies conditions that can result in damage to the operator or its components, serious injury, or
death.
Because GTO automatic gate operators are only part of the total gate operating system, it is the
responsibility of the installer/consumer to ensure that the total system is safe for its intended
use.
How To Manually Open and Close the Gate:
CAUTION: The gate can be opened and closed manually when the operator is disconnected.
ONLY disconnect the operator when the operator power switch is OFF and the gate is NOT moving.
Disconnecting the Operator
1. Turn operator power switch (Control Box) OFF.
2. Remove hairpin clip, clevis pin, and bushing from both the
front and rear mounting points.
Front Mount
Clevis Pin
3. Remove the operator from the mount.
Gate Bracket
Bushing
CAUTION: Because the GTO gate operator is battery
powered, disconnect the operator ONLY when the power
switch on the contol box is turned OFF. Unplugging the
transformer does not turn power to the operator OFF.
Hairpin Clip
[FM345] for the clevis pin on the front
NOTE: Substitute a Pin Lock
mount of the gate operator to prevent unauthorized removal of the
operator from the gate. GTO 2000XL Instruction Manual © 120310
iii
IMPORTANT SAFETY INSTRUCTIONS
For The Consumer
WARNING: To reduce the risk of injury or death:
1.
READ AND FOLLOW ALL INSTRUCTIONS. Failure to meet the requirements set forth in the instruction manual
could cause severe injury or death, for which the manufacturer cannot be held responsible.
2. When designing a system that will be entered from a highway or main thoroughfare, make sure the system is placed
far enough from the road to prevent traffic congestion.
3. The gate must be installed in a location that provides adequate clearance between it and adjacent structures when
opening and closing to reduce the risk of entrapment. Swinging gates must not open into public access areas.
4. The gate and gate operator installation must comply with any applicable local codes.
I. Before Installation
1. Verify this operator is proper for the type and size of gate, its frequency of use, and the proper class rating.
2. Make sure the gate has been properly installed and swings freely in both directions. Repair or replace all worn or
damaged gate hardware prior to installation. A freely moving gate will require less force to operate and will enhance
the performance of the operator and safety devices used with the system.
3. Review the operation of the system to become familiar with its safety features. Understand how to disconnect the
operator for manual gate operation (page iii).
4. This gate operator is intended for vehicular gates ONLY. A separate entrance or gate must be installed for
pedestrian use (page vi).
5. Always keep people and objects away from the gate and its area of travel. NO ONE SHOULD CROSS THE PATH
OF A MOVING GATE.
6. Pay close attention to the diagram below and be aware of these areas at all times.
ZONE 2
ZONE 1
ZONE 5
ZONE 3
ZONE 4
Driveway
Gate in the
Open Position
Entrapment Zones for a proper Pull-To-Open installation:
Zone 1 – leading edge of the gate and post.
Zone 2 – between the gate and the gate post.
Zone 3 – the path of the gate.
Zone 4 – the space between the gate in the open position and any object such as a wall, fence, etc.
Zone 5 – pinch points between the operator and gate.
iv GTO 2000XL Instruction Manual © 120310
IMPORTANT SAFETY INSTRUCTIONS
II. During Installation
1. Install the gate operator on the inside of the property and fence line. DO NOT install an operator on the outside of
the gate where the public has access to it.
2. Be careful with moving parts and avoid close proximity to areas where fingers or hands could be pinched.
3. Devices such as contact sensors (safety edges) and non contact sensors (photo beams) provide
additional protection against entrapment.
4. If push buttons or keypads are installed, they should be within sight of the gate, yet located at least 10 feet from any
moving part of the gate (see diagram below). Never install any control device where a user will be tempted to
reach through the gate to activate the gate operator.
5. Do not activate your gate operator unless you can see it and can determine that its area of travel is clear of people,
pets, or other obstructions. Watch the gate through its entire movement.
6. Secure outdoor or easily accessed gate operator controls in order to prohibit unauthorized use of the gate.
10'
10'
10'
Moving Gate
Area
Driveway
NEVER INSTALL
any control device
within gray area
10'
III. After Installation
1. Attach the warning signs (included) to each side of the gate to alert the public of auto­matic gate operation. It
is your responsibility to post warning signs on both sides of your gate. If any of these signs or warning decals
become damaged, illegible or missing, replace them immediately. Contact GTO for free replacements.
2. The gate is automatic and could move at any time, posing a serious risk of entrapment. No one should be in
contact with an activated gate when it is moving or stationary.
3. Do not attempt to drive into the gate area while the gate is moving; wait until the gate comes to a complete stop.
4. Do not attempt to “beat the gate” (drive through) while the gate is closing. This is extremely dangerous.
5. Do not allow children or pets near your gate. Never let children operate or play with gate controls. Keep ALL
gate controls away from children and unauthorized users; store controls where children and unauthorized users do
not have access to them.
6.
KEEP GATE AND GATE OPERATOR PROPERLY MAINTAINED. Always turn power to operator OFF before
performing any maintenance. Regularly grease the gate hinges. Clean the push-pull tube with a soft, dry cloth and
apply silicone spray to it at least once per month.
GTO 2000XL Instruction Manual © 120310
v
IMPORTANT SAFETY INSTRUCTIONS
7. To operate this equipment safely, YOU must know how to disconnect the operator for manual gate operation (page
iii). If you have read the instructions and still do not understand how to disconnect the operator, contact the GTO
Service Department.
8. Disconnect the operator ONLY when the power is TURNED OFF and the gate is NOT moving.
9. Make arrangements with local fire and law enforcement for emergency access.
10. Distribute and discuss copies of the IMPORTANT SAFETY INSTRUCTIONS section of this manual with all
persons authorized to use your gate.
11.IMPORTANT: Save these safety instructions. Make sure everyone who is using or will be around the gate
and gate operator are aware of the dangers associated with automated gates. In the event you sell the
property with the gate operator or sell the gate operator, provide a copy of these safety instructions to
the new owner.
Should you lose or misplace this manual, a copy can be obtained by downloading one from the GTO web site
(www.gtoaccess.com), by contacting Gates That Open, LLC., at 3121 Hartsfield Road, Tallahassee, Florida
32303 or by calling 1-800-543-4283 and requesting a duplicate copy. One will be provided to you free of
charge.
Required Safety Precautions for Gates
Install Warning Signs
Warning signs alert people of automatic gate operation and are required when installing the GTO Gate Operator. The
Warning Signs included must be installed on both sides of each gate. Furthermore, a walk-through gate must be installed
for pedestrian traffic. We recommend using the GTO Bulldog Pedestrian Gate Lock [FM145] for controlled access.
Entrapment Protection
GTO’s inherent obstruction settings, even when properly adjusted, may not be sensitive enough to prevent bodily
injury in some circumstances. For this reason, safety devices such as safety edge sensors (or photoelectric sensors),
which stop and reverse gate direction upon sensing an obstruction, are suggested for enhanced protection against
entrapment.
GTO Bulldog Pedestrian
Gate Lock
(recommended, not included)
Contact Sensor
Pedestrian Gate
(recommended, not included)
Warning Sign
Vehicular Gate
Photo Beam
(recommended, not included)
vi GTO 2000XL Instruction Manual © 120310
Contact Sensor
Contact Sensor
Photo Beam
(recommended, not included) (recommended, not included) (recommended, not included)
IMPORTANT SAFETY INSTRUCTIONS
Secondary Means of Protection Against Entrapment
As specified by Gate Operator Safety Standard, UL 325 (30A.1.1), automatic gate operators shall have an inherent
entrapment sensing system, and shall have provisions for, or be supplied with, at least one independent secondary
means to protect against entrapment. The 2000XL utilizes Type A, an inherent (i.e., built-in) entrapment sensing system
as the primary type of entrapment protection. Also, the 2000XL has provisions for the connection of Type B1 or B2
protection to be used as the secondary type of entrapment protection, if desired.
1. For gate operators utilizing a non-contact sensor (e.g., photo-electric sensor– Type B1) in accordance with UL 325
(51.8.4 [h]):
A. Refer to the sensor manufacturer’s instructions on the placement of non-contact sensors for each type of
application.
B. Care shall be exercised to reduce the risk of nuisance tripping, such as when a vehicle trips the sensor while the
gate is still moving.
C. One or more non-contact sensors shall be located where the risk of entrapment or obstruction exists, such as the
perimeter reachable by a moving gate or barrier.
2.
For gate operators utilizing a contact sensor (e.g., safety edge sensor– Type B2) in accordance with UL 325 (51.8.4 [i]):
A. One or more contact sensors shall be located at the leading edge, bottom edge, and post edge, both inside and
outside of a vehicular swing gate system.
B. A hard wired contact sensor shall be located and its wiring arranged so that the communication between the
sensor and the gate operator is not subjected to mechanical damage.
C. A wireless contact sensor such as one that transmits radio frequency (RF) signals to the gate operator for
entrapment protection functions shall be located where the transmission of the signals are not obstructed or
impeded by building structures, natural landscaping or similar obstruction. A wireless contact sensor shall
function under the intended end-use conditions.
You may want to consider adding photo beams to your installation. GTO Photo Beams
means of entrapment protection.
[R4222] provide a “non contact”
Leading Edge Contact Sensor
on both sides of the gate
Vehicular Gate
Photo Beam
Bottom Edge Contact Sensor
on both sides of the gate
Post Edge Contact Sensor
on both sides of the gate
Photo Beam
ENTRAPMENT ALARM (UL 325; 30A.1.1A)
The 2000XL Gate Operator is designed to stop and reverse within 2 seconds when the gate comes in contact with
an obstruction. Additionally, these operators are equipped with an audio entrapment alarm which will activate if the
unit obstructs twice while opening or closing. This alarm will sound for a period of 5 minutes, or until the operator
receives an intended signal from a hard wired entry/exit source (e.g. push button control or keypad) and the gate
returns to a fully open or fully closed position. Turning the power switch on the control box OFF and back ON will also
deactivate the alarm. Wireless controls such as transmitters and wireless keypads will not deactivate the alarm.
GTO 2000XL Instruction Manual © 120310
vii
IMPORTANT SAFETY INSTRUCTIONS
!
DC SWING SERIES
C
LIS ED
T
9901178
US
Conforms to UL 325 STANDARDS
Maximum Gate: 500 lb. (226.7 kg); 16 ft. (4.8 m)
Voltage: 12 Vdc; Frequency: 0 Hz; Power: 25 W
Class I Vehicular Swing Gate Operator.
Serial Number: SW2000-0000000
TO MANUALLY OPEN AND CLOSE THE GATE:
1. Turn control box power switch OFF.
2. Disconnect front or rear mount from mounting bracket.
3. Pull operator away from mounting brackets and move gate.
Disconnect operator ONLY when the control box power
switch is OFF and the gate is NOT moving.
XXXXXX
Product identification and manual operation instruction
label (1) installed on right hand side of control box.
Warning signs (2 enclosed) to be installed on each side
of the gate (3–5 feet above the bottom of the gate).
ACCESS
SYSTEMS
PROFESSIONAL RESIDENTIAL
2000XL
1-800-543-GATE (4283) • www.gtoaccess.com
!
WARNING
MOVING GATE
Can Cause Injury or Death
1. KEEP CLEAR! Gate may move at any time.
2. Do not allow children to operate gate or play in
gate area.
3. This gate is for vehicles only. Pedestrians must
use separate entrance.
Logo and warning labels (2) installed on each side of operator housing.
viii GTO 2000XL Instruction Manual © 120310
Gates That Open, LLC • Tallahassee, Florida USA
Technical Specifications
GTO/ACCESS SYSTEMS 2000XL AUTOMATIC GATE OPERATOR
DRIVE
• Low friction screw drive (linear actuator) rated for -5 ºF to +160 ºF (-21 ºC to +71 ºC). Use of heater bands on arm and
control box will enhance performance in extreme cold temperatures.
• Powered by a 12 V motor with integral case hardened steel gear reducer. Motor speed reduced to 260 rpm.
• Maximum opening arc of 110º. Approximate opening time (90º): 18-22 seconds, depending on weight of gate.
POWER
• The system is powered by a 12 Vdc, 7.0 Ah, sealed, rechargeable acid battery.
• Battery charge is maintained by a 120 Vac, 18 Vac output transformer rectified to 14.5 Vdc through the GTO control
board. Blade-style control board fuse is rated for 15 A.
NOTE: The transformer should not be directly connected to any battery. Do not replace fuses with higher ampere rated
fuses; doing so will void your warranty and may damage your control board.
• For optional solar charging see page 2.
CONTROL
• GTO microprocessor-based control board is set for pull-to-open gate installations. DIP switches can be adjusted to
accommodate an optional kit for push-to-open gates (see Accessory Catalog).
• Control board has temperature compensated circuits.
• A circuit on the control board regulates charging. “Sleep draw” is 15 mA; “active draw” is 2 to 5 A.
• Auto-memorization of digital transmitter code.
• GTO remote-mounted RF receiver tuned to 318 MHz.
• Operator length with push-pull tube fully retracted is 33 3/4”, mounting point to mounting point, arm stroke 15” max.
• Minimum gate length is 5 ft.
• Adjustable auto-close (3 to 120 seconds), and stall force potentiometers.
• Power terminal block accommodates a transformer or solar panels (not both).
• DIP switches simplify setup of gate operator.
• Accessory terminal block fully compatible with GTO push button controls, digital keypads, loops detectors, etc.
• Control board allows connection of safety edge sensors and photoelectric sensors.
• Audio entrapment alarm sounds if unit encounters an obstruction twice while opening or closing.
OPERATIONAL CAPACITY
• The Gate Capacity Chart shows approximate cycles, per day, you can expect from the GTO/ACCESS 2000XL Automatic
Gate Operator when powered with a transformer. Actual cycles may vary slightly depending upon the type and
condition of gate and installation.
PRO-SW2000XL Gate Capacity Chart
Gate Length
Estimated number of daily cycles, based on use with a transformer and one(1) 12 Volt battery.
16 ft.
14 ft.
12 ft.
up to10 ft.
135
145
155
165
50 lb.
120
130
140
150
100 lb.
105
115
125
135
150 lb.
N/R
100
110
120
200 lb.
Gate Weight
N/R
80
90
100
300 lb.
N/R
N/R
70
80
400 lb.
N/R
N/R
N/R
60
500 lb.
N/R - Not Recommended
NOTE: BALL BEARING HINGES SHOULD BE USED ON ALL GATES WEIGHING OVER 250 LB.
To determine the number of cycles the gate operator will perform using solar panels, please see the specifications listed
on page 2 or call (800) 543-1236 or (850) 575-4144 for more information.
* An operation cycle is one full opening and closing of the gate.
These specifications are subject to change without notice.
GTO 2000XL Instruction Manual © 120310
1
Before You Begin...
1. Determine Charging Option for Battery: Transformer OR Solar
NEVER USE TRANSFORMER AND SOLAR PANEL(S) AT THE SAME TIME.
It will damage the control board.
IMPORTANT:
• The 2000XL’s 12 volt battery must be charged by either connecting the transformer (included) or solar panel
kit [FM122] to the control board.
• The transformer is designed for indoor use. If the transformer can be plugged only into an outside electrical
outlet, a weatherproof cover/housing (available at local electrical supply stores) must be used.
• If your gate is more than 1000 ft. from an AC power source, you will need to use at least 5 watts solar charging
power to charge the battery [FM122]. Refer to the Solar Panel and Gate Activity chart below.
• All low voltage wire used with the GTO Gate Operator must be 16 gauge dual conductor, multi-stranded,
direct burial wire [RB509]. Do not run more than 1000 ft. of wire.
Solar Panel and Gate Activity Chart
The table and map
illustrate the maximum
number of gate cycles
to expect per day in a
particular area when
using from 5 to 30 watts
of solar charging power.
The figures shown are
for winter (minimum
sunlight).
Accessories connected to your system
will draw additional power from the
battery.
10 Watt Solar Panel [FM123]
5 Watt Solar Panel [FM122]
2 GTO 2000XL Instruction Manual © 120310
Winter Ratings for 12 V Single Gate
5 watts
10 watts
15 watts
20 watts
25 watts
30 watts
Zone 1
4
8
11
14
17
Zone 2
8
16
20
28
36
Zone 3
13
26
30
38
46
20
44
54
2. Check Direction of Gate Swing
The 2000XL kit is designed for PULL-TO-OPEN installations. PUSH-TO-OPEN installations require a Push-To-Open
Bracket [347IH]. Please refer to specific Push-To-Open Installation Information on page 22.
Your Property
Your Property
Pull-To-Open
(arm retracts to open)
Push-To-Open
(arm extends to open)
3. Prepare the Gate
• The gate must be plumb, level, and swing freely on its hinges. • The gate must move throughout its arc without binding or dragging on the ground. • Wheels must NOT be attached to the gate. • Gates over 250 lb. should have ball bearing hinges with grease fittings.
• Post must be secured in the ground with concrete (minimizes twist/flex when the operator is activated).
• Make sure there is a stable area for mounting the gate bracket (this may require the addition of a horizontal
or vertical cross member).
• We recommend you position the operator near the center-line of the gate to keep the gate from twisting and
flexing, and to avoid back-splash from rain.
Horizontal Cross Member
A
E
F
B
C
Vertical Cross Member
A – Level
B – Plumb
C – Free Swinging
D – Posts Secured in Concrete
E – Centerline Mounting
F – Good Working Hinges
D
GTO 2000XL Instruction Manual © 120310
3
4. 2000XL Parts List
®
ENER
E OP
E-Z GAT
Customer Support Card (1)
Operator Arm (1)
PRO2000ARMXL
6’ Power Cable
BRACKET BOX - HB100
Closed Position
Stop Plate (1)
Gate Bracket (1)
Post Bracket (2)
Post Pivot Bracket (1)
HARDWARE BAG - H101P
3/8" x 8" Bolt (4)
3/8" x 2-3/4" Bolt (2)
3/8" Lock Washer (7)
3/8" Nut (7)
3/8" x 2" Bolt (1)
5/16" Washer (1)
5/16" x 1-3/4" Bolt (1)
5/16" Nut (1)
3/8" x 1-1/2" Clevis Pin (2)
Hairpin Clip (2)
4 GTO 2000XL Instruction Manual © 120310
3/8" x 3/16" Bushing (2)
2" Screw (5)
8" Nylon Cable Tie (14)
3/8" Washer (9)
Battery (1)
! WARNING
Receiver (1)
GTO Transmitter(1)
Moving Gate Can Cause
Injury Or Death
1.
KEEP CLEAR! Gate may move at any time.
2.
Do not allow children to operate gate or
play in gate area.
3.
This gate is for vehicles only. Pedestrians
must use a separate entrance.
Warning Signs (2)
Transformer (1)
Control Box (1)
Drill
Drill Bit
5. Tools Needed
Center
Punch
Pen
• Power Drill
• Pliers
• Level
• Tape Measure
• Wire Strippers • Center Punch
• Open End Wrenches: 9/16” and 3/4”
• Drill Bits: 3/8” and 1/2”
• Hacksaw or Heavy Duty Bolt Cutters
• Small (Flat Head) Screwdriver
• Phillips Screwdriver
• C-Clamps: small, medium, and large
• Adjustable Wrench
• Extra person will be helpful
Pliers
Hack Saw
Hammer
Flat Head
Screwdriver
Open End Wrenches
Phillips Head
Screwdriver
Level
Clamps
Small, Medium, Large
Adjustable
Wrench
Wire
Stripper
Small
Flat Head
Tape
Measure
6. Materials You may Need for the Installation:
Depending on the type of gate and post, you may need some additional materials/hardware.
• Low voltage wire [RB509]. Length depends upon the distance between the transformer power supply and
the control box. (Page 14)
• If the gate is more than 1000’ away from an AC power source you will need to use at least one 5 watt Solar
Panel [FM122] to trickle charge the battery. (Page 2)
• PVC Conduit. (Page 6)
• The diameter of the post should be at least 6” in order to mount the post bracket. (Page 9) • Depending upon the diameter of the post, you may need longer bolts than those provided. Bolts should be
at least 1” longer than the diameter of the post. (Page 9)
• Metal plate for wooden posts. (Page 9)
• A horizontal or vertical cross member or mounting plate may be needed to mount the operator to the gate.
(Page 3)
• Some types of installations require U-Bolts. (Page 11)
• Surge protection for transformer. (Page 16)
• Weatherproof cover for transformer if installed outside. (Page 16)
• For push-to-open applications you must have PTO Bracket
[347IH). (Page 22)
GTO 2000XL Instruction Manual © 120310
5
Installation Overview for Pull-To-Open Gate
PUSH-TO-OPEN installation instructions begin on page 22.
Example of an installation on a chain link fence:
Receiver
Control Box with Battery
Gate Swings Evenly and Freely
Hung Firmly and Plumb
Horizontal Cross Member
Post Bracket Assembly
Single Gate Opener
120 Volt indoor
Transformer
Gate Bracket
(surge protector
not supplied)
Warning Sign
Power Cable
Closed Position Stop Plate
Fence Post Set in Concrete
Run 1000' (max.) of low
voltage wire to control
box from transformer
(wire not included).
PVC conduit (not included)
to protect wire from lawn
mowers and weed eaters.
IMPORTANT: To achieve the most efficient leverage for the gate opener and ensure long trouble free service, the
gate opener needs to be installed within the following parameters.
The diagrams below show the optimum positions for the gate opener arm in relation to the gate in the open and
closed positions. Be sure the position of the gate opener and brackets allows for 2" of clearance between the gate
and the opener in both the open and closed positions.
Gate in the
OPEN POSITION
Gate in the
CLOSED POSITION
2" minimum
Pinch Area
Pinch Area
2" minimum
If the gate post is larger than 6" the
Post Pivot Bracket can be removed
and the center hole of
the Post Bracket
can be the
mounting point
for the gate
opener.
Center hole of
post bracket
6 GTO 2000XL Instruction Manual © 120310
We recommend you position the opener near the centerline of the gate to keep the gate from twisting and flexing
and to avoid backsplash from rain water.
The Post Bracket Assembly
The position of the post bracket assembly determines the leverage and efficiency of the opener. The post bracket
assembly position also sets the clearance between the opener and the gate in the open and closed positions.
The post bracket works well for installations on round and square fence posts. Because the post bracket carries the
entire thrust of the active opener, bolts must completely penetrate the post.
On wood posts, place a metal plate
or washer (not supplied) between
the nuts and the post to prevent the
thrust of the opener from pulling
the bolts and washers out of the
wood.
The post pivot bracket may not be
necessary on posts larger than 6" in
diameter (see page 6). Fence posts
smaller than 6" in diameter or 6"
square should be made of metal
instead of wood to remain stable
while the opener is moving the gate.
Wooden Post
Metal Plate
Wooden Post
Metal Plate
Post Pivot
Bracket
Post
Bracket
Post
Bracket
Post
Bracket
Post Bracket
Assembly
Post
Pivot Bracket
Post
Pivot Bracket
Reinforcing Gates for the Gate Brackets
We recommend using a muffler clamp, wood, or metal, to reinforce thin-walled tube gates, or wood to reinforce
panel gates as shown. These reinforcement methods will prevent damage to the opener and gate. Additional
hardware may be needed depending on the installation.
Muffler Clamp
(not supplied)
Gate Bracket
Muffler Clamp for
Gate Bracket
Thin Walled
Tube Gate
Gate Bracket
Wood or Metal
Reinforcement
Wood or Metal
Reinforcement
(not supplied)
Gate
Bracket
1" x 6" Wood
Reinforcement
Panel
Gate
1" x 6"
Wood
Reinforcement
GTO 2000XL Instruction Manual © 120310
7
Install the Operator
Step 1
3/8" x 2" Bolt
Insert the 3/8" x 2" bolt through the center hole of the post
brackets and post pivot bracket as shown. Fasten a 3/8" lock
washer, 3/8" washer and 3/8" nut on the end of the bolt. DO
NOT overtighten the nut because the post pivot bracket will
have to be adjusted later.
Post Bracket
Post Pivot Bracket
Step 2
Attach post bracket assembly to the rear mount of the opener with
a clevis pin and a 3/8” washer. Secure the clevis pin with a hairpin
clip.
Post Bracket
Clevis Pin
3/8" Washer
Rear Mount
3/8" Lock Washer
Bushing
3/8" Nut
Operator
Front Mount
Hairpin Clip
Clevis Pin
Post Bracket Assembly
Gate Bracket
Step 3
Attach gate bracket to the front mount of the opener with a
clevis pin and a 3/8” bushing. Secure the clevis pin with a hairpin
clip.
Bushing
Hairpin Clip
Step 4
With the gate in the fully open position and the opener arm fully retracted, adjust the post bracket assembly and
gate bracket until the opener is level. While holding the opener level, use C-clamps to temporarily secure the post
bracket assembly and gate bracket to the post and gate.
Post Bracket Assembly
Level Operator
LEVEL hori
zontal cro
ss membe
Gate In Open Position
Fence Post
8 GTO 2000XL Instruction Manual © 120310
r
Gate Bracket
Step 5
After verifying that you have the best position for the
post pivot bracket in the open position, insert the
5/16" x 1-3/4" bolt through the aligned holes of the
post bracket and post pivot bracket to hold it in place.
Remove the clevis pin from the front mount and while
supporting the gate opener, swing the gate and gate
opener to the closed position.
Gate in the
CLOSED POSITION
2" minimum
Pinch Area
Be sure gate opener
and bracket don't bind.
Step 6
Be sure the position of the gate opener and brackets
allows for 2” of clearance between the gate and the
opener in both the open and closed positions, while
at the same time maintaining a maximum distance
of 13” from the end of the retracted opener arm to
the gate bracket with the gate in the closed position.
This mounting position will give the opener the most
efficient leverage point for operation and provides the
least possible pinch area.
Pinch Area
Gate in the
OPEN POSITION
2" minimum
Again, check the clearance and be sure that the gate
opener is not binding at the post pivot bracket.
Determine Best
Hole Alignment
to Achieve
2" Clearance
If you don't have the required clearance, or if the gate
opener is binding on the post pivot bracket, remove
the 5/16" x 1-3/4" bolt and readjust the post pivot
bracket.
5/16" x 13/4"
Bolt
Post Pivot
Bracket
TIP: Turn the post pivot bracket over for more hole alignment options. You
can also move the entire post bracket assembly to different positions on
the post.
Post Bracket
5/16"
Washer
5/16"
Nut
Step 7
When the post bracket assembly is in the optimum position, reattach the opener to the gate bracket (gate in the
open position); recheck the gate opener level; make sure the brackets are clamped securely.
Step 8
Mark reference points for bolt holes on the post through middle of post
bracket assembly slots. Mark reference points for bolt holes on the gate
cross member through middle of gate bracket slots. After marking your
reference points, remove the opener and brackets from the fence and
gate.
Mark gate post through
middle of bracket slots
and drill 3/8" holes
Gate In Open Position
LEVEL ho
rizontal cr
oss mem
Mark cross member through middle of
gate bracket slots and drill 3/8" holes
ber
Post Bracket
Assembly
GTO 2000XL Instruction Manual © 120310
9
Step 9
Drill 3/8" holes through post as marked. Fasten post bracket
assembly to the fence post using four 3/8" x 8" bolts, lock washers
and nuts. You must use bolts that completely penetrate the post.
EXAMPLES
TOP VIEW
Step 10
Round Metal Post
Drill 3/8" holes through the gate cross member as marked. Mount
gate bracket using two 3/8" x 2 3/4" bolts, lock washers, and nuts.
Square Metal Post
SIDE VIEW
NOTE: After the gate opener installation is complete and
operation of the opener system has been tested, you should
remove excess bolt length extending beyond the tightened nuts
with a hacksaw or bolt cutters.
Square Wood Post
Remove excess bolt length
with hacksaw or bolt cutters
Gate Bracket Mounting Examples
FRONT VIEW
SIDE VIEW
Round Wood Post
SIDE VIEW
FRONT VIEW
Mounting Plate
Created for
Decorative Gate
(required but not
supplied)
Round Tube & Chain Link Gate
Remove excess bolt length
with hacksaw or bolt cutters
Square Tube Gate
Attach Operator Arm
Attach the opener to the securely bolted post bracket assembly and gate bracket using clevis pins, bushings, and
hairpin clips, or optional Pin Lock [FM345] (page 30). Verify that the opener is level and adjust the post bracket
assembly, if necessary.
Post Bracket Assembly
bolted to gate post
Level Operator
LEVEL hori
zontal cro
ss membe
Gate Bracket bolted
to gate cross member
r
Clevis Pin, Bushing and Hairpin Clip
Gate Post
10 GTO 2000XL Instruction Manual © 120310
Gate In Open Position
Clevis Pin, Bushing,
and Hairpin Clip
Installation of the Closed Position Stop Plate
The 2000XL Gate Operator firmly holds the gate in the closed position using the closed position
stop plate. The closed position stop plate helps stabilize the gate leaf in the closed position. To
further enhance the stability and security of your gate, install the optional GTO Automatic Gate
Lock (see Accessory Catalog).
Step 1
Gate Hinge
Remove hairpin, clevis pin, and washer from front
mount and close the gate (remember to support
operator). Fasten the closed position stop plate to the
end of the gate frame on the gate centerline, but do
not tighten it completely. Slide the stop plate toward
the fence post until they touch (see illustration).
Once you have moved the stop plate to the correct
position, tighten its hardware completely.
Closed Position
Stop Plate
The gate must open
80º (min.) to 110º (max.)
Use the appropriate hardware for your type of
gate (use U-bolts if you have a tube or chain link
gate; wood or lag screws for wood gates; etc.). This
hardware is not provided.
SIDE VIEW
Step 2
Return the gate to the open position and reattach the
gate opener to the gate.
Gate Post
Closed Position Stop Plate mounted
on metal post with U-bolts.
Fence Post
TOP VIEW
GTO 2000XL Instruction Manual © 120310
11
Mount the Control Box and Receiver
Step 1
POWER
INPUTS
GTO 18 VOLT
TRANSFORMER
OR SOLAR
PWR
LOCK
AUX
RLY
1
CONTROL OUTPUTS
Mount the control box using the screws (provided) or another
secure mounting method. The control box must be mounted at least
3 feet above the ground to protect it from rain splash, snow, etc.,
and at least 3 feet from an AC power source to prevent electrical
interference.
GRN
4
5
ORG
6
25
BLK
GRN
BATT-
WHT
BLU
BRN
ORG
RED
BATT+
MASTER OPERATOR
BLK
COM
AUTO CLOSE TIME
120
1 2 3 4
ON DIP
MAX
STATUS
S3
S2
S4
LEARN RMT
LEARN
SLV LIMIT
ALM
LEARN
MAST LIMIT
BLK
RED
ON
ON
PUSH
SIMULT.
ON
ON
GRN
RECEIVER
GTO RCVR.
STALL FORCE
MIN
CLOSE
EDGE
OPEN
EDGE
OFF
OFF
SHADOW
OFF
EXIT
SOFT START OFF
WARNING
OFF
OPEN
PULL
SLV OPEN DLY.
SAFETY
MODE1
MODE2
COM
CYCLE
CONTROL INPUTS
Temporarily mount the receiver at this time. You will need to use
the transmitter (page 18) to check the range of the receiver before
permanently mounting it. You may have to try different locations
before permanently mounting the receiver. The receiver range can
vary from 50 to 100 feet depending upon weather, topography, and
external interference.
7
Step 2
FUSE
RED
PWR IN
3
BRN
2nd OPERATOR
BLU
Use mounting
holes and screws
provided to mount
control box to a
secure surface.
CHARGING
2
WHT
Mount the receiver:
• Ensuring a line-of-sight between transmitter and antenna.
• At least 3 feet away from AC voltage.
• As high as possible for optimum range.
• DO NOT mount receiver upside down.
• DO NOT mount receiver on metal fence or post (this will
decrease signal range). If attaching receiver to metal fence, you
should mount receiver on a piece of wood attached to the fence
(see illustration).
The receiver cable:
• Cable length is 10 ft. (receivers with longer cables are available
as special order items; call the GTO Sales Department).
• NEVER splice receiver cable!
• Run the receiver cable through PVC conduit to protect it from
damage.
• DO NOT run cable in conduit containing AC wiring.
FCC Regulation
This device complies with FCC rules Part 15. Operation is subject to the following conditions:
1.This device may not cause harmful interference.
2.This device must accept an interference that may cause undesired operation.
Transmitter distance may vary due to circumstances beyond our control. NOTE: The manufacturer is not
responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such
modifications could void the user’s authority to operate the equipment.
12 GTO 2000XL Instruction Manual © 120310
Connect Operator Power Cable
POWER
INPUTS
GTO 18 VOLT
TRANSFORMER
OR SOLAR
PWR
LOCK
AUX
RLY
1
CONTROL OUTPUTS
GRN
4
BRN
5
ORG
6
FUSE
7
25
RED
If the seven wires of the operator power cable are not already
striped, strip approximately 3/16” of insulation from each and
twist exposed wires tightly.
PWR IN
3
BLU
2nd OPERATOR
WHT
CHARGING
2
Loosen sealing nut on strain relief hub at bottom of control
box. Insert power cable into control box through strain relief.
Thread approximately 6” of the power cable into the control
box and retighten sealing nut until the power cable locks into
place.
Space for 12 Volt
battery (included).
BLK
Battery wires for
optional second battery.
GRN
BATT-
BLU
BRN
ORG
RED
BATT+
MASTER OPERATOR
WHT
BLK
COM
120
OFF
OFF
AUTO CLOSE TIME
OFF
SOFT START OFF
WARNING
OFF
OPEN
PULL
SLV OPEN DLY.
EXIT
ON DIP
MAX
STATUS
S3
S2
S4
LEARN RMT
LEARN
SLV LIMIT
ALM
LEARN
MAST LIMIT
BLK
RED
ON
ON
PUSH
SIMULT.
ON
ON
GRN
RECEIVER
GTO RCVR.
STALL FORCE
MIN
CLOSE
EDGE
OPEN
EDGE
CONTROL INPUTS
CYCLE
SAFETY
SHADOW
MODE1
MODE2
COM
1 2 3 4
Step 1
Space for optional
second 12 Volt battery
(see Accessory Catalog)
Strain Relief
Lock Nut
Strain Relief
Operator Power Cable
Hub
Sealing Nut
Step 2
Insert the stripped power cable wires into the appropriate terminals on the MASTER OPERATOR terminal
block. Insert the green wire into the GRN terminal, white wire into WHT, blue wire into BLUE, brown wire into BRN,
orange wire into ORG, red wire into RED, black wire into the BLK.
Tighten the set screws against the end of the wires.
NEVER splice wires together. Splicing permits corrosion and seriously degrades the wire’s ability to carry an
adequate current.
GRN
MASTER OPERATOR
WHT
BLU
BRN
ORG
RED
BLK
Power Cable from
Operator Arm
COM
COM
Correct
Wrong
Wrong
SAFETY
EXIT
SHADOW
CLOSE
EDGE
OPEN
EDGE
Exposed strands
of wire.
GRN
RECEIVER
Screwed into
wire insulation.
GTO RCVR.
Wire Terminal
Block
CONTROL INPUTS
CYCLE
BLK
RED
ALM
GTO 2000XL Instruction Manual © 120310
13
Connect the Transformer
IMPORTANT:
•
The transformer is designed and intended for indoor use. If the transformer can be plugged only into an
outside electrical outlet, a weatherproof cover/housing (available at local electrical supply stores) must
be used.
•
The only wire acceptable for use with GTO products is 16 gauge multi-stranded, low voltage, direct
burial wire [RB509]. This particular gauge enables the transformer to provide an adequate charge
through the control board to the battery at distances up to 1000 ft.
•
DO NOT use telephone wire or solid core wire; these types of wire may not deliver enough voltage for
your gate operator.
•
NEVER splice wires together. Splicing permits corrosion and seriously degrades the wire’s ability to carry
an adequate current.
•
NEVER USE TRANSFORMER AND SOLAR PANEL(S) AT THE SAME TIME! Doing so will
damage the control board.
• If your gate is more than 1000 ft. from an AC power source, you will need to use at least 5 watts solar
charging power [FM122/FM123] to charge the battery. Refer to the Solar Panels and Gate Activity
Chart on page 2.
Step 1
Make sure the control box power switch is OFF.
ON/OFF Switch
Step 2
Select the electrical outlet outlet into which you will plug the transformer. Measure the distance from this outlet
to the control box following the path where the wire will be laid (allow for an additional 6” to be pulled into the
control box). Make sure you have more than enough wire.
Step 3
POWER
INPUTS
GTO 18 VOLT
TRANSFORMER
OR SOLAR
PWR
LOCK
AUX
RLY
1
CONTROL OUTPUTS
Lay the measured length of low voltage wire in a 6” deep trench
following a path from the selected electrical outlet to the control
box. Wires coming up from the ground should be run through PVC
conduit to protect them from lawn mower blades, weed eaters, and
grazing animals. Bury the wire in the trench.
GRN
4
5
ORG
6
25
7
BLK
GRN
BATT-
BRN
ORG
RED
BATT+
MASTER OPERATOR
WHT
BLU
BLK
COM
AUTO CLOSE TIME
120
OFF
OFF
1 2 3 4
ON DIP
ON
ON
MAX
STATUS
S3
S2
LEARN RMT
S4
LEARN
SLV LIMIT
ALM
LEARN
MAST LIMIT
BLK
RED
ON
ON
PUSH
SIMULT.
GRN
RECEIVER
GTO RCVR.
STALL FORCE
MIN
CLOSE
EDGE
OPEN
EDGE
OFF
EXIT
SHADOW
SOFT START OFF
WARNING
OFF
OPEN
PULL
SLV OPEN DLY.
CYCLE
SAFETY
MODE1
MODE2
COM
CONTROL INPUTS
Feed the low voltage wires upward through the strain relief opening
on the lower left of the control box. Pull 6” to 8” of wire into the
control box.
FUSE
RED
PWR IN
3
BRN
2nd OPERATOR
BLU
CHARGING
2
WHT
Step 4
Low Voltage Wire
from Transformer
Power Cable from
Operator Arm
PVC Pipe
14 GTO 2000XL Instruction Manual © 120310
Step 5
RED
BLACK
POWER
INPUT
GTO 18 VOLT
TRANSF. OR
SOLAR PANEL
PWR
AUX
RLY
1
Insert one transformer wire into an 18
VAC OR SOLAR terminal. Insert the other
transformer wire into the remaining 18 VAC
OR SOLAR terminal. The transformer wires
can be connected to the 18 VAC OR SOLAR
terminals regardless of color/polarity.
CONTROL OUTPUTS
Low Voltage Wire
from AC Transformer
or Solar Panel
LOCK
Strip 3/16” off the ends of the low voltage
wire and twist tightly. Attach these ends to
the 18 VAC OR SOLAR terminals located on
the POWER INPUT terminal block. Be certain
not to let the exposed wires touch each
other!
GRN
2
3
BLU
4
BRN
5
ORG
6
Tighten set screws against exposed end of
wires.
RED
2ND OPERATOR
WHT
7
BLK
GRN
BLU
BRN
ORG
RED
Power Cable
from Master Arm
MASTER OPERATOR
WHT
BLK
COM
Step 6
At the transformer, strip 1/2” of insulation from the ends of the low
voltage wire. Attach wires to the transformer terminals. Make sure
the exposed wires do not touch each other!
DO NOT PLUG THE TRANSFORMER INTO AN OUTLET DURING
THIS STEP! THE TRANSFORMER MUST ONLY BE PLUGGED INTO
AN OUTLET DURING STEP 3 (page 16)!
Connect Battery
Step 1
Make sure the control box power switch is OFF. Remove the control box cover and
slide the battery into position (terminals to the right).
ON/OFF Switch
GTO 2000XL Instruction Manual © 120310
15
Step 2
IMPORTANT: Connect the BLACK battery wire to the NEGATIVE (–)
battery terminal. Connect the RED battery wire to the POSITIVE (+)
terminal. Reverse connection of wires will damage the control
board.
BLACK
RED
Class 2
Transformer
BLACK wire to NEGATIVE (–) terminal
RED wire to POSITIVE (+) terminal
Step 3
Plug the transformer into the electrical outlet. (Use of a surge protector
with the transformer is strongly recommended.) IMPORTANT: This is
a class II indoor transformer; if using transformer outdoors be sure to
enclose it in a weatherproof case.
The battery should have a full charge before you program the Control Board. Please refer to the
Battery/Power Troubleshooting section on page 27 to determine if the battery is connected properly and fully
charged.
If the battery has a full charge and the gate fails to move you may need to adjust the STALL FORCE page 17.
Program Control Board
Set the Closed Position Limit (for Pull-To-Open Applications)
NOTE: For heavier gates you may need to increase the stall force (see pg 17). If the gate still does not open or close
to the limits you have set, check to ensure that the gate installation was performed correctly according to the
guidelines set forth on page 6. If the transmitter does not activate the gate operator you may have to reset the
transmitter code (see pg 18). If you have a Push-To-Open Installation, see page 22.
Step 1:
TURN CONTROL BOX ON. Your 2000XL has two Limit Settings:
OPEN Limit setting: (Gate in the OPEN POSITION/arm fully retracted). The OPEN limit can only be adjusted by
moving the gate bracket.
CLOSED Limit setting: (Gate in the CLOSED POSITION). To achieve optimum closed position, you are required
to complete the following:
Step 2
Confirm that the power switch is in the ON position and the gate is in the OPEN POSITION (arm fully retracted).
Step 3
Activate your operator by pressing the transmitter button. Your gate should now be moving from the fully open
position toward the closed position. Prepare to STOP the gate by pressing the entry transmitter button again when
the gate reaches the desired closed position. This step may be repeated until desired closed position is achieved.
16 GTO 2000XL Instruction Manual © 120310
Step 4
With the gate in the desired closed position
PRESS & HOLD the “LEARN MAST LIMIT”
button on the control board for 5 seconds.
Step 5
AUTO CLOSE TIME
gate to close.
MODE1
MODE2
LEARN RMT
120
OFF
OFF
PULL
DLY.
OFF
OFF
MIN
MAX
ON DIP
START
WARNING
TESTING YOUR CLOSED LIMIT SETTING:
OPEN
Press your entry transmitter and allow yourSLV OPEN
STATUS
1 2 3 4
Press the transmitter button and allow the
gate to return to the fully open position (arm
fully retracted). The gate closed position
limit is now programmed.
SOFT
STALL FORCE
ON
ON
PUSH
SIMULT.
S3
LEARN
MAST LIMIT
ON
ON
CLEARING THE PROGRAMMED CLOSED
LIMIT SETTING:
If you make a mistake and set the limit at
the wrong position: press your transmitter
to return the gate to the fully open position,
then press and hold the “LEARN MAST LIMIT”
button for 5 seconds. This will clear the
memory for the closed limit position. Repeat
Steps 3 and 4.
S2
LEARN
2ND LIMIT
S4
Learn Master Limit
Button
Adjust the Stall Force
Setting
The Stall Force potentiometer on the control
board controls the amount of force the
operator will apply to an obstruction for two
(2) seconds before it automatically stops
and reverses direction.
STALL FORCE
MIN
MAX
SOFT START
WARNING
OPEN
2ND OPEN
MODE1
MODE2
120
OFF
OFF
PULL
DLY.
OFF
OFF
MIN
MAX
ON DIP
The Stall Force potentiometer on the control
board operates like a volume control on a
radio. Use a small flat blade screwdriver to
adjust the potentiometer. Adjust the stall
force from the MIN position until the gate
operates smoothly without obstructing
from its own weight or wind conditions.
OFF
STALL FORCE
1 2 3 4
IMPORTANT: For safety reasons the stall
force setting will need to be adjusted for
your particular application.
AUTO CLOSE TIME
ON
ON
PUSH
SIMULT.
ON
ON
NOTE: you may need to increase the stall
force in cold temperatures due to increased
resistance from gate hinges.
GTO 2000XL Instruction Manual © 120310
17
Set Auto Close Time
The Auto-Close Time potentiometer controls
the Auto-Close feature, and determines how
long the gate will remain open (at the fully
open position) before it begins to close. The
settings for this feature are OFF, or from 3 to
120 seconds.
STALL FORCE
STATUS
LEARN RMT
OFF
120
MODE1
MODE2
Auto Close Time
Potentiometer
OFF
OFF
PULL
DLY.
MAX
ON DIP
SOFT START
WARNING
OPEN
2ND OPEN
MIN
1 2 3 4
Adjust the Auto-Close potientiometer by
using a small flat blade screwdriver.
AUTO CLOSE TIME
OFF
OFF
ON
ON
PUSH
SIMULT.
S3
LEARN
MAST LIMIT
ON
ON
S2
LEARN
2ND LIMIT
S4
Program Your Personal
Transmitter Setting
All GTO transmitters are set to a standard code at the factory
and are ready to operate your gate operator. For your safety and
security, we strongly recommend that you replace the factory
setting with your own personal setting. Follow the directions
below:
LE
D
NOTE: If you have multiple transmitters, you should adjust all of
them at this time (refer to individual transmitter instructions for
details). [RB741/RB742/RB743].
0
–
+ 1
2
3
4
5
A
A 2
LK
AL
3S
IN
E
BA 12
TT
ER
6
7
8
9
EC
E
V
Y
Step 1
Use a small phillips head screw driver to remove the transmitter
cover.
1 2 3 4 5 6 7 8 9
+
0
Step 2.
Set the transmitter DIP switches using a small screwdriver. There
are nine (9) transmitter DIP switches; each can be placed in three
different positions (+, 0, –). DO NOT set all the switches in the same
position, such as all +, all 0, or all –. Once the DIP switches have
been reset, replace and close the access cover.
ECE
WARNING: No other adjustments should be made inside the
transmitter.
Step 3.
AUTO CLOSE TIME
STALL FORCE
Program the new setting into the control board:
STATUS
A. Press and hold transmitter button.
LEARN RMT
120
C. Release transmitter button. The new code is stored in
control board memory.
MODE1
MODE2
D. Release the LEARN RMT (Learn Remote) button.
NOTE: If you have purchased additional transmitters, program the
settings for all at this time.
NOW TEST RECEIVER BEFORE PERMANENTLY MOUNTING IT
(See page 12).
18 GTO 2000XL Instruction Manual © 120310
OFF
OFF
PULL
DLY.
OFF
OFF
MAX
ON DIP
SOFT START
WARNING
OPEN
SLV OPEN
1 2 3 4
B. Press and hold the LEARN RMT (Learn Remote) button on
the control board until the alarm sounds.
MIN
ON
ON
PUSH
SIMULT.
ON
ON
S3
LEARN
MAST LIMIT
S2
LEARN
2ND LIMIT
S4
Learn Remote
Button
Control Board Settings
DIP Switches
Main DIP Switch Settings (MODES)
ON
DIP Switch #2: Warning Buzzer
OFF
The Soft Start/Stop feature slowly
starts the gate as it begins to open
and slows the gate as it comes to the
closed position. This saves wear and
tear on the gate and gate operator
system.
DIP
OFF– Soft start disabled.
ON
ON– Soft start enabled (factory
preset).
1 2 3 4
DIP Switch #1: Soft Start/Stop
AUTO CLOSE TIME
STALL FORCE
ON– Buzzer warning enabled (factory
preset).
STATUS
OFF– Buzzer warning disabled.
OFF
OFF
PULL
DLY.
OFF
OFF
MIN
MAX
ON DIP
SOFT START
WARNING
OPEN
2ND OPEN
MODE1
MODE2
120
1 2 3 4
The Warning Buzzer alerts you when
the gate operator is beginning to
open or close the gate. It sounds for
the first 2 seconds in each direction.
It also sounds a warning when the
gate obstructs two times in one cycle.
Switching this to OFF only disables
the open and close warning not the
obstruction warning.
LEARN RMT
OFF
ON
ON
PUSH
SIMULT.
ON
ON
S3
LEARN
MAST LIMIT
S2
LEARN
2ND LIMIT
S4
DIP Switch #3: Push/Pull-To-Open
ON: Push-To-Open.
OFF: Pull-To-Open (factory preset).
If your gate opens into the property
the DIP Switch is set to the OFF
position (factory setting). If your gate
opens out from the property the DIP
Switch must be set to the ON position.
NOTE: if you have a Push-to-Open
gate application you will need a PushTo-Open bracket (see Push-To-Open
Instructions on page 22).
DIP Switch #4: Dual Operation
ON– Second opens simultaneously
with master.
OFF– Second opens after master
(factory preset).
Note: Not applicable for single gate
operator.
GTO 2000XL Instruction Manual © 120310
19
Connnecting Accessories
Input Connections
• All control inputs are dry-contact, normally open, inputs. DO NOT apply external voltage sources to these
inputs.
• All inputs are connected with respect to COMMON terminal.
• The status LED will blink once when any input is activated.
1COM: Circuit common (reference for all
logic input)
• Two (2) terminals to provide extra
common connection point.
BLK
2CYCLE/CLOSE: (Typically for use with
push button or hard-wired keypad)
• Each activation at this input will cycle
the operation as follows:
OPEN–STOP–CLOSE–STOP–OPEN
1
2
CYCLE
3SAFETY: (Typically for use with photo
beam device, loop detector or other
non-contact sensors)
• Activation of this input while the gate
is closing will cause the gate to stop
and return to the opened position.
• Activation of this input while the gate
is opening has no effect (gate will
continue to open).
• Activation of this input while gate is
idle will prevent gate from closing.
3
SAFETY
4
EXIT
5
SHADOW
6
CLOSE
EDGE
OPEN
EDGE
COM
CONTROL INPUTS
7
GRN
RECEIVER
GTO RCVR.
BLK
RED
ALM
4EXIT/OPEN: (Typically for use with exit
loop or wand)
• Activation of this input will open the
gate if it’s not already at the open
position
• Activation of this input while at open
limit will restart the auto close time (if
enabled).
COM
5 SHADOW LOOP: (Typically for use with loop detector)
• This input is only monitored when the gate is at the fully open position. At any other position, activation of
this input has no effect on gate operation.
• Activation of this input while gate at the fully open position will prevent gate from closing.
6 CLOSE EDGE: (Typically for use with safety edge device)
• Activation of this input while the gate is closing will cause the gate to stop and reverse direction for
approximately 2 seconds.
• Activation of this input while the gate is opening has no effect (gate will continue to open).
• Activation of this input while gate is idle will prevent gate from closing.
7 OPEN EDGE: (Typically for use with safety edge device)
• Activation of this input while the gate is opening will cause the gate to stop and reverse direction for
approximately 2 seconds.
• Activation of this input while the gate is closing has no effect (gate will continue to close).
• Activation of this input while gate is idle will prevent gate from opening.
20 GTO 2000XL Instruction Manual © 120310
Wiring Accessories
CONTROL OUTPUTS
RECEIVER
6
7
GTO RCVR.
6
7
Automatic Gate Lock (FM144 & FM142)
COM
ALM
RED
5
COM
4
GRN
3
BLK
BLK
2
BRN
CLOSE
EDGE
ORG
OPEN
EDGE
RED
71
BLU
6
SHADOW
5
WHT
EXIT
4
GRN
SAFETY
3
CYCLE
2
RED
COM
BLK
COM
WHT
BLU
GRN
1
7
CONTROL INPUTS
CONTROL
INPUTS
MASTER
OPERATOR
CYCLE
AUX
2ND OPERATOR
RLYMASTER OPERATOR
GRN
BRN
GTO 18 VOLT
TRANSF. OR
SOLAR PANEL
PWR
BLK
6
RED
5
ORG
4
BLU
3
WHT
2
LOCK
BRN
WHT
ORG
BLU
RED
BRN
BLK
ORG
POWER
INPUT
2ND OPERATOR
According to
Application
1
Edge Sensor
1
2
Push Button Control (RB101)
3
1
Photo Beams (R4222)
4
1
1
4
GHI
7
PRS
2
ABC
5
JKL
8
TUV
0
Vehicle Sensor (FM139)
3
DEF
6
MNO
Refer to Vehicle Sensor
manual for additional
connections.
9
WXY
1
2
Digital Keypad (F310)
NOTE: There may be additional connection options for
applications that are not illustrated here.
Refer to accessory manuals for details.
Connecting Other Auxiliary Devices (Sirens, Lights, etc.)
• These 2 terminals are normally open “dry-contact” (no voltage) relay ouput.
• Relay is closed when the gate is in motion; Relay is open when the gate is not in motion.
• These 2 terminals maximum rating is 24Vdc, 1 Amp.
AUX
RLY
GTO 2000XL Instruction Manual © 120310
21
Push-To-Open Installation Information
Swinging gates shall not open into public access areas!
A “Push-to-Open” gate opens out from the property (operator arm extends to open the gate). A Push-To-Open
installation requires the purchase of a Push-To-Open Bracket [347IH].
In a Push-To-Open installation the operator is installed while the gate is in the CLOSED POSITION.
Install the Operator
A
Gate In Closed Position
Follow directions for installing the 2000XL
beginning on page 7. The Push-To-Open
installation differs from the Pull-To-Open
installation in the following ways:
Level Operator
LEVEL horiz
ontal cros
sm
1. In a Push-To-Open installation, the arm
fully extends to open the gate, and it
fully retracts to close the gate. (C)
ember
Clevis Pin, Bushing and Hairpin Clip
2. You will install the operator while the
gate is in the CLOSED POSITION (arm
fully retracted). (A)
Gate Post
3. You must use the Push-to-Open Post Pivot Bracket
Bracket assembly(B).
[347IH] in the Post
4. IMPORTANT: While determining the mounting point for the post pivot
bracket assembly be sure that the position allows for 2” clearance between
the gate and the operator in both the open and closed positions (see
diagram below). This clearance will give the operator the most efficient
leverage point for opening and closing the gate and more importantly
provides the least possible pinch area. (C)
3/8" x 2" Bolt
B
Post Bracket
Push-To-Open
Pivot Bracket
Post Bracket
C
3/8" Washer
3/8" Lock Washer
3/8" Nut
Gate in the
OPEN POSITION
Pinch Area
2" minimum
2" minimum
Gate in the
CLOSED POSITION
Pinch Area
22 GTO 2000XL Instruction Manual © 120310
*The Troubleshooting Wizard
has detailed information on
Push-To-Open installations.
2
3
4
OFF
ON
ON
MAX
OFF
OFF
MIN
120
1 2 3 4
MODE1
MODE2
1
ON DIP
OFF
ON
AUTO CLOSE TIME
ON
SOFT START OFF
WARNING
OFF
OPEN
PULL
SLV
2ND OPEN
OPEN DLY.
DLY.
STALL FORCE
Make sure the control box power switch is OFF. Use a small
screwdriver to move the Number 3 DIP switch from the factory
setting (OFF / Pull-To-Open) to ON for Push-To-Open. Turn power
switch ON. The control board is now configured to push the gate
open.
ON
ON
PUSH
SIMULT.
Set Control Board for Push-To-Open
DIP#3
ON: Push-to-open operation.
OFF: Pull-to-open operation (factory setting).
Setting the Open Position Limit (PushTo-Open Installations)
Step 1
Confirm that the power switch is in the ON position, and the gate is in the CLOSED POSITION.
Step 2
Activate your operator by pressing the entry transmitter button. Your gate should now be moving from the closed
position toward the open position. Prepare to STOP gate by pressing the entry transmitter button again when the
gate reaches the desired open position. This step may be repeated until desired open position is achieved. Once
the desired OPEN position has been achieved, proceed to Step 3.
Step 3
With the gate in the desired open position PRESS & HOLD the “LEARN MAST LIMIT” button on the control board for
2 seconds.
Step 4
Press the transmitter button and allow
the gate to return to the closed position. AUTO CLOSE TIME
YOUR GATE’S OPEN POSITION LIMIT IS NOW
PROGRAMMED.
STATUS
LEARN RMT
MIN
MODE2
CLEARING PROGRAMMED OPEN LIMIT
SETTING:
If you make a mistake and set the limit at the
wrong position – press your transmitter to
return the gate to the fully closed position,
then press and hold the “LEARN MAST LIMIT”
button for 2 seconds. This will clear the
memory for the open limit position. Follow
steps one (1) to four (4) again.
OFF
MAX
ON DIP
1 2 3 4
TESTING YOUR OPEN LIMIT SETTING:
120
Press your entry transmitter and allow your
gate to open. If the OPEN position is not SOFT START OFF
OFF
correct or needs to be changed, you will WARNING
OPEN
PULL
need to CLEAR your OPEN LIMIT settings and
SLV OPEN DLY.
follow steps one (1) to four (4) again.
MODE1
OFF
STALL FORCE
ON
ON
PUSH
SIMULT.
ON
ON
S3
LEARN
MAST LIMIT
S2
LEARN
2ND LIMIT
S4
Learn Master Limit
Button
GTO 2000XL Instruction Manual © 120310
23
Column Installation
If this operator will be used with gates that are mounted on masonry, brick, or rock (etc.) columns, read the
following carefully before proceeding
A. The simplest solution is to install the operator in a push-to-open configuration. The minimum clearance is
easier to achieve and clearance is no longer a problem, since the operator will be pushing the gate away from
the column instead of pulling it toward the column. It is recommended that you place a steel plate between
the operator mounting brackets and masonry surface for additional strength.
B. If a push-to-open installation is impossible due to traffic hazards, terrain, etc., another option is to re-hang the
gate. You may hang it on a post, either in the center of the column or at the back corner, or move the gate to
the back corner of the column.
C. The most difficult solution is to cut a notch in the column to accommodate the operator and power cable.
This job is NOT for the inexperienced!*
Hinge
Gate
Column
Pivot Bracket
B
Column Mount Example
(A + B can not exceed 15 inches)
Example: If A is 6" then B cannot exceed 9"
A
*The Troubleshooting Wizard has detailed information on
column mounting.
24 GTO 2000XL Instruction Manual © 120310
Troubleshooting Guide
VOLTAGE RATINGS
18 Vac Transformer......................................................................................18.0 to 22.0 Vac, 2200 mA
5 W Solar panel (single).............................................................................18.0 to 22.0 Vdc, 300 mA
* measure voltage at panel and control box.
12 V, 7 amp hour Battery...........................................................................12.5 to 13.5 Vdc 7.0 Ah
or Two 12V, 7 amp hour Batteries if using solar power
*measure voltage at battery terminals with battery disconnected
Charging circuit ...........................................................................................12.0 to 14.8 Vdc
*measure voltage at battery terminals with battery connected
If your gate operator does not function properly after it is installed, use this guide before calling the GTO
Service Department.
Generation 3 Audible Feedback
SYMPTOM
1 short beep upon
activation
DIAGNOSIS
Blown Fuse
Low or Bad Battery
Loose Battery
Connection
CHECK:
1 short beep upon
power up
• Normal Operation
Continuous
Uninterrupted
Alarm
Circuit Board
Powered Up &
Ready
Circuit Board
Senses an
Obstruction
1 beep with 10
seconds off
Low Battery
Condition
• Fuses
• Battery Harness Connections
• Battery Under Load
1 beep then 2
beeps
Master Motor
Terminals Shorted
• Connections to Master Inputs
• Master Arm Power Cable
• Motor
• Circuit Board
1 beep with 2
seconds off
Master Arm Limit
Switch Error
• Connections to Master Inputs
• Master Arm Power Cable
• Master Input ORG & GRN, BRN & GRN voltage with wires
disconnected. 11VDC across each terminal.
3 beeps with 2
seconds off
Master Arm Rev
Counter Error
• Connections to Master Inputs
• Master Arm Power Cable
• Rev Counter
• Fuse
• Battery Under Load
• Battery Harness Connections
• Path of Gate
• Gate for Level and Plumb
• Stall Force Adjustment
• Disconnect Safety Devices
• Rev Counter
GTO 2000XL Instruction Manual © 120310
25
Generation 3 Visual Feedback
SYMPTOM
DIAGNOSIS
Status (clear)1 blink Cycle Terminal
Shorted
CHECK:
• Disconnect the push button, keypad, intercom keypad, or
any other accessory wired to this terminal.
• Try the remote. If the remote works, then the problem is
the accessory.
Status (clear) 2
blinks
Safety Terminal
Shorted
• Disconnect the loop detector, photo beam, or any other
accessory wired to this terminal.
• Try the remote. If the remote works, the problem is the
accessory.
Status (clear) 3
blinks
Exit Terminal
Shorted
• Disconnect exit wand, loop detector, photo beam, or any
other accessory wired to this terminal.
• Try remote. If the remote works, the problem is the
accessory.
Status (clear) 4
blinks
Shadow Terminal
Shorted
• Disconnect the loop detector, photo beam, or any other
accessory wired to this terminal.
• Try remote. If the remote works, the problem is the
accessory.
Status (clear) 5
blinks
Close Edge
Terminal Shorted
• Disconnect the edge sensor, photo beam, or any other
accessory wired to this terminal.
• Try the remote. If the remote works, the problem is the
accessory.
Status (clear) 6
blinks
Open Edge
Terminal Shorted
• Disconnect edge sensor, photo beam, or any other
accessory wired to this terminal.
• Try the remote. If the remote works, the problem is the
accessory.
RF (yellow) Flickers
Receiving 318 MHz
RF
• Normal operation when remote or wireless keypad is used.
RF (yellow)OFF
No 318 MHz RF
Received
• Battery in Remote
• Program Remote
• Antenna Receiver Connections
• Antenna Receiver
Power (green)
ON
AC or Solar Power
Present
• Normal Operation
26 GTO 2000XL Instruction Manual © 120310
Battery/Power Troubleshooting
RED LED
AUTO CLOSE TIME
FUSE
15
STALL FORCE
STATUS
BATT+
CHARGING
LEARN RMT
BATT-
OFF
120
MODE1
MODE2
MAX
ON
POWER IN
MIN
1 2 3 4
SOFT START OFF
WARNING
OFF
OPEN
PULL
2ND OPEN DLY.
OFF
OFF
ON
ON
PUSH
SIMULT.
S3
LEARN
MAST LIMIT
ON
ON
S2
CHARGING
LEARN
2ND LIMIT
POWER IN
S4
DIAG
PORT
GREEN LED
CONTROL OUTPUTS
RECEIVER
2ND OPERATOR
POWER IN LED
ON
ON
ON
OFF
OFF
OFF
CHARGING LED
Steady ON
Blinking
OFF
OFF
Blinking
Steady ON
BLK
RED
GRN
EXIT
ALM
CLOSE
EDGE
OPEN
EDGE
SHADOW
COM
CYCLE
SAFETY
BLK
COM
RED
ORG
BRN
7
BLU
6
GRN
5
BLK
4
RED
3
ORG
2
GRN
1
GTO 18 VOLT
TRANSF. OR
SOLAR PANEL
CONTROL INPUTS
MASTER OPERATOR
WHT
AUX
RLY
BRN
PWR
BLU
LOCK
WHT
POWER
INPUT
GTO RCVR.
Battery Charging
Battery Fully Charged
Bad Charger
No AC/Solar Power
Low Battery
Bad Charger
Repair Service
If your GTO 2000XL Gate Operator is not operating properly, please follow the steps below:
1. First use the procedures found in the Troubleshooting Guide (see page 25).
2. Use the 24/7 Troubleshooting Wizard at http://support.gtoinc.com.
3. If you are unable to solve the problem, call the GTO Service Department at (800) 543-1236, or (850) 5754144. Refer to the serial number (located on the right side of the control box) and date of purchase when
calling for assistance.
4. If repair or replacement of your gate operator is necessary, the Service Department will assign a Return
Goods Authorization (RGA) number to you.
5. Securely pack the component(s) authorized for return to the factory. Include a copy of your sales reciept
for the purchase of the product(s). Write the RGA number issued to you on the outside of the package in
LARGE BOLD PRINT.
Ship the package(s) freight prepaid to: GTO, 3121 Hartsfield Road, Tallahassee, Florida, USA 32303.
NOTE: Products returned to GTO without a Return Goods Authorization (RGA) number in LARGE
BOLD PRINT on the outside of the package WILL NOT be accepted. Also, items returned to GTO
freight collect WILL NOT be accepted.
GTO Technical Service and Installation Assistance
8:00am–7:00pm • Monday–Friday (EST)
Toll Free Support: 800-543-1236 • Local Support: 850-574-4144 • Fax: 850-575-8950
24/7 Troubleshooting Wizard: http://support.gtoinc.com
GTO 2000XL Instruction Manual © 120310
27
Accessories for 2000XL
Please visit www.gtoaccess.com for photos and detailed descriptions of GTO
Accessories. Or call 1-800-543-GATE (4283).
POWERING ACCESSORIES
Low Voltage Wire [RB509]
The 16 gauge, multi-stranded, dual conductor low voltage Wire is for connecting the AC
powered transformer, solar panel or wired accessories to the system’s control board. This
specially designed wire is UV treated, PVC coated, and ready for direct burial.
Solar Panel Kits [FM122/FM123]
If your gate operator is more than 1000 ft. away from an AC power outlet, you can choose to
maintain the battery charge with the GTO Solar Panel Kit.
• 10 Watt Solar Panel Charging Kit [FM123]
• 5 Watt Solar Panel Charging Kit [FM122]
Additional/Replacement Battery [RB500]
For additional battery power or replacement.
“FROM VEHICLE” ENTRY AND EXIT ACCESSORIES
Transmitters [RB741/RB742/RB743]
Purchase an additional transmitter for each vehicle in your family. The Two-Button
Transmitter can be programmed to operate both your gate operator and a garage door
opener using the Universal Receiver. Or it can be programmed to open two gate operator
systems.
• Single Button Transmitter [RB741]
• Dual Button Transmitter [RB742]
• Three Button Transmitter [RB743]
Universal Receiver [RB709U-NB]
The Universal Antenna Receiver gives you the ability to use one remote to activate your
gate operator and your garage door opener. Connects to any brand garage door opener. Up
to 100 ft. range.
1
4
2
ABC
5
GHI
JKL
7
PRS
8
TUV
3
DEF
6
MNO
Digital Keypad [F310]
Allow friends access to your property using an entry code that you provide. Program up to
25 entry codes for added security. Powered by three “AA” batteries (not included).
9
WXY
0
28 GTO 2000XL Instruction Manual © 120310
Ans
wer
Per Grant
mis
sio
n
Ke
Ba ypa
tt d
Low
POW
ER
Residential Wireless Entry Intercom [F3100MBC]
Designed for added security to your automated gate with the ability to “speak to” and
“screen” visitors safely from inside your home. Ideal for securing gate entrances while
providing controlled access.
DV
9V
Gooseneck Pedestal [F100/F110]
Designed to mount digital keypads, wireless intercom systems, and other access control
devices for your gate automation system.
“HANDS FREE” ENTRY & EXIT ACCESSORIES
Driveway Vehicle Sensor [FM139]
Automatically activates gate operator “Hands-Free” when a vehicle exits the property.
Electromagnetic sensor detects vehicles in motion.
• 50 ft. [FM139]
• 100 ft. [FM140]
• 150 ft. [FM141]
Wireless Vehicle Sensor [R4500]
Automatically activates gate operator “Hands-Free” when a vehicle exits the property. 100 ft.
range between transmitter and receiver. Easy installation.
LOCKING & SECURITY ACCESSORIES
ATIC
OM CK ®
AUTE LOLO
CK
GASETCURITY
IC
ON
TR
ELEC
1
4
GHI
7
PRS
2
ABC
5
JKL
8
TUV
0
3
DEF
6
MNO
®
9
WXY
SEC
URITY
, Inc.
GATE
LOC
K
Automatic Gate Lock [FM144/FM142]
The #1 Accessory For Swing Gate Operators! Designed for added security in conjunction
with GTO Automatic Gate Operators. The gate lock unlocks and locks automatically when
the gate opens and closes. The perfect solution for high wind conditions.
Bulldog Pedestrian Gate Lock [FM145]
Designed to mount on horizontal swing “walk through” wood, chain link, and metal
pedestrian gates opening in or out. Ideal for securing pools, condominiums, schools and
any pedestrian gate.
Wireless Driveway Alarm [R4450].
This device alerts you of vehicles entering your driveway (with or without an automated
gate). The indoor base station signals you with a door chime when a vehicle passes the
driveway sensor.
ADDITIONAL ACCESSORIES
GTO 2000XL Instruction Manual © 120310
29
Photo Beams [R4222]
Primary “through beam” photo beam device. Provides “non-contact” entrapment protection.
Pin Lock [FM345]
Use as a substitute for the clevis pin at the front mount of the PRO-SW2000XL to prevent
theft of the operator.
• Pin Lock 10-pack: ten Pin Locks keyed alike [FM345KA].
Push Button Control [RB10]
Wire this unlit push button directly to your gate operator for simple open/close/stop
operation from up to 1000 ft. away. Use 16 gauge low-voltage wire.
Replacement Transformer [RB570]
Standard 18 volt, 2200 mA AC transformer included with the 2000XL to maintain battery
charge.
HARDWARE ACCESSORIES
Push To Open Brackets [347IH]
Required when the 2000XL must push a gate open (arm extends to open), such as away
from a sloping driveway or where space prevents gate from opening into the property (pull
to open). Order two brackets for a dual swing gate installation.
Column Mount Lock Receiver [433IH]
For use with the Automatic Gate Lock or Bulldog Pedestrian Gate Lock when mounting on
brick columns or applications with limited space.
30 GTO 2000XL Instruction Manual © 120310
ACCESS
SYSTEMS
PROFESSIONAL RESIDENTIAL
3121 Hartsfield Road • Tallahassee, Florida, USA 32303
(850) 575-0176 • Fax (850) 575-8912
Web site www.gtoaccess.com
24/7 Troubleshooting Wizard: http://support.gtoinc.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement