Powerware® 5115 IU
Rackmount UPS
Product Focus
500-1500 VA
Product Snapshot
Power Rating:
500-1500 VA
Input/Output
Voltage:
Volts AC
120 & 230
Frequency:
Features
• 1U rack height conserves valuable rack space
• Unique chassis design adapts to rackmount, wall mount, side
cabinet (zero U), and bench top applications
• ABM® Technology significantly extends battery service life
• True sine wave output delivers smooth, continuous power
• Buck and Boost Automatic Voltage Regulation corrects incoming
voltage fluctuations
• Load segments enable scheduled shutdowns and extend backup
time for critical devices
• Hot-swappable batteries minimize downtime, simplify service
and extend service life of UPS
• Standard USB and RS232 serial ports extend communication
capacity
• X-Slot™ card communication options extend power management capability
• Power management software (included) ensures data integrity
50/60 Hz
(auto-sensing)
Configurations: Multi-mount
19 inch rack,
23 inch rack,
zero U, & wall
mount
The Powerware 5115
Rackmount UPS is the ideal
high-density power protection
solution ideal for servers, storage systems, network equipment and other critical devices.
The slim design and wide range
of installation possibilities make
the Powerware 5115 Rackmount
the most versatile UPS available. Occupying only 1U of rack
height, the 5115 conserves valuable rack space for other critical
devices while delivering powerful performance.
• Warranty:
-2-Year Limited Warranty
-10-Year Pro-Rated Warranty
-$150,000 Load Protection Guarantee
Unlike other UPSs that use
simulated sine wave, the
Powerware 5115 Rackmount
UPS provides pure sine wave
output during battery operation. As a result, the connected
devices continue to receive
high quality electrical input and
operate smoothly even during
power outages. In addition, this
unique UPS corrects incoming
voltage fluctuations to further
protect the connected equipment.
The Powerware 5115 Rackmount
UPS incorporates ABM
Technology, which doubles
battery service life, optimizes
recharge time for quick recovery
after power outages, and provides advanced warning at the
end of useful battery life. When
alarm notification indicates that
the end of battery life is near,
the batteries can be easily hotswapped without powering
down the connected load. Userfriendly design allows batteries
to be exchanged through the
front of the unit.
Simple plug-and-play operation
makes installing the Powerware
5115 RM UPS fast and easy.
The sophisticated communications are flexible, allowing
for local, network or remote
monitoring and management. This UPS arrives with the latest version of the Powerware Software Suite with complete cabling, which
provides power monitoring and unattended shutdown software.
The Powerware 5115 Rackmount UPS additionally comes standard
with a USB port, RS232 serial port and X-Slot communication bay
to provide further connectivity. In addition, the Network Transient
Protector isolates equipment from "back door" power surges traveling through network and phone lines.
With the Powerware 5115 Rackmount UPS, Powerware delivers a
best-in-class solution for critical network loads and the growing
need for reliable, ultra-compact power protection. All models are
manufactured to ISO 9001 standards and meet or exceed worldwide
specifications for safety, performance and excellence. Safeguarding
against power problems has never been easier.
Powerware 5115 Rackmount Special Features
Front and Rear Panels
Service Indicator (Red)
Power On Indicator (Green)
Load Segment 1 Indicator
On/Off Button
Load Segment 2 Indicator
Test/ Alarm Reset Button
On Battery Indicator (Yellow)
Overload Indicator (Red)
USB Communications Port communicates
with a USB-compliant computer when used
with included LanSafeTM power management
software
X-Slot Communications Bay
(Optional) X-Slot Cards allow the
UPS to communicate in a variety of
networking environments and with
different types of devices
6-ft. Power Cord
with 5-15 Plug
Site Wire Fault Indicator
offers instant notification
of site wiring problems
Network Transient Protector isolates your
modem, fax machine, telephone and other
communications equipment
1
Load Segments 1 & 2
are sets of receptacles
that can be controlled
by power management software,
providing an orderly
shutdown and startup
of your equipment
2
PW 5115 RM 120V Rear Panel Shown
RS232 Communications Port provides unattended shutdown and remote UPS monitoring capability when used
with included power management software and communication cable
4 UPS Protected
Outlets offer longlasting battery power
during power failures
and complete Series 5
power protection
Input and Output
Voltage Configuration
DIP Switches configure
the output voltage and
input voltage range
Mounting Configurations
The Powerware 5115 RM UPS packs the same technology of the tower model into a compact design for various applications. By limiting the
rack height (1U) of the UPS, the Powerware 5115 RM saves room for other critical equipment such as servers and disk arrays. Adaptable to
rackmount, wall mount, side-mount and bench-top applications, the Powerware 5115 RM is the most versatile UPS available. And all mounting accessories are included with every UPS.
19 inch and 23 inch rackmount applications
Side mount (zero-U) applications
Wall-mount applications
Battery Features and Runtimes
ABM Technology
Hot-Swappable Batteries
The batteries are easily accessible via the tool-free front access panel. The Powerware 5115 RM UPS
alows users to hot-swap batteries without powering down the connected load or removing the unit from
the rack. This makes it possible to extend the life of the UPS without returning the unit for service and
ensures connected equipment always stays up and running.
Data based upon tests performed
by an independent battery manufacturer.
Powerware 5115 RM shown with front cover removed and battery sliding out.
BATTERY RUNTIMES (IN MINUTES)
Load (VA/Watts)
PW5115 500 RM(i)
PW5115 750 RM(i)
PW5115 1000 RM(i)
PW5115 1500 RM(i)
200/130
19
37
41
76
300/190
11
25
29
58
500/320
5
13
15
28
600/400
9
12
21
750/520
6
8
16
900/600
6
11
1000/670
5
9
1200/800
8
1440/1000
5
Battery runtimes are approximate and may vary with equipment, configuration, battery age, temperature, etc.
Software and Connectivity Options
The industry’s most comprehensive software bundle, the
Powerware Software Suite, is included with every Powerware
5115 RM UPS.
ABM Technology significantly extends battery service
life. The lead-acid batteries
typically used in a UPS are
considered viable as long as
they can maintain backup
times of at least half that of
new batteries. The illustration above shows that batteries that are constantly
trickle charged (as are virtually all other UPSs on the
market today) reach the end
of their useful life in less
than half the time of batteries charged using ABM. This
unique process uses a proprietary three-stage charging technique that not only
doubles battery service life,
but also optimizes recharge
time and provides up to a
60-day advanced notification of the end of useful
battery life.
• Provides advanced power management
• Ensures data integrity
• Enables graceful, unattended shutdown
ConnectUPS-X Web/SNMP/xHub Card
• Remote monitoring and manageability through SNMP or Webbased networks
• Free updates on www.powerware.com
• Optional X-Slot Communication Cards
-ConnectUPSTM Web/SNMP Card adds control and monitoring
through SNMP/Web-based networks
-Relay Card adds integration to building management systems
-USB Card allows UPS to communicate with USB compliant
computers
Powerware Software Suite
Order Number
Description
103002974-5501
ConnectUPS-X Web/SNMP/xHub Card
05146508-5501
X-Slot USB Card
1018460
X-Slot Relay Card
POWERWARE 5115 RACKMOUNT 1U MODEL SELECTION GUIDE
Model Number 1
Power Rating
(VA / Watt)
Input
Connection
Output
Receptacles3
Dimensions
H x W x D (in / mm)4
Unit Weight
(lb/kg)
120 Vac Models2
PW5115 RM 500
500 / 320
5-15P
(4) 5-15R
1.73 x 17.3 x 22.8/445 x 440 x 578
35.2/15.9
PW5115 RM 750
750 / 520
5-15P
(4) 5-15R
1.73 x 17.3 x 22.8/445 x 440 x 578
41.4/18.8
PW5115 RM 1000
1000 / 670
5-15P
(4) 5-15R
1.73 x 17.3 x 22.8/445 x 440 x 578
41.4/18.8
PW5115 RM 1500
1440 / 1000
5-15P
(4) 5-15R
1.73 x 17.3 x 22.8/445 x 440 x 578
48.6/22.0
230 Vac Models2
PW5115 RM 500i
500 / 320
IEC-320-10A
(4) IEC-320-10A (C13)
1.73 x 17.3 x 22.8/445 x 440 x 578
35.2/15.9
PW5115 RM 750i
750 / 520
IEC-320-10A
(4) IEC-320-10A (C13)
1.73 x 17.3 x 22.8/445 x 440 x 578
41.4/18.8
PW5115 RM 1000i
1000 / 670
IEC-320-10A
(4) IEC-320-10A (C13)
1.73 x 17.3 x 22.8/445 x 440 x 578
41.4/18.8
PW5115 RM 1500i
1500 / 1000
IEC-320-10A
(4) IEC-320-10A (C13)
1.73 x 17.3 x 22.8/445 x 440 x 578
48.6/22.0
1. 50/60 automatic frequency selection. 2. 120V models are 110V, 120V, user-selectable. 230V models are 220V, 230V, 240V user-selectable. 3. divided into (2) Load Segments (receptacle groups).
4. Unit fits into standard 19 & 23 inch racks or can be wall-mounted and zero U rack-mounted. Mounting hardware supplied.
Technical Specifications1
Battery
Electrical Input
Nominal Voltage
Input voltage ranges
Battery Type
Sealed, lead-acid; maintenance free
120V models are 110V or 120V user-selec
table; 230V models are 220V, 230V or
240V user-selectable
Battery Run time
See Battery Run Time chart
Battery Replacement
Hot-swappable internal batteries
+\- 20% for nominal voltage at full load for
user-selectable voltages
Recharge Time
<3 hours to 90% usable capacity
Start-On-Battery
Allows start of UPS without utility input
Operating Frequency
50/60Hz, Auto-sensing
Frequency Range
46-65Hz
General
Diagnostics
Electrical Output
Self-test @ power up
Transfer Time
2-4 ms typical
On Utility Voltage Regulation
-10% to +6% of nominal
Dimensions and weights
See Model Selection Guide
On Battery voltage Regulation
±5% RMS
Overload (normal operation)
110% overload, shutdown after 3 minutes.
150% overload, shut down 10 cycles
Voltage Wave Shape (on battery) Sine Wave
Output protection
Electronic current limit
Safety Markings
Communications
User Interface
LED status display with AC power on, load
Group, Overload, On Battery and General
Alarm indicators, Site Wiring Fault Indicator
on rear panel for low volt models.
Audible Alarms
For various UPS alarm conditions, including:
On Battery, Low Battery, Overload, UPS fault
Network Transient Protector
UL 497 A, In/out jacks RJ45 (high voltage
models network protection) & RJ11
(low voltage models modem protection)
X-Slot Optional
ConnectUPS-X Web/SNMP/xHub Card;
Communication Cards
USB card ; X-Slot Relay card
Standard Communications
1 x RS-232 Serial Port & 1 x USB Port
Cable
6-foot communications cable included
Power Management Software
Powerware Software Suite CD-ROM
(bundled with UPS)
1. Specifications are subject to change without notice due to continuing product improvement programs.
UNITED STATES
8609 Six Forks Road
Raleigh, NC 27615 U.S.A.
Toll Free: 1.800.356.5794
or 919.872.3020
www.powerware.com
Environmental
CANADA
Ontario: 416.798.0112
LATIN AMERICA
Argentina: 54.11.4343.6323
Brazil: 55.11.3616.8500
México: 52.55.5488.5252
120V Models UL; cUL;
230V Models C-Tick; CE, TUV, cUL, UL
Safety Conformance
120V Models: UL 1778; UL497A; cUL
(CAN/CSA C22.2, No. 107.1)
230V Models: UL1778, UL 497A (data line
only); cUL (CAN/CSA C22.2, No. 107.1);
EN 50091-1-1 and IEC 60950
EMC Compliance
120V Models: FCC Part 15 subpart J
Class A, ICES-003;
230V Models: EN 50091-2. FCC Part 15
subpart J Class A , ICES-003
Operating Temperature
0 to 40º C (32 to 104º F)
Storage Temperature
-15 to 50º C (5 to 122º F)
Relative Humidity
5% to 95% non-condensing
Surge Suppression
ANSI C62.41 Category A
(formerly IEEE 587)
Audible Noise
Less than 40 dBA typical
Altitude
Up to 3000M (10,000 ft) without derating
EUROPE/MIDDLE EAST/AFRICA
Denmark: 45.3686.7910
Finland: 358.94.52.661
France: 33.1.6012.7400
Germany: 49.7841.666.0
Italy: 39.02.66.04.05.40
Norway: 47.23.03.65.50
Sweden: 46.8.598.940.00
United Kingdom: 44.1753.608.700
ASIA PACIFIC
Australia/NZ: 61.2.9878.5000
China: 86.21.6361.5599
HK/Korea/Taiwan: 852.2745.6682
India: 91.11.2649.9414 to 18
Singapore/SEA: 65.6829.8888
Powerware, ABM, X-Slot, and LanSafe
are trade names, trademarks and/or service
marks of Eaton Power Quality Corporation or
its subsidiearies and affiliates. All other trademarks are property of their respective owners.
© 2005 Eaton Corporation
All Rights Reserved
Printed in USA
5115RKFXA
April 2005
Download PDF