GPM GPH

Add to My manuals
4 Pages

advertisement

GPM GPH | Manualzz

The Champion Series

Constant Temperature by AMTROL

®

Comfort. Safety. Performance.

NEW!

The CH-41ZCT Constant Temperature provides unparalleled comfort, safety and performance in one convenient package. Every unit includes a factorymounted ASSE 1017 mixing valve to ensure constant water temperature, greater hot water capacity and bacteria reduction to meet specific codes.

• Pre-Installed mixing valve with temperature gauge for constant temperature supply

• Ready to run design, no additional plumbing required

• Meets strict plumbing codes for bacteria control and scald prevention

• Available in Blue, Red or Gray to match popular boiler colors

• Includes optional homeowneractivated Limited Lifetime

protection plan

Available Colors:

Blue Red Gray

Tear Here Installer Section

ASSE 1017

Mixing Valve

Accurate

Temperature Gauge

Unions for

Easy Service

Relief Valve

Included

Reliable aquastat with simplified set points, including bacteria reduction zone

Factory-installed mixing assembly is piped and ready to install.

Accurate temperature gauge provides fast, simple adjustment.

Exclusive rotating outlet design provides wide range of installation options.

16

14

12

10

8

6

4

2

Tankless

Wall-Hung

Heater

Champion

CH-41ZCT

0

0 2 4 6 8

Flow Rate (GPM)

The CH-41ZCT is designed for minimal pressure drop. Compare a typical instantaneous heater's 10psi loss at only 5 GPM.

Comfort

Want to give your customers a consistent supply of hot water without the temperature swings? The

CH-41ZCT regulates hot and cold mixing to provide constant temperature at every faucet, all the time.

Plus, every Champion constant temperature heater includes a limited lifetime warranty protection plan so your customers will enjoy comfort and peace of mind.

Safety

Water heater safety is a hot topic, and the Champion

Constant Temperature was designed to meet stringent plumbing rules. The control includes simple markings to indicate the proper setting for bacteria reduction, while the ASSE 1017 mixing valve regulates output temperatures to meet scald prevention regulations.

Set the aquastat, adjust the mixing valve with the provided temperature gauge, engage the locking safety feature and you’re ready to go!

Performance

You’ve never seen a 41-gallon water heater with this kind of output. By storing water at a higher temperature and mixing it with cold water, the

Champion Constant Temperature improves your hot water draw by up to one-third. Compare the CH-

41ZCT to competitors' larger models; now that's big performance in a small package.

Specifications

Model:

CH-41ZCT

Capacity: 41 gallons

Height: 51"

Diameter: 22"

Shipping Wt: 128 lbs.

Cold Water inlet-nptm: 3 /

4

"

Mixed Water outlet-sweat: 3 /

4

"

Boiler Supply: 3 /

4

" nptm

Boiler Return: 3 /

4

" nptm

BOILER OUTPUT

(5 gpm input- to BoilerMate)

BTU/HR

40,000

60,000

80,000

100,000

1

FIRST-HOUR

RATING

(90°F rise)

GPH

75

102

129

156

2

CONTINUOUS

FLOW

(70°F rise steady state)

GPH

69

104

139

173

Corporate Headquarters

1400 Division Road, West Warwick, RI USA 02893

Telephone: 401-884-6300 • Fax: 401-884-5276

AMTROL Canada, Ltd.

275 Shoemaker Street, Kitchener, Ontario N2E 3B3

Telephone: 519-748-1138 • Fax: 519-748-4231 www.amtrol.com

AMTROL, AT logo, Champion, and BoilerMate are trademarks of AMTROL Inc. and its affiliates in the U.S. and elsewhere. All rights reserved. MC10169 (11/09)

The Champion Series

Constant Temperature by AMTROL

®

Comfort.

Safety.

Performance.

AMTROL, AT logo, Champion, and BoilerMate are trademarks of AMTROL Inc. and its affiliates in the U.S. and elsewhere. All rights reserved. MC10169 (11/09)

1-800-736-1149 www.amtrol.com

Model CH-41ZCT

Constant hot water in a safe, efficient package.

Comfort and efficiency are key elements of any hot water system. The Constant Temperature from AMTROL gives you both. Built-in temperature regulation provides a consistent supply of hot water every time, all the time; no more adjusting the shower handles to account for swings in water heater temperature. You’ll also get big performance in a small footprint, saving space while keeping up with high demands. Finally, every Constant Temperature unit integrates with your existing boiler. That means no additional gas lines and no extra flue venting for a clean, compact installation.

Your family’s safety is paramount, that’s why

AMTROL designed the Constant Temperature to protect you on two levels. First, every Constant

Temperature heater features a bacteria control mode that elevates internal water temperatures to guard against waterborne bacteria like

Legionella. In fact, the Constant Temperature is the only heater designed specifically to meet code requirements for bacteria reduction. Next, the built-in mixing valve tempers hot water to meet strict ASSE 1017 safety requirements, reducing the chances of scalding. Now you can enjoy hot water at a safe, predictable temperature everywhere in your home.

Installer Info

Company _________________________________________________

Contact __________________________________________________

Phone ____________________________________________________

1-800-736-1149 www.amtrol.com